• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Υπολογισμός ηλεκτρομαγνητικών μεγεθών και πρόβλεψη συμπεριφοράς μιας σύγχρονης μηχανής με έκτυπους πόλους σε περιπτώσεις σφαλμάτων με τη χρήση της μεθόδου των πεπερασμένων στοιχείων / Electromagnetic magnitudes calculation and prediction of the behavior of a salient pole synchronous generetor during faults using the finite element method

Δάλλας, Στέφανος 31 August 2012 (has links)
Η παρούσα διδακτορική διατριβή πραγματεύεται τη λειτουργική συμπεριφορά μιας σύγχρονης μηχανής με έκτυπους πόλους κατά τη διάρκεια δύο ειδών σφαλμάτων, τα οποία παρουσιάζονται παρακάτω, για τις δύο συνθήκες σύνδεσης μίας σύγχρονης γεννήτριας με το δίκτυο. Ειδικότερα, μελετήθηκε η περίπτωση βραχυκυκλώματος στην τροφοδοσία του τυλίγματος διέγερσης της σύγχρονης μηχανής όταν είναι συνδεδεμένη σε ισχυρό δίκτυο και είτε ο αριθμός στροφών αυτής διατηρείται απόλυτα σταθερός, είτε ένας ελεγκτής τη συγκρατεί στο σύγχρονο αριθμό στροφών. Ακόμη διερευνήθηκε η περίπτωση εσωτερικού σφάλματος στο τύλιγμα του στάτη για τις δύο προαναφερθείσες περιπτώσεις. Υπολογίστηκαν και μελετήθηκαν η ηλεκτρομαγνητική ροπή και η μαγνητική επαγωγή κατά τη διάρκεια κάθε φαινομένου, καθώς επίσης τα ρεύματα σε δρομέα και στάτη συμπεριλαμβανομένων των ρευμάτων στον κλωβό απόσβεσης και του ρεύματος βραχυκύκλωσης σε τμήματα του τυλίγματος του στάτη. Αρχικά, περιγράφεται αναλυτικά ο τρόπος με τον οποίο μοντελοποιήθηκε η σύγχρονη γεννήτρια με έκτυπους πόλους, ενώ παράλληλα αναλύεται η μέθοδος με την οποία μοντελοποιήθηκαν τα σφάλματα σε στάτη και δρομέα και ο τρόπος με τον οποίο προσομοιώθηκε στο πρόγραμμα πεπερασμένων στοιχείων ο παραλληλισμός της μηχανής στο δίκτυο παροχής ηλεκτρικής ενέργειας. Στη συνέχεια, γίνεται αναφορά στον τρόπο με τον οποίο ορίζονται οι περιοχές του μοντέλου, οι εξισώσεις που επιλύει το πρόγραμμα πεπερασμένων στοιχείων για την εξαγωγή των αποτελεσμάτων, ο ορισμός των οριακών συνθηκών και τέλος περιγράφεται η εφαρμογή της μεθόδου πεπερασμένου στοιχείων που εφαρμόσθηκε στο συγκεκριμένο μοντέλο. Έπειτα προσομοιώθηκε η περίπτωση βραχυκυκλώματος στην τροφοδοσία του τυλίγματος διέγερσης, καθώς ο στάτης της σύγχρονης μηχανής είναι συνδεδεμένος σε ισχυρό δίκτυο με το δρομέα να στρέφεται με σταθερό αριθμό στροφών. Κατά τη διάρκεια του σφάλματος πραγματοποιείται λεπτομερής καταγραφή της μαγνητικής επαγωγής και της ηλεκτρομαγνητικής ροπής, καθώς και όλων των ρευμάτων στο τύλιγμα στάτη και δρομέα. Προκύπτουν χρήσιμα συμπεράσματα για τη συμπεριφορά της μηχανής σε όλη τη διάρκεια του σφάλματος και καταγράφονται τα ηλεκτρομαγνητικά μεγέθη και γίνεται αξιολόγηση της συμπεριφοράς της κατά τη διάρκεια αυτού του μεταβατικού φαινομένου. Ακόμη, εξετάζεται η ίδια περίπτωση σφάλματος στο τύλιγμα διέγερσης, αλλά ο αριθμός στροφών του δρομέα διατηρείται σταθερός μέσω ενός ελεγκτή στροφών. Παρατηρείται ότι η συμπεριφορά της μηχανής αλλά και όλα τα ηλεκτρομαγνητικά μεγέθη αυτής είναι τελείως διαφορετικά συγκρινόμενα με την προηγούμενη περίπτωση. Στη συνέχεια αυτής της διδακτορικής διατριβής εξετάζεται η συμπεριφορά της σύγχρονης μηχανής στην περίπτωση εσωτερικού βραχυκυκλώματος στο τύλιγμα του στάτη, καθώς είναι συνδεδεμένη σε ισχυρό δίκτυο με το δρομέα να στρέφεται με σταθερό αριθμό στροφών. Αναλυτικότερα, μελετώνται τα ρεύματα στο τύλιγμα του δρομέα καθώς και στο τύλιγμα του στάτη για βραχυκύκλωμα μεταξύ σπειρών που ανήκουν σε ίδια ή διαφορετική φάση. Υπολογίζεται το ρεύμα βραχυκύκλωσης και μελετάται ο τρόπος που επηρεάζει τα φασικά ρεύματα του στάτη τόσο ποσοτικά όσο και ποιοτικά. Επίσης, αναλύονται τα ρεύματα στον κλωβό απόσβεσης και μελετάται η συμπεριφορά τους κατά τη διάρκεια του βραχυκυκλώματος. Η εισαγωγή ελέγχου στροφών μεταβάλει τη συμπεριφορά της σύγχρονης γεννήτριας και υπολογίζονται αναλυτικά τα ηλεκτρομαγνητικά μεγέθη της σύγχρονης μηχανής προκύπτοντας συμπεράσματα για τον τρόπο με τον οποίο το βραχυκυκλωμένο τύλιγμα επηρεάζει τα μεγέθη αυτά, ενώ παράλληλα καθορίζεται ο ρόλος που έχουν οι φάσεις που συμμετέχουν στο βραχυκύκλωμα. Τέλος, γίνεται μια σύντομη σύγκριση για το πόσο επηρεάζει ο αριθμός σπειρών τη συμπεριφορά της σύγχρονης μηχανής στην περίπτωση σφάλματος στο στάτη κατά την περίπτωση κατά την οποία η μηχανή είναι συνδεδεμένη σε ισχυρό δίκτυο με σταθερό τον αριθμό στροφών του δρομέα. Πιο συγκεκριμένα, αναλύονται τα ρεύματα σε στάτη και δρομέα καθώς και η ηλεκτρομαγνητική ροπή, για τις περιπτώσεις που οι βραχυκυκλωμένες σπείρες ανήκουν στην ίδια και διαφορετική φάση αλλά με διαφορετικό αριθμό βραχυκυκλωμένων σπειρών για κάθε περίπτωση. Προκύπτει το συμπέρασμα ότι καθοριστικό ρόλο στη διαμόρφωση των ηλεκτρομαγνητικών μεγεθών κατά τη διάρκεια του σφάλματος έχει ο αριθμός των βραχυκυκλωμένων σπειρών, ανεξάρτητα από τον αριθμό των φάσεων που συμμετέχουν στο βραχυκύκλωμα. / This thesis deals with the functional behavior of a salient pole synchronous generator during two kinds of short-circuits. In particular, we studied the case of short circuit in the supply of the excitation winding of the synchronous machine when it is connected to an infinite bus and either the rotor speed was absolutely constant, or a simple PI- Controller maintained the synchronous speed equal to the synchronous. Additionally, the case of an internal fault in the stator winding for the two cases mentioned above was investigated. The electromagnetic torque and the magnetic flux density in each case were calculated and studied, as well as the stator and rotor currents, including the damper cage, and the short-circuit current in the faulty loop of the stator winding. Firstly, it is described in detail the way in which the salient pole synchronous generator was modeled and it is analyzed the method by which the faults are modeled in both stator and rotor and the way these faults were simulated, in the finite element program. Additionally, it is presented the way in how the areas of the model are defined, the equations that were solved through finite element software, in order to extract the results, the definition of the boundary conditions and finally it is described the finite element method, which was applied to this specific model. The case of a short circuit in the supply of the field winding while the stator of the synchronous machine is connected to the grid and the rotor speed is held constant and equal to the synchronous one, is examined. During this fault the magnetic flux, the electromagnetic torque and all the stator and rotor currents are measured in detail. Useful conclusions about the behavior of the machine throughout this kind of short-circuit were derived, all the electromagnetic magnitudes were recorded and an assessment of the generator behavior during this transient phenomenon is made. Similarly, the same type of fault is analyzed, but the speed of the rotor is maintained constant through a speed controller. It is observed that the behavior of the machine and all the electromagnetic magnitudes are quite different compared to the previous case. In this dissertation is examined the behavior of the hydrogenerator in the case of an inter-turn short circuit in the stator winding, while it is connected to the grid with a constant rotor speed. Specifically, it is examined the currents in the rotor and the stator winding for a short circuit between turns that belong to the same or to different phases. The short circuit current is calculated and it is presented the way that it affects quantitative and qualitative the stator phase currents. It is also analyzed the damper currents and it is studied their behavior during the short circuit. The speed controller alters the behavior of the synchronous generator and all the electromagnetic magnitudes of this machine are analytically calculated, resulting significant conclusions on how the faulty loop affects these quantities, while it is set out the role of the participating phases in this short-circuit. Finally, a brief comparison of the way that the number of the shorted turns affects the behavior of the simulated machine in the case of an inter-turn stator fault, while it is connected to the grid with a fixed number of the rotor revolutions. Specifically, it is analyzed the stator and rotor currents and the electromagnetic torque, for the cases that the short-circuited turns belong either to the same or to different phases, but with different number of shorted turns. It is concluded that a key role in determining the electromagnetic magnitudes during this fault has the number of the short-circuited turns and not the number of the phases that are involved in the short circuit.
2

Detection of stator interturn fault of synchronous machine by rotor current analysis : A SIMULATION APPROACH

Rabbi, Ata-E January 2016 (has links)
One of the major electrical faults of synchronous machines is an interturn short circuit in the stator winding, due to winding insulation failure. A synchronous machine is designed to have electrical and mechanical symmetry in the stator and rotor. An interturn fault in a synchronous machine damages the symmetrical property, thereby inducing abnormal symptoms like varying torque, mechanical vibration, and deviation of stator and rotor terminal currents from their usual waveform. This last symptom is what is studied in this thesis, as an indicator of the presence of an interturn fault. An interturn fault during machine operation can lead to a catastrophic machine failure and consequent long outage, unless it is rapidly detected and the machine shut down. Prevention of such outages is an important concern for machine owners and power system operators. That is why early detection of interturn faults is desirable to prevent such machine failure. Several external sensors can be implemented to detect such interturn fault, which is costly. That is why it is desirable if the interturn fault can be detected by analyzing the measured currents that already are available to a protective relay. In this thesis a simulation approach is presented to observe the pattern and frequency spectrum of rotor field current in presence of a stator inter turn fault. All simulations have been performed using Matlab-based programs written during this thesis work in the Electromagnetic department (ETK) in KTH. The outcome of the thesis is that in the presence of an interturn fault in the stator, several even harmonic components are found in the frequency spectrum of the rotor field current. The presence of these harmonics is not a definitive sign of an interturn fault, as almost the same even harmonics are found in the rotor field current if the stator winding asymmetry is taken into account. / En av de största elektriska felen i synkronmaskiner är en kortslutning mellan varv i statorlindningen, på grund av skadad lindningsisolering. En synkronmaskins konstruktion ger elektrisk och mekanisk symmetri i statorn och rotorn vilket ger en hög effektivitet. Ett varvfel i statorn skadar symmetrin och inducerar onormalt stora strömmarvilket leder till ett tidsvarierande vridmoment, mekanisk vibration, och onormala vågformer av strömmarna vid statorns och rotorns poler. Varvfel under maskinens drift kan snabbt orsaka stora skador, med följd av långa avbrottstider. Förebyggande av sådana avbrott är viktig hos maskinägare och systemansvariga. Därför är snabb detektering av sådana fel, och urdrifttagning av maskinen önskvärd för att minska skadan. Däremot ska detekteringen ha låg sannolikhet att lösa ut i onödan, av annat skäl. Externa sensorer kan användas för att upptäcka sådana fel, men det är tydligt önskvärt om detekteringen kan göras genom att analysera strömmarna som redan mäts av skyddsreläer för synkronmaskiner. I denna avhandling presenteras en metod för att simulera och observera mönster och frekvensspektrum av rotors magnetiseringsström i fall där statorn har varvfel, samt i andra fall som måste kunna skiljas från varvfel. Alla simuleringar har utförts med Matlab hos avdelningen för Elektroteknisk teori och konstruktion (ETK) i Skolan för Elektro- och systemteknik (EES) på KTH.
3

Algoritmy monitorování a diagnostiky pohonů se synchronními motory / Monitoring and Diagnosis Algorithms for Synchronous Motor Drives

Otava, Lukáš January 2021 (has links)
Permanent magnet synchronous machine drives are used more often. Although, synchronous machines drive also suffer from possible faults. This thesis is focused on the detection of the three-phase synchronous motor winding faults and the detection of the drive control loop sensors' faults. Firstly, a model of the faulty winding of the motor is presented. Effects of the inter-turn short fault were analyzed. The model was experimentally verified by fault emulation on the test bench with an industrial synchronous motor. Inter-turn short fault detection algorithms are summarized. Three existing conventional winding fault methods based on signal processing of the stator voltage and stator current residuals were verified. Three new winding fault detection methods were developed by the author. These methods use a modified motor model and the extended Kalman filter state estimator. Practical implementation of the algorithms on a microcontroller is described and experimental results show the performance of the presented algorithms in different scenarios on test bench measurements. Highly related motor control loop sensors fault detection algorithms are also described. These algorithms are complementary to winding fault algorithms. The decision mechanism integrates outputs of sensor and winding fault detection algorithms and provides an overall drive fault diagnosis concept.

Page generated in 0.0556 seconds