71 |
Caracterização dosimétrica do BeO em feixes de radiodiagnóstico convencional, mamografia e tomografia computadorizada, pelas técnicas de termoluminescência e luminescência opticamente estimulada / Dosimetric characterization of BeO in standard beams of conventional diagnostic radiology, mammography and computed tomography, by the thermoluminescence and optically stimulated luminescence techniquesAlgarve, Fábio Junqueira 18 August 2017 (has links)
A radiação ionizante é amplamente utilizada em diversas áreas na indústria e na medicina. No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, abrangendo assim um grande intervalo de doses de diferentes tipos de radiações. Para certificar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que atendam aos diferentes tipos de radiações. Neste trabalho foi realizado um estudo das características dosimétricas de amostras de BeO em feixes padronizados de radiodiagnóstico convencional, mamografia e tomografia computadorizada, utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) e propondo um sistema adequado para sua utilização em dosimetria de feixes. Os principais resultados obtidos foram: alta sensibilidade à luz branca durante a irradiação, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), parâmetros cinéticos correspondentes aos valores obtidos em todos os métodos testados, sem fading dentro do período estudado para ambas as técnicas. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria da radiação X, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Assim, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico convencional, mamografia e tomografia computadorizada. / The ionizing radiation is widely used in several areas in industry and medicine. In the field of medicine, the ionizing radiation is used both for therapeutic purposes and for diagnostic purposes, thus covering a wide range of doses of different types of radiation. To certify that the goal of practice is being achieved detailed studies of detectors and devices that respond to different types of radiation are required. In this work, a study of dosimetric characteristics of BeO samples was performed in standard beams of conventional diagnostic radiology, mammography and computed tomography, using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL), and proposing a suitable system for its use in beam dosimetry. The main results obtained were: high sensitivity to white light during the irradiation, good reproducibility of responses TL and OSL (coefficients of variation of less than 5%), and kinetics parameters corresponding to the values obtained in all of the tested methods, without fading within the observed period for both techniques. The dosimetric characteristics obtained in this work show the possibility of application of BeO samples for dosimetry of X radiation, considering the tested dose interval, by the TL and OSL techniques. Thus, the BeO samples presented potential use for dosimetry of conventional diagnostic radiology, mammography and computed tomography beams.
|
72 |
Espectroscopia entre 10 e 4000 centímetros pot. Aplicação aos modos vibracionais da sodalita natural brasileira / The influence of capture centers on the dielectric relaxation of KI:M++ crystalsZilio, Sergio Carlos 20 April 1983 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl-. Os novos picos de relaxação, atribuídos à presença do Cl- na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente. Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl- e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl-ions. The new relaxation peak attributed to the presence of the Cl- in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one. A model for the trapping of the divalent ions by the Cl- is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
|
73 |
Metodologia dosimétrica para extremidades em indivíduos ocupacionalmente expostos à radiação beta por meio da técnica de luminescência opticamente estimulada / Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence techniquePinto, Teresa Cristina Nathan Outeiro 27 July 2010 (has links)
Uma metodologia dosimétrica foi estabelecida, para determinação das doses recebidas em extremidades por indivíduos ocupacionalmente expostos à radiação beta, com detectores de Al2O3:C e sistema leitor microStar, da Landauer, associados à técnica de luminescência opticamente estimulada (OSL). As principais etapas do trabalho foram: caracterização do material dosimétrico Al2O3:C utilizando a técnica de OSL; estabelecimento de um método para avaliação de dose em extremidades; determinação de taxas de dose de fontes de radiação beta; aplicação do método estabelecido em um teste prático com indivíduos ocupacionalmente expostos à radiação beta durante uma simulação de procedimento de calibração de aplicadores clínicos; validação do método desenvolvido por meio de comparação das doses obtidas no teste prático pela técnica de OSL com doses obtidas pela técnica de TL. Os resultados mostram que os detectores de Al2O3:C e a técnica de OSL podem ser utilizados em monitoração individual de extremidades e radiação beta. / A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al2O3:C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al2O3:C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al2O3:C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation.
|
74 |
Luminescência opticamente estimulada com aplicações em radioterapia: dependência da dose absorvida e da energia de fótons produzidos em aceleradores clínicos e Microtron - IFUSP / Optically stimulated luminescence with applications in radiotherapy: dependence of absorbed dose and photon energy produced on clinical accelerators and Microtron - IFUSPFreitas, Carlos Eduardo 28 April 2017 (has links)
Atualmente a utilização de fótons de raios X e gama na Medicina (radiodiagnóstico e radioterapia) gerou a necessidade do conhecimento da dose absorvida nos tecidos dos pacientes. Para isso, utiliza-se detectores com diversas funcionalidades a fim de conhecer a deposição de energia. Para ser possível a utilização destes materiais, é necessário caracterizá-los tanto quanto à resposta em função da dose absorvida, quanto à dependência com a energia. Neste trabalho foi estudada a dependência energética da resposta OSL dos dosímetros compostos por BeO e Al2O3 em feixes de raios X convencional com espectro largo, feixes de raios X de aceleradores clínicos e do acelerador Microtron do Instituto de Física da USP e fontes gama de Cs-137 e Co-60, em uma faixa de doses desde centenas de mGy até aproximadamente 2 Gy. Foram utilizadas em conjunto simulações em Monte Carlo com o código PENELOPE, que simula o transporte de fótons e elétrons na matéria, a fim de conhecer a deposição de energia nos materiais. Os espectros utilizados nas simulações foram validados através da comparação das características dos feixes tais como a deposição de dose com a profundidade, camada semirredutora, energia média e resolução espectral. Utilizando um sistema de varredura por câmara de ionização controlado remotamente, foi estudada a distribuição de doses no campo de irradiação para definir uma região de irradiação com dose uniforme para pode realizar a irradiação de um conjunto de dosímetros simultaneamente. Foram encontrados valores do fator de dependência energética experimental para os feixes mais energéticos (Co-60, Microtron 5 MeV e aceleradores clínicos de 6 e 15 MeV), com desvio menor que 3% para o Al2O3 e 5% para o BeO, indicando independência com a energia do feixe de irradiação. Já nos feixes de baixa energia, os fatores de dependência energética relativos à energia do Co-60 para o Al2O3 foram de 1,68 e 1,42, e, para o BeO, de 0,78 e 0,90 para os feixes W150 e W200 respectivamente. Estes valores indicam que, nesta faixa de energia, a resposta OSL depende mais fortemente da energia do feixe. As simulações em Monte Carlo feitas para os fatores de dependência energética se mostraram bem consistentes com os valores experimentais para o BeO em toda faixa de energia e para o Al2O3, excetuando-se os feixes de baixa energia, possivelmente pelo não completo conhecimento de todos os elementos constituintes do dosímetro empregado (fita de Luxel®). Quanto às curvas de emissão OSL para as diferentes energias de irradiação, foi observado que o sinal decai mais rápido quanto mais elevada é a energia média do feixe para o BeO. Para o Al2O3, o efeito foi mais sutil e oposto. Os estudos do feixe do Microtron mostraram que, desde que a corrente seja monitorada durante as irradiações para posterior correção da dose, é possível realizar estudos utilizando um feixe de fótons de Bremsstrahlung produzido com alvo externo e energias médias (simuladas e ainda não validadas experimentalmente) próximas às energias das fontes gama de Cs-137 e Co-60. Os resultados experimentais para as respostas OSL dos dois materiais foram compatíveis com as simulações. / Nowadays the use of X and gamma-ray photons in Medicine (radiodiology and radiotherapy) has generated the necessity of knowing the absorbed dose to the tissues of patients. For this purpose, detectors with diverse functionalities are used to know the energy deposition. To make possible the use of these materials, it is necessary to characterize the dose response, as well as the energy dependence of the response. In this work the energy dependence of the OSL response of the BeO and Al2O3 dosimeters was studied for conventional X-ray beams with wide energy spectrum, X-ray beams from clinical accelerators and from the Microtron accelerator of the Institute of Physics (University of São Paulo), and for gamma sources of Cs-137 and Co-60, in a dose range from hundreds of mGy to about 2 Gy. Monte Carlo simulations were used with the PENELOPE code, which simulates the photons and electrons transport of in the matter, to know the energy deposition in the materials. The energy spectra used in simulations were validated by comparison with beam characteristics such as depth dose deposition, half-value layer, mean energy and spectral resolution. Using a remotely controlled ionization chamber scanning system, the dose distribution within the irradiation field was evaluated to define a uniform dose region for irradiation or a set of dosimeters simultaneously. Experimental energy dependence factor values were obtained for the high-energy beams (Co-60, Microtron 5 MeV, and clinical accelerators of 6 and 15 MeV), with a deviation of less than 3% for Al2O3 and 5% for BeO, indicating independence with the beam energy. For the low-energy X-ray beams, the energy dependence factors, relative to the Co-60 energy, for Al2O3 were 1.68 and 1.42, and, for BeO, 0.78 and 0.90 for W150 and W200 beams respectively. These values indicate that, in this energy range, the OSL response depends on beam energy. Monte Carlo simulations for the energy dependence factors were consistent with experimental values for the BeO in entire energy range and for the Al2O3, with the exception of low energy beams, possibly due to the incomplete knowledge of all the elements that constitute the Luxel®. As for the shape of OSL emission curves for the different irradiation energies, it was observed that the signal decays faster the higher is the average beam energy for BeO. For Al2O3, the effect was more subtle and opposite. The Microtron beam scanning has shown that, as long as the current is monitored during irradiation for further dose-rate correction, it is possible to carry out studies using a beam of Bremsstrahlung photons produced with external target and mean energies (simulated but still not validated experimentally) close to the energies of the Cs-137 and Co-60 sources. The experimental results for the OSL responses of both materials were compatible with simulations.
|
75 |
Síntese e caracterização de elemento sensor de matriz KAISi3O8, dopadas com Mn ou Gd, obtidos pela técnica sol-gel, visando a aplicação em dosimetria das radiações ionizantes por termoluminescência e luminescência opticamente estimulada. / Synthesis and caracterization of sensor element of kalSi3O8 matrix, doped with mn and gd, obtained by sol-gel method, for application in ionizing radiation dosimetry by thermoluminescence and optically stimulated luminescence.Pires, Elcio Liberato 12 November 2010 (has links)
Neste trabalho, estudou-se as propriedades termoluminescentes e fotoluminescentes (em processo anti-Stokes), além de algumas propriedades químicas e físicas, de amostras sintéticas de KAlSi3O8, dopadas com Mn ou Gd, obtidas por meio da técnica sol-gel. O objetivo principal do estudo foi a obtenção de um novo material, com possibilidades reais de aplicação em dosimetria das radiações ionizantes, como elemento sensor de dosímetros luminescentes. As amostras foram obtidas e trabalhadas na forma de pós com tamanho médio de partícula em 600 nm e suas estruturas composta por uma matriz amorfa e com presença de nano partículas, presente apenas nas amostras dopadas. Os resultados de EPR mostraram que os dopantes incorporaram na matriz sob a valência de Mn2+ e Gd3+ respectivamente. As curvas de emissão TL apresentaram formatos semelhantes para todas as regiões estudadas, com a presença de um pico principal de intensidade alta e reprodutível em torno de 170°C. As curvas de decaimento da LOE da amostra não dopada e dopada com Mn exibiram um decaimento total da luminescência para 40 s de estimulação centrada em 470 nm; por outro lado, a amostra dopada com Gd, exibiu um rápido decaimento da LOE (aproximadamente 71,4 % da intensidade inicial), para os primeiros 40 s de estimulação, seguida por um decaimento mais lento e persistente para o restante do período de estimulação, o que indica claramente a presença de duas componentes de decaimento. As amostras dopadas com Mn apresentaram emissão TL mais intensa em torno 570 nm, sendo mais eficientes para os estudos de TL no VIS; enquanto que, as dopadas com Gd, exibiram emissão mais intensa em 470 nm, porém, devido ao formato dos sinais (presença de um único pico aparente), mostraram-se melhor para os estudos de LOE e TL no UV. As amostras dopadas com 0,5% e 8% em mol de Mn e Gd, respectivamente, apresentaram os sinais luminescentes mais intensos, tanto para LOE quanto para TL. No estudo da dependência energética para diferentes energias de raios-X, o tipo de dopante influenciou no padrão de resposta obtido, tendo sido observado um decréscimo da intensidade luminescente com o aumento da energia para a amostra dopada com Mn; para a amostra não dopada e dopada com Gd, não se observou um padrão de decréscimo ou aumento da intensidade com a energia. As curvas de calibração foram ajustadas por meio de retas com grau de confiabilidade alto (fator R2 próximo a 1), e as menores doses detectáveis variaram entre 20 e 60 mGy aproximadamente. Todas as amostras apresentaram perdas consideráveis de intensidade luminescente com o passar do tempo após irradiação, e que foi de aproximadamente 80%, em média, para os 10 primeiros dias. Concluiu-se que, a princípio, os materiais têm maior possibilidade de aplicação na dosimetria em tempo real do que na dosimetria convencional ou passiva por TLDs, devido a sua alta resposta luminescente. Contudo, estudos futuros a respeito de tratamento térmico prévio, podem viabilizá-los a esta última aplicação. Com relação ao campo de aplicação, sugere-se a dosimetria ambiental, devido aos valores Z obtidos, que estão mais próximos do dos materiais que compões rochas e sedimentos. / In this work the thermoluminescent and photoluminescent properties (in the anti-Stokes process), and some other chemical and physical properties of KAlSi3O8 synthetic samples, doped with Mn or Gd, obtained by sol-gel method, were studied. The main goal of this study was to obtain a new material, with real possibility of application in ionizing radiation dosimetry as sensor element in luminescent dosimeters. The obtained samples were composed of powders with average particle size around 600 nm and they structures were composed of an amorphous matrix with presence of nanoparticles, observed only in the doped samples. The EPR results showed that the dopants incorporated in the matrix in the Mn2+ and Gd3+ valences, respectively. The TL glow curves exhibited a similar pattern for all the studied regions, composed of a main high-intensity and reproducible peak around 170 °C. The OSL shine-down curves for the undoped and Mn doped samples exhibited a total decay of luminescence for 40 s of stimulation centered at 470 nm; on the other hand, Gd doped sample exhibited an quick OSL decay (approximately 71.4 % of the initial intensity), for the first 40 s of stimulation, followed by a slower and more persistent decay, which clearly indicates the presence of two decay components. Mn doped samples showed the highest TL emission around 570 nm, being more efficient for the TL studies in the VIS, while the Gd doped samples exhibited the highest emission at 470 nm; however, due to the obtained curve pattern (with an apparent single peak), they had shown more efficient results for the applications in the UV. The samples doped with 0.5 and 8 mol% of Mn and Gd, respectively, showed the highest luminescent response improvement for OSL and TL. Energetic dependence on different X-rays energies study showed that the dopants changed the obtained response pattern. The Mn doped sample exhibited a decrease in luminescent response, while the Gd and the undoped samples do not show a pattern of decrease or increase in luminescence. The calibration curves were fitted by straight lines with high reliability degree (R2 near to 1), and the lowest detectable doses were between 20 and 60 mGy. All the samples exhibited considerable losses in luminescent intensity with the time after irradiation (about 80% for the firsts 10 days). From the results it was concluded that the studied materials are more applicable to real time than to passive TLD dosimetry, due to their high luminescent response. However, studies about previous heating treatment could make them feasible for the last application. The use of these materials in environmental dosimetry is suggested due to the obtained Z values, which are closer to those which form rocks and sediments.
|
76 |
Influência de centros de captura na relaxação dielétrica de cristais de Ki:M++. / The influence of capture centers on the dielectric relaxation of Ki:M ++.Zilio, Sergio Carlos 16 August 1976 (has links)
Encontrou-se que a relaxação dielétrica dos dipolos impureza-vacância em KI dopado com pequenas quantidades de KCl é extremamente diferente da relaxação dielétrica na matriz KI não contendo íons Cl‾.Os novos picos de relaxação, atribuídos à presença do Cl‾ na vizinhança imediata do íon divalente, tem um tempo de relaxação 103 vezes menor que o normal na temperatura ambiente.Foi proposto um modelo para o aprisionamento dos íons divalentes pelo Cl‾ e estudado a influência dos raios atômicos do divalente e do anion estranho neste processo de aprisionamento. / The dielectric relaxation due to I-V dipoles in KI doped with small amounts of KCl was found to be strongly different than in KI crystals not containing Cl‾.The new relaxation peak attributed to the presence of the Cl‾ in the close neighborhood of the divalent ion has a relax¬ation time 103 greater than the normal one.A model for the trapping of the divalent ions by the Cl‾ is proposed. The influence of atomic radius of the divalent and the impurity anion is discussed.
|
77 |
Efficacité antivirale des différents types d'interférons sur la multiplication du virus BKMartin, Élodie 03 October 2017 (has links)
Le polyomavirus humain BK (virus BK) établit une infection persistante asymptomatique dans les voies rénales de 80% de la population humaine. Chez les patients transplantés, la réactivation du virus BK est à l'origine de néphropathies et de cystites hémorragiques. L'augmentation des pathologies associées au virus BK en même temps que l'utilisation de traitements immunosuppresseurs de plus en plus puissants souligne un lien étroit entre la réponse immunitaire de l'hôte et la réactivation virale. Cependant la réponse immune à l'infection par le virus BK, en particulier le rôle des cytokines antivirales dans le contrôle de l'infection est peu documentée. Ici, nous avons étudié l'efficacité antivirale des interférons (IFN) sur la multiplication du virus BK. Nous avons testé les IFN-alpha, lambda et gamma sur la souche Dunlop du virus BK dans les cellules Véro et MRC 5. L'IFN-gamma inhibe de façon dose-dépendante la transcription virale de la région précoce et de la région tardive ainsi que l'expression de la protéine virale VP1. Un moindre effet antiviral a été observé avec l'IFN-alpha et l'IFN lambda. Ces résultats sont associés à une phosphorylation prolongée de STAT 1 avec l'IFN-gamma, non retrouvée avec l'IFN-alpha et lambda. La différence d'efficacité entre ces trois types d'IFN suggère que certaines protéines induites seulement par l'IFN-gamma ont un effet antiviral dans l'infection par le virus BK. L'analyse transcriptionnelle révèle neuf protéines qui pourraient être impliquées dans cet effet antiviral spécifique. Parmi elles, nous avons étudié l'effet antiviral de l'indoleamine 2,3-dioxygénase (IDO) et les protéines de liaison au guanylate (GBP ou guanylate binding protéines), GBP1 et GBP2, sur le virus BK. Nos résultats montrent que GBP1 et GBP2 mais pas IDO contribuent à l'activité antivirale de l'IFN-gamma sur le virus BK. Trouver le mécanisme d'action de ces protéines antivirales induites par l'IFN pourrait nous aider à développer une stratégie thérapeutique / The human polyomavirus BK (BK virus) establishes an asymptomatic persistent infection in the urinary tract of 80% of the human population. In transplant recipients, reactivation of the BK virus infection is the cause of nephropathy and hemorrhagic cystitis. Diseases associated with BK virus infections are increasing at the same time as potent immunosuppressive therapies are developing. This highlights the importance of components of the immune system in controlling viral reactivation. However, the immune response to the BK virus, particularly the role of antiviral cytokines in infection control, is poorly documented. Here, we investigated the antiviral efficacy of interferons (IFN) on the BK virus multiplication. We tested IFN-alpha, lambda and gamma on the Dunlop strain of BK virus in Vero cells and MRC 5 cells. Treatment with IFN-gamma inhibited the expression of the viral protein VP1 in a dose dependent manner and decreased the expression of the early and late viral transcripts. A weaker antiviral effect was observed with IFN-alpha and IFN-lambda. These results are associated with a prolonged STAT1 phosphorylation with IFN-gamma but not with IFN-alpha and lambda. The difference of efficacy between these three types of interferon suggests that some interferon induced proteins only produced by IFN-gamma had an antiviral effect on BK virus infection. Transcriptomic analysis reveals that nine proteins could be involved in this specific antiviral effect. Among them, we selected and investigated the antiviral effect of indoleamine 2,3-dioxygenase (IDO) and guanylate binding protein 1 and 2 (GBP1 and GBP2) on the BK virus. Our results suggest that GBP1 and GBP2 but not IDO contribute to the antiviral activity of IFN-gamma on the BK virus. Finding the action mechanism of these IFN gamma induced antiviral proteins could help to develop a therapeutic strategy
|
78 |
Sistema automatizado de medidas TSC em plataforma GUI / Automated system for TSC measurements in GUI platformBruno, Odemir Martinez 24 August 1995 (has links)
Neste trabalho desenvolvemos um método de controle e aquisição de dados, particularmente aplicado a medidas de correntes termoestimuladas (TSC), mas que podem ser estendidas a sistemas semelhantes. O sistema automatizado de medidas TSC em plataforma GUI, foi implementado de modo a realizar o controle da temperatura de uma estufa, de forma que seja possível gerar rampas lineares com taxas programáveis, e também a leitura de sinais analógicos referentes ao sistema, como corrente e temperatura, e processar os sinais obtendo como resultado curvas gráficas (sinais processados em função do tempo). Os resultados são armazenados e podem ser exibidos, ou impressos e transferidos para o padrão de arquivo de entrada de outros aplicativos. Os dados são obtidos em tempo real e o sistema utiliza conceitos da tecnologia GUI, onde provemos um estudo desta, gerando janelas com interação orientada a eventos e uma interface gráfica com o usuário bastante interativa. O sistema faz uso de microcomputador padrão IBM PC AT e utiliza o MS-Windows 3.1 como plataforma GUI (\"GraphicsUser Interface\"). / A method for control and data acquisition using GUI environment, applied to thermal and electrical measurements was developed. The method was specifically applied to thermal stimulated current (TSC), but it can be extended to similar systems. The GUI - based automated TSC system maked possible the accurate control of the oven temperature, at different heating rates. This system performs the data acquisition of analogic signals (current and temperature, for instance), and those signals are processed generating functions of time and/or temperature (TSC curves, for example). Stored results can be displayed, printed, as well as transferred to files, which are compatible to standard applicative for data treatment. Data are obtained in real time and the system uses GUI concepts, which are extensively studied in this work, generating events oriented windows and a user-friendly graphical interface. The system configuration consists of an IBM PC AT microcomputer and the MS-Windows 3.1 is used as the GUI environment.
|
79 |
Estudo da luminescência de cristais de quartzo naturais e artificiais crescidos pelo método sol-gel. / Study of the luminescence of natural and artificial quartz crystals grown by the sol-gel method.Tudela, Diego Renan Giglioti 28 November 2018 (has links)
Este trabalho foi dividido em duas grandes partes principais, a primeira relacionada ao estudo da luminescência de quatro espécimes de quartzo naturais brasileiros (verde, hialino, rosa e azul) e a segunda trata da confecção e caracterização de amostras sintéticas, baseadas na estrutura do SiO2, obtidas pelo método de sol-gel para fins de dosimetria das radiações ionizantes ambientais. Através da Análise por Ativação com Nêutrons Instrumental (AANI) e Fluorescência de Raios X por Reflexão Total (TXRF), foram determinadas as principais impurezas em concentrações maiores, menores e traços de forma quantitativa e qualitativa, respectivamente. Os espécimes verde e azul foram os que apresentaram as maiores quantidades de impurezas, incluindo metais e elementos terras raras, enquanto que o hialino e rosa são praticamente puros. Suas emissões de TL foram distintas, em termos de intensidade e posição dos picos. Testes de recuperação de dose por luminescência opticamente estimulada (LOE), através dos protocolos de alíquotas múltiplas (MAR) e única (SAR) com doses regenerativas, foram realizados e o espécime verde foi o único que apresentou resultados satisfatórios nesses testes, seguido do azul. Os cristais hialino e rosa apresentaram saturação e curva de crescimento fora da linearidade, onde o primeiro mostrou o efeito da fototransferência para a maioria das análises de SAR. Como os cristais verde e hialino apresentaram resultados opostos, em termos de quantidades de impurezas e emissões luminescentes, foi realizado um tratamento térmico em alta temperatura (1600 °C) para observar o efeito da mudança de fase (cristobalita) nas suas emissões luminescente. Ajustes teóricos das curvas de emissão de LOE contínua, linearmente modulada e TL mostraram que elas seguem o modelo teórico de cinéticas de ordens gerais. Na segunda parte deste trabalho, 32 amostras artificiais, do polimorfo de alta temperatura do quartzo, a cristobalita, foram sintetizadas com diferentes quantidades e tipos de dopantes, baseado nas impurezas determinadas no quartzo verde, utilizando duas rampas de aquecimento nas calcinações (3 e 15 °C/min). Essa parte do trabalho teve como finalidade o estudo do efeito do Fe na emissão luminescente das amostras sintéticas, a reprodução de uma das amostras naturais e produção e caracterização de dosímetros para radiações ionizantes ambientais. A utilização das duas rampas de aquecimento na emissão de TL, de forma geral, não desempenhou papel determinante na intensidade dos picos de altas temperaturas. Já na LOE foi observado que as amostras calcinadas com a rampa de maior temperatura apresentaram resposta à dose mais elevadas. O Fe como dopante em maior quantidade atuou como um inibidor de luminescência tanto na TL quanto na LOE. Uma amostra com características qualitativas semelhante ao quartzo verde, na fase da cristobalita, foi obtida com relativo sucesso utilizando como dopante todas as doze principais impurezas adquiridas para realização deste projeto. Quatro amostras foram sintetizadas com diferentes tipos e quantidades de dopantes para aplicação em dosimetria das radiações. Somente uma destas apresentou resposta linear às doses de radiação utilizando estimulação térmica (TL), cuja mínima dose de detecção (MDD) foi de 172 µGy. Utilizando estimulação óptica (LOE), duas amostras apresentaram comportamento linear com as doses de radiação, em que valores de MDD de ~440 µGy e 405 µGy foram obtidos. / This work was divided into two major parts, the first one related to the study of the luminescence of four Brazilian natural quartz specimens (green, hyaline, pink and blue) and the second one deals with the confection and characterization of synthetic samples, based on SiO2 structure, obtained by means of sol-gel method to environmental ionizing radiation dosimetry. Through Instrumental Neutron Activation Analysis (INAA) and Total Reflection X-ray Fluorescence (TXRF), the main impurities in major, minor and trace concentrations were determined quantitative and qualitatively respectively. The green and blue specimens presented the highest amounts of impurities, including metals and rare earth elements, whereas hyaline and pink are practically pure. Their TL emissions were distinct, in terms of intensity and peak position. OSL dose recovery tests, using multiple (MAR) and single aliquots regeneration (SAR) dose protocols were performed and the green specimen was the only one which presented satisfactory results in these tests, followed by blue. The hyaline and pink crystals showed saturation and growth curve out of linearity, where the first one showed the effect of phototransference for most SAR analysis. As green and hyaline crystals presented opposite results, in terms of impurities quantities and luminescent emissions, a high temperature (1600 °C) heat treatment was performed to observe the effect of the phase change (cristobalite) on its luminescent emissions. Theoretical adjustments of the CW-OSL, LM-OSL and TL emission curves showed that they follow the theoretical model of general order kinetics. In the second part of this work, 32 artificial samples of the high temperature polymorph of the quartz, cristobalite, were synthesized with different amounts and types of dopants, based on impurities determined in green quartz, making use of two heating rates in the calcinations (3 and 15 °C/min). This part of the work had as purpose the study of the effect of Fe in the luminescent emission of the synthetic samples, the reproduction of one of the natural samples and production and characterization of dosimeters for environmental ionizing radiation. The use of the two heating rates in TL emission, in general, did not play a determining role in the intensity of the high temperature peaks. In the OSL, it was observed that samples calcined with higher heating rate temperature showed higher response to dose. The Fe as a dopant in greater quantities acted as a quencher of luminescence both in TL and OSL. A sample with qualitative characteristics similar to the green quartz, in the cristobalite phase, was obtained with relative success using as dopants all the twelve main impurities acquired for this project. Four samples were synthesized with different types and amounts of dopants for application in ionizing radiation dosimetry. Only one of these showed a linear response to radiation doses using thermal stimulation (TL), with a minimum detectable dose (MDD) of 172 µGy. Using optical stimulation (OSL), two samples showed linear behavior with radiation doses, in which MDD values of ~440 µGy and 405 µGy were obtained.
|
80 |
Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele - TSI / Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSIAlmeida, Shirlane Barbosa de 11 April 2017 (has links)
A dosimetria in vivo têm se tornado um papel importante para o tratamento da irradiação total da pele dentro de um rigoroso programa de garantia de qualidade que deve ser parte integrante nos departamentos radioterápicos. A dosimetria em TSI é difícil, devido à complexidade do tratamento em avaliar a uniformidade da dose e medir a dose absorvida em profundidades rasas em toda extensão da superfície cutânea, tendo como consequência uma ampla variação na distribuição da dose. Os TLDs tem provado ser muito úteis para a distribuição e verificação da dose prescrita para o paciente, pois a dose pode diferir de local para local devido a geometria do corpo do paciente, sobreposições de estruturas e assimetrias do campo de radiação. A utilização de TLDs in vivo pode identificar variações da dose prescrita por apresentarem uma grande exatidão e precisão nas medidas. Nos setores de radioterapia vêm sendo empregado vários tipos de dosímetros, os mais utilizados são o Flureto de Lítio (TLD-100), onde obtém uma longa história neste tipo de aplicação. Novos materiais dosímetricos vêm ganhado grande importância na aplicação da dosímetria de feixes clínicos de elétrons, como o Sulfato de Cálcio dopado com Disprósio (TL) e o Óxido de Alumínio dopado com Carbono (OSL), este trabalho avalia o desempenho dosímetrico dos respectivos dosímetros termoluminescentes e a luminescência opticamente estimulada na aplicação da dosímetria de feixes clínicos de elétrons utilizados na irradiação total da pele. / In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin.
|
Page generated in 0.0828 seconds