• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Silva, Amanda Ribeiro Martins da 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
2

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Amanda Ribeiro Martins da Silva 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
3

Concentração de flúor no biofilme dental de indivíduos expostos a diferentes fontes de flúor de base comunitária / Dental biofilm fluoride concentration of subjects exposed to different community-based fluoride sources

Mua, Bruna January 2013 (has links)
O objetivo deste estudo foi comparar a concentração de flúor do biofilme dental de indivíduos residenteste em áreas com água fluoretada (AF) ou sal fluoretado (SF) e determinar o efeito do dentifrício fluoretado na concentração de flúor [F] do biofilme dental destes indivíduos. Dezesseis indivíduos resendentes em Montevidéu (SF) e dezesseis indivíduos residentes em Porto Alegre (AF) participaram deste estudo randomizado, cruzado e duplo-cego. Profilaxia dental e raspagem supragengivel foram realizaras antes de cada fase experimental. Durante as fases experimentais (14 dias/cada), os indivíduos escovaram os dentes, 2x/dia, com dentifrício fluoretado (DF) ou dentifrício não-fluoretado (DNF). As amostras de biofilme dental foram coletadas 8 horas após a última escovação. As análises de [F] no biofilme dental foram realizadas com um íon epecífico e as leituras foram convertidas em μgF¯/g de biofilme. Equações de estimativas generalizadas foram aplicadas para analisar a variância de medidas repetidas e as diferenças em cada desfecho. Uma maior [F] no biofilme foi observada na área com SF(2.69±0.10 IC 2.48–2.89) em comparação a área com AF (2.44±0.06 IC 2.32-2.57) quando do uso regular de DNF (p = 0.047). Entretanto, não houve diferença significativa na [F] no biofilme entre as áreas com SF (2.60±0.12 IC 2.37-2.83) e AF (2.81±0.10 CI 2.62-3.01) quando do uso de FD (p = 0.153). Adicionalmente, não foi observada diferença siginifcativa na [F] do biofilme quando DF e DNF foram usados nas áreas com SF (p = 0.294) e AF (p = 0.320). A maior [F] no biofilme observada na área com SF, sob uso regular DNF, pode não ter significância clínica, uma vez que ela desapareceu quando o DF foi usado. / The aim of this study was to compare the fluoride concentration in dental biofilm of subjects living in fluoridated- salt (FS) or water (FW) areas and to determine the effect of fluoride dentifrice on the fluoride concentration [F] in dental biofilm of these subjects. Sixteen individuals residing in Montevideo (FS) and sixteen individuals living in Porto Alegre (FW) participated in this randomized, double-blind, crossover study. Dental prophylaxis and scaling were performed prior to each experimental phase. During the experimental phases (14d/each) subjects brushed their teeth, 2x/day, with fluoridated dentifrice (FD) or non-fluoridated fluoride (NFD). Dental biofilm samples were collected 8 hours after the last toothbrushing. Analyses were performed with a fluoride ion-specific electrode and the reading was transformed into μgF¯/g biofilm. Generalized estimating equations were used to analyze the variance for repeated measures and the differences in each outcome. Higher biofilm [F] was found in FS (2.69±0.10 CI 2.48–2.89) compared to FW (2.44±0.06 CI 2.32-2.57) areas under regular use of NFD (p = 0.047). However, no significant differences were found on dental biofilm [F] between FW (2.60±0.12 CI 2.37-2.83) and FS (2.81±0.10 CI 2.62-3.01) areas under FD use (p = 0.153). Furthermore, no significant difference was observed in the biofilm [F] when FD or NFD were used in the FS (p = 0.294) and FW (p = 0.320) areas. The higher dental biofilm [F] was found in FS areas under NFD use may not have clinical significance once it disappeared when FD was used.
4

Concentração de flúor no biofilme dental de indivíduos expostos a diferentes fontes de flúor de base comunitária / Dental biofilm fluoride concentration of subjects exposed to different community-based fluoride sources

Mua, Bruna January 2013 (has links)
O objetivo deste estudo foi comparar a concentração de flúor do biofilme dental de indivíduos residenteste em áreas com água fluoretada (AF) ou sal fluoretado (SF) e determinar o efeito do dentifrício fluoretado na concentração de flúor [F] do biofilme dental destes indivíduos. Dezesseis indivíduos resendentes em Montevidéu (SF) e dezesseis indivíduos residentes em Porto Alegre (AF) participaram deste estudo randomizado, cruzado e duplo-cego. Profilaxia dental e raspagem supragengivel foram realizaras antes de cada fase experimental. Durante as fases experimentais (14 dias/cada), os indivíduos escovaram os dentes, 2x/dia, com dentifrício fluoretado (DF) ou dentifrício não-fluoretado (DNF). As amostras de biofilme dental foram coletadas 8 horas após a última escovação. As análises de [F] no biofilme dental foram realizadas com um íon epecífico e as leituras foram convertidas em μgF¯/g de biofilme. Equações de estimativas generalizadas foram aplicadas para analisar a variância de medidas repetidas e as diferenças em cada desfecho. Uma maior [F] no biofilme foi observada na área com SF(2.69±0.10 IC 2.48–2.89) em comparação a área com AF (2.44±0.06 IC 2.32-2.57) quando do uso regular de DNF (p = 0.047). Entretanto, não houve diferença significativa na [F] no biofilme entre as áreas com SF (2.60±0.12 IC 2.37-2.83) e AF (2.81±0.10 CI 2.62-3.01) quando do uso de FD (p = 0.153). Adicionalmente, não foi observada diferença siginifcativa na [F] do biofilme quando DF e DNF foram usados nas áreas com SF (p = 0.294) e AF (p = 0.320). A maior [F] no biofilme observada na área com SF, sob uso regular DNF, pode não ter significância clínica, uma vez que ela desapareceu quando o DF foi usado. / The aim of this study was to compare the fluoride concentration in dental biofilm of subjects living in fluoridated- salt (FS) or water (FW) areas and to determine the effect of fluoride dentifrice on the fluoride concentration [F] in dental biofilm of these subjects. Sixteen individuals residing in Montevideo (FS) and sixteen individuals living in Porto Alegre (FW) participated in this randomized, double-blind, crossover study. Dental prophylaxis and scaling were performed prior to each experimental phase. During the experimental phases (14d/each) subjects brushed their teeth, 2x/day, with fluoridated dentifrice (FD) or non-fluoridated fluoride (NFD). Dental biofilm samples were collected 8 hours after the last toothbrushing. Analyses were performed with a fluoride ion-specific electrode and the reading was transformed into μgF¯/g biofilm. Generalized estimating equations were used to analyze the variance for repeated measures and the differences in each outcome. Higher biofilm [F] was found in FS (2.69±0.10 CI 2.48–2.89) compared to FW (2.44±0.06 CI 2.32-2.57) areas under regular use of NFD (p = 0.047). However, no significant differences were found on dental biofilm [F] between FW (2.60±0.12 CI 2.37-2.83) and FS (2.81±0.10 CI 2.62-3.01) areas under FD use (p = 0.153). Furthermore, no significant difference was observed in the biofilm [F] when FD or NFD were used in the FS (p = 0.294) and FW (p = 0.320) areas. The higher dental biofilm [F] was found in FS areas under NFD use may not have clinical significance once it disappeared when FD was used.
5

Concentração de flúor no biofilme dental de indivíduos expostos a diferentes fontes de flúor de base comunitária / Dental biofilm fluoride concentration of subjects exposed to different community-based fluoride sources

Mua, Bruna January 2013 (has links)
O objetivo deste estudo foi comparar a concentração de flúor do biofilme dental de indivíduos residenteste em áreas com água fluoretada (AF) ou sal fluoretado (SF) e determinar o efeito do dentifrício fluoretado na concentração de flúor [F] do biofilme dental destes indivíduos. Dezesseis indivíduos resendentes em Montevidéu (SF) e dezesseis indivíduos residentes em Porto Alegre (AF) participaram deste estudo randomizado, cruzado e duplo-cego. Profilaxia dental e raspagem supragengivel foram realizaras antes de cada fase experimental. Durante as fases experimentais (14 dias/cada), os indivíduos escovaram os dentes, 2x/dia, com dentifrício fluoretado (DF) ou dentifrício não-fluoretado (DNF). As amostras de biofilme dental foram coletadas 8 horas após a última escovação. As análises de [F] no biofilme dental foram realizadas com um íon epecífico e as leituras foram convertidas em μgF¯/g de biofilme. Equações de estimativas generalizadas foram aplicadas para analisar a variância de medidas repetidas e as diferenças em cada desfecho. Uma maior [F] no biofilme foi observada na área com SF(2.69±0.10 IC 2.48–2.89) em comparação a área com AF (2.44±0.06 IC 2.32-2.57) quando do uso regular de DNF (p = 0.047). Entretanto, não houve diferença significativa na [F] no biofilme entre as áreas com SF (2.60±0.12 IC 2.37-2.83) e AF (2.81±0.10 CI 2.62-3.01) quando do uso de FD (p = 0.153). Adicionalmente, não foi observada diferença siginifcativa na [F] do biofilme quando DF e DNF foram usados nas áreas com SF (p = 0.294) e AF (p = 0.320). A maior [F] no biofilme observada na área com SF, sob uso regular DNF, pode não ter significância clínica, uma vez que ela desapareceu quando o DF foi usado. / The aim of this study was to compare the fluoride concentration in dental biofilm of subjects living in fluoridated- salt (FS) or water (FW) areas and to determine the effect of fluoride dentifrice on the fluoride concentration [F] in dental biofilm of these subjects. Sixteen individuals residing in Montevideo (FS) and sixteen individuals living in Porto Alegre (FW) participated in this randomized, double-blind, crossover study. Dental prophylaxis and scaling were performed prior to each experimental phase. During the experimental phases (14d/each) subjects brushed their teeth, 2x/day, with fluoridated dentifrice (FD) or non-fluoridated fluoride (NFD). Dental biofilm samples were collected 8 hours after the last toothbrushing. Analyses were performed with a fluoride ion-specific electrode and the reading was transformed into μgF¯/g biofilm. Generalized estimating equations were used to analyze the variance for repeated measures and the differences in each outcome. Higher biofilm [F] was found in FS (2.69±0.10 CI 2.48–2.89) compared to FW (2.44±0.06 CI 2.32-2.57) areas under regular use of NFD (p = 0.047). However, no significant differences were found on dental biofilm [F] between FW (2.60±0.12 CI 2.37-2.83) and FS (2.81±0.10 CI 2.62-3.01) areas under FD use (p = 0.153). Furthermore, no significant difference was observed in the biofilm [F] when FD or NFD were used in the FS (p = 0.294) and FW (p = 0.320) areas. The higher dental biofilm [F] was found in FS areas under NFD use may not have clinical significance once it disappeared when FD was used.
6

Avaliação rápida, direta e sem geração de resíduos de amostras da vida cotidiana por fluorescência de raios X por dispersão em energia / Fast, direct and green evaluation of daily samples by energy dispersive X-ray fluorescence

Col, José Augusto da, 1973- 01 March 2013 (has links)
Orientador: Maria Izabel Maretti Silveira Bueno / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-23T02:23:48Z (GMT). No. of bitstreams: 1 Col_JoseAugustoda_D.pdf: 9318257 bytes, checksum: 54d0d6d3a0ad6811b828d2ca100ea0cf (MD5) Previous issue date: 2013 / Resumo: A técnica de Fluorescência de Raios X (XRF) considera medidas de intensidades e energias características dos raios X emitidos por amostras submetidas à radiação X. É rápida, de baixo custo, não destrutiva e multielementar. Essas características são muito atraentes para amostras da vida cotidiana. Um exemplo apresentado no Capítulo 2 é a análise exploratória da composição elementar de materiais escolares (giz de cera, massa de modelar e tinta guache), que possuem grande apelo junto ao público infantil. Por meio do método de Parâmetros Fundamentais (PF), que corrige teoricamente o efeito interelementar, constatou-se que a maioria dos materiais não apresentava contaminação por elementos tóxicos. Porém, três marcas de guache apresentaram o elemento Br (0,0024 ± 0,0001 a 0,0137 ± 0,0002 g/100g) e uma amostra de giz de cera, Ba (0,138 ± 0,005 g/100g). No terceiro capítulo, a comparação do uso de dois equipamentos de EDXRF (portátil e bancada) ajudou na caracterização de joias e bijuterias (colares, brincos, pulseiras, anéis e piercings), por meio da determinação dos teores dos constituintes metálicos que podem oferecer risco à saúde, como Ni e Pb. Várias amostras apresentaram concentração de Ni suficiente para provocar processos alérgicos, sinalizando a necessidade de cuidados pelas agências da área de saúde. Finalmente, no quarto capítulo, a quantificação de Na e Kem sal de cozinha (refinado, marinho e light) revelou dificuldades do método de PF na quantificação de elementos leves (Z < 22). O uso de um método univariado, baseado na calibração com as áreas dos picos, é uma alternativa possível, ainda que a manipulação de arquivos consuma certo tempo. A quantificação foi realizada com boas correlações tanto para Na (r = 0,974), como para K (r = 0,992). O método multivariado usando Partial Least Square Regression (PLS), com 5 LV, mostrou-se mais rápido. As quantificações de Na forneceram erros de calibração inferiores a 16% e uma correlação de 0,995. A tendência mais preocupante encontrada nas análises foi a possível não redução indicada pela legislação para o teor de Na no sal de cozinha light, que deve ser de 50%. As aplicações apresentadas podem ser realizadas de forma rápida, multielementar e atendendo às especificações da Química Verde / Abstract: X-Ray Fluorescence (XRF) employs measurements of intensities and characteristic energies of x-rays emitted by samples submitted to X-radiation. It is fast, low-cost, non-destructive and a truly multielement analytical technique. These properties are very attractive to be applied to daily life samples. An example is the exploratory analysis of the composition of school supplies (crayons, modeling clays, and gouaches), materials largely employed by children. Through the Fundamental Parameters method (FP), that performs theoretical corrections for the interelement effect, it was observed that most of the samples did not contain toxic elements. However, three gouache brands presented Br (0.0024 ± 0.0001 to 0.0137 ± 0.0002 g/100g), and a crayon sample contained Ba (0.138 ± 0.005 g/100g). In chapter 3, the comparison of two EDXRF devices (portable and benchtop) aimed at monitoring jewelry and bijou (necklaces, earrings, rings, bracelets and piercings) through the determination of metals that may be harmful, such as Ni and Pb. Many samples presented Ni concentrations that could trigger allergic processes, clearly indicating the need for a closer monitoring by health agencies. Finally, in chapter 4, the determination of Na and K in table salts (refined, marine and light types) revealed the difficulties of the PF method when working with light elements (Z < 22). An univariate method based on peak areas calibration is an attractive alternative, even though steps of data manipulations might consume some time. Quantifications were performed with good correlations for both Na (r = 0.974), and K (r = 0.992). A Partial Least Square Regression (PLS) method with 5 LV was very fast. Na quantifications provided calibration errors lower than 16% and a correlation of 0.995. Of great concern was the observation of high Na+ levels in light cooking salts, a type consumed mostly by hypertensive patients. The presented applications may be done in a fast and multielement fashion, in accordance with the Green Chemistry specifications / Doutorado / Quimica Analitica / Doutor em Ciências

Page generated in 0.0391 seconds