• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 384
  • 336
  • 86
  • 52
  • 37
  • 21
  • 18
  • 13
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1166
  • 506
  • 236
  • 225
  • 219
  • 181
  • 177
  • 157
  • 152
  • 118
  • 109
  • 101
  • 97
  • 94
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

A molecular dynamics modeling study on the mechanical behavior of nano-twinned Cu and relevant issues

Yue, Lei 11 1900 (has links)
As a candidate for dynamic electric contacts, Nano-twinned copper has intrinsic conductivity and enhanced fretting resistance. To better understand its general mechanical behavior, we conduct molecular dynamics simulation studies to investigate responses of nano-twinned copper to stress and to one-directional and two-directional sliding processes, in comparison with single crystal and nano-grained model systems. Obtained results suggest that the twin boundary blocks dislocation movement more effectively and the degree of emitting dislocations under stress is considerably lower than that of grain boundary. The inverse H-P relation only occurring in nano-grained materials does not necessarily result from grain boundary sliding. Under sliding conditions, dislocations are easier to be generated in the single crystal system. During the two-directional sliding process, Bauschinger effect is observed in the single crystal and nano-twinned systems, while the situation is opposite for the nano-grained system. The nano-twinned Cu shows the least dislocation accumulation during two-directional sliding. / Materials Engineering
102

The ephemeral architecture of mas(k) National Centre for Carnival and Culture Trinidad & Tobago /

Lewis, Camille D. January 1900 (has links)
Thesis (M.Arch.) - Carleton University, 2006. / Includes bibliographical references (p. 130-131). Also available in electronic format on the Internet.
103

The effect of primers on the tensile bond strength between MDX 4-4210 silicone and two acrylic resins (autopolymerizing and light-polymerizing acrylic resin) /

Natdhanai Chotprasert, Theerathavaj Srithavaj, January 2006 (has links) (PDF)
Thesis (M.Sc. (Maxillofacial Prosthetics)--Mahidol University, 2006. / LICL has E-Thesis 0019 ; please contact computer services. LIRV has E-Thesis 0019 ; please contact circulation services.
104

The effect of primers on bond strength of silicones to autopolymerizing acrylic resin) /

Doan, Minh Tri, Theerathavaj Srithavaj, January 2006 (has links) (PDF)
Thesis (M.Sc. (Maxillofacial Prosthetics)--Mahidol University, 2006. / LICL has E-Thesis 0019 ; please contact computer services. LIRV has E-Thesis 0019 ; please contact circulation services.
105

Tensile properties of heat-manipulated stainless steel orthodontic wires a thesis submitted in partial fulfillment ... orthodontics /

Ponitz, Robert J. January 1955 (has links)
Thesis (M.S.)--University of Michigan, 1955.
106

Avaliacao da resistencia a tracao de um sistema adesivo self - etching em dentina irradiada com ER: YAG laser

MELLO, ANDREA M.D. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:01Z (GMT). No. of bitstreams: 1 06998.pdf: 4836505 bytes, checksum: 8807c39ebe15873ea228aaf490e0ed91 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
107

Resistência de união cerâmica - agente cimentante. Teste de micro-tração e análise por microscopia eletrônica de varredura

Faria, Ricardo Pinheiro de [UNESP] 02 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-02Bitstream added on 2014-06-13T20:41:45Z : No. of bitstreams: 1 faria_rp_dr_arafo.pdf: 1705909 bytes, checksum: 0b8648d6813e632a7474c2c61b823912 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos deste trabalho foram avaliar a influência de diferentes tempos de condicionamento ácido na resistência de união cerâmica-agente cimentante, por meio do teste de Micro-Tração, bem como análise dos modos de fratura. Foram confeccionados 5 pares de discos de cerâmica de infra-estrutura IPS Empress 2 e divididos aleatoriamente em 5 grupos. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação seqüencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: G1: sem condicionamento ácido; G2: 20 s de condicionamento com ácido fluorídrico a 10%; G3: 40 s e condicionamento com ácido fluorídrico a 10%; G4: 60 s de condicionamento com ácido fluorídrico a 10% e G5: 2 min de condicionamento com ácido fluorídrico a 10%. Os espécimes, aos pares, foram cimentados com um sistema adesivo e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 h a 37°C e, posteriormente, com auxílio de um disco de diamante perpendicular à superfície de união, palitos com 1 mmø de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS 800) e submetidos à análise de variância e teste de Tukey. As médias de resistência foram de 30,20 MPa, 36,19 MPa, 38,72 MPa, 41,43 MPa e 42,53 MPa, respectivamente aos grupos G1, G2 G3 G4 e G5. O grupo G1 apresentou menor resistência média de união do que os demais grupos. O grupo G3 teve comportamento semelhante a G2 e a G4, porém estes dois últimos foram diferentes entre si. Os grupos G4 e G5 promoveram resistências médias semelhantes. Concluímos que o aumento do tempo de condicionamento ácido aumentou os valores de resistência de... . / The purpose of this study was to investigate the effect of different times of acid conditioning on the microtensile bond strength between union-cement and ceramic, and to verify the mode of failure. Five pairs of ceramic disks (IPS Empress 2) were divided, in five groups, by randomized allocation. The bonding surfaces were finished with 600-grit silicon carbide paper. The specimens were nominated at random and submitted to the following treatments before cementation: G1 : without acid etching; G2 : 20 s of etching with 10% hydrofluoric acid; G3 : 40 s of etching with 10% hydrofluoric acid; G4 : 60 s of etching with 10% hydrofluoric acid and G5 : 2 min of etching with 10% hydrofluoric acid. All the pairs were bonded with dual cure resin bonding and dual cure resin cement, according to manufacturer's instructions. The specimens were light-cured and then stored for 48 h at 37°C. Using a diamond disk perpendicular to the bonding interface, 'sticks' with 1.0 mmø cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. It was applied analysis of variance and Tukey test at p<0.05. The means of microtensile bond strength, in MPa, were 30.20, 36.19, 38.72, 41.43 and 42.53, respectively to the groups G1, G2, G3, G4 and G5. Group G1 had the smallest microtensile bond strength and G3 had similar results when compared to G2 and G4, although G2 and G4 were different between themselves. The groups G4 and G5 showed similar means of microtensile bond strength. Conclusions: The higher the time of acid conditioning higher were the values of microtensile bond strength, and the analysis of mode of failure exhibited prevalence of adhesive failure type.
108

Análise in vitro da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras

Calixto, Abraham Lincoln [UNESP] 22 July 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-07-22Bitstream added on 2014-06-13T20:01:56Z : No. of bitstreams: 1 calixto_al_dr_arafo.pdf: 933718 bytes, checksum: 50e18e9960ea9272e8e8efc853a8ef95 (MD5) / O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... / The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below)
109

Influência da temperatura final do ciclo de aquecimento do revestimento na fluidez e na resistência à tração do Ti c.p. e da liga Ti-6AI-4V

Oliveira, Pedro Cesar Garcia de [UNESP] 28 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-28Bitstream added on 2014-06-13T19:24:13Z : No. of bitstreams: 1 oliveira_pcg_dr_arafo.pdf: 1253738 bytes, checksum: 5a53174fb0a297cd6d433f6e3972acca (MD5) / A suposição de que temperaturas mais elevadas do revestimento possam melhorar a fluidez sem alterar as propriedades mecânicas do titânio e suas ligas, determinou a realização deste trabalho. O objetivo do trabalho foi avaliar o efeito da elevação da temperatura do revestimento na fluidez e na resistência à tração do Ti c.p. e da liga Ti-6Al-4V fundidos. Para o teste de fluidez, os corpos-de-prova foram confeccionados a partir de uma tela de nylon de 20 x 20 mm de comprimento com filamentos de 0,7mm de espessura. Para o teste de tração, corpos-de-prova foram confeccionados na forma de halteres com 3,0 mm no segmento central e 42 mm de comprimento. Para ambos os ensaios os corpos-de-prova foram incluidos em revestimento Rematitan Plus e fundidos em uma máquina de fundição Discovery. Foram confecionados 30 corpos-de-prova para cada teste, sendo 5 corpos-de-prova para cada uma das três temperaturas do revestimento: 430ºC (grupo controle); 480 e 530ºC. O teste de fluidez foi realizado medindo-se a extensão total dos filamentos do padrão original utilizando-se o programa de análise de imagem (Leica Qwin, Leica ) totalizando 284mm e comparado com os padrões fundidos. O ensaio de tração foi realizado na máquina de ensaios mecânicos MTS modelo 810 à velocidade de 1,0 mm/min. Os valores de fluidez e resistência à tração foram submetidas ao teste estatístico ANOVA e teste de Tukey. Para o ensaio de fluidez houve uma diferença estatisticamente significante, tanto para os metais como para as temperaturas sendo os melhores resultados obtidos na temperatura de 530ºC, em seguida a 480ºC e 430ºC, sendo para o Ti cp apenas a temperatura de 530ºC estatisticamente significante, enquanto que para a liga a diferença estatística ocorreu para as três temperaturas. Para o teste de tração houve uma diferença estatisticamente significante apenas... / The supposition of the heating temperature of investment can to improve the casting without change the mechanical properties of titanium and their alloys, determined the realization this is study. The aim of study was to evaluate the effect of the increase mold temperature of investment on the casting and tensile strengt of CP Ti and TI-6Al-4V alloy casting. For the casting test a nylon mesh pattern measuring 20x20 mm with 0,7 mm diameter filaments. For the tensile strengt test dumbbell rods, 3.0 mm in diameter at the central segment and 42 mm in length, obtained of an aluminum matrix. The specimens of CP Ti and Ti-6Al-4V alloy were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained to each test, five samples to each an of the three temperatures of investment: 430ºC (control group); 480 and 530ºC. The castig was realized to measuring total extension of filaments the original pattern to using a image analysis program (Leica Qwin, Leica) totality 284 mm and compared with the casting patterns. The tensile strengt was measured by means of a universal testing machine, MTS model 810, at a strain of 1,0 mm/min. The values of the casting were submitted to variance analysis and Tukey test. The casting test indicated differences significant between metals and temperatures and the better results obtained on the temperature 530ºC, following 480ºC and 430ºC. For the CP Ti the temperature 530ºC presented a statistically higher, while the Ti-6aAl-4V alloy yielded statistically different all three temperatures. The tensile strengt yielded statistically different only the metals, but revealed statistically similar between the temperatures. It was concluded that increase of the temperature of investment employed the casting without change the tensile strengt, for both materials.
110

Influência da dentina bovina e do dispositivo de microtração na resistência de união de sistemas adesivos

Yamamoto, Lígia Tiaki [UNESP] 01 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-01. Added 1 bitstream(s) on 2015-09-17T15:47:33Z : No. of bitstreams: 1 000843329.pdf: 2861252 bytes, checksum: f0dbdf297658ac001c7053032294cbee (MD5) / Este trabalho teve como objetivos: simular em elementos finitos a distribuição de tensão nos dispositivos de microtração Geraldeli e Modificado durante o teste de microtração; avaliar a resistência de união entre a dentina bovina e a resina composta colada em duas direções: Esmalte-Polpa e Polpa-Esmalte, em dois dispositivos para microtração diferentes: Geraldeli e Modificado. Foi criado o modelo de elementos finitos com a geometria externa baseada em um modelo real no software CAD, e simulado as situações experimentais (geometria, carregamento e fixação) e exportado para o software de análise estrutural Ansys. Para o teste de microtração, foram confeccionados blocos de resina composta colados a dentina bovina com dois tipos de adesivos diferentes (convencional e autocondicionante), que foram testados nos dois dispositivos para microtração. Os valores de resistência de união foram tabulados e submetidos a ANOVA 3 fatores (Tipo de dispositivo X Direção da dentina X Tipo de adesivo) e Teste de Tukey (α = 0,05). As falhas de cada grupo foram classificadas em adesivas, mistas e coesivas com o auxílio de estereomicroscópio e MEV. A distribuição de tensão no dispositivo Geraldeli mostra concentração de tensão na região adesiva do palito e distribuída não-uniformemente (isolinhas oblíquas), com áreas de tração na diagonal da interface adesiva; e no dispositivo Modificado a tensão também está concentrada na região adesiva porém distribuída mais uniformemente (isolinhas paralelas), radial à área adesiva. Foram observadas diferenças significativas para a interação entre Dispositivo X Dentina X Adesivo (p = 0,001), Dispositivo X Dentina (p = 0,000), Dentina X Adesivo (p = 0,017). O adesivo e a dentina também tiveram influência nos resultados de microtração (p = 0,013 e 0,000, respectivamente). Para o dispositivo de Geraldeli, o adesivo convencional obteve melhor resistência de união que o... / This project aimed to: simulate in finite element the stress distribution in Geraldeli and Modified's microtensile device during microtensile test; evaluate the bond strength between bovine dentin and composite resin bonded in two ways: enamel-pulp and pulp-enamel tubule directions, in two different devices for microtensile test: Geraldeli and Modified. The external geometry based on a real model was done in CAD software, experimental conditions were simulated (geometry, loading and fixation) and exported to structural analysis software Ansys. For microtensile test, bovine dentin blocks were bonded to composite resin with two different types of adhesives (conventional and self-etching), which were tested on both microtensile devices. The bond strength values were tabulated and subjected to ANOVA 3-WAY and Tukey's test statistical analysis (α = 0,05). Failures in each group were classified as adhesive, cohesive and mixed in stereomicroscope and SEM. The stress distribution in Geraldeli's device shows stress concentration in the adhesive region of the stick and distributed non-uniformly (oblique contours), with tension areas in the diagonal of the adhesive interface; Modified's device show stress concentration in the adhesive region too but more evenly distributed (parallel contours, radial to the adhesive area. Significant differences for the interaction between device device X dentine X adhesive (p = 0.001), device X dentine (p = 0.000), dentin X adhesive (p = 0.017) were observed. The adhesive and dentin were also influenced the results of microtensile test (p = 0.013 and 0.000, respectively). For Geraldeli device, conventional adhesive got better bond strength than the self-etching, in Pulp-Enamel; and Pulp-Enamel way got lower bond strength for the selfetching adhesives. For modified device, there was no statistical difference among the groups

Page generated in 0.0845 seconds