Spelling suggestions: "subject:"termografia infravermelho"" "subject:"termografia vermelha""
1 |
O uso da termografia infravermelha como indicador da produção de metano em ovinos / The use of infrared thermography as an indicator of methane production in sheepBarbosa, Maíra De Carvalho Porto 27 February 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-07-11T16:54:55Z
No. of bitstreams: 1
2017_MaíradeCarvalhoPortoBarbosa.pdf: 1254299 bytes, checksum: c84caf1183b7fb43aa7c38662ea7eede (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-08-09T18:10:54Z (GMT) No. of bitstreams: 1
2017_MaíradeCarvalhoPortoBarbosa.pdf: 1254299 bytes, checksum: c84caf1183b7fb43aa7c38662ea7eede (MD5) / Made available in DSpace on 2017-08-09T18:10:54Z (GMT). No. of bitstreams: 1
2017_MaíradeCarvalhoPortoBarbosa.pdf: 1254299 bytes, checksum: c84caf1183b7fb43aa7c38662ea7eede (MD5)
Previous issue date: 2017-08-09 / As metodologias atuais para predizer a produção de metano possuem desvantagens como alto custo de aquisição e implementação, impossibilidade de conciliar avaliação do animal a pasto com resultados mais precisos, e demanda de tempo para as aferições. A termografia infravermelha é uma tecnologia alternativa para mensurar a quantidade de metano produzida e tem como vantagens um baixo custo, rapidez e eficiência na obtenção de resultados. O objetivo do estudo foi determinar se a termografia infravermelha é adequada para a predição da emissão de metano em ovelhas e qual o melhor horário após a alimentação para realizar a mensuração. Doze cordeiras da raça Santa Inês permaneceram por dois dias em câmaras respirométricas, em sistema semifechado, para determinar a produção de metano. Os animais foram divididos em dois tratamentos, de acordo com a alimentação fornecida. Durante esse período foram realizados sete registros com as câmeras termográficas, nos tempos -1h, -0,5h, 0h, 0,5h, 1h, 2h, 3h, 5h e 7h, de acordo com o horário de fornecimento do alimento, definido como 0h. A cada 24 horas foram mensuradas a produção de metano. Pelas imagens termográficas foram medidas as temperaturas máxima, mínima, média e do ponto dos flancos esquerdo e direito. Para cada horário foi calculada a diferença de temperaturas entre os flancos esquerdo e direito (esquerdo menos direito). Os dados foram submetidos à análise estatística, testando coeficiente de correlação de Pearson, regressão múltipla e análise de componentes principais. O horário da alimentação foi o que apresentou melhores resultados para a predição do consumo de matéria seca. Na hora sete foram obsevados valores estatísticos significativos, sugerindo um novo pico de produção de metano. O tempo três horas após alimentação, para ovinos, foi considerado o ideal para predizer a produção de metano com o uso de imagens de termografia infravermelha. / Current methodologies to predict methane production have disadvantages such as high acquisition and implementation costs, impossibility of reconciling animal evaluation with pasture with more accurate results, and time demand for measurements. Infrared thermography is an alternative technology for measuring the amount of methane produced and has the advantages of low cost, speed and efficiency in obtaining results. The objective of the study was to determine if the infrared thermography is adequate for predicting the emission of methane in sheep and the best time after feeding to carry out the measurement. Twelve Santa Inês lambs remained for two days in respirometric chambers, in a semi-closed system, to determine the production of methane. The animals were divided into two treatments, according to the diet provided. During this period, seven records were made with the thermographic cameras, at times -1h, -0.5h, 0h, 0.5h, 1h, 2h, 3h, 5h, and 7h, according to the feeding time, defined as 0h. Methane production was measured every 24 hours. By the thermographic images were measured the maximum, minimum, average and point temperatures at the left and right flanks. For each time, the temperature difference between the left and right flanks (left minus right) was calculated. Data were submitted to statistical analysis, testing Pearson correlation coefficient, multiple regression and principal component analysis. The feeding schedule presented the best results for the prediction of dry matter intake. At hour seven, significant statistical values were observed, suggesting a new peak of methane production. For sheep, the time three hours after feeding was considered ideal to predict the production of methane with the use of infrared thermography images.
|
2 |
Uso da termografia na análise do resfriamento de chapas soldadasRocha, Eduardo José Fernandes 31 January 2012 (has links)
Submitted by João Arthur Martins (joao.arthur@ufpe.br) on 2015-03-09T14:23:57Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertacao ER Final ABNT 2011.pdf: 6871278 bytes, checksum: 6ecbbeddc4e6910be616fbca6eefda32 (MD5) / Made available in DSpace on 2015-03-09T14:23:57Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertacao ER Final ABNT 2011.pdf: 6871278 bytes, checksum: 6ecbbeddc4e6910be616fbca6eefda32 (MD5)
Previous issue date: 2012 / Este trabalho visa estudar o resfriamento de chapas metálicas soldadas através do uso de uma câmera termográfica. Foram utilizados seis painéis retangulares de aço ASTM A36 medindo 800 x 400 x 12,7 mm. Os painéis foram soldados manualmente na posição vertical ascendente, através de soldagem pelo processo arame tubular (FCAW-G). A velocidade média de alimentação do arame foi de 5 metros por minuto. O consumível utilizado foi o arame tubular Core 71 MB DG, diâmetro 1,2 mm. Os estudos para obtenção dos campos de temperatura foram realizados em duas etapas, mediante o uso de dois sistemas de instrumentação independentes: termopares e câmera termográfica. A primeira etapa coincide com o uso de ambos os sistemas de instrumentação instalada na face oposta à soldagem, quando então cinco termopares tipo K previamente calibrados norteiam as respostas dos campos de temperatura e em comparação, chega-se ao valor estatístico da emissividade. Nesta fase a temperatura captada na chapa atinge 712°C (≈ 985 K). A segunda etapa ocorreu na mesma face da soldagem sendo as temperaturas captadas apenas através da câmera termográfica, uma vez que a emissividade já havia sido corrigida. Os resultados mostram que a chapa alcança a temperatura de 1.237ºC (≈ 1.510 K), imediatamente após a execução da soldagem. Um dado importante que necessita ser bastante estudado trata-se da emissividade em medições com câmera infravermelha. Esse ponto foi bastante discutido no trabalho e uma curva de correção da emissividade de acordo com a temperatura é sugerida. Foram apresentadas várias imagens termométricas, algumas tridimensionais, representativas do perfil de temperatura na superfície da chapa soldada. Os resultados desse trabalho confirmam o potencial do uso da termocâmera em processos de soldagem para obter dados que confirmam os valores de importantes parâmetros que garantem a qualidade da junta soldada.
|
3 |
Critérios e padrões de comportamento para avaliação de descolamentos cerâmicos com termografia de infravermelho / Criteria and patterns of behavior for the evaluation of ceramic detachment with infrared thermographyPavón de la Fé, Elier 08 December 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-05-08T20:21:14Z
No. of bitstreams: 1
2017_ElierPavóndelaFé.pdf: 8145629 bytes, checksum: 54bec80f7216a8b4e5ac343c2d2bb471 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-05-18T11:07:20Z (GMT) No. of bitstreams: 1
2017_ElierPavóndelaFé.pdf: 8145629 bytes, checksum: 54bec80f7216a8b4e5ac343c2d2bb471 (MD5) / Made available in DSpace on 2018-05-18T11:07:20Z (GMT). No. of bitstreams: 1
2017_ElierPavóndelaFé.pdf: 8145629 bytes, checksum: 54bec80f7216a8b4e5ac343c2d2bb471 (MD5)
Previous issue date: 2018-05-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A termografia de infravermelho é utilizada na avaliação de patologias em edificações, principalmente em fachadas. O descolamento no revestimento cerâmico é uma das principais patologias avaliadas com esta técnica de ensaio. No entanto, existem muitas dúvidas na aplicação e interpretação dos resultados termográficos, relacionadas com o momento de fazer a inspeção, a influência das condições de exposição da fachada e a forma de analisar os termogramas. O objetivo do trabalho foi definir critérios e padrões de comportamento a serem utilizados na avaliação de descolamentos cerâmicos com termografia de infravermelho. A pesquisa foi divida em três etapas experimentais, que incluíram estudos em placas, parede e fachadas. Nas placas, foi realizada uma análise qualitativa do comportamento térmico das principais anomalias encontradas nos termogramas e uma análise quantitativa do comportamento dos parâmetros termográficos associados aos descolamentos. Foi analisada nesta etapa a influência das principais variáveis relativas ao defeito e às condições de exposição. Na parede os parâmetros termográficos foram correlacionados com parâmetros relativos ao fluxo de calor, utilizados posteriormente na simulação térmica das fachadas. Nas fachadas foi possível validar os padrões de comportamento encontrados ao longo do estudo e propor critérios a serem utilizados na inspeção termográfica dos descolamentos. Os principais resultados foram a determinação do comportamento térmico das principais patologias e anomalias encontradas na avaliação termográfica das fachadas, a determinação dos parâmetros relativos ao fluxo de calor (gradientes e variação de temperatura da superfície) usados na escolha do momento de fazer as inspeções em campo e os critérios para avaliação dos descolamentos baseados em parâmetros termográficos (Delta-T) e parâmetros relativos ao fluxo de calor. / Infrared thermography is used in the evaluation of buildings pathologies, principally in facades. Detachment of ceramic tiles is one of the main pathologies evaluated with this technique. However, there are many doubts in the application and interpretation of the thermographic results, related to the moment of inspection, the influence of the conditions of the facade exposure and the method of thermograms analysis. The objective of the work was to define criteria and behavior parameters to be used in the evaluation of detachment of ceramic tiles with infrared thermography. The research was divided into three experimental stage, which included a study on plate, wall and facades. In the plates, a qualitative analysis of the thermal behavior of the main anomalies found in the thermograms was performed. A quantitative analysis of the behavior of the thermographic parameters associated with the detachments was performed. The influence of the main variables related to the defect and the exposure conditions, was analyzed in this stage. In the wall the thermographic parameters were correlated with parameters related to the heat flux, used later in the thermal simulation of the facades. In the facades it was possible to validate the parameters of behavior found throughout the study and to propose criteria to be used in the thermographic inspection of the detachments. The main results were the determination of the thermal behavior of the main pathologies and anomalies found in the thermographic evaluation of the façades, the determination of the parameters related to the heat flux (gradients and variation of surface temperature) used in choosing the moment of make inspection and the criteria for evaluating the detachments based on thermographic parameters (Delta-T) and parameters related to the heat flow.
|
4 |
Estudo de imagens infravermelhas do tônus vasomotor da coluna vertebral de equinos de esporte sob diferentes aspectosBello, Camila Alfaro de Oliveira 21 March 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Economia e Medicina Veterinária, Programa de Pós-Graduação em Saúde Animal, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-08-01T20:23:01Z
No. of bitstreams: 1
2017_CamilaAlfarodeOliveiraBello.pdf: 1014909 bytes, checksum: 4bfce577415ecc6c084bfeb7ed8a4215 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-08-25T16:54:45Z (GMT) No. of bitstreams: 1
2017_CamilaAlfarodeOliveiraBello.pdf: 1014909 bytes, checksum: 4bfce577415ecc6c084bfeb7ed8a4215 (MD5) / Made available in DSpace on 2017-08-25T16:54:45Z (GMT). No. of bitstreams: 1
2017_CamilaAlfarodeOliveiraBello.pdf: 1014909 bytes, checksum: 4bfce577415ecc6c084bfeb7ed8a4215 (MD5)
Previous issue date: 2017-08-25 / O estudo sobre formas terapêuticas seguras, que promovam a recuperação da saúde de forma rápida e satisfatória permitindo oferecer ao paciente melhor qualidade de vida é fundamental para o avanço da medicina direcionada aos equinos. Quando se refere aos equinos de esporte essa busca é ainda mais evidente, pois o animal em bom estado de saúde é capaz de exercer ao máximo seu potencial atlético. Sabe-se que lesões ao longo da coluna vertebral de equinos de esporte são citadas com alta frequência. Muitas dessas lesões têm sua origem no uso excessivo de determinadas regiões da coluna que pode resultar em uma injúria tecidual com liberação de íons potássio, sódio, cálcio além das substâncias algogênicas que contistuem um estado inflamatório. A grande maioria dos equinos segue em treinamento portando alguma desordem na coluna já que o próprio exercício , quando mal empregado, contribui para o seu desenvolvimento. Para esses casos a acupuntura vem se destacando como terapia capaz de aliviar a dor toracolombar devido ação direta no tônus vasomotor com consequente efeito antiinflamatório e analgésico. A termografia se mostra um exame adequado para detectar alterações vasculares superficiais. Através do estudo do mapa térmico é possível acompanhar a resposta do leito vascular local, que por sua vez está diretamente relacionando ao processo inflamatório, de acordo com os protocolos estipulados. Diante da alta casuística de lesões em coluna vertebral de equinos de esporte e da evidência crescente do potencial terapêutico da acupuntura, o objetivo desse estudo foi avaliar a ação da acupuntura no tônus vascular da coluna vertebral de equinos em atividade esportiva. Foram observados os efeitos de acordo com o tempo, número de sessões e técnicas como agulhamento a seco e em associação ao bombeamento iônico. Para tanto, uma amostra de 49 equinos de esporte entre as modalidades: salto, adestramento, polo e três tambores foi selecionada de forma intencional. Os resultados mostraram que a acupuntura exerceu influencia ativa em desordens que levaram a alteração vasomotora da coluna vertebral de equinos submetidos a treinamento atlético e competições. O tratamento reduziu de forma significante o diferencial térmico alterado obtido a partir de imagem infravermelha, sendo logo após a primeira sessão de acupuntura e ainda na segunda, quarta e décima sessões. O tratamento por acupuntura em associação ao bombeamento iônico foi tão satisfatório quanto ao agulhamento a seco, entretanto caracterizou-se por ser menos invasivo tornando mais adequado para animais sensíveis à acupuntura tradicional. A resposta observada tanto no agulhamento seco como na utilização de bombeamento iônico mostrou ser uma opção terapêutica válida para controlar processos inflamatórios presentes na coluna torácia de equinos de esporte. Dessa forma, a acupuntura promoveu melhor qualidade de vida podendo refletir diretamente no rendimento esportivo desses cavalos. / The study on safe therapeutic forms that promote the recovery of health in a fast and satisfactory way allowing offering the patient better quality of life is fundamental for the advancement of medicine directed to the equines. When referring to equine sports, this search is even more evident, since the animal in good health is able to maximize its athletic potential. It is known that injuries along the spine of sport horses are cited with high frequency. Many of these lesions have their origin in the excessive use of certain regions of the spine that can result in a tissue injury with release of K +, Na +, Ca ++ ions, besides the algogenic substances that contain an inflammatory state. The great majority of horses are still in training with some disorder in the spine since the exercise itself contributes to its development. For these cases acupuncture has been highlighted as a therapy capable of relieving thoracolumbar pain due to direct action on vasomotor tone with consequent anti-inflammatory and analgesic effect. Thermography is a suitable examination to detect superficial vascular changes. Through the study of the thermal map it is possible to monitor the response of the local vascular bed, which in turn is directly related to the inflammatory process, according to the stipulate protocols. In view of the high casuistic spine injuries in sports horses and the growing evidence of the therapeutic potential of acupuncture, the purpose of this study was to evaluate the acupuncture action on the vascular tone of the spinal column of horses in sports activity. Effects were observed according to the time, number of sessions and techniques as dry needling and in association with ionic pumping. For this, a sample of 49 equine sports among the modalities: jump, training, polo and three drums, was selected intentionally. The results showed that acupuncture exerted an active influence in disorders that led to the vasomotor alteration of the vertebral column of horses submitted to athletic training and competitions. The treatment significantly reduced the altered thermal differential obtained from the infrared image, being soon after the first session of acupuncture and still in the second, fourth and tenth sessions. The treatment by acupuncture in association with ionic pumping was as satisfactory as dry needling, however it was characterized by being less invasive making it more suitable for animals sensitive to traditional acupuncture. The clinical response observed both in dry needling and the use of ionic pumping showed to be a valid therapeutic option to control inflammatory processes present in the thoracic spine of sports horses promoting better quality of life, directly reflecting in their sports performance.
|
5 |
Efeitos da biometenergia de praticantes de meditação prânica sobre as dores crônicas de coluna vertebralSilva, César Augustus Fernandes da 24 February 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Ciências Médicas, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-04-22T14:02:58Z
No. of bitstreams: 1
2016_CesarAugustusFernandesSilva.pdf: 2401858 bytes, checksum: acf58d09eaba06d6f97f517f1584e653 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-05T20:49:17Z (GMT) No. of bitstreams: 1
2016_CesarAugustusFernandesSilva.pdf: 2401858 bytes, checksum: acf58d09eaba06d6f97f517f1584e653 (MD5) / Made available in DSpace on 2016-05-05T20:49:17Z (GMT). No. of bitstreams: 1
2016_CesarAugustusFernandesSilva.pdf: 2401858 bytes, checksum: acf58d09eaba06d6f97f517f1584e653 (MD5) / Introdução: A meditação prânica é uma modalidade de meditação constituída por técnicas de concentração e visualização que presumivelmente permitem ao praticante captar, concentrar e projetar biometenergia (BME) para atuar na manutenção e recuperação da saúde multidimensional, tanto de si mesmo (autocura), como na de outras pessoas, inclusive por meio de tratamento a distância (alterocura). Entende-se por BME o conjunto de energias não-físicas que transcendem o espaço-tempo, não é bloqueável pelas barreiras físicas e podem transmitir intenção. As propriedades da BME, inclusive seus efeitos curativos, ainda são pouco conhecidos. Objetivos: A presente investigação teve como objetivo avaliar os efeitos da BME, tanto a captada ativamente durante as práticas de meditação prânica, como a emitida a distância com intenção de cura, em indivíduos com dores crônicas de coluna, com ou sem ansiedade e depressão, bem como estabelecer algumas de suas propriedades. Metodologia: A investigação compreendeu dois estudos independentes, mas complementares. O primeiro, de série temporal, constou da observação de 49 indivíduos que praticaram meditação prânica por cinco semanas e aprenderam a manipular ativamente BME em seu benefício. O segundo estudo, com delineamento do tipo cross-over, duplo-cego e aleatorizado, foi realizado com 26 indivíduos que receberam, durante três semanas, 12 sessões de cerca de 17 minutos de tratamento a distância com projeção de BME dotada de intenção de cura, realizado por praticante experiente de meditação prânica. Os participantes dos dois estudos apresentavam dores crônicas de coluna, com ou sem manifestações de ansiedade e/ou depressão. Para avaliar a intensidade da dor foram utilizados o questionário de dor de McGill (estudos 1 e 2) e a escala de dor de faces (estudo 2). A ansiedade e a depressão foram avaliadas pelos respectivos inventários de Beck (estudos 1 e 2). A qualidade de vida foi avaliada no estudo 1 mediante o uso do questionário de qualidade de vida desenvolvido pela Organização Mundial da Saúde (WHOQOL–BREF). O campo biometenergético foi mensurado antes e após cada sessão de meditação prânica (estudo 1), ou de tratamento a distância (estudo 2), e foram captadas imagens termográficas das costas dos participantes durante os tratamentos com BME e os tratamentos simulados, utilizando-se câmara sensível à radiação infravermelha (estudo 2). Resultados: No primeiro estudo, após cinco semanas de práticas de meditação prânica, os participantes apresentaram redução significativa das dores crônicas de coluna (p<0,0001) e das manifestações de ansiedade (p=0,006) e depressão (p=0,0007), e melhora da qualidade de vida (p<0,0001). Em paralelo à melhora das condições clínicas, observou-se aumento do campo biometenergético dos participantes (p<0,0001) nos sujeitos que praticaram a meditação com assiduidade. Os resultados do segundo estudo mostraram que três semanas de tratamento a distância com BME foram capazes de reduzir as dores crônicas (p=0,02) e as manifestações de ansiedade ajustada pela depressão (p<0,001), bem como das manifestações de depressão ajustada pela ansiedade (p=0,003). Após cada sessão de tratamento com BME, os participantes apresentaram melhora da intensidade da dor, avaliada pela escala de dor de faces (p=0,01), o que não ocorreu com aqueles que receberam tratamento simulado. Também foi possível observar significativa ampliação do campo biometenergético (p=0,001) e aumento da temperatura cutânea ao longo da coluna vertebral (p<0,001) nos sujeitos tratados com BME, mas não nos que receberam tratamento simulado. Conclusões: A presente investigação mostrou que tanto a captação ativa de BME por praticantes recentes de meditação prânica, como a emissão de BME com intenção de cura por praticante experiente de meditação prânica, tiveram efeitos benéficos em indivíduos com dor crônica, com ou sem manifestações de ansiedade e/ou depressão. Nossos resultados indicam que o tratamento a distância com BME emitida com intenção de cura, mas não o tratamento simulado, foi capaz de aumentar a temperatura corpórea ao longo da coluna vertebral e ampliar o campo biometenergético dos sujeitos do estudo. Estes achados podem ser considerados como potenciais marcadores da eficiência de tratamentos biometenergéticos. _______________________________________________________________________________________________ ABSTRACT / Introduction: Pranic meditation is a modality of meditation whose techniques allow the practitioner purportedly to capture, concentrate, and project biometenergy (BME), capable to act for the maintenance and recovery of multidimensional health, both of ourselves (self-healing), and of other people (alter-healing), including by means of treatments at a distance. It is postulated that BME is an array of non-physical energies that transcend space-time, are not blocked by physical barriers and can convey intention. The properties of BME, including its healing effects, are poorly understood. Objectives: The present investigation aimed at evaluating the effects of BME, both that actively captured by pranic meditation practitioners, as well as that projected at a distance by them, on chronic back pain, anxiety, and depression, as well as to establish some of its properties. Methodology: The investigation comprised two independent but complementary studies. The first one, a temporal series study, consisted of the observation of 49 recent pranic meditation practitioners suffering of chronic back pain, who learned how to actively manipulate BME to benefit them, during a period of 5-week of meditation practices. The second study was a randomized, cross-over, double-blind evaluation of 26 individuals, who were treated at a distance with 12 sessions of about 17 minutes each, provided by a experienced practitioner of pranic meditation, who projected to them BME with healing intention. The participants of both studies presented chronic back pain with or without anxiety and/or depression. To evaluate pain intensity both the McGill questionnaire (studies 1 and 2) and the faces pain scale (study 2) were used, while anxiety and depression were assessed by the Beck Anxiety Inventory and the Beck Depression Inventory, respectively (studies 1 and 2). The quality of life of the subjects of study 1 was evaluated by means of the questionnaire adopted by the World Health Organization (WHOQOL-BREF). To evaluate the properties of BME, the biometenergetic field was measured before and after each session of pranic meditation (study 1), or of treatment at a distance (study 2), and thermographic images from the back of patients were captured by an infrared-sensitive camera during BME or sham treatments (study 2). Results: In the first study, the participants presented a significant improvement of their manifestations of chronic pain (p<0.0001), anxiety (p=0.006), and depression (p=0.0007), as well as of their quality of life (p<0.0001), after 5 weeks of pranic meditation practice. In parallel with these improvements, a significant increment of the biometenergetic field (p<0.0001) of the practitioners was observed. The results of the second study showed that three weeks of BME treatment at a distance with healing intention were able to significantly reduce chronic back pain (p=0.02), and the manifestations of anxiety adjusted by depression (p<0.001), and depression adjusted by anxiety (p=0.003). After each session of BME treatment, but not of sham treatment, the subjects presented a significant decrease of pain intensity (p=0.01), as assessed by the faces pain scale. It was also observed a significant increase of the biometenergetic field (p=0.001), and of the skin temperature alongside the vertebral column (p<0.001) in the subjects treated with BME, but not in those submitted to sham treatment. Conclusions: The present investigation showed that both the active manipulation of BME by recent practitioners of pranic meditation, and the passive reception of BME with healing intention provided by an experienced pranic meditation practitioner, had beneficial effects on individuals with chronic back pain with or without associated anxiety and/or depression. Our results indicate that the projection of BME with healing intention, but not the sham treatment, increased the skin temperature alongside the vertebral column and expanded the biometenergetic field of the subjects who were submitted to its action. These findings allow us to consider these procedures as possible markers to evaluate the effect of biometenergetic treatments, something that does not exist nowadays.
|
6 |
Inspeção termográfica de danos por impacto em laminados compósitos sólidos de matriz polimérica reforçada com fibras de carbono. / Thermographic inspection of impact damage in solid fiber-reinforced polymer matrix composite laminates.Almeida, Euripedes Guilherme Raphael de 30 April 2010 (has links)
Laminados compósitos com matrizes poliméricas, respectivamente termorrígida e termoplástica, reforçadas com fibras contínuas de carbono foram submetidos a impacto único transversal com diferentes níveis de energia. Os danos imprimidos aos materiais estruturais foram avaliados por termografia ativa infravermelha na modalidade transmissão. Em geral, os termogramas do laminado termoplástico apresentaram indicações mais claras e bem definidas dos danos causados por impacto, se comparados aos do compósito termorrígido. O aquecimento convectivo das amostras por fluxo controlado de ar se mostrou mais eficaz que o realizado por irradiação, empregando-se lâmpadas incadecentes. Observou-se também que tempos mais longos de aquecimento favoreceram a visualização dos danos. O posicionamento da face impactada do espécime, relativamente à câmera infravermelha e à fonte de calor, não afetou a qualidade dos termogramas no caso do laminado termorrígido, enquanto que influenciou significativamente os termogramas do compósito termoplástico. Os resultados permitiram concluir que a termografia infravermelha é um método de ensaio não-destrutivo simples, robusto e confiável para a detecção de danos por impacto inferior à 5 Joules em laminados compósitos poliméricos reforçados com fibras de carbono. / Continuous carbon fiber-reinforced thermosetting and thermoplastic composite laminates were exposed to single transversal impact with different energy levels. The damages marked to the structural materials were evaluated by active infrared thermography in transmission mode. In general, the thermoplastic laminate thermograms showed more clear and delineated damage indications when compared to the ones from thermosetting composite. The convective heating of the samples by controlled hot air flow was more efficient than via irradiation using lamp. It was also observed that longer heating times improved the damage visualization. The positioning of the specimen´s impacted face regarding the infrared camera and the heating source did not affect the thermo-imaging of thermosetting specimens, whereas it substantially influenced the thermograms of thermoplastic laminates. The results allow concluding that infrared thermography is a simple, robust and trustworthy methodology for detecting impact damages as light as 5 Joules in carbon fiber composite laminates.
|
7 |
Correlação numérico- experimental entre o método dos elementos de contorno e termografia aplicados a placas de argamassaGuimarães, Denise Cardoso 02 June 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-07-14T14:44:35Z
No. of bitstreams: 1
2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-11T22:50:20Z (GMT) No. of bitstreams: 1
2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5) / Made available in DSpace on 2017-09-11T22:50:20Z (GMT). No. of bitstreams: 1
2017_DeniseCardosoGuimaraes.pdf: 5529443 bytes, checksum: e61b9ec68c6fedba006aef68e12b3e02 (MD5)
Previous issue date: 2017-09-11 / As fachadas são elementos que desempenham um papel muito importante nas edificações, pois são responsáveis por garantir e controlar com eficácia as trocas de calor, ar e luminosidade existentes entre o interior e exterior da edificação, além da qualidade visual (estética da edificação). Sabe-se que, ao longo do tempo, os revestimentos das fachadas estão expostos as intempéries, as quais podem gerar danos ou anomalias em sua estrutura, como descolamento de cerâmicas.Por outro lado, a busca por resultados com menor custo, o uso de processos não-destrutivos, bem como o uso de procedimentos e ferramentas numéricas que permitam análises rápidas, como o Método dos Elementos de Contorno (MEC), têm se tornado importantes tópicos neste campo de pesquisa. Neste contexto, o presente trabalho tem como objetivo estudar a influência da profundidade das fissuras presentes nos revestimentos de fachada, através da modelagem do fluxo de calor de uma placa de argamassa contendo duas fissuras, submetida a um ciclo de aquecimento direto. Para tanto se realizou uma modelagem numérica, onde a interface gráfica chamada BEMLAB2D foi responsável pela geração da malha (frontal e lateral) em elementos de funcionalidade constante, e um programa de análises, escrito em MATLAB, para problemas de Potencial via MEC com Sub-região, responsável pelos cálculos de temperatura e fluxo em pontos do contorno e interior. Observando os resultados obtidos através da modelação numérica e comparando com os resultados experimentais, constata-se que é possível detectar diferenças no comportamento do fluxo de calor devido à profundidade das fissuras, o que demonstra também a acurácia e eficiência da análise junto aos dados experimentais. / The facades are elements that perform an important role in the buildings, either for ensuring and effectively control the heat, air and light changes between the interior and exterior of the building, as well as the visual quality (building aesthetics). Over time, the outer coating is exposed to the weather, which can cause damage or structural anomalies as detachment of ceramics, for example. On the other hand, the search for results at lower cost, the use of non-destructive processes, and the use of procedures and numerical tools which enable quick and efficient analyzes, such as the Boundary Element Method (BEM), have become an important topics in scientific research. In this context, the present work aims to study the influence of cracks depth on facade coatings by modeling the heat flow of a mortar plate containing two cracks, subjected to a direct heating cycle. Here, the methodology consists of a numerical modeling, based on data from thermography extracted from experimental tests on cracked mortar plates, where two programs has been used: the BEMLAB2D GUI for modeling and boundary element mesh generation, as well as an analysis program, written in MATLAB, for Potential problems via BEM with Sub-region, for calculations of temperature and flow at boundary and internal points. Observing the results of numerical modeling and comparing the experimental results, it is found that it is possible to detect differences in the heat flow behavior due to the cracks depth, which also demonstrates the accuracy and efficiency of the methodology adopted between numerical and experimental analysis.
|
8 |
Modelagem da distribuição de temperatura numa junta soldada do aço API 5L X80 com validação do modelo por imagens termográficasROCHA, Eduardo José Fernandes 22 December 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2018-03-27T16:45:38Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Tese Eduardo Rocha_ Março 2017_Final.pdf: 6940724 bytes, checksum: d7e77c81e57f723257434d9f0195799a (MD5) / Made available in DSpace on 2018-03-27T16:45:38Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Tese Eduardo Rocha_ Março 2017_Final.pdf: 6940724 bytes, checksum: d7e77c81e57f723257434d9f0195799a (MD5)
Previous issue date: 2016-12-22 / CAPES / Este trabalho visa realizar estudos de distribuição de temperatura num processo de soldagem com enchimento ao arco elétrico mediante aplicação de uma modelagem matemática e validados com o auxílio de equipamentos de medição de calor que operam no intervalo do espectro da radiação infravermelha. A metodologia numérica baseou-se no método de elementos finitos, suportados pelo software Abaqus 6.12 que permitiu realizar uma análise em três dimensões do calor envolvido neste enchimento. A modelagem da fonte de calor em movimento foi empreendida com base na dupla elipsoide de Goldak e consequente distribuição do volume de energia, onde incluem-se as propriedades termofísicas do material e respectivas condições de contorno inerentes ao sistema. O campo experimental serviu de base para alimentar os dados computacionais e neste, foram utilizados painéis retangulares de aço ASTM A36 medindo 300 mm x 200 mm x 4,76 mm com soldagem por enchimento, sem entalhe no cordão de solda, bem como o uso de painéis retangulares do aço API 5L X80 medindo 150 mm x 80 mm x 7,5 mm com profundidade de chanfro de 4mm, tendo sido realizados em ambos modelos, soldagem com sistema semi-automatizado na posição horizontal 2G, por intermédio do processo de soldagem GMAW (Gas Metal Arc Welding), especificamente MAG (Metal Active Gas). Os estudos para obtenção dos campos de temperatura foram realizados sob diferentes condições de aporte térmico, fazendo-se uso de dois sistemas independentes de termografia infravermelha aplicados na forma passiva: pirômetro e câmera termográfica. A primeira etapa coincide com o uso de ambos os sistemas de instrumentação quando estes, previamente calibrados, norteiam as respostas dos campos de temperatura e em comparação, pode-se validar a câmera termográfica como um instrumento confiável. Nesta fase, a temperatura captada na chapa atinge 670°C (≈ 943 K). A segunda etapa ocorreu em disposição semelhante, sendo captada temperaturas apenas através da câmera termográfica. Os resultados mostram que a chapa alcança a temperatura de 1.045ºC (≈ 1.318 K), sendo possível captar a curva completa do ciclo térmico de soldagem na face oposta ao cordão de solda. Propriedades térmicas dependentes no tempo, bem como, efeitos de mudança de fase foram considerados. Em substituição ao uso de termopares fora assumido aplicar-se a técnica da termografia infravermelha que, comparativamente à modelagem numérica, foram obtidos excelentes graus de coerência na quantificação dos demasiados campos térmicos vigentes na soldagem. / This work aims to conduct temperature distribution studies in a welding process that involves electric arc filling with the use of a mathematical model, where validation was performed with the aid of a heat measurement equipment operating in the infrared spectrum range. The numerical methodology was based on the finite element method, supported by Abaqus 6.12 software, which enabled a three-dimensional analysis of the heat involved in the filling. The modeling of the heat source in motion was based on Goldak's double ellipsoid and the consequent energy volume distribution, including the thermophysical properties of the material and the respective boundary conditions inherent to the system. The experimental field served as a basis for providing the computational data, in which rectangular panels made of ASTM A36 steel measuring 300 mm x 200 mm x 4.76 mm were used with welding by filling, without notch in the weld bead, as well as the use of rectangular panels made of API 5L X80 steel measuring 150 mm x 80 mm x 7.5 mm with a chamfer depth of 4 mm, where semi-automated welding system in the 2G horizontal position have been realized in both models through the GMAW welding process (Gas Metal Arc Welding), specifically MAG (Metal Active Gas). The studies required to obtain the temperature fields were carried out under different thermal input conditions, applying passively two independent infrared thermography systems: pyrometer and thermographic camera. The first step coincides with the use of both instrumentation systems which when previously calibrated, direct the temperature field responses and in comparison, it becomes possible to validate the thermographic camera as a reliable instrument. At this stage, the temperature captured on the plate reaches 670 ° C (≈ 943 K). The second stage occurred in a similar arrangement, with temperatures being captured only through the thermographic camera. The results show that the plate reaches a temperature of 1,045ºC (≈ 1,318 K), making it possible to capture the complete curve of the thermal welding cycle on the opposite side of the weld bead. Time-dependent thermal properties, as well as phase change effects were considered. In substitution to the use of thermocouples, the infrared thermography technique was applied, which, when compared to numerical modeling, demonstrated excellent coherence degrees with respect to other thermal fields in welding.
|
9 |
Inspeção termográfica de danos por impacto em laminados compósitos sólidos de matriz polimérica reforçada com fibras de carbono. / Thermographic inspection of impact damage in solid fiber-reinforced polymer matrix composite laminates.Euripedes Guilherme Raphael de Almeida 30 April 2010 (has links)
Laminados compósitos com matrizes poliméricas, respectivamente termorrígida e termoplástica, reforçadas com fibras contínuas de carbono foram submetidos a impacto único transversal com diferentes níveis de energia. Os danos imprimidos aos materiais estruturais foram avaliados por termografia ativa infravermelha na modalidade transmissão. Em geral, os termogramas do laminado termoplástico apresentaram indicações mais claras e bem definidas dos danos causados por impacto, se comparados aos do compósito termorrígido. O aquecimento convectivo das amostras por fluxo controlado de ar se mostrou mais eficaz que o realizado por irradiação, empregando-se lâmpadas incadecentes. Observou-se também que tempos mais longos de aquecimento favoreceram a visualização dos danos. O posicionamento da face impactada do espécime, relativamente à câmera infravermelha e à fonte de calor, não afetou a qualidade dos termogramas no caso do laminado termorrígido, enquanto que influenciou significativamente os termogramas do compósito termoplástico. Os resultados permitiram concluir que a termografia infravermelha é um método de ensaio não-destrutivo simples, robusto e confiável para a detecção de danos por impacto inferior à 5 Joules em laminados compósitos poliméricos reforçados com fibras de carbono. / Continuous carbon fiber-reinforced thermosetting and thermoplastic composite laminates were exposed to single transversal impact with different energy levels. The damages marked to the structural materials were evaluated by active infrared thermography in transmission mode. In general, the thermoplastic laminate thermograms showed more clear and delineated damage indications when compared to the ones from thermosetting composite. The convective heating of the samples by controlled hot air flow was more efficient than via irradiation using lamp. It was also observed that longer heating times improved the damage visualization. The positioning of the specimen´s impacted face regarding the infrared camera and the heating source did not affect the thermo-imaging of thermosetting specimens, whereas it substantially influenced the thermograms of thermoplastic laminates. The results allow concluding that infrared thermography is a simple, robust and trustworthy methodology for detecting impact damages as light as 5 Joules in carbon fiber composite laminates.
|
10 |
Percepção de suínos em relação ao ambiente térmico promovido por diferentes sistemas de resfriamento / Perception of pigs in relation to the thermal environment promoted by different cooling systemsOliveira, Débora Caroline Gonçalves de 16 July 2015 (has links)
O controle ambiental nas instalações pecuárias é um fator importante a ser levado em consideração para promover o bem-estar e otimizar a produção animal. Como o clima brasileiro é predominantemente tropical, sistemas de resfriamento são essenciais em instalações pecuárias em todo o país. Diferentes sistemas de resfriamento estão disponíveis no mercado brasileiro e, apesar de possuírem o mesmo objetivo, de atenuar a temperatura dentro do galpão, podem ser percebidos pelos animais de modos diferentes. O objetivo principal deste trabalho foi avaliar a percepção de suínos através de sua preferência em relação a diferentes sistemas de resfriamento do ambiente em uma câmara de preferência ambiental. Esta avaliação foi feita por meio do teste de preferência, que consiste em fornecer alternativas entre diferentes situações ou recursos, para que os animais transmitam suas respostas. Para tanto, foi utilizada uma câmara de preferência ambiental composta por quatro compartimentos interligados entre si por uma área neutra. Cada compartimento teve seu ambiente controlado independentemente, podendo assim fornecer, quatro diferentes tipos de sistemas de resfriamento: nebulização associada à ventilação forçada, ventilação forçada, aspersão e aspersão associada a ventilação forçada. Nesse estudo de preferência, dois grupos principais de suínos foram utilizados: os suínos-teste e os suínos-companhia. Os suínos-teste foram os animais com livre acesso aos distintos compartimentos da câmara e os suínos-companhia, por sua vez, ficaram confinados em seus respectivos sistemas. Para caracterização do ambiente no interior e no exterior da câmara, foram utilizados data-loggers para coleta das variáveis: temperatura ambiental, umidade relativa, temperatura de globo negro e ponto de orvalho; para determinação dos índices de conforto térmico: índice de temperatura de globo e umidade e entalpia. Também foi coletada a velocidade do ar com anemômetro digital. Foram verificadas medidas fisiológicas: frequência respiratória e temperatura de superfície corporal na região da nuca no horário das 14 horas. Para analisar o desempenho dos animais foi avaliado ganho de peso diário e conversão alimentar, além das medidas in vivo de espessura de toucinho, rendimento de carne magra e profundidade da área do lombo. Para avaliação do teste de preferência foram considerados dias que caracterizassem condições climáticas em que os sistemas de resfriamento estivessem em operação. Para isto vídeos coletaram e registraram as imagens e estas foram analisadas automaticamente e interpretadas como preferência por (ou rejeição de) certos ambientes através de frequência e tempo do suíno-teste em cada um dos ambientes. A câmara conseguiu atender os valores recomendados para o índice de temperatura de globo e umidade, temperatura ambiental e umidade relativa ao longo dos períodos do dia, os valores obtidos para entalpia estiveram acima do recomendado na literatura. Porém o desempenho da câmara foi satisfatório, uma vez que as medidas fisiológicas de frequência respiratória e temperatura superficial, e as variáveis de desempenho indicaram que os animais estavam em conforto térmico e obtiveram medidas de espessura de toucinho, rendimento de carne magra e profundidade da área do lombo característicos para a categoria. Em relação à preferência dos suínos-teste, observou-se a maior frequência de permanência nos sistemas de aspersão (40%) e aspersão associada à ventilação forçada (34,7%). Assim os resultados obtidos validaram o uso da câmara de preferência ambiental para experimentação com suínos a fim de verificar sua preferência em relação a diferentes ambientes térmicos com diferentes sistemas de resfriamento. / Environmental control in livestock buildings is an important factor to be taken into account to promote the welfare and optimize the animal production. As the Brazilian climate is predominantly tropical, cooling systems are essential in animal facilities across the country. Different cooling systems are available in the Brazilian market and, despite having the same goal, to mitigate the temperature inside the shed, they can be perceived by the animals in different ways. The aim of this study was to evaluate the perception of pigs through their preference in relation to the different environment of the cooling systems in an environmental preference chamber. This assessment was made by the preference test, which is to provide alternatives between different situations or resources, so that the animals transmit their responses. An environmental preference chamber was used, and consisted of four compartments connected to each other by a neutral area. Each compartment has its environmental conditions controlled independently, and may thus provide four different types of cooling system: nebulizer associated to forced ventilation, forced ventilation, sprinkler and sprinkler associated to forced ventilation. In this preference study, two main groups of pigs were used: the test-pigs and companion-pigs. The test-pigs were the animals with free access to the chamber and companion-pigs, in turn, were confined in their respective systems. To characterize the environment inside and outside the chamber, data-loggers were used to collect the variables: ambient temperature, relative humidity, black globe temperature and dew point; to determine the levels of index thermal comfort: globe temperature and humidity index and enthalpy. The air speed with digital anemometer also was collected. Physiological measures were also registered: respiratory rate and body surface temperature in the neck region in the schedule at 2pm. Daily gain and feed conversion were evaluated to analyze the performance of the animals in addition to the measures in vivo backfat thickness, lean yield and depth of loin area. The preference test considered days that characterize climatic conditions in which the cooling systems were in operation. The video images were collected and recorded and they were automatically analyzed and interpreted as a preference (or rejection) of certain environments through the frequency and time that test-pig in each environment. The environmental preference chamber conditions attended the recommended values for globe temperature and humidity index, ambient temperature and relative humidity over the periods of the day, and the values obtained for enthalpy were slightly above the recommended literature. The chamber performance was satisfactory since the physiological measures respiratory rate and body surface temperature and the performance variables indicated that the animals were in thermal comfort and obtained backfat thickness, lean yield and depth of loin area measures, characteristic for the category. Regarding the preference of the test-pigs, the highest frequency was observed in sprinkler (40%) and sprinkler associated to forced ventilation (34,7%) systems. Thus the results validated the use of the environmental preference chamber for experimentation with pigs in order to verify their perception to different thermal environments with different cooling systems.
|
Page generated in 0.0755 seconds