• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 6
  • 6
  • 6
  • 6
  • 5
  • 1
  • 1
  • 1
  • Tagged with
  • 98
  • 98
  • 59
  • 57
  • 19
  • 17
  • 16
  • 15
  • 15
  • 14
  • 12
  • 12
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito de cargas compressivas oblíquas e da simulação de ciclos mastigatório sobre pilares para implantes cone morse / Effects of oblique compressive load and simulated chewing cycles on internal tapered implant-abutment connections

Izabela Cristina Mauricio Moris 15 December 2011 (has links)
A literatura relata que a união osso/implante é extremamente confiável, porém limitações clínicas em relação à prótese ainda ocorrem. Recentemente foi proposto um pilar para implantes cone morse cujo desenho permite a escolha entre coroas cimentadas ou parafusadas, adicionalmente, este pilar também é apresentado em dois tamanhos, o convencional (ø 4,8 mm) e reduzido (ø 3,8 mm). O objetivo deste estudo foi avaliar a resistência à deformação dos pilares protéticos, a resistência de cimentação das coroas e os efeitos da simulação de ciclos mastigatórios sobre: adaptação marginal, perda de torque nos parafusos das coroas e perda de torque dos dois diferentes pilares. Para avaliar a resistência à deformação, 20 implantes/pilares com diâmetro de 4.8 e 3.8 foram submetidos à carga compressiva oblíqua. Para avaliar as outras situações, 40 implantes/pilares foram divididos nos seguintes grupos (N=10): G4.8P- pilar de 4.8 e coroas parafusadas; G4.8C-pilar de 4.8 e coroas cimentadas; G3.8P- pilar de 3.8 e coroas parafusadas; G3.8C- pilar de 3.8 e coroas cimentadas. Todas as coroas foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios e as coroas cimentadas foram submetidas ao teste de resistência à tração previamente ao ensaio. Os conjuntos foram submetidos a 300.000 ciclos de simulação de movimentos mastigatórios. A perda de torque das coroas parafusadas e de todos os pilares foi analisada antes a após o ensaio. Não houve diferenças significantes para a resistência à deformação entre os pilares; para a resistência de cimentação houve diferenças significantes entre os dois pilares (p≤0,05). Para a adaptação marginal houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre os grupos G3.8P (p=0,037) e G3.8C (p≤0,05); para a comparação da adaptação das coroas entre os pilares houve diferenças antes da simulação dos ciclos mastigatórios quando comparado os grupos 3.8C com 3.8P e antes e após da simulação quando comparado os grupos 4.8C com 4.8P, para as demais comparações não houve diferença. Quanto à perda de torque nos parafusos das coroas houve diferenças significantes antes e após a simulação dos ciclos mastigatórios para ambos os pilares, quanto às comparações entre os diferentes grupos antes e após a simulação de ciclos mastigatórios houve diferença apenas após (p=0,008) a simulação. Quanto à perda de torque para os pilares houve diferenças significantes apenas para o grupo 3.8C (p≤0,05) antes e após a simulação dos ciclos mastigatórios. Considerando as limitações deste estudo, conclui-se que em relação à resistência à deformação os pilares apresentaram valores próximos; quanto a retenção das coroas, cimentadas e parafusadas, os pilares de 4.8 foram estatisticamente superiores aos pilares de 3.8; a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das coroas e em relação a perda de torque dos pilares não foram encontradas diferenças estatísticas. / Reports in the literature have stated that the bone/implant interface is extremely reliable. However, clinical limitations in relation to the prosthesis still occur. A Morse taper implant-abutment design that allows choosing between cemented or screwed crowns has been recently proposed. The abutment is presented in two different diameter sizes (conventional (ø 4.8 mm) and narrow (ø 3.8 mm). The aim of this study was to evaluate the resistance to deformation of the implant/abutment interface, the tensile strength of the cemented crowns and the effects of simulated chewing cycles on: marginal fit, crown-screw torque loss and torque loss of the two different abutments. To evaluate the resistance to deformation, 20 abutments with diameter of 4.8 and 3.8 were subjected to compressive oblique load. To evaluate the other situations, 40 implants/abutments were divided into the following groups (N = 10): G4.8P-abutment 4.8 with screwed crowns; G4.8C-abutment 4.8 with cemented crowns; G3.8P abutment 3.8 with screwed crows; G3.8C-abutment 3.8 with cemented crowns. All crowns were evaluated for marginal fit before and after simulation of the chewing cycles. The cemented crowns were subjected to tensile strength test before the simulated chewing cycles. The specimens were subjected to 300,000 cycles that simulated the chewing movements. The torque loss of the screwed crowns and all abutments were analyzed before and after the cycling tests. No significant differences were found for the deformation resistance between the abutments. No significant differences were found in the tensile strength of the cemented crowns between the two abutments (p≤0.05). The marginal fit of the crowns found no significant differences before and after the simulation of the chewing cycles between groups G3.8P (p = 0.037) and G3.8C (p≤0.05). No differences were found in crown misfit between the abutments before simulating the chewing cycles when compared between groups 3.8C 3.8P. No differences were found between groups 4.8C and 4.8P before and after the chewing simulation. Torque loss of the screwed crowns was not significantly different before and after the simulation of the chewing cycles for both abutments. Comparisons between the different groups before and after simulation found significant differences after the simulation of the chewing cycles (p = 0.008). Group 3.8C was the only group that presented significant differences (p≤0.05) before and after the simulation cycles. Within the limitations of this study, it can be concluded that the resistance to deformation between both abutments was similar. Retention of cemented and screwed crowns was statistically higher for the 4.8 abutments when compared to the 3.8 abutments. The simulation of chewing cycles significantly influenced the marginal fit of the crowns. No differences statistically significant in torque loss were found between the two abutments.
22

Avaliação física, química e biológica em diferentes superfícies de uma liga de titânio-molibdênio /

Florian, Fernanda. January 2018 (has links)
Orientador: Joni Augusto Cirelli / Resumo: Com o alto índice de sucesso dos implantes, o desenvolvimento de novas ligas e tratamentos de superfície tem sido o grande enfoque das pesquisas da área. O objetivo desse trabalho foi caracterizar a liga binária composta de Ti-15Mo que recebeu um tratamento químico a base de ácido fosfórico, seguido ou não por tratamento de hidróxido de sódio e também tratamento de laser com deposição de apatita para em seguida avaliar a resposta in vitro de osteoblastos de ratos. A metodologia aplicada avaliou a liga através dos testes de microscopia eletrônica de varredura associada à espectroscopia por energia dispersiva de raios X, medidas de rugosidade e área efetiva com microscópio confocal a laser e ângulo de contato. Os ensaios biológicos verificaram a resposta dos osteoblastos a essas superfícies observando a morfologia, adesão e proliferação celular, além da quantificação de nódulos de mineralização, níveis de atividade de fosfatase alcalina e expressão gênica de marcadores da osteogênese. Os resultados demonstram que os tratamentos de superfície realizados atingiram os objetivos de modificar as características físico-químicas do Ti-cp e Ti-15Mo, de forma que os eventos intermediários observados na RBMSC sugerem favorecer a osseointegração. As células osteoblásticas se comportaram de forma semelhante entre as superfícies tratadas, sem diferenças significativas, sugerindo que a liga Ti-15Mo é uma alternativa para o uso na Implantodontia pelas vantagens de sua propriedade mecânica. Es... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With the high success rate of implants, the development of new alloys and surface treatments has been the major focus of research in the area. The aim of this study was to characterize the binary composite alloy of Ti-15Mo that received a chemical treatment based on phosphoric acid, followed or not by sodium hydroxide and also laser treatment with deposition of apatite to next evaluate the in vitro response of rat osteoblasts. The applied methodology evaluated the alloy through scanning electron microscopy associated to X-ray dispersive energy spectroscopy, roughness measurements and effective area with laser confocal microscope and contact angle. The biological tests verified the response of osteoblasts to these surfaces by observing cell morphology, adhesion and proliferation, as well as the quantification of mineralization nodules, levels of alkaline phosphatase activity and gene expression of osteogenesis markers. The results demonstrate that the surface treatments performed reached the goals of modifying the physicochemical characteristics of the Ti-cp and Ti-15Mo alloy, so that the intermediate events observed in the RBMSC suggest that they favor osseointegration. The osteoblastic cells behaved similarly in both alloys and surface treatments, without significant differences, suggesting that the Ti-15Mo alloy is an alternative for the use in the Implantology for the advantages of mecanical property. These results are expected to determine benefits for possible biological... (Complete abstract click electronic access below) / Doutor
23

Physicochemical and biological properties of Biodentine associated with radiopacifiers /

Ochoa Rodríguez, Victor Manuel January 2018 (has links)
Orientador: Gisele Faria / Resumo: BiodentineTM (BD) apresenta bioatividade, biocompatibilidade e propriedades físico-químicas adequadas; no entanto, não possui radiopacidade adequada. Os objetivos foram avaliar (1) a radiopacidade de BD e BD associado com 15% de tungstato de cálcio (BDCaWO4) ou óxido de zircônio (BDZrO2), empregando sistemas de radiografia convencional e digital; e (2) as propriedades físico-químicas de tempo de presa, pH e solubilidade, e as propriedades biológicas de citocompatibilidade e potencial para induzir mineralização desses cimentos. Para a avaliação da radiopacidade, cada corpo de prova foi radiografado ao lado de uma escada de alumínio usando filme oclusal, placa de fósforo ou sensores digitais. As radiografias convencionais foram digitalizadas por câmera fotográfica ou scanner. Os valores médios de cinza dos materiais foram expressos em milímetros de alumínio (mm Al). A solubilidade foi avaliada após 7 dias de imersão dos espécimes em água destilada e expressa em percentagem de perda de massa. O tempo de presa foi avaliado empregando a agulha de Gillmore (105 ± 0,5 g) e o pH foi mensurado com um medidor de pH. A citocompatibilidade e a bioatividade celular foram avaliadas em células de linhagem osteoblástica (Saos-2) utilizando os ensaios de metiltetrazólio (MTT), vermelho neutro (NR), atividade de fosfatase alcalina (ALP) e coloração de vermelho de alizarina. Os dados foram avaliados utilizando ANOVA de um fator e pós-teste Tukey ou ANOVA de dois fatores e pós-teste de Bonferron... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: BiodentineTM (BD) presents bioactivity, biocompatibility and suitable physicochemical properties; however, it does not have adequate radiopacity. The objectives were to evaluate (1) the radiopacity of BD and BD associated with 15% calcium tungstate (BDCaWO4) or zirconium oxide (BDZrO2), employing conventional and digital radiography systems; and (2) the physicochemical properties of setting time, pH and solubility, and biological properties of cytocompatibility and potential to induce mineralization of these cements. For radiopacity evaluation, each cement specimen was radiographed alongside an aluminum step-wedge using occlusal film, photostimulable phosphor plates or digital sensors. The conventional radiographies were digitized by digital photographic camera or scanner. Mean grey values of materials were expressed in millimeters of aluminum (mm Al). Solubility was evaluated after 7 days of specimens' immersion in distilled water and expressed as percentage of mass loss. Setting time was evaluated employing a Gillmore needle (105 ± 0.5 g) and pH was evaluated with pH meter. The cytocompatibility and cell bioactivity were evaluated in osteoblasts-like cells (Saos-2) using methyl-thiazol-tetrazolium (MTT), neutral red (NR), alkaline phosphatase (ALP) activity and alizarin red staining assays. The data were evaluated using one-way ANOVA and Tukey post-test or two-way ANOVA and Bonferroni post-test (α=0.05). BD radiopacity was below 3 mm Al and BDZrO2 and BDCaWO4 was above 3 mm... (Complete abstract click electronic access below) / Mestre
24

Reação tecidual e potencial bioativo de cimentos endodônticos biocerâmicos em subcutâneo de ratos /

Silva, Evelin Carine Alves. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Cimentos à base de silicatos de cálcio são desenvolvidos para obturação de canais radiculares. Publicação 1: Este estudo avaliou propriedades biológicas dos cimentos experimentais (CE-1 e CE-2) compostos por silicatos de cálcio e com adição de hipoclorito de cálcio (CE-2), em comparação ao AH Plus (AHP) e TotalFill BC Sealer (TBC). A reação tecidual provocada pelos materiais no subcutâneo de ratos foi avaliada por meio da implantação de tubos de polietileno nos períodos de 7, 15, 30 e 60 dias. Cortes foram corados com hematoxilina e eosina (HE) para análises morfológica e do número de células inflamatórias/mm2(CI) e cortes foram utilizados para detecção de interleucina-6 (IL-6) e osteocalcina. Método de von Kossa foi realizado para identificação de depósitos de cálcio. Os dados foram submetidos aos testes ANOVA e Tukey, com significância de 5%. Aos 7 dias, CE-1, CE-2 e AHP apresentaram maior número de CI. AHP apresentou maior marcação para IL-6. Após 15 dias não houve diferença entre CE-2 e o grupo controle para IL-6. Aos 30 dias, AHP exibiu maior número de CI (p<0,0001) e CE-2 e o grupo controle os menores valores de CI e IL-6. Após 60 dias CE-2, TBC e controle apresentaram os menores valores (p<0,05). Os cimentos CE-1, CE-2 e TBC apresentaram estruturas positivas ao método von Kossa em todos os períodos observados e marcação positiva para osteocalcina. CE-2 apresentou quantidade de células positivas superior em todos os períodos quando comparado aos cimentos CE-1 e TBC (p< ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
25

Avaliação de diferentes tratamentos de superfícies de Ticp e Ti-6Al-4V-ELI : análises físicas, químicas e biológicas in vitro /

Cominotte, Mariana Aline. January 2020 (has links)
Orientador: Joni Augusto Cirelli / Resumo: A qualidade do tecido ósseo representa condição “sine qua non” para a estabilidade e longevidade de implantes biomédicos. Diante de fatores sistêmicos relacionados à insuficiência e/ou má qualidade do tecido ósseo peri-implantar, o desenvolvimento de superfícies de titânio com atividade osteogênica é amplamente incentivado na área da implantodontia. Sendo assim, este Estudo avaliou diferentes formas de tratamentos da superfície das amostras de titânio comercialmente puro (Ticp) e titânio liga 6Alumínio-4Vanádio, que visam o favorecimento dos mecanismos celulares de osteogênese. Este estudo foi divido em 2 capítulos. Na publicação 1 as amostras foram divididas em 3 grupos de acordo com os tratamentos (Grupo 1: Titânio comercialmente puro – MS; Grupo 2: Tratamento com NaOH - AES; Grupo 3: Tratamento com NaOH associado à deposição de Estrôncio (Sr) – Sr-AES. Os resultados demonstraram que as superfícies dos Grupos 2 e 3 apresentaram-se mais rugosas, quando avaliadas em perfilômetro, e mais hidrofílicas em teste de molhabilidade, em comparação às do Grupo 1 (p < 0.05, One Way Anova). As células em contato com a superfície do Grupo 3 apresentaram espraiamento celular mais evidente, em comparação aos Grupos 1 e 2, indicando que a adição do estrôncio às amostras foi favorável ao desenvolvimento das células precursoras ósseas. Na publicação, as amostras foram divididas em 3 grupos de acordo com os diferentes tratamentos. Grupo A: titânio comercialmente puro – Ticp; Grupo B: Ti-6Al-4V... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
26

Avaliação histomorfométrica da biocompatibilidade do enxerto bovino misto (OrthoGen®) em tecido subcutâneo e o potencial osteogênico em defeito ósseo craniano / Histomorphometric evaluation of biocompatibility of integral bovine graft (Orthogen®) implanted in subcutaneous tissue and osteogenic potential in cranial bone defect

Oliveira, Tamiris Vallim Zambaldi de 20 March 2014 (has links)
O desenvolvimento atual de materiais ósseo-substitutos com potencialidade de promover o fechamento completo de um defeito ósseo crítico tem levantado questões quanto à sua atuação biológica. Uma opção de material ósseo utilizado são os enxertos ósseos de origem animal, pois possuem propriedades físicoquímicas similares ao osso humano. O osso bovino misto que preserva a estrutura colagênica e o mineral ósseo tem sido proposto e utilizado como material ósseosubstituto. O objetivo desse estudo foi avaliar a biocompatibilidade e o potencial osteogênico de um enxerto bovino ósseo subistituto, OrthoGen® (Baumer S.A.), na forma de partículas (OGp) e blocos (OGb). Para a avaliação da biocompatibilidade, 100 mg de OrthoGen® nas formas de partícula e bloco, foram implantados no subcutâneo de ratos (n=25) e o tecido reacional foi avaliado aos 7, 14, 21, 30 e 60 dias (n=5 animais/período) após a implantação. Para a análise do potencial osteogênico foram implantados 100 mg de Orthogen® nas formas de partícula e bloco em defeito critico na calvária de ratos (n=30), e a formação óssea foi mensurada aos 1, 3 e 6 meses (n=10/período) após a implantação. A análise radiográfica e histomorfométrica revelaram que no tecido subcutâneo o OGb foi melhor aceito pelo organismo quando comparado ao OGp com uma frequência menor de células gigante multinucleadas entre os períodos avaliados (OGb 0,23% vs OGp 2,19%) e consequentemente uma média de reabsorção também menor (OGb 13% vs OGp 38%). Em ambos os implantes não foi encontrado focos de infiltrado inflamatório composto por leucócitos polimorfonucleares, linfócitos e plasmócitos. Na calvária o OGb mostrou níveis de reabsorção inferiores e uma maior taxa de formação óssea quando comparado ao OGp após 6 meses (OGb 70 mm³ vs OGp 17 mm³). Baseado no modelo experimental utilizado neste estudo, concluímos que ambas as formas do Orthogen® são biocompatíveis em tecido subcutâneo, no entanto, sua forma em bloco promove uma maior formação óssea, possuindo uma capacidade osteogênica superior à forma em partícula, no modelo experimental avaliado. / The current development of bone graft materials with the potential to promote the complete closure of a critical size bone defect has raised questions as to its biological activity. An option of bone material used, are animal bone grafts since the human bone have similar physicochemical properties. Among the materials is the integral bone substitute of bovine origin, which preserves the organic and inorganic compound of the bone tissue, has been proposed and used as bone graft. The aim of this study was to evaluate the biocompatibility and osteogenic potential of a new integral bone substitute OrthogenTM (Baumer S.A.) in the form of particles (OGp) and block (OGb). For biocompatibility evaluation, 100mg OrthogenTM was implanted into dorsal subcutaneous pocket of rat (n= 25) and the reactional tissue was analyzed at 7, 14, 21, 30 and 60 days (n=5animals/period) after implantation. For osteogenic potential evaluation, 100mg OrthogenTM was implanted into critical-size defect in parietal bones of rat (n=30) and the bone formation, biomaterial reabsorption, connective tissue formation and osteoclast activity was evaluated at 1, 3 and 6 months (n=10/period) after implantation. Radiographic and histomorphometrical analysis showed that, in the subcutaneous tissue the OGb was more accepted by the host compared to OGp, with lower density of the multinucleated giant cells (OGb 0.23% vs. OGp 2.19%) and consequently a lower rate of matrix resorption (OGb 13%, vs. OGp 38%). In both implants was not found focus of inflammatory infiltrated composed by polymorphonuclear leucocytes, lymphocytes and plasmocytes. In rat calvaria the OGb showed lower rate of reabsorption and more volume of bone formation compared to OGp after 6 months (OGb 70 mm3 vs OGp 17 mm3). Based on experimental models used in this study we concluded that both forms of the OrthogenTM was biocompatible in subcutaneous tissue, however, its form of porous block promoted greater bone formation and has a higher osteogenic capacity than the particle shape, in the evaluated experimental model.
27

Avaliação da influência da técnica de aplicação e manipulação na força de retenção de cimentos resinosos autoadesivos empregados na cimentação intrarradicular de pinos de fibra / Evaluation of the influence of application and handling technique in the retention strength of self-adhesive resin cements used in intra-radicular fiberglass posts

Shiratori, Fábio Kenji 09 April 2010 (has links)
Atualmente, existem cimentos resinosos que dispensam o uso prévio de sistemas adesivos (autoadesivos) e aliam as vantagens dos cimentos resinosos às dos cimentos não resinosos, sendo recomendados para todas as restaurações indiretas, inclusive a cimentação de pinos intrarradiculares. Devido à falta de conhecimento do comportamento desses cimentos perante as diferentes técnicas de manipulação e aplicação, o objetivo deste trabalho foi avaliar a força de retenção de 3 cimentos autoadesivos, quando empregados na cimentação de pinos intrarradiculares de fibra de vidro. Para isso, foram selecionados 45 caninos humanos, divididos aleatoriamente em três grupos (N=15) diferenciados pelos cimentos: Grupo I - BisCem (Bisco), Grupo II - Breeze (Pentron Clinical Technologies, LLC) e Grupo III Maxcem (Kerr). Esses grupos foram divididos em três subgrupos, variando a técnica de aplicação e de manipulação: Subgrupo A - Ponta automisturadora/Ponta aplicadora, Subgrupo B - Espatulação/Lentulo, Subgrupo C - Espatulação/Centrix. O teste de push-out foi realizado com uma velocidade de 1 mm/min, e a força de retenção foi expressa em Mega Pascal (MPa). O cimento Breeze apresentou os maiores resultados médios para os subgrupos A, B e C (12,27 ± 3,19 Mpa; 13,65 ± 2,51 MPa; 13,64 ± 3,65 MPa), quando comparados aos cimentos Biscem (7,25 ± 2,37 MPa; 13,37 ± 1,80 MPa; 9,48 ± 2,38 MPa), e Maxcem Elite (7,87 ± 1,12 MPa; 7,21 ± 1,43 MPa; 9,89 ± 1,43 MPa. Somente para o cimento Biscem houve diferença estatística significante entre seus subgrupos. Assim, pôde-se concluir que, de acordo com os resultados deste estudo, a técnica de aplicação e manipulação pode influenciar na resistência retentiva, dependendo do cimento autoadesivo utilizado. / Currently, there are resin cements that do not require prior use of adhesive systems (self-adhesive), and combine the advantages of resin cements with that of non-resin cements, and are recommended for all indirect restorations, including intraradicular cementation. Due to the lack of understanding about the behavior of these cements in the presence of the different handling and application techniques, the objective was to evaluate the retention strength of 3 self-adhesive cements, when used in cementing intra-radicular fiberglass posts. For this, 45 human canines were selected and divided randomly into three groups (N = 15) for different cements: roup I - Bisco (Bisco), Group II - Breeze (Pentron Clinical Technologies, LLC) and Group III - Maxcem (Kerr). These groups were divided into three sub-groups by varying the application and handling technique: Sub-group A - Automix/Point tip applicator, Sub-group B - Handmix/ Lentulo, Sub-group C Handmix/ Centrix. The test of push-out was performed with a speed of 1 mm / min, and the retention strength was expressed in Mega Pascal (MPa). The Breeze cement, showed the highest average for sub-groups A, B and C (12.27 ± 3.19 MPa, 13.65 ± 2.5 MPa, 13.64 ± 3.65 MPa)when compared to the Biscem cement (7.25 ± 2.37 MPa, 13.37 ± 1.80 MPa, 9.48 ± 2.38 MPa), and Maxcem Elite (7.87 ± 1.12 MPa, 7.21 ± 1 , 43 MPa, 9.89 ± 1.43 MPa. Only for the Biscem cement was there statistically significant difference between the sub-groups. Thus, one can conclude that according to the results of this study, the application and handling technique may influence the retentive strength depending on the self-adhesive cement used.
28

Análise biomecânica in vitro de pilares estéticos de zircônia personalizados e não personalizados / In vitro biomechanical analysis of customized and not customized aesthetic zircônia abutment

Moris, Izabela Cristina Mauricio 19 May 2015 (has links)
Atualmente os implantes passaram a ser uma opção viável de tratamento para se obter uma adequada reabilitação oral, sendo que a estética tem se tornado um fator de grande importância na Odontologia. Os pilares em zircônia tem-se apresentado como uma boa alternativa que vem preencher o fator estético, não contemplado pelos pilares metálicos. O objetivo deste estudo foi avaliar a resistência à fratura dos pilares de zircônia personalizados e não personalizados e o efeito da ciclagem termomecânica sobre a adaptação marginal, perda de torque e resistência à cimentação destes pilares. Para avaliar a resistência à fratura, 18 implantes cone morse foram utilizados e estes foram divididos em três grupos: GZr: 6 conjuntos implantes/pilares em zircônia; GZrp: 6 conjuntos implante/pilares em zircônia personalizados e GTi: 6 conjuntos implante/pilares em titânio (controle). Os conjuntos implante/pilar foram submetidos à carga compressiva oblíqua em máquina universal de ensaios, com célula de carga de 500kgf e velocidade de 0,5mm/min, em angulação de 30°. Para avaliar os efeitos da ciclagem termomecânica foram utilizados 24 implantes cone morse e estes foram divididos em três grupos: GZr: 8 conjuntos implantes/pilares em zircônia; GZrp: 8 conjuntos implante/pilares em zircônia personalizados e GTi: 8 conjuntos implante/pilares em titânio (controle). Os pilares foram instalados com o torque recomendado pelo fabricante (15Ncm). Coroas cerâmicas foram confeccionadas para todos os grupos. A adaptação marginal das coroas foi avaliada antes e após a ciclagem termomecânica e a resistência de cimentação das coroas foi avaliada após a ciclagem termomecânica através do ensaio de tração. Os conjuntos foram submetidos a 1.000.000 ciclos mecânicos e 8.400 ciclos térmicos. A análise estatística utilizada para o teste de resistência à fratura foi Anova com teste complementar de Tukey. O Grupo GZrp apresentou resistência a fratura significantemente maior que GZr (p=0,009) e o GZr foi semelhante ao GTi. Para a análise da perda de torque e adaptação marginal foi utilizado o modelo linear de efeitos mistos. Para a adaptação marginala análise estatatística revelou haver diferença entre os grupos GZrp e GTi (após ciclagem p=,010) porém não houve diferença dentro do mesmo grupo nos diferentes tempos (antes e após ciclagem termomecânica). Para a perda de torque a análise estatística revelou não haver diferenças significantes, antes e após a ciclagem termomecânica, dentro dos grupos, porém entre os grupos houve diferenças estatísticas entre GZr e Gti antes da ciclagem . Para a análise da resistência de cimentação das coroas foi utilizado ANOVA e este revelou não haver diferenças significantes entre os grupos. Sendo assim, conclui-se que a personalização dos pilares de zircônia não afeta suas propriedades mecânicas, e que o comportamento dos pilares de zircônia é semelhante aos pilares de titânio o que viabiliza o seu uso clínico. / Now implants have been a viable option of treatment for reaching an adequate oral rehabilitation, once the aesthetic have become a factor of great importance in Dentistry. The zirconia abutments have appeared as a good alternative to fill the aesthetic factor that is not present in the metallic abutments. The aim of the present study was to evaluate the fracture strength of customized and not customized zirconia abutments and the effect of thermomechanical cycling in the marginal fit, torque loss and cementation resistance of these abutments. For fracture strength evaluation, 18 morse taper implants were used and divided into three groups: GZr: 6 sets of implants/zirconia abutments; GZrp: 6 sets of implants/customized zirconia abutments and GTi: 6 sets of implants/titanium abutments (control). The sets were submitted to compressive oblique loading in universal testing machine, with a load cell of 500kgf and 0.5mm/min speed, in a 30 degree angulation. For evaluation of the thermomechanical cycling effect, 24 morse taper implants were used and divided into three groups: GZr: 8 sets implants/zirconia abutments; GZrp: 8 sets implants/customized zirconia abutments and GTi: 8 sets implants/titanium abutments (control). The abutments were installed with the torque recommended by the manufacturer (15Ncm). Ceramic crowns were made for all groups. The marginal fit of crowns was evaluated before and after thermomechanical cycling and the cementation resistance of crowns was evaluated after thermomechanical cycling by tensile strength test. The sets were submitted to 1,000,000 mechanical cycles and 8,400 thermal cycles. The fracture strength data were statistically analyzed by ANOVA and Tukey\'s test. The GZrp group presented fracture strength statistically greater than GZr (p=.009) and GZr was similar to GTi. Marginal fit and torque loss data were analyzed by mixed linear model. In the marginal fit, significant difference was noted between GZrp and GTi (after: p=.010), but no difference was noted in the group at different times (before and after thermomechanical cycling).For torque loss, no significant difference was noted before and after thermomechanical cycling in the groups, but significant difference was noted between Gzrp and GTi after thermomechanical cycling. Cementation resistance of crowns was analyzed by ANOVA and no significant difference was noted among the groups. Thus, it was concluded that customization of zirconia abutments does not affect their mechanical properties, and the behavior of zirconia abutments is similar to titanium ones, enabling its clinical use.
29

Estudo do processo de reparo ósseo em função de quatro biomateriais. Avaliação histomorfológica em tíbia de coelhos / Study of bone repair process in function of four biomaterials. Microscopy evaluation in rabbit tibias

Cavenago, Bruno Cavalini 23 May 2011 (has links)
Este estudo avaliou o processo de reparo ósseo em cavidades cirúrgicas de tamanho não crítico, quando preenchidas por diferentes biomateriais. Um defeito ósseo de 5 mm de diâmetro por 8mm profundidade foi criado em cada metáfise tibial de 27 coelhos machos. Foram estabelecidos 4 grupos com 12 cavidades por material. As cavidades foram preenchidas com matriz óssea bovina inorgânica, GenOx Inorg® (grupo 1), matriz óssea bovina orgânica, GenOx Org® (grupo 2), matriz óssea bovina composta, GenMix® (grupo 3) e sulfato de cálcio di-hidratado (Grupo 4). Adicionalmente, seis cavidades preenchidas com coágulo sanguíneo foram utilizadas como controle (grupo 5). Os animais foram mortos após 30, 60 e 90 dias e as amostras coletadas foram submetidas ao processamento histotécnico para obter cortes de 5 m de espessura, corados com hematoxilina e eosina. Foram realizadas análises histomorfológica descritiva e histomofométrica, que consistiu na mensuração da área de tecido ósseo neoformado. Os dados obtidos foram submetidos ao teste estatístico de Kruskal-Wallis e Dunn. Aos 30 e 60 dias a área de tecido ósseo neoformado ocorreu de forma semelhante entre todos os grupos (P > 0,05). No período de 90 dias houve diferença significativa entre os grupos 2 e 4, bem como entre os grupos 4 e 5. Ao realizar a análise estatística de cada grupo em função dos 3 períodos experimentais, constatou-se que nos grupos 1, 2 e 3 a área de tecido ósseo neoformado aos 30 dias foi menor (P < 0,05) em relação a 60 e 90 dias. No grupo 4, ocorreu diferença significativa entre os períodos de 30 e 90 dias, já no grupo 5 houve diferença significante ao comparar 30 e 60 dias. Com base na microscopia observamos que os biomateriais estudados não inibiram o processo de reparo; o GenOx Inorg e a matriz inorgânica presente no GenMix exibiram características morfológicas de propriedade osteocondutora, mais intensa no primeiro grupo. O GenOx Org e o sulfato de cálcio di-hidratado apresentaram-se completamente reabsorvidos aos 30 dias. Foi possível concluir que os valores neoformativos proporcionados pelo GenMix não foram significativamente superiores, àqueles obtidos pelo GenOx Inorg, GenOx Org e sulfato de cálcio di-hidratado. Os diferentes biomateriais utilizados não apresentaram resultados superiores ao coágulo sanguíneo, exceto o sulfato de cálcio di-hidratado aos 90 dias. / This study evaluated the bone healing process in non-critical surgical cavity size, when grafted with different biomaterials. A 5mm wide and 8mm long defect were created in each tibial metaphysis of 27 male rabbits. Four groups of 12 cavities per material were established. The cavities were filled with deproteinized bovine bone, GenOx Inorg ® (group 1), demineralized bovine bone, GenOx Org® (group 2), composite bovine bone, GenMix® (group 3) and di-hydrate calcium sulfate (group 4). Additionally 6 cavities were filled with blood clot for control purposes (group 5). At 30, 60 and 90 days after surgery the animals were killed and the grafted areas were submitted to histologically process to obtain a 5 m thickness sections and stained with hematoxylin and eosin. The specimens were proceeded to descriptive and quantitative microscopic analysis, by measuring the area of new formed bone. The results were statistically analyzed by the Kruskal-Wallis and Dunn tests. At 30 and 60 days the area of new bone formation was similar among all groups (P > 0,05). In 90 days period there was a significant difference between groups 2 and 4, as well as groups 4 and 5. Performing the statistical analysis of each group in relation to the 3 experimental periods, it was found that in groups 1, 2 and 3 the area of new bone formed at 30 days was lower (P < 0,05) than 60 and 90 days. There was a significant difference in group 4 comparing the periods 30 and 90 days and in group 5 between 30 and 60 days. Based on microscopy findings we observed that the biomaterials studied did not inhibit the repair process; the GenOx Inorg and inorganic matrix present in GenMix exhibited morphological characteristics of osteoconductive property, more intense in the first one. The GenOx Org and di-hydrate calcium sulfate were completely reabsorbed within 30 days. It was concluded that the values of new bone formed area provided by GenMix were not significantly higher than obtained by GenOx Inorg, GenOx Org and di-hydrate calcium sulfate. The different biomaterials used did not show better results than blood clot, except di-hydrate calcium sulfate at 90 days.
30

Avaliação microscópica da reação tecidual em subcutâneo de rato frente a cimentos Portland contendo diferentes concentrações de arsênico / Microscopic evaluation of the tissue reaction in subcutaneous of rats to Portland cements containing different arsenic concentrations

Minotti, Paloma Gagliardi 20 May 2011 (has links)
O MTA (Agregado Trióxido Mineral) tem sido utilizado na endodontia com diferentes finalidades terapêuticas. Essencialmente ele é constituído pelo cimento Portland acrescido de um radiopacificador. Entre seus componentes, é destacada a presença do arsênico, o qual sofre variação de concentração em função da origem do calcário. A dúvida é que se diferentes concentrações de arsênico representam alguma influência na sua biocompatibilidade. O objetivo deste estudo foi avaliar, microscopicamente, a reação tecidual em subcutâneo de ratos frente a cimentos Portland contendo diferentes concentrações de arsênico. Foram utilizados 36 ratos Wistar albinos, distribuídos em 4 grupos experimentais segundo o material empregado perfazendo um total de 6 implantes por período (15, 30 e 60 dias). A lateral dos tubos serviram como grupo controle. Após 15, 30 e 60 dias, os animais foram mortos e os espécimes foram preparados histotecnicamente para análise microscópica. Os dados da avaliação morfométrica foram submetidos à análise de variância a dois critérios (ANOVA) e teste de Tukey para a comparação (p<0,05). Os resultados mostraram uma maior densidade de volume de células inflamatórias aos 15 dias, com redução dessa densidade com o passar do tempo para todos os materiais. Os resultados da análise descritiva mostraram inflamação crônica induzida pelos materiais, com intensidade de leve a moderada, e organização de uma cápsula fibrosa ao redor de todos os espécimes e em todos os períodos. Os cimentos analisados produziram respostas inflamatórias semelhantes, mesmo apresentando quantidades diferentes de arsênico na composição, apenas com diferença estatisticamente significante entre o cimento Portland cinza Votoran e os demais cimentos nos três períodos estudados. / The MTA (Mineral Trioxide Aggregate) has been used in Endodontics for different therapeutic purposes. Essentially, it is composed of Portland cement with addition of a radiopacifier. Its components include arsenic, whose concentration is variable according to the origin of the calcareous. There is doubt whether different arsenic concentrations might influence its biocompatibility. This microscopic study evaluated the reaction of subcutaneous tissue of rats to Portland cements containing different arsenic concentrations. The study was conducted on 36 albinus Wistar rats, divided in 12 animals for each study group. Each animal received two implants of polyethylene tubes, completely filled with the test cements, and the lateral aspect of the tubes was taken as control group. The animals were killed after 15, 30 and 60 days and the specimens were submitted to histotechnical preparation for microscopic analysis. Data of the morphometric analysis were submitted to two-way analysis of variance (ANOVA) and the Tukey test for comparison (p<0.05). The results evidenced greater density of volume of inflammatory cells at 15 days, which was reduced with time for all materials. The results of this descriptive analysis demonstrated chronic inflammation induced by the materials, of mild to moderate intensity, and organization of a fibrous capsule around all specimens and in all periods. The cements induced similar tissue responses, despite the different arsenic concentrations in their composition.

Page generated in 0.1149 seconds