• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação das respostas cardiopulmonares entre o shuttle walk test incremental e teste ergoespirométrico em esteira em pacientes hemiparéticos decorrente de AVC / Comparison of cardiopulmonary responses to the shuttle walk test and treadmill stress test in patients with hemiparetic stremming from a stroke

Sousa, Maria Helena Gomes de 28 February 2018 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-19T17:49:49Z No. of bitstreams: 1 Maria Helena Gomes de Sousa.pdf: 938639 bytes, checksum: 60ae02f298c21e9935dfa190fc6ea44b (MD5) / Made available in DSpace on 2018-07-19T17:49:49Z (GMT). No. of bitstreams: 1 Maria Helena Gomes de Sousa.pdf: 938639 bytes, checksum: 60ae02f298c21e9935dfa190fc6ea44b (MD5) Previous issue date: 2018-02-28 / Ergospirometric test, gold standard evaluation of cardiorespiratory fitness, is not an economically accessible and easy to apply test, especially for patients with Cerebral Vascular Accident (CVA) sequelae. Thus, field tests such as the Shuttle Walk Test Incremental (SWTI) may be another option for evaluation of cardiorespiratory function. Objective: compare the ventilatory, metabolic and cardiovascular responses obtained by the SWT and ergospirometric test, in hemiparetics due to stroke. Secondary objective was compared with the results of the ventilation evaluations with mild, moderate, marked and severe motor impairment of hemiparetic patients. Methodology: transversal study, with 20 hemiparetic subjects, motor impairment (05 mild, 04 moderate, 05 severe, 06 severe), 58 ± 10 years old, 08 women and 12 men. The VO2maximum (VO2), ventilatory (VE), desaturation, heart rate (HR) and blood pressure (BP), during the SWTI and ergospirometry, were evaluated in two days, 48h interval. Results: SpO2 was similar (97 [96-98]; 97 [94-97]) respectively in SWT and ergospirometry. VO2Pico metabolic variables (18 ± 4, 24 ± 4), cardiac FCPic (101 ± 17, 115 ± 15), systolic BP (140 [140-147], 160 [140-160]) and diastolic (2 ± 1, 3 ± 1), fatigue (2 [1-4], 4 [2-6]) and distance traveled (248 ± 154, 409 ± 1) 216). Comparison between groups of motor severity: ergospirometry showed variance in VO2peak and distance traveled between the light and severe group (p <0.05); others did not show significant differences. No SWTI, VO2Pico presented the difference between the moderate and striking groups (p <0.05) and the distance traveled between the light, striking and severe groups (p <0.05). Conclusion: SWTI is not similar to ergospirometry in the hemiparetic population due to stroke. Severe patients have poorer performance in both tests compared to the mild and moderate group, according to a Fugl-Meyer scale. / Teste ergoespirométrico, avaliação padrão ouro da aptidão cardiorrespiratória, não é um teste economicamente acessível e de fácil aplicabilidade, especialmente para pacientes com sequela de Acidente Vascular Cerebral (AVC). Assim, testes de campo como o Shuttle Walk Test Incremental(SWTI) podem ser outra opção de avaliação da função cardiorrespiratória. Objetivo: Comparar as respostas ventilatórias, metabólicas e cardiovasculares, obtidas pelo SWT e teste ergoespirométrico, em hemiparéticos decorrente de AVC. Objetivo secundário foi comparar os resultados das avaliações ventilatórias com o comprometimento motor leve, moderado, marcante e severo, dos pacientes hemiparéticos. Metodologia: estudo transversal, com 20 indivíduos hemiparéticos, comprometimento motor (05 leves, 04 moderados, 05 marcantes, 06 severos), 58±10 anos, 08 mulheres e 12 homens. Foram avaliados o consumo do VO2máximo(VO2), ventilação(VE), dessaturação, frequência cardíaca(FC) e pressão arterial(PA), durante o SWTI e ergoespirometria, realizados em dois dias, intervalo de 48h. Resultados: SpO2 foi semelhante (97[96-98]; 97[94-97]) respectivamente no SWT e ergoespirometria. Foram diferentes: as variáveis metabólicas VO2Pico (18±4; 24±4), cardíacas FCPico(101±17; 115±15), PA Sistólica(140[140-147]; 160[140-160]) e diastólica(85±6; 90±12), esforço percebido dispnéia (2±1; 3±1), fadiga(2[1-4]; 4[2-6]) e distância percorrida(248±154; 409±216). Comparação entre grupos de gravidade motora: ergoespirometria mostrou variância no VO2pico e distância percorrida entre o grupo leve e severo (p<0,05); demais não mostraram diferenças significativas. No SWTI, o VO2Pico apresentou diferença entre os grupos moderado e marcante(p<0,05) e na distância percorrida entre os grupos leve, marcante e severo(p<0,05). Conclusão: O SWTI não é similar à Ergoespirometria na população hemiparética decorrente de AVC. Os paciente severos tem menor desempenho em ambos os testes em comparação com o grupo leve e moderado, de acordo com a escala de Fugl-Meyer.

Page generated in 0.1339 seconds