• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 9
  • 9
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Verbal Learning and Memory Abilities in Children with Brain Tumors: The Role of the Third Ventricle Region

Micklewright, Jackie L 12 January 2006 (has links)
The third ventricle region houses several neuroanatomical structures that are primary components of the human memory system, and provides pathways through which these brain regions communicate with critical regions of the frontal and medial temporal lobes. Archival data was obtained for 42 children with cerebellar or third ventricle tumors, and was examined for tumor and treatment related confounds. Children with third ventricle tumors were hypothesized to exhibit; 1) better performance on a measure of auditory attention, 2) greater impairment in learning across trials, 3) greater memory loss over a 20-minute delay, and 4) greater impairment across delayed memory tests than the cerebellar group. Children with third ventricle tumors demonstrated significantly better auditory attention, but greater impairments in verbal learning, and greater verbal memory loss following a 20-minute delay. In contrast, children with third ventricle tumors did not demonstrate significantly greater memory impairments across long delay memory tests.
2

Estudo da anatomia endoscópica ventricular em cadáveres humanos brasileiros não fixados para realização de terceiro ventriculostomia / Study of ventricular endoscopic anatomy on Brazilian human cadavers non-fixed for the performance of the third ventriculostomy

Romero, Alicia Del Carmen Becerra 27 August 2010 (has links)
INTRODUÇÃO: O objetivo desta pesquisa foi medir, através da endoscopia, o plexo corióideo no forame interventricular e estruturas no assoalho do terceiro ventrículo, bem como a distância entre as artérias comunicantes posteriores e comparar essas variáveis. MÉTODOS: Estudo observacional, prospectivo realizado em 37 cérebros de cadáveres humanos adultos, de ambos os sexos, no Serviço de Verificação de Óbitos da Universidade de São Paulo, em abril de 2008, utilizando neuroendoscópio rígido. As imagens endoscópicas foram gravadas, corrigidas para distorção e mensuradas. A medida macroscópica entre as artérias comunicantes posteriores foi realizada após o estudo endoscópico. RESULTADOS: As medidas do plexo corióideo no forame interventricular, a distância látero-lateral dos corpos mamilares, a distância do recesso do infundíbulo até os corpos mamilares e do triângulo de segurança no túber cinéreo foram 1,71 mm (±0,77 mm), 2,23 mm (±0,74 mm), 3,22 mm (±0,82 mm), 3,69 mm2 (±2,09 mm2), respectivamente. O aspecto do assoalho do terceiro ventrículo e a distância interna dos corpos mamilares foi 84% opaco e 89% ausente, respectivamente. A distância média entre as artérias comunicantes posteriores foi de 12,5 mm (±2,3 mm). Associações entre translucidez do assoalho do terceiro ventrículo com as seguintes variáveis: distância láterolateral e distância interna dos corpos mamilares, assim como idade, foram identificadas. CONCLUSÕES: Até esta pesquisa, não existiam medidas sobre o plexo corióideo no forame interventricular e distância entre as artérias comunicantes posteriores na região dos corpos mamilares. As variáveis restantes, quando comparadas com a literatura, foram em maior número e em cérebros normais / INTRODUCTION: the objective of this research was to measure, through endoscopy, the interventricular foramen choroid plexus and the third ventricle floor structures, as well the distance between the communicating posterior arteries and compare these variables. METHODS: an observational, prospective study was conducted in 37 brains of adult human cadavers, of both sexes at the Death Check Unit of the University of São Paulo, in April 2008 by means of the rigid neuroendoscope. The endoscopic images were recorded, corrected for distortion and measured. The macroscopic measure between the communicating posterior arteries was performed after the endoscopic study. RESULTS: The measures of the interventricular foramen choroid plexus, the latero-lateral distance of mammillary bodies, the distance from the infundibular recess to the mammillary bodies, safety triangle in the tuber cinereum were 1.71 mm (±0.77 mm), 2.23 mm (±0.74 mm), 3.22 mm (±0.82 mm), 3.69 mm2 (±2.09 mm2), respectively. The aspect of the third ventricle floor and the internal distance of the mammillary bodies was 84% opaque and 89% absent, respectively. The mean distance between the communicating posterior arteries was 12.5 mm (±2.3 mm). Associations between the translucent floor of the third ventricle with the following variables: latero-lateral distance and internal distance of the mammillary bodies, as well as age were identified. CONCLUSIONS: Up this research, there was no account on the measures of the interventricular foramen choroid plexus and the distance between communicating posterior arteries at the level of the mammillary bodies. The remaining variables were in greater number and in normal brains, as compared with the literature
3

Estudo da anatomia endoscópica ventricular em cadáveres humanos brasileiros não fixados para realização de terceiro ventriculostomia / Study of ventricular endoscopic anatomy on Brazilian human cadavers non-fixed for the performance of the third ventriculostomy

Alicia Del Carmen Becerra Romero 27 August 2010 (has links)
INTRODUÇÃO: O objetivo desta pesquisa foi medir, através da endoscopia, o plexo corióideo no forame interventricular e estruturas no assoalho do terceiro ventrículo, bem como a distância entre as artérias comunicantes posteriores e comparar essas variáveis. MÉTODOS: Estudo observacional, prospectivo realizado em 37 cérebros de cadáveres humanos adultos, de ambos os sexos, no Serviço de Verificação de Óbitos da Universidade de São Paulo, em abril de 2008, utilizando neuroendoscópio rígido. As imagens endoscópicas foram gravadas, corrigidas para distorção e mensuradas. A medida macroscópica entre as artérias comunicantes posteriores foi realizada após o estudo endoscópico. RESULTADOS: As medidas do plexo corióideo no forame interventricular, a distância látero-lateral dos corpos mamilares, a distância do recesso do infundíbulo até os corpos mamilares e do triângulo de segurança no túber cinéreo foram 1,71 mm (±0,77 mm), 2,23 mm (±0,74 mm), 3,22 mm (±0,82 mm), 3,69 mm2 (±2,09 mm2), respectivamente. O aspecto do assoalho do terceiro ventrículo e a distância interna dos corpos mamilares foi 84% opaco e 89% ausente, respectivamente. A distância média entre as artérias comunicantes posteriores foi de 12,5 mm (±2,3 mm). Associações entre translucidez do assoalho do terceiro ventrículo com as seguintes variáveis: distância láterolateral e distância interna dos corpos mamilares, assim como idade, foram identificadas. CONCLUSÕES: Até esta pesquisa, não existiam medidas sobre o plexo corióideo no forame interventricular e distância entre as artérias comunicantes posteriores na região dos corpos mamilares. As variáveis restantes, quando comparadas com a literatura, foram em maior número e em cérebros normais / INTRODUCTION: the objective of this research was to measure, through endoscopy, the interventricular foramen choroid plexus and the third ventricle floor structures, as well the distance between the communicating posterior arteries and compare these variables. METHODS: an observational, prospective study was conducted in 37 brains of adult human cadavers, of both sexes at the Death Check Unit of the University of São Paulo, in April 2008 by means of the rigid neuroendoscope. The endoscopic images were recorded, corrected for distortion and measured. The macroscopic measure between the communicating posterior arteries was performed after the endoscopic study. RESULTS: The measures of the interventricular foramen choroid plexus, the latero-lateral distance of mammillary bodies, the distance from the infundibular recess to the mammillary bodies, safety triangle in the tuber cinereum were 1.71 mm (±0.77 mm), 2.23 mm (±0.74 mm), 3.22 mm (±0.82 mm), 3.69 mm2 (±2.09 mm2), respectively. The aspect of the third ventricle floor and the internal distance of the mammillary bodies was 84% opaque and 89% absent, respectively. The mean distance between the communicating posterior arteries was 12.5 mm (±2.3 mm). Associations between the translucent floor of the third ventricle with the following variables: latero-lateral distance and internal distance of the mammillary bodies, as well as age were identified. CONCLUSIONS: Up this research, there was no account on the measures of the interventricular foramen choroid plexus and the distance between communicating posterior arteries at the level of the mammillary bodies. The remaining variables were in greater number and in normal brains, as compared with the literature
4

Spatio-temporal dynamics in the anchoring of cilia

Kapoor, Shoba 20 September 2019 (has links)
No description available.
5

Third Ventricle Width as a Metric for Fast and Efficient Detection of Atrophy in Traumatic Brain Injury

Finuf, Christopher Scott 01 December 2015 (has links) (PDF)
In an average year more than 1.7 million people will experience a traumatic brain injury (TBI) in the United States. It is known that atrophy occurs across a spectrum for TBI patients, ranging from mild to severe. Current conventional magnetic resonance imaging (MRI) methods are inconsistent in detecting this atrophy on the milder end of the spectrum. Also more contemporary imaging tools, although efficient, are too time consuming for clinical applicability. It is for these reasons that a quick and efficient measurement for detecting this atrophy is needed by clinicians. The measuring of third ventricle width had the potential to be this measurement, since it is known that ventricular dilation is an indirect measure of brain atrophy. This study used two different data sets acquired at multiple sites. A total of 152 TBI patients' MRI scans were analyzed with diagnosis ranging from mild to severe. They have been age matched with 97 orthopedic injury controls. All scans were analyzed using Freesurfer® auto-segmentation software to acquire cortical, subcortical, and ventricular volumes. These metrics were then used as a standard of efficacy which we tested the new third ventricle width protocol against. There was no statistically significant difference between the overall TBI group and OI group (Welch's F(1,238.435) = 1.091, p= .267). The complicated mild injury subgroup was significantly increased from the mild subgroup (p= .001, d= .87). The grand average third ventricle width measurement was the best prognosticator of all measures analyzed despite only predicting 35.1% of cases correctly. The findings suggest that the third ventricle width measurement is insensitive to atrophy between all groups as hypothesized.
6

Avaliação anatômica comparativa dos acessos transcorioideo e transforniceal transcorioideo ao terceiro ventrículo / Comparative anatomical assessment of transchoroidal approach and transforniceal transchoroidal approach to the third ventricle

Araujo, João Luiz Vitorino 20 June 2016 (has links)
Introdução: O acesso ao terceiro ventrículo constitui verdadeiro desafio ao neurocirurgião. Nesse contexto, estudos anatômicos e morfométricos são úteis para estabelecer as limitações e as vantagens de determinado acesso cirúrgico. O acesso transcorioideo é versátil e promove exposição adequada da região média e posterior do terceiro ventrículo. Entretanto, a coluna do fórnice limita a exposição da região anterior do terceiro ventrículo. Há evidências de que a secção ipsilateral da coluna do fórnice tenha pouca repercussão na função cognitiva. Esta tese compara a exposição anatômica proporcionada pelo acesso transforniceal transcorioideo com o do acesso transcorioideo e realiza avaliação morfométrica de estruturas relevantes e comuns aos dois acessos. Material e métodos: A exposição anatômica proporcionada pelos acessos transcaloso transcorioideo e transcaloso transforniceal transcorioideo foram comparadas em oito cadáveres não submetidos à conservação, utilizando o sistema de neuronavegação (Artis, Brasília, Brasil), para aferir a área de trabalho, a área de exposição microcirúrgica, a exposição angular no plano longitudinal e transversal de dois alvos anatômicos (túber cinéreo e aqueduto cerebral). Adicionalmente, foram quantificados a espessura do parênquima do lobo frontal direito, a espessura do tronco do corpo caloso, o diâmetro longitudinal do forame interventricular, a distância de trabalho da superfície cortical ao túber cinéreo e a distância de trabalho da superfície cortical até o aqueduto cerebral. Os valores obtidos foram submetidos a análise de estatística utilizando o teste de Wilcoxon. Resultados: Na avaliação quantitativa, o acesso transforniceal transcorioideo proporcionou maior área de trabalho (transforniceal transcorioideo = 150,299 +/- 11,147 mm2; transcorioideo = 121,421 +/- 7,698 mm2; p < 0,05), maior área de exposição microcirúrgica (transforniceal transcorioideo = 100,920 +/- 8,764 mm2; transcorioideo = 79,944 +/- 4,954 mm2; p < 0,05), maior área de exposição angular no plano longitudinal para o túber cinéreo (transforniceal transcorioideo = 70,898 +/- 6,598 graus; transcorioideo = 63,838 +/- 5,770 graus; p < 0,05) e maior área de exposição angular no plano longitudinal para o aqueduto cerebral (transforniceal transcorioideo = 61,806 +/- 6,406 graus; transcorioideo = 54,998 +/- 5,102 graus; p < 0,05) em comparação com o acesso transcorioideo. Nenhuma diferença foi observada na exposição angular ao longo do eixo transversal para os dois alvos anatômicos (túber cinéreo e aqueduto cerebral) (p > 0,05). A espessura média do lobo frontal direito foi de 34,869 +/- 3,439 mm, a espessura do tronco caloso foi 10,085 +/- 1,172 mm, o diâmetro do forame interventricular foi de 4,628 +/- 0,474 mm, a distância da superfície cortical ao túber cinéreo foi de 69,315 +/- 4,564 mm e a distância da superfície cortical ao aqueduto cerebral foi de 75,654 +/- 4,950 mm. Na avaliação qualitativa, observamos que o acesso transforniceal transcorioideo permitiu incremento da visualização das estruturas da região anteroinferior do terceiro ventrículo. Não houve diferença quanto à exposição das estruturas da região média e posterior em ambos os acessos. Conclusões: O acesso transforniceal transcorioideo propicia maior exposição cirúrgica da região anterior do terceiro ventrículo em comparação com aquela oferecida pelo acesso transcorioideo. O estudo morfométrico estabeleceu valores médios das estruturas anatômicas comuns aos dois acessos na população estudada / Introduction: Approaches to the third ventricle constitute a formidable challenge to the neurosurgeon and, in this context, anatomical and morphometric studies are useful to establish the limitations and advantages of certain surgical approaches. The transchoroidal approach is a versatile one that promotes adequate exposure of the middle and posterior regions of the third ventricle. However, the column of fornix limits the exposure of the anterior third ventricle region. There is evidence that the ipsilateral section of the column of fornix has little effect on the cognitive function. This thesis compares the anatomical exposure using the transchoroidal transforniceal technique with the transchoroidal approach, and performs morphometric assessment of relevant structures common to both approaches. Material and methods: The anatomical exposure achieved through the transchoroidal transcallosal approach and transchoroidal transforniceal transcallosal were compared in 8 fresh cadavers using the neuronavigation system (Artis, Brasilia, Brazil), to assess the working area, microsurgical exposure area, to quantify the angular exposure in the longitudinal and cross-sectional planes to two anatomical targets (tuber cinereum and cerebral aqueduct), to measure the thickness of the right frontal lobe parenchyma, corpus callosum body thickness, longitudinal diameter of the interventricular foramen, working distance from the cortical surface to the tuber cinereum and working distance from the cortical surface to the cerebral aqueduct. The values obtained were submitted to statistical analysis using Wilcoxon\'s test. Results: In the quantitative assessment, the transchoroidal transforniceal approach provided: larger working area (transchoroidal transforniceal = 150.299 +/- 11.147 mm2; transchoroidal = 121.421 +/- 7.698 mm2; p < 0.05), larger area of microsurgical exposure (transforniceal transchoroidal = 100.920 +/- 8.764 mm2; transchoroidal = 79.944 +/- 4.954 mm2; p < 0.05), larger area of angular exposure in the longitudinal plane to the tuber cinereum (transchoroidal transforniceal = 70.898 +/- 6.598 degrees; transchoroidal = 63.838 + / - 5,770 degrees; p < 0.05) and larger area of angular exposure in the longitudinal plane to the cerebral aqueduct (transforniceal transchoroidal = 61.806 +/- 6.406 degrees; transchoroidal = 54.998 +/- 5.102 degrees; p < 0.05) when compared to the transchoroidal approach. No differences were observed in the angular exposure along the cross-sectional axis for both anatomical targets (tuber cinereum and cerebral aqueduct) (p > 0.05). The mean thickness of the right frontal lobe was 34.869 +/- 3.439 mm, the thickness of the corpus callosum body was 10.085 +/- 1.172 mm, the diameter of the interventricular foramen was 4,628 +/- 0,474 mm, the distance from the cortical surface to the tuber cinereum was 69.315 +/- 4.564 mm, and the distance from the cortical surface to the cerebral aqueduct was 75.654 +/- 4.950 mm. In the qualitative assessment, we observed that the transforniceal transchoroidal approach allowed better visualization of the structures in the anterior third ventricle region. There was no difference regarding exposure of structures in the middle and posterior regions with both access. Conclusions: The transforniceal transchoroidal approach provides greater surgical exposure of the anterior third ventricle region than that obtained with the transchoroidal approach. The morphometric study established mean values of anatomical structures that are common to both approaches in the assessed population
7

Avaliação anatômica comparativa dos acessos transcorioideo e transforniceal transcorioideo ao terceiro ventrículo / Comparative anatomical assessment of transchoroidal approach and transforniceal transchoroidal approach to the third ventricle

João Luiz Vitorino Araujo 20 June 2016 (has links)
Introdução: O acesso ao terceiro ventrículo constitui verdadeiro desafio ao neurocirurgião. Nesse contexto, estudos anatômicos e morfométricos são úteis para estabelecer as limitações e as vantagens de determinado acesso cirúrgico. O acesso transcorioideo é versátil e promove exposição adequada da região média e posterior do terceiro ventrículo. Entretanto, a coluna do fórnice limita a exposição da região anterior do terceiro ventrículo. Há evidências de que a secção ipsilateral da coluna do fórnice tenha pouca repercussão na função cognitiva. Esta tese compara a exposição anatômica proporcionada pelo acesso transforniceal transcorioideo com o do acesso transcorioideo e realiza avaliação morfométrica de estruturas relevantes e comuns aos dois acessos. Material e métodos: A exposição anatômica proporcionada pelos acessos transcaloso transcorioideo e transcaloso transforniceal transcorioideo foram comparadas em oito cadáveres não submetidos à conservação, utilizando o sistema de neuronavegação (Artis, Brasília, Brasil), para aferir a área de trabalho, a área de exposição microcirúrgica, a exposição angular no plano longitudinal e transversal de dois alvos anatômicos (túber cinéreo e aqueduto cerebral). Adicionalmente, foram quantificados a espessura do parênquima do lobo frontal direito, a espessura do tronco do corpo caloso, o diâmetro longitudinal do forame interventricular, a distância de trabalho da superfície cortical ao túber cinéreo e a distância de trabalho da superfície cortical até o aqueduto cerebral. Os valores obtidos foram submetidos a análise de estatística utilizando o teste de Wilcoxon. Resultados: Na avaliação quantitativa, o acesso transforniceal transcorioideo proporcionou maior área de trabalho (transforniceal transcorioideo = 150,299 +/- 11,147 mm2; transcorioideo = 121,421 +/- 7,698 mm2; p < 0,05), maior área de exposição microcirúrgica (transforniceal transcorioideo = 100,920 +/- 8,764 mm2; transcorioideo = 79,944 +/- 4,954 mm2; p < 0,05), maior área de exposição angular no plano longitudinal para o túber cinéreo (transforniceal transcorioideo = 70,898 +/- 6,598 graus; transcorioideo = 63,838 +/- 5,770 graus; p < 0,05) e maior área de exposição angular no plano longitudinal para o aqueduto cerebral (transforniceal transcorioideo = 61,806 +/- 6,406 graus; transcorioideo = 54,998 +/- 5,102 graus; p < 0,05) em comparação com o acesso transcorioideo. Nenhuma diferença foi observada na exposição angular ao longo do eixo transversal para os dois alvos anatômicos (túber cinéreo e aqueduto cerebral) (p > 0,05). A espessura média do lobo frontal direito foi de 34,869 +/- 3,439 mm, a espessura do tronco caloso foi 10,085 +/- 1,172 mm, o diâmetro do forame interventricular foi de 4,628 +/- 0,474 mm, a distância da superfície cortical ao túber cinéreo foi de 69,315 +/- 4,564 mm e a distância da superfície cortical ao aqueduto cerebral foi de 75,654 +/- 4,950 mm. Na avaliação qualitativa, observamos que o acesso transforniceal transcorioideo permitiu incremento da visualização das estruturas da região anteroinferior do terceiro ventrículo. Não houve diferença quanto à exposição das estruturas da região média e posterior em ambos os acessos. Conclusões: O acesso transforniceal transcorioideo propicia maior exposição cirúrgica da região anterior do terceiro ventrículo em comparação com aquela oferecida pelo acesso transcorioideo. O estudo morfométrico estabeleceu valores médios das estruturas anatômicas comuns aos dois acessos na população estudada / Introduction: Approaches to the third ventricle constitute a formidable challenge to the neurosurgeon and, in this context, anatomical and morphometric studies are useful to establish the limitations and advantages of certain surgical approaches. The transchoroidal approach is a versatile one that promotes adequate exposure of the middle and posterior regions of the third ventricle. However, the column of fornix limits the exposure of the anterior third ventricle region. There is evidence that the ipsilateral section of the column of fornix has little effect on the cognitive function. This thesis compares the anatomical exposure using the transchoroidal transforniceal technique with the transchoroidal approach, and performs morphometric assessment of relevant structures common to both approaches. Material and methods: The anatomical exposure achieved through the transchoroidal transcallosal approach and transchoroidal transforniceal transcallosal were compared in 8 fresh cadavers using the neuronavigation system (Artis, Brasilia, Brazil), to assess the working area, microsurgical exposure area, to quantify the angular exposure in the longitudinal and cross-sectional planes to two anatomical targets (tuber cinereum and cerebral aqueduct), to measure the thickness of the right frontal lobe parenchyma, corpus callosum body thickness, longitudinal diameter of the interventricular foramen, working distance from the cortical surface to the tuber cinereum and working distance from the cortical surface to the cerebral aqueduct. The values obtained were submitted to statistical analysis using Wilcoxon\'s test. Results: In the quantitative assessment, the transchoroidal transforniceal approach provided: larger working area (transchoroidal transforniceal = 150.299 +/- 11.147 mm2; transchoroidal = 121.421 +/- 7.698 mm2; p < 0.05), larger area of microsurgical exposure (transforniceal transchoroidal = 100.920 +/- 8.764 mm2; transchoroidal = 79.944 +/- 4.954 mm2; p < 0.05), larger area of angular exposure in the longitudinal plane to the tuber cinereum (transchoroidal transforniceal = 70.898 +/- 6.598 degrees; transchoroidal = 63.838 + / - 5,770 degrees; p < 0.05) and larger area of angular exposure in the longitudinal plane to the cerebral aqueduct (transforniceal transchoroidal = 61.806 +/- 6.406 degrees; transchoroidal = 54.998 +/- 5.102 degrees; p < 0.05) when compared to the transchoroidal approach. No differences were observed in the angular exposure along the cross-sectional axis for both anatomical targets (tuber cinereum and cerebral aqueduct) (p > 0.05). The mean thickness of the right frontal lobe was 34.869 +/- 3.439 mm, the thickness of the corpus callosum body was 10.085 +/- 1.172 mm, the diameter of the interventricular foramen was 4,628 +/- 0,474 mm, the distance from the cortical surface to the tuber cinereum was 69.315 +/- 4.564 mm, and the distance from the cortical surface to the cerebral aqueduct was 75.654 +/- 4.950 mm. In the qualitative assessment, we observed that the transforniceal transchoroidal approach allowed better visualization of the structures in the anterior third ventricle region. There was no difference regarding exposure of structures in the middle and posterior regions with both access. Conclusions: The transforniceal transchoroidal approach provides greater surgical exposure of the anterior third ventricle region than that obtained with the transchoroidal approach. The morphometric study established mean values of anatomical structures that are common to both approaches in the assessed population
8

Modelo anatômico de ventriculomegalia para treinamento neuroendoscópico / Ventriculomegaly anatomical models for neuroendoscopy training

Ferreira, Christian Diniz 28 May 2015 (has links)
OBJETIVO: Desenvolver peças anatômicas que simulem uma condição real de ventriculomegalia para serem utilizadas como uma ferramenta no treinamento dos neurocirurgiões nas técnicas de neuroendoscopia e viabilizar estudo anatômico dos ventrículos. MÉTODO: Foram utilizadas vinte peças anatômicas de encéfalo de cadáveres de indigentes, com a aprovação do Comitê de Ética em pesquisa da FMUSP sob o número 046/10. As peças foram retiradas da base do crânio com a persistência da superfície óssea (parte da calvária) para serem submetidas aos seguintes procedimentos: canulação do IV ventrículo por meio da abertura mediana do IV ventrículo (forame de Magendie); tomografias pré-experimento e injeção de água destilada no sistema ventricular. A água injetada estava à temperatura ambiente e os cérebros foram resfriados até 4º C e, após 12 horas, foram congelados a uma temperatura de 0º C (no estado sólido) por 24 horas. Esses procedimentos foram realizados na frequência de três vezes. Após o experimento, foram realizadas tomografias pós-experimento e procedimentos neuroendoscópicos ventriculares. Foram excluídos encéfalos com lesões traumáticas ou antecedentes de enfermidades transmissíveis. Não foram critérios de exclusão o sexo e a idade. Foram avaliadas, nas imagens tomográficas, a variação pré e pós-experimento dos seguintes parâmetros: coeficiente corno frontal/diâmetro interno; índice de Evan; e tamanho do corno temporal. As análises estatísticas foram realizadas no programa SPSS (Statistical Package for the Social Sciences) versão 13, para ambos os grupos. RESULTADOS: A avaliação da relação Corno frontal/Diâmetro interno, antes e pós-experimento apresentou média de 11,98% e 19,46%, respectivamente. Estudo estatístico (t Student) mostrou diferença estatística (t= -5142, gl =19; p < 0,01). O Índice de Evan também apresentou diferença significativa (t = -5,172, gl = 9; p < 0,01) entre os resultados antes (média de 10,86%) e após experimento (média de 18,35%). A análise do tamanho do corno temporal mostrou diferença significativa entre os grupos antes e depois do experimento (t = -2,297, gl = 9; p< 0,01), indicando que o tamanho mediano do Corno Temporal é maior após o experimento (média de 2,65cm). CONCLUSÕES: A exploração das características físico-químicas anômalas da molécula da água pode nos fornecer um bom mecanismo expansor de cavidades ventriculares para a indução de ventriculomegalia em uma peça anatômica de encéfalo, em que o endoscópio poderá ser introduzido pelas vias habituais, podendo, assim, realizar observação anatômica e simular o procedimento cirúrgico com a mesma sensibilidade tátil que irá encontrar no procedimento real / PURPOSE: To develop anatomical models which simulate real conditions of ventriculomegaly and to use them as tools to train neuroendoscopic techniques and allow the study of the ventricles. METHODS: A total of twenty brains, with the approval of the Ethics in Research Committee from FMUSP (046/10) were used to perform this research. The brains were separated from the skull base, but keeping part of the calvaria, and then underwent the following procedures: cannulation of the fourth ventricle through the median open of the fourth ventricle (foramen of Magendie); CT scans performed before the experiment; and then injection of distilled water into the ventricular system. The water was injected at room temperature, and then the brains were cooled to 4ºC. After 12 hours, they were then frozen at 0ºC for 24 hours.These procedures were repeated three times. After the experiment,CT scans were performed after the injections and neuroendoscopic procedures. Brains, which had traumatic injuries or history of infectious diseases, were excluded. Gender and age were not exclusion criteria. The statistical analysis was performed with the SPSS program (Statistical Package for the Social Sciences) version 13, for both groups. To assess the variation of the frontal horn (FH)/internal diameter (ID) coefficient, such as Evan\'s index\'s variation, and to analyze the temporal horn (TH) size, thet-Student test was used. RESULTS: The results of the t-Student test showed that the FH/ID, with an average of 11.98% before the experiment, had significant difference (t = -5.142, gl = 19; p < 0.01) after the experiment, with an average of19.46%. The Evan\'s index also showed a significant difference (t = -5.172, gl = 9; p < 0,01) with an initial average of 10.86% and a final average of 18.35%. The analysis of the temporal horn size showed a significant difference between the size before and after the experiment (t = -2.297, gl = 9; p < 0.01), indicating the significant increase of the temporal horn (with an initial average of 0.02cm and a final average of 2.65cm). CONCLUSIONS: The use of the anomalous physical and chemical characteristics of water can provide us with a good expanding mechanism of the ventricular system, creating ventriculomegaly in anatomical models, allowing the endoscope to be introduced by the usual approaches, to perform anatomical observation, and to simulate a surgical procedure with the same sensitivity of a real procedure
9

Modelo anatômico de ventriculomegalia para treinamento neuroendoscópico / Ventriculomegaly anatomical models for neuroendoscopy training

Christian Diniz Ferreira 28 May 2015 (has links)
OBJETIVO: Desenvolver peças anatômicas que simulem uma condição real de ventriculomegalia para serem utilizadas como uma ferramenta no treinamento dos neurocirurgiões nas técnicas de neuroendoscopia e viabilizar estudo anatômico dos ventrículos. MÉTODO: Foram utilizadas vinte peças anatômicas de encéfalo de cadáveres de indigentes, com a aprovação do Comitê de Ética em pesquisa da FMUSP sob o número 046/10. As peças foram retiradas da base do crânio com a persistência da superfície óssea (parte da calvária) para serem submetidas aos seguintes procedimentos: canulação do IV ventrículo por meio da abertura mediana do IV ventrículo (forame de Magendie); tomografias pré-experimento e injeção de água destilada no sistema ventricular. A água injetada estava à temperatura ambiente e os cérebros foram resfriados até 4º C e, após 12 horas, foram congelados a uma temperatura de 0º C (no estado sólido) por 24 horas. Esses procedimentos foram realizados na frequência de três vezes. Após o experimento, foram realizadas tomografias pós-experimento e procedimentos neuroendoscópicos ventriculares. Foram excluídos encéfalos com lesões traumáticas ou antecedentes de enfermidades transmissíveis. Não foram critérios de exclusão o sexo e a idade. Foram avaliadas, nas imagens tomográficas, a variação pré e pós-experimento dos seguintes parâmetros: coeficiente corno frontal/diâmetro interno; índice de Evan; e tamanho do corno temporal. As análises estatísticas foram realizadas no programa SPSS (Statistical Package for the Social Sciences) versão 13, para ambos os grupos. RESULTADOS: A avaliação da relação Corno frontal/Diâmetro interno, antes e pós-experimento apresentou média de 11,98% e 19,46%, respectivamente. Estudo estatístico (t Student) mostrou diferença estatística (t= -5142, gl =19; p < 0,01). O Índice de Evan também apresentou diferença significativa (t = -5,172, gl = 9; p < 0,01) entre os resultados antes (média de 10,86%) e após experimento (média de 18,35%). A análise do tamanho do corno temporal mostrou diferença significativa entre os grupos antes e depois do experimento (t = -2,297, gl = 9; p< 0,01), indicando que o tamanho mediano do Corno Temporal é maior após o experimento (média de 2,65cm). CONCLUSÕES: A exploração das características físico-químicas anômalas da molécula da água pode nos fornecer um bom mecanismo expansor de cavidades ventriculares para a indução de ventriculomegalia em uma peça anatômica de encéfalo, em que o endoscópio poderá ser introduzido pelas vias habituais, podendo, assim, realizar observação anatômica e simular o procedimento cirúrgico com a mesma sensibilidade tátil que irá encontrar no procedimento real / PURPOSE: To develop anatomical models which simulate real conditions of ventriculomegaly and to use them as tools to train neuroendoscopic techniques and allow the study of the ventricles. METHODS: A total of twenty brains, with the approval of the Ethics in Research Committee from FMUSP (046/10) were used to perform this research. The brains were separated from the skull base, but keeping part of the calvaria, and then underwent the following procedures: cannulation of the fourth ventricle through the median open of the fourth ventricle (foramen of Magendie); CT scans performed before the experiment; and then injection of distilled water into the ventricular system. The water was injected at room temperature, and then the brains were cooled to 4ºC. After 12 hours, they were then frozen at 0ºC for 24 hours.These procedures were repeated three times. After the experiment,CT scans were performed after the injections and neuroendoscopic procedures. Brains, which had traumatic injuries or history of infectious diseases, were excluded. Gender and age were not exclusion criteria. The statistical analysis was performed with the SPSS program (Statistical Package for the Social Sciences) version 13, for both groups. To assess the variation of the frontal horn (FH)/internal diameter (ID) coefficient, such as Evan\'s index\'s variation, and to analyze the temporal horn (TH) size, thet-Student test was used. RESULTS: The results of the t-Student test showed that the FH/ID, with an average of 11.98% before the experiment, had significant difference (t = -5.142, gl = 19; p < 0.01) after the experiment, with an average of19.46%. The Evan\'s index also showed a significant difference (t = -5.172, gl = 9; p < 0,01) with an initial average of 10.86% and a final average of 18.35%. The analysis of the temporal horn size showed a significant difference between the size before and after the experiment (t = -2.297, gl = 9; p < 0.01), indicating the significant increase of the temporal horn (with an initial average of 0.02cm and a final average of 2.65cm). CONCLUSIONS: The use of the anomalous physical and chemical characteristics of water can provide us with a good expanding mechanism of the ventricular system, creating ventriculomegaly in anatomical models, allowing the endoscope to be introduced by the usual approaches, to perform anatomical observation, and to simulate a surgical procedure with the same sensitivity of a real procedure

Page generated in 0.1426 seconds