• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 43
  • 43
  • 38
  • 25
  • 22
  • 21
  • 19
  • 18
  • 16
  • 13
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Obten??o e Caracteriza??o F?sico-Qu?mica do Sistema Comp?sito PEG-TiO2

Maria, Roberta Patr?cia Medeiros de 24 February 2011 (has links)
Made available in DSpace on 2014-12-17T15:41:57Z (GMT). No. of bitstreams: 1 RobertaPMM_DISSERT.pdf: 3172444 bytes, checksum: 159d519d0473cdce848696ecb3f8e8f6 (MD5) Previous issue date: 2011-02-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Hybrid systems formed from polymers and transition metals have now their physical and chemical properties extensively investigated for use in electronic devices. In this work, Titanium Dioxide (TiO2) from the precursor of titanium tetrabutoxide and the composite system Poly(Ethylene Glycol)-Titanium Dioxide (TiO2-PEG) were synthesized by sol-gel method. The PEG as acquired and TiO2 and composites powders were analyzed by X-Ray Diffraction (XRD), Spectroscopy in the Infrared region with Fourier transform (IRFT), Thermogravimetric Analysis (TGA), Scanning Electron Microscopy (SEM) and Electrochemical Impedance Spectroscopy (EIS). In the XRD analysis were observed in the TiO2 crystal faces of one of its polymorphs - anatase phase, crystal planes in Poly (Ethylene Glycol) with considerable intensity and in the composite systems the mixture of crystal faces of their precursors isolated and reduction of crystallinity. The TG / DTG suggested increasing the thermal instability of PEG in the composite powders as TiO2 is incorporated into the system. Spectral analysis presented in the infrared overlapping bands for the polymer and metal oxide, reducing the intensity of symmetric stretching of ligand groups in the main chain polymer and angular deformations; were observed using SEM micrographs of the morphological changes suffered by composite systems with the variation of the oxide concentration. Analyses by impedance spectroscopy indicated that the increased conductivity in composite occurs in line with the addition of the metal oxide concentration in the composite system / Sistemas h?bridos formados a partir de pol?meros e metais de transi??o atualmente t?m suas propriedades f?sicas e qu?micas extensivamente investigadas para aplica??o em dispositivos eletr?nicos. Neste trabalho, o Di?xido de Tit?nio (TiO2) a partir do precursor Tetrabut?xido de Tit?nio e o sistema comp?sito Poli (Etileno Glicol)-Di?xido de Tit?nio (PEG-TiO2) foram sintetizados pelo m?todo sol-gel. O PEG como adquirido e os p?s de TiO2 e comp?sitos obtidos foram analisados por Difra??o de Raios X (DRX), Espectroscopia de Absor??o na regi?o do Infravermelho com Transformada de Fourier (EIV-TF), An?lise Termogravim?trica (TG), Microscopia Eletr?nica de Varredura (MEV) e Espectroscopia de Imped?ncia Eletroqu?mica (EIE). Nas an?lises por DRX foram observadas no TiO2, faces cristalinas de um de seus polimorfos fase anat?sio, planos cristalinos no PEG com intensidade substancial e nos sistemas comp?sitos a mistura de faces cristalinas dos seus precursores na forma isolada, bem como, redu??o da cristalinidade. As curvas TG/DTG sugeriram o aumento da instabilidade t?rmica do PEG nos p?s comp?sitos ? medida que TiO2 ? incorporado ao sistema. A an?lise espectral na regi?o do infravermelho apresentou sobreposi??o de bandas relativas ao pol?mero e ao ?xido met?lico, redu??o da intensidade de estiramentos sim?tricos dos grupos ligantes da cadeia principal polim?rica e deforma??es angulares; foram observadas atrav?s das micrografias de MEV modifica??es morfol?gicas sofridas pelos sistemas comp?sitos com a varia??o da concentra??o do ?xido. As an?lises por imped?ncia eletroqu?mica indicaram que o aumento da condutividade nos comp?sitos ocorre em conson?ncia com a adi??o da concentra??o do ?xido met?lico no sistema comp?sito
42

Desenho e Constru??o de um prot?tipo gerador de jato de plasma frio a press?o atmosf?rica para aplica??es biom?dicas

Nascimento Neto, Arlindo Balbino do 07 February 2014 (has links)
Made available in DSpace on 2014-12-17T14:58:24Z (GMT). No. of bitstreams: 1 ArlindoBNN_DISSERT.pdf: 2586996 bytes, checksum: 478bf85288aae614a5921757e3272558 (MD5) Previous issue date: 2014-02-07 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface / Pesquisas na busca por materiais com melhor desempenho para aplica??es biom?dicas s?o constantes. Assim, estudos recentes buscam o desenvolvimento de novas t?cnicas para modifica??es de superf?cies. O plasma a baixa press?o vem se destacando pela sua versatilidade e por ser ambientalmente correto, obtendo-se bons resultados na modifica??o das propriedades f?sico-qu?micas dos materiais. Por?m, esta t?cnica necessita de um sistema de v?cuo de alto custo e n?o ? capaz de gerar modifica??es superficiais em regi?es pontuais. Al?m disso, limita seu uso em materiais polim?ricos e termosens?veis, devido ?s altas temperaturas do processo. Diante disso, foram criadas novas t?cnicas capazes de gerar um plasma frio a press?o atmosf?rica (APPJ). Com o objetivo de realizar tratamentos superficiais em biomateriais em regi?es pontuais, foi constru?do um prot?tipo capaz de gerar um jato de plasma frio. O prot?tipo gerador de plasma consiste em uma fonte de alta tens?o, um bra?o suporte, um porta amostra e uma ponteira por onde passa o arg?nio ionizado. Dentro desta ponteira existe um tubo diel?trico e dois eletrodos. Neste estudo foram variados alguns par?metros como: posi??o entre eletrodos, tens?o e frequ?ncia el?trica para verificar o comportamento das descargas luminescentes. Tratou-se disco de tit?nio grau II polido e verificou-se a energia el?trica consumida, comprimento, intensidade e modifica??es superficiais do tit?nio. A energia consumida durante as descargas foram verificadas pelo m?todo da figura de Lissajous. Para verificar o comprimento dos jatos foi utilizado o software Image Pro Plus. As modifica??es na superf?cie do tit?nio foram verificadas por microscopia ?tica (MO) e de for?a at?mica (MFA). O trabalho mostrou que varia??es dos par?metros de tens?o, frequ?ncia e posi??o geom?trica entre os eletrodos influenciam na forma??o do jato de plasma. Foi poss?vel concluirque o jato de plasma pr?ximo ? temperatura ambiente e a press?o atmosf?rica foi capaz de provocar modifica??es superficiais no tit?nio
43

Estudo das ligas tit?nio-zirc?nio resultantes do processo de fundi??o plasma-skull para aplica??es como biomateriais

Montenegro, Ieda Nadja Silva 06 July 2007 (has links)
Made available in DSpace on 2014-12-17T15:42:01Z (GMT). No. of bitstreams: 1 IedaNSM.pdf: 5948604 bytes, checksum: dbf245a349dd04cff535e8ba2e89601d (MD5) Previous issue date: 2007-07-06 / The aim of this work was to study a series of 11 different compositions of Ti-Zr binary alloys resistance to aggressive environment, i. e., their ability to keep their surface properties and mass when exposed to them as a way to evaluate their performance as biomaterials. The first stage was devoted to the fabrication of tablets from these alloys by Plasma-Skull casting method using a Discovery Plasma machine from EDG Equipamentos, Brazil. In a second stage, the chemical composition of each produced tablet was verified. In a third stage, the specimen were submitted to: as-cast microstructure analysis via optical and scanning electron microscopy (OM and SEM), x-ray dispersive system (EDS) chemical analysis via SEM, Vickers hardness tests for mechanical evaluation and corrosion resistence tests in a 0.9% NaCl solution to simulate exposition to human saliva monitored by open circuit potential and polarization curves. From the obtained results, it was possible to infer that specimens A1 (94,07 wt% Ti and 5,93% wt% Zr), A4 (77,81 wt % Ti and 22,19 wt % Zr) and A8 (27,83 wt% Ti and 72,17 wt% Zr), presented best performance regarding to corrosion resistance, homogeneity and hardness which are necessary issues for biomaterials to be applied as orthopedic and odontological prosthesis / Este trabalho teve como finalidade estudar uma s?rie de onze ligas met?licas bin?rias, tit?nio zirc?nio, quanto ? capacidade de resistirem ?s deteriora??es sem sofrerem modifica??es de suas propriedades iniciais de massa e superf?cie quando expostas a meios agressivos, como condi??o fundamental para que as mesmas sejam aplicadas como biomateriais. A primeira etapa tratou da confec??o das amostras das ligas em forma de pastilhas, empregando-se o processo de fundi??o Plasma Skull realizado na m?quina Discovery Plasma, produzida no Brasil pela EDG Equipamentos. Na segunda etapa, as amostras confeccionadas foram submetidas aos ensaios para a determina??o da composi??o qu?mica resultante de cada liga da s?rie ap?s a fus?o. E durante a terceira etapa foram feitos os procedimentos de avalia??es das amostras quanto ? homogeneidade e apresenta??o da microestrutura de cada uma das ligas no estado bruto de fus?o, como resultados dos ensaios metalogr?ficos por microscopia ?ptica e microscopia eletr?nica de varredura acoplada a espectroscopia por energia dispersiva de raios-x; quanto ? propriedade mec?nica de dureza medida em escala Vickers (HV); e quanto ?s propriedades qu?micas de resist?ncia ? corros?o, quando expostas em solu??o de cloreto de s?dio 0,9 %, para simular a saliva, empregando-se o monitoramento do potencial de circuito aberto e as curvas de polariza??o. A partir dos resultados obtidos foi poss?vel identificar as pastilhas de composi??es qu?micas A1 (94,07% de Ti e 5,93% de Zr), A4 (77,81% de Ti e 22,19% de Zr) e A8 (27,83% de Ti e 72,17% de Zr) que resultaram como maiores detentoras do conjunto de propriedades de resist?ncia ? corros?o, homogeneidade e dureza, as quais s?o mais necess?rias em biomateriais tipo pr?teses ortop?dicas ou odontol?gicas

Page generated in 0.0559 seconds