• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1151
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1192
  • 1192
  • 830
  • 756
  • 358
  • 352
  • 341
  • 310
  • 298
  • 231
  • 199
  • 154
  • 152
  • 143
  • 136
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação volumétrica de sólidos complexos gerados por diferentes protocolos de modelagem computacional

Souza, Leonardo Francisco Provedel de January 2017 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-11-06T14:08:25Z No. of bitstreams: 1 TESE FINAL leonardo Provedel.pdf: 892721 bytes, checksum: 469d11fe33aff9d314e85d27afd4fd8f (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-11-17T14:40:29Z (GMT) No. of bitstreams: 1 TESE FINAL leonardo Provedel.pdf: 892721 bytes, checksum: 469d11fe33aff9d314e85d27afd4fd8f (MD5) / Made available in DSpace on 2017-11-17T14:40:29Z (GMT). No. of bitstreams: 1 TESE FINAL leonardo Provedel.pdf: 892721 bytes, checksum: 469d11fe33aff9d314e85d27afd4fd8f (MD5) / CAPES / Modelagem computacional refere-se ao conjunto de processos eletrônicos que culminam na obtenção de um modelo tridimensional, incluindo a segmentação das imagens e tratamento superficial dos sólidos gerados. Apesar de tais técnicas tornarem-se cada vez mais frequentes no campo da saúde, poucos são os estudos que se propõem investigar a fidelidade destes modelos. O objetivo deste estudo foi comparar o volume de sólidos complexos obtidos por diferentes equipamentos de engenharia reversa e modelagem computacional. Para isto, oito mandíbulas secas foram escaneadas por diferentes equipamentos de tomografia computadorizada (TC) e por um scanner tridimensional, a partir dos quais foram gerados modelos tridimensionais. Esses modelos receberam diferentes processos de tratamento superficial e o volume final dos modelos foi comparado. Os resultados mostraram não haver diferença significante entre o volume dos sólidos com diferentes tratamentos superficiais (p> 0,05) assim como em relação aos diferentes equipamentos de TC (p> 0,05). Comparando-se os equipamentos de TC com o scanner tridimensional, existiram diferenças volumétricas entre os sólidos, a depender do padrão-ouro adotado, principalmente quando as duas ferramentas de tratamento superficial foram utilizadas. Pode-se concluir que o escaneamento tridimensional determinou a geração de sólidos dimensionalmente diferentes das demais técnicas de engenharia reversa, na maioria dos casos, sobretudo quando mais de uma ferramenta de tratamento superficial foi empregada / Computational modeling refers to the set of electronic processes that culminate in obtaining a three-dimensional model, including the segmentation of images and surface treatment of the generated solids. Although such techniques become increasingly frequent in the field of health, few studies are proposed to investigate the fidelity of these models. The objective of this study was to compare the volume of complex solids obtained by different reverse engineering devices and computational modeling. For this, eight dry mandibles were scanned by different CT devices and by a three-dimensional scanner, from which three-dimensional models were generated. These models received different surface treatment processes and the final volume of the models was compared. The results showed no significant difference between the volume of solids with different surface treatments (p> 0.05) as well as with the different CT devices (p> 0.05). Comparing the CT devices with the three-dimensional scanner, there were volumetric differences between the solids, depending on the gold standard adopted, especially when the two surface treatment combined tools were used. It can be concluded that three-dimensional scanning determined the generation of solids dimensionally different from other reverse engineering techniques, in most cases, especially when more than one surface treatment tool was used.
22

Identificação do canal mandibular a partir de diferentes protocolos de tomografia computadorizada de feixe cônico

Simões, Cinthia Coelho January 2011 (has links)
Submitted by Barroso Patrícia (barroso.p2010@gmail.com) on 2013-03-08T18:39:18Z No. of bitstreams: 1 Tese Cinthia.pdf: 1023108 bytes, checksum: 936e1c1ae772dccb262cb7ccc5c2d56e (MD5) / Made available in DSpace on 2013-03-08T18:39:18Z (GMT). No. of bitstreams: 1 Tese Cinthia.pdf: 1023108 bytes, checksum: 936e1c1ae772dccb262cb7ccc5c2d56e (MD5) Previous issue date: 2011 / Este estudo avaliou, objetiva e subjetivamente, a acurácia de diferentes protocolos de tomografia computadorizada de feixe cônico (TCFC) em identificar o canal mandibular humano. Com esse propósito, foram obtidas imagens de TCFC de dez hemimaníbulas maceradas no equipamento K9000 3D, sendo modificada apenas a mA (Grupo I: 2mA; Grupo II: 8mA e Grupo III: 15mA). Todas as aquisições foram feitas com 80kV, FOV de 5 x 3,7cm, matriz de 512 x 512 e voxel de 0,076mm de espessura. Após as aquisições, dois avaliadores analisaram as reconstruções ortogonais em três tamanhos de voxel, constituindo-se, assim, nove grupos experimentais (IA: 2mA e voxel de 0,076mm; IB: 2mA e voxel de 0,535mm; IC: 2mA e voxel de 2,1mm; IIA: 8mA e voxel de 0,076mm; IIB: 8mA e oxel de 0,535mm; IIC: 8mA e voxel de 2,1mm; IIIA: 15mA e voxel de 0,076mm; IIIB: 15mA e voxel de 0,535mm; IIIC: 15mA e voxel de 2,1mm). Para a fase objetiva, foram realizadas mensurações lineares verticais e horizontais nas imagens, por dois examinadores, que foram comparadas com as mensurações realizadas nas mandíbulas secas (padrão-ouro) por um terceiro examinador, sendo calculado o erro de mensuração. Na fase subjetiva, as imagens foram avaliadas por dois examinadores, que atribuíram escores de 0 a 3 para itens relacionados a visualização do rebordo ósseo, corticais do canal mandibular, visualização do canal mandibular e qualidade geral da imagem, além de atribuírem escores nominais (sim ou não) para a aceitabilidade das imagens para mensurações verticais e horizontais. Os resultados demonstraram que as medidas de altura e espessura óssea não apresentaram diferença estatisticamente significativa para todos os grupos experimentais, quando comparadas ao padrão-ouro. Os grupos experimentais estudados apresentaram qualidade de imagem aceitáveis para o planejamento de implantes, com exceção das imagens adquiridas com 2mA e analisadas com voxel de 0,076mm e 0,535mm. Apesar da aceitação de 77,71% das imagens de TCFC para planejamento de implante osteointegrado, todas as medidas de altura e espessura ósseas, realizadas nas imagens dos diferentes grupos experimentais, não diferiram das medidas reais, concluindo-se que todas as imagens possuem qualidade suficiente para identificação do canal mandibular. Entretanto, o protocolo IIC (8mA e voxel de 2,1mm) deve ser,preferencialmente, indicado na identificação do canal mandibular, já que a dose de radiação é menor que os protocolos de 15mA e a qualidade de imagem é superior aos protocolos de 2 mA, além disso, voxel de 2,1mm apresentou maior aceitabilidade das imagens. / Universidade Federal da Bahia, Instituto de Ciências da Saúde
23

Comparação da bioimpedância com a tomografia computadorizada e antropometria na avaliação da composição corporal de adultos e idosos

Eickemberg, Michaela 28 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-23T19:00:02Z No. of bitstreams: 1 Dissertação_Nut_ Michaela Eickemberg.pdf: 1963704 bytes, checksum: 453c418946e3c1fb166471a536c49f7b (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-28T16:33:57Z (GMT) No. of bitstreams: 1 Dissertação_Nut_ Michaela Eickemberg.pdf: 1963704 bytes, checksum: 453c418946e3c1fb166471a536c49f7b (MD5) / Made available in DSpace on 2013-05-28T16:33:57Z (GMT). No. of bitstreams: 1 Dissertação_Nut_ Michaela Eickemberg.pdf: 1963704 bytes, checksum: 453c418946e3c1fb166471a536c49f7b (MD5) / Considerando a importância de métodos simples, práticos, de baixo custo e que apresentam boa acurácia e precisão na estimativa da composição corporal, esta dissertação tem como objetivo avaliar a estimativa da gordura visceral (GV) por meio da bioimpedância (BIA) e a concordância entre a BIA e antropometria na estimativa de gordura corporal total (GCT) e massa corporal magra (MCM) em adultos e idosos. Metodologia: Trata-se de um estudo transversal onde participaram para o primeiro artigo 191 indivíduos (52% mulheres e 49% idosos) e para o segundo 196 (49% homens e 51% adultos). Para o primeiro objetivo obtiveram-se dados sobre tomografia computadorizada (TC) (gordura abdominal total (GAT) e gordura visceral (GV)) e BIA (GCT). Para o segundo, coletaram-se dados antropométricos (índice de massa corporal, somatório das quatro pregas e circunferência muscular do braço (CMB)) e sobre a BIA (percentual de GCT e MCM). Para as análises estatísticas utilizaram-se os seguintes testes: Análise descritiva, Coeficiente de Correlação de Pearson, Curva ROC, Anova, Qui quadrado de Pearson, Kappa e Bland-Altman. Resultados: Para o primeiro objetivo, as áreas de GV ≥130cm2 foram mais observadas em idosos e em homens. A correlação entre o percentual de GCT determinado pela BIA e a área de GV pela TC foi inferior à observada entre o percentual de GCT pela BIA e a área de GAT estimada pela TC. A curva ROC indicou os seguintes percentuais de GCT da BIA que identificaram área de GV de risco: 21,5% para homens adultos, 24,25% para homens idosos; 35,05% para mulheres adultas, 38,45% para mulheres idosas, com sensibilidade de 78,6%, 82,1%, 83,3%, 66,7% e especificidade de 70,6%, 62,5%, 79,1%, 69%, respectivamente. Para o segundo objetivo, as correlações entre os dois métodos foram estatisticamente significantes, exceto para GCT em homens idosos e MCM em idosas. A análise de concordância dos métodos pelo coeficiente Kappa mostrou uma concordância considerável entre os métodos somente para GCT em mulheres adultas e idosas. Para os dois modelos de análise de concordância Kappa e Bland-Altman, a BIA e antropometria não concordaram na estimativa de GCT e MCM. Conclusões: A BIA apresentou boa sensibilidade e especificidade para predizer GV, entretanto, outros aparelhos e técnicas devem ser investigados com o intuito de melhorar esta predição. A antropometria e a BIA não concordam na determinação de gordura e massa corporal magra em adultos e idosos. Novas investigações devem ser realizadas, explorando, especialmente, métodos simples como as pregas cutâneas e a CMB, e que comparem estas técnicas com parâmetros de referência para estimar a composição corporal. / Salvador
24

Tomografia computadorizada de alta resolução no estudo das alteraçõess torácicas na fibrose cística

Kauer, Carmen Lucia January 1995 (has links)
O trabalho avalia a contribuição da tomografia computadorizada de alta resolução (TCAR) para o estudo das alterações torácicas na fibrose cística, através da comparação com o exame radiologico convencional do tórax (ERCT). Determina os achados patológicos de 25 pacientes (com 5 a 17 anos) na TCAR e os compara com os identificados no ERCT. Os exames foram realizados em sucessão imediata. Utilizaram-se cortes axiais de 2 mm de espessura, com ]Omm de intervalo entre eles; tempo de rastreamento de 1,4 e 2,0 s; 125 kV e 150 mA. As TCAR foram fotografadas em 3 janelas de densidades apropriadas ao estudo do tórax: parênquima (nível-l024 e janela de 1200 a 2050), brônquios (nível- 550 a - 1000 e janela 1700 a 2300) e mediastino (nível - 30 a -80 e janela 320 a 500). Os achados mais freqüentemente detectados na TCAR do que no ERCT são: espessamento brônquico (100 %), bronquiectasias cilíndricas (96 %), adenomegalias (92 %), impacção mucóide (84 0/0), consolidação e/ou atelectasia (48 %), espessamento pleural costal (32 %), bolhas (20 %) e enfisema localizado (8 %). Bronquiectasias císticas (52 %) e deformação e/ou espessamento das cissuras (60 %) foram mais freqüentes no ERCT. A identificação de alterações das VIas aéreas nos segmentos broncopulmonares foi significativamente superior na TCAR (p<0,05). Em ambos exames, os lobos à direita foram mais freqüentemente comprometidos, especialmente o superior. Verificou-se, em 16 % das TCAR, espessamento do tecido intersticial ao longo dos feixes broncovasculares dos segmentos basais de ambos os pulmões, incluil1do vasos venosos e a gordura presente entre estas diferentes estruturas. A aplicação de sistema de escores para os achados da TCAR permite avaliação mais objetiva da extensão e intensidade das alterações detectadas, diminuindo o componente subjetivo da interpretação radiológica. A TCAR contribui para o entendimento da natureza de alguns achados do ERCT. / This study evaluate the contribution of high resolution computed tomography (HRCT) in assessing thoracic involvement in cystic fibrosis, as compared to chest plain radiography (CPR). The HRCT findings of 25 patients (5 to 17 years old) were determined and compared with those obtained by CPR. The two investigations were performed in elose succession. Sections 2 mm thick were obtained at 10 mm intervals with IA to 2.0 s acquisition time at 125 kV and 150 mA. AlI images were photographed at three leveIs and windows settings appropriated for evaluation of the thorax: parenchyma (widths 1200 to 2050 at leveI -1024), bronchi (widths 1700 to 2300 at leveI -550 to -] 000) and mediastinum (widths 320 to 500 at leveI -30 to -80). The findings more frequently detected by HRCT than by CPR were: peribronchial thickening (100 %), cylindrical bronchiectasis (96 %), adenomegaly (92 %), mucus plugging (84 %), consolidationlatelectasis (48 %), costal pleural thickening (32 %), bullae (20 %) and local emphysema (8 %). Cystic bronchiectasis (52 0/0) and fissures deformationlthickening (60%) were more frequent1y detected by CPR. Detection of airways abnormalities in the bronchopulmonary segments was significant1y superior by HRCT (p<0,05). By either exam the right lobes were more frequently involved, specially the upper lobe. Thickening of the intersticial tissue along the bronchovascular bundles in bilateral basilar segments, ineluding venous vessels and the fat present between these different structures, were manifested in ]6 % of the HRCT exams. The use of a scoring system to HRCT findings allows a more objetive evaluation of the extent and severity of the abnormalities detected and diminish the subjective component of radiographic interpretation. HRCT did contribute to the understanding ofthe pathologic nature of some CPR findings.
25

Análise morfológica das estruturas anatômicas da região anterior de maxila e suas variações avaliadas por meio de imagens tomográficas de feixe cônico

Velho, Fernando Mathias Teixeira January 2016 (has links)
Introdução: A reconstrução e avaliação tridimensional das estruturas ósseas do crânio por meio da Tomografia Computadorizada de Feixe Cônico (TCFC) abriu a possibilidade para uma melhor investigação dos acidentes anatômicos presentes na região de interesse do cirurgião-dentista. A TCFC representa o padrão-ouro no quesito qualidade e fidelidade de seus cortes, possibilitando maior clareza na detecção das alterações morfológicas de tecidos duros e elementos dentários observadas em imagens tomográficas. Objetivo: Investigar as variações anatômicas e morfológicas encontradas nas fossas nasais, canal nasopalatino (com medições de comprimento, espessura e dos diâmetros do forame incisivo e foramina de Stenson), canalis sinuosus e foraminas acessórias por meio de exames tomográficos de feixe cônico relacionando com gênero, idade e presença ou ausência dentária na região anterior da maxila. Material e Métodos: Após a aplicação dos critérios de exclusão, as estruturas acima foram analisadas em 1.143 exames de TCFC, de 628 mulheres e 515 homens, por três examinadores treinados e calibrados, especialistas em Radiologia Odontológica e Imaginologia. Os dados finais foram avaliados de forma descritiva com a utilização de porcentagem e frequência dos achados em relação à amostra. A correlação dos dados foi realizada através do Test t, ANOVA, Kruskal-Wallis, Tukey, Testes Qui-Quadrados exatos de Fisher e de Pearson isolando as variáveis de gênero, idade e presença ou ausência dentária (significância de 0,5%). / Introduction: The reconstruction and tridimensional evaluation of bone skull structures through Cone Beam Computed Tomography (TCFC) opened the possibility for a better inquiry of the anatomic accidents present in the interest region of the dentist-surgeon. The TCFC represent the gold-pattern in the quality question and fidelity of its cuts, enabling greater clarity on morphological alterations detection observed in tomographic images. Objective: Investigate the anatomic variations found in nasal fossae, nasopalatine canal (with measures of length, thickness and diameter of the incisor foramen and Stenson's foramina), canalis sinuosus and acessory foramina by means of CBCT, relating with gender, age and presence or absence of teeth in the anterior region of the maxila. Material and methods: After applying the exclusion criteria, the above strcutures were analysed in 1.143 TCFC exams, of 628 female and 515 male, by three trained and calibrated examiners, specialized in Dental Radiology. The final data were evaluated in descriptive way using percentage and frequency of the findings related to the sample. The correlation of the data was carried out using t test , ANOVA, Kruskal-Wallis, Tukey, and Fisher's and Pearson's exact Chi-Square tests, isolating the variables of gender, age and dental presence or absence (0.5% significance).
26

Avaliação do erro das coordenadas de localização estereotáctica guiada por tomografia computadorizada do encéfalo

Moreno, paulo January 1998 (has links)
São analisados 106 pacientes submetidos a localização estereotáctica. Os procedimentos variaram de biópsias cerebrais, orientação de craniotomias, colocação de cateter em cavidade tumoral, drenagem de hematoma intracerebral e drenagem de abscesso cerebral. As orientações de craniotomias foram para MAVs, tumores e processos inflamatórios, em 21 pacientes. As biópsias cerebrais estereotácticas para diagnóstico anatomopatológico apresentaram um índice de positividade de 87,50 % com complicações em 1,20 %, em 82 casos. São analisadas estatisticamente as variáveis como: idade, sexo, procedimento realizado, diagnóstico anatomopatológico e volume das lesões. É discutida a imprecisão na aquisição e cálculo das coordenadas estereotácticas com a TC do encéfalo e verificada a precisão do método estereotomográfico com a utilização de um phanton. O maior erro das coordenadas foi de 6,8 mm. / It is discussed 106 patients submited to estereotactic procedures. The procedures were cerebral biopsies, orientation of craniotomies, insertion of a catheter in one tumor cavity, aspiration of one spontaneos haematoma and aspiration of one brain abscess. The guided craniotomies were for AVMs, tumors and inflamatory disease in 21 patients. The positivity of biopsies was 87,50 % and the morbidity and mortality was 1,20 %. Statistical analisys was performed: sex, age, kind of procedure performed, the positivity of the anatomopathologic exam and the volume of the brain lesions. It is discussed the error in the aquisition and calculations of the estereotactic coordinates with the CAT scan and the error with this method with a phanton. The greatest error in the coordinates was 6,8 mm.
27

Acurácia diagnóstica das imagens tomográficas de feixe cônico, com diferentes voxels, na avaliação da cobertura óssea

Oliveira, Luciana Koser 04 December 2014 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2015-07-17T19:42:18Z No. of bitstreams: 1 OLIVEIRA, Luciana Koser.pdf: 2962253 bytes, checksum: 4fe6292b5bc0b9a60eeb5545680814a7 (MD5) / Made available in DSpace on 2015-07-17T19:42:18Z (GMT). No. of bitstreams: 1 OLIVEIRA, Luciana Koser.pdf: 2962253 bytes, checksum: 4fe6292b5bc0b9a60eeb5545680814a7 (MD5) / CNPQ / Uma correta avaliação da condição óssea é essencial para o diagnóstico, prognóstico e estratégias de tratamento do suporte ósseo periodontal. As informações advindas do exame clínico, associadas ao diagnóstico por imagem, servem de guia para uma avaliação apurada sobre o osso alveolar e a possível presença de defeitos ósseos. A tomografia computadorizada de feixe cônico (TCFC) ainda é subutilizada em diagnóstico periodontal, além de pouco pesquisada. Objetivo: Assim, o presente estudo foi desenvolvido com o intuito de estabelecer a acurácia diagnóstica da TCFC na avaliação da cobertura óssea, utilizando diferentes voxels. Material e Métodos: Nos maxilares de cinco crânios secos, com dentição completa, foram identificados 63 defeitos ósseos nos 180 terços dentários de doze dentes anteriores, analisados com o auxílio de um paquímetro digital. Para a aquisição das imagens foi utilizado o aparelho CS 9000 3D Extraoral Dental Cone Beam Imaging System (Carestream Dental, Rochester, USA), com 60 kVp, 8 mA(maxila)/ 6,3 mA(mandíbula) e, primeiramente, a utilização do voxel de 0,2mm, seguido, num segundo momento, da utilização do voxel de 0,076mm. Posteriormente, as imagens adquiridas e reconstruídas nos planos axial e parassagital foram avaliadas por 2 examinadores experientes, de acordo com um protocolo específico, referindo presença ou ausência de cobertura óssea (CO). Todos os dados foram tabulados e analisados pelos testes McNemar e Kappa, adotando o valor de p ≤ 0,05. Resultados: Na avaliação das reconstruções axiais e parassagitais juntas, com voxel 0,2, 95,24% dos sítios com ausência de CO, foram diagnosticados através de imagens por TCFC pelos dois avaliadores, cuja concordância se mostrou substancial (parassagitais, K=0,652; axiais, K=0,756). Na avaliação das reconstruções com voxel 0,076, 93,89% dos sítios com ausência de CO foram diagnosticados e a concordância dos avaliadores se mostrou quase perfeita (parassagitais, K=0,875; axiais, K=0,889). Conclusão: A TCFC apresenta elevada sensibilidade, especificidade e acurácia no diagnóstico da CO, quer em reconstruções parassagitais, quer em reconstruções axiais. As reconstruções parassagitais apresentaram melhor especificidade e acurácia no diagnóstico da CO nos dentes anteriores, quando comparadas com as reconstruções axiais, que por sua vez apresentaram uma sensibilidade superior à das imagens parassagitais, em ambos os voxels analisados. Portanto, é necessária e vantajosa a avaliação dinâmica multiplanar das imagens para confirmar o diagnóstico da cobertura óssea com consequente auxílio nas estratégias de tratamento. Ao comparar os dois voxels avaliados (0,2 e 0,076), os resultados se equivaleram, o que significa que nem sempre haverá ganho de diagnóstico, reduzindo-se, progressivamente, o tamanho do voxel. / A correct assessment of bone condition is crucial for the diagnosis, prognosis and treatment strategies of periodontal bone support. The information resulting from clinical examination, associated with image diagnostic, serve as a guide for an accurate assessment of the alveolar bone and the possible presence of bone defects. The cone beam computed tomography (CBCT) is still underutilized in periodontal diagnosis, besides little researched. Purpose: The aim of the present study was to establish the diagnostic accuracy of the CBCT in the evaluation of bone cover, using different voxels. Material and Methods: In the jaws of five dried skulls, with complete dentition, were identified 63 bone defects in 180 thirds of twelve anterior teeth, analyzed with a digital caliper rule. For the acquisition of the images was used the CS 9000 3D Extraoral Dental Cone Beam Imaging System (Carestream Dental, Rochester, USA), with 60 kVp, 8 mA(maxillae)/ 6.3 mA(jaw) and primarily, the use of voxel of 0.2mm, followed by a second time, with the use of voxel of 0.076mm. Later, the images acquired and reconstructed in axial and parasagittal planes were evaluated by 2 experienced examiners, according to a specific protocol, indicating presence or absence of bone cover. All data were tabulated and analyzed by McNemar and Kappa tests, adopting the value of p≤0,05. Results: In the evaluation of axial and parassagital reconstructions together, with voxel 0.2, 95.24% of the sites with absence of bone cover were diagnosed through images by CBTC, by two assessors, whose agreement was substantial (parassagital reconstructions, K=0.652; axial, K=0.756). In the evaluation of the 0,076 voxel reconstructions, 93,89% of sites with absence of bone cover were diagnosed and the assessors’s agreement was almost perfect (parassagital reconstructions, K=0,875; axial, K=0,889). Conclusion: CBTC offers high sensitivity, specificity and accuracy in diagnosis of bone cover and either in parassagital reconstructions, or in axial reconstructions. The parassagital reconstruction images showed better specificity and accuracy in bone cover diagnosis of anterior teeth than the axial reconstruction ones, which in turn had a higher sensitivity than the parassagital reconstruction images, in both voxels analyzed. Therefore, it is necessary and advantageous a dynamic multiplanar image evaluation to confirm bone cover diagnosis, in order to help treatment strategies. Comparing the voxels evaluated (0.2, 0.076), the results were equivalent, which means that not always there will be gain of diagnosis, reducing progressively the size of the voxel.
28

Avaliação das variações anatômicas do canal mandibular em tomografia computadorizada

Pinto, Regina Lucia Seixas January 2018 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2018-09-05T13:12:32Z No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / Approved for entry into archive by Edvaldo Souza (edvaldosouza@ufba.br) on 2018-09-12T21:08:32Z (GMT) No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / Made available in DSpace on 2018-09-12T21:08:32Z (GMT). No. of bitstreams: 1 TESE Fiinal REGINA.pdf: 1968324 bytes, checksum: 42efa0f0ccbcfdcae94a952140abbdda (MD5) / O uso das técnicas para obtenção de imagens tridimensionais, como os exames de tomografia computadorizada (TC), tem contribuído significativamente para a visualização das condições de normalidade e alterações das estruturas do complexo dentomaxilofacial, minimizando riscos potenciais diante de procedimentos cirúrgicos que possam envolver a integridade dessas estruturas. Este estudo teve como objetivo avaliar a presença de variações anatômicas do canal mandibular, as quais foram relacionadas ao sexo e lado afetado do indivíduo. A amostra foi constituída por 302 exames de TC multidetectores de mandíbula, de alta resolução, com janela óssea. Foram obtidas reconstruções panorâmicas e transversais da mandíbula, a partir dos cortes axiais obtidos, que foram avaliados duas vezes por um único observador. Os resultados mostraram que 85 (28,1%) TC eram de homens e 217 (71,9%) de mulheres. Do total de exames, 209 (69,2%) apresentaram trajeto único, sendo 44 (14,9%) CMd únicos, bilaterais e altos; 66 (21,9%) CMd únicos, bilaterais e intermediários, e 98 (32,5%) CMd únicos, bilaterais e baixos. As demais TC (93 exames – 30,8%) apresentaram outras variações, sendo 66 (21,9%) com ramificações do CMd, com o tipo 1 de duplicação o padrão mais frequente, e 27 (8,9%) com ausência de simetria. A presença de forames mentual e mandibular acessórios e loop anterior foi pequena; em contrapartida, houve uma grande prevalência de canais na região anterior da mandíbula. Já o canal incisivo mostrou-se presente em 238 (78,8%) TC, mais frequente no sexo feminino. Não foram encontradas associações significantes entre as variações encontradas e o sexo do indivíduo (p> 0,05). / The use of techniques to obtain three-dimensional images, such as computed tomography (CT) scans, has significantly contributed to the visualization of normal conditions and alterations of structures from the dentomaxillofacial complex, minimizing potential risks from surgical procedures that may involve integrity structures. This study aimed to evaluate the presence of anatomical variations of the mandibular canal, which were related to the sex and affected side. The sample consisted of 302 high resolution multidetector mandible CT scans with a bone window. Panoramic and transverse reconstructions of the mandible were obtained from the axial sections, which were evaluated twice by a single observer. The results showed that, 85 (28.1%) CT were men and 217 (71.9%) were women; of the total number of exams, 209 (69.2%) had a single course, of which 45 (14.9%) were bilateral single high MC; 66 (21.9%) bilateral single intermediate MC and 98 (32.5%) bilateral single low MC. The others CT (93 – 30.8%) CT had other variations, 66 (21.9%) were branches of MC and type 1 was the most frequent duplication pattern, and 27 (8.9%) lack of symmetry. As for the presence of accessory mental and mandibular foramina, and anterior loop was small; in contrast there was a high prevalence of canals in the anterior region of the mandible. The mandibular incisive canal was present in 238 (78.8%) CT, more frequent in females. No significant associations were observed between the variations found and the gender of the individual (p> 0.05).
29

Melhoria do desempenho metrológico da tomografia computadorizada por raixos X por meio da seleção sistemática dos parâmetros de configuração

Nardelli, Vitor Camargo January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2013-06-25T23:21:45Z (GMT). No. of bitstreams: 1 310201.pdf: 24900586 bytes, checksum: 0d8653a287d04bb1e9c86e79e56d699a (MD5) / A aplicação industrial da tomografia computadorizada (CT) vem crescendo rapidamente na caracterização da geometria de peças. Durante o processo de medição, o usuário deve tomar decisões com relação a parâmetros que influenciam diretamente a qualidade da imagem e, consequentemente, o resultado da medição. Porém, as complexidades inerentes ao processo de medição por CT fazem com que boa parte dos usuários tenham dificuldades para relacionar os valores dos parâmetros de configuração com a qualidade dos dados gerados pela medição. Isso leva normalmente a um processo iterativo de escolha, que afeta negativamente o tempo de setup. Diante deste contexto, o propósito de pesquisa foi demonstrar que é possível sistematizar o processo de seleção dos parâmetros de configuração de forma a obter resultados adequados em termos da incerteza e o tempo de medição, sem necessidade de iteração. Desta forma, usuários com menos conhecimento, tempo e experiência também poderão ser capazes de obter resultados robustos para medições com CT. Como a definição de um critério de qualidade é um aspecto fundamental para a comparabilidade dos resultados, uma importante contribuição deste trabalho é a avaliação da qualidade dos dados gerados por CT através da análise da dispersão dos pontos extraídos de uma determinada característica de referência de uma peça ou padrão. A utilização deste indicador de dispersão em uma abordagem experimental sistêmica resultou na estruturação de um conjunto de regras e recomendações para apoiar o processo de seleção dos parâmetros de configuração. O método para seleção sistemática dos parâmetros de configuração apresentado neste trabalho irá contribuir na orientação de usuários de CT, auxiliar fabricantes na otimização de hardwares e softwares de seus sistemas e auxiliar os metrologistas na identificação e redução das causas de erro das medições. / The application of industrial computed tomography (CT) for the geometrical characterization of work pieces within the scope of quality assurance processes is growing rapidly. When planning the execution of a specific measurement task, the user has to make decisions about the values of parameters that directly influence the image quality and therefore the measurement result. Due to the large number of parameters, the planning and setup processes can be very time consuming. The complex relationships between this parameters and the measurement result makes the planning process strongly dependent on the experience of the user, leading frequently to a trial-and-error setup approach. Based on this context, the purpose of this research is to demonstrate that the process for defining the setup parameters can be sistemized in order to obtain better results in terms of measurement uncertainty and measurement time, without the need of a iterative approach. Therefore, users with less knowledge, time and experience would also be able to get robust measurements from CT systems. Since the definition of a quality index is an essencial requirement for the comparability of the results, an important contribution of this thesis is to assess the quality of the CT extracted data by the analysis of extracted integral features. A systematic experimental approach combined the proposed quality index resulted in the structuring a set of rules and recommendations to assist users on the selection of the setup parameters. The information provided by the systematic approach for selection of setup parameters is complementary to a framework project aiming in developing support systems to help CT users in selecting adequate setup parameters; assisting manufactures on the optimization of their CT systems; and assisting researchers on quantifying sources of measurement errors.
30

Desenvolvimento e validação de novas peças-padrão para tomografia computadorizada industrial

Santos, Rafael Pacheco dos January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2012 / Made available in DSpace on 2013-12-05T22:16:11Z (GMT). No. of bitstreams: 1 317589.pdf: 37414152 bytes, checksum: 0973f5f946c7598685f365423aa96da2 (MD5) Previous issue date: 2012 / A tomografia computadorizada por raios X (TC) é uma emergente tecnologia de medição por coordenadas. Devido ao seu princípio físico que utiliza a atenuação de raios X, a TC permite um controle simultâneo das características geométricas e do material, sendo adequada para a medição de peças de alta complexidade geométrica, de baixa rigidez e de baixa densidade. Durante o processo de preparação de medição (setup) as decisões tomadas pelo usuário têm grande influência sobre a qualidade final da medição. Trata-se de uma etapa demorada e fortemente dependente da experiência do usuário, o que leva geralmente a soluções iterativas baseadas em prova e erro. A geração e sistematização do conhecimento sobre as relações entre a tarefa de medição, parâmetros de configuração e a matriz de voxel resultante pode ser considerado um importante passo para a consolidação da TC no âmbito da metrologia dimensional. Uma iniciativa nesse sentido é desenvolvida no escopo do programa BRAGECRIM. O projeto CT Metro prevê a melhoria do processo de setup através do desenvolvimento de um sistema que objetiva orientar o operador na escolha dos parâmetros de medição. Dentro desse escopo, o presente trabalho teve como objetivo o desenvolvimento e validação experimental de um conjunto de peças que emulem aspectos específicos das tarefas de medição desempenhadas por tomógrafos industriais e que representem a sua grande diversidade. Tais peças foram desenvolvidas com uma abordagem sistemática levando em consideração aspectos específicos da tecnologia. Por fim, um conjunto de medições permitiu a validação das peças e um ganho significativo no entendimento sobre a relação entre parâmetros de configuração e qualidade do processo de medição.<br> / Abstract : The industrial computed tomography (CT) is an emerging technology of coordinate measuring. Due to its physical principle that uses the attenuation of X-ray, CT allows concurrent control of the geometric and materialcharacteristics. It is suitable for measuring the geometric pieces of high complexity, low stiffness and low density. During the preparation process the definition of setup parameters are very important over measurement quality, however is slow and strongly dependent on the user experience which usually leads to iterative solutions. The generation and systematization of knowledge about the relationship among the measurement task, setup parameters and the resulting voxel matrix can be considered an important step towards the consolidation of CT in the context of dimensional metrology. One initiativein this way is developed within the scope of the project CTmetro. This project has the object to design software which will help the user on definition of setup parameters.Within this framework the present work had as objective the development and experimental validation of a set of pieces that emulate specific aspects of measurement tasks performed by industrial CT scanners and representing its great diversity. These pieces were developed with a systematic approach that used the best practices of precision engineering taking into account the specific aspects of technology. Taking care about the manufacturing process that enabled the calibration with low uncertainty values. Finally, the set of measurements allow the validation of parts as well as a significant gain in understanding the relationship between setup parameters and quality of the measurement process.

Page generated in 0.0937 seconds