Transdutores de RF para experimento de imagens em pequenos animais / RF coils for MRI experiments on small animals

Papoti, Daniel 27 April 2006 (has links)
O objetivo deste projeto é o desenvolvimento de transdutores de RF tipo gaiola (birdcage coil) e sela (saddle coil), com desenho especial inovador, que mantém elementos com comprimento elétrico constante, para um campo magnético de 2 Tesla. Este transdutor deve permitir o estudo e também o desenvolvimento de novas metodologias em imagens e espectroscopia por RMN de pequenos primatas como marmosets, exigidos pela interação deste grupo com o programa CInAPCe (Cooperação Interinstitucional de Apoio a Pesquisas sobre o Cérebro). Essas bobinas também se destinam ao uso em metodologias de imagens e espectroscopia ?in vivo? por Ressonância Magnética Nuclear (RMN), que utilizem pulsos de RF caracterizados como Pulsos Adiabáticos. Outra perspectiva é a continuação do desenvolvimento de bobinas de RF que operam segundo as características de bobinas de superfície, que pode resultar deste trabalho. Os resultados nos mostram que para as dimensões e freqüência utilizadas, a interação entre os condutores que compõe os transdutores é mais relevante do que a perda de fase da corrente elétrica devido às diferenças no comprimento elétrico. O cruzamento entre os condutores consiste num bom desenho alternativo, melhorando a homogeneidade de campo de RF e a relação sinal/ruído. / The purpose of the present work is the development of birdcage- and saddlelike RF transducers which were based on a special and innovative approach. The aim of this design is to keep constant the electromagnetic length of its elements, for a magnetic field intensity of 2 Tesla. These resonators will allow both the study and the development of new imaging and spectroscopy methods addressed to the NMR research on small primates such as marmosets. Such studies are part of the cooperation between this group and other participants of the CInAPCe program, Portuguese acronym for Inter-institutional Cooperation to Support Brain Research. Other perspective is the continuing development of RF coils whose characteristics are similar to surface coils, also designed for anatomic specific studies of imaging and in vivo NMR spectroscopy that take advantage from the use of RF pulses characterized as Adiabatic Pulses. From the results it could be verified that, for the frequency and dimensions used, the interaction between the conductive paths present in the transducers is more significant than the electric current phase losses due to differences in electric path. The crossing of the conductive paths constitute a good alternative design, improving the RF field homogeneity and the signal to noise ratio.
162

Modelagem vibracional de transdutores de ultra-som piezoelétricos pelo método de elementos finitos. / Vibrational modeling of piezoelectric ultrasonic transducers by the finite element method.

Silva, Emilio Carlos Nelli 24 June 1993 (has links)
Apresentam-se as bases teóricas do Método de Elementos Finitos (MEF) piezoelétrico, e a sua aplicação na modelagem de transdutores de ultra-som piezoelétricos, que consiste na determinação das características vibracionais (frequências de ressonância e anti-ressonância, modos de vibrar e coeficiente de acoplamento eletromecânico), obtenção da curva de admitancia, análise transiente da estrutura piezoelétrica sujeita a uma excitação pulsada e análise da influência da variação das constantes piezoelétricas do transdutor com o raio. Utilizando-se o MEF aplicado a acústica obteve-se o campo acústico gerado pelo transdutor operando em onda contínua, bem como iniciou-se o estudo da propagação de ondas num líquido, analisando-se as ondas geradas pela excitação pulsada de um pistão plano em contato com o fluido. Os modos de vibrar e os valores de frequências de ressonância obtidos para um transdutor, foram comparados com os resultados experimentais. / The theoretical basis of piezoelectric finite element method (FEM), and its application in piezoelectric ultrasonic transducer modelling is presented. Among these applications we have the calculation of resonance and antiresonance frequencies, vibration modes, piezoelectric coupling coefficient, admittance curve and transient analysis of piezoelectric structure excited by a short pulse. By means of piezoelectric FEM the influence of variation of piezoelectric constant with radius is analysed. It is discussed three kind of functions (linear, cosinoidal and Gaussian). This technique is called apodization. The acoustic filed generated by the transducer operating in continuous wave (CW) was calculated by using FEM applied to acoustic, considering the fluid-structure coupling. The study of wave propagation in liquids is started by using FEM, analyzing the waves generated by a plane piston in contact with the fluid, excited by a short pulse. For each case discussed above, all boundary conditions and hypothesis assumed in the construction of finite element models are discussed. Although the models considered are circular transducers, the concepts acquired can be expanded to other geometries. The vibrational modes were visualized by means of a laser interferometry technique (ESPI), and the admittance curves were measured by using an impedometer. These results were compared with the FEM results, and the models precision was discussed.
163

Avaliação de transdutores para análise metabólica humana. / Assessment of transducers to human metabolic analysis.

Moriya, Henrique Takachi 08 March 1999 (has links)
A calorimetria indireta para análise do metabolismo humano tem se mostrado um método não invasivo de crescente importância no estudo mais preciso das respostas metabólicas e cardio-respiratórias. Entretanto, o alto custo dos equipamentos aliado à falta de conhecimento das técnicas tem impedido a disseminação do uso de analisadores metabólicos no Brasil. Este trabalho foi desenvolvido com o intuito de oferecer uma visão global dos procedimentos de calorimetria indireta aplicados à avaliação do metabolismo humano sob a abordagem de Engenharia Biomédica. Foram avaliados três transdutores tipicamente utilizados em equipamentos de calorimetria indireta para análise metabólica humana: um transdutor eletroquímico de oxigênio, um transdutor de dióxido de carbono por radiação infravermelha e um transdutor de fluxo em volume tipo turbina. O transdutor de oxigênio mostrou-se bastante confiável, mas com um tempo de resposta bastante elevado para aplicações em análises de respiração a respiração. A principal deficiência do transdutor de dióxido de carbono está no fato de sua configuração proporcionar um aumento significativo na resistência à respiração do indivíduo. Verificou-se que o transdutor de fluxo em volume apresenta um melhor comportamento para um fluxo em torno de 20 litros/minuto. Apesar das limitações apresentadas pelos transdutores, os resultados dos ensaios foram úteis e representativos para a compreensão do funcionamento de um analisador metabólico humano porcalorimetria indireta, evidenciando quais deficiências devem ser sanadas em pesquisas futuras e os cuidados a serem considerados na implantação do laboratório para análise metabólica/respiratória sendo instalado no Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo. / The indirect calorimetry for analysis of the human metabolism has been a no invasive method of increasing importance in the study of metabolic and cardiorespiratory responses. However, the high cost of the equipment ally to the lack of knowledge of the techniques have been obstacles to the use of metabolic analysers in Brazil. This research was developed with the intention to offer a global vision of the applied procedures of indirect calorimetry to the evaluation of the human metabolism under the prism of the Biomedical Engineering. Three transducers typically used in equipment of indirect calorimetry for metabolic analysis had been evaluated: an electrochemical transducer of oxygen, a carbon dioxide transducer by infrared absorption and a turbine flowmeter. The oxygen transducer revealed sufficiently trustworthy, but a too high response time for applications in breath by breath analyses. The main deficiency of the transducer of carbon dioxide is to provide a significant increase in the flow resistance. It was verified that the flowmeter presents one better behavior for a stream around 20 litres/minute. Despite the limitations presented for the transducers, the results of the assays had been useful and representative for the understanding of the functioning of a human metabolic analyser for indirect calorimetry, evidencing which points have to be improved in future researches and to be considered in the implantation of the laboratory for metabolic and respiratory analysis being installed in the Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
164

Modelagem vibracional de transdutores de ultra-som piezoelétricos pelo método de elementos finitos. / Vibrational modeling of piezoelectric ultrasonic transducers by the finite element method.

Emilio Carlos Nelli Silva 24 June 1993 (has links)
Apresentam-se as bases teóricas do Método de Elementos Finitos (MEF) piezoelétrico, e a sua aplicação na modelagem de transdutores de ultra-som piezoelétricos, que consiste na determinação das características vibracionais (frequências de ressonância e anti-ressonância, modos de vibrar e coeficiente de acoplamento eletromecânico), obtenção da curva de admitancia, análise transiente da estrutura piezoelétrica sujeita a uma excitação pulsada e análise da influência da variação das constantes piezoelétricas do transdutor com o raio. Utilizando-se o MEF aplicado a acústica obteve-se o campo acústico gerado pelo transdutor operando em onda contínua, bem como iniciou-se o estudo da propagação de ondas num líquido, analisando-se as ondas geradas pela excitação pulsada de um pistão plano em contato com o fluido. Os modos de vibrar e os valores de frequências de ressonância obtidos para um transdutor, foram comparados com os resultados experimentais. / The theoretical basis of piezoelectric finite element method (FEM), and its application in piezoelectric ultrasonic transducer modelling is presented. Among these applications we have the calculation of resonance and antiresonance frequencies, vibration modes, piezoelectric coupling coefficient, admittance curve and transient analysis of piezoelectric structure excited by a short pulse. By means of piezoelectric FEM the influence of variation of piezoelectric constant with radius is analysed. It is discussed three kind of functions (linear, cosinoidal and Gaussian). This technique is called apodization. The acoustic filed generated by the transducer operating in continuous wave (CW) was calculated by using FEM applied to acoustic, considering the fluid-structure coupling. The study of wave propagation in liquids is started by using FEM, analyzing the waves generated by a plane piston in contact with the fluid, excited by a short pulse. For each case discussed above, all boundary conditions and hypothesis assumed in the construction of finite element models are discussed. Although the models considered are circular transducers, the concepts acquired can be expanded to other geometries. The vibrational modes were visualized by means of a laser interferometry technique (ESPI), and the admittance curves were measured by using an impedometer. These results were compared with the FEM results, and the models precision was discussed.
165

Avaliação de transdutores para análise metabólica humana. / Assessment of transducers to human metabolic analysis.

Henrique Takachi Moriya 08 March 1999 (has links)
A calorimetria indireta para análise do metabolismo humano tem se mostrado um método não invasivo de crescente importância no estudo mais preciso das respostas metabólicas e cardio-respiratórias. Entretanto, o alto custo dos equipamentos aliado à falta de conhecimento das técnicas tem impedido a disseminação do uso de analisadores metabólicos no Brasil. Este trabalho foi desenvolvido com o intuito de oferecer uma visão global dos procedimentos de calorimetria indireta aplicados à avaliação do metabolismo humano sob a abordagem de Engenharia Biomédica. Foram avaliados três transdutores tipicamente utilizados em equipamentos de calorimetria indireta para análise metabólica humana: um transdutor eletroquímico de oxigênio, um transdutor de dióxido de carbono por radiação infravermelha e um transdutor de fluxo em volume tipo turbina. O transdutor de oxigênio mostrou-se bastante confiável, mas com um tempo de resposta bastante elevado para aplicações em análises de respiração a respiração. A principal deficiência do transdutor de dióxido de carbono está no fato de sua configuração proporcionar um aumento significativo na resistência à respiração do indivíduo. Verificou-se que o transdutor de fluxo em volume apresenta um melhor comportamento para um fluxo em torno de 20 litros/minuto. Apesar das limitações apresentadas pelos transdutores, os resultados dos ensaios foram úteis e representativos para a compreensão do funcionamento de um analisador metabólico humano porcalorimetria indireta, evidenciando quais deficiências devem ser sanadas em pesquisas futuras e os cuidados a serem considerados na implantação do laboratório para análise metabólica/respiratória sendo instalado no Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo. / The indirect calorimetry for analysis of the human metabolism has been a no invasive method of increasing importance in the study of metabolic and cardiorespiratory responses. However, the high cost of the equipment ally to the lack of knowledge of the techniques have been obstacles to the use of metabolic analysers in Brazil. This research was developed with the intention to offer a global vision of the applied procedures of indirect calorimetry to the evaluation of the human metabolism under the prism of the Biomedical Engineering. Three transducers typically used in equipment of indirect calorimetry for metabolic analysis had been evaluated: an electrochemical transducer of oxygen, a carbon dioxide transducer by infrared absorption and a turbine flowmeter. The oxygen transducer revealed sufficiently trustworthy, but a too high response time for applications in breath by breath analyses. The main deficiency of the transducer of carbon dioxide is to provide a significant increase in the flow resistance. It was verified that the flowmeter presents one better behavior for a stream around 20 litres/minute. Despite the limitations presented for the transducers, the results of the assays had been useful and representative for the understanding of the functioning of a human metabolic analyser for indirect calorimetry, evidencing which points have to be improved in future researches and to be considered in the implantation of the laboratory for metabolic and respiratory analysis being installed in the Laboratório de Engenharia Biomédica da Escola Politécnica da Universidade de São Paulo.
166

Rede de sensores para engenharia biomédica utilizando o protocolo IEEE1451. / Sensors network for biomedical engineering using IEEE1451 protocol.

Wesley Becari 30 January 2012 (has links)
A utilização de sensores e de atuadores cresceu vertiginosamente nos últimos anos. As aplicações centralizadas em sensoriamento e controle avançaram com a instrumentação industrial, passando pela incorporação desses elementos em redes distribuídas até culminar, na atualidade, em redes integradas que possuem inúmeras funções e aplicações, dentre elas: controle, monitoramento, rastreamento e segurança. Entretanto o crescimento do número de sensores e atuadores conectados através de barramentos e redes não ocorreu de forma única, proliferando uma diversidade de formas de padronização na comunicação entre esses e seus respectivos monitores ou controladores. Dessa pluralidade de protocolos emergiu a necessidade de criação de um padrão que permitisse interoperabilidade entre transdutores e redes de controle, bem como a introdução do conceito de sensores e atuadores inteligentes. Nesse contexto foi proposto o protocolo IEEE1451 (Standards for Smart Transducer Interface for Sensors and Actuators). Nessa perspectiva o trabalho em questão apresenta os resultados do desenvolvimento e a utilização desse padrão em duas aplicações de engenharia biomédica. Primeiramente em um sistema embarcado capaz de realizar aquisição e processamento de biopotenciais, em específico, de eletrocardiogramas e a posterior transmissão dos dados coletados através de uma interface sem fio Wifi (IEEE802.11b/g) utilizando os protocolos IEEE1451.0 e IEEE1451.5. E em um eletrogoniômetro, para fins fisioterápicos, que realiza medidas de amplitude de movimento das articulações e transfere os dados serialmente através de uma interface USB (Universal Serial Bus) utilizando como padrões o IEEE1451.0 e o IEEE1451.2. Ambos os sistemas permitem além do monitoramento local, o acesso das informações coletadas pela Internet através de uma instrumentação remota implementada por um Web Service. Dessa maneira foi construída uma rede de sensores padronizada que permitiu demonstrar os benefícios e as potencialidades do protocolo IEEE1451. / The use of sensors and actuators grew vertiginously in recent years. The centralized applications in sensing and controlling advanced with industrial instrumentation, going through the incorporation of these elements into industrial computer network protocols until currently culminating in integrated networks with innumerable functions and applications, amongst them: controlling, monitoring, tracking and security. However, the growth of the number of sensors and actuators connected through bus and computers networks did not occur in a single way, and a diversity of communication standards proliferated. From these protocols, plurality required the creation of a standard to allow interoperability between transducers and networks, as well as the introduction of the smart sensors and actuators concept. In this context the IEEE1451 protocol (Standards for Smart Transducer Interface for Sensors and Actuators) was proposed. In this perspective, this work presents two applications of biomedical engineering using the IEEE1451 standard. The first application is an embedded system for biopotencial acquisition and processing, specifically, electrocardiogram signals and data transmission through a wireless interface Wifi (IEEE802.11b/g) using IEEE1451.0 and IEEE1451.5 protocols. The other application is an electrogoniometer, for physiotherapy, that measures the joint movements amplitude and transfers the data through an USB (Universal Serial Bus) connection using the IEEE1451.0 and the IEEE1451.2 protocols as standards. Both systems allow local monitoring and the access to information through a remote instrumentation implemented by Web Services. Hence, this project demonstrates the IEEE1451 benefits and the potentialities.
167

Uma Contribuição aos Sistemas de Monitoramento de Integridade Estrutural Baseados na Impedância Eletromecânica

Baptista, Fabricio Guimarães [UNESP] 08 January 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-01-08Bitstream added on 2014-06-13T18:40:52Z : No. of bitstreams: 1 baptista_fg_dr_ilha.pdf: 1105245 bytes, checksum: d9df8c940603a26591e01168eaac4aaa (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A técnica da impedância eletromecânica (E/M) tem sido amplamente pesquisada para o desenvolvimento de sistemas de SHM (Structural Health Monitoring – monitoramento de integridade estrutural) em diversas aplicações. Embora existam muitos trabalhos que indiquem a eficiência e a viabilidade dessa técnica, alguns problemas práticos em aplicações reais ainda precisam ser investigados. A medição da impedância elétrica, etapa básica da técnica, geralmente é realizada por instrumentos comerciais volumosos, pesados e de alto custo, características proibitivas para muitas aplicações. A seleção da faixa de frequência em que a impedância deve ser medida para assegurar boa sensibilidade ao dano é feita por métodos de tentativa e erro ou por metodologias que utilizam dados medidos em uma quantidade considerável de testes. Além disso, o dimensionamento dos transdutores é feito sem um embasamento teórico, independentemente das características da estrutura monitorada. Neste trabalho é proposto um sistema de medição de impedância elétrica rápido, versátil e de baixo custo que substitui com eficiência os instrumentos comerciais. A partir de um circuito eletromecânico equivalente, o efeito de carregamento do transdutor devido à estrutura monitorada foi analisado. A análise do efeito de carregamento permite dimensionar corretamente o transdutor de acordo com a estrutura monitorada e assegurar um bom desempenho do sistema. O circuito eletromecânico também foi utilizado para determinar, teoricamente, as faixas de frequência em que o transdutor tem boa sensibilidade e auxiliar na seleção da faixa de frequência adequada para a detecção de danos estruturais. Todas as metodologias propostas foram verificadas através de experimentos em estruturas de alumínio e houve uma boa concordância entre os resultados teóricos e experimentais / The electromechanical (E/M) impedance technique has been widely studied for the development of Structural Health Monitoring (SHM) systems in various applications. Although there are many studies indicating the effectiveness and feasibility of this technique, some practical issues in real applications yet should be investigated. The electrical impedance measurement, basic stage of the technique, is usually performed by bulky, heavy and expensive instruments; these features are prohibitive for many applications. The selection of the frequency range in which the electrical impedance must be measured to ensure good sensitivity for damage detection is performed by trial and error methods or by methodologies that use measured data in a considerable amount of tests. Furthermore, the design of the transducer is done without theoretical basis, regardless the characteristics of the host structure. In this work, a fast, versatile and low-cost electrical impedance measurement system was developed; the proposed system successfully replaces the conventional instruments. From an equivalent electromechanical circuit, the transducer loading effect due to the host structure was analyzed. The analysis of the loading effect allows the correct design of the transducer according to the host structure for ensure a good performance of the system. The electromechanical circuit was also used to theoretically determine the frequency ranges in which the transducer has good sensitivity and assist in the selection of the suitable frequency range for structural damage detection. All proposed methodologies were validated by experimental tests on aluminum structures and there was a good match between the theoretical and practical results
168

USO DA ONDA ULTRA-SÔNICA COMO MEIO DE CONTROLE DO PROCESSO DE SECAGEM DA MADEIRA / THE USE OF ULTRASONIC WAVE TO CONTROL THE DRYING WOOD PROCESS

Calegari, Leandro 21 February 2006 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The purpose of this study is to explore the use of ultrasonic technique in order to estimate the moisture content during wood drying, from green condition to the end of the drying process. The treatments were based on the combination of two different species (Pinus elliottii Engelm. and Eucalyptus grandis Hill ex Maiden), drying temperatures (20, 40 and 70ºC) and transducers types (plane faces and dry points). The experiment was set up according to a factorial model, with approximately 50 replications. A 50 kHz - transducer (PUNDIT ultrasonic equipment) was used. Samples tested had nominal 3.5 cm thick by 10 cm wide by 25 cm long and the ultrasonic wave speed propagation was measured according to its longitudinal direction. The results indicated increase of ultrasonic speed with reduction of moisture content for both transducers used. This relationship is valid for the wood from green to the end of the drying process. However, low correlation was observed, and the best model adjusted determination coefficients were observed with eucalypt wood (Raj.²= 88%). The use of the transducers of dry points was more practical than the plane faces one. Moreover, they should be used in hard and not much heterogeneous woods. The ultrasonic velocity was also influenced by wood density and drying temperature. The species showed different effects of wood density on the velocity. In the pine wood, velocity increased with increasing density. Opposing effect was observed in eucalypt wood. The ultrasonic speed tended to decrease as drying temperature increased. Nevertheless, this variable s influence was reduced. It was not noticed any defined influence of the species in the ultrasonic speed when the plane face transducers were used. However, the eucalyptus wood provided larger velocity when the dry point transducers were used. The results suggest that this method presents good potential for the control of the drying process. Studies on the influence of the several wood characteristics on the ultrasonic wave s velocity and the development of specific transducers for the use of this alternative in commercial scale are required. / O objetivo deste estudo foi explorar o uso da técnica ultra-sônica para estimar o teor de umidade da madeira durante sua secagem, desde a condição verde até o final do processo. Os tratamentos basearam-se na combinação de duas espécies (Pinus elliottii Engelm. e Eucalyptus grandis Hill ex Maiden), temperaturas de secagem (20, 40 e 70ºC) e tipos de transdutores (faces planas e pontos secos). O experimento foi estabelecido segundo modelo fatorial, com aproximadamente 50 repetições por tratamento. Utilizou-se um equipamento ultra-sônico PUNDIT, com transdutores de 50 kHz. As amostras testadas apresentaram dimensões nominais de 3,5 x 10 x 25 cm de espessura, largura e comprimento, respectivamente e a velocidade ultra-sônica foi determinada considerando-se o plano longitudinal. Os resultados indicaram aumento da velocidade ultra-sônica estimada em função da redução do teor de umidade, para ambos os transdutores. Esta relação apresentou-se válida para a madeira desde verde até o final da secagem. No entanto, foi observada baixa correlação, sendo que os melhores coeficientes de determinação ajustados ocorreram à madeira de eucalipto (Raj.²= 88%). O uso dos transdutores de pontos secos apresentou-se mais prático do que o uso do de faces planas, devendo ser utilizados em madeiras duras e pouco heterogêneas. A velocidade ultra-sônica também foi influenciada pela densidade da madeira e pela temperatura de secagem. As espécies proporcionaram efeitos distintos da densidade sobre a velocidade. Na madeira de pinus, a velocidade aumentou com o aumento da densidade, ao passo que na de eucalipto ocorreu efeito inverso. A velocidade ultra-sônica apresentou tendência de redução em virtude do aumento da temperatura de secagem. No entanto, a influência desta variável foi reduzida. Não foi observada influência definida das espécies sobre a velocidade ultra-sônica quando utilizados os transdutores de faces planas. Porém, a madeira de eucalipto proporcionou maior velocidade quando utilizados os transdutores de pontos secos. Os resultados sugerem que este método apresenta bom potencial para ser usado no controle do processo de secagem. Entretanto, são necessários estudos sobre a influência das diversas características das madeiras sobre a velocidade das ondas ultra-sônicas, bem como o desenvolvimento de transdutores específicos para o uso desta alternativa em escala comercial.
169

Implementação de um nó IEEE 1451, baseado em ferramentas abertas e padronizadas, para aplicações em ambientes de instrumentação distribuída

Rossi, Silvano Renato [UNESP] 14 January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-01-14Bitstream added on 2014-06-13T18:42:30Z : No. of bitstreams: 1 rossi_sr_dr_ilha.pdf: 2325960 bytes, checksum: 7ef7ad22ede243a4f480a84cc0e63023 (MD5) / Universidad Nacional de Asuncion / Atualmente, as redes de transdutores inteligentes desempenham um papel de importância vital em sistemas de Medição e Controle Distribuído. Nesse contexto, o Padrão IEEE 1451 para interfaceamento de transdutores inteligentes tem como objetivo simplificar a conectividade de transdutores em ambientes de rede, fornecendo, para tal fim, um conjunto de interfaces padronizadas, aumentando a flexibilidade dos sistemas de instrumentação distribuída. Neste trabalho descreve-se a implementação de um nó de rede em conformidade com o padrão IEEE 1451. O nó foi completamente desenvolvido através do emprego de ferramentas padronizadas e sistemas abertos. O nó é composto por um Processador de Aplicação com Capacidade de Operar em Rede (NCAP), com base no padrão IEEE 1451.1 e um Módulo de Interface para Transdutores Inteligentes (STIM), em conformidade com o padrão IEEE 1451.2. A parte física do NCAP foi implementada através dos recursos de um Computador Pessoal (PC) e de um Dispositivo Lógico Programável (PLD) de uso geral. A parte lógica do NCAP foi desenvolvida através da tecnologia Java. O STIM foi implementado com dispositivos lógicos programáveis versáteis, de uso geral, e sua funcionalidade foi integralmente descrita em linguagem de descrição de hardware. O conjunto NCAP-STIM foi conectado a uma rede de área local, sob o modelo de comunicação cliente-servidor, sendo que várias aplicações clientes podem acessar as informações dos transdutores conectados ao STIM, através da rede, via intermediação do NCAP. O emprego de ferramentas padronizadas e abertas no desenvolvimento total do sistema IEEE 1451 é uma das contribuições mais importantes do presente trabalho. No entanto, há várias contribuições pontuais como: a maneira de descrever as Informações de Transdutores em Formato Eletrônico (TEDS), a implementação... . / Nowadays, smart transducer networks play an essential role in distributed measurement and control systems. In this context, the IEEE 1451 smart transducer interface standards aimed to simplify transducer connectivity, providing a set of common interfaces for connecting transducers in a networked fashion, increasing the flexibility of distributed instrumentation systems. In this work the implementation of a network node according to the IEEE 1451 standard is introduced. The node has been fully developed using open and standardized tools. A Network Capable Application Processor (NCAP) according to the IEEE 1451.1 Standard and a Smart Transducer Interface Module (STIM) comprises the node. The physical part of the NCAP has been implemented using the resources of a Personal Computer (PC) and a general-purpose Programmable Logic Device (PLD). The logical part of the NCAP has been developed using Java technology. The STIM module was implemented with versatile, general-purpose Programmable Logic Devices. STIM functionality has been fully developed in hardware description language. A network node (STIM-NCAP) was connected in a client-server modelbased local area network. Many client applications can access STIM transducers information, through the network with the NCAP as an intermediary. One of the most important contributions of this work is the employment of open and standardized tools for implementing the IEEE 1451 network node. However, there are many specific contributions such as: Transducer Electronic Data Sheet (TEDS’s) description method, programmable logic-based Protocol Manager implementation that allows the use of the parallel port without any modification, the employment of low-cost PLDs for implementing the STIM and the Protocol Manager, and Java-based NCAP software development. Through the implementation of the IEEE Standard, industries... (Complete abstract, click electronic address below).
170

Projeto de controladores robustos para aplicações em estruturas inteligentes utilizando desigualdades matriciais lineares

Silva, Samuel da [UNESP] 21 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-21Bitstream added on 2014-06-13T19:55:35Z : No. of bitstreams: 1 silva_s_me_ilha.pdf: 1382147 bytes, checksum: 3fda6ad8742fdeab5c8e0db680440cbe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho tem como propósito utilizar técnicas de controle robusto para atenuação ativa de vibração mecânica em estruturas acopladas a atuadores e sensores piezelétricos. Os controladores são projetados segundo o enfoque de otimização convexa, com os requisitos envolvendo desigualdades matriciais lineares (LMIs). A proposta é ilustrar duas sínteses diferentes de realimentação via LMIs. A primeira é o projeto de controladores por realimentação de estados, estimados por um observador, considerando incertezas paramétricas do tipo politópicas. A segunda metodologia é baseada no controle H8 via realimentação do sinal de saída, considerando incertezas dinâmicas limitadas por norma. Os sensores/atuadores são posicionados em pontos ótimos utilizando-se a norma H8 como índice de desempenho. Os modelos matemáticos utilizados na síntese dos controladores foram obtidos a partir do método dos elementos finitos considerando o acoplamento eletromecânico entre os atuadores/sensores e a estrutura base ou a partir de métodos de identificação. Neste contexto, este trabalho também discute e exemplifica o algoritmo de realização de autosistemas (ERA). Três exemplos são solucionados para exemplificar a metodologia implementada: uma estrutura tipo placa, uma viga engastada-livre e a supressão ativa de flutter em um aerofólio 2-D, problema de grande interesse na indústria aeronáutica. Os resultados mostraram uma significante atenuação da vibração estrutural na faixa de freqüência de interesse e o atendimento dos requisitos impostos na fase de projeto. / The proposal of this work is to use robust control techniques in order to suppress mechanical vibration in structures with pieozoelectric sensors and actuators coupled. The controllers are designed by convex optimization and the constraints are dealt through linear matrix inequalities (LMIs) frameworks. Two different methodologies to feedback the system by using LMIs are explained. The first one is the observer-based state-feedback considering polytopic uncertainties. The second one is the H output feedback control considering norm-bound uncertainties. The sensors/actuators are located in optimal placements by using H norm as performance index. The mathematical models used in the controller design were obtained by finite element methods considering eletromechanical effects between the host structure and piezoelectric sensors/actuators patches or by using identification methods. In this sense, it is also discussed the eigensystem realization algorithm (ERA). Three different applications are proposed and solved in order to illustrate the applicability of the methodology: a cantilever plate; a cantilever beam; and an active flutter suppression in a 2-D airfoil, a problem of considered interest in the aeronautic industry. The results showed the vibration suppression in the bandwidth of interest when submited to the requirements imposed by practical situations.

Page generated in 0.1035 seconds