• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 804
  • 767
  • 365
  • 83
  • 44
  • 33
  • 32
  • 29
  • 18
  • 17
  • 16
  • 11
  • 8
  • 8
  • 7
  • Tagged with
  • 2476
  • 409
  • 342
  • 304
  • 257
  • 219
  • 200
  • 195
  • 181
  • 170
  • 142
  • 130
  • 127
  • 109
  • 108
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Rebranding značky: prípadová štúdia Garnier / Rebranding: Garnier case study

Veselý, Radovan January 2011 (has links)
The thesis is about the topic of rebranding on a concrete case from the Czech Republic. The main goal of this thesis is to find a strategy for the rebranding campaign of the Garnier Naturals brand. The key benefits of the paper are the summarization of the rebranding process in general as well as concrete process for the Garnier Naturals brand. In the theoretical part of the paper is the theory behind brands and case studies about both successful and unsuccessful rebranding. In the application part there is an image study of the original brad as well as an analysis of quantitative research and qualitative research -- focus groups. The most important learnings and a proposed strategy for this particular rebranding is in the last part of the paper - the summary.
42

SPEM, sistema pulso-eco microcontrolado para geração e medição de campos ultra-sonicos

Maia, Joaquim Miguel 23 February 1995 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T22:25:02Z (GMT). No. of bitstreams: 1 Maia_JoaquimMiguel_M.pdf: 7879185 bytes, checksum: d81c83b96f5059062de96632b0410c74 (MD5) Previous issue date: 1995 / Resumo: Para uma melhor compreensão e confiabilidade no processamento das informações obtidas pela radiação ultra-sônica, torna-se muito importante o entendimento dos princípios básicos da geração de ondas ultra-sônicas bem como sua interação e propagação através dos mais diversos meios. Isto pode ser parcialmente alcançado através da utilização de equipamentos adequados e um amplo conhecimento das suas características de operação. Tendo como objetivo a medição e o estudo de características ultra-sônicas de diferentes materiais, foi desenvolvido um Sistema Pulso-Eco Microcontrolado (SPEM) para geração e recepção de sinais de radiofreqüência (RF) na faixa do ultra-som para diagnóstico médico. O "hardware" do sistema desenvolvido é formado por circuitos de transmissão, circuitos de recepção, circuitos de controle e de interfaceamento. Os circuitos de interfaceamento e controle foram desenvolvidos utilizando-se o microcontrolador MC68HCII-Al da Motorola, "drivers" e circuitos de apoio para implementar a Interface Padrão IEEE-488 ("General Purpose Interface Bus" - GPIB). O SPEM pode ser operado tanto por controle remoto, via interface GPIB, como por controle local via teclado e chaves no painel frontal do mesmo. O "software" para controle local foi escrito na linguagem Assembly do MC68HCll e o "software" para controle remoto via interface GPIB foi desenvolvido utilizando-se a linguagem de programação C e é executado em um computador compatível com o IBM PC, equipado com uma interface da Hewlett-Packard modelo HPIB 82335A. O microcomputador opera como controlado r do barramento GPIB. Os circuitos de transmissão são capazes de gerar pulsos com largura de 330 ns e amplitude controlada entre 15 V e 200 V ou pulsos de 200 ns, 300 ns, 400 ns, 500 ns, 600 ns e 700 ns com amplitude controlada entre 2 V e 28.4 V. Os circuitos de recepção podem amplificar sinais de RF com freqüências entre 10 kHz e 10 MHz em 25 ganhos distribuídos na faixa entre 0.6 V/V e 3730 V/V (-4.4 dB a 71.5 dB). Os testes para avaliação de desempenho do sistema foram realizados no Laboratório de Ultra-som do Centro de Engenharia Biomédica da Unicamp (LUS-CEB) com a geração e recepção de ondas ultra-sônicas em meio líquido, utilizando-se um transdutor circular de 1 MHz colocado em contato com um cilindro de alumínio. Estes testes mostraram que o equipamento pode ser utilizado para fins de pesquisa em laboratório / Abstract: In order to obtain more reliability in the processing of information obtained by ultrasound radiation, it is very important to understand the basic principIes of ultrasound wave generation, interaction with and propagation through different media. This can be partially achieved with suitable equipments and a good knowledge of its working conditions. In an effort to measure and study ultrasonic features of different materiaIs, we have developed a Pulse-Echo Microcontrolled System (SPEM) for generation and reception of RF signals in the range ofultrasound medical diagnosis. The hardware consists oftransmission, reception, control and interfacing circuits. The control and interfacing circuits were developed with a Motorola MC68HCII-Al microcontroller and proper circuitry to implement the IEEE Standard 488 (General Purpose Interface Bus - GPIB). The SPEM is fully controlled via remote mode through the GPIB interface, and permits local control with proper keys in the front pane!. Special software has been developed Ín C-language to run in an IBM-PC compatible microcomputer, working as GPIB controller and equiped with a HPIB 82335A interface model of Hewlet-Packard. The SPEM control software has been written in MC68HC11 assembly language. The transmitting circuit emits pulses 330 ns wide with an amplitude that may be controlled from 15 V to 200 V or pulses 200 ns, 300 ns, 400 ns, 500 ns, 600 ns and 700 ns wide with an amplitude controlled from 2 V to 28.4 V. The receiving circuit amplifies RF signals in the range of 10 kHz to 10 MHz from 0.6 V/V to 3730 V/V (-4.4 dB to 71.5 dB) in 25 steps. The system was tested with a 1 MHz transducer facing an aluminun rod, both immersed in water. Ultrasound waves have been generated and received by the system which has presented good performance. The results have shown that the equipment may be used for research purposes in the Ultrasound Laboratory of the Centre for Biomedical Engineering at Unicam / Mestrado / Automação / Mestre em Engenharia Elétrica
43

"Ultra-sonografia recurso imaginológico aplicado à odontologia" / Ultrasonography – imaginologic resource applied to dentistry Odontologia.

Thásia Luiz Dias Ferreira 01 April 2005 (has links)
O ultra-som é um recurso imaginológico relativamente recente, que foi desenvolvido primeiramente para utilização submarina, e só depois fundamentada na área da Saúde. Esse sistema utiliza ondas ultra-sônicas, que são produzidas em um dispositivo denominado transdutor, responsável também por enviá-las ao tecido a ser avaliado; é também o responsável por receber os ecos sonoros que são refletidos pelas estruturas que possuem diferentes impedâncias acústicas, obtendo-se assim os resultados. As primeiras gerações de US (modo-A) utilizavam um sistema numérico pouco atrativo para a interpretação dos resultados. Somente com o advento do modo-B, que apresenta imagens tomográficas, o ultra-som começou a se tornar um método imaginológico mais utilizado. Com a evolução dos aparelhos, a técnica permitia que as imagens fossem processadas a uma velocidade suficientemente rápida para deixar passar a percepção de movimento. É possível por meio do Doppler colorido, caracterizado pela associação das imagens em movimento em tempo real, mapear o fluxo vascular. Pela revisão da literatura, concluímos que: o ultra-som é um exame imaginológico recente; é um método auxiliar na elaboração do diagnóstico, não invasivo, indolor e sem nenhum efeito deletério conhecido até os dias atuais; é um exame imaginológico com alta especificidade para tecidos moles; é um recurso capaz de detectar, delimitar 9 (inclusive em profundidade) e avaliar o conteúdo interno, tanto na normalidade quanto nas alterações do complexo dento-maxilo-cervico-facial; a interpretação pode ser feita em tempo real, sendo passível de repetição, sempre que necessário; é operador-dependente e tem ampla aplicação nas diferentes Especialidades Odontológicas. / The Ultrasound (US) is a relatively recent imaginologic resource that was first developed for submarine use, and then applied in the Health area. This system makes use of ultrasonic waves, produced in a device called transducer, which is also responsible for sending them to the tissue to be evaluated. The transducer is responsible for receiving the eco sounds that are reflected by structures that possess different acoustic impedances, thus obtaining results. The first generations of US (A-mode) used a numerical system that was not very attractive for results interpretation. Only with the discovery of the B-mode, which presents tomographic images, the ultrasound started to become a more utilized method. As devices evolved, the technique allowed images to be processed in such a high velocity that would let the perception of movement pass. It is possible to map the vascular flux in real time by using Coloured Doppler, characterized by the association of moving images. By literature review, we concluded that: the ultrasound is a recent imaginologic exam; it is a non-invasive, painless, auxiliary diagnostic method and has shown no known side effects until the present date; it is a high-specificity imaginologic exam for soft tissues; it is a resource capable to detect, delimitate (including in depth), and evaluate the internal content in normality as much as in dento-maxilo-cervico-facial alterations; the interpretation can be made in real time, and repetition is always 11 possible when necessary; it is operator-dependent and has a wide application in different odontological specialities.
44

Projeto de um sistema ultra-sonico doppler pulsatil para avaliação da vascularização periferica

Gamba, Humberto R 09 June 1989 (has links)
Orientador : Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T20:51:19Z (GMT). No. of bitstreams: 1 Gamba_HumbertoR_M.pdf: 9020235 bytes, checksum: f58f0f0b6af91cdd429e14d1ee2e9ab9 (MD5) Previous issue date: 1989 / Resumo: A utilização de sistemas ultra-sônicos, baseados no princrpio Doppler, para detecção de estenoses arteriais, constitui uma área de grande interesse no diagnóstico médico. Os equipamentos de fabricação nacional para esta finalidade trabalham com emissão e recepção de ultra-som no modo contínuo. Devido à esta característica, estes sistemas só conseguem detectar a existência de turbulências produzidas por obstruções que comprometem praticamente 50 % da luz do vaso. Os Com a finalidade de detectar a presença de turbulências produzidas por estenoses de pequeno grau (menores que 30%), projetou-se e construiu-se a primeira parte de um sistema ultra-sônico Doppler pulsátiI de múltiplos canais. O protótipo, embora ainda com apenas um canal , é capaz de analisar lâminas de fluxo com espessura de aproximadamente 2,3 mm (ângulo de incidência de 75 graus) em profundidades de até 70 mm. Seu sistema de controle permite a ampliação até o máximo de 15 canais. O transdutor utilizado neste equipamento possui um único cristal, tanto para emissão quanto para recepção, emitindo pulsos ultra-sônicos de 5 MHz em intervalos fixos de 50 µ ou 100 , sendo a duração de cada pulso ajustável entre 0,1 e 1 µ . Os resultados obtidos com este primeiro protótipo, demonstram a capacidade do sistema em detectar turbulências produzidas por obstruções de até 22 % de comprometimento da luz do vaso / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
45

Estudo comparativo de sistemas a base de lasers, leds e ultra-som (US) de baixa intensidade no reparo tecidual em tendão calcâneo / Comparative study of Laser, LED and US systems of low intensity applied to tendon healing

Jessica Lucia Neves Bastos 05 August 2008 (has links)
Um dos recursos mais utilizados no processo de reparo de lesões tendíneas é o laser que demonstrou ter resultados satisfatórios quando se buscam efeitos antiinflamatório e cicatrizante. No entanto, por requerer uma tecnologia de alto custo, um outro tipo de fototerapia vem sendo buscado, como o diodo emissor de luz, LED. Porém, o número de pesquisas realizadas para a determinação segura de seus efeitos terapêuticos ainda é muito pequeno, inviabilizando uma proposta de protocolo para adoção do LED. Um outro recurso também utilizado durante a reabilitação de lesões tendíneas, é o ultra-som pulsado de baixa intensidade (LIPUS). Trabalhos realizados até o momento mostram alterações satisfatórias quanto à deposição e alinhamento das fibras de colágeno. Este estudo objetiva testar comparativamente a eficácia da aplicação de LEDs 630 nm e 830 nm em relação à terapia laser de baixa intensidade (LILT), com laser de 685 nm e 830 nm, e à terapia com LIPUS em tendão calcâneo parcialmente lesado. Foram utilizados 56 ratos Wistar, submetidos à lesão mecânica parcial do tendão calcâneo. A análise da evolução do processo foi realizada através da microscopia de polarização. Os resultados mostraram uma real eficácia dos tratamentos com LEDs e lasers, e uma ineficácia do tratamento à base de US. Nosso estudo sugere que uma boa organização e um bom alinhamento das fibras de colágeno são conseguidos no processo de reparo de lesões tendíneas através de aplicações à base de LED 880 nm e laser 630 nm, os quais se mostraram mais eficazes. No entanto, outras pesquisas na área se fazem necessárias para uma determinação segura e eficaz dos protocolos de tratamento utilizando essa modalidade de fototerapia. / Laser is one of the most effective resources of treatment for tendinous injury when anti-inflammatory and cicatrizing effects are wanted. However, it is considered an expensive treatment and so, an alternative and cheaper light therapy as effective as it has been searched and the light emitting diodes, LEDs, are a promising candidate for it. Results from the studies already done have been useful to predict the possible effects of LED on the injured tissues, but are not enough to establish a treatment protocol that guarantees its recommendation as a substitute therapeutic tool for tendinous injury treatment. Another promising resource for tendinous injury healing is the ultra-sound of low intensity (LIPUS). Studies done until the present moment have shown satisfactory results when deposition and alignments of collagens fibers are wanted. The aim of this study was to compare the effects of laser, light emitting diodes (LEDs) and ultra-sound of low intensity on the treatment of Achilles tendon of albino rats, Wistar lineage, exposed to mechanical trauma. The experimental model consisted of a partial mechanical lesion of the right Achilles tendon of 56 rats, which were divided in 6 groups, 5 with 10 animals and one, the control group, with 6. One hour after the lesion, the injured animals received the respective applications of laser, LED or US, and the same procedure was repeated each 24 h. The healing process and the deposition were evaluated by analyze of the alignment of collagens fibers through polarization microscopy. The results showed a real efficiency of treatments based on LEDs and lasers, but the treatment based on US was inefficient. Applications of laser at 830 and LED 880 nm were more efficient when the aim is a good organization and alignment of the collagen fibers on tendon healing. However more research is needed for a safety and more efficient determination of a protocol.
46

Molecular structure and predissociation dynamics studied using absorption spectroscopy and ion imaging

Howie, Wendy Helen January 2001 (has links)
No description available.
47

UHV studies of the adsorption of small adsorbate molecules on low index platinum single crystals

Baily, Christopher John January 2003 (has links)
No description available.
48

Amplification d’impulsions ultra-courtes en régime non-linéaire dans les fibres dopées aux ions Ytterbium

Zaouter, Yoann alain 05 December 2008 (has links)
L’élaboration de sources laser compactes à impulsions ultracourtes et de fortes puissancesmoyennes est primordiale pour le développement d’applications industrielles variéeset pour la poursuite de travaux de recherches fondamentales sur l’interaction laser matière.Aussi, des efforts considérables sont mis en oeuvre pour développer de nouvelles architecturesde sources laser à impulsions ultracourtes et à très hautes cadences basées sur lesamplificateurs à fibres optiques dopées aux ions Ytterbium. La géométrie de ce type de milieuamplificateur lui confère des facultés de dissipation de l’énergie thermique propices àla délivrance de très fortes puissances moyennes. En revanche, le fort confinement des impulsionslumineuses dans le coeur de la fibre, combiné aux grandes longueurs d’interaction,favorise l’accumulation de phénomènes non-linéaires et dispersifs. Ces deux effets sont enprincipe préjudiciables et induisent de fortes distorsions sur les impulsions amplifiées. Celalimite les performances de ce type d’amplificateur. Le développement de stratégies novatricesde gestion des non-linéarités et des effets dispersifs est au coeur des travaux menésdurant cette thèse.L’accumulation d’auto-modulation de phase lors de l’amplification d’impulsions à spectreslarges initialement étirées à l’aide d’une dérive de fréquence négative est d’abord utiliséepour générer des impulsions picoseconde de puissances crêtes records à très hautes cadencesavec une largeur spectrale proche de la limite de Fourier. Par la suite, l’étude des limitationsde la stratégie d’amplification directe d’impulsions femtoseconde en régime parabolique, apermis de repousser significativement les performances de ces architectures. En prenant encompte les effets coopératifs de l’auto-modulation de phase, de la dispersion, de l’extensionfinie de la bande de gain du milieu amplificateur, nous avons pu générer des impulsionssub-100 fs avec des puissances crêtes records à des cadences très élevées. Enfin, nous avonsdéveloppé au cours de ces travaux une stratégie originale d’amplification à dérive de fréquenceen régime non-linéaire fondée sur l’utilisation de systèmes désaccordés de gestionde la dispersion. Cela nous a permis de compenser la phase non-linéaire induite durantl’amplification. Des impulsions de très fortes énergies et dotées d’une très bonne qualité177178 CHAPITRE 6. CONCLUSIONtemporelle ont été générées permettant ainsi d’établir de nouveaux records d’énergie et depuissance crête pour ce type d’architecture.Les résultats expérimentaux ont abouti à la rédaction de onze articles et ont conduitau dépôt de deux brevets. Par ailleurs, ces résultats ont été présentés dans trente-quatreconférences (dont six conférences invitées). Enfin, ils ont permis à la société AmplitudeSystemes de procéder à la mise sur le marché de deux nouvelles gammes de produits :TANGERINE et SATSUMA / The elaboration of high power compact laser sources of ultrashort pulses is paramountfor the development of various industrial applications and for carrying on fundamental researcheson laser-matter interaction. Therefore, considerable efforts are implemented todevelop new architectures of ultrafast laser sources at very high repetition rate based onYtterbium-doped fiber laser amplifiers. The geometry of this gain medium allows for aneasy dissipation of the thermal load, propitious to the extraction of very high average power.On the other hand, the tight confinement of the ultrashort pulses in the core of thefiber, combined with the long interaction length, favours the accumulation of non-linearand dispersive phenomena. In principal, these two effects are prejudicial and induce largedistortions on the amplified pulses, limiting the performances of this kind of amplifiers.The development of new strategies of non-linearity and dispersive effects management aretherefore central in this thesis.First, the accumulation of self-phase modulation during the amplification of ultrashortpulses with large spectra, which are initially stretched in time owing to negative chirp, isused to generate record peak power picosecond pulses at very high repetition rate with anamplified spectral bandwidth close to the Fourier limit. Afterwards, the study of the limitationsof the direct amplification of femtosecond pulses in the parabolic regime allows tosignificantly pushing the limitations of this kind of architecture forward. By taking into accountthe interplay between self-phase modulation, dispersion and the finite gain bandwidthof the amplification medium, we generated sub-100 fs pulses with record peak power at veryhigh repetition rate. Finally, we developed an original chirped pulse amplification strategybased on the management of non-linearities thanks to the implementation of mismatcheddispersion units. It allows for the compensation of a large quantity of non-linear phase shiftsgenerated during the amplification. We, thus, demonstrated the generation of high energy,high temporal quality ultrashort pulses while setting new records of peak power.The experimental results led to the writing and the publication of eleven articles andthe filling of two patents. Moreover, these results were presented in thirty four conferences179180 CHAPITRE 6. CONCLUSION(including six invited conferences). As a result Amplitude Systemes has launched into themarket two new lines of products : TANGERINE and SATSUMA.
49

"Avaliação de retropreparos confecionados por pontas de ultra-som lisas, diamantadas e despolidas" / Evaluation of retropreparations carried out with smooth ultrasound, diamond coated and no polished tips

Salzano, Karina 15 February 2006 (has links)
Diante das vantagens do uso do ultra-som na confecção de cavidades retrógradas, o presente estudo avaliou pontas lisas, diamantadas e despolidas quanto ao tempo usado para confecção das cavidades, presença de sujidade e infiltração do corante rodamina a 0,2%. Após os tratamentos endodônticos e apicectomias dos trinta e quatro dentes uniradiculares estudados, estes foram divididos em três grupos de 10; de acordo com a ponta usada para o retropreparo. A confecção das cavidades retrógradas consistiu de duas fases: fase 1 (a ponta de ultra-som deveria atingir 3mm de profundidade, não visualização de sujidade a “olho nu", preparo com características de classe I), e fase 2 (uso da ponta de ultra -som correspondente a cada grupo por mais 40 segundos). Ao final de cada fase, os espécimes foram avaliados sob microscópio óptico com aumento de 20X e fotografados. Quatro examinadores analisaram a presença de sujidade nas superfícies retropreparadas. O tempo gasto para a confecção da fase 1 foi anotado. Em seguida, todos os espécimes submeteram-se a retrobturação com MTA. Passado período de 72 horas, foram imersos em solução de rodamina a 0,2% e clivados após 24 horas. A hemi-parte que continha maior infiltração de cada espécime, foi a considerada. Os resultados mostraram que as pontas despolidas necessitam de menos tempo para confecção de cavidades retrógradas. Após mais 40 segundos de preparo (fase 2), houve diminuição na quantidade de sujidade, em todos os grupos, não havendo diferença estatística significante entre os grupos. Em relação a infiltração do corante rodamina a 0,2%, os resultados mostraram não haver diferença estatística significante, quando da comparação entre os preparos confeccionados por pontas lisas, diamantadas e despolidas e retrobturados pelo MTA. Concluímos, portanto, que o tipo de ponta de ultra-som influencia no tempo de preparo, apesar de não exercer influência na infiltração do MTA. Vale ressaltar que a presença de sujidade é intensamente minimizada quando da complementação dos preparos por mais 40 segundos. / Given the advantages of the use of ultrasound in the preparation of retrograde cavities, the present study evaluated the smooth, diamond -coated and use of no polished tips regarding the time required for the preparation of cavities, the presence of dirt and the penetration of the 0,2% rhodamine dye solution. After the apicectomy and endodontic treatment of the thirty-four single -rooted teeth studied, we divided them into 3 groups of 10 according to the tip used in the rootend preparation. Four roots were used as positive and negative controls. The preparation of the retrograde cavities consisted of two phases: phase 1 (the ultrasound tip should reach 3mm of depth; dirt should not be spotted by the naked eye; preparation with class I characteristics), and phase 2 (use of the ultrasound tip corresponding to each group for more than 40 seconds). At the end of each phase, the specimens were evaluated under an optical microscope that enhanced them 20X, and were then photographed. Four examiners analyzed the presence of dirt in the root-end preparation surfaces. The time spent in phase 1 was recorded. All the specimens were then root-end filling with MTA. After 72 hours, they were submerged in a 0,2% rhodamine solution and cleaved after 24 hours. We then analyzed the hemi-part that contained the highest penetration. The results showed that the no polished tips require shorter time in the preparation of retrograde cavities. After over 40 seconds of preparation (phase 2), there was a reduction in the amount of dirt in all the groups studied, with no signify cant differences between the groups. As regards the penetration of the rhodamine dye at 0,2%, the results did not show statistically significant differences as regards preparations with smooth, diamondcoated and no polished tips, and root-end filling with MTA. Therefore , we concluded that the type of ultrasound tip influences the preparation time, even though it has no influence on the penetration of MTA. It is important to stress that the presence of dirt is highly minimized when the preparation is complemented by 40 more seconds.
50

Implementação do processo de medição por ultra-sons

Malheiro, Elói Oliveira January 2008 (has links)
Estágio realizado na Gestamp Portugal e orientado pelo Eng.º António Alexandre M. Gonçalves / Tese de mestrado integrado. Engenharia mecânica. Faculdade de Engenharia. Universidade do Porto. 2008

Page generated in 0.0711 seconds