• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 804
  • 777
  • 365
  • 83
  • 44
  • 33
  • 32
  • 29
  • 18
  • 17
  • 16
  • 11
  • 8
  • 8
  • 8
  • Tagged with
  • 2486
  • 419
  • 342
  • 304
  • 259
  • 219
  • 200
  • 195
  • 181
  • 170
  • 142
  • 136
  • 127
  • 110
  • 108
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Dinâmica ultra-rápida em nanopartículas metálicas

Heráclyto Gonçalves de Miranda, Marcio January 2004 (has links)
Made available in DSpace on 2014-06-12T18:07:44Z (GMT). No. of bitstreams: 2 arquivo7901_1.pdf: 1383762 bytes, checksum: 14b73ee9e1c735d727a35c45cb59a2a4 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2004 / O objetivo desta dissertação é o estudo da dinâmica ultra-rápida de colóides de nanopartículas de prata suspensas em água e as alterações desta dinâmica quando os colóides são modificados por ablação a laser. O processo de ablação de laser desenvolvido pelos membros do Grupo de Óptica do DF-UFPE que forneceram as amostras permite modificar a distribuição de tamanhos e formas das nanopartículas de prata em solução. Nesta dissertação estudamos como estas modificações alteram a resposta ultra-rápida deste tipo de sistema, através da técnica de excitação-prova. Nos experimentos descritos aqui, usamos uma variação desta técnica em que as freqüências centrais dos pulsos de excitação e sonda são ? e 2?, respectivamente. Com isto a excitação deve-se a um processo de absorção intrabanda ( absorção por portadores livres ) e a fraqüência do feixe de sonda está próxima da freqüencia do plasmon. Além disto, realizamos medidas com diferentes polarizações do pulso de sonda, para estudar a anisotropia induzida pelo pulso de excitação. Variando o comprimento de onda do feixe de prova em torno das freqüências de ressonância dos plasmons das nanopartículas, foi possível verificar que a anisotropia induzida aumenta para fótons de menor energia, principalmente no caso das amostras não-tratadas por ablação. Com relação aos tempos de relaxação, que são da ordem de 1 ps, verificamos sensíveis alterações ao comparamos colóides antes e depois do processo de ablação. Para explicar as principais diferenças entre os colóides tratados e os não-tratados desenvolvemos um modelo simples que leva em conta a interação entre nanopartículas elipsoidais e o pulso de excitação. A dinamica da população eletrônica excitada é tratada usando o modelo de duas temperaturas, em que os elétrons possuem uma temperatura Te, maior que a temperatura da rede cristalina, Tr, e que estes dois sistemas trocam calor e eventualmente termalizam. Isto permite descrever o comportamento da ressonância de plasmon em função do tempo, e explicar nossas observações experimentais. Também descrevemos um modêlo bi-modal para os tamanhos das partículas, mostrando que há a possibilidade de que as partículas maiores dominem o espectro de absorção linear e as menores dominam o espectro de absorção não-linear
32

Desempenho do ultra-som pre-natal como metodo para diagnostico de cromossomopatias fetais

Ribeiro, Sara Tosetti 03 November 1998 (has links)
Orintadores: Ricardo Barini, Anibal Faundes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-24T10:04:16Z (GMT). No. of bitstreams: 1 Ribeiro_SaraTosetti_M.pdf: 2381476 bytes, checksum: 2ea16e35e582cedfd8448e59074dac4a (MD5) Previous issue date: 1998 / Resumo: Resumo: Com o objetivo de determinar o desempenho do ultra-som para detecção de gestações que apresentem risco de anomalia citogenética fetal, estudou-se retrospectivamente um grupo de 454 pacientes submetidas ao cariótipo fetal nos últimos cinco anos no Centro de Atenção Integral à Saúde da Mulher da Universidade Estadual de Campinas e no Centro de Diagnóstico Pré-Natal e Medicina Fetal (FETUS) em São Paulo. Desta população, 291 gestantes foram submetidas à coleta de material fetal para exame citogenético por ultra-som alterado e 163 por ansiedade parental, apresentando resultado de ultra-som morfológico normal. Avaliou-se a sensibilidade e especificidade do ultra-som utilizando o cariótipo fetal como padrão-ouro. Calculou-se o risco relativo de anomalia citogenética apresentado segundo o sistema acometido e segundo cada malformação fetal diagnosticada ao ultra-som. Compararam-se ainda os riscos de acordo com a presença de uma ou mais malformações. Para análise estatística foi utilizado o Programa EPI-INFO 6.0. Foram utilizados os testes de Qui-Quadrado para tabelas 2x2, além da avaliação de risco relativo. Observou-se que os maiores riscos ocorreram para as malformações de face, parede abdominal, aparelho cardiovascular e anomalias de membros. Anomalias de pulmão, trato urinário, sistema nervoso central, pescoço e trato gastrointestinal apresentaram riscos semelhantes, pouco inferiores aos primeiros. Alterações morfológicas de genitália, tórax, coluna e músculo-esqueléticas ocorreram em um pequeno número de casos, não sendo possível calcular o risco de cromossomopatia para estas alterações. Sempre que ocorreu associação de alterações morfológicas, o risco de cromossomopatia foi maior. Concluiu-se que o ultra-som apresentou um bom desempenho na detecção de gestações de risco para cromossomopatia / Abstract: The objective of this study was to determine the performance of ultrasound in detecting risk pregnancies as to fetal cytogenetical abnormality. A group of 454 patients was retrospectively studied. They underwent ultra-sound and fetal karyotype over the last five years. A total of 291 women presented abnormal ultrasound and 163 presented normal ultrasound. Ultrasound specificity and sensitivity were determined in order to identify fetal abnormal karyotype, having fetal karyotype as the gold standard. The relative risk of cytogenetical abnormality was estimated for each anomalous fetal system and for each fetal malformation diagnosed by ultra-sound. The risks were estimated by the presence of one or more fetal malformation diagnosed by ultrasound. Statistical analysis was performed with the software EPI-INFO 6.0 (Public domain). The highest risks were observed in the case of fetal facial malformations, abdominal wall malformations, cardiovascular and limb abnormalities. Malformations in lungs, urinary tract, central nervous system, neck and gastrointestinal tract, presented similar risks but inferior to the first ones mentioned. Genitalia, thorax, spinal column, skeleton and muscle malformations occurred in small numbers and their relative risks were not estimated. The risk of fetal chromosomal abnormalities was always higher in the presence of multiple anomalies detected by ultrasound. It was concluded that ultrasound had a good performance in detecting risk pregnancies as to fetal cytogenetical abnormalities / Mestrado / Tocoginecologia / Mestre em Ciências Médicas
33

Metodologia para avaliação de fluxo sanguineo em cirurgias vasculares com Doppler de ondas continuas

Freire, Paulo Celso Budri 11 August 1989 (has links)
Orientador : Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T01:28:41Z (GMT). No. of bitstreams: 1 Freire_PauloCelsoBudri_M.pdf: 7921683 bytes, checksum: 224ade448deec3f98ba1b9365131d5c5 (MD5) Previous issue date: 1989 / Resumo: Atualmente, a principal dificuldade encontrada na cirurgia vascular é a avaliação do desempenho hemodinâmico da período intra-operatório. O sistema descrito neste trabalho faz uso de um equipamento Doppler direcional de ondas contínuas, de um microcomputador e de um monitor cardíaco. O transdutor ultra-sônico é fixo sobre as artérias e/ou próteses usando um dispositivo especial, tambem desenvolvido neste trabalho, para avaliação local do fluxo sanguíneo. Um microcomputador de 16 bits conectado ao sistema ultra-sônico digitaliza, armazena numa memória circular e processa uma série de 12 ciclos representativos escolhidos no vídeo através do teclado, usando subrotinas também desenvolvidas neste trabalho. Estes sinais são somados, tendo o pico do complexo GRS como sinalizador para obtenção do resultado médio. Um software especial foi desenvolvido para detectar o pico do GRS e a curva calcular um total de sete parâmetros. Após a promediação,a curva resultante e os parâmetros calculados são mostrados no vídeo. Relatório impresso e arquivos em discos flexíveis podem ser obtidos. Os testes experimentais mostram que o sistema detecta distúrbios do fluxo sanguíneo nas anastomoses, e estes resultados podem auxiliar significantemente o cirurgião as cirurgias de revascularização / Abstract: At present, the main difficulty found in vascular surgery is the evaluation of intra-operatory haemodinamic performance of vascular prosthesis. The proposed system uses a continuous wave Doppler directional ultrasonic equipment, a microcomputer and a cardiac monitor . The ultrasonic transducer is fixed on arteries and/or prosthesis using a special device, developed in this work, for on site blood flow evaluation. A 16-bit microcomputer connected to the ultrasonic system digitalizes, stores in a circular memory and processes a series of twelve mainly cycles chosen on screen by means of the keyboard, using functions also developed here. The signals are summed, having the peak of the GRS complex as trigger, to obtain the averaged result. A special software was developed to detect the GRS peak and calculate seven parameters. All the results, including the averaged curve are shown on the screen. Printed reports and files on floppy disk are possible. The results have shown that the system can help the surgeon in the evaluation of intra-operatory anastomosis blood flow performance / Mestrado / Mestre em Engenharia Elétrica
34

Geração de pulsos ultracurtos de radiação laser

Cruz, Carlos Henrique de Brito, 1956- 24 July 1983 (has links)
Orientador: Artemio Scalabrin / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T13:50:05Z (GMT). No. of bitstreams: 1 Cruz_CarlosHenriquedeBrito_D.pdf: 3849023 bytes, checksum: 200d310d8d0e9bd68b6cdca12909730d (MD5) Previous issue date: 1983 / Resumo: Neste trabalho são apresentados novas técnicas desenvolvidas para produção de pulsos de duração ultracurta ( < 1 ns ) com lasers. A técnica de auto injeção aplicada aos lasers de NdYAG e de corante bombeado com lâmpada permitiu a obtenção de pulsos sincronizáveis, de baixo "jitter" ( < 1ns ) e duração tão curto como 200 ps, atingindo potência de pico de 100 MW. Com uso de compressão não linear com absorvedor saturável pulsos com 8 ps e 1 GW foram obtidos num laser a NdYAG, novamente em forma sincronizável e estável. No laser de corante bombeado com laser de Argônio obtivemos pulsos com 40 ps, sincronizáveis de 5700 Å a 6200 Å com potência média de 20 mW e uma taxa de repetição de 110MHz. Com o uso de uma cavidade em anel e em regime de acoplamento passivo de modos este laser forneceu pulsos com duração abaixo de 170 femtosegundos e potência de pico de 1,4 kW, em modo extraordinariamente estável. Com o laser de CO2 de descarga elétrica transversal, o uso do acoplamento passivo permitiu a obtenção de pulsos com duração de 1 ns e foi desenvolvido o projeto de um sistema para obtenção de pulsos de picosegundos baseado numa chave a semicondutor controlado por luz. Para cada um dos sistemas novos desenvolvidos foi elaborado um modelo teórico que permitisse otimizar o funcionamento e avaçar o entendimento de fenômenos envolvendo pulsos laser ultracurtos / Abstract: In this work we describe new techniques which have been developed for the generation of ultrashort duration laser pulses. The self injection technique used in conjunction with the NdYAG and flashpumped dye lasers allowed the obtention of subnanosecond pulses with very good synchronizability and jitter characteristics. Pulses with 200 ps and 100 MW peak power were obtained. The use of nonlinear pulse compression with an intracavity saturable absorber led to the generation of 8 ps, 1 GW pulses with the NdYAG laser, with much better performance than passive mode locking. With the argon laser pumped dye laser we generated 40 ps pulses tunable between 5700 Å and 6200 Å at an average power of 20 mW and repetition rate of 110 MHz. In the ring configuration with a saturable absorver this laser produced pulses shorter than 170 femtoseconds and peak power of 1.4 kW. With the transverse discharge CO2 laser we use passive mode locking to obtain 1ns pulses and designed an injection mode locking system based on a laser controlled semicondutor light gate capable of generating pulses as short as 50 ps in the infrared. For each of the new systems we developed a theoretical mode which allowed performance optimization and an improvement in the understanding of ultrashort laser pulse phenomena / Doutorado / Física / Doutor em Ciências
35

Influencia do ultra-som na permeação cutanea da cafeina : estudo em fragmentos de pele e em adipocitos isolados de suinos

Pires-de-Campos, Maria Silvia Mariani 29 July 2004 (has links)
Orientadores: Dora Maria Grassi-Kassisse e Regina Celia Spadari-Bratfisch / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-04T03:00:09Z (GMT). No. of bitstreams: 1 Pires-de-Campos_MariaSilviaMariani_M.pdf: 487373 bytes, checksum: 2c340fe6e22950d82af4aa99e2140fa3 (MD5) Previous issue date: 2004 / Resumo: O ultra-som tem sido usado extensivamente nas últimas décadas para terapias físicas e como promotor de penetração cutânea de fármacos. O uso do ultra-som como facilitador de absorção cutânea é conhecido por fonoforese ou sonoforese. Os objetivos do presente trabalho foram analisar o efeito do ultra-som sobre a permeação cutânea da cafeína aplicada localmente, sobre a pele, e analisar a resposta lipolítica de adipócitos isolados de suínos após este tratamento. A cafeína inibe a fosfodiesterase, que degrada o AMPc, este efeito resulta em uma potencialização do efeito de agonistas lipolíticos. Tem sido relatado também que a cafeína tem um papel em inibir o receptor de adenosina, inibindo então seu efeito anti-lipolítico, como conseqüência, o uso da cafeína leva a facilitação da lipólise. Para este estudo, foram utilizados suínos machos Landrace x Large White com 35 dias e peso aproximado de 15 kg. Após tricotomia da região dorsal, os animais foram submetidos aos seguintes tratamentos durante quinze dias: Gel; cafeína (5%), CAF; ultra-som, US; ultra-som + cafeína (5%), US + CAF. Uma 5ª área foi submetida a infiltração intradérmica (mesoterapia) de cafeína (2%). Uma 6ª área serviu como controle e não foi submetida a tratamento. Ao final dos diferentes tratamentos os animais foram sacrificados e fragmentos de pele das diferentes áreas foram retirados para análise histológica e 15 g de tecido adiposo foi utilizado para isolamento de adipócitos. Nos adipócitos isolados foram analisadas a produção de glicerol frente ao estímulo do agonista ?-adrenérgico não seletivo, a isoprenalina. A mesoterapia mostrou-se eficaz na redução da espessura da hipoderme. O ultra-som mostrou-se importante acentuador da permeação cutânea à cafeína, evidenciado tanto pelo estudo histológico, onde foram observadas significativas alterações morfológicas do tecido adiposo bem como pelo aumento da resposta lipolítica máxima, em adipócitos isolados, sem, contudo alterar a sensibilidade dos receptores adrenérgicos. Também realizamos análise de permeação cutânea da cafeína in vitro através de células de difusão vertical utilizando pele de suínos machos Landrace x Large White com 50 dias e os resultados obtidos também demonstraram uma acentuada permeação da cafeína quando associada ao ultra-som terapêutico / Abstract: The ultrasound has been extensively used in the last decades for physical therapies and as promoter of cutaneous permeation of drugs. The use of ultrasound as facilitator of cutaneous absorption is knows for phonophoresis or sonophoresis. The aim of present research were to analyze the effect of ultrasound on the cutaneous permeation of caffeine applied locally on the skin, and to analyze the lipolytic response of isolated adipocyte of swine after this treatment. The caffeine inhibits the cAMP-phosphodiesterase which hydrolyzes cAMP, this effect result in an increase of the effect of lipolytic agonists. However, has been also mentioned that the caffeine is able to inhibit the adenosine receptors, inhibiting thus effect antilipolytic, as consequence the use of caffeine leads of the facilitation of the lipolysis. For this study, male swine were used Landrace x Large White with 35 days and approximate weight of 15 kg. After trichotomy of the dorsal area the animals were submitted to the following treatments, for fifteen days: gel; caffeine (5%); ultrasound; ultrasound + caffeine (5%). A 5th area was submitted the intradermic infiltration (mesotherapy) of caffeine (2%). A 6th area served as control and it was not submitted to treatment. At the end of the different treatments the animals were sacrificed and fragments of skin of the different areas were used for histological analysis and 15 g of adipose tissue for adipocytes isolation. The lipolytic activity was analyzed in the isolated adipocytes. The adipocytes were incubated with agonist ?-adrenergic (isoprenaline) and the glycerol production were measured. The mesotherapy was shown effective in the reduction of the thickness of the hypodermis. The ultrasound was shown important accentuator of the cutaneous permeation to the caffeine, evidenced so much by the histological study, where it was observed significant morphologic alterations of the adipose tissue as well as for the increase of the maximal lipolytic response, in adipocytes isolated, without, however to alter the sensibility of the ? adrenergic receptors. Also accomplished analysis of cutaneous permeation of the caffeine in vitro through cells of vertical diffusion using skin of male swine Landrace x Large White with 50 days old and the results obtained also demonstrated an accentuated permeation of the caffeine when associated to the therapeutic ultrasound / Mestrado / Fisiologia / Doutor em Biologia Funcional e Molecular
36

Élaboration de matériaux multicouches par « laminage cumulé contrôlé » / Elaboration of multilayers by controlled accumulative roll bonding

Anghelus, Adrian 07 December 2012 (has links)
Cette étude porte sur la faisabilité de l’élaboration de matériaux multicouches à grains ultrafins par un procédé original de métallurgie douce : le laminage cumulé contrôlé. Les multicouches à base d’aluminium sont renforcés par des alliages de compositions Al-Ni-Sm pris dans des états amorphe ou cristallisés. Cette combinaison à ce jour inédite est originale compte tenu de la différence marquée de comportement mécanique et de mécanisme de déformation des constituants. Les paramètres du procédé sont d’abord définis à partir de la caractérisation de la stabilité microstructurale des constituants et de leur comportement mécanique. Plusieurs types de traitement thermique et mécanique, ainsi que différents nombres de couches ont été testés afin d’optimiser la microstructure et par tant l’aptitude à la mise en forme. Les transformations de phases (recristallisation dynamique ou non de l’aluminium, changements de phases au sein des alliages Al-Ni-Sm…) ont été analysées par diffractométrie X, microscopies et calorimétrie différentielle. Parmi les principaux résultats, la cristallisation du verre métallique induite par déformation est démontrée. En relation avec la modification de propriétés mécaniques induite par le changement de microstructure des renforts, les multicouches élaborées à partir de renforts à l’état cristallin sont plus malléables que celles obtenues au moyen d’alliages à l’état amorphe. La différence est reliée à la fois à la morphologie des débris et à l’accommodation des déformations au niveau des interfaces matrice/renfort. Au stade actuel du travail, un multimatériau a été synthétisé à partir de 216 couches d’aluminium et de 180 feuilles de renfort à l’état cristallin. Ce matériau à grains ultrafins présente encore une distribution non uniforme de fragments de renforts. / This study of feasibility deals with the development of ultrafine grained (UFG) multilayers by an original process i.e. controlled accumulative roll bonding. Aluminium based multilayers are reinforced by Al-Ni-Sm alloys taken either in the amorphous or crystallized state. This association of materials is particularly interesting according to the significant difference of mechanical behavior and mechanism of deformation of both constituents. The definition of the process parameters arises from the study of both the stability and the mechanical behaviour of the constituents. Numerous thermal and mechanical treatments as well as various numbers of stacked layers have been considered in order to optimize the microstructure and therefore workability of the multilayers. The phase transformations (dynamical or static recrystallization of Al, crystallization of amorphous alloys…) have been investigated by X-ray diffractometry, various kinds of microscopy and differential scanning calorimetry. Among the main results, the crystallization of the metallic glass due to deformation has been proved. Due to the modification of the mechanical properties induced by the change of microstructure of the reinforcements, the multilayers bearing crystalline reinforcements are more deformable than those containing amorphous alloys. The difference is explained by the morphology of the fragments of reinforcements as well as by the accommodation of deformation at their interfaces. Finally, a multimaterial has been prepared from 216 Al layers and 180 layers of crystalline reinforcements. This UFG material presents a heterogeneous distribution of reinforcements.
37

Geração de pulsos laser com duração de fentosegundos

Jacobovitz, Gloria Regina 05 November 1985 (has links)
Orientador: Carlos Henrique de Brito Cruz / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-17T17:35:34Z (GMT). No. of bitstreams: 1 Jacobovitz_GloriaRegina_M.pdf: 3777213 bytes, checksum: d9432a7def7c3dfe927ccc39d250323f (MD5) Previous issue date: 1985 / Resumo: Neste trabalho foi estudado o laser de corante em regime de colisão de pulsos contrapropagantes gerando pulsos de fentosegundos. A fim de se obter pulsos com menores durações, foi analisada a influencia da variação dos parâmetros do laser como por exemplo, potência de bombeio, concentração e posição do absorvedor. Dessa maneira foram obtidos pulsos de até 47 fs. O laser produz pulsos a uma repetição de 100 MHz e a potência média de saída é 30 mW e a potência de pico é 6,4 kW. Um modelo teórico foi desenvolvido para explicar os resultados experimentais. Foi mostrado então que o efeito conjugado das varreduras de frequências devido à dispersão e à automodulação de fase no absorvedor saturável e no solvente tem um importante papel no encurtamento do pulso / Abstract: In this work we have studied the colliding pulse mode locked dye laser, which is able to generate femtosecond duration laser pulses. We have obtained pulses with a duration as short as 47 femtoseconds. To obtain these extremely short pulses we have optimized the laser performance, analizing the effect of the pump power, dye concentration and cavity geometry on the duration and stability of the generated pulses. Under typical conditions our laser produces pulses shorter than 100 fs at a repetition rate of 100 MHz, at an average power of 30 mW and with peak pulse power as high as 6.4 kW. A model was suggested to justify the very strong compression rate that we have obtained. This model is based on the balancing of the group velocity dispersion of the laser cavity with the frequency sweep that is generated on the pulse when it interacts with the saturable absorber and its solvent / Mestrado / Física / Mestre em Física
38

Ultra-Violet Transcription Unit Mapping of Adenovirus Type 2

Girvitz, Sheldon 03 1900 (has links)
At late times during the infection of human KB cells with Adenovirus type 2 (Ad 2), the ultraviolet (uv) sensitivity of transcription was assayed by DNA-RNA hybridization across the length of the genome. Assuming that the majority of the nuclear transcripts at this time of infection are read from the rightward transcribing DNA strand, the resulting plot of the surviving fraction of viral transcription vs. genome position indicates two transcription units are responsible for the transcription from selected DNA restriction fragments of the genome were also obtained. The uv inactivation cross sections generated from such curves identified a long, uv sensitive transcript originating from the major late promoter at approximately 17 map units, and a shorter, less uv sensitive from approximately 63 map units on the genome. The shorter transcription unit accounts for about one third to a half of the viral nuclear RNA synthesized from the right hand 30 to 40% of the genome. The majority of the late viral nuclear transcripts, however, originated at approximately 17 map units and terminated at around 60-70 map units. Similar experiments examining the uv sensitivity of cytoplasmic poly A RNA production at various sites across the length of the genome are consistent with two rightward transcribing transcription units expressed during late Ad 2 infection. The transcriptional organization of late Ad 2 gene expression was also approached through uv transcription unit mapping experiments by examining the uv sensitivities of the synthesis of late Ad 2 proteins for which the approximate gene locations are known. The effect of uv on Ad 2 nuclear transcription was also reflected at the polypeptide level indicating two transcription units are responsible for the synthesis of mRNA coding for late viral proteins. The differential radiosensitivities of late protein synthesis confirmed the relative gene positions on the Ad 2 genome. / Thesis / Master of Science (MS)
39

Estudo comparativo de sistemas a base de lasers, leds e ultra-som (US) de baixa intensidade no reparo tecidual em tendão calcâneo / Comparative study of Laser, LED and US systems of low intensity applied to tendon healing

Bastos, Jessica Lucia Neves 05 August 2008 (has links)
Um dos recursos mais utilizados no processo de reparo de lesões tendíneas é o laser que demonstrou ter resultados satisfatórios quando se buscam efeitos antiinflamatório e cicatrizante. No entanto, por requerer uma tecnologia de alto custo, um outro tipo de fototerapia vem sendo buscado, como o diodo emissor de luz, LED. Porém, o número de pesquisas realizadas para a determinação segura de seus efeitos terapêuticos ainda é muito pequeno, inviabilizando uma proposta de protocolo para adoção do LED. Um outro recurso também utilizado durante a reabilitação de lesões tendíneas, é o ultra-som pulsado de baixa intensidade (LIPUS). Trabalhos realizados até o momento mostram alterações satisfatórias quanto à deposição e alinhamento das fibras de colágeno. Este estudo objetiva testar comparativamente a eficácia da aplicação de LEDs 630 nm e 830 nm em relação à terapia laser de baixa intensidade (LILT), com laser de 685 nm e 830 nm, e à terapia com LIPUS em tendão calcâneo parcialmente lesado. Foram utilizados 56 ratos Wistar, submetidos à lesão mecânica parcial do tendão calcâneo. A análise da evolução do processo foi realizada através da microscopia de polarização. Os resultados mostraram uma real eficácia dos tratamentos com LEDs e lasers, e uma ineficácia do tratamento à base de US. Nosso estudo sugere que uma boa organização e um bom alinhamento das fibras de colágeno são conseguidos no processo de reparo de lesões tendíneas através de aplicações à base de LED 880 nm e laser 630 nm, os quais se mostraram mais eficazes. No entanto, outras pesquisas na área se fazem necessárias para uma determinação segura e eficaz dos protocolos de tratamento utilizando essa modalidade de fototerapia. / Laser is one of the most effective resources of treatment for tendinous injury when anti-inflammatory and cicatrizing effects are wanted. However, it is considered an expensive treatment and so, an alternative and cheaper light therapy as effective as it has been searched and the light emitting diodes, LEDs, are a promising candidate for it. Results from the studies already done have been useful to predict the possible effects of LED on the injured tissues, but are not enough to establish a treatment protocol that guarantees its recommendation as a substitute therapeutic tool for tendinous injury treatment. Another promising resource for tendinous injury healing is the ultra-sound of low intensity (LIPUS). Studies done until the present moment have shown satisfactory results when deposition and alignments of collagens fibers are wanted. The aim of this study was to compare the effects of laser, light emitting diodes (LEDs) and ultra-sound of low intensity on the treatment of Achilles tendon of albino rats, Wistar lineage, exposed to mechanical trauma. The experimental model consisted of a partial mechanical lesion of the right Achilles tendon of 56 rats, which were divided in 6 groups, 5 with 10 animals and one, the control group, with 6. One hour after the lesion, the injured animals received the respective applications of laser, LED or US, and the same procedure was repeated each 24 h. The healing process and the deposition were evaluated by analyze of the alignment of collagens fibers through polarization microscopy. The results showed a real efficiency of treatments based on LEDs and lasers, but the treatment based on US was inefficient. Applications of laser at 830 and LED 880 nm were more efficient when the aim is a good organization and alignment of the collagen fibers on tendon healing. However more research is needed for a safety and more efficient determination of a protocol.
40

"Ultra-sonografia recurso imaginológico aplicado à odontologia" / Ultrasonography – imaginologic resource applied to dentistry Odontologia.

Ferreira, Thásia Luiz Dias 01 April 2005 (has links)
O ultra-som é um recurso imaginológico relativamente recente, que foi desenvolvido primeiramente para utilização submarina, e só depois fundamentada na área da Saúde. Esse sistema utiliza ondas ultra-sônicas, que são produzidas em um dispositivo denominado transdutor, responsável também por enviá-las ao tecido a ser avaliado; é também o responsável por receber os ecos sonoros que são refletidos pelas estruturas que possuem diferentes impedâncias acústicas, obtendo-se assim os resultados. As primeiras gerações de US (modo-A) utilizavam um sistema numérico pouco atrativo para a interpretação dos resultados. Somente com o advento do modo-B, que apresenta imagens tomográficas, o ultra-som começou a se tornar um método imaginológico mais utilizado. Com a evolução dos aparelhos, a técnica permitia que as imagens fossem processadas a uma velocidade suficientemente rápida para deixar passar a percepção de movimento. É possível por meio do Doppler colorido, caracterizado pela associação das imagens em movimento em tempo real, mapear o fluxo vascular. Pela revisão da literatura, concluímos que: o ultra-som é um exame imaginológico recente; é um método auxiliar na elaboração do diagnóstico, não invasivo, indolor e sem nenhum efeito deletério conhecido até os dias atuais; é um exame imaginológico com alta especificidade para tecidos moles; é um recurso capaz de detectar, delimitar 9 (inclusive em profundidade) e avaliar o conteúdo interno, tanto na normalidade quanto nas alterações do complexo dento-maxilo-cervico-facial; a interpretação pode ser feita em tempo real, sendo passível de repetição, sempre que necessário; é operador-dependente e tem ampla aplicação nas diferentes Especialidades Odontológicas. / The Ultrasound (US) is a relatively recent imaginologic resource that was first developed for submarine use, and then applied in the Health area. This system makes use of ultrasonic waves, produced in a device called transducer, which is also responsible for sending them to the tissue to be evaluated. The transducer is responsible for receiving the eco sounds that are reflected by structures that possess different acoustic impedances, thus obtaining results. The first generations of US (A-mode) used a numerical system that was not very attractive for results interpretation. Only with the discovery of the B-mode, which presents tomographic images, the ultrasound started to become a more utilized method. As devices evolved, the technique allowed images to be processed in such a high velocity that would let the perception of movement pass. It is possible to map the vascular flux in real time by using Coloured Doppler, characterized by the association of moving images. By literature review, we concluded that: the ultrasound is a recent imaginologic exam; it is a non-invasive, painless, auxiliary diagnostic method and has shown no known side effects until the present date; it is a high-specificity imaginologic exam for soft tissues; it is a resource capable to detect, delimitate (including in depth), and evaluate the internal content in normality as much as in dento-maxilo-cervico-facial alterations; the interpretation can be made in real time, and repetition is always 11 possible when necessary; it is operator-dependent and has a wide application in different odontological specialities.

Page generated in 0.0561 seconds