• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

SPEM, sistema pulso-eco microcontrolado para geração e medição de campos ultra-sonicos

Maia, Joaquim Miguel 23 February 1995 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T22:25:02Z (GMT). No. of bitstreams: 1 Maia_JoaquimMiguel_M.pdf: 7879185 bytes, checksum: d81c83b96f5059062de96632b0410c74 (MD5) Previous issue date: 1995 / Resumo: Para uma melhor compreensão e confiabilidade no processamento das informações obtidas pela radiação ultra-sônica, torna-se muito importante o entendimento dos princípios básicos da geração de ondas ultra-sônicas bem como sua interação e propagação através dos mais diversos meios. Isto pode ser parcialmente alcançado através da utilização de equipamentos adequados e um amplo conhecimento das suas características de operação. Tendo como objetivo a medição e o estudo de características ultra-sônicas de diferentes materiais, foi desenvolvido um Sistema Pulso-Eco Microcontrolado (SPEM) para geração e recepção de sinais de radiofreqüência (RF) na faixa do ultra-som para diagnóstico médico. O "hardware" do sistema desenvolvido é formado por circuitos de transmissão, circuitos de recepção, circuitos de controle e de interfaceamento. Os circuitos de interfaceamento e controle foram desenvolvidos utilizando-se o microcontrolador MC68HCII-Al da Motorola, "drivers" e circuitos de apoio para implementar a Interface Padrão IEEE-488 ("General Purpose Interface Bus" - GPIB). O SPEM pode ser operado tanto por controle remoto, via interface GPIB, como por controle local via teclado e chaves no painel frontal do mesmo. O "software" para controle local foi escrito na linguagem Assembly do MC68HCll e o "software" para controle remoto via interface GPIB foi desenvolvido utilizando-se a linguagem de programação C e é executado em um computador compatível com o IBM PC, equipado com uma interface da Hewlett-Packard modelo HPIB 82335A. O microcomputador opera como controlado r do barramento GPIB. Os circuitos de transmissão são capazes de gerar pulsos com largura de 330 ns e amplitude controlada entre 15 V e 200 V ou pulsos de 200 ns, 300 ns, 400 ns, 500 ns, 600 ns e 700 ns com amplitude controlada entre 2 V e 28.4 V. Os circuitos de recepção podem amplificar sinais de RF com freqüências entre 10 kHz e 10 MHz em 25 ganhos distribuídos na faixa entre 0.6 V/V e 3730 V/V (-4.4 dB a 71.5 dB). Os testes para avaliação de desempenho do sistema foram realizados no Laboratório de Ultra-som do Centro de Engenharia Biomédica da Unicamp (LUS-CEB) com a geração e recepção de ondas ultra-sônicas em meio líquido, utilizando-se um transdutor circular de 1 MHz colocado em contato com um cilindro de alumínio. Estes testes mostraram que o equipamento pode ser utilizado para fins de pesquisa em laboratório / Abstract: In order to obtain more reliability in the processing of information obtained by ultrasound radiation, it is very important to understand the basic principIes of ultrasound wave generation, interaction with and propagation through different media. This can be partially achieved with suitable equipments and a good knowledge of its working conditions. In an effort to measure and study ultrasonic features of different materiaIs, we have developed a Pulse-Echo Microcontrolled System (SPEM) for generation and reception of RF signals in the range ofultrasound medical diagnosis. The hardware consists oftransmission, reception, control and interfacing circuits. The control and interfacing circuits were developed with a Motorola MC68HCII-Al microcontroller and proper circuitry to implement the IEEE Standard 488 (General Purpose Interface Bus - GPIB). The SPEM is fully controlled via remote mode through the GPIB interface, and permits local control with proper keys in the front pane!. Special software has been developed Ín C-language to run in an IBM-PC compatible microcomputer, working as GPIB controller and equiped with a HPIB 82335A interface model of Hewlet-Packard. The SPEM control software has been written in MC68HC11 assembly language. The transmitting circuit emits pulses 330 ns wide with an amplitude that may be controlled from 15 V to 200 V or pulses 200 ns, 300 ns, 400 ns, 500 ns, 600 ns and 700 ns wide with an amplitude controlled from 2 V to 28.4 V. The receiving circuit amplifies RF signals in the range of 10 kHz to 10 MHz from 0.6 V/V to 3730 V/V (-4.4 dB to 71.5 dB) in 25 steps. The system was tested with a 1 MHz transducer facing an aluminun rod, both immersed in water. Ultrasound waves have been generated and received by the system which has presented good performance. The results have shown that the equipment may be used for research purposes in the Ultrasound Laboratory of the Centre for Biomedical Engineering at Unicam / Mestrado / Automação / Mestre em Engenharia Elétrica
12

"Avaliação de retropreparos confecionados por pontas de ultra-som lisas, diamantadas e despolidas" / Evaluation of retropreparations carried out with smooth ultrasound, diamond coated and no polished tips

Salzano, Karina 15 February 2006 (has links)
Diante das vantagens do uso do ultra-som na confecção de cavidades retrógradas, o presente estudo avaliou pontas lisas, diamantadas e despolidas quanto ao tempo usado para confecção das cavidades, presença de sujidade e infiltração do corante rodamina a 0,2%. Após os tratamentos endodônticos e apicectomias dos trinta e quatro dentes uniradiculares estudados, estes foram divididos em três grupos de 10; de acordo com a ponta usada para o retropreparo. A confecção das cavidades retrógradas consistiu de duas fases: fase 1 (a ponta de ultra-som deveria atingir 3mm de profundidade, não visualização de sujidade a “olho nu", preparo com características de classe I), e fase 2 (uso da ponta de ultra -som correspondente a cada grupo por mais 40 segundos). Ao final de cada fase, os espécimes foram avaliados sob microscópio óptico com aumento de 20X e fotografados. Quatro examinadores analisaram a presença de sujidade nas superfícies retropreparadas. O tempo gasto para a confecção da fase 1 foi anotado. Em seguida, todos os espécimes submeteram-se a retrobturação com MTA. Passado período de 72 horas, foram imersos em solução de rodamina a 0,2% e clivados após 24 horas. A hemi-parte que continha maior infiltração de cada espécime, foi a considerada. Os resultados mostraram que as pontas despolidas necessitam de menos tempo para confecção de cavidades retrógradas. Após mais 40 segundos de preparo (fase 2), houve diminuição na quantidade de sujidade, em todos os grupos, não havendo diferença estatística significante entre os grupos. Em relação a infiltração do corante rodamina a 0,2%, os resultados mostraram não haver diferença estatística significante, quando da comparação entre os preparos confeccionados por pontas lisas, diamantadas e despolidas e retrobturados pelo MTA. Concluímos, portanto, que o tipo de ponta de ultra-som influencia no tempo de preparo, apesar de não exercer influência na infiltração do MTA. Vale ressaltar que a presença de sujidade é intensamente minimizada quando da complementação dos preparos por mais 40 segundos. / Given the advantages of the use of ultrasound in the preparation of retrograde cavities, the present study evaluated the smooth, diamond -coated and use of no polished tips regarding the time required for the preparation of cavities, the presence of dirt and the penetration of the 0,2% rhodamine dye solution. After the apicectomy and endodontic treatment of the thirty-four single -rooted teeth studied, we divided them into 3 groups of 10 according to the tip used in the rootend preparation. Four roots were used as positive and negative controls. The preparation of the retrograde cavities consisted of two phases: phase 1 (the ultrasound tip should reach 3mm of depth; dirt should not be spotted by the naked eye; preparation with class I characteristics), and phase 2 (use of the ultrasound tip corresponding to each group for more than 40 seconds). At the end of each phase, the specimens were evaluated under an optical microscope that enhanced them 20X, and were then photographed. Four examiners analyzed the presence of dirt in the root-end preparation surfaces. The time spent in phase 1 was recorded. All the specimens were then root-end filling with MTA. After 72 hours, they were submerged in a 0,2% rhodamine solution and cleaved after 24 hours. We then analyzed the hemi-part that contained the highest penetration. The results showed that the no polished tips require shorter time in the preparation of retrograde cavities. After over 40 seconds of preparation (phase 2), there was a reduction in the amount of dirt in all the groups studied, with no signify cant differences between the groups. As regards the penetration of the rhodamine dye at 0,2%, the results did not show statistically significant differences as regards preparations with smooth, diamondcoated and no polished tips, and root-end filling with MTA. Therefore , we concluded that the type of ultrasound tip influences the preparation time, even though it has no influence on the penetration of MTA. It is important to stress that the presence of dirt is highly minimized when the preparation is complemented by 40 more seconds.
13

Desempenho e qualidade de carcaça em ovinos cruzados no Distrito Federal. / Performace and carcass quality in croossbred sheep in the Federal District

Landim, Aline Vieira 02 December 2005 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, 2010. / Submitted by samara castro (sammy_roberta7@hotmail.com) on 2010-10-01T22:35:08Z No. of bitstreams: 1 2005-Aline Vieira Landim.pdf: 2458673 bytes, checksum: bca5ee7bf72f5370d81891b13109ecae (MD5) / Approved for entry into archive by Lucila Saraiva(lucilasaraiva1@gmail.com) on 2010-10-07T00:55:07Z (GMT) No. of bitstreams: 1 2005-Aline Vieira Landim.pdf: 2458673 bytes, checksum: bca5ee7bf72f5370d81891b13109ecae (MD5) / Made available in DSpace on 2010-10-07T00:55:07Z (GMT). No. of bitstreams: 1 2005-Aline Vieira Landim.pdf: 2458673 bytes, checksum: bca5ee7bf72f5370d81891b13109ecae (MD5) / Foram estudadas as características de carcaça de 48 ovinos machos e inteiros, oriundos de quatro grupos genéticos diferentes, sendo 27 animais da raça Santa Inês, 10 da raça Bergamácia, 5 oriundos do cruzamento do Texel com ovelhas Santa Inês e 6 animais provenientes do cruzamento de um reprodutor Bergamácia com ovelhas Santa Inês. Os animais foram mantidos no pasto (Grupo 1) e em semiconfinamento (Grupo 2). Foram analisadas as características sobre desempenho ponderal, avaliação ultra-sonográfica “in vivo”, medidas morfométricas e características quantitativas da carcaça de ovinos. Os dados foram analisados usando o procedimento GLM (Análise de variância), CORR (Correlação), PRINCOMP (Componentes principais), REG (Regressão) e teste de médias (Tukey 5%) do programa estatístico SAS (Statistical Analysis System). Os animais que apresentaram pesos mais baixos, tendem a possuir menores valores nas características ultra-sonográficas., verificado através das correlações de baixa a média. Verificou-se que a correlação dos cortes comerciais com os pesos e rendimentos de carcaça quente e fria, respectivamente, foram de média a alta e positiva. Em geral a idade ao abate teve correlações baixas com as características da carcaça. Os componentes principais mostraram que os animais que apresentaram alto peso de abate tendem a obter altos pesos para as partes da carcaça. Os animais cruzados apresentaram em geral as maiores médias relacionadas às características analisadas. _________________________________________________________________________________ ABSTRACT / Performance and carcass traits were studied on 48 male entire sheep from four genetic groups with 27 animals Santa Inês, 10 Bergamasca, 5 from a cross with Texel sire and Santa Inês dams and 6 from a cross with a Bergamasca sire and Santa Inês dams. Animals were reared at pasture (Group 1) and in semi-confinement (group 2). Data collected included growth traits, “in vivo” ultrasound measurements, morphological measurements and carcass quality traits.Data were analyzed using GLM procedures (Variance analysis), CORR (Correlation), PRINCOMP (Principal Component), REG (Regression) and means compared using Tukey test at 5% in the SAS ® program.Lighter animals tended to have low ultrasound measures. The correaltions between weights, output and commercial cuts was in general high to medium. Age at slaughter had low correlations with carcass traits. Principal components showed that heavier animals at slaughter had higher carcass cut weights. The crossed animals had in general presented the related average greaters to the analyzed characteristics.
14

"Avaliação de retropreparos confecionados por pontas de ultra-som lisas, diamantadas e despolidas" / Evaluation of retropreparations carried out with smooth ultrasound, diamond coated and no polished tips

Karina Salzano 15 February 2006 (has links)
Diante das vantagens do uso do ultra-som na confecção de cavidades retrógradas, o presente estudo avaliou pontas lisas, diamantadas e despolidas quanto ao tempo usado para confecção das cavidades, presença de sujidade e infiltração do corante rodamina a 0,2%. Após os tratamentos endodônticos e apicectomias dos trinta e quatro dentes uniradiculares estudados, estes foram divididos em três grupos de 10; de acordo com a ponta usada para o retropreparo. A confecção das cavidades retrógradas consistiu de duas fases: fase 1 (a ponta de ultra-som deveria atingir 3mm de profundidade, não visualização de sujidade a “olho nu”, preparo com características de classe I), e fase 2 (uso da ponta de ultra -som correspondente a cada grupo por mais 40 segundos). Ao final de cada fase, os espécimes foram avaliados sob microscópio óptico com aumento de 20X e fotografados. Quatro examinadores analisaram a presença de sujidade nas superfícies retropreparadas. O tempo gasto para a confecção da fase 1 foi anotado. Em seguida, todos os espécimes submeteram-se a retrobturação com MTA. Passado período de 72 horas, foram imersos em solução de rodamina a 0,2% e clivados após 24 horas. A hemi-parte que continha maior infiltração de cada espécime, foi a considerada. Os resultados mostraram que as pontas despolidas necessitam de menos tempo para confecção de cavidades retrógradas. Após mais 40 segundos de preparo (fase 2), houve diminuição na quantidade de sujidade, em todos os grupos, não havendo diferença estatística significante entre os grupos. Em relação a infiltração do corante rodamina a 0,2%, os resultados mostraram não haver diferença estatística significante, quando da comparação entre os preparos confeccionados por pontas lisas, diamantadas e despolidas e retrobturados pelo MTA. Concluímos, portanto, que o tipo de ponta de ultra-som influencia no tempo de preparo, apesar de não exercer influência na infiltração do MTA. Vale ressaltar que a presença de sujidade é intensamente minimizada quando da complementação dos preparos por mais 40 segundos. / Given the advantages of the use of ultrasound in the preparation of retrograde cavities, the present study evaluated the smooth, diamond -coated and use of no polished tips regarding the time required for the preparation of cavities, the presence of dirt and the penetration of the 0,2% rhodamine dye solution. After the apicectomy and endodontic treatment of the thirty-four single -rooted teeth studied, we divided them into 3 groups of 10 according to the tip used in the rootend preparation. Four roots were used as positive and negative controls. The preparation of the retrograde cavities consisted of two phases: phase 1 (the ultrasound tip should reach 3mm of depth; dirt should not be spotted by the naked eye; preparation with class I characteristics), and phase 2 (use of the ultrasound tip corresponding to each group for more than 40 seconds). At the end of each phase, the specimens were evaluated under an optical microscope that enhanced them 20X, and were then photographed. Four examiners analyzed the presence of dirt in the root-end preparation surfaces. The time spent in phase 1 was recorded. All the specimens were then root-end filling with MTA. After 72 hours, they were submerged in a 0,2% rhodamine solution and cleaved after 24 hours. We then analyzed the hemi-part that contained the highest penetration. The results showed that the no polished tips require shorter time in the preparation of retrograde cavities. After over 40 seconds of preparation (phase 2), there was a reduction in the amount of dirt in all the groups studied, with no signify cant differences between the groups. As regards the penetration of the rhodamine dye at 0,2%, the results did not show statistically significant differences as regards preparations with smooth, diamondcoated and no polished tips, and root-end filling with MTA. Therefore , we concluded that the type of ultrasound tip influences the preparation time, even though it has no influence on the penetration of MTA. It is important to stress that the presence of dirt is highly minimized when the preparation is complemented by 40 more seconds.
15

Avaliação ultra-sonografica ovariana e estado menopausal

Giacobbe, Marcelo 03 August 2018 (has links)
Orientador : Aarão Mendes Pinto-Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-03T04:44:18Z (GMT). No. of bitstreams: 1 Giacobbe_Marcelo_D.pdf: 4742895 bytes, checksum: d9571c92d1996996ed42b237c7f14f4a (MD5) Previous issue date: 2003 / Doutorado
16

Contribuição ao estudo da avaliação da idade gestatoria pela medida ecografica do diametro biparietal fetal : estudo em gestantes normais

Sarian, Mariza Zanatta, 1941- 16 July 2018 (has links)
Orientador : Jose Aristodemo Pinotti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-16T06:44:19Z (GMT). No. of bitstreams: 1 Sarian_MarizaZanatta_D.pdf: 1800225 bytes, checksum: d08007859df9db9bfd9627ada3360472 (MD5) Previous issue date: 1976 / Resumo: Não informado / Abstract: Not informed / Doutorado / Doutor em Ciências Médicas
17

Uso de matriz óssea desmineralizada associada a estimulação ultra-sônica pulsada de baixa intensidade na correção de falha óssea: estudo experimental em coelhos / not available

Carro, Ana Paula Marzagão Casadei 25 August 1998 (has links)
No presente trabalho, procurou-se investigar o efeito do ultra som pulsado de baixa intensidade corno um agente acelerador do princípio indutor da matriz óssea desmineralizada, utilizada no preenchimento de falhas ósseas, criadas experimentalmente na diáfise do rádio de coelhos. Foram criadas falhas na diáfise do rádio de aproximadamente 1 cm de comprimento, tentando-se preservar ao máximo o periósteo. As falhas foram preenchidas com pó de osso desmineralizado. Os animais foram estimulados com o ultra som, durante 15 dias consecutivos após a cirurgia e foram observados pôr até 30 dias, tendo sido sacrificados aos 15, 30 e 45 dias após a cirurgia. Os resultados foram avaliados radiológica e histologicamente nos 3 períodos, possibilitando um estudo da evolução do processo osteogênico. As falhas ósseas preenchidas com matriz óssea desmineralizada e que receberam o estímulo com o ultra som de baixa intensidade apresentaram uma sensível aceleração no processo de formação de osso, demonstráveis histológica e radiologicamente. / In the present work, it has been investigated the effect of the low intensity pulsed ultrasound on the use of demineralized bone matrix used as bone gap filling material in experimental diaphysial osteotomies of rabbit radius bone. Preserved periosteum 1 cm bone gaps have been surgically created in the radius bone diaphysis and filled with demineralized bone powder. The experimental animals received the ultrasound stimulus for 15 days following the surgery and were observed for until 30 days. The sacrifices were performed 15, 30 and 45 days after surgery. In order to study the healing process evaluation were performed at the end of the 3 periods. The bone gaps whose received demineralized bone matrix and low intensity and low intensity ultrasound simulation presented a remarkable aceleration in the bone formation process as shown by histological and radiological evaluation.
18

Aplicação do ultra-som terapêutico em lesão muscular experimental aguda / not available

Menezes, Denise Ferreira de 17 December 1997 (has links)
Este estudo analisou o efeito da aplicação do ultra-som terapêutico em lesão muscular aguda. Foi realizada uma lesão por esmagamento no músculo reto anterior do quadríceps direito e esquerdo em 26 coelhos (52 músculos) da raça Nova Zelândia, com peso médio de 2,2 kg. Após 3 dias da lesão, os animais foram tratados em um lado com ultra-som terapêutico com tipo de onda pulsada, freqüência de 1 MHz e intensidade de 0,5 W/cm2 por 5 minutos, durante 10 dias consecutivos. O músculo contralateral serviu como controle e sofreu apenas esmagamento. Após 3 dias do término da aplicação, os animais foram sacrificados e os músculos submetidos a ensaios de tração na máquina universal de ensaio, com célula de carga de 200 kgf e velocidade de 4,5 mm/minuto. Foram analisados os resultados dos ensaios de 36 músculos (18 animais), mostrando que os músculos tratados pelo ultra-som apresentaram diferença significativa na deformação máxima, carga e deformação no limite de proporcionalidade, e na energia na fase de deformação elástica. Estes resultados sugerem que a aplicação do ultra-som terapêutico pode ser benéfica para melhorar a qualidade da reparação da lesão muscular aguda. / In this investigation the effect of the therapeutic ultrasound on the healing of acute muscular lesion was evaluated. The injury was produced with a crush on the rectus femoris in 26 New Zealand white rabbits (52 muscles). Three days later pulsed ultrasound was applied to the injuried area and the opposite side muscle was kept a control. The ultrasound pulsed waves had 1 MHz of frequency, 0,5 W/cm2 of intensity and they were applied during 5 minutes for 10 days. Three days after completion of the treatment the animal was killed and the muscle submited to mechanical testing in traction. The muscles treated by ultrasound showed higher loads and deformation at the yield limit and absorbed more energy in the elastic phase. The results suggest that acute muscular lesions may benefit from the application of pulsed ultrasound in the acute phase of the reparative process.
19

Efeitos da estimulação ultra-sônica de baixa intensidade em osteotomias mandibulares: estudo experimental em coelhos. / not available

Vicente, Miriam Fernanda Ragghianti 20 December 2000 (has links)
Vários estudos animais in-vivo e estudos clínicos prospectivos, com grupo controle e duplamente cego mostraram que o ultra-som de baixa intensidade é capaz de acelerar a consolidação de fraturas recentes. A taxa de sucesso é alta no tratamento de fraturas com retardo de consolidação ou não-união (pseudoartrose). O efeito desta tecnologia não-invasiva no tratamento de fraturas da face é desconhecido. O objetivo desta dissertação foi investigar o efeito do ultra-som de baixa intensidade no reparo ósseo da osteotomia de mandíbula. A osteotomia foi realizada no lado esquerdo da mandíbula de coelho e foi fixada com miniplacas de titânio. Foram estabelecidos três grupos experimentais com oito coelhos machos brancos em cada grupo para serem submetidos aquele procedimento cirúrgico. Em cada grupo a osteotomia de quatro animais foi tratada por ultra-som durante 20 minutos/dia. Os outros quatro animais não foram tratados por ultra-som. Os grupos foram diferenciados pelo dia de sacrifício dos animais. Os animais foram sacrificados no 16°, 31° e 46° dias após a cirurgia, respectivamente, para a análise histológica do reparo ósseo nas osteotomias. / Numerous in vivo animal and prospective double blind placebo clinical studies have shown that low intensity pulsed ultrasound is capable of accelerating the healing of fresh fractures. The rate of success is high in the treatment of delayed healing and nonunion. The effect of this noninvasive technology in the treatment of face fractures is unknown. The aim of this dissertation was to investigate the effect of the low intensity pulsed ultrasound in the bone repair of mandible osteotomie. The osteotomie was carried out in the left side of a rabbit mandible which was fixed by titanium miniplate osteosynthese. Eight white male rabbits were randomly assigned to each of three experimental groups to undergo that cirurgical procedure. In each group the osteotomie of four animais was treated by ultrasound 20 minutes/day. The other four animals didn\'t undergo the ultrasound treatment. The groups were distinguished by the day that the animals were sacrificed. Animals were killed after 16, 31 and 46 days of the surgery, respectively, for histologic analysis of the bone repair in the osteotomies.
20

Estudo e avaliação mecânica das juntas soldadas por ultra-som de policarbonato e poli (metacrilato de metila). / Study and avaliation mechanics of join welding by ultrasound of polycarbonate and poli(metacrilate of metila, PMMA).

Souza, Joelmir Mariano de 19 August 2005 (has links)
Nesta pesquisa estudou-se a soldagem de materiais poliméricos por ultra-som, sendo estes, policarbonato (PC) e poli(metacrilato de metila, PMMA. As soldagens foram obtidas através do equipamento especifico para soldagem Soldadoras Integradas, série 900IW, empresa BRANSON Ultrasonics Corporation. Onde detalhamos alguns aspectos do equipamento: mecanismo de soldagem, conversores, transformador e sonotrodo. Para o sonotrodo especificamos a relação de área em função da geometria do mesmo. Ressaltamos também os tipos de métodos de soldagem: direto e indireto, de forma que concluímos que os materiais semicristalinos devem ser soldados apenas pelo método direto em conseqüência destes apresentarem grande perda de amplitude durante a soldagem. Em função destes possuírem uma acentuada queda do módulo de cisalhamento (G) e um aumento no fator de perda mecânica Tang δ acima da temperatura de transição vítrea (Tg), o que prejudica a soldagem. Foram analisados outros fatores que influem no processo de soldagem da junta como: tipos de juntas para uma melhor transmissão de energia, onde verificamos que juntas que possuem um D.R (diretor de energia) apresentam uma boa soldagem, diferente o que acontece com superfícies planas que apresentaram uma soldagem inadequada. Pesquisou-se também a propagação da onda no diretor de energia onde verificamos variações da amplitude através do mesmo. Estudou-se o método para estimar a capacidade de soldagem por ultra-som dos matérias através de fórmulas, onde verificou-se resultados coerentes com os valores reais. Experimentalmente variou-se os parâmetros de soldagem tais como: tempo de soldagem, pressão, e o tempo de recalque, com o intuito de obter-se variações na área soldada e na resistência ao cisalhamento das juntas. Os resultados apresentados pela variação dos parâmetros foram significativos, de modo, que o aumento do tempo de soldagem influenciou em um aumento da área das amostras em 90% das soldagens realizadas, tanto para soldagens similar (de mesmo material) e dissimilar (de materiais diferentes). Com aumento da pressão de soldagem obtivemos resultados menos significativos, ou seja, verificamos que 86,52% das amostras com junção similar, aumentaram a área em função do aumento da pressão. Os outros 13,48% diminuíram a área soldada em função do aumento da pressão, fenômeno causado pela diferença de rechupe encontrado nas amostras injetadas. O aumento do tempo de recalque não apresentou variações de área e de resistência ao cisalhamento significativas. As amostras soldadas apresentam o fenômeno de esbranqueceamento da região unida, onde concluímos que a umidade presente no material e as microrugosidades presentes na superfície do mesmo, causam este fenômeno. O qual pode ser minimizado através de secagem do material antes da injeção. Mediu-se a área soldada, e a resistência ao cisalhamento de todos os tipos de juntas, de forma que obtivemos diferentes valores para cada tipo de material analisado (PMMA e PC) com junções similares (PMMA/PMMA e PC/PC), dissimilares (PMMA/PC) e com direções de injeção similares (HH, VV) e direção de injeção dissimilar (HV). Com estes resultados podemos aplicar o método estatístico de análise de variância em função da variação de área e da variação de resistência. Os resultados da análise de variância foram mais coerentes com os resultados experimentais em função do parâmetro tempo de soldagem. A análise de variância em função da pressão apresentou resultados menos significativos, comparado aos resultados experimentais. As juntas soldadas foram adaptadas da norma ASTM D638M, e para realização do teste de cisalhamento projetou-se um dispositivo especial para esta aplicação. / In this research it was studied welding of polymerics materials by ultrasound, being these, polycarbonate (PC) and poli(metacrilate of metila, PMMA). The weldings had been gotten through the equipment specify for welding (Integrated Soldering, series 900IW, company BRANSON Ultrasonics Corporation). Detail some aspects of the equipment: mechanism of welding, converters, transforming and sonotrode. For sonotrode we specify the relation of area in function of the geometry. Empathized also two types of welding methods: direct and indirect, then we conclude that the semi crystalline materials must be welded only by the direct method, in consequence of these materials to present great loss of amplitude during the welding. In function of these to possess one accented fall of the module of shear (G) and an increase in the mechanics loss factor (Tang δ), above of the glass transition temperature (Tg), these factors it harms the welding. Other factors had been analyzed that influence in the process of welding of the joining, as: geometric of joining for one better transmission of energy, where we verify that joining that possess a D.R (director of energy) these present a good welding, different of others joining with plain surfaces that had presented an inadequate welding. The propagation of the wave in the energy director was also searched where we verify variations of the amplitude through D.R. The method was studied for estimate of the capacity of welding for ultrasound of the materials through formulas, where it was verified coherent resulted with the real results. Experimentally varied the welding parameters such as: welding time, pressure, and the time pressure after welding, with intention to get variations in the welded area and the shear strength of the joining. The results presented for the variation of the parameters had significant, in way, that the increase of the welding time influenced in an increase of the area of the samples in 90% of the carried through weldings, as much for weldings similar (of same material) and dissimilar (of different materials). With increase of the welding pressure we got resulted less significant, or either, we verify that 86.52% of the samples with similar junction, had increased the area in function of the increase of the pressure. The others 13.48% had diminished the area welded in function of the increase of the pressure, phenomenon caused for the difference of contraction found in the injected samples. The increase of the time of the time pressure after welding did not present variations of area and significant shear strength. The welded samples present the phenomenon of change of color of the joined region, where we conclude that the present humidity in the material and the microrugosidades of the surface causes this phenomenon. The change color can be minimized through drying of the material before the injection. It measured welded area, and the shear strength of all the types of joining, and this form we got different values of area and of shear strength for each type of material analyzed (PMMA and PC) with similar junctions (PMMA/PMMA and PC/PC) and dissimilar (PMMA/PC) with similar directions of injection (HH, VV) and direction of dissimilar injection (HV). With these results we can apply the statistical method of analysis of variance in function of the variation of area and in function of the variation of resistance. The results of the variance analysis had been more coherent with the experimental results in function of the parameter welding time. The analysis of variance in function of the pressure presented resulted less significant, comparative to the experimental results. The welded joining had been adapted according to norm ASTM D638M, and for development of the shear test a special device for this application was projected.

Page generated in 0.0395 seconds