• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Emissioner av flyktiga organiska föreningar från vattenburna lacker

Andreasson, Johan January 2009 (has links)
Arbetet har jämfört de emissioner som olika tjocklek på lacklagren samt olika torkningstemperaturer ger upphov till. Det konstaterades att tjocka lager ger upphov till oproportionerligt höga emissioner både på kort och framförallt på lång sikt. En högre torkningstemperatur orsakar lägre emissioner på kort sikt men lika höga eller högre på lång sikt. Inverkan från underlaget som lacken applicerades på undersöktes också och där konstaterades att ett porösare medium, i detta fall en MDF-skiva, orsaker lägre emissioner. Sannolikt pga att ämnena sugs upp av materialet. Den tredje delen bestod i att jämföra olika testkammares förmåga att registrera de sökta ämnena. Två stycken kammare med volymen 1m3 och en liten kammare med volymen 3ml användes. Det visade sig att de båda stora kamrarna visade liknande resultat om tiden efter att lacken applicerats på proverna var densamma. Den mindre visade klart lägre koncentrationer i försöksluften men omräknat till ytspecifik utsöndring var värdena jämförbara. Ämnen med hög kokpunkt var överrepresenterade i den lilla kammaren och ämnen med låg kokpunkt underrepresenterade, vilket gör att kammaren lämpar sig bäst för jämförande studier.
2

Emissioner av flyktiga organiska föreningar från vattenburna lacker

Andreasson, Johan January 2009 (has links)
<p>Arbetet har jämfört de emissioner som olika tjocklek på lacklagren samt olika torkningstemperaturer ger upphov till. Det konstaterades att tjocka lager ger upphov till oproportionerligt höga emissioner både på kort och framförallt på lång sikt. En högre torkningstemperatur orsakar lägre emissioner på kort sikt men lika höga eller högre på lång sikt. Inverkan från underlaget som lacken applicerades på undersöktes också och där konstaterades att ett porösare medium, i detta fall en MDF-skiva, orsaker lägre emissioner. Sannolikt pga att ämnena sugs upp av materialet. Den tredje delen bestod i att jämföra olika testkammares förmåga att registrera de sökta ämnena. Två stycken kammare med volymen 1m3 och en liten kammare med volymen 3ml användes. Det visade sig att de båda stora kamrarna visade liknande resultat om tiden efter att lacken applicerats på proverna var densamma. Den mindre visade klart lägre koncentrationer i försöksluften men omräknat till ytspecifik utsöndring var värdena jämförbara. Ämnen med hög kokpunkt var överrepresenterade i den lilla kammaren och ämnen med låg kokpunkt underrepresenterade, vilket gör att kammaren lämpar sig bäst för jämförande studier.</p>
3

Mikrobiella hot mot nordiskt dricksvatten : En studie av mikrobiella föroreningar i dricksvatten i Norden samt en utvärdering av olika reningsprocesser / Microbial threats to Nordic drinking water : A study of microbial contamination in Nordic drinking water and an evaluation of different water treatment processes

Haag, Jennie January 2015 (has links)
Den största akuta risken inom dricksvattenförsörjningen är vattenburen smittspridning. Dricksvattenrelaterad smittspridning förekommer i störst utsträckning i utvecklingsländer med dåliga sanitära förhållanden. Under 2000-talet har de nordiska länderna drabbats av flertalet dricksvattenburna sjukdomsutbrott vilket har lett till att mikrobiella föroreningar uppmärksammats som ett problem även i Norden. För att säkerställa att det dricksvatten som distribueras är av god mikrobiologisk kvalitet krävs att säkerhetsbarriärerna i vattenverket är tillräckligt effektiva för alla typer av mikrobiella föroreningar. Vissa mikroorganismer har uppmärksammats som mer tåliga mot olika desinfektionsmetoder, till exempel klorering, än vad som tidigare varit känt. För ett säkrare dricksvatten är det därför viktigt att öka kunskapen om mikroorganismers varierande motståndskraft mot olika desinfektionsmedel samt undersöka alternativ till de avskiljnings- och inaktiveringsmetoder som traditionellt används idag. Examensarbetets syfte var att studera de bakterier och virus som har störst relevans för dricksvattenkvaliteten och som tros kunna utgöra ett hot mot nordiskt dricksvatten, att undersöka orsakerna bakom dricksvattenburna utbrott samt att undersöka effektiviteten hos olika avskiljnings- och inaktiveringsmetoder för bakterier och virus. Detta gjordes genom en utförlig litteraturstudie samt en fallstudie. Fallstudiens syfte var att belysa problematiken inom dricksvattenberedning samt distribution i Norden genom verkliga exempel.  Studien visade att vattenburna sjukdomsutbrott normalt orsakas av kontaminering från avloppsvatten till dricksvatten. Detta sker antingen direkt till råvattnet, ofta till följd av kraftig nederbörd, eller under distributionen på grund av driftstörningar. Att kontamineringen tillåts nå konsumenten är ett resultat av inadekvata reningsmetoder i vattenverken. Problematiken inom dricksvattenområdet beror bland annat på användandet av bristfälliga indikatororganismer vilka är mindre tåliga och har sämre överlevnadsförmåga än många sjukdomsalstrande mikroorganismer. Tidskrävande och osäkra analysmetoder utgör också ett stort problem. Svårigheter i att identifiera den orsakande mikroorganismen samt att bekräfta utbrottet som dricksvattenrelaterat har lett till att mörkertalet gällande antalet vattenburna sjukdomsfall är stort. Det finns ett stort behov av ökad kunskap gällande olika mikroorganismers tålighet mot desinfektion samt ett behov av reglering för kontroll av råvattenkvaliteten och den mikrobiologiska säkerheten. Utifrån studien kunde även konstateras att antalet vattenburna utbrott tros öka med kraftigare nederbörd och extremväder till följd av klimatförändringarna. / Waterborne diseases are considered a major problem in the water supply. Spreading of infection through drinking water occurs predominantly in developing countries with poor sanitation. During the 21th century the Nordic countries have been affected by several waterborne outbreaks associated with drinking water. As a result, microbial contamination of drinking water has been recognized as a problem in the Nordic countries as well. To ensure high quality drinking water it is required that the hygienic barriers used in the water treatment plant are efficient in reducing all types of microbial contaminants. Some microorganisms have shown a greater resistance against commonly used disinfectants then previously known. To secure the distribution of safe drinking water it is essential to increase the knowledge regarding the varying resistance of microorganisms and to investigate alternative water treatment processes to those traditionally used in drinking water treatment today.  The objective to this master thesis was to study the bacteria and viruses that are most relevant for drinking water quality and may compose a threat to the drinking water quality in the Nordic countries, to investigate the cause of waterborne outbreaks and to study the effectiveness in reducing bacteria and viruses for various water treatment processes. The study was performed through a thorough literature review and a case study. The purpose of the case study was to illustrate the issues in drinking water treatment and distribution in the Nordic region. The study showed that the majority of the outbreaks are caused by contamination from sewage water to drinking water. The contamination is allowed to reach the consumer as a result of inadequate treatment in the water works. Usage of inappropriate indicator organisms that are less resistant to disinfectants than a lot of pathogens are a big problem in drinking water treatment. Time-consuming and uncertain analytical methods also compose a great issue. Due to difficulties in identifying the causative microorganism and verify the outbreak as drinking water related it is believed that there is a large number of unrecorded cases of illness. There is a great need of increased understanding of the varying resistance of microorganisms to disinfectants and a need for regulation for monitoring raw water quality and microbiological safety. Based on the study it was also found that waterborne outbreaks are believed to increase as a result of extreme weather caused by climate change.
4

Modeling the microbial fate and transport in rivers of South Africa / Modellering av mikrobiell transport i Sydafrikas vattendrag

Perman, Stina January 2021 (has links)
In recent years, surface water used for domestic, industrial, and irrigation purposes in South Africa has deteriorated due to inadequate wastewater treatment, urban and agricultural runoff, and rural settlements with deficient sanitation. Access to safe drinking water and sanitation is a basic human right, and if waterborne pathogens are present in the water environment, they compose a human health risk. With some hydrological models, e.g., Hydrological Predictions of the Environment (HYPE), it is possible to model microbial water quality and predict how land use and climate changes affect recipient water sources. In this thesis, waterborne pathogen transport in South Africa is investigated using World-Wide HYPE (WWH), to increase the understanding of the largest sources affecting pathogen concentration in surface water and processes affecting pathogen transport. Initially, a literature study was performed with emphasis on finding the most suitable pathogen to simulate. Because of the amount of available data, the indicator microorganism, E. coli, was chosen. Observed E. coli concentrations in surface water were used to evaluate the conformity of the simulated concentration, and contributions from separate sources were analysed. A sensitivity analysis was performed to increase the understanding of process parameters affecting the transport of E. coli in WWH. The findings of this project show that the largest contributions of E. coli originate from humans with unsatisfactory waste management, where wastewater is partially released directly to surface water. The largest deviation in average E. coli load per year was obtained when altering t1expdec, which denotes the half-life time of the simulated microorganism. The half-life time was also the process parameter with the most significant effect on the simulated concentration. In addition, when the parameter that specifies the fraction of E. coli that is released directly to surface water was altered, which affects one of the largest E. coli sources, a large deviation in average E. coli load per year was observed. This finding shows the importance of estimating the load from contamination sources accurately. The conformity of simulated and observed E.coli load was acceptable, but the simulated discharge needs to be improved to achieve better conformity of the E. coli concentration in surface water. WWH has great potential to simulate waterborne pathogens, but further developments to improve the simulated discharge are encouraged to obtain more reliable results. / Under de senaste åren har kvaliteten av ytvattnet i Sydafrika försämrats på grund av bristfälliga vattenreningsverk, avrinning från urbana miljöer och åkermark och områden med undermålig sanitet. Att ha tillgång till rent vatten och fungerande sanitet är en grundläggande mänsklig rättighet och om patogener är närvarande utgör detta en hälsorisk för människor som kommer i kontakt med dessa smittoämnen. Det är möjligt att modellera vattens kvalitet med avseende på mikroorganismer och att förutse hur markanvändning påverkar kvaliteten i recipienten. I detta arbete har transporten av vattenburna patogener i Sydafrika undersökts genom World-Wide HYPE (WWH) med syftet att öka förståelsen av de största källorna som bidrar till ökande koncentrationer av patogener i ytvatten, samt att öka förståelsen av processerna som påverkar transporten. En litteraturstudie utfördes för att hitta en passande patogen att simulera, och på grund av mängd tillgängliga data valdes indikatororganismen E. coli. Uppmätt koncentration av E. coli i ytvatten i Sydafrika användes för att utvärdera överrensstämmelsen med simulerad koncentration, och bidrag från olika källor av E. coli analyserades. En kompletterande känslighetsanalys utfördes för att öka förståelsen om transportprocesserna i WWH. Resultatet visade att de största bidragskällorna av E. coli till ytvatten i modellen är människor med otillräcklig hantering av mänskligt avfall där genererat avloppsvatten delvis släpps ut direkt till ytvattnet. Från känslighetsanalysen visade det sig att den mest känsliga modellparametern var t1expdec som beskriver mikroorganismenshalveringstid. Det var också den processparameter som också hade störst påverkan på den simulerade E. coli koncentrationen. När parametern som bestämmer andelen av E.coli som släpps ut direkt till ytvatten varierades, som påverkar en av de största källorna, resulterade det också i stor förändring i genomsnittlig belastning av E. coli per år. Detta indikerar att det är viktigt att estimera bidragskällorna korrekt. Överrensstämmelsen mellan simulerad och uppmätt belastning av E. coli per dag var acceptabel men det simulerade vattenflödet bör förbättras för att uppnå en bättre överrensstämmelse mellan simulerade och uppmätta koncentrationer av E. coli. WWH har stor potential att modellera vattenburna patogener, men vidareutveckling av simulerade vattenflöden behöver utföras att få mer tillförlitliga resultat.
5

Enhancing Comfort and Robustness in Hydronic Radiator Systems through Integration of Body Heat Predictions : A Study on a Novel LPV Controller / Förbättring av Komfort och Robusthet i Vattenburna Elementsystem genom Integration av Kroppsvärme beräkningar

Pirmohamed, Fahim January 2023 (has links)
The quest to balance occupant comfort with energy efficiency is a key challenge in the field of heating systems, particularly for hydronic radiators. This study addresses this issue by investigating the integration of body heat predictions into a gain-scheduling controller for a hydronic radiator system. Although the benefits of gain-scheduling control strategies are acknowledged in HVAC systems, this exploration into the integration of body heat predictions in hydronic radiator systems presents a novel approach. A Linear Parameter-Varying (LPV) controller was employed and its impact on comfort, energy consumption, and robustness in the face of varying parameters such as the number of occupants, inaccuracies in body heat prediction, and set-point temperature changes was examined. This proposed controller was tested in a simulated house heating system made in Simulink. Findings indicated a substantial enhancement in comfort, especially under low-load scenarios. The controller demonstrated notable robustness against disturbances, highlighting the system’s reliability. Although energy consumption did not show significant reduction, the ability to maintain comfort levels without increasing energy use is a valuable contribution to sustainable heating practices. The results of this study extend our understanding of control strategies in hydronic radiator systems, providing a promising approach towards more comfortable, robust, and energy-efficient solutions. Further research should focus on improving the accuracy of body heat prediction algorithms and incorporating renewable energy sources for increased energy efficiency. In sum, this work represents a significant step towards a more balanced and sustainable future in the operation of hydronic radiator systems. / Denna studie utforskar möjligheten att balansera komfort och energieffektivitet i vattenburna elementsystem genom att integrera kroppsvärmeberäkningar i en gain-scheduling regleralgoritm. Vi presenterar en nyanserad metod som använder en Linjär Parameterberoende (LPV) reglerare. Denna reglerare anpassar sig till varierande parametrar som antal personer i rummet, osäkerheter i kroppsvärmeberäkningar och förändringar i inställd temperatur. Den föreslagna regleraren testades i ett simulerat husvärmesystem skapat i Simulink. Resultaten indikerade en betydande förbättring i komfort, särskilt under låglastscenarier. Regleraren uppvisade också anmärkningsvärd robusthet mot störningar, vilket understrykersystemets tillförlitlighet. Även om ingen signifikant minskning i energiförbrukning observerades, är förmågan att bibehålla komfortnivåer utan att öka energianvändningen ett värdefullt bidrag till hållbara uppvärmningsmetoder. Denna studie utökar vår förståelse för reglerstrategier i vattenburna elementsystem och erbjuder en lovande väg framåt mot mer komfortabla, robusta och energieffektiva lösningar. För framtida forskning bör fokus ligga på att förbättra noggrannheten i kroppsvärmeberäkningsalgoritmer och att integrera förnybara energikällor för ökad energieffektivitet. Sammantaget representerar detta arbete ett betydande steg mot en mer balanserad och hållbar framtid i drift av vattenburna elementsystem.

Page generated in 0.1877 seconds