51

Diseño de un sistema de ventilación forzada para los estacionamientos de un supermercado en la ciudad de Lima

Pablo Huamani, Sergio January 2018 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Desarrolla la implementación del sistema de ventilación mecánica para la extracción de monóxido en los estacionamientos del supermercado San Luis ubicado en la ciudad de Lima, con el fin de preservar la integridad del personal y de los clientes. El sistema elegido para su funcionamiento consiste en dimensionar y distribuir los conductos y seleccionar los equipos adecuadamente. El aire limpio lo hacemos ingresar a los estacionamientos es a través de los inyectores centrífugos, a la vez los extractores centrífugos direccionan el aire contaminado que hay en los estacionamientos hacia el exterior. Para realizar el diseño de los conductos se consideraron de las normas ASHRAE (American Society of Heating Refrigerating and Air-Conditioning Engineer), Norma Técnica E.M. 030 instalaciones de ventilación que brindan recomendaciones para garantizar el buen funcionamiento del sistema, también se consideraron los conocimientos adquiridos en la supervisión de campo de la ventilación mecánica. Se hizo el calculó del caudal de aire requerido de los estacionamientos, dimensionamientos de los conductos con las velocidades recomendadas y selección de equipos de ventilación, para satisfacer el buen funcionamiento del sistema de extracción de monóxido. Además, se asegura que la concentración de monóxido de carbono por debajo de 35 ppm, en cumplimiento con las normas ASHRAE, y que a su vez cumpla las cinco renovaciones por hora de acuerdo a lo establecido en el reglamento nacional de edificaciones (RNE). / Trabajo de suficiencia profesional
52

Metodologia para a análise estrutural estática e dinâmica de ventiladores centrífugos: emprego de métodos analíticos e numéricos. / Methodology for static and dynamic structural analysis of centrifugal fans: employment of analytical and numerical methods.

André Schiavon Perez Ortigosa 09 August 2012 (has links)
A análise de tensões em impelidores de ventiladores centrífugos pelo método dos elementos finitos revela que seus componentes são altamente solicitados e sujeitos a campos de tensões complexos. Tradicionalmente, o projeto estrutural de impelidores centrífugos é realizado a partir do cálculo das tensões estáticas provenientes da força centrífuga, e o comportamento dinâmico do impelidor é frequentemente verificado através de estudos de vibrações livres frente ao conhecimento das fontes de excitação. Por tal abordagem não é realizada qualquer avaliação quanto aos níveis de tensões dinâmicas nos componentes do impelidor. Neste trabalho, contudo, a determinação das tensões dinâmicas é apresentada como uma importante ferramenta para avaliar a integridade estrutural de um impelidor centrífugo durante a sua operação. Para tanto, cálculos de resposta são realizados no rotor e, isoladamente, no impelidor de um ventilador centrífugo, conduzindo a uma nova metodologia para a análise estrutural destes equipamentos através do método dos elementos finitos. / Stress analysis of centrifugal fan impellers through the finite element method reveals that its components are highly stressed and subjected to complex stress fields. Traditionally, the mechanical design of centrifugal impellers is performed from the study of the static stress levels due to the centrifugal force. The impeller dynamic behavior is evaluated through free vibration analysis and also with the knowledge of the main excitation sources. This approach does not consider any assessment on the dynamic response of the impeller components. In this work, however, the dynamic stress determination is presented as an important tool in order to evaluate the structural integrity of centrifugal fan impellers during its operation. For this purpose, frequency response analysis is performed on the rotor and, separately, on the centrifugal fan impeller, leading to a new methodology for structural analysis of these equipment through the finite element method.
53

Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung model

Couto, Lara Poletto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.
54

Self-tuning PID and Fuzzy controllers in industrial plants / Controladores PID auto-ajustÃvel e nebuloso aplicados em plantas industriais

Felipe de Azevedo GuimarÃes 01 October 2007 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / With the globalization and the competitiveness in all the levels of the industrial sector, the final product quality search became higher. On the other hand, energy saving became another important factor in modern industry. The consumption of electric energy in the industrial sector represents 45.5% of the total consumption of the country. The motor force represents most of this consumption, arriving to be superior of 80% in the textile, paper and cellulose sectors. This work presents two strategies of control, auto-adjustable PID and fuzzy controller, the objectives are a better final product quality and the energy saving. Ventilation and compression industrials process are used in this work. An analysis of limit cyclesâ presence through the descriptive function of the fuzzy controller is carried through, providing a previously validation of fuzzy controllerâs parameters by simulations, saving time in the adjust phase. Set-point changes are easily made and on-line, still the process is running, in the two considered controllers. Comparisons of energy consumption are made between the conventional strategies and the two strategies considered in this work. / Com a globalizaÃÃo e a competitividade em todos os nÃveis do setor industrial, a qualidade do produto final se tornou de importÃncia crescente. Por outro lado, a conservaÃÃo de energia no setor industrial se tornou outro fator importante na indÃstria moderna. O consumo de energia elÃtrica do setor industrial representa 45,5% do consumo total do paÃs. A forÃa motriz representa a maior parte deste consumo, chegando a ser superior a 80% nos setores tÃxtil, de papel e celulose. Este trabalho apresenta duas estratÃgias de controle, PID auto-ajustÃvel e controlador nebuloso, e tÃm como objetivos tanto a qualidade do produto final quanto a eficiÃncia energÃtica. SÃo utilizados processos de ventilaÃÃo e de compressÃo em escala industriais. Uma anÃlise da presenÃa dos ciclos limites atravÃs da funÃÃo descritiva do controlador nebuloso à realizada, de forma que os parÃmetros do controlador nebuloso podem ser previamente validados atravÃs de simulaÃÃes, poupando tempo na fase de ajuste dos parÃmentros do controlador. MudanÃas de set-point sÃo facilmente realizadas de forma online e sem que o funcionamento do processo seja descontinuado, nos dois controladores propostos. ComparaÃÃes quanto ao consumo de energia sÃo realizadas usando as estratÃgias de controle convencionais e as proposta neste trabalho.
55

Estudo do funcionamento da ventilação assistida proporcional plus em um sistema pulmonar mecânico / Study of the functioning of the proportional assist ventilation plus in a mechanical lung model

Lara Poletto Couto 13 August 2012 (has links)
INTRODUÇÃO: Ventilação assistida proporcional plus é um novo conceito de suporte ventilatório assistido que visa atuar de acordo com os níveis de esforço inspiratório, mecânica respiratória e níveis de porcentagem de apoio. A complexa interação entre esses fatores que comandam a sua função é de difícil interpretação na prática clínica. O objetivo deste estudo é provocar alterações na complacência, resistência e esforços inspiratórios, em um sistema pulmonar mecânico, para entender o funcionamento e as respostas desse modo nas suas diferentes porcentagens de apoio. MÉTODOS: No Laboratório de Ventilação Mecânica da Disciplina de Pneumologia da Faculdade de Medicina da Universidade de São Paulo, um ventilador Interplus da marca Intermed foi conectado em um pulmão mecânico da marca Michigan Instruments Inc, com a finalidade de gerar diferentes níveis de esforços inspiratórios e para disparar o ventilador Puritan-Bennett 840 da marca Covidien. Os volumes correntes expirados foram medidos e posteriormente comparados através do método estatístico ANOVA two-way, para 10 níveis de porcentagem de apoio (de 5% a 95%), 3 níveis de complacência (50, 100 e 150 mL/cmH2O), 3 níveis de resistência (5, 20 e 50 cmH2O/L/s) e 4 níveis de esforço inspiratório (-2, -5, -8 e -15 cmH2O). RESULTADOS: Trezentas e sessenta medidas de volume corrente expirado foram obtidas. Os volumes correntes expirados aumentaram significativamente com o incremento dos esforços inspiratórios, durante altos esforços inspiratórios e altas complacências. Diminuíram significativamente durante o incremento das resistências, especialmente quando combinado com baixos esforços inspiratórios e baixas complacências. O fenômeno de sobreassistência (runaway) ocorreu com porcentagem de apoio de 95% combinada com alta resistência e alta complacência. CONCLUSÃO: O modo ventilação assistida proporcional plus respondeu adequadamente às alterações provocadas nas complacências e nos esforços inspiratórios testados. Respondeu à situações de resistência extremamente alta somente quando associado com altos esforços inspiratórios. Não houve fenômeno de sobreassistência em porcentagens de apoio menores que 95%. / BACKGROUND: Proportional assist ventilation plus (PAV+) is a new concept of assist ventilatory support conceived to act according to the levels of inspiratory efforts, respiratory mechanics and percentages levels of assistance. This complex interaction among the factors commanding its function is difficult to detect in clinical setting. This study aimed to provoke changes in compliance, resistance and inspiratory efforts in a lung simulator to understand the responses of PAV+ support. METHODS: In the Mechanical Ventilation Laboratory at University of São Paulo, an Inter Plus ventilator (Intermed ®) connected to lung simulator (Michigan Instruments Inc) acted triggering Puritan-Bennett 840 ventilator (Covidien ®) at different levels of inspiratory efforts. Expiratory tidal volumes were measured and compared (ANOVA-2-way) at 10 levels of PAV+ support (from 5% to 95%), 3 levels of lung simulator compliance (50, 100, 150 mL/cmH20), 3 levels of airway resistance (5, 20, 50 cmH20/L/s) and 4 levels of inspiratory effort ( -2, -5, -8, -15 cmH20). RESULTS: A total of 360 tidal volumes were measured. They increased significantly during increment of inspiratory efforts and during higher inspiratory efforts with higher compliances. They decreased significantly during respiratory resistance increments, especially when combined with low inspiratory efforts and compliances. Runaway occurred during PAV+ support of 95% combined with high respiratory resistance and compliance. CONCLUSIONS: PAV+ responded adequately to provoked changes in the tested respiratory compliances and inspiratory efforts. It responded to very high resistance only when associated with high inspiratory efforts. There was no runaway phenomenon during PAV+ assistance below 95%.