• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • Tagged with
  • 52
  • 52
  • 52
  • 51
  • 32
  • 30
  • 29
  • 24
  • 24
  • 23
  • 23
  • 23
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise do comportamento estrutural de ligações em aço entre viga de seção I e pilar de seção tubular circular / Structural behavior of steel connections between I-beam and circular hollow section column

Daniel Henrique Fidelis Pereira 08 November 2013 (has links)
Esta pesquisa consiste de uma investigação acerca do comportamento estrutural de ligações entre viga de seção I e pilar de seção tubular circular em situações de pilar de canto e de pilar solicitado por quatro vigas simultaneamente (pilar central). A associação entre a viga de seção I e o pilar de seção tubular circular remete à análise de ligações com comportamento complexo. A partir da análise numérica, via Método dos Elementos Finitos com os softwares ANSYS® e TrueGrid® foi avaliado o comportamento momento-rotação e parâmetros como resistência, rigidez inicial e ductilidade das ligações. Foram analisadas as tipologias de ligação soldada e ligação com a presença do diafragma externo como mecanismo de enrijecimento. Avaliou-se a influência de 6 variáveis, sendo o comprimento da viga, a espessura do pilar, a força aplicada nas vigas dispostas ortogonalmente, a compressão axial do pilar, a espessura do diafragma e o diâmetro dos parafusos do diafragma totalizando 20 modelos numéricos. O aumento da espessura da seção do pilar e a força aplicada simultaneamente nas 4 vigas representou uma melhoria na resistência e rigidez inicial das ligações soldadas. A redução do diâmetro dos parafusos do diafragma foi a principal variável capaz de influenciar negativamente as propriedades de rigidez inicial e resistência das ligações com o diafragma. Todos os modelos analisados apresentaram comportamento semi-rígido segundo o Eurocode 3 (2005). O dimensionamento analítico pelo Eurocode 3 (2005) e por Winkel (1998) apresentou boa aproximação com os resultados da análise numérica. A obtenção da resistência das ligações com diafragma pelo método das componentes apresentou resultados, em média, 20% inferiores ao verificado na modelagem numérica. A utilização do diafragma como mecanismo de enrijecimento das ligações mostrou-se eficiente. As ligações soldadas apresentaram maior ductilidade comparada às com diafragma. O aumento da espessura do pilar nas ligações soldadas demonstrou-se uma alternativa eficaz no enrijecimento das ligações. / This research consists of an investigation above the structural behavior of connections between I-beam and circular hollow section (CHS) columns in situation of corner columns and column loaded by 4 beams simultaneously (inside columns). The association between the I-beam and the CHS column presupposes the analysis of connections with a complex structural behavior. Based on a numerical analysis, using the Finite Element Method with ANSYS® and TrueGrid® softwares, the connection parameters like strength, stiffness and ductility was evaluated. The typologies of welded connections and connections with an external diaphragm was analyzed. An amount of 6 variables (beam length, column thickness, force applied on the beams, compression of the column, diaphragm thickness and bolt diameter) was analyzed in a total of 20 numerical specimens. The increase of the column thickness and the force applied simultaneously on the 4 beam ends culminated on a substantial improvement on strength and stiffness of the welded connections. The reduction of the diaphragm bolts diameter was the main reason for the negatively influence on strength and stiffness properties of the diaphragm connections. All specimens presented a semirigid behavior according to the Eurocode 3 (2005). The analytical design, based on the Eurocode 3 (2005) and Winkel (1998), obtained good results in terms of connections strength compared with the numerical analysis. The obtainment of the connections strength with the component method demonstrated results 20% less than numerical analysis. The external diaphragm as a stiffening mechanism showed effective. The welded connections presented more ductility than the diaphragm ones. The increase on the column thickness demonstrated an effective alternative for the connection stiffening.
32

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Lisiane Pereira Prado 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
33

Ligação viga-pilar em elementos pré-moldados de concreto solidarizados por concreto reforçado com fibras de aço: análises estática e dinâmica / Beam-column connection in precast concrete structures using steel fiber reinforced concrete

Luiz Álvaro de Oliveira Júnior 13 June 2012 (has links)
No presente trabalho, utiliza-se concreto com fibras de aço, traspasse de armaduras e chaves de cisalhamento para desenvolver uma ligação viga-pilar capaz de resistir a ações cíclicas e dinâmicas e que possa ser empregada na pré-moldagem de estruturas de casas de força de usinas hidrelétricas. Para atingir este objetivo, inicialmente foram realizados ensaios de caracterização dos materiais, cujos resultados mostraram aumentos de 34% na resistência à tração na flexão, 16% na resistência à compressão e 33% na tenacidade, comprovando os efeitos benéficos das fibras de aço nas propriedades mecânicas do concreto. Em seguida, foram realizados ensaios de tração em tirantes, cujos resultados sugeriram que um comprimento de 15Ø é suficiente para que a emenda desenvolva as tensões de aderência de modo adequado; e ensaios de cisalhamento, cujos resultados mostraram que a ligação viga-pilar resiste a tensões de cisalhamento direto de até 0,77 MPa. Na sequencia, foram realizados ensaios cíclicos em dois modelos cruciformes para caracterização da ligação (um monolítico e outro de concreto pré-moldado, o qual empregava concreto com 1% de fibras na região da ligação), sendo o carregamento aplicado em cinco níveis de força, cada um com dez ciclos de carregamento e descarregamento. Os resultados desses ensaios mostraram que a ligação do modelo em concreto pré-moldado apresentou 85% da resistência do modelo monolítico e ruptura governada por flexão. Por fim, os ensaios dinâmicos foram realizados nos modelos cruciformes em três diferentes situações (íntegros, fraturados e após ruptura da ligação) para estimar o coeficiente de amortecimento, o qual sofreu uma redução de 31% após o ensaio cíclico. Simulações computacionais foram realizadas para complementar a investigação realizada neste trabalho. Elas mostraram representação aceitável da rigidez, mas não da resistência do modelo. / In the present work, steel fiber reinforced concrete, splicing bars and shear keys are used in order to develop a beam-column connection able to support cyclic and dynamic loadings and which can be used in precasting power houses structures of power plants. To achieve this goal, tests were carried out to characterize the materials, which showed increases of 34% in flexural tensile strength, 16% in compressive strength and 33% in toughness factor, confirming the beneficial effects of steel fibers in mechanical properties of the concrete. Then, tensile tests were carried out on rods, whose results suggested that a length of 15Ø can assure appropriate development of bond stresses through the splice; and shear tests, whose results showed that the beam-column connection resists to shear stresses of up to 0,77 MPa on shear key. After, cyclic tests were performed in two cruciform models in order to characterize the beam-column connection (one monolithic and the other precast concrete, which employed 1% steel fiber reinforced concrete in connection region, being the loading applied in five loading levels, each one in 10 cycles of loading and unloading. Results of these tests showed that precast beam-column connection presented 85% of the strength presented by the monolithic model and bending failure. Finally, dynamic tests were performed in cruciform models in three different situations (uncracked, cracked and after failure) for estimating the damping ratio, which was reduced by 31% after cycles. Computer simulations were performed to complement the research developed in this work. They showed acceptable representation of stiffness, but the strength of the model.
34

Estudo da transferência de forças de cisalhamento na ligação entre pilares mistos preenchidos e vigas / A study on shear forces transfer of connections involving steel beams and concrete-filled steel tubular columns

Cynthia Meilli Silva Araujo 08 September 2009 (has links)
Este trabalho tem por objetivo investigar as ligações viga-pilar misto preenchido, no tocante à transferência de forças de cisalhamento na região de ligação. O estudo engloba uma investigação experimental com ensaios do tipo push-out com carregamento centrado no núcleo de concreto e uma simulação numérica no pacote computacional DIANA visando obter dados de comportamento do mecanismo de transferência de forças de cisalhamento, aplicado à região de ligação viga-pilar. Foram utilizados modelos com 800 mm de altura e seção quadrada de dimensão (200 x 200 x 6,3) mm obtida a partir da composição de dois perfis U (200 x 100 x 6,3) mm. A resistência à compressão média do concreto de preenchimento foi de 50 MPa. Ao todo, foram ensaiados 3 modelos de ligação, utilizando chapas de extremidade e barras rosqueadas como mecanismo de ligação viga-pilar. Como elementos para transferência de forças entre o tubo de aço e o núcleo de concreto foram usados conectores tipo pino com cabeça ou cantoneiras. Os resultados experimentais mostraram a eficiência das barras rosqueadas e dos conectores de cisalhamento na transferência dos esforços de cisalhamento na ligação viga-pilar e na interface perfil de aço e concreto. A simulação numérica teve concordância satisfatória com os resultados experimentais obtidos. / In the design of concrete-filled steel tubular columns, the concrete and the steel tube must work together in order to achieve the overall resistance, stiffness and stability requirements. It is important that exists an adequate mechanism to transfer the forces from the steel beam to the steel tube, and then to the concrete core. This work presents a study on shear transfer in connections involving concrete-filled steel tubular columns and steel beams. The work was divided in two parts, being the first an experimental analysis with push-out tests, and the second one a numerical simulation of the tests, using the software DIANA. The tested specimens were 800 mm height , with square section (200 x 200 x 6,3mm) obtained from two welded U-shape profiles. A concrete with compressive strength of 50 MPa was used as a filling for the columns. Altogether, three connections with steel end plates and passing bars were tested. Two types of shear connectors between steel column and concrete core were used: stud-bolts and angles, and a reference specimen without connectors was also tested. The results showed the efficiency of the shear connectors in the tranference of forces.
35

Reforço e incremento da rigidez à flexão de ligações viga-pilar de estruturas de concreto pré-moldado com polímero reforçado com fibra de carbono (PRFC) / Flexural strengthening and stiffness increasing of precast beam-to-column connections by NSM CFRP strips

Tatiana de Cássia Coutinho Silva da Fonseca 18 December 2007 (has links)
Este trabalho apresenta o desenvolvimento de uma técnica de incremento da resistência e da rigidez à flexão de ligações de elementos de concreto pré-moldado, com aplicação de laminados de polímero reforçado com fibra de carbono (PRFC). O procedimento adotado consiste na colagem dos laminados de PRFC em entalhes no concreto de cobrimento, de acordo com a técnica conhecida como \"near-surface mounted\" (NSM), de modo a incorporar à ligação novos elementos resistentes à tração. Para solidarizar a ligação e possibilitar a transferência de esforços de compressão entre os elementos de concreto existentes, preenchem-se os espaços vazios (grauteamento) com argamassa fluida à base de cimento Portland. Foram desenvolvidos modelos em escala reduzida, com o intuito de representar os mecanismos resistentes de uma ligação viga-pilar composta por encaixe de dente Gerber e consolo, com uso de chumbador, almofada de apoio e graute. Esse tipo de ligação é muito utilizado na construção de galpões e tem, na sua concepção original, comportamento essencialmente de articulação. Em uma etapa preliminar, realizaram-se ensaios para a caracterização da aderência segundo a configuração de reforço proposta. Os resultados dessa análise subsidiaram a fixação do comprimento de laminado a ancorar e a escolha do tipo de resina a empregar para colagem do reforço. Os modelos representativos da técnica de reforço proposta foram preparados, cada um deles, pela montagem de um elemento de pilar-consolo com elementos de viga nos respectivos chumbadores e almofadas. Foram também preparados modelos de referência para o estudo da influência da almofada de apoio e do grauteamento no comportamento resistente e da deformabilidade da ligação. Nesses modelos, as juntas eram perfeitamente conjugadas, isto é, os trechos de viga foram concretados com um elemento pré-moldado de pilar-consolo posicionado dentro da fôrma, sem disposição de almofadas. Todos os modelos de ligação foram reforçados e submetidos a ensaios estáticos. Esses ensaios consistiram na aplicação de carregamento cíclico alternado de curta duração, solicitando-se os modelos a momento fletor positivo ou negativo. Este trabalho também apresenta procedimento executivo de ensaios dinâmicos para avaliação da rigidez dos modelos de ligação em três condições: modelo íntegro reforçado, modelo reforçado fissurado (após aplicação de carregamento de aproximadamente 30% do carregamento de ruptura da ligação, em ensaio estático) e modelo reforçado rompido. Com o reforço, a ligação apresentou comportamento semi-rígido e adquiriu resistência à flexão compatível à de estrutura monolítica armada com barras de PRF. / This work presents the development of a technique for flexural strengthening and stiffness increasing of precast beam-to-column connections by the embedding of FRP strips into grooves made on the concrete cover. According to this technique, the tension in the connection is transferred by the Near-Surface Mounted (NSM) FRP strips. To allow the transference of compression efforts among the concrete elements, the empty spaces are filled out with grout. Small-scale specimens were developed to represent the resistant mechanisms of pined beam-to-column connection composed by elastomeric cushion and dowels. Preliminary experimental tests on bond behavior of NSM strips were carried out. The results analysis conducted the decision about the adhesive type and bond length to be employed in the beam-to-column connection specimens. Each specimen was made of the assembly of a column section connected to beam sections through their respective dowels and cushions. The connection specimens were reinforced by embedding CFRP strips in the lateral concrete cover and filling out the spaces between beams and column. In addition, control specimens were prepared to study the influence of the cushion and grout in the connection performance. In those models, the joints were conjugated perfectly, which means that the beam sections were laid inside the wooden forms and cast together with a precast column section with no cushions between them. Experimental static and dynamic tests were done. The tests results show that strengthened connection exhibits semi-rigid behavior and acquires flexural strength compatible to monolithic structure reinforced with FRP bars.
36

Estudo teórico-experimental de ligação viga-pilar com almofada de argamassa e chumbador para estruturas de concreto pré-moldado / Theoretical and experimental study of beam-to-column connection with pad of mortar and bolts for precast concrete structures

Fábio Yoshio Sawasaki 05 May 2010 (has links)
As ligações com chumbador e almofada, sem continuidade estrutural, são comumente empregadas em obras de concreto pré-moldado como galpões, edifícios de poucos pavimentos e no topo de pilares. Na análise estrutural, este tipo de ligação é caracterizado como articulado. Este trabalho teve como objetivo fazer um estudo com este tipo de ligação levando em conta que a transferência de momento fletor ocorrerá em função da rigidez proporcionada por uma almofada de compósito de argamassa e por chumbadores de aço. A idéia é considerar o benefício da redução das solicitações nos elementos de concreto pré-moldado, particularmente, na base dos pilares. A análise experimental foi feita com modelos em escala reduzida 1:2. Foram ensaiados quatro modelos da ligação que são: a) Modelo 1 - chumbadores de aço CA-25 e almofada de compósito de argamassa; b) Modelo 2 - chumbadores de aço CA-25 e almofada de policloropreno; c) Modelo 3 - chumbadores de aço CA-50 e almofada de compósito de argamassa e; d) Modelo 4 - chumbadores de aço CA-50 e pilar com largura igual a 50% maior que os casos anteriores e almofada de argamassa. Foi feita ainda a análise numérica tridimensional dos modelos da ligação utilizando o software Ansys e análises de pórtico plano para avaliar a distribuição de solicitações ao longo de estruturas representativas. Foi desenvolvido um modelo de projeto para prever o comportamento da ligação. Com as simulações de pórtico plano, onde foram consideradas as semirigidezes das ligações, obteve-se uma redução de até 48% do momento fletor na base dos pilares para um edifício de quatro pavimentos, cujas ligações viga-pilares apresentavam um consolo de 40 cm, e de 21,8% para um edifício de um pavimento do tipo galpão, cujas ligações continham quatro chumbadores, considerando apenas a carga de frenagem. A análise de deslocamentos nos pórticos planos também aponta o benefício da consideração da semirigidez nas ligações. Uma redução de deslocamento horizontal do topo do pórtico do tipo galpão de até 32,8% para o modelo com ligações com quatro chumbadores e somente força horizontal, e de até 71,9% para o edifício de quatro pavimentos considerando as ligações semirígidas com consolos de 40 cm. / Connections with bolts and pad, without structural continuity, are commonly used in construction of precast concrete as one-storey building, building with a few storeys and on top of columns. In structural analysis, this type of connection is characterized as pinned, that is, without restriction of the rotation on the connection. This work aims to make a study of this type of connection taking into account that the transfer of bending moment will occur due to the stiffness provided by a pad of mortar composite and the steel bolts. The idea is to consider the benefit of reducing the demands on the elements of precast concrete, particularly at the base of the columns. The experimental analysis was done with models scale 1:2. Four models of connection were tested: a) Model 1 - steel bolts CA-25 and pad of mortar composite, b) Model 2 - steel bolts CA-25 and chloroprene rubber pad, c) Model 3 - bolts of CA-50 steel and pad of mortar composite, and d) Model 4 - steel bolts CA-50 and column with a width of 50% larger that the others and mortar pad. It was still a three-dimensional numerical analysis of the lead models using Ansys software and frame plan analysis to evaluate the stress distribution along the representative structures. A model design to predict the behavior of the connection was developed. Based on the numerical simulations on precast concrete frames, semi-rigidity of connections was take in to account, it was obtained a reduction of up to 48% of the bending moment at the base of the columns of a four-storey building, which beam-to-column connections had a corbel 40 cm, and 21,8% for a one-storey building, which connections contained four bolts, considering only the horizontal load. The analysis of displacements in the plane frame also shows the benefit of considering the semi-rigidity connections. Reduction in horizontal displacement of the top of the one-storey building to 32,8% for the model with four bolts in the connections with only horizontal force, and 71,9% for the four-storey buildings with semi-rigid connections considering the corbels of 40 cm.
37

Estudo do comportamento estrutural de ligações parafusadas viga-pilar com chapa de topo estendida: análise numérica / Analysis of structural behavior of extended end-plate bolted beam-to-column connections: numerical analysis

Pedro Diego Almeida Bergamasco 09 August 2012 (has links)
Este trabalho apresenta um estudo do comportamento estrutural das ligações metálicas parafusadas viga-pilar com chapa de topo estendida. Enfatiza-se a fundamentação teórica, abordando os principais conceitos, os métodos de dimensionamento apresentados em normas internacionais e os principais sistemas de classificação de ligações existentes. O objetivo deste trabalho é apresentar uma metodologia capaz de aprimorar a análise numérica de ligações, com relação aos estudos anteriores, obtendo resultados com melhor representatividade do comportamento real das ligações. Desenvolve-se análise numérica, via Método dos Elementos Finitos (MEF), com a elaboração de diversos modelos numéricos tridimensionais de ligações parafusadas com chapa de topo estendida. Utilizou-se na modelagem numérica o código de pré-processamento TrueGrid® e o código de análise numérica ANSYS®. Os modelos foram desenvolvidos e validados a partir de resultados experimentais. Na análise dos resultados foram comparados os resultados numéricos obtidos com resultados experimentais previamente conhecidos. Faz-se uma abordagem das propostas de dimensionamento apresentadas por normas internacionais em comparação com os resultados numéricos. Através da variação de parâmetros, como espessura da chapa e diâmetro dos parafusos, observam-se os modos de falha das ligações, e a plastificação da chapa de topo e dos parafusos. Por fim, apresenta-se a conclusão do trabalho e sugestões para pesquisas futuras. / This work presents a study about the structural behavior of extended end-plate bolted beam-to-column steel connections. Emphasizes the theoretical foundation, addressing the main concepts, the design methods presented in international standards and the main classification systems for connections existing. The objective of this work is to present a methodology capable of improving the numerical analysis of connections, in comparison with previous studies, getting results with better representation of the actual behavior of the connections. It develops numerical analysis via Finite Element Method (FEM) with the development of various numerical models of three-dimensional bolted end plate connections. It was used in numerical modeling the preprocessing code TrueGrid® and the numerical analysis code ANSYS®. The models were developed and validated from experimental results. In the analysis of the results were compared the numerical results obtained with experimental results previously known. It approaches the design proposals presented by international standards in comparison with the numerical results. By varying the parameters such as end-plate thickness and bolts diameter, it was observed failure modes of the connections, as well as yielding mechanism at the end-plate and bolts. Finally, it presents the conclusion of the work and suggestions for future researches.
38

Comportamento de chumbadores embutidos em concreto com fibras de aço para ligações viga-pilar de concreto pré-moldado / Behavior of dowel embedded in steel fibers concrete for beam-column connections in precast concrete

Ellen Kellen Bellucio 23 March 2016 (has links)
O presente trabalho trata do estudo do comportamento de chumbadores grauteados inseridos em concreto com fibras de aço em ligações viga-pilar de estruturas de concreto pré-moldado. Este estudo é importante para se entender e poder quantificar a influência da rigidez deste componente no comportamento de ligações semirrígidas de estruturas de concreto pré-moldado. O objetivo do trabalho é estudar o mecanismo do chumbador no concreto com fibras de aço em ensaios específicos e avaliar também o comportamento de uma ligação viga-pilar de concreto pré-moldado utilizando estas fibras no consolo e no dente da viga. Nesta pesquisa foi realizado um programa experimental no Laboratório de Estruturas da EESC, uma análise numérica com o emprego do software DIANA® e uma comparação com formulações analíticas existentes para o cálculo da força última destes componentes. Foram ensaiados nove modelos experimentais para avaliar especificamente o mecanismo resistente do chumbador, variando-se os diâmetros das barras, sua inclinação e a porcentagem de fibras de aço no concreto. Além destes modelos, foi realizado ensaio de uma ligação viga-pilar de concreto pré-moldado para avaliar a rigidez da ligação com chumbador inserido em concreto com fibras de aço. Nos ensaios experimentais dos chumbadores observou-se que modelos com concreto com fibras de aço apresentam rigidez até 25% maior se comparado ao modelo com concreto convencional. Verificou-se que o graute utilizado para solidarizar os chumbadores exerce significativa influência na capacidade última do modelo, podendo diminuir em cerca de 30% a capacidade de carga. A ligação viga-pilar de concreto pré-moldado utilizando concreto com fibras de aço no consolo e no dente da viga se comportou de maneira satisfatória, não apresentando fissuração na interface dos diferentes concretos. Na comparação dos modelos ensaiados com as formulações teóricas extraídas de trabalhos de referência verificou-se que, para os modelos específicos de chumbador, a formulação existente é representativa. Para a ligação viga-pilar, alguns ajustes na formulação analítica se fizeram necessários para considerações de efeitos de grupo e de borda observados e decorrentes da utilização de dois chumbadores na ligação proposta neste trabalho. / This research deals with the study of the behavior of grouted dowels embedded in concrete with steel fibers. This study is important to understand and quantify the stiffness transmitted by this component in a semi-rigid connection of precast concrete structures. The objective is to study the mechanism of the dowel in the concrete with steel fibers and evaluate the mechanical behavior of a precast beam-column connection using this type of concrete on the corbels and in the dapped-end beam. In this research, an experimental program in the EESC Structures Laboratory was carried out, as well as a numerical analysis with the use of DIANA® software and a comparison with existing formulations to calculate these components. Nine models were experimentally tested to specifically evaluate the dowel resistant mechanism by varying the diameters of the bars, the declination and the percentage of steel fibers in concrete. Furthermore, an experimental test was performed in order to evaluate the behavior of the connector. The results indicate that for the dowels with concrete and steel fibers, the ultimate capacity of the connection occurs by failure of the connector (excessive deformation of the bars), while in conventional concrete this capability is associated with the rupture of the concrete and that the concrete with steel fibers decreases by 25% the deformability of the models. The grout has a significant impact on the ultimate capacity of the model, which may increase in less than 30%. In the analysis of the beam-column connection, it is possible to observe that the proposed connection exceeds by more than 20% the ultimate capacity compared to traditional beam-column connections. In comparing the theoretical models tested with the formulations shown by previous studies, it was found that for specific models dowels, the existing formulation is representative. For the beam-column connection, adjustment was performed in the previous formulation considerations group and edge effects that occur due to the use of two dowels on the tested connection.
39

Análise teórica e experimental de ligações viga mista-pilar de extremidade com cantoneiras de assento e alma / Theoretical and experimental analysis of single-sided beam-to-column composite joints with bottom and web angle connections

Tristão, Gustavo Alves 05 May 2006 (has links)
Este trabalho apresenta um estudo numérico e experimental do comportamento estrutural das ligações viga mista-pilar com cantoneiras de assento e alma. No estudo teórico foi desenvolvido, com base nos EUROCODES 3 e 4, um procedimento para avaliação do comportamento das ligações mistas com cantoneiras de alma e assento e com chapa de topo. O trabalho de investigação experimental, abrangendo modelos submetidos a carregamentos monotônico e cíclico, foi realizado no Instituto Superior Técnico (IST), Portugal, em que o objetivo principal foi avaliar a influência da força axial de compressão no pilar para o comportamento do painel da alma do pilar, e conseqüentemente no comportamento global da ligação mista localizada em nó de extremidade. Nos ensaios experimentais foram analisadas as rotações e deformações no painel da alma do pilar sem e com enrijecedor na alma do pilar. Adicionalmente, a eficiência da ancoragem das barras de armadura longitudinal foi verificada. Paralelamente à investigação experimental, um estudo numérico de ligações mistas foi realizado por meio do modelo em elementos finitos, o qual mostrou-se representativo, tornando-se uma ferramenta para análises paramétricas. / This work presents a numerical and experimental study of the structural behavior of beam-to-column composite joints with bottom and web angle connections. In the theoretical study, basing in EUROCODES 3 and 4, an analytic procedure for evaluation the static behavior of beam-to-column composite joints with bottom and web angle connections was developed. The experimental test program, enclosing monotonic tests and a cyclic test, was carried out at the Instituto Superior Técnico of Lisbon (IST), where the main objective was to evaluate the effect of column axial load on column web panel and consequently in the global behavior of single-sided composite joint. In the tests, the panel zone rotations and deformations were analyzed for stiffened and unstiffened column web. In addition, the efficiency of the main rebar was verified. Finally, a thorough of finite element model, a numerical study of composite joints was developed. This model was found to be representative and reliable as a tool to futures parametric analyses.
40

Pilares mistos preenchidos : estudo da flexo-compressão e de ligações viga-pilar / Concrete filled steel columns : a study of combined bending and compression and beam-column connections

De Nardin, Silvana 03 June 2003 (has links)
Este trabalho aborda o estudo de pilares preenchidos flexo-comprimidos e algumas ligações viga-pilar preenchido. Para ambos, são realizadas experimentações com modelos físicos e numéricos, sendo que para os pilares preenchidos um amplo estudo paramétrico foi desenvolvido. Ao todo, foram ensaiados 13 pilares preenchidos flexo-comprimidos, cujos valores de força última são comparados com aqueles provenientes da simulação numérica via programa CFT e, os demais resultados, comentados e discutidos. Aferido, o programa CFT foi utilizado no estudo paramétrico com o intuito de avaliar a influência de parâmetros como resistência dos materiais, excentricidade da força axial, eixo de flexão e relação lado/espessura na capacidade resistente do pilar preenchido. Quanto às ligações viga-pilar, foram ensaiadas 4 tipologias de ligação, sendo duas compostas por chapas de extremidade e parafusos passantes e duas soldadas, sendo uma delas enrijecida por cantoneiras soldadas no interior do perfil tubular. Discutem-se os resultados, sobretudo quanto ao comportamento momento-rotação das tipologias investigadas. As ligações também foram investigadas via simulação numérica e os resultados obtidos permitiram elaborar diretrizes para o aprimoramento de tais simulações. Por fim, são apresentadas as conclusões pertinentes a este trabalho e recomendações para novas pesquisas / This research thesis presents a study of concrete filled steel columns subjected to combined bending and compression and beam-column connections. In both cases, tests were conducted on physical and numerical models, resulting in the development of a wide range of parametric studies for the case of the concrete filled steel columns. 13 concrete filled steel columns were tested under combined bending and compression loads whose ultimate values were compared to ultimate forces obtained from numerical simulations using the CFT computer program. After calibration, the computer program was used in the parametric study with the aim of verifying the influence of parameters, such as the material strength, eccentricity of the axial force, bending axis and breadth/thickness relation, on the ultimate load carrying capacity of the concrete filled steel columns. With respect to the beam-column connections, four types of connections were tested, two of them composed of endplate and bolts, while the other two were welded, with one of them stiffened by an angle steel placed inside the steel tube. The obtained results are discussed, giving more emphasis to the bending moment-rotation behaviour of the tested specimens. The beam-column connections were also investigated numerically. The obtained results permit the laying out of important directives for the improvement of such numerical simulation tools as the one employed in the present thesis. Lastly, pertinent conclusions relative to this thesis and recommendations for future research are presented

Page generated in 0.0381 seconds