Spelling suggestions: "subject:"way find"" "subject:"way fine""
1 |
Characterizing, Correlating, and Evaluating Swirl Flow and Heat Transfer in Wavy Plate-Fin Channels with Novel Enhancement AttributesShi, Dantong January 2020 (has links)
No description available.
|
2 |
Precision Tailoring Cooling Systems using Linear Regression / Precisionsanpassning av Kylsystem med Linjär RegressionBjelle, Kajsa, Cui, Ida January 2021 (has links)
This bachelor thesis is written for KTH Royal Institute of Technology and Ymer Technology AB. It examines the friction factor associated with the pressure drop in wavy-fin heat exchangers. Previous studies have used a nonlinear approach for determining the regression coefficients. This study introduces a linearizing transform that solves the issues of finding non-optimal parameter values stemming from the current nonlinear approach. The linearization also drastically improves the computational time. A final model explaining 95.4\% of the variance in the data is presented. Methods for avoiding overfitting, detecting outliers and hidden extrapolation are presented and used to evaluate the model. The implications of the mathematical results on improving profit, competitiveness, and customer relationships are analyzed in the second part of the report with a qualitative approach. / Denna kandidatuppsats är skrivet vid Kungliga Tekniska Högskolan och Ymer Technology AB. Det undersöker den friktionsfaktor som associeras med tryckfallet i kylare med wavy-fins. Tidigare studier har använt ett ickelinjärt tillvägagångssätt för att bestämma regressionskoefficienterna. Denna studie introducerar en linjäriserande transform som löser problemen med att hitta icke-optimala paramatervärden, som härstammar från tidigare icke-linjära tillvägagångsätt. Linjäriseringen visar sig även förbättra beräkningstiden drastiskt. En slutgiltig modell som förklarar 95\% av variansen i datan presenteras. Metoder för att undvika overfitting, identifiera outliers, och undvika att falla offer för gömd extrapolation presenteras och används för att evaluera modellen. De matematiska resultatens implikationer för Ymer med avseende på vinst, konkurrenskraft och kundrelationer, analyseras i den andra delen av rapporten med en kvalitativ ansats.
|
3 |
Influência de parâmetros geométricos no desempenho termo-hidráulico do lado do ar em serpentinas / Influence of geometric parameters on the air-side performance of air coilsSantos, Ana Carolina de Araújo Evangelista dos 08 September 2005 (has links)
O objetivo da presente pesquisa é analisar o desempenho termo-hidráulico do lado do ar de trocadores de calor tubo-aletados. Uma pesquisa da literatura foi executada em duas áreas diferentes: desempenho termo-hidráulico e seleção de superfície, feita por comparações de desempenho, para otimizar o projeto de trocadores de calor. O impulso principal da pesquisa esteve na avaliação experimental de dez serpentinas para investigar o efeito dos seguintes parâmetros sobre o desempenho do lado do ar: número de fileiras de tubos, densidade de aletas, superfície interna dos tubos e superfície da aleta (corrugada ou janelada). Os experimentos foram executados com água quente escoando internamente aos tubos em uma bancada de testes equipada com controladores que permitiram o controle exato e a medição das condições do ar e da água. As comparações com dados disponíveis na literatura para condições semelhantes revelaram que as tendências dos resultados presentes são coerentes e adequadas. Os resultados de transferência de calor e perda de carga da presente investigação não são adequadamente correlacionados por equações da literatura, sendo os desvios atribuíveis a diferenças na geometria das aletas. Finalmente, um procedimento de seleção de superfície para as aletas foi testado baseado em uma relação entre o índice de transferência de calor e a potência de bombeando. A superfície que obteve melhor desempenho entre as testadas foi a aleta janelada numa serpentina de quatro fileiras de tubos / The aim of the present research was to analyze the termo-hidraulic performance of the air side of plate-fin-and-tube heat exchangers. A literature survey has been carried out in two different areas: thermo-hidraulic performance and surface selection, done by performance comparisons, to optimize heat exchangers design. The main thrust of the research has been in the experimental evaluation of ten coils in order to investigate the effect of the following parameters over the air side performance: number of tube rows, fin density, tubes internal surface and surface fins (wavy or louvered). Experiments have been carried out with warm water as the tube fluid in a test bench with control capabilities which allowed the accurate control and measurement of air and water conditions. Comparisons with data available in the literature for similar conditions have revealed that the trends of the present results are consistent and adequate. Heat transfer and pressure drop results of the present investigation are not adequately correlated by equations from literature, deviations being attributable to differences in the geometry of the fins. Finally, a procedure for fin surface selection has been tested based on the ratio between the heat transfer rate and the pumping power. The best performing surface among the ones tested was the louver fin in a four tube row coil
|
4 |
Influência de parâmetros geométricos no desempenho termo-hidráulico do lado do ar em serpentinas / Influence of geometric parameters on the air-side performance of air coilsAna Carolina de Araújo Evangelista dos Santos 08 September 2005 (has links)
O objetivo da presente pesquisa é analisar o desempenho termo-hidráulico do lado do ar de trocadores de calor tubo-aletados. Uma pesquisa da literatura foi executada em duas áreas diferentes: desempenho termo-hidráulico e seleção de superfície, feita por comparações de desempenho, para otimizar o projeto de trocadores de calor. O impulso principal da pesquisa esteve na avaliação experimental de dez serpentinas para investigar o efeito dos seguintes parâmetros sobre o desempenho do lado do ar: número de fileiras de tubos, densidade de aletas, superfície interna dos tubos e superfície da aleta (corrugada ou janelada). Os experimentos foram executados com água quente escoando internamente aos tubos em uma bancada de testes equipada com controladores que permitiram o controle exato e a medição das condições do ar e da água. As comparações com dados disponíveis na literatura para condições semelhantes revelaram que as tendências dos resultados presentes são coerentes e adequadas. Os resultados de transferência de calor e perda de carga da presente investigação não são adequadamente correlacionados por equações da literatura, sendo os desvios atribuíveis a diferenças na geometria das aletas. Finalmente, um procedimento de seleção de superfície para as aletas foi testado baseado em uma relação entre o índice de transferência de calor e a potência de bombeando. A superfície que obteve melhor desempenho entre as testadas foi a aleta janelada numa serpentina de quatro fileiras de tubos / The aim of the present research was to analyze the termo-hidraulic performance of the air side of plate-fin-and-tube heat exchangers. A literature survey has been carried out in two different areas: thermo-hidraulic performance and surface selection, done by performance comparisons, to optimize heat exchangers design. The main thrust of the research has been in the experimental evaluation of ten coils in order to investigate the effect of the following parameters over the air side performance: number of tube rows, fin density, tubes internal surface and surface fins (wavy or louvered). Experiments have been carried out with warm water as the tube fluid in a test bench with control capabilities which allowed the accurate control and measurement of air and water conditions. Comparisons with data available in the literature for similar conditions have revealed that the trends of the present results are consistent and adequate. Heat transfer and pressure drop results of the present investigation are not adequately correlated by equations from literature, deviations being attributable to differences in the geometry of the fins. Finally, a procedure for fin surface selection has been tested based on the ratio between the heat transfer rate and the pumping power. The best performing surface among the ones tested was the louver fin in a four tube row coil
|
Page generated in 0.0585 seconds