• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 6
  • Tagged with
  • 15
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Římské lázně a saunový svět. / Roman spa - sauna world

Trávníček, Jiří January 2013 (has links)
The subject of this thesis is an architectural study of Roman spa and sauna world that connects seamlessly to a specialized atelier with theme Aquacentre - "Water Temple" Brno. The project is located to the upper floors front cupola waterpark, which is composed of monolithic reinforced concrete skeleton and its building envelope brings arched laminated wood trusses. The main task was to create the interior space. The source of inspiration was the whirlpool, which is transcribed into the design of furniture.
12

Sportovní centrum / Sports center

Kalous, Tomáš January 2014 (has links)
The theme of master´s thesis is the newly built sports center in Rychnov nad Kněžnou. The building is without a basement, two-storey, set in a slighty sloping terrain. The building is designed of system Porotherm with ceiling panels Spiroll. The roof construction is single-flat. Fitness with small sports hall, small bar, squash and wellness facilities with pool, whirlpool and sauna is located in the object. Tennis courts with training wall are outside next to the building.
13

Fitness a Wellness centrum / Fitness and Wellness center

Pospíchal, Pavel January 2018 (has links)
The diploma thesis is about design and project documentation of fitness and wellness center. The designed object is situated in the outskirts of Havlíčkův Brod in a quiet environment and with direct connection to the city dam. The object is a three-storey partially-basement building with a flat green roof in three levels. The building is based on the base passages of plain concrete, reinforced concrete slabs and beads. The supporting, peripheral and partition walls are designed from the VELOX system. The outer casing consists of cement slab, reinforced concrete core and thermal insulation. In open-plan areas there are designed reinforced concrete columns. The ceiling structure is predominantly designed from reinforced concrete slabs to lost formwork. Part of the facade is plastered, the other part is ventilated. Individual architectural elements divide the object into units and fit into the natural landscape. The object is divided into several tracts where each has its own purpose and specification. In the 1st floor there is a gym, room for trainers and coordinating training room. In the center there is atrium, reception, cloakroom, buffet and public toilets. Vertical communication is possible using a suspended staircase or a hydraulic lift. On the 1st underground floor there is a reception desk and cloakroom for disabled people. In the western part of the tract there is an indoor pool with whirlpool, of course there are cloakrooms divided for men and women. The eastern part of the tract is used as a technical room of air-conditioning, there are also 3 saunas, including a relaxation room and dressing room. All facilities on the 1st underground floor have access to an outdoor park, including a dam and outdoor whirlpools. In the 2nd floor there is a staffing facility, an area for manegement, technical rooms and an outdoor green terrace. The designed object is designed for disabled people. Around the object there is designed a car park for 33 cars.
14

Sportovně relaxační centrum v Havlíčkově Brodě / Sports relaxation centre in Havlíčkův Brod

Bočková, Veronika Unknown Date (has links)
This diploma thesis deals with a project of an sports relaxation centre in Havlíčkův Brod Ledečská street on plots no. 561/1 and 664/17 that are slightly sloping. The building is non-basement with 2 above-ground floors. The exterior load-bearing walls are made of clay blocks complemented with thermal insulation system according to ETICS. The building foundations are designes as strip foundations from concrete. Horizontal load-bearing structures will be made of prestressed concrete floor slab Spiroll. The building is roofed with a warm flat roof. First ground floor consists of sport part, there are big and small gym, crossfit excercise hall, 3 excercises halls for group lessons and 2 squash courts. It is also possible to use workout playground which is approached from the gym. There is also a buffet near the entrance. Second ground floor serves for relaxation, there are salt cave, sauna world with 5 different saunas (Finnish and also steam) and Whirlpool. The sauna world has also a cooling pool. Visitors can also use the outdoor rest area with a cooling pond. There are also a massage room, pedicure/manicure, solarium and sports shop.
15

The Biowall Field Test Analysis and Optimization

Jacob J. Torres (5930906) 14 May 2019 (has links)
<div> <p>A residential botanical air filtration system (Biowall) to investigate the potential for using phytoremediation to remove contaminants from indoor air was developed. A full scale and functioning prototype was installed in a residence located in West Lafayette, Indiana. The prototype was integrated into the central Heating, Ventilating, and Air Conditioning (HVAC) system of the home. This research evaluated the Biowall operation to further its potential as an energy efficient and sustainable residential air filtration system.<br></p> <p> </p> <p>The main research effort began after the Biowall was installed in the residence. A field evaluation, which involved a series of measurements and data analysis, was conducted to identify treatments to improve Biowall performance. The study was conducted for approximately one year (Spring 2017-Spring 2018). Based on the initial data set, prioritization of systems in need of improvement was identified and changes were imposed. Following a post-treatment testing period, a comparison between the initial and final performances was completed with conclusions based on this comparison. </p> <p> </p> <p>The engineering and analysis reported in this document focus on the air flow path through the Biowall, plant growth, and the irrigation system. The conclusions provide an extensive evaluation of the design, operation, and function of the Biowall subsystems under review.</p> </div> <br>

Page generated in 0.0425 seconds