• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 14
  • 14
  • 14
  • 13
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo topológico de escoamento trifásico óleo-água-ar através de sensor de impedância de resposta rápida do tipo \"wire-mesh\" / Topologic study of three-phase pipe flow by means of fast-response wire-mesh impedance sensor

Hugo Fernando Velasco Peña 27 February 2015 (has links)
A ocorrência frequente de escoamentos multifásicos em tubulações tem motivado um grande interesse acadêmico nas últimas décadas. O caso particular de escoamentos líquidolíquido é geralmente encontrado na indústria do petróleo, onde uma série de aplicações envolve escoamentos óleo-água, tais como a produção de petróleo e seu transporte. No entanto, ele não tem recebido a mesma atenção quando comparado com escoamentos gás-líquido. Ainda não existe uma explicação física razoável para um número significativo de fenômenos observados em escoamento óleo-água, como o fenômeno de redução de atrito, observado em escoamento disperso, e a estrutura interfacial ondulada em escoamento estratificado. Os escoamentos trifásicos têm sido ainda menos estudados. Há técnicas de medição, desenvolvidas para escoamento gás-líquido, que supostamente são adaptáveis aos escoamentos líquido-líquido, mas várias delas ainda precisam de validação adequada. O sensor wire-mesh, um método híbrido baseado na medição de resistência ou capacitância, que combina medição local intrusiva da fração de fase e imagens tomográficas transversais, oferece uma boa resolução espacial e alta resolução temporal em comparação com outras técnicas atuais. Porém, a literatura existente em aplicações do sensor wire-mesh cobre quase apenas o escoamento gás-líquido e, até agora, não é possível avaliar o limite de viscosidade do fluido para a sua aplicação. Neste contexto, este projeto propõe o estudo de aspectos importantes da fenomenologia de escoamentos líquido-líquido e líquido-líquido-gás com o auxílio da tecnologia wire-mesh. O principal objetivo prático é a validação da técnica wire-mesh como ferramenta de referência para o desenvolvimento de instrumentação para aplicações em campos petrolíferos, com especial atenção devotada ao efeito da viscosidade do óleo sobre a confiabilidade da medição e à extensão da tecnologia para lidar com escoamentos óleo-água-gás. / The frequent occurrence of multiphase flows in pipes has motivated a great research interest over the last decades. The particular case of liquid-liquid flow is commonly encountered in the petroleum industry, where a number of applications involve oil-water flow such as crude oil production and transportation. However, it has not received the same attention when compared to gas-liquid flow. There is no reasonable physical explanation for a significant number of phenomena observed in oil-water flow, as the drag reduction phenomenon observed in dispersed flow and the interfacial wavy structure of stratified flow. Much less has been investigated when it comes to three-phase flow. Several measurement techniques that are supposed to be adaptable to liquid-liquid flow have been proposed recently, but many of them still need proper validation. The wire-mesh sensor, a hybrid impedance-based method that combines intrusive local measurement of phase fraction and tomographic cross-sectional imaging, offers good spatial resolution and high temporal resolution in comparison with other current techniques. However, the existing literature on wire-mesh sensor applications covers almost only the gas-liquid flow and, so far, it is not possible to evaluate the fluid-viscosity limit for its application. In that context, this project proposes the study of important aspects of liquidliquid and liquid-liquid-gas flow phenomenology with the aid of the wire-mesh technology. The main goal is the validation of the wire-mesh technique as a reference tool for the development of instrumentation for oilfield application, with especial attention paid to the effect of oil viscosity on measurement reliability and the extension of the technology for dealing with oil-water-gas flow.
12

Versuchsanlage ROCOM zur Untersuchung der Kühlmittelvermischung in Druckwasserreaktoren - Ergebnisse quasistationärer Vermischungsexperimente

Grunwald, G., Kliem, S., Höhne, T., Rohde, U., Prasser, H.-M., Richter, K.-H., Weiß, F.-P. January 2002 (has links)
The test facility ROCOM (Rossendorf Coolant Mixing Model) has been built for the investigation of coolant mixing processes in the reactor pressure vessel of pressurised water reactors (PWR). ROCOM is a 1:5 model of the German PWR KONVOI and has been designed for a wide range of different mixing scenarios. ROCOM disposes of four loops with fully controllable coolant pumps. The test facility is operated with demineralised water. For the investigation of mixing, tracer solution (water labelled with salt) is injected into the facility. The transient distribution of the electrical conductivity is is measured at different positions of the flow path by means of wire-mesh sensor technique with high resolution in space and time. The measured conductivity is transformed into a dimensionless mixing scalar. The mixing at quasi-stationary conditions (constant loop mass flow rates) has been investigated in the presented experiments. That concerned nominal operation conditions, the operation with a reduced number of loops and the investigation of cold-water transients with running pumps and conditions of developed natural circulation. In special experimental series, the reproducibility of the results at identicla boundary conditions within the confidence intervalls has been shown. Further, the influence of various factors on the mixing has been investigated. This included the pressure losses at the core bottom plate, the global coolant flow level and the influence of the loop flow rate on the perturbed sector at the core inlet. An analysis of the measurement error of the used measurement technique completes the report.
13

3. Workshop "Meßtechnik für stationäre und transiente Mehrphasenströmungen", 14. Oktober 1999 in Rossendorf

Prasser, Horst-Michael 31 March 2010 (has links) (PDF)
Am 14. Oktober 1999 wurde in Rossendorf die dritte Veranstaltung in einer Serie von Workshops über Meßtechnik für stationäre und transiente Mehrphasenströmungen durchgeführt. Dieses Jahr kann auf auf 11 interessante Vorträge zurückgeblickt werden. Besonders hervorzuheben sind die beiden Hauptvorträge, die von Herrn Professor Hetsroni aus Haifa und Herrn Dr. Sengpiel aus Karlsruhe gehalten wurden. Erneut lag ein wichtiger Schwerpunkt auf Meßverfahren, die räumliche Verteilungen von Phasenanteilen und Geschwindigkeiten sowie die Größe von Partikeln bzw. Blasen der dispersen Phase zugänglich machen. So wurde über einen dreidimensional arbeitenden Röntgentomographen, ein Verfahren zur Messung von Geschwindigkeitsprofilen mit Gittersensoren und eine Methode zur simultanen Messung von Blasengrößen sowie Feldern von Gas- und Flüssigkeitsgeschwindigkeit mit einer optischen Partikelverfolgungstechnik vorgetragen. Daneben wurden interessante Entwicklungen auf dem Gebiet der lokalen Sonden vorgestellt, wie z.B. eine Elektrodiffusionssonde. Neue meßtechnische Ansätze waren ebenfalls vertreten; hervorzuheben ist der Versuch, die Methode der optischen Tomographie für die Untersuchung von Zweiphasenströmungen nutzbar zu machen. Der Tagungsband enthält die folgenden Beiträge: S. John, R. Wilfer, N. Räbiger, Universität Bremen, Messung hydrodynamischer Parameter in Mehrphasenströmungen bei hohen Dispersphasengehalten mit Hilfe der Elektrodiffusionsmeßtechnik E. Krepper, A. Aszodi, Forschungszentrum Rossendorf, Temperatur- und Dampfgehaltsverteilungen bei Sieden in seitlich beheizten Tanks D. Hoppe, Forschungszentrum Rossendorf, Ein akustisches Resonanzverfahren zur Klassifizierung von Füllständen W. Sengpiel, V. Heinzel, M. Simon, Forschungszentrum Karlsruhe, Messungen der Eigenschaften von kontinuierlicher und disperser Phase in Luft-Wasser-Blasenströmungen R. Eschrich, VDI, Die Probestromentnahme zur Bestimmung der dispersen Phase einer Zweiphasenströmung U. Hampel, TU Dresden, Optische Tomographie O. Borchers, C. Busch, G. Eigenberger, Universität Stuttgart, Analyse der Hydrodynamik in Blasenströmungen mit einer Bildverarbeitungsmethode C. Zippe, Forschungszentrum Rossendorf, Beobachtung der Wechselwirkung von Blasen mit Gittersensoren mit einer Hochgeschwindigkeits-Videokamera H.-M. Prasser, Forschungszentrum Rossendorf, Geschwindigkeits- und Durchflußmessung mit Gittersensoren
14

3. Workshop "Meßtechnik für stationäre und transiente Mehrphasenströmungen", 14. Oktober 1999 in Rossendorf

Prasser, Horst-Michael January 1999 (has links)
Am 14. Oktober 1999 wurde in Rossendorf die dritte Veranstaltung in einer Serie von Workshops über Meßtechnik für stationäre und transiente Mehrphasenströmungen durchgeführt. Dieses Jahr kann auf auf 11 interessante Vorträge zurückgeblickt werden. Besonders hervorzuheben sind die beiden Hauptvorträge, die von Herrn Professor Hetsroni aus Haifa und Herrn Dr. Sengpiel aus Karlsruhe gehalten wurden. Erneut lag ein wichtiger Schwerpunkt auf Meßverfahren, die räumliche Verteilungen von Phasenanteilen und Geschwindigkeiten sowie die Größe von Partikeln bzw. Blasen der dispersen Phase zugänglich machen. So wurde über einen dreidimensional arbeitenden Röntgentomographen, ein Verfahren zur Messung von Geschwindigkeitsprofilen mit Gittersensoren und eine Methode zur simultanen Messung von Blasengrößen sowie Feldern von Gas- und Flüssigkeitsgeschwindigkeit mit einer optischen Partikelverfolgungstechnik vorgetragen. Daneben wurden interessante Entwicklungen auf dem Gebiet der lokalen Sonden vorgestellt, wie z.B. eine Elektrodiffusionssonde. Neue meßtechnische Ansätze waren ebenfalls vertreten; hervorzuheben ist der Versuch, die Methode der optischen Tomographie für die Untersuchung von Zweiphasenströmungen nutzbar zu machen. Der Tagungsband enthält die folgenden Beiträge: S. John, R. Wilfer, N. Räbiger, Universität Bremen, Messung hydrodynamischer Parameter in Mehrphasenströmungen bei hohen Dispersphasengehalten mit Hilfe der Elektrodiffusionsmeßtechnik E. Krepper, A. Aszodi, Forschungszentrum Rossendorf, Temperatur- und Dampfgehaltsverteilungen bei Sieden in seitlich beheizten Tanks D. Hoppe, Forschungszentrum Rossendorf, Ein akustisches Resonanzverfahren zur Klassifizierung von Füllständen W. Sengpiel, V. Heinzel, M. Simon, Forschungszentrum Karlsruhe, Messungen der Eigenschaften von kontinuierlicher und disperser Phase in Luft-Wasser-Blasenströmungen R. Eschrich, VDI, Die Probestromentnahme zur Bestimmung der dispersen Phase einer Zweiphasenströmung U. Hampel, TU Dresden, Optische Tomographie O. Borchers, C. Busch, G. Eigenberger, Universität Stuttgart, Analyse der Hydrodynamik in Blasenströmungen mit einer Bildverarbeitungsmethode C. Zippe, Forschungszentrum Rossendorf, Beobachtung der Wechselwirkung von Blasen mit Gittersensoren mit einer Hochgeschwindigkeits-Videokamera H.-M. Prasser, Forschungszentrum Rossendorf, Geschwindigkeits- und Durchflußmessung mit Gittersensoren

Page generated in 0.0753 seconds