Cardiac procedures are the most common within the interventional radiology (IR) and they can provide high medical and occupational exposures, since, in most cases these procedures are time consuming and complexes. Although the use of X-rays is justified in this case, it is important to make an assessment of radiation doses and associated risk to patients and medical staff. The aim of this study was to build a computational model of exposure composed of an adult patient, a cardiologist and a nurse, in a typical cardiac scenario in IR and, then, estimate absorbed doses in organs and tissues, and through this dosimetric quantity, determine equivalent doses, the effective dose and cancer risk associated with exposure. The estimated dosimetric quantities were normalized by the kerma-area product (KAP). In this study, the results are presented in conversion coefficient (CC) for radiation dose and cancer risk. The radiographic parameters used in the Monte Carlo simulations were: peak voltages between 60 and 120 kVp, inherent filtration of 3.5 mm Al and a field area 10 cm x 10 cm. Eight beam projections were used: antero-posterior (AP), postero-anterior (PA), right anterior oblique (RAO90o), left anterior oblique (LAO90o), cranial (CRAN30o), caudal (CAUD30o), left anterior oblique and right anterior oblique (LAO45o and RAO45o). The radiation transport code used was MCNPX 2.7.0, in which was incorporated three anthropomorphic phantoms were incorporated with a source of X-rays emitting photons isotropically in the patient´s chest region and all common objects inside the room in IR. The anthropomorphic phantoms used to represent the cardiologist and the patient were the MASH and the nurse was simulated by the FASH phantom. Energy spectra were generated using the SRS 78 program. Two irradiation scenarios named I and II were created. In I, the operating table had no lead curtain and suspended shields of lead glass and, in II, these protection devices were considered. The average effective dose of CCs for the eight projections used in cardiac procedures angiography and coronary angioplasty was: patient 2,5E-01 mSv/Gy.cm2; cardiologist 2,0E-01(I) and 4,7E-02 ÊSv/Gy.cm2 (II) and nurse 2,4E-02 (I) and 1,8E-02 ÊSv/Gy.cm2 (II).The effective risk of cancer in 10-4/Gy.cm 2 was: 1.2 for the patient, 2,6 E-03 (I) and 4.9 E-04 (II) for the cardiologist and 5.2 E-04 (I) and 4.0 E-04 (II) for the nurse. The results presented in this study are consistent with the experimental values obtained in the literature. Thus, we believe that results improve or extend the existing data and will be a useful reference tool for professionals of radiation protection, the scientific community and especially for the physicians themselves who are exposed routinely. / Os procedimentos cardiacos sao os mais frequentes dentro da radiologia intervencionista (RI) e podem proporcionar elevadas exposicoes medicas e ocupacionais, uma vez que, na maioria dos casos, os procedimentos sao demorados e complexos. Embora o uso de raios X nestes casos seja justificado, e importante fazer uma avaliacao das doses dessa radiacao e dos riscos associados tanto em pacientes quanto nos profissionais envolvidos. O objetivo deste estudo foi criar um modelo computacional de exposicao composto por um paciente adulto, um medico cardiologista e uma enfermeira, em um cenario tipico cardiaco em RI e, posteriormente, estimar as doses absorvidas nos orgaos e tecidos e, por meio desta grandeza, determinar as doses equivalentes, a dose efetiva e os riscos de cancer associados a exposicao. As grandezas estimadas foram normalizadas pelo produto kerma-area (PKA). Os resultados obtidos estao apresentados no formato de coeficiente de conversao (CCs) de dose de radiacao e de risco de cancer. Os parametros radiograficos utilizados nas simulacoes Monte Carlo foram: tensoes de pico entre 60 - 120 kVp, filtracao inerente de 3,5 mm Al, area do campo 10 cm x 10 cm. Foram utilizadas oito projecoes de feixe: antero-posterior (AP), postero-anterior (PA), obliquo anterior direito (RAO90o), obliquo anterior esquerdo (LAO90o), cranial (CRAN30o), caudal (CAUD30o), obliquo anterior esquerdo e obliquo anterior direito (LAO45o e RAO45o). O codigo de transporte de radiacao utilizado foi o MCNPX-2.7.0, no qual foram incorporados os tres simuladores antropomorficos, uma fonte de raios X emitindo fotons isotropicamente na regiao do torax do paciente e todos os objetos comuns no interior da sala de RI. O simulador antropomorfico utilizado para representar o cardiologista e o paciente foi o MASH e para simular a enfermeira foi utilizado a FASH. Os espectros de energia foram gerados utilizando o programa SRS 78. Foram criados dois cenarios de irradiacao denominados de I e II. Em I, a mesa cirurgica nao possuia cortina de chumbo e nem tinha protetores suspensos de vidro plumbifero e, em II, estes dispositivos de protecao foram considerados. As medias dos CCs de dose efetiva para as oito projecoes usadas em procedimentos cardiacos de angiografia e angioplastia coronaria foi: paciente 2,5E-01 mSv/Gy.cm2; cardiologista 2,0-E01(I) e 4,7E-02 ÊSv/Gy.cm2 (II) e enfermeira 2,4E-02 (I) e 1,8E-02 ÊSv/Gy.cm2 (II). O risco efetivo de cancer em 10-4/Gy.cm2 foi de 1,2 para o paciente, 2,6E-03 (I) e 4,9E-04 (II) para o cardiologista e 5,2E-04 (I) e 4,0E-04 (II) para a enfermeira. Os resultados apresentados neste estudo sao consistentes com os valores experimentais descritos na literatura. Tais resultados ampliam o conhecimento ja existente sobre doses em radiologia intervencionista e propiciam uma ferramenta util de consulta para os profissionais de radioprotecao, para a comunidade cientifica e, sobretudo, para os proprios medicos que se expoem rotineiramente.
Identifer | oai:union.ndltd.org:IBICT/oai:ri.ufs.br:riufs/5295 |
Date | 18 February 2014 |
Creators | Santos, William de Souza |
Contributors | Maia, Ana Figueiredo |
Publisher | Pós-Graduação em Física |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFS, instname:Universidade Federal de Sergipe, instacron:UFS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0022 seconds