Return to search

Proposta de uma rotina de análise usando o eletrodo de diamante dopado com boro para a determinação simultânea de metais traço em água de coco

Submitted by Morgana Andrade (morgana.andrade@ufes.br) on 2016-05-31T20:19:00Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Rosa_T_R (2).pdf: 3117900 bytes, checksum: a74a7cf64102a410c59cf5b67801b905 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-06-14T18:58:57Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Rosa_T_R (2).pdf: 3117900 bytes, checksum: a74a7cf64102a410c59cf5b67801b905 (MD5) / Made available in DSpace on 2016-06-14T18:58:57Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Rosa_T_R (2).pdf: 3117900 bytes, checksum: a74a7cf64102a410c59cf5b67801b905 (MD5) / A combinação da voltametria de redissolução anódica usando onda quadrada (SWASV) com o eletrodo de diamante dopado com boro (DDB) foi proposta para a determinação simultânea de Zn, Cd, Pb e Cu livre e total em água de coco natural e industrializada. Os valores ótimos e/ou escolhidos a partir do planejamento experimental para essa técnica foram: e s para o potencial e tempo de pré-concentração; para a concentração do tampão acetato ; para o incremento do potencial; e para a amplitude de pulso e frequência. A aplicação da SWASV na amostra industrializada de água de coco I (IA), sem
digestão prévia, forneceu concentrações livres de Zn e Cu iguais a e , respectivamente. Comparando com a técnica ICP OES, essas concentrações foram 0,33 () de Zn e 1,54 () do Cu. Nesta determinação, as concentrações de Cd e Pb foram menores que os respectivos , e . Por outro lado, uma determinação da concentração total desses analitos foi obtida após uma digestão assistida por ultrassom. Neste método, foram usados da amostra de água de coco natural A, de H2O2 (37%, ) e HCl (35%, ). Após aplicação da
SWASV na amostra digerida, os valores de concentração para Zn e Cu foram 1,02 e 0,46 em relação aos valores obtidos por ICP OES. Novamente, Cd e Pb foram menores que o LD de ambas as técnicas. Alternativamente, foram realizados estudos preliminares aplicando a SWASV, com as mesmas variáveis
citadas anteriormente, porém empregando o tampão amoniacal pH 8,0 em substituição ao tampão acetato pH 4,7, para determinar a concentração dos quatro metais em uma amostra natural E (NE) digerida. Os resultados obtidos para Zn e Cu foram, respectivamente, (1,04 do ICP OES) e (, ), com destaque
para a grande sensibilidade obtida para o Cu. Ao final desses estudos, podemos constatar que o uso do eletrodo de diamante dopado com boro em conjunto com a SWASV é uma ferramenta analítica sensível e versátil, que abre novas possibilidades para a determinação de metais traço em amostras naturais e digeridas. / The square-wave anodic-stripping voltammetry (SWASV) and boron-doped diamond thin film electrode (BDD) have been proposed for the simultaneous determination of Zn, 11 Cd, Pb and Cu, free and total, in natural and processed coconut water. The optimal values and/or chosen from the experimental design for this technique were: -1500 mV; 240 s; 0.206 mol L-1; 11.56 mV; 55 mV and 100 Hz for the potential; time of deposition; concentration of acetate buffer pH 4.7; step voltage; pulse amplitude and frequency, respectively. The application of SWASV in the processed coconut water I (AI), with no previous digestion provided free Zn and Cu concentrations values of (85,8 ± 5%) and (7.7 ± 9%) μg L-1, respectively. Compared to the ICP OES technique, these concentrations were 33% (230 ± 1%, in μg L-1) of Zn and 154% (5.0 ± 10%, μg L-1) of
Cu. In this determination, the concentrations of Cd and Pb were lower than the respective LODICP OES (0.25 and 1.6 μg L-1, respectively). On the other hand, the determination of the total concentration of these analytes was carried out after digestion process assisted by ultrasound. In this method there were used 1.00 mL of natural coconut water of the sample A (NA), 0.8 mL of H2O2 (37% v/v) and 0.6 mL HCl
(35% v/v). After the application of the SWASV the concentration values of the digested sample for Zn and Cu were 102% and 46% in response to the values obtained by ICP OES. Again, Cd and Pb were lower than the LOD of both techniques. Alternatively, preliminary studies were conducted by applying SWASV with the same previously cited variables, but using pH 8.0 ammonium acetate buffer to replace the buffer with pH 4.7
to determine the concentration of the four metals in a digested natural sample E (NE). The results obtained for Zn and Cu were respectively 192.6 ± 17 μg L-1 (104% of ICP OES) and 13 ± 3 μg L-1 (), highlighting the great sensitivity obtained for the Cu. At the end of these studies we noted that the use of DDB in conjunction with SWASV is a sensitive and versatile analytical tool which opens new possibilities for the determination of trace metals in natural and digested samples.

Identiferoai:union.ndltd.org:IBICT/oai:dspace2.ufes.br:10/1942
Date31 August 2015
CreatorsRosa, Thalles Ramon
ContributorsFerreira, Ernesto Correa, Athayde, Geisamanda Pedrini Brandão, Muñoz, Rodrigo Alejandro Abarza, Ferreira, Rafael de Queiroz
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formattext
Sourcereponame:Repositório Institucional da UFES, instname:Universidade Federal do Espírito Santo, instacron:UFES
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds