Return to search

Estimativa do peso do recem-nascido por meio de medidas ultrassonograficas bidimensionais e do volume da coxa fetal / Birth weight precition by two-dimensional ultrasound measurements and fetal thigh volume

Orientadores: Cleisson Fabio Andrioli Peralta, Ricardo Barini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-27T11:44:05Z (GMT). No. of bitstreams: 1
BenniniJunior_JoaoRenato_M.pdf: 1809698 bytes, checksum: 399e6ab502353af527e35953428d5e09 (MD5)
Previous issue date: 2009 / Resumo: Introdução: Alguns estudos demonstram que a predição do peso fetal usando a volumetria dos membros fetais é mais precisa do que quando se usam medidas bidimensionais (2D). Até hoje, somente o método multiplanar foi utilizado para a volumetria dos membros fetais. Desta forma, a utilidade do método rotacional (VOCAL®) para este fim nunca foi testada. Objetivos: Avaliar as variabilidades intra e interobservadores e a concordância entre as medidas do volume da coxa fetal realizadas com os métodos multiplanar e VOCAL®. Comparar as acurácias das fórmulas com medidas do volume da coxa fetal com as acurácias das fórmulas com
medidas 2D. Comparar as acurácias das fórmulas deste estudo com as acurácias das fórmulas já publicadas. Métodos: 210 pacientes foram avaliadas, formando um grupo para gerar as fórmulas (n = 150) e um grupo para validá-las (n = 60). Os pacientes utilizados para gerar as fórmulas também foram utilizados para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Foram utilizadas análises de regressão polinomial para criar uma equação com medidas 2D, uma com o volume
da coxa fetal medido pelo método multiplanar (CoxaM) e uma com o volume da coxa fetal medido pelo método VOCAL® (CoxaV). Utilizaram-se testes t de Student pareados para comparar as acurácias das equações deste estudo com as acurácias das fórmulas já publicadas. Foram utilizadas análises proporcionais de Bland e Altman para avaliar as variabilidades intra e interobservadores e a concordância entre as medidas realizadas pelos métodos multiplanar e VOCAL®. Resultados: A diferença média percentual entre as medidas pelos métodos multiplanar e VOCAL® foi de -0,04 com limites de concordância de 95% de -8,17 e 8,09. A diferença média
percentual e os limites de concordância de 95% entre as medidas na avaliação das variabilidades intra e interobservadores foram -1,10 (-7,67 to 5,47) e 0,61 (-7,68 to 8,91) para o método VOCAL® e 1,03 (-6,35 to 8,41) e -0,68 (-11,42 to 10,06) para o multiplanar. As melhores fórmulas para cálculo do peso fetal estimado (PFE) foram: PFE = -562.824 + 11.962 x CA x CF + 0,009 x DBP² x CA² (CA: circunferência abdominal; CF: comprimento femoral; DBP: diâmetro biparietal); PFE = 1033.286 + 12.733 x CoxaM; PFE = 1025.383 + 12.775 x CoxaV. Tanto no grupo que gerou as fórmulas como no grupo utilizado para validá-las não houve diferença significativa entre as acurácias das fórmulas com medidas 2D ou tridimensionais (3D). Quando aplicadas nas pacientes deste estudo, as acurácias das fórmulas 2D e
3D já publicadas foram significativamente piores dos que as das novas fórmulas. Conclusões: Os métodos VOCAL® e multiplanar são intercambiáveis para a volumetria da coxa fetal. Possivelmente as maiores fontes de discrepâncias na estimativa do peso fetal são as diferenças fenotípicas entre as pacientes utilizadas para criar as fórmulas. Os dados deste estudo reforçam a necessidade de fórmulas específicas para cada população, independentemente do uso de medidas 2D ou 3D. / Abstract: Introduction: Some authors have demonstrated that the prediction of birth weight using fetal limb volumetry is more precise than with two-dimensional ultrasound (2DUS). To date, only the multiplanar method has been used for fetal limb volumetry, so the usefulness of the rotational technique (VOCALTM - Virtual Organ Computer- aided AnaLysis) for this purpose has never been tested. Objectives: To evaluate the repeatability, reproducibility and agreement of measurements performed with multiplanar and VOCALTM techniques for total fetal thigh volumetry. To compare the accuracies of birth-weight-predicting models with total fetal thigh volumetry with models derived from 2DUS parameters. To compare the performances of our new formulas with those of previously published equations. Methods: 210 patients were prospectively evaluated to compose a formula-generating group (n = 150) and a prospective-validation group (n = 60). The patients of the formula-generating group were also used to evaluate the repeatability, reproducibility and the agreement of the measurements of multiplanar and VOCALTM techiniques for fetal thigh volumetry. Polynomial regression analysis was performed in the formula-generating group to generate one equation with 2DUS measurements, one with fetal thigh volume measured by the multiplanar technique (ThiM) and one with fetal thigh volume obtained by the VOCALTM method (ThiV). Paired samples t-tests were used to compare the accuracies of our equations with those of previously published 2D and three-dimensional (3D) equations. Proportionate Bland and Altman analyses were performed to determine the agreement between the two methods and to evaluate intra- and inter-observer variability. Results: The mean percentage difference between measurements performed with the VOCALTM and multiplanar techniques was -0.04 and the 95% limits of agreement were -8.17 and 8.09. The mean percentage difference and 95% limits of agreement between paired measurements in the assessment of intra- and inter-observer variability were -1.10 (-7.67 to 5.47) and 0.61 (-7.68 to 8.91) for the VOCALTM technique and 1.03 (-6.35 to 8.41) and -0.68 (-11.42 to 10.06) for the multiplanar method. The formulas with the best fit for the prediction of birth weight (EFW) were: EFW = -562.824 + 11.962 x AC x FL + 0.009 x BPD² x AC² (AC: abdominal circumference; FL: femur length; BPD: biparietal diameter); EFW = 1033.286 + 12.733 x ThiM; EFW = 1025.383 + 12.775 x ThiV. For both the formula-generating and the rospective-validation groups, there was no significant difference between the accuracies of the new 2DUS and 3DUS models. When applied to our population, the accuracies of previously published 2DUS and 3DUS formulas were significantly worse than our models. Conclusions: The VOCALTM and multiplanar techniques can be used interchangeably for total fetal thigh volumetry. We believe that the greatest sources of discrepancies in estimation of birth weight are the phenotypic differences among patients used to create each of the formulas mentioned in this study. Our data reinforce the need for customized birth weight prediction formulas, regardless of whether 2DUS or 3DUS measurements are employed. / Mestrado / Tocoginecologia / Mestre em Tocoginecologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/313463
Date27 November 2018
CreatorsBennini Junior, João Renato, 1978-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Barini, Ricardo, 1955-, Peralta, Cleisson Fabio Andrioli, Bunduki, Victor
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Tocoginecologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format99 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds