Return to search

Jämförelse av värmekällor : Byte av värmekälla i ett småhus ur ett energi-, ekonomi- och klimatperspektiv

Purpose: The aim of this study is to present the economic, environmental impact, and energy saving benefits of replacing an electric boiler to a bedrock heat pump or district heating. Furthermore, the impact of additional insulation will also be presented. Method: The technical, environmental, and economical aspects of the various heat sources in this study are gathered through websites and reports from agencies, industry organisations and corporations. A case study on a family house built in 1971, heated with a combination of electric boiler and air-to-air heat pump has been made. The study investigates the impact of replacing the existing heat sources with newer and better alternatives along with additional insulation. Results: The results present the energy demand for active heating, economic analysis, environmental impact, and the impact of additional insulation. Moreover, a comparison between the heat sources and the additional insulation is presented to show the difference between them. The case study objects demand for active heating includes passive heating, heat losses through the building envelope, heat losses due to ventilation. With all these factors combined, the family house has an annual active heating demand of 11 700 kWh. The energy consumption of the electric boiler combined with air-to-air heat pump (COP 4) have an annual consumption of 7 500 kWh. The required energy from the district heating goes up to 11 700 kWh and the bedrock heat pump (COP 3) have the lowest energy consumption of 3 900 kWh. However, the amount of electricity needed is 400 kWh for district heating compared to the other alternatives that require 7 500 kWh and 3 900 kWh. For the economic aspects, the installation and operating costs for the electric boiler combined with the air-to-air heat pump, district heating and the bedrock heat pump are concluded. This shows that, on one hand the bedrock heat pump is the most expensive heat source to install but on the other hand, the cheapest to operate. Furthermore, this study compares the emissions of carbon dioxide equivalents from the production of district heating and electric energy. Due to the clean electric energy in Sweden, district heating has the highest negative impact on the greenhouse effect as it uses energy resources that have high emission of carbon dioxide equivalents. The environmental impact of the electric boiler, air-to-air heat pump and the bedrock heat pump vary depending on the energy source used to generate electricity and can in the worst case be higher than for district heating. New values with the additional insulation suggest that the improved building envelope will have a positive impact on the operation costs, energy saving and emissions. As an example, the demand for active heating can be reduced with up to 30%. Conclusions: The conclusion is that the comparison of heat sources contains many uncertain variables. Consequently, the result of this study does most likely not apply directly to other study objects. The results may vary if, for example, the geographical location or electricity agreement is changed.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:mdh-55435
Date January 2021
CreatorsGoblirsch, Amanda, Izat, Banaz, Österblad Rintanen, Melinda
PublisherMälardalens högskola, Akademin för ekonomi, samhälle och teknik
Source SetsDiVA Archive at Upsalla University
LanguageSwedish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds