The connection between the current penetration-based national ambient air quality standard and dose can be considered questionable.

Abstract

dc:description.abstract

This research examined the bias between penetration (as PM2.5) and deposition (as deposited submicrometer particulate DSP) due to the variability of ambient air particle size distributions. A size mobility particle analyzer and portable dust monitor were used to measure count and mass data at three locations in Morgantown West Virginia It was found that over 50% of the median diameters are less than 1µm. A correlation between deposition and penetration was found even though the PM 2.5 criterion is not a good indication of dose. This was due to a lack of variability in the measured distributions. Further research is needed to determine if this finding is supportable over longer time periods and larger areas.

Degree

thesis:*
Name thesis:degree_name
MS
Level thesis:degree_level
Thesis

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Berakis, Michael T.
Contributors dc:contributor
  • Dianne L. McMullin
  • Michael A. McCawley
  • Ralph W. Plummer

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Berakis, Michael T.. The connection between the current penetration-based national ambient air quality standard and dose can be considered questionable.. Thesis thesis, https://doi.org/10.33915/etd.10430