Back to search

West Virginia University

Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments

Abstract

dc:description.abstract

Abstract Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. This dissertation looks at the ongoing issue of tiny airborne particles created during medical and dental procedures and evaluates ways to reduce the risk of exposure for healthcare workers and patients to these particles. The first study focuses on the size, how long particles stay in the air, and how far they travel from common medical procedures that create aerosols, showing that tiny particles (less than 5 µm) can stay in the air long enough to escape basic droplet controls. As a transition, the second study compares three air curtain configurations, i.e., Push, Pull, and Push-Pull, in a purpose-built dual-compartment chamber and demonstrates that a well-tuned Push-Pull arrangement consistently delivers the best containment (≈95% under optimized conditions), maintains performance when modest obstructions are introduced, and outperforms single-stream designs. The third study translates the chamber results to realistic clinical rooms by applying Reynolds and Euler number as a dimensionless parameter for scaling and regression based predictions. The scaled models indicate that Push-Pull system can achieve comparable containment in full scale settings, when properly calibrated and integrated with existing ventilation. These studies show that combining targeted engineering controls with routine ventilation and personal protective equipment reduces aerosol escape from procedural zones. The studies also provide partial parameters (jet velocity, nozzle geometry, and pressure balance) to guide clinical implementation.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Occupational & Environmental Health Sciences

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mutairi, Manal
Contributors dc:contributor
  • Michael McCawley
  • Sijin Wen
  • Christopher Martin
  • Marcus Cervantes

Subjects

dc:subject × 13

Identifiers

dc:identifier.*
Identifier
<p><a href="https://orcid.org/0009-0000-4846-5809">https://orcid.org/0009-0000-4846-5809</a></p>
https://researchrepository.wvu.edu/etd/13179

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mutairi, Manal. Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. Dissertation thesis, https://doi.org/10.33915/etd.13179