Back to search

West Virginia University

Dynamic calibration of drifting sensor arrays for real-time monitoring

Abstract

dc:description.abstract

Traditional sensor calibration is restricted to mathematically relating the steady-state sensor responses to the target analyte concentrations to realize environment monitoring. However, commonly-used chemical sensors usually require a relatively long time, on the order of minutes, to reach steady-state operation, and exhibit nonlinear drifting behaviors. To achieve real-time monitoring of rapidly-changing environments while accommodating drifting behaviors, this work develops statistical methods for both forward descriptive calibration and inverse dynamic calibration of sensor arrays.;Forward calibration is performed based on experimental data. In this work, multivariate Gaussian processes (GPs) were adapted to obtain the forward calibration model, which quantifies the sensor response as a function of the analyte concentration, the drifting variables, and the sensors' exposure time. The multivariate GP method synergistically models all calibration data collected under a range of drifting conditions, and seeks to produce the calibration model of highest quality with the given experimental data. The forward calibration model is a descriptive model, relating sensors' time-dependent responses to a static environment specified by several variables, hence it is not able to assist in real-time monitoring of rapidly-changing environments.;To achieve real-time monitoring of analyte concentrations while fully utilizing the efficiency of forward calibration rendered by multivariate GPs, an inverse calibration method was developed. This inverse model takes the form of a transfer function regression, infers the time-varying analyte concentrations from the dynamic sensor responses, and thus can be coupled with sensors for real-time monitoring. The inverse transfer function model is estimated from the pseudo-calibration data generated by the forward multivariate GP model, which captures the sensors' dynamic and drifting behaviors as reflected in the real experimental data.;Simulated sensor arrays have been developed from real sensor data, and were used to demonstrate the calibration methods developed in this work.

Degree

thesis:*
Name thesis:degree_name
PhD
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Industrial and Managements Systems Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Geng, Zongyu
Contributors dc:contributor
  • Feng Yang
  • Wafik Iskander
  • Majid Jaridi
  • Natalia A Schmid
  • Nianqiang Wu

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
West Virginia University
Base URL
researchrepository.wvu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Geng, Zongyu. Dynamic calibration of drifting sensor arrays for real-time monitoring. Dissertation thesis, https://doi.org/10.33915/etd.5659