West Virginia University
Can Fitts' Throughput Be A Predictor Of Muscle Fatigue – A Study Based On Metacarpal Gloves?
Abstract
dc:description.abstractIn this study, Fitts’ throughput was used to estimate throughput for metacarpal gloves. Fitts’ throughput combines speed and accuracy during target transfer/movement tasks into a single performance index. It was hypothesized that the throughput will be affected by the glove condition and it will exhibit a relationship with the physiological response of hand muscles and perceived exertions. Fifteen healthy participants (10 males, 5 females) were recruited for data collection. Each participant performed a series of target transfer tasks using four glove conditions: (1) a pigskin leather (glove 1); (2) a synthetic fiber glove (glove 2); (3) a goat-grain leather glove (glove 3); (4) bare hand. The physiological response of hand muscles was recorded during a separate gripping study. The participants performed 60-second static gripping tasks using each glove condition at force levels of 35% of their maximum gripping strength. Surface electromyography (SEMG) was used to record activation levels of four-hand muscles: (i) Flexor Digitorum Superficialis, (ii) Flexor Carpi Radialis, (iii) Extensor Carpi Radialis Longus, and (iv) Extensor Digitorum. Glove condition had a significant effect on throughput (p<0.05). The highest throughput was observed for bare hand (3.17 bits/s), followed by Glove 3 (2.44 bits/s). High throughput signifies high accuracy and low task completion time. Glove 2 and Glove 1 had a similar throughput of 2.34 bits/s. The lowest muscle activation was observed for bare hand (51%), followed by glove 1 (59%), glove 2 (60%) and glove 3 (64%). A drop in the median frequency of SEMG data, which is an indication of muscle fatigue was significantly affected by the glove condition (p<0.05). The lowest drop was observed for bare hand (9%), followed by glove 2 (17%), glove 1 (18%) and glove 3 (23%). A similar trend was also observed for perceived exertions. Overall, the results of this study indicate that during gloved exertions, a direct relationship exists between throughput and the physiological response of hand muscles. The Fitts’ throughput holds the potential to be used as a performance measure to evaluate and compare different types of gloves.
Degree
thesis:*- Name thesis:degree_name
- MS
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Industrial and Managements Systems Engineering
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Sah, Sachin
- Contributors dc:contributor
-
- Ashish D. Nimbarte
- Eduardo Sosa
- Leily Farrokhvar
Subjects
dc:subject × 3Identifiers
dc:identifier.*- Identifier
- https://researchrepository.wvu.edu/etd/7409