• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 212
  • 150
  • 15
  • 12
  • 12
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 422
  • 111
  • 68
  • 58
  • 44
  • 39
  • 35
  • 34
  • 34
  • 33
  • 32
  • 31
  • 30
  • 27
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

The accuracy of Quick Ceph imaging software in the prediction of soft tissue profiles associated with mandibular advancements of differing magnitude

Southers, Erik Leroy. January 1999 (has links)
Thesis (M.S.)--University of Southern California, 1999. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
272

The class II skeletal syndrome a statistical and graphic investigation of vertical dimension utilizing a computer based analysis : a thesis submitted in partial fulfillment ... orthodontics ... /

Matthews, Robert E. January 1975 (has links)
Thesis (M.S.)--University of Michigan, 1975.
273

Condylar growth and function of the lateral pterygoid and superficial masseter muscles in the rat this thesis submitted in partial fulfillment ... in orthodontics ... /

Easton, Jeffrey Waldemar. January 1987 (has links)
Thesis (M.S.)--University of Michigan, 1987.
274

Need for orthodontic treatment with special reference to mandibular dysfunction a study in men and women /

Mohlin, Bengt. January 1982 (has links)
Thesis (doctoral)--University of Göteborg, 1982. / Extra t.p. with thesis statement inserted. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
275

Mandibular reconstruction /

Häfner, Stephan Georg. January 2009 (has links)
Diss. med. dent. Zürich. / Literaturverz.
276

Dependence of craniofacial growth on stages of cervical vertebral maturation and stages of mandibular canine mineralization

Chance, Charles Allen, January 2006 (has links) (PDF)
Thesis (M.S.)--University of Tennessee Health Science Center, 2006. / Title from title page screen (viewed on October 8, 2007 ). Research advisor: Edward Harris, Ph.D. Document formatted into pages (xiii, 156 p. : ill.) Vita. Abstract. Includes bibliographical references (p. 137-147).
277

Συγκριτική βιο-μηχανική μελέτη οστεοσύνθεσης καταγμάτων γωνίας κάτω γνάθου με χρήση εύκαμπτων τριών διαστάσεων (3D) πλακών οστεοσύνθεσης με αντίστοιχες κλασικές / Comparative biomechanical evaluation of three diamensional (3D) miniplates with classic osteosynthesis systems in mandibular angle fractures.

Καλφαρέντζος, Ευάγγελος 13 July 2010 (has links)
H θεραπεία των καταγμάτων της γωνίας της κάτω γνάθου είναι αμφιλεγόμενη και παραμένει ένα θέμα διαρκούς αντιπαράθεσης στη διεθνή βιβλιογραφία. Οι τρισδιάστατες μίνι πλάκες (3D) είναι σχετικά καινούργιες και υποστηρίζεται ότι εμφανίζουν βελτιωμένη μηχανική συμπεριφορά, χωρίς όμως να υπάρχουν βιβλιογραφικά δεδομένα ή κλινικές έρευνες που να υποστηρίζουν τη χρήση τους. Σκοπός της μελέτης αυτής είναι να αξιολογηθούν δύο τρισδιάστατα μίνι συστήματα οστεοσύνθεσης και να συγκριθούν με αντίστοιχα κλασικά συστήματα μίνι πλακών που χρησιμοποιόυνται ευρέως στην κλινική πράξη. Υλικό-Μέθοδος: Συνθετικές κάτω γνάθοι χρησιμοποιήθηκαν για την αξιολόγηση των τρισδιάστατων συστημάτων οστεοσύνθεσης, σε σύγκριση με τέσσερα ακόμα συστήματα. Οι ομάδες μελέτης ήταν οι εξής: Ομάδα 1 Mία 3D μίνι πλάκα2x2 οπές, τετράγωνη 2.0mm Ομάδα 2 Mία 3D μίνι πλάκα4x2 οπές, ορθογώνια, 2.0mm Ομάδα 3 Σύστημα δύο πλακών, 4 οπές, ευθείες, 2.0mm & 1.6mm Ομάδα 4 Mια μίνι πλάκα, 4 οπές, ευθεία με διάστημα, 2.0mm Ομάδα 5 Σύστημα δύο πλακών, 4 οπές, ευθείες, 2.0mm & 1.6mm Ομάδα 6 Μια πλάκα κατάγματος (fracture plate) 6 οπές, γωνία 140ο, 2.0mm Κάθε ομάδα υποβλήθηκε σε φόρτιση στην πρόσθια τομική περιοχή και στην σύστοιχη με το κάταγμα γομφιακή περιοχή, μέσω ενός μηχανήματος εφαρμογής τάσης (Monsanto Tensometer 20). Έγινε μέτρηση και καταγραφή του κενού στο άνω όριο του κατάγματος καθώς επίσης και μετρήσεις τιμών ακαμψίας (stiffness) για κάθε τύπο φόρτισης ξεχωριστά. Υπολογίστικαν οι μέσες τιμές και οι σταθερές αποκλίσεις των παραπάνω τιμών και ακολούθως έγινε στατιστική ανάλυση των αποτελεσμάτων με χρήση του απλού t-test. Στατιστικά σημαντικά θεωρήθηκαν αποτελέσματα με p< 0,05 %. Αποτελέσματα: Κατά τη φόρτιση της ομόπλευρης προς το κάταγμα γομφιακής περιοχής η στατιστική ανάλυση ανέδειξε στατιστικά σημαντικές διαφορές μεταξύ των ομάδων. Κατά τη φόρτιση της πρόσθιας τομικής περιοχής δεν αναδείχθηκαν στατιστικά σημαντικές διαφορές. Το κενό στο άνω χείλος του κατάγματος ήταν οριακό σε τέσσερα από τα συστήματα που εξετάστηκαν. Συμπεράσματα: Με βάση το πειραματικό μοντέλο που χρησιμοποιήθηκε η ομάδα 1 (τετράγωνη 3D) εμφάνισε την καλύτερη εμβιομηχανική συμπεριφορά. / Therapy of mandibular angle fractures is controversial and is still a subject of continuous interest in international literature. Three dimensional (3D) mini plates are relatively new, with no biomechanical or clinical studies to support their use. The aim of this study is to comparatively evaluate the use of two 3D mini plating systems for the treatment of mandibular angle fractures, with mini plates used in ordinary clinical practice. Materials and Methods: Synthetic mandible replicas were used to evaluate the effectiveness of the 3D plates along with four other mandibular angle plating techniques. The plating techniques consisted of: 1. A 3D miniplate (2x2 holes, square, 2mm) 2. A 3D miniplate (6x2 holes, curved, 2mm) 3. Two plate system (four hole, straight, 2mm,placed at the lateral oblique ridge and 1,6mm) 4. One single miniplate (four hole, straight, 2mm) 5. Two plate system (four hole, straight, 2mm,placed in the buccal aspect of the lateral oblique ridge and 1,6mm) 6. A fracture plate (six hole, curved). Each group was subjected to incisal and homolateral molar region loading by a tensile materials testing machine (Monsanto Tensometer 20). Load stiffness values and peak measurements of the fracture gap distraction at the superior aspect of the mandible were measured. The mean values (± standard deviation) were derived and compared using students t-test, with statistical significance set at p<0.05. Results: For homolateral molar loading, statistically significant differences existed within groups (P<0, 05). For incisal edge loading, no statistically significant differences were found for stiffness among the fixation methods tested. Gap distraction at the superior aspect of the mandible was limited for four of the groups tested. Conclusion: Under the conditions tested the 3D square plate system provided the most favourable mechanical behaviour.
278

Sistema de captação de imagens para avaliação dos movimentos biomecânicos das articulações temporomandibulares

Carvalho, André Solon de [UNESP] 08 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08Bitstream added on 2014-06-13T18:57:58Z : No. of bitstreams: 1 carvalho_as_me_guara.pdf: 714165 bytes, checksum: a9b78d56635122098c45b1b30722ec8f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Abrir e fechar a boca é um dos movimentos biomecânicos mais importantes do ser humano, sendo um dos primeiros a ser realizado antes mesmo do nascimento. Ela é responsável pela deglutição, mastigação, respiração e a fala. Este movimento é realizado por um conjunto articular-músculo-esquelético, chamado sistema estomatognático, no qual destaca a mais complexa articulação do corpo humano, denominada de articulação temporomandibular (ATM). Sua disfunção acarreta uma série de problemas sempre acompanhada de dores, no qual grande parte da população mundial apresenta distúrbios neste sistema, necessitando a busca de tratamento. Apesar de estudos já realizados, torna-se ainda imprescindível uma abordagem específica do tema, no qual a ausência de parâmetros existentes, e mundialmente aceitos, para avaliações e diagnósticos, comprometem os objetivos do tratamento, que atualmente depende mais da experiência do terapeuta do que de evidências científicas. Desta forma este trabalho contribui para obtenções de conhecimentos, esclarecimentos e cuidados com pacientes que sofrem de Disfunção Temporo Mandibular (DTM), com o seu principal objetivo, a construção de um equipamento capaz de mensurar e diagnosticar anormalidades durante o movimento biomecânico da abertura e fechamento da boca, através de um sistema de captação de imagens. Utiliza-se de equipamentos de baixo custo e de fácil manuseio, comparado a sistemas disponíveis hoje no mercado. As imagens obtidas são processadas por um software específico para este fim, onde os dados são tratados e modelados, fornecendo o movimento no plano frontal e lateral da mandíbula, analisando sua respectiva trajetória no movimento de lateralidade, protrusão e amplitude máxima da abertura e fechamento da boca, fornecendo dados milimetricamente mensurados.... / To open and to close the mouth are one of the more important biomechanics movements of the human being, being one of first to be carried through before the same one of the birth. It is responsible for the deglutition, chew, breath and he says it. This movement is carried through by a joint articulate-muscle-bone, call masticate system, in which detaches the most complex joint of the called human body of Joint Temporo Mandible (JTM). Its disturb causes a series of problems always followed of pains, needing the treatment search. Although some carried through studies already, a specific boarding of the subject still becomes essential, in which the absence of existing parameters, and world-wide accepted, and diagnostic, compromises the objectives of the treatment, that currently depends more on the experience of the therapist on whom of scientific evidences. Of this form this work search the attainment of knowledge, clarifications and cares with the patients who suffer DTM, having as objective to construct an equipment capable to measure and to diagnosis abnormalities during the biomechanics movement of the opening of the mouth, through a system of capitation of images. One today used of equipment of low cost, compared the available systems in the market, generating images that will be processed for a software, developed specifically for this work, for the treatment and modeling of the data of the movement in the front plain of the jaw, analyzed its respective trajectory, in the movement of lateral, supplying given measure ...(Complete abstract, click electronic address below).
279

Avaliação de doses referenciais e acurácia de mensurações lineares obtidas em exames de tomografia computadorizada de feixe cônico adquiridos com diferentes tamanhos de voxel

Torres, Marianna Guanaes Gomes January 2009 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-24T13:10:47Z No. of bitstreams: 1 DISSERTACAO - Marianna Torres.pdf: 3737774 bytes, checksum: dc2fecaa530f7b5bc4c0f507fbe6a184 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:48:36Z (GMT) No. of bitstreams: 1 DISSERTACAO - Marianna Torres.pdf: 3737774 bytes, checksum: dc2fecaa530f7b5bc4c0f507fbe6a184 (MD5) / Made available in DSpace on 2013-05-08T11:48:36Z (GMT). No. of bitstreams: 1 DISSERTACAO - Marianna Torres.pdf: 3737774 bytes, checksum: dc2fecaa530f7b5bc4c0f507fbe6a184 (MD5) Previous issue date: 2009 / A tomografia computadorizada de feixe cônico (TCFC) apresenta voxel reduzido, quando comparada à tomografia computadorizada convencional. Além disso, alguns aparelhos permitem a variação do tamanho do voxel para aquisição de imagens. Em geral, quanto menor o tamanho do voxel, melhor será a resolução. No entanto, para o aparelho i-CAT, por exemplo, um voxel menor está atrelado a um tempo de varredura mais longo, o que proporciona algumas desvantagens como maiores possibilidades de movimentação do paciente durante o exame e doses mais elevadas de radiação. Este trabalho tem como objetivo avaliar doses referenciais – produto dose-área (PDA) e dose de entrada na pele (DEP) – e acurácia de mensurações lineares feitas na mandíbula através de imagens de TCFC adquiridas com diferentes tamanhos de voxel, a fim de estabelecer o melhor protocolo a ser utilizado para realização de mensurações lineares. Oito mandíbulas secas foram submetidas a exames de TCFC, usando o aparelho i-CAT, a partir de quatro protocolos, a saber: p1) voxel de 0,2mm, 40seg e 46,72mAs; p2) voxel de 0,25mm, 40seg e 46,72mAs; p3) voxel de 0,3mm, 20seg e 23,87mAs; p4) voxel de 0,4mm, 20seg e 23,87mAs. A quilovoltagem permaneceu constante (120kVp). Para avaliação da acurácia das mensurações lineares, cortes tomográficos com visualização mais central dos marcadores, colocados em seis sítios em cada mandíbula, foram selecionados para realização de medidas verticais e horizontais, com o auxílio da ferramenta de mensuração de linha do Xoran (software do i-CAT). Os valores obtidos das mensurações diretas na mandíbula seca, com uso do paquímetro digital, após secção das mesmas nos sítios pré-estabelecidos, e das mensurações nas imagens tomográficas foram comparados e o erro de mensuração (EM) calculado. Para avaliação das doses referenciais, a medição do DEP foi realizada através do uso de uma câmara de ionização do tipo lápis e para o PDA foi utilizado um aparelho PTW, nos quatro protocolos. Na avaliação da acurácia das mensurações lineares, não houve diferença significativa entre o EM dos protocolos, o que mostra que eles se comportaram iguais quanto à realização de medidas lineares. O EM foi bastante reduzido, uma vez que a média da diferença entre os valores obtidos nas imagens e na mandíbula seca foi menor do que 1mm para todos os protocolos e, em sua grande maioria, sofreram variação para menos. Para avaliação das doses referenciais, detectou-se diferença estatisticamente significante (p<0,001) entre os protocolos, para avaliação do PDA e DEP, sendo que os protocolos p3 e p4 apresentaram doses significantemente menores. A diferença significativa presente entre os protocolos está diretamente relacionada à diferença da miliamperagem e do tempo de varredura. Sendo assim, o uso dos protocolos p3 e p4 devem ser, preferencialmente, indicados na avaliação de mensurações lineares, uma vez que a dose de radiação é significantemente menor quando comparado aos protocolos p1 e p2, sem perda de acurácia das mensurações verticais e horizontais. / Salvador
280

Avaliação da anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico em uma população brasileira / Evaluation of mandibular anatomy and its variations by cone beam computed tomography in a brazilian population

Cunha, Rodrigo Montezano da January 2016 (has links)
O conhecimento da localização, bem como da configuração das estruturas anatômicas presentes na mandíbula e suas respectivas variações são extremamente importantes para o planejamento de procedimentos cirúrgicos que envolvam este osso. O presente estudo teve como objetivo avaliar a anatomia mandibular e suas variações por meio da tomografia computadorizada de feixe cônico (TCFC) em uma população brasileira. Foram utilizados 1254 exames de TCFC realizados no equipamento I-Cat Next Generation, (Imaging Sciences International®) sob um protocolo com voxel de 0,2 mm, FOV amplo (16cm x 13cm) e tempo de escaneamento de 40 segundos. Três examinadores treinados e calibrados avaliaram os exames por meio do software I-Cat Vision (Imaging Sciences International®). Os dados que foram coletados em um formulário Access (Microsoft® Office) e analisados para prevalência, também foram correlacionados, isolando as variáveis gênero e situação dentária (dentado total, dentado parcial e desdentado total. Os resultados de prevalência foram: forame mentual localizado entre o 1º e 2º pré-molar inferior (91,38%), alça anterior (12,57%), canais acessórios (40%), canal mandibular bífido (CMB) (22%) e canal mandibular corticalizado (33,84%). O canal mandibular, em toda sua extensão, está localizado mais para vestibular nas mulheres, com diferença estatisticamente significante entre gêneros (P=0,002). Não foi encontrada diferença na distância V-L na região de fóvea submandibular entre os gêneros. Os CMBs não tem predileção por gênero (P=0,186), havendo diferença estatisticamente significante entre os tipos (P=0,001), sendo o Retromolar o mais frequente. O uso dos exames de TCFC permitiu identificar características anatômicas mandibulares importantes em uma população brasileira, sugerindo que essas devam ser investigadas antes de intervenções cirúrgicas. / The knowledge of the location, as well as the configuration of the anatomical structures and their respective variations are extremely important for the planning of surgical procedures involving this bone. The aim of this study was evaluate the mandibular anatomy and its variations through Cone Beam Computed Tomography (CBCT) in a Brazilian population. A total of 1254 CBCT scans were performed on the I-Cat Next Generation (Imaging Sciences International®) equipment under a protocol with 0.2 mm voxel, wide FOV (16cm x 13cm) and 40 seconds scanning time. Three trained and calibrated examiners evaluated the exams using I-Cat Vision software (Imaging Sciences International®). The data that were collected in Access form (Microsoft® Office) and analyzed for prevalence. In line, were correlated with gender. The prevalence results were: mental foramen located between the 1st and 2nd lower premolars (91.38%), anterior loop (12.57%), accessory canals (40%), bifid mandibular canal (BMC) (22%) and corticalized mandibular canal (33.84%). The mandibular canal, in all its extension, is located more for vestibular in the women, with statistically significant difference between genders (P = 0,002). There is no difference in V-L distance between genders in submandibular fovea area. The BMCs do not have a gender preference (P = 0.186). However, there is a statistically significant difference between the types (P = 0.001), and Retromolar is the most frequent. The use of CBCT scans allowed the identification of important mandibular anatomical features in a Brazilian population, suggesting that these should be investigated before surgical interventions.

Page generated in 0.0328 seconds