• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 189
  • 33
  • 13
  • 7
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 563
  • 170
  • 118
  • 82
  • 77
  • 72
  • 68
  • 48
  • 44
  • 41
  • 39
  • 38
  • 37
  • 36
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Modelagem numerica por elementos de contorno 3D de juntas coladas em estruturas aeronauticas de material composito / Numerical modeling of bonded joints in aircraft structures of composites material using 3D boundary element method

Souza, Carlos Alexandre Oliveira de 14 August 2018 (has links)
Orientadores: Paulo Sollero, Eder Lima de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T09:46:04Z (GMT). No. of bitstreams: 1 Souza_CarlosAlexandreOliveirade.pdf: 3303337 bytes, checksum: beed7bb6d99b6ae8f528600efe197f82 (MD5) Previous issue date: 2009 / Resumo: Na indústria aeronáutica é comum o uso de juntas coladas, rebitadas e parafusadas na união de componentes ou partes estruturais. O projeto de juntas coladas é baseado em análise para a determinação das tensões normais e cisalhantes no adesivo e do campo de deslocamentos ao longo da junta. O objetivo deste trabalho é desenvolver uma ferramenta computacional, utilizando o software Matlab® para resolver numericamente o problema de juntas coladas sobrepostas (lap joints) de material compósito no contexto 3D. O método numérico empregado para a resolução das equações diferenciais que regem o problema é o Método dos Elementos de Contorno (MEC) e a Técnica das Sub-Regiões. Para a implementação são considerados elementos retangulares constantes e descontínuos, isto é, os elementos não compartilham graus de liberdade. É utilizada nesse trabalho a Solução Fundamental para Anisotropia plena obtida por meio da Transformada de Radon que já foi anteriormente implementada por Santiago (2008). Além da Solução Fundamental Anisotrópica, também é implementada uma função contendo a Solução Fundamental Isotrópica com o objetivo de validar o código através de resultados analíticos disponíveis na literatura para este caso. / Abstract: The use of bonded, riveted and bolted joints to assemble components or structural parts is inevitable in aeronautic industries. The design of bonded joints is based upon analyses to estimate peeling and shear stresses in the adhesive and the displacement field along the bonded region. The objective of this work is to develop a computational tool using the Matlab® software to solve numerically the bonded lap joints problem in composite materials for aeronautical structures in 3D context. The numerical method to be employed for solving governing differential equations is the Boundary Element Method (BEM) and Sub-Regions Technique. For this implementation, rectangular constants and discontinuous elements were considered, which means that nodes don't share degrees of freedom. In this work is used the Fundamental Solution for Anisotropy obtained by Radon transform which was previously implemented by Santiago (2008). Besides the Anisotropic Fundamental Solution, also is implemented a function containing the Isotropic Fundamental Solution with the objective of validating the code with analytical results available in literature for this case. / Universidade Estadual de Campi / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
362

Efeito do digluconato de clorexidina na estabilidade da união de sistemas adesivos e dentina sadia ou afetada por carie / Effect of clorhexidine digluconate on the bond strength of etch-and-rinse adhesives to normal/caries-affected dentin

Komori, Paula Carolina de Paiva 15 February 2007 (has links)
Orientadores: Marcela Rocha de Oliveira Carrilho, Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T07:24:11Z (GMT). No. of bitstreams: 1 Komori_PaulaCarolinadePaiva_M.pdf: 1172692 bytes, checksum: f270e64b5e17566b769c732de50975bf (MD5) Previous issue date: 2007 / Resumo: O objetivo deste trabalho foi avaliar o efeito da aplicação da solução aquosa de digluconato de clorexidina a 2% (CHX) na estabilidade da união de sistemas adesivos convencionais e dentina sadia (DS) ou afetada por cárie (DAC). Neste estudo foram testadas as hipóteses de que a CHX não teria efeito prejudicial na resistência de união entre DS ou DAC e que em longo prazo a CHX poderia minimizar o mecanismo de degradação da interface dentina-resina. Vinte molares humanos cariados tiveram o esmalte e dentina superficial removidos para exposição de uma superfície plana de DS e DAC. Os substratos foram condicionados com gel de ácido fosfórico 35% por 15s, lavados e secos com leve jato de ar. Os dentes foram distribuídos em dois grupos para o tratamento da superfície dentinária, o controle: foi re-umedecido com água deionizada; e o experimental: com CHX, a solução umidificadora permaneceu em contato com o substrato durante 60s e o excesso de umidade removido com papel absorvente. Sobre o substrato foi aplicado o adesivo Scotchbond Multi-Purpose (MP) ou Single Bond 2 (SB) e confeccionado um bloco com incrementos de resina composta Z-250. Após 7 dias de armazenagem em solução fosfato tamponada (PBS, pH 7,4) a 37ºC, as amostras foram submetidas a cortes seriados, gerando espécimes em forma de palitos com área de interface de união de aproximadamente 0,8mm2. Metade dos espécimes foi imediatamente submetida ao teste de microtração e a outra metade permaneceu armazenada por 6 meses. Os resultados obtidos foram submetidos à análise de variância e teste de Holm-Sidak para contraste das médias em nível de significância (a=0,05). A primeira hipótese testada foi confirmada, o uso da CHX após o condicionamento ácido não interferiu na resistência mecânica imediata da interface formada por um compósito de resina e DS ou DAC. A segunda hipótese foi parcialmente confirmada, o uso da CHX após o condicionamento ácido minimizou o processo de degradação das interfaces de união constituídas por DS. A utilização da CHX em associação aos sistemas adesivos convencionais de 2 e 3 passos durante a hibridização pode atuar como potencial agente retardador da degradação das interfaces adesivas promovendo maior longevidade às restaurações adesivas / Abstract: The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate on the bond strength of etch-and-rinse adhesives applied to sound (SD) and caries-affected dentin (CAD). It is hypothesized that CHX does not have a detrimental effect on the bond strength to sound and caries-affected dentin, as well as that CHX may decelerate the mechanical degradation of resin-dentin bonds over time. Twenty, carious, extracted molars were included in this study. The occlusal enamel of all teeth was removed with a slowspeed diamond saw, under copious water-cooling, in order to expose a flat surface, where the CAD was surrounded by SD. The CAD and SD surfaces were etched with 35% phosphoric acid gel for 15 s, rinsed for 30 s with tap water and dried with oil/water-free air. In the control groups, the dentin substrates were re-hydrated with distilled water, while in the experimental groups were re-hydrated with 2 wt% chlorhexidine digluconate (CHX). After a dwell time of 60 s, excess solution was removed with absorbent paper. The dentin surfaces were then bonded with one of the etch-and-rinse adhesives, Schotchbond Multi- Purpose (MP) or Single Bond 2 (SB). Composite build-up was performed with Z250 and stored in phosphate-buffered saline (PBS, pH 7.4) at 37ºC for 7 days. After this period, the restored teeth were longitudinally sectioned across the bonded interface to produce a series of 0.8 mm2 beams. Part of those specimens was immediately subjected to a microtensile test. The remaining specimens were stored in PBS at 37°C for six months and then tested in tension under the same protocol. Data were analyzed by ANOVA and Holm-Sidak test for multiple comparisons (a = 0.05). The first anticipated hypothesis was confirmed, the use of CHX after acid-etching did not have detrimental effect on the immediate bond strength to both normal and caries-affected dentin and the second anticipated hypothesis was partially confirmed, the mechanical degradation of resin-dentin bonds may be delayed by the application of chlorhexidine (CHX) to sound dentin after phosphoric acid-etching. Attempts to use chlorhexidine adjunctively with conventional acid-and-rinse adhesives may play a clinically-relevant role on the preservation of resin-dentin bonds / Mestrado / Mestre em Materiais Dentários
363

Efeito do fluor de um sistema adesivo na resistencia de união e no desafio acido em dentina / Effect of fluoride containing adhesive system on microtensile bond strength and acid challenge on dentin

Shinohara, Mirela Sanae 28 February 2007 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T05:02:58Z (GMT). No. of bitstreams: 1 Shinohara_MirelaSanae_D.pdf: 3018873 bytes, checksum: 16d55d49d5fce271495b768e34d15abc (MD5) Previous issue date: 2007 / Resumo: Apesar do avanço na odontologia adesiva, não é possível conseguir uma união perfeita da resina composta ao substrato dental. Diversos são os adesivos dentinários atualmente presentes, mas nenhum é capaz de impedir a infiltração marginal, degradação e formação de cárie secundária na interface dente-resina ao longo do tempo. Dessa forma, como alternativa, o flúor foi incorporado a um adesivo com o objetivo de promover uma ação antibacteriana e impedir a formação de cárie secundária, conseqüentemente aumentar a longevidade da restauração. Portanto, este estudo teve como objetivos: (1) avaliar a influência do flúor presente no adesivo na resistência de união em dentina e analisar a estrutura da interface dente-adesivo após desafio ácido por meio de microscopia eletrônica de varredura (MEV); (2) avaliar a influência do flúor no adesivo na resistência de união em dentina após 24 horas e 3 meses de estocagem de água, observar a formação de uma zona ácido-resistente na interface dentina-resina após 24 horas e 3 meses de estocagem em água por meio de microscopia de luz polarizada (MLP), e comparar o grau de conversão do adesivo que contém flúor com dois adesivos sem flúor após 24 horas, 1 semana e 1 mês. Tanto para o teste de resistência à microtração, como para análise das interfaces: terceiros molares humanos hígidos recém-extraídos foram usados para realização das restaurações, de acordo com os grupos analisados em cada estudo específico. Para a análise do grau de conversão, pastilhas dos adesivos foram preparados em temperatura controlada e atmosfera de nitrogênio para análise de espectrofotômetria de infravermelho pela técnica transformada de Fourier em modo de transmissão (FTIR). Os resultados mostraram que o flúor presente no adesivo apresenta um efeito positivo na resistência de união, embora apresente menor grau de conversão comparado aos adesivos sem flúor. As imagens de MEV e MLP mostraram que o adesivo com flúor forma uma zona de inibição adjacente à camada híbrida após desafio ácido / Abstract: Despite of the advance in adhesive dentistry, it is not possible to achieve an ideal bonding between composite resin and dental substrate. Currently, a variety of adhesive systems have been used. However, any adhesive system is capable to hamper the marginal leakage, degradation, and secondary caries formation at dentin-resin interfaces in long-term. For that reason, as an alternative, fluoride was incorporated in adhesive in order to promote an antibacterial action and to impede the secondary caries formation, onsequently increasing the longevity of restoration. Thus, the objectives of this study were: (1) to evaluate the influence of a fluoride-containing adhesive on the microtensile bond strength (µTBS) in dentin, and to analyze the ultra-structure of the dentin-adhesive interface after acid challenge; (2) to evaluate the influence of fluoride-containing adhesive on µTBS after 24 hours and 3 months waterstorage; to observe an acid-resistant zone at resin-dentin interface using polarized light microscopy (PLM) after 24 hours and 3 months water storage, and to compare the degree of conversion of fluoride-containing adhesive with non-fluoride containing adhesives after 24 hours, 1 week, and 1 month. For both, to the µTBS test and to analyze the ultra-structure of interfaces: free-caries human third molars were used for restorations, in accordance with of the analyzed groups in each specific study. In order to measure the degree of conversion, chips of adhesives were prepared at a constant temperature and in a nitrogen atmosphere for the analysis at Fourier Transform-Raman spectroscopy (FTIR). The results showed that the present fluoride-containing adhesive has a positive effect in bonding strength, although the lower degree of conversion compared with non-fluoride adhesives. The photomicrographs of SEM and PLM demonstrated that fluoride-containing adhesive allow the formation of an inhibition zone adjacent to the hybrid layer after acid challenge / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
364

Desempenho clinico e mecanico de adesivo auto-condicionante a dentina decidua afetada por carie / Clinical and mechanical performance of self-etching adhesive to primary caries-affected dentin

Aratani, Monica 14 February 2007 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:07:57Z (GMT). No. of bitstreams: 1 Aratani_Monica_M.pdf: 1204814 bytes, checksum: 89f8098c0a4f04da2cbe17fab1476c17 (MD5) Previous issue date: 2003 / Resumo: O propósito deste trabalho foi estudar o efeito de métodos de contensão da mufla metálica (grampo convencional e sistema RS de contensão) e do tempo pós-prensagem (imediato e 6 horas) nos níveis de adaptação da base de prótese total superior confeccionada com as resinas acrílicas ativadas termicamente Clássico (Clássico) e QC-20 (Dentsply). Foram confeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 8 grupos (n=10), de acordo com os métodos de contensão de mufla metálica e do tempo pós-prensagem. As resinas acrílicas foram proporcionadas e manipuladas de acordo com as instruções dos fabricantes e prensadas na fase plástica, com carga inicial de 850 kgf e final de 1250 kgf em prensa hidráulica de bancada. As bases confeccionadas em resina Clássico foram polimerizadas em ciclo de água a 74?C por 9 horas e as bases de resina QC-20 em água em ebulição por 20 minutos. Depois de esfriadas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionadas em três secções, correspondentes à distal de caninos, mesial de primeiros molares e região palatina posterior. Em cada secção, o desajuste entre modelo de gesso e base de resina foi verificado nos pontos referenciais fundo de sulco vestibular direito e esquerdo, crista do rebordo alveolar direito e esquerdo e linha mediana palatina posterior, com microscópio comparador linear Olympus, com precisão de 0,0005 mm. Os resultados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). O dispositivo RS produziu níveis médios de adaptação com diferença estatística significante quando comparado com o grampo convencional, independente dos demais fatores. O dispositivo RS produziu níveis médios de adaptação nos tempos imediato e 6 horas com diferença estatística significante quando comparado com o grampo convencional. A polimerização imediata produziu valores entre cortes sem diferença estatística significativa quando comparada com a polimerização após 6 horas. Quando os cortes foram analisados no fator prensagem, os melhores níveis de adaptação foram obtidos com o dispositivo RS, com diferença estatística significativa quando comparado com o grampo convencional. Os tratamentos RS e convencional apresentaram comportamento semelhante, independente da resina, mas foram diferentes no tempo pós-prensagem. A região posterior apresentou maiores valores de desadaptação em ambas as resinas, independente do tipo de contensão da mufla e do tempo pós-prensagem / Abstract: The purpose of this study was to verify the effect of flask closure method (conventional clamp and RS tension system) and post-pressing time (immediate and after 6 hours) on the maxillary denture base adaptation made with Classico and QC-20 heat?cured acrylic resins. Eighty maxillary stone cast/wax base sets were made and randomly assigned into 8 groups (n=10) according to the flask closure method and post- pressing time. The acrylic resins were proportioned and manipulated following the manufacturer?s instructions and flask pressed in the doughlike stage with an initial load of 850 kgf and final load of 1,250 kgf in hydraulic press. Classico acrylic resin was submitted to polymerization in water at 74°C during 9 hours in immediate or after 6 hour post-pressing times. QC-20 acrylic resin was submitted to polymerization in boiling water for 20 minutes. After bench cooling the resin bases were deflasked, finished, and fixed on the casts with instantaneous adhesive. The cast-resin base sets were laterally sectioned in the regions corresponding to the distal of canines (A), mesial of first molars (B), and posterior palatal zone (C). The gap between the stone cast and resin base was measured with an Olympus comparative microscope with accuracy of 0.0005mm at five referential points for each section. Data submitted to ANOVA and Tukey?s test (5%) showed that the RS system produced medium levels of adaptation with statistically significant difference when compared to the conventional clamp, independent of the other factors. RS system produced levels of adaptation in the immediate and 6 hours post-pressing times with statistical significant difference when compared to the conventional clamp. The immediate polymerization produced values among cuts without statistical difference when compared to the polymerization after 6 hours. When the cuts were analyzed in the factor flask pressure method, the best levels of adaptation were showed with the RS system, with statistical significant difference when compared to the conventional clamp. The RS system and conventional clamp treatments showed similar results independent of the resin factor; however they were different in the post-pressing time. The posterior region showed greater values of desadaptation in both resins, independent of the flask closure method and post-pressing time / Mestrado / Doutor em Materiais Dentários
365

Efeito da aplicação de fosfopeptidio de caseina-fosfato de calcio amorfo (CPP-ACP) associada ao protocolo adesivo na resistencia de união de um selante de fossulas e fissuras / Effect of the casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) associated to adhesive procedures on bond strength of a pit and fissure sealant

Borges, Boniek Castillo Dutra 15 August 2018 (has links)
Orientador: Flavio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T16:07:16Z (GMT). No. of bitstreams: 1 Borges_BoniekCastilloDutra_M.pdf: 1684479 bytes, checksum: c40bc0507b501c53b9ecebcc18575278 (MD5) Previous issue date: 2010 / Resumo: O objetivo deste trabalho foi investigar, in vitro, o efeito da aplicação de uma pasta contendo fosfopeptídeo de caseína - fosfato de cálcio amorfo (CPP-ACP) (MI Paste - MI) previamente ao protocolo adesivo na resistência da união de um selante resinoso de fóssulas e fissuras ao esmalte dental humano. Foram utilizados 98 espécimes de esmalte proximal de terceiros molares totalmente erupcionados, divididos em 14 grupos experimentais (n=7): G1/G8- condicionamento ácido (CA) (Scotchbond Etchant), sem a aplicação de sistema adesivo; G2/G9- CA + resina hidrófoba de um sistema adesivo convencional de três passos (Scotchbond Multipurpose Plus); G3/G10- CA + sistema adesivo convencional de dois passos (Single Bond 2); G4/G11 - CA + sistema adesivo autocondicionante de passo único (Clearfil S3 Bond); G5/G12- CA + sistema adesivo autocondicionante de dois passos (Clearfil SE Bond); G6/G13- sistema adesivo autocondicionante de dois passos; G7/G14- adesivo autocondicionante de passo único. MI foi aplicada previamente ao protocolo adesivo apenas nos grupos de G1 a G7. Após selamento das superfícies (FluroShield), foram confeccionados blocos retangulares (palitos) (~0,7mm2 de área seccional) para o ensaio de microtração. O teste foi efetuado imediatamente após confecção das amostras por meio da Máquina de Ensaio Universal, na velocidade de 0,5 mm/min. Após, o padrão de fratura foi analisado por meio de Microscopia Eletrônica de Varredura (MEV). Os valores de resistência da união foram analisados por meio de ANOVA dois fatores com parcela subdividida. A aplicação da pasta contendo CPP-ACP previamente aos sistemas adesivos convencionais e àqueles autocondicionantes sem condicionamento ácido prévio aumentou os valores de resistência da união. Houve predomínio de fraturas mistas nos grupos que receberam MI Paste, ao passo que, naqueles em que não se aplicou MI Paste a maior prevalência foi de fraturas adesivas. O contato do esmalte com CPP-ACP anteriormente à aplicação dos sistemas adesivos é um método eficaz para aumentar a resistência de união entre esmalte e selantes de fóssulas e fissuras. / Abstract: This study evaluated the effect of applying a casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) containing paste (MI Paste - MI) previously to adhesive procedures on the microtensile bond strength of a pit and fissure sealant to human enamel in vitro. Ninety eight fragments were obtained from proximal surfaces of totally erupted third molars. Specimens were divided into 14 experimental groups (n=7): G1/G8- phosphoric acid conditioning (PA) (Scotchbond Etchant) and no adhesive system; G2/G9- PA + hydrophobic resin of a three step adhesive system (Scotchbond Multipurpose Plus); G3/G10- PA + etch-and-rinse two-step adhesive system (Single Bond2); G4/G11- PA + all-in-one adhesive (Clearfil S3-Bond); G5/G12- PA + two-step self-etching adhesive system (Clearfil SE-Bond); G6/G13- all-in-one adhesive; G7/G14- two-step self-etching adhesive system. MI was applied on the enamel before adhesive strategies only for groups from G1 to G7. After sealing (FluroShield), beams with approximately 0.7 mm2 of sectional area were cut for microtensile test, which was executed trough a universal test machine at a speed of 0.5 mm/min. Fractured specimens were analyzed by scanning electronic microscopy to determine failure modes. Bond strength data was statistically analyzed by two-way ANOVA with subparcels. Groups which MI was applied on the enamel followed by sealant bonding with etching-and-rinse and self-etching adhesives without additional enamel acid etching presented higher means than other which MI was not applied. Higher frequency of cohesive failures was observed for groups with MI, while adhesive fractures were more prevalent in groups without MI. Applying a CPP-ACP containing paste before adhesive systems to the enamel is an effective method to increase bond strength of the sealant tested. / Mestrado / Dentística / Mestre em Clínica Odontológica
366

Influência do selamento imediato da dentina na resistência de união de diferentes sistemas adesivos junto a cimentações de restaurações indiretas / Influence of immediate dentin sealing on bond strength of different adhesive systems on the cementation of indirect restorations

Rafael Barroso Pazinatto 30 September 2010 (has links)
Hipótese do estudo: A presente pesquisa hipotetiza que a técnica de cimentação está diretamente ligada a resistência adesiva de restaurações indiretas. Objetivos: O presente estudo experimental verificou se o selamento imediato da dentina, com diferentes sistemas adesivos, apresentaram melhores resultados de resistência de união junto a cimentação resinosa de restaurações indiretas. Métodos: Foram utilizados 48 terceiros molares humanos, divididos em seis grupos de acordo com as técnicas de cimentação testadas: grupo 1) Sistema Variolink II (Ivoclar Vivadent); grupo 2) Clearfill SE (Kuraray) + Variolink II; grupo 3) Selamento com Clearfill SE + Sistema Variolink II após 24h; grupo 4) Selamento com Exite DSC (Ivoclar Vivadent) + Sistema Variolink II; grupo 5) Selamento com Clearfill + Tetric Evo Flow (Ivoclar Vivadent) + Sistema Variolink II após 24h; Grupo 6) selamento com Exite DSC + Tetric Evo Flow + Sistema Variolink II após 24h. Oito amostras de cada grupo foram para máquina de cortes seriados (Isomet 1000) para obtenção de palitos com 1mm2 de área. Os palitos de cada grupo foram submetidos ao teste de microtração. O teste de microtração foi utilizado após 24h da cimentação. Os dados foram estatisticamente analisados pelo teste de Kruskal-Wallis e o teste de Dunn (5%). Diferenças significativas foram detectadas (p=0,0074). Resultados: Os grupos 1 e 2 apresentaram mediana de resistência de união intermediária, sendo estatisticamente semelhantes aos demais grupos. O grupo 6 apresentou mediana significativamente mais alta que os grupos 3, 4 e 5, os quais foram semelhantes entre si. Adicionalmente os tipos de fratura foram analisados com auxílio de lupa estereoscópica, em todos os grupos a porcentagem de fraturascoresivas em dentina ou mistas foi menor em comparação as fraturas adesivas e coesivas em cerômeros. Conclusão: O selamento imediato da dentina com adesivo de condicionamento total junto a resina flow demonstrou maior resistência adesiva. / Hypothesis of the study: This study hypothesizes that the cementation technique is directly related to the bond strength of indirect restorations. Objectives: The present experimental study examined whether the immediate dentin sealing with different bonding systems, the best-performing bond strength in the resin cementation of indirect restorations. Methods: A total of 48 human third molars was divided into six groups according to the techniques of tested: group 1) Variolink System II (Ivoclar Vivadent), group 2) Clearfill SE (Kuraray) + Variolink II, Group 3) with Seal Clearfill SE + System Variolink II after 24h, group 4) Sealing successfully DSC (Ivoclar Vivadent) + Variolink System II, Group 5) Sealing with Clearfill + Tetric Evo Flow (Ivoclar Vivadent) + System Variolink II after 24h, Group 6) sealing successfully DSC + + Tetric Evo Flow System Variolink II after 24h. Eight samples of each group were machine serial sections (Isomet 1000) to obtain sticks with 1 mm2 in size. The sticks of each group were subjected to microtensile testing. The microtensile test was performed used after 24h of cementation. The data were statistically analyzed by Kruskal- Wallis test and Dunn (5%). Significant differences were detected (p = 0.0074). Results: Groups 1 and 2 had a median of intermediate bond strength, being statistically similar to other groups. The sixth group median significantly higher than groups 3, 4 and 5, which were similar. Besides the types of fracture were analyzed with the aid of a stereomicroscope. Conclusions: The immediate detin sealing with total etch adhesive and the flowable resin showed higher bond strength.
367

Influência de três sistemas adesivos na resistência à extrusão de pinos de fibras de vidro fixados com um cimento resinoso / Influence of three adhesives systems on the extrusion strength of glass fiber posts fixed by resin cements

Juliana Cefaly Raineri 03 May 2006 (has links)
Com o intuito de elevar os valores de resistência à fratura dos dentes que sofreram tratamento endodôntico, várias técnicas restauradoras têm sido desenvolvidas. Atualmente os sistemas de pinos de fibras de carbono e de vidro são os dispositivos mais utilizados, devido às suas vantagens de possuírem módulo de elasticidade próximo ao da dentina, o que causa menor estresse e conseqüentemente menor quantidade de fraturas radiculares, além de não necessitarem da fase laboratorial. A escolha do cimento utilizado para a cimentação desses pinos, tem grande importância e o advento dos cimentos resinosos e dos sistemas adesivos que com eles podem ser empregados, representam uma grande evolução em razão das possibilidades de se obter retenções micromecânicas no interior dos condutos. Assim, o objetivo deste estudo foi avaliar a resistência à extrusão de pinos de fibras de vidro cimentados com cimento resinoso Rely X ARC com a aplicação de três diferentes sistemas adesivos: Scotchbond, Single bond e Adper Prompt LPop. Após a cimentação os espécimes foram seccionados em duas regiões, apical e cervical, que constituía cada uma um corpo de prova. Para possibilitar a realização do teste de extrusão, utilizou-se um dispositivo de aço inoxidável que estabilizava o corpo de prova. Este dispositivo tinha um orifício central que permitia o deslocamento do pino ou do cimento, durante o teste de extrusão. Para o teste de extrusão o corpo de prova foi adaptado no dispositivo com a face cervical voltada para baixo e uma ponta ativa com extremidade plana (1mm de diâmetro) foi adaptada à máquina de ensaios universal que exercia uma força de extrusão o mais próximo possível do centro do pino. O teste foi realizado com um deslocamento de 0,5mm por minuto, onde a carga máxima de falha foi registrada em kgf. No que diz respeito ao cimento resinoso Rely X ARC, em combinação com os adesivos utilizados, os melhores resultados na região cervical da raiz foram obtidos com o cimento Rely X com o sistema adesivo Scotchbond, seguido pelos sistemas Adper Prompt e Single bond. Na região apical o Scotchbond foi melhor que o Adper Prompt e o Single bond, mas não houve diferença estatisticamente significante entre o Adper Prompt e Single bond. / In order to increase strength to fracture of endodontically treated teeth, a number of restorative techniques were developed. Nowadays, carbon and glass fiber post systems are the most used due to their advantages of modulus of lasticity similar to dentin, which lead to lower stress and consequently lower number of root fractures, besides no laboratorial work is needed. The choice of the best cement for luting these posts is an important step and the development of resin cements and adhesive systems that can be use with posts are a great evolution due to the possibility of micromechanical retention in roots. Therefore, the aim of this study was to evaluate extrusion strength of glass fiber posts cemented with resin luting cement Rely X ARC using three different adhesive systems: Scothbond, Single bond and Adper Prompt L Pop. After luting, samples were seccionated in two regions, apical and cervical, each one representing one sample. A stainless steel device was used to perform extrusion test, stabilizing samples. This device had a central orifice that allowed movement of post or cement, during extrusion test. For extrusion test, sample was adapted in the device with cervical face directed to down and a plane surface active point (1 mm diameter) was adapted to the universal test machine which exerted an extrusion force in the center of post. Test was performed with 0.05 mm per minute and the maximum load at failure was registered in kgf. Regarding resin luting cement Rely X ARC combining with adhesive systems, the best results at cervical were obtained with Rely X and Scotchbond adhesive, followed by Adper Prompt and Single bond systems. At apical region Scotchbond was better than Adper Prompt and Single bond, but there was no statistically significant difference between Adper Prompt and Single bond.
368

Adesão à superfície de esmalte clareado: avaliação in vitro por microtração / Adhesion to the bleached enamel surface: in vitro assessment through microtensile

Andréa Dias Neves Lago 03 June 2009 (has links)
O clareamento e os procedimentos adesivos são soluções muito utilizadas na Odontologia atual. Assim, o objetivo deste trabalho foi avaliar, in vitro, a resistência adesiva ao esmalte clareado através do ensaio mecânico de microtração. Dois sistemas adesivos autocondicionantes (Clearfil SE Bond - Kuraray e Adper Prompt LPop - 3M Espe) e um adesivo convencional (Adper Single Bond 2 - 3M Espe) foram aplicados imediatamente, 7 e 14 dias após o clareamento com peróxido de hidrogênio a 35% (Whiteness HP - FGM) ao esmalte. Foram utilizados 60 dentes bovinos que tiveram a superfície de esmalte planificada e em seguida divididos em 12 grupos (9 experimentais e 3 controles) de acordo com o adesivo empregado e o intervalo entre o clareamento e os procedimentos adesivos. O ensaio de microtração foi realizado 24 h após a confecção das restaurações e a área de fratura foi avaliada através da microscopia eletrônica de varredura. Houve redução significativa da resistência adesiva nos dentes restaurados imediatamente após o clareamento com todos os adesivos utilizados. Após 7 e 14 dias do término do clareamento, os valores de resistência adesiva se igualaram e foram semelhantes aos valores dos grupos controles dos respectivos sistemas adesivos empregados. O adesivo Adper Single Bond 2 apresentou os maiores valores de resistência adesiva e o Adper Prompt L Pop os mais baixos. Houve predominância de fraturas adesivas e mistas em todos os grupos. / Bleaching and adhesive proceedings are solutions much used in current Dentistry. Thus, this work aimed at assessing, in vitro, the adhesive resistance to bleached enamel through the microtensile mechanical trial. Two self-etch adhesive systems (Clearfil SE Bond - Kuraray and Adper Prompt L-Pop - 3M Espe) and a conventional adhesive (Adper Single Bond 2 - 3M Espe) were immediately employed, 7 and 14 days after bleaching with hydrogen peroxide at 35% (Whiteness HP - FGM) in the enamel. 60 bovine teeth were used, which had the enamel surface planned and following randomly divided into 12 groups (9 experimental and 3 controls) according to the employed adhesive and to the interval between the bleaching ending and the adhesive proceedings. The microtensile trial was accomplished 24 hours after the confection of the tooth fillings and the fracture area was assessed through scanning electronic microscopy. There was significant reduction of the adhesive resistance in the filled teeth immediately after bleaching with all employed adhesives. After 7 and 14 days of the bleaching ending, the adhesive resistance values were equated and were similar to the values of the control groups and to the respective adhesive systems employed. The Adper Single Bond 2 adhesive presented the highest adhesive resistance values and the Adper Prompt L-Pop presented the lowest ones. There was predominance of adhesive and mixed factures in all groups.
369

Influência da adição de nanopartículas de prata no efeito antibacteriano, na alteração de cor, na sorção e solubilidade de adesivos dentários / Influence of silver nanoparticles on the anbacterial effect, color change, sorption and solubility of dental adhesives

Moreira, Francine do Couto Lima 26 September 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:39:30Z No. of bitstreams: 1 Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-16T09:53:06Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-29T18:57:50Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-29T18:58:08Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Made available in DSpace on 2014-12-29T18:58:08Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) Previous issue date: 2013-09-26 / Aim: to evaluate the influence of silver nanoparticles to antibacterial effect, color change, sorption, and solubility of dental adhesives. Material and methods: they were analised four groups of dental adhesives: SB - AdperTM Single Bond 2 without adding NAg, SM - AdperTM Scotchbond Multi-use without adding NAg; SBAg - SB with addition of 0.1% of NAg ; SMAG - SM with addition of 0.1% of NAg. One handred and thirty two specimens of the adhesives were prepared according to the standard of ISO 4049:2010, with circular geometry dimensions of 10mmx1mm. After different periods of specimens contamination with Streptococcus mutans (ATCC 25175) (1min; 5min; 1h; 6h, e 24h) the antimicrobial activity was observed by bacterial grouth (optical density), and the presence/absence of bacteria on the specimens surface by Scanning Electron Microscopy (2500x e 5000x). Also evaluated the color change of specimens after adding NAg through the CIELab system, and sorption and solubility tests (ISO 4049:2010) were performed to verify the polymeric quality of materials. Data were subjected to analysis of variance (ANOVA) followed by Tukey test for multiple comparisons, with p=0.05 for all tests, except for analysis of ΔE what underwent Pearson`s correlation (p=0.01). Results: there were no statistical differences between the values of optical density of the culture broth used to store the specimens contaminated with S. mutans, even with the addition of NAg (p>0.05). Both adhesives have significant change in color, after the addition of nanosilver in its composition (p<0.01). No statistical differences were observed on the values of sorption and solubility differences as the addition of NAg in studied adhesives (p>0.05). Conclusion: addition of 0.1% pure silver nanopowder in dental adhesive did not confer antibacterial effect to the material, cause material color changes and did not affect the values of sorption and solubility. / Objetivo: avaliar a influência da adição de nanopartículas de prata (NAg) no efeito antibacteriano, na alteração de cor, na sorção e solubilidade de adesivos dentários. Material e métodos: para tanto foram analisados quatro grupos de adesivos dentários: SB - AdperTM Single Bond 2 sem adição de NAg; SM - AdperTM Scotchbond Multi-uso sem adição de NAg; SBAg – SB com adição de 0,1% de NAg; SMAg - SM com adição de 0,1% de NAg. Cento e trinta e dois espécimes dos adesivos foram confeccionados segundo a norma da ISO 4049:2010, com geometria interna circular nas dimensões de 10mmX1mm. Após diferentes períodos de contaminação dos espécimes com Streptococcus mutans (ATCC 25175) (1min; 5min; 1h; 6h e 24h), o efeito antibacteriano foi analisado por meio de densidade óptica e a presença/ausência de bactérias na superfície dos espécimes por microscopia eletrônica de varredura (2500x e 5000x). Avaliou-se também a alteração de cor (ΔE) dos espécimes após a adição da NAg, utilizando espectrofotômetro com base no sistema CIELab. Os testes de sorção e solubilidade (ISO 4049:2010) foram realizados para verificar a qualidade polimérica dos materiais. Os dados obtidos foram submetidos a uma análise de variância (ANOVA), seguida pelo teste de Tukey, para comparações múltiplas, com p=0,05, para todos os testes, exceto para análise do ΔE que foi submetido à correlação de Pearson (p=0,01). Resultados: não foram observadas diferenças estatísticas entre os valores de densidade óptica dos meios de cultura utilizados para armazenar os espécimes contaminados com S. mutans, mesmo com a adição de NAg (p>0,05). Ambos os adesivos sofreram alteração de cor significante, posterior à adição da nanoprata em sua composição (p<0,01). Quanto aos valores de sorção e solubilidade não foram observadas diferenças estáticas quanto à adição de NAg nos adesivos estudados (p>0,05). Conclusão: a adição de nanopartículas de prata, pura, em pó a 0,1%, nos adesivos dentários não conferiu efeito antibacteriano ao material, causou alteração de cor e não interferiu nos valores de sorção e solubilidade dos mesmos.
370

Avaliação da influência de agentes químicos previamente à aplicação de sistemas adesivos autocondicionantes na resistência adesiva à dentina / Evaluation of the influence of chemical agents before applying Self-etching Adhesives on dentin Bond Strength

Thiago Majolo Valeretto 27 April 2012 (has links)
Com os sistemas adesivos autocondicionantes, o uso prévio do ácido fosfórico passou a ser dispensado em dentina. Assim, outras soluções foram propostas a fim de se promover uma limpeza da cavidade e otimizar um melhor embricamento do adesivo ao substrato. O objetivo deste estudo foi avaliar a influência de soluções químicas à adesão à dentina bovina, por meio da resistência ao microcisalhamento, de três sistemas adesivos autocondicionantes em função do tempo. Duzentos e quarenta incisivos bovinos foram incluídos, desgastados e polidos em série com lixas de carbeto de silício, obtendo uma superfície planificada de dentina de 10 mm de diâmetro. Os espécimes foram divididos aleatoriamente em 4 grupos, de acordo com a solução aplicada: SF- aplicação de soro fisiológico com 0,9% NaCl (grupo controle); HS- desproteinização com hipoclorito de sódio a 5%, por 2 minuto e HSAA- hipoclorito de sódio a 5%, por 2 minuto seguida da aplicação de ácido ascórbico (ascorbato) a 10%, por 1 minuto; CHX- aplicação de solução clorexidina a (2% por 1 minuto). Às superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes, por grupo - Optibond All-in-One (KERR), Filtek P90-System Adhesive (3M-ESPE) e Adper SE (3M-ESPE), todas seguidas da inserção de resina composta (Filtek Z250 ou Filtek P90). Metade dos espécimes de cada grupo foram armazenados por 24 horas e metade por 6 meses. Após esses períodos, os espécimes foram submetidos ao teste de microcisalhamento, em uma máquina de ensaios universal (Emic, na velocidade de 0,5mm/min). Os dados foram avaliados estatisticamente através de análise de variância (ANOVA) a três critérios e testes de comparações múltiplas de Tukey ambos considerando a=0,05. O adesivo Filtek P90-System Adhesive foi o único que manteve a resistência adesiva após o envelhecimento, porém, os dois tratamentos de superfície contendo hipoclorito de sódio influenciaram negativamente. Já com a clorexidina não houve diferença estatisticamente significante comparada ao grupo controle. O adesivo OptiBond All- In-One (Kerr) foi influenciado positivamente pelo hipoclorito de sódio e hipoclorito de sódio mais ascorbato, no tempo de 24 horas. Sendo de iqual resultado com o envelhecimento em solução aquosa. Adper SE (3M-ESPE) sofreu influência dos tratamentos à base de hipoclorito de sódio. O melhor resultado, comparando dois tratamentos com hipoclorito, após o envelhecimento, foi obtido pelo tratamento com o hipoclorito de sódio mais ascorbato sendo estatisticamente idêntico ao grupo controle. Foi concluído que os tratamentos de superficie influenciam na resistência adesiva dos adesivos testados. A clorexidina possibilitou os melhores resultados em quase todos os testes. / With the Self-etching adhesives, acid-etching with phosphoric acid has to be dispensed in dentin. Than, other solutions have been proposed in order to promote the cavity cleaner and improvement in bonding effectiveness. The aim of this study was to investigate the microshear bond strength, with the influence of chemical solutions and time, in three adhesive systems used on bovine dentin. Two hundred and forty bovine incisors were included, and the surface was polished in series with silicon carbide paper, getting flattened dentin surface of 10 mm in diameter. The specimens were randomly divided into four groups, according to the applied solution: SF- saline solution with 0.9% NaCl (control group), HS-deproteinization with sodium hypochlorite at 5%, for 2 minutes and HSAA- sodium hypochlorite 5% for 2 minutes followed by the application of ascorbic acid (ascorbate) and 10% for 1 minute;CHXapplication of chlorhexidine solution (2% for 1 minute). Were applied to surfaces prepared three adhesive systems, per group - Optibond All-in-One (Kerr), Filtek-P90 System Adhesive (3M-ESPE) and Adper SE (3M-ESPE), all followed by the insertion of composite resin ( Filtek Z250 and Filtek P90). Half of the specimens of each group / treatment were stored for 24 hours and half for six months. After these periods were tested using the microshear in a universal testing machine (Emic, the speed of 0.5 mm / min). Results were submitted to three way ANOVA and TUKEY test multiple comparison both considering a = 0.05. The adhesive Filtek P90 System Adhesive was the one who kept the bond strength after aging, however, the two surface treatments containing sodium hypochlorite influenced negatively. With chlorhexidine, there was no statistically significant difference compared to the control group. The adhesive OptiBond All-in-One (Kerr) was affected by the sodium hypochlorite, sodium hypochlorite more ascorbate, at 24 hours. As a result of iqual with aging in aqueous solution. Adper SE (3M-ESPE) was influenced by the treatments using sodium hypochlorite. The best result, comparing two treatments with hypochlorite, after aging, was obtained by treatment with sodium hypochlorite more ascorbate was statistically identical to the control group. It was concluded that the influence of surface treatments on bond strength of adhesives tested. The chlorhexidine resulted in better results in almost every test.

Page generated in 0.0338 seconds