• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 319
  • 88
  • 77
  • 29
  • 14
  • 14
  • 5
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 691
  • 94
  • 79
  • 64
  • 56
  • 54
  • 52
  • 46
  • 45
  • 44
  • 44
  • 44
  • 39
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
591

Avaliação citogenética molecular de células do líquido pleural de pacientes com derrame pleural maligno / Molecular cytogenetic evaluation of pleural fluid cells in patients with malignant pleural effusion

Debora Cristina Batista Rosolem 29 September 2014 (has links)
Introdução O diagnóstico de derrame pleural maligno (DPM) se baseia no achado de células tumorais no líquido ou no tecido pleural. Resultados falsos positivos ou falsos negativos influenciam na escolha da melhor conduta terapêutica a ser tomada, além de alterar substancialmente o prognóstico desses pacientes. A sensibilidade do exame citológico é geralmente inferior a 70%, motivo pelo qual, métodos complementares são frequentemente associados. Fatores como tipo histológico, sítio primário e grau de invasibilidade do tumor são os principais responsáveis por esta variação. Dentre os exames complementares propostos, destacam-se a dosagem de marcadores tumorais no líquido pleural (LP), as técnicas citoquímicas, imunocitoquímicas e de marcadores de proliferação celular em células do LP, a análise da ploidia de DNA por citometria de fluxo (CF) ou estática (CE) e, mais recentemente, as técnicas de citogenética e de biologia molecular, como a técnica de hibridação in situ por fluorescência (FISH) e a técnica de amplificação multiplex por sondas ligação - dependentes (MLPA) estas, capazes de detectar alterações em regiões gênicas consideradas \"alvo\" para o desfecho neoplásico. Objetivos 1) Padronizar as técnicas de DNA ploidia, FISH e MLPA em amostras frescas de líquido pleural; 2) Testar a eficiência diagnóstica dos métodos da DNA ploidia e da FISH no diagnóstico de derrame pleural maligno e 3) Avaliar alterações no número de cópias no gene EGFR em metástases pleurais utilizando a técnica de MLPA. Métodos Foram incluídos 200 pacientes adultos portadores de derrame pleural (DP) com indicação de toracocentese. O diagnóstico histológico foi o padrão ouro para malignidade. Características clínicas, radiológicas, histológicas e de seguimento clínico foram considerados para a exclusão de malignidade, de maneira que 130 casos foram classificados como malignos e 70 como benignos. As 200 amostras de LP foram submetidas ao exame citológico e à FISH utilizando sondas centroméricas para os cromossomos 11 e 17. A análise da ploidia de DNA por CF foi realizada em 45 casos de DP e a MLPA com o kit do gene do receptor do fator de crescimento epidérmico (EGFR) em 50 casos. Resultados A análise da ploidia de DNA por CF apresentou sensibilidade inferior ao exame citológico, com especificidade próxima (57,0%vs 96,2%; 70,0% vs 66,7%, respectivamente). A FISH isoladamente apresentou sensibilidade de 98,5% e especificidade de 98,6% e de 98,0% e 99,% quando associada ao exame citológico, com apenas um caso falso positivo e dois casos falsos negativos. A técnica de MLPA, padronizada para LP, demonstrou alterações na sequência do gene do EGFR em 28,2% dos casos malignos. Nenhuma amostra de líquido pleural dos casos benignos (controle) apresentou alteração no número de cópias e/ou rearranjos estruturais. Conclusão A análise citogenética de amostras frescas de líquido pleural por FISH é um valioso complemento ao exame citológico no diagnóstico de derrame pleural maligno, particularmente nos casos em que o resultado da citologia oncótica é inconclusiva / Introduction The diagnosis of malignant pleural effusion (MPE) is based on the finding of tumor cells in the pleural fluid or tissue. False positive or false negative results influence the choice of the best therapeutic approach to be used with these patients and substantially change their prognosis. The sensitivity of the cytology is generally lesser than 70%, for which complementary methods are often associated. Factors such as tumor histological type, staging, primary site and potential of invasiveness are responsible for this variation. Among the proposed ancillary tests, we highlight the dosage of tumor markers in pleural fluid (PF), the cytochemical and immunocytochemical techniques, including markers of cell proliferation, DNA ploidy analysis by flow cytometry (FC) or static cytometry (EC) and more recently, the cytogenetics and molecular techniques, as the fluorescence in situ hybridization (FISH) and the multiplex ligation - dependent probe amplification (MLPA), capable of detecting changes in gene regions considered \"target\" for the neoplastic outcome. Objectives 1) To standardize the techniques of DNA ploidy, FISH and MLPA in fresh samples of pleural fluid; 2) To test the diagnosis efficiency of DNA ploidy and FISH in the diagnosis of malignant pleural effusion and 3) To evaluate changes in the copy number of the EGFR gene by using the MLPA technique in cases of pleural metastases. Methods We included 200 adult patients with pleural effusion and clinical indication for thoracentesis. The histological diagnosis was considered the gold standard for malignancy. Clinical follow-up, radiological and histological characteristics were considered for exclusion of malignancy, which ranked de cases as 130 malignant effusions and 70 as benign ones. All cases were submitted to cytology and FISH using centromeric probes for the chromosomes 11 and 17. Analysis of DNA ploidy by FC was performed in 45 cases and the MLPA for epidermal growth factor receptor (EGFR) gene in 50 cases. Results DNA ploidy analysis showed less sensitivity than PF cytology, with similar specificity (57.0% vs 96.2% and 70.0% vs 66.7%, respectively). FISH alone had a sensitivity of 98.5% and specificity of 98.6%, and of 98.0% and 99% when associated with cytology. Only one false positive and two false negative cases were observed. The MLPA technique, standardized for PF, showed changes in the EGFR gene in 28.2% of the malignant cases. No samples of pleural fluid from benign cases (control) showed changes in copy number and/or structural rearrangements. Conclusion The cytogenetic analysis of fresh pleural fluid samples by FISH seems to be a valuable method to be associated to cytology in the diagnosis of malignant pleural effusion, particularly in cases of inconclusive cytological results
592

Efeitos de gradientes perpendiculares na amplificação da radiação quilométrica das auroras

Pavan, Joel January 2007 (has links)
A in uência do caráter inomogêneo da região-fonte na ampli cação da Radiação Quilom étrica das Auroras é investigada. Inicialmente é feita uma revisão de trabalhos relevantes publicados a respeito do mesmo tema geral, tanto os que concernem aos dados observacionais como os que concernem aos modelos teóricos e simulações numéricas. Esta revisão é precedida pelo estabelecimento de conceitos e de nições pertinentes ao tema. São consideradas duas abordagens distintas na determinação da ampli cação da radiação na região-fonte. A primeira considera o plasma localmente homogêneo, enquanto a segunda toma em conta, explicitamente, a contribuição dos gradientes dos parâmetros do plasma. A ampli cação da radiação é determinada pela avaliação do tensor dielétrico do plasma e pela evolução da radia ção através do estudo de traçado de raios. Os parâmetros do plasma são obtidos através de uma formulação autoconsistente que toma em conta uma queda de potencial elétrico ao longo das linhas de campo geomagnético. Utiliza-se um modelo de lâmina auroral em que o campo magnético ambiente é considerado localmente homogêneo. O modelo teórico subjacente adotado é o do maser de elétron-cíclotron. O principal resultado obtido revela uma diminuição na ampli cação nal por um fator em torno de três, quando os gradientes dos parâmetros do plasma são considerados explicitamente. Este resultado pode ter implicações na capacidade do maser de elétron-cíclotron em explicar os níveis de radiação mais elevados observados. / The in uence from source region inhomogeneous character on ampli cation of Auroral Kilometric Radiation is investigated. Firstly, a review over relevant works published about the same general theme is made, concerning about observational data as well theoretical models and numerical simulations. This review is preceded by the establishment of de nitions and concepts related to the theme. Two distinct approaches are considered in determining the ampli cation of radiation across the source region. First approach takes the plasma as locally homogeneous, while second approach account, explicitly, for gradients on plasma parameters. The ampli cation is obtained through evaluation of the dielectric tensor and the evolution of radiation through ray tracing. Plasma parameters are obtained using a self-consistent formulation which account for an electric potential drop along geomagnetic eld lines. An auroral slab model is used where the ambient magnetic eld is taken as locally homogeneous. The subjacent theoretical model adopted is the electron-cyclotron maser. The main result obtained reveals a reduction on nal ampli cation by a factor about three, when plasma parameters gradients are explicitly accounted. This nding may have implications on capability of electron-cyclotron maser for explanation the most intense levels of radiation observed.
593

Análise do número de cópias dos genes IGFIR, SF1 e FGFR4 em tumores adrenocorticais de crianças e adultos / Analysis of copy number variations of IGF1R, SF1 and FGFR4 genes in adrenocortical tumors from children and adults

Ribeiro, Tamaya Castro 30 August 2010 (has links)
Introdução: Uma elevada incidência de tumores adrenocorticais pediátricos e de adultos é observada nas regiões sul e sudeste do Brasil. Hiperexpressão dos genes IGF1R, SF1 e FGFR4 tem sido descrita em tumores adrenocorticais. Apesar de hiperexpressão ser um evento comum em diversas neoplasias, ainda não são claros os mecanismos moleculares que seriam responsáveis por essa falha na regulação da expressão. Objetivos: Determinar o número de cópias dos genes IGF1R, SF1 e FGFR4 em tumores adrenocorticais diagnosticados em crianças e adultos. Adicionalmente correlacionaremos os dados de expressão gênica e/ou protéica de IGF1R, SF1 e FGFR4 com o diagnóstico histológico e evolutivo dos tumores adrenocorticais. Pacientes e métodos: Sessenta e quatro pacientes com tumores adrenocorticais foram selecionados para o estudo. Todos os pacientes foram submetidos à avaliação clínica e tratamento cirúrgico. Oito glândulas adrenais normais obtidas em cirurgias renais ou autópsias foram utilizadas como controles. DNA genômico extraído dos tecidos normais e tumorais da glândula suprarrenal foram utilizados como substrato nas reações de multiplex ligation-dependent probe amplification (MLPA) com o intuito de se determinar o número de cópias dos genes IGF1R, SF1 e FGFR4. PCR em tempo real (SYBR Green) foi realizado para confirmar os dados de MLPA para os genes IGF1R e SF1. Resultados: Amplificação do gene IGF1R foi detectada por MLPA e confirmada por PCR em tempo real SYBR Green em apenas um carcinoma adrenocortical. Adicionalmente, amplificação gênica de outros loci (IGFBP3, FGFR4 e NSD1) bem como de sondas controles foi observada, sugerindo uma condição aneuplóide neste tumor maligno. Amplificação de SF1 foi detectada em 10 tumores adrenocorticais (8 pediátricos e 2 de adultos). Os valores de expressão gênica foram significantemente maiores em tumores associados com amplificação gênica quando comparados com tumores sem amplificação. Além disso, imunorreatividade para SF-1 foi detectada nos tumores com aumento no número de cópias. Doze amplificações do locus FGFR4 (3 pediátricos e 9 de adultos) foram demonstradas por MLPA. A amplificação do locus FGFR4 e hiperexpressão deste gene foram significantemente mais relacionados a carcinomas. Conclusões: Amplificação do gene IGF1R é um evento raro nos tumores adrenocorticais pediátricos e de adultos. A hiperexpressão de IGF1R em tumores adrenocorticais pediátricos não foi secundária à amplificação gênica. Amplificação do gene SF1 foi evidenciada predominantemente em tumores adrenocorticais pediátricos e se correlacionou com hiperexpressão gênica e protéica. Amplificação do locus FGFR4 foi demonstrada predominantemente em tumores adrenocorticais malignos de adultos. Amplificação de oncogenes representa um mecanismo molecular relevante na tumorigênese adrenocortical / Introduction: A high incidence of adrenocortical tumors in children and adults has been observed in Southern and Southeastern regions of Brazil. Overexpression of IGF1R, SF1 and FGFR4 genes have been described in adrenocortical tumors. Despite of overexpression be a common event in several neoplasias, the molecular mechanism implicated in this upregulation remains unknown. Objectives: To determine the copy number of IGF1R, SF1 and FGFR4 genes in pediatric and adult adrenocortical tumors. Additionally, correlate with IGF1R, SF1 and FGFR4 gene and/or protein expression data as well as with the histological diagnosis and evolution of the adrenocortical tumors. Patients and methods: Sixty and four patients with adrenocortical tumors were selected for this study. All patients were submitted to clinical evaluation and surgical treatment. Eight normal adrenal glands obtained in renal surgery or autopsies were used as controls. The MLPA reactions were performed with the DNA extracted from adrenal gland tissues in order to determine the copy number of IGF1R, SF1 and FGFR4 genes. SYBR Green real-time PCR was carried out to confirm MLPA data for IGF1R and SF1 genes. Results: IGF1R amplification was detected by MLPA and confirmed by SYBR green real-time PCR in only one adrenocortical carcinoma. Additionally, other loci amplification was detected (IGFBP3, FGFR4 and NSD1) as well as for control probes, suggesting aneuploidy in this malignant tumor. SF1 amplifications were shown in 10 adrenocortical tumors (8 from children and 2 from adults). The SF1 mRNA levels were significantly higher in adrenocortical tumors associated with increased SF1 gene copies when compared with adrenocortical tumors without gene amplification. Moreover, all adrenocortical tumors with SF1 gene amplification showed a strong SF1 staining. Twelve FGFR4 locus amplifications (3 from children and 9 from adults) were demonstrated by MLPA. FGFR4 locus amplification and overexpression of this gene were significantly more related to carcinomas. Conclusions: IGF1R amplification is a rare event in adrenocortical tumors and it was not responsible for the IGF1R overexpression of pediatric and adult adrenocortical tumors. SF1 gene amplification was detected predominantly in pediatric adrenocortical tumors and was associated with gene and protein overexpression. FGFR4 locus amplification was demonstrated mainly in adult maligant adrenocortical tumors. FGFR4 amplification and upregulation were more associated to adrenocortical carcinomas. Oncogenes amplification represents an important molecular mechanism in adrenocortical tumorigenesis
594

Elucidating the Role of Neighborhood Deprivation in Hypertensive Disorders of Pregnancy

Winter, Kelly M 22 June 2018 (has links)
This dissertation examined risk factors for hypertensive disorders of pregnancy (HDP) — specifically whether neighborhood socioeconomic deprivation exacerbates individual socioeconomic disadvantage (deprivation amplification) to increase the likelihood of developing HDP. To select the optimal areal unit at which to investigate HDP, geographic proxies for neighborhoods were explored. A thematic review qualitatively examined nontraditional neighborhood boundaries identified through internet sources. Data from 2008–2012 Miami-Dade County, Florida birth records (n=121,421) and the U.S. Census Bureau were used for the remaining analyses. Ordinary least squares (OLS) and geographically weighted regression (GWR) analysis empirically compared the proportion of HDP prevalence explained by six areal units: census block groups, census tracts, ZIP code tabulation areas (ZCTAs), and three types of natural neighborhood — census units clustered based on an eight-item Neighborhood Deprivation Index. Multilevel logistic regression examined relationships between HDP, neighborhood deprivation, and individual-level factors. Odds ratios (OR) and adjusted odds ratios (aOR) were calculated. The thematic review found 22 potential alternatives to census boundaries developed through techniques such as crowd-sourcing and qualitative research. In the sensitivity analysis, census tracts aggregated at the scale of ZCTAs performed twice as well as any other model (GWR2 = 0.27) and were used as the Aim 3 unit of analysis. In the multilevel logistic regression, HDP was associated with moderate (aOR=1.13; CI: 1.05, 1.21) and high neighborhood deprivation (aOR=1.16; CI: 1.07, 1.26). Compared with mothers with private insurance, uninsured women (aOR=1.69; CI: 1.56, 1.84) and Medicaid recipients (aOR=1.12; CI: 1.05, 1.18) had higher HDP odds. Non-Hispanic Black women’s HDP odds were 1.58 times those of non-Hispanic White women. Cross-level interactions — between neighborhood deprivation and educational attainment and neighborhood deprivation and insurance status — did not reach statistical significance. Private sector neighborhood boundaries hold promise for developing new public health tools. Because they are relatively easy to generate from census data, natural neighborhoods may balance tradition and innovation. While no evidence of deprivation amplification was found, results suggested that individual-level and neighborhood deprivation are HDP risk factors. Interventions that target expectant mothers in deprived neighborhoods — particularly non-Hispanic Black and Hispanic women who lack health insurance — may help reduce HDP prevalence and disparities.
595

Le façonnage d'impulsions ultracourtes par amplification paramétrique optique à dérive de fréquence.

Nelet, Ambre 11 September 2007 (has links) (PDF)
Dans le cadre d'études menées autour du programme PETAL, nous avons développé de nouvelles architectures pour la pré-amplification d'impulsions par amplification paramétrique optique à dérive de fréquence (OPCPA). Dans ce travail, nous considérons l'OPCPA comme un moyen de contrôle et de mise en forme des impulsions. Nous suggérons trois architectures lasers qui aspirent chacune à répondre à des défauts de la technique OPCPA ou des chaînes dédiées à la FCI. Ainsi, nous pallions un possible défaut de recouvrement temporel entre les impulsions pompe et signal, lequel induit une mauvaise extraction d'énergie lors du processus paramétrique. Dans ce cadre, nous avons démontré qu'une cavité régénérative OPCPA, résonnante sur l'onde complémentaire, permet d'optimiser l'amplification. Au-delà ce système permet de produire un train de répliques amplifiées de l'onde signal. Notre second montage vise à pré-compenser le rétrécissement spectral par le gain en façonnant les impulsions signal au niveau de l'étage OPCPA dans les domaines spatial et spectral. Nous avons démontré que ceci pouvait être réalisé en mettant en forme temporellement et spatialement le faisceau pompe. Enfin, nous proposons un OPCPA basé sur l'adressage spatial et l'amplification uniforme des composantes spectrales dans un cristal à polarisation périodique de type éventail.
596

Innovation et optimisation d'une méthode de polarimétrie pompe-sonde avec des faisceaux laser impulsionnels en vue d'une mesure précise de violation de la parité dans l'atome de césium

Chauvat, Dominique 22 October 1997 (has links) (PDF)
Alors que toutes les expériences de violation de la parité (PV) dans les transitions atomiques très interdites utilisent jusqu'ici la détection par fluorescence, notre expérience est de type pompe-sonde avec détection du signal PV directement sur un faisceau sonde transmis. Un faisceau laser impulsionnel de polarisation linéaire ε_1 excite les atomes de césium sur la transition 6S-7S dans un champ électrique colinéaire E parallèle à k_ex. Le faisceau sonde (k_pr parallèle à k_ex) de polarisation linéaire ε_2 accordé sur la transition 7S-6P3/2 est amplifié. La petite asymétrie (de l'ordre de 10^-6) dans le gain qui dépend du sens du tnèdre (E, ε_1, ε_2) est la manifestation de l'effet PV. On la mesure par une apparente rotation de la polarisation sonde, impaire en E, dans un polarimètre utilisé en mode équilibré. La mise en oeuvre de nouveaux critères de sélection nous permet de discriminer le vrai signal PV de fausses rotations dues à des interférences électromagnétiques, aux effets géométriques, aux imperfections des polarisations pompe et sonde, ou à la présence de champs électriques ou magnétiques transverses. Ces critères de sélection exploitent la symétrie du signal PV - dichroisme linéaire - et la symétrie de révolution de l'expérience. Ceci permet non seulement de rejeter de faux signaux mais aussi d'identifier les mécanismes en jeu, la nature des défauts et de déterminer leur grandeur. Le rapport signal-sur-bruit actuel permet d'entreprendre des mesures PV à la précision statistique de 10%. Une mesure à 1% nécessite des améliorations. Nous avons démontré deux voies possibles. La première exploite l'amplification de l'asymétrie à fort gain, l'un des atouts majeurs de notre méthode de détection basée sur l'émission stimulée. La seconde combine l'augmentation de l'intensité sonde incidente et l'usage d'une lame dichroique amplifiant de petites rotations de polarisation.
597

Modélisation des processus liés à l'amplification et à la propagation d'impulsions étirées dans des chaînes laser de très haute intensité

Planchon, Thomas 20 November 2003 (has links) (PDF)
Cette thèse a pour sujet la modélisation et le contrôle des processus intervenant lors de l'amplification d'impulsions laser à dérive de fréquence.<br />Nous présentons les modèles utilisés, qui prennent en compte la propagation, les effets non linéaires et les effets thermiques se produisant dans les chaînes laser basées sur le principe de l'amplification à dérive de fréquence. Une validation expérimentale de ces modèles a permis de souligner l'importance des aspects spatiaux du laser pour modéliser finement le processus d'amplification.<br />Nous avons également étudié l'importance, durant la propagation, des aspects spatiaux avec des calculs de propagation après un miroir déformable et montré toutes les précautions nécessaires pour l'utilisation d'une boucle d'optique adaptative. Cette boucle d'optique adaptative est utilisée maintenant de manière journalière pour garantir la qualité de la tache focale du laser 100 TW du LOA.<br />Nous avons réalisé des études sur les effets spatio-temporels créés dans les systèmes de lentilles. Le retard local et l'élargissement de la durée globale, dus au temps de propagation (PTD) dans un système de lentilles, ont été mesurés. Cette mesure directe de l'élargissement global de la durée temporelle est la première à notre connaissance.<br />Enfin, le futur laser Pétawatt (LUIRE) du LOA a été dimensionné avec les modèles validés précédemment. Nous pouvons atteindre le régime Pétawatt (30 J, 30 fs) avec un amplificateur multipassage supplémentaire dont les caractéristiques sont présentées.
598

Étude expérimentale des fluctuations d'origine quantique en amplification paramétrique d'images

MOSSET, Alexis 05 November 2004 (has links) (PDF)
Ce mémoire présente une étude expérimentale des fluctuations spatiales d'origine quantique de l'intensité dans des images en amplification paramétrique optique (OPA). Dans un premier temps nous avons caractérisé la réponse d'une caméra CCD lors de la mesure du bruit de photons dans le plan transverse de l'image. Pour cela, nous avons montré la pleine aptitude des capteurs silicium pour le domaine visible (527 nm) et leur mauvaise réponse dans le proche IR (1055 nm). Puis nous avons calibré le capteur sur toute sa dynamique afin d'éliminer l'inhomogénéité de réponse des pixels et ainsi mesurer le bruit de photons dans des images faibles ou intenses. D'autre part, nous avons étudié les aspects quantiques des OPA. L'amplification à l'aide d'un cristal de BBO de type I d'images (527 nm) dominées par le bruit quantique à l'aide d'une pompe UV (264nm) s'est imposée comme le meilleur compromis expérimental. Nous avons mis au point un montage et un protocole de mesure permettant la comparaison entre l'amplification sensible à la phase (PSA) et l'amplification insensible à la phase (PIA). Dans le cas d'une PIA, nous avons mis en évidence la dégradation du rapport signal à bruit. Pour la configuration PSA, nous avons réalisé la première amplification paramétrique d'images sans bruit spatial. Pour ces deux cas, les valeurs expérimentales sont en accord avec la figure de bruit attendue. De plus, nous avons étudié la distribution des fluctuations spatiales de la fluorescence paramétrique. L'emploi d'impulsions brèves et un fort filtrage des longueurs d'onde ont permis la caractérisation directe de la distribution de Bose-Einstein pure.
599

Dynamique des Avalanches

Daerr, Adrian 23 November 2000 (has links) (PDF)
Un milieu granulaire peut rester au repos même avec une surface libre inclinée, et il ne se met spontanément en mouvement qu'au dessus d'un angle critique. Il apparaît alors un écoulement de surface dont l'amplitude et la dynamique sont régies par la mobilisation et le dépôt de grains à l'interface avec la phase statique. Malgré son importance pratique, la dynamique de cette transition demeure largement inconnue. Le manuscrit présente une étude expérimentale de ce problème dans deux géométries d'écoulements granulaires différentes. Dans la première expérience, l'équilibre d'une couche de sable déposée dynamiquement sur un plan rugueux est rendu métastable: après avoir augmenté l'inclinaison du plan, une perturbation locale déclenche une avalanche. La mesure du seuil de déclenchement montre que la transition entre équilibre statique et écoulement est sous-critique. La forme et la dynamique des avalanches résultent d'un échange permanent de matière avec la couche statique, mobilisant à l'avant et déposant des grains à l'arrière. De manière surprenante, une saturation de l'amplitude est observée, qui peut être attribuée à la présence du fond solide. Nous avons aussi mis en évidence l'existence de deux types d'avalanches, l'un où la couche n'est mobilisée qu'en aval du point de déclenchement et laissant une trace triangulaire, et l'autre où l'écoulement envahit tout le plan par un front de remontée. L'étude montre que des mécanismes de propagation différents interviennent dans ces deux cas. La deuxième expérience consiste à étudier l'écoulement transitoire à la formation d'un talus. Nous avons observé l'influence prépondérante de la préparation sur l'écoulement. Deux effets sont mis en évidence, l'un associé à la densité et l'autre à la «texture» anisotrope acquise pendant le remplissage. Dans la dernière partie, nous discutons de la validité des modèles existants pour décrire les avalanches sur le plan incliné. En guise de conclusion, nous développons un modèle continu décrivant la dynamique des écoulements granulaires de surface et prenant appui sur les résultats expérimentaux présentés.
600

Amplification optique dans des verres borophosphate de niobium et tellurite dopés aux ions de terres rares présentant un indice optique non linéaire élevé.

Petit, Laëticia 03 October 2002 (has links) (PDF)
Ce travail s'insère, non seulement, dans la compréhension de la relation entre la résonance des terres rares et l'indice non linéaire, mais aussi, dans la recherche de nouveaux matériaux dopés terres rares pour la commutation optique. L'introduction d'oxyde d'erbium dans des verres tellurites et borophosphates de niobium, présentant intrinsèquement une non linéarité optique de 3ème ordre élevée, a été étudiée. Il a été montré qu'il est possible de contrôler le gain et la non linéarité de matériaux dopés grâce à la corrélation établie entre l'analyse structurale et l'étude des propriétés spectroscopiques, de gain et de non linéarité qui dépendent des probabilités de transition 4f –4f. L'ensemble des résultats permet de mieux comprendre et prédire la variation de l'indice non linéaire d'un matériau amplificateur.

Page generated in 0.0324 seconds