• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 7
  • 1
  • 1
  • 1
  • Tagged with
  • 27
  • 27
  • 14
  • 13
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

TAMANHOS ELEMENTARES REPRESENTATIVOS DE ATRIBUTOS DO SOLO VIA ATENUAÇÃO DE RAIOS GAMA E TOMOGRAFIA COMPUTADORIZADA

Borges, Jaqueline Aparecida Ribaski 11 September 2015 (has links)
Made available in DSpace on 2017-07-21T19:25:49Z (GMT). No. of bitstreams: 1 Jaqueline Ap Borges.pdf: 4346896 bytes, checksum: 7cddb136f61196f7c1bd6d777eaee0bc (MD5) Previous issue date: 2015-09-11 / In this study, the Computed Tomography (CT) and gamma-ray attenuation (GRA) techniques were used in the investigation of representative sample sizes for attributes related to soil structure. First of all, the representative elementary length (REL) for experimental measurements of soil mass attenuation coefficient (μes), of samples from a sandy and a clayey soil, was analyzed. The study was conducted with two radioactive sources (241Am and 137Cs), three collimators (2–4 mm diameters), and 14 thickness (x) samples (2–15 cm). From these analyzes, it was possible to identify an ideal thickness range for each of the studied sources (2-4 cm and 12-15 cm for the sources of 241Am and 137Cs, respectively). The application of such results in representative elementary area evaluations, in clayey soil clods via CT, indicated that experimental soil mass attenuation coefficient average values obtained for x>4 cm and source 241Am might induce the use of samples which are not large enough for soil bulk density evaluations. Subsequently, μCT images with a total volume of 39×39×33 mm3 and spatial resolution of 60 μm were used for macroporous system morphological characterization of a Rhodic Ferralsol with clayey texture, under no-till (NT) and conventional till (CT) systems. Attributes as macroporosity (MAP), number of macropores (NMAP), tortuosity (τ) and connectivity (C) of the pores were assessed. The C degree was estimated based on the Euler-Poincaré characteristic (EPC). Once 3D images enable the study of these attributes in different sample volumes, the proposed study is ideal for the analysis of representative elementary volume (REV). Usually, the selection of subvolumes for REV analysis occurs concentrically to a small volume or in adjacent positions. Here, we introduced a new method for selecting the positions of subvolumes, which are randomly chosen within the total image volume (random selection). It was observed that higher fluctuations in amplitude of each analyzed property values occurred for smaller subvolumes and random selection. When these positions are randomly selected, all regions of the sample have the same probability of occurrence. Thus, the subvolumes can be selected from regions that exhibit similar characteristics, or which are quite different from each other. The results allowed the study of each of these attributes in function of the analyzed sample volume. Such analysis enabled the identification of a REV for MAP and τ measurements for both soils. However, NMAP and CEP showed no indication of stabilization within the total sample volume analyzed (39×39×33 mm3). From this study, it was possible to detect the influence of each management systems (NT and CT) on the macroporous system. In general, results obtained for soil under PC showed higher regularity, which is probably due to its homogenization induced by the plowing, conducted twice a year. / No presente estudo, as técnicas de tomografia computadorizada (TC) e atenuação de raios gama (AGR) foram utilizadas na investigação do tamanho representativo de amostras para atributos referentes à estrutura do solo. Primeiramente, foi analisado o comprimento elementar representativo (CER) de amostras de um solo de textura arenosa e outro de textura argilosa para medidas experimentais do coeficiente de atenuação de massa do solo (μes). O estudo foi realizado com duas fontes radioativas de raios gama (241Am e 137Cs), três aberturas de colimadores circulares (2-4 mm) e 14 espessuras (x) distintas de amostras deformadas de solo (2-15 cm). A partir destas análises foi possível identificar um intervalo de espessura ideal para cada uma das fontes estudadas (2–4 cm e 12–15 cm para as fontes de 241Am e 137Cs, respectivamente). A aplicação dos resultados obtidos para a fonte de 241Am, e solo argiloso, em avaliações de área elementar representativa (AER) para medidas de densidade do solo (ρs) via TC, indicaram que os valores médios de μes para x>4 cm podem induzir ao uso de amostras com tamanho não representativo. Na sequência, imagens de microtomografia de raios X (μTC), com volume total de 39×39×33 mm3 e resolução espacial de 60 μm, foram utilizadas para a caracterização micromorfológica do sistema macroporoso de um Latossolo vermelho de textura argilosa, submetido aos sistemas de manejo de plantio direto (PD) e plantio convencional (PC). Foram analisados atributos físicos como macroporosidade (MAP), número de macroporos (NMAP), tortuosidade (τ) e conectividade (C) dos poros. O grau de C dos poros foi estimado a partir da característica de Euler-Poincaré (CEP). Uma vez que imagens 3D possibilitam o estudo destes atributos em diferentes volumes de amostra, o estudo proposto é ideal para a análise de volumes elementares representativos (VERs). Geralmente, a seleção dos subvolumes para análises de VER se dá concentricamente a um volume de origem ou em posições adjacentes a este. Neste trabalho foi introduzida uma nova forma de seleção da posição dos subvolumes, os quais são selecionados randomicamente dentro do volume total da imagem (seleção aleatória). Observou-se que as maiores amplitudes de flutuações nos valores de cada atributo analisado ocorreram para os subvolumes menores quando selecionados de forma aleatória, em comparação à seleção centralizada. Quando estas posições são selecionadas aleatoriamente, todas as regiões da amostra têm a mesma probabilidade de ocorrência. Com isso, os subvolumes podem ser selecionados em regiões que apresentem características similares, ou então, que sejam muito diferentes umas das outras. Os resultados permitiram o estudo de cada um destes atributos em função do volume de amostra analisado. Tais análises possibilitaram a identificação de um VER para medidas de MAP e τ para os dois solos estudados. No entanto, a NMAP e a CEP não apresentaram indícios de estabilização até o volume total de amostra analisado (39×39×33 mm3). Quanto aos dois sistemas de manejo avaliados (PD e PC), foi possível detectar a influência de cada um deles na estrutura macroporosa do solo. De uma forma geral, o solo sob PC apresentou maior regularidade nos resultados obtidos, o que se deve à homogeneização do mesmo induzida pelo revolvimento do solo realizado duas vezes ao ano.
22

Estudo semianalítico da qualidade de imagem e dose em mamografia / Semianalytical study of image quality and dose in mamography

Tomal, Alessandra 24 February 2011 (has links)
Neste trabalho, foram desenvolvidos modelos semianalíticos para estudar os parâmetros de qualidade da imagem (contraste objeto, SC, e razão contraste-ruído, CNR) e a dose glandular normalizada (DgN ) em mamografia convencional e digital. As características de 161 amostras de tecidos mamários (coeficiente de atenuação linear e densidade) e os espectros de raios X mamográficos foram determinados experimentalmente, visando construir uma base de dados consistente destas grandezas para serem utilizadas nos modelos. Os coeficientes de atenuação linear foram determinados utilizando um feixe de raios X polienergético e um detector de Si(Li), e as densidades foram medidas utilizando o método da pesagem hidrostática. Os espectros de raios X de um equipamento industrial, que simula as qualidades de radiação de mamografia, foram medidos utilizando detectores de Si(Li), CdTe e SDD. A resposta de cada detector foi determinada por simulação Monte Carlo (MC). Os modelos semianalíticos desenvolvidos neste trabalho permitem calcular a deposição de energia na mama e no receptor de imagem, e foram utilizados para estudar o SC, a CNR e a DgN, para diferentes tipos de mama (espessura e glandularidade) e características do espectro incidente (combinação ânodo/filtro, potencial do tubo e camada semirredutora), bem como permitem avaliar a figura de mérito (FOM) em mamografia convencional e digital. Os resultados de coeficiente de atenuação e densidade para os diferentes grupos de tecidos mamários, mostram que os tecidos normais fibroglandulares e neoplásicos possuem características similares, enquanto tecidos normais adiposos apresentam menores valores destas grandezas. Os espectros medidos com cada detector, e devidamente corrigidos por suas respostas, mostram que os três tipos de detectores podem ser usados para determinar espectros mamográficos. Com base nos resultados de SC e CNR, foram estimados limites de detecção de nódulos em mamografia convencional e digital, que se mostraram similares entre si. Os resultados de SC, CNR e DgN obtidos também destacam a importância da escolha do modelo da mama e da base de dados de coeficiente de atenuação e espectros de raios X utilizados, uma vez que estes são responsáveis por uma grande variação nas grandezas estudadas. Além disso, os resultados de FOM mostram que, para mamas finas, a combinação Mo/Mo, tradicionalmente utilizada, apresenta o melhor desempenho, enquanto as combinações W/Rh e W/Ag são as mais indicadas para mamas espessas. Para mamas de espessuras médias, a melhor combinação depende da técnica utilizada (convencional ou digital). Finalmente, verificou-se que os modelos semianalíticos desenvolvidos permitem a obtenção de resultados de forma prática e rápida, com valores similares aos obtidos por simulação MC. Desta forma, estes modelos permitirão estudos futuros a respeito da otimização da mamografia, para outros tipos de mama e condições de irradiação. / In this work, semianalytical models were developed to study the image quality parameters (subject contrast, SC, and contrast-to-noise ratio, CNR) and the normalized average glandular dose (DgN) in conventional and digital mammography. The characteristics of 161 breast tissue samples (linear attenuation coefficient and density), and the mammographic x-ray spectra were determined experimentally, aiming to establish a consistent experimental database of these quantities to be used in the models. The linear attenuation coefficients were determined using a polyenergetic x-ray beam and a Si(Li) detector, and the densities were measured using the buoyancy method. The x-ray spectra from an industrial equipment, which reproduces the mammographic qualities, were measured using Si(Li), CdTe and SDD detectors. The responses of the detectors were determined using Monte Carlo (MC) simulation. The semianalytical models developed in this work allow computing the energy deposited in the breast and in the image receptor, and they were employed to study the SC, CNR and DgN, for different types of breast (thickness and glandularity) and incident x-ray spectra (anode/filter combination, tube potential and half-value layer). These models also allow evaluating the figure of merit (FOM) for conventional and digital mammography. The results of attenuation coefficient and density for the tissues analyzed show similar characteristics for the normal fibroglandular and neoplasic breast tissues, while the adipose tissue presents lower values of these quantities. From the x-ray spectra obtained using each detector, and corrected by their respective responses, it is observed that the three types of detectors can be used to determine mammographic spectra. Detection limits for nodules were estimated from the results of SC and CNR, and they were similar for both cases. The results of SC, CNR and DgN also show the importance of the choice of the breast model, and of the database of attenuation coefficient of breast tissues and x-ray spectra, since they largely influence the studied quantities. Besides, the results for FOM show that, for thin breasts, the Mo/Mo spectrum exhibits the better performance, while the W/Rh and W/Ag spectra are recommended for thicker breasts. For average thickness breasts, the more indicated spectra depend on the employed technique (conventional or digital). Finally, it was verified that the semianalytical models developed in this work provided results in a fast and simple way, with a good agreement with those obtained by using MC simulation. Therefore, these models allow further studies, regarding optimization of mammography, for other breast characteristics and irradiation parameters.
23

Estudo semianalítico da qualidade de imagem e dose em mamografia / Semianalytical study of image quality and dose in mamography

Alessandra Tomal 24 February 2011 (has links)
Neste trabalho, foram desenvolvidos modelos semianalíticos para estudar os parâmetros de qualidade da imagem (contraste objeto, SC, e razão contraste-ruído, CNR) e a dose glandular normalizada (DgN ) em mamografia convencional e digital. As características de 161 amostras de tecidos mamários (coeficiente de atenuação linear e densidade) e os espectros de raios X mamográficos foram determinados experimentalmente, visando construir uma base de dados consistente destas grandezas para serem utilizadas nos modelos. Os coeficientes de atenuação linear foram determinados utilizando um feixe de raios X polienergético e um detector de Si(Li), e as densidades foram medidas utilizando o método da pesagem hidrostática. Os espectros de raios X de um equipamento industrial, que simula as qualidades de radiação de mamografia, foram medidos utilizando detectores de Si(Li), CdTe e SDD. A resposta de cada detector foi determinada por simulação Monte Carlo (MC). Os modelos semianalíticos desenvolvidos neste trabalho permitem calcular a deposição de energia na mama e no receptor de imagem, e foram utilizados para estudar o SC, a CNR e a DgN, para diferentes tipos de mama (espessura e glandularidade) e características do espectro incidente (combinação ânodo/filtro, potencial do tubo e camada semirredutora), bem como permitem avaliar a figura de mérito (FOM) em mamografia convencional e digital. Os resultados de coeficiente de atenuação e densidade para os diferentes grupos de tecidos mamários, mostram que os tecidos normais fibroglandulares e neoplásicos possuem características similares, enquanto tecidos normais adiposos apresentam menores valores destas grandezas. Os espectros medidos com cada detector, e devidamente corrigidos por suas respostas, mostram que os três tipos de detectores podem ser usados para determinar espectros mamográficos. Com base nos resultados de SC e CNR, foram estimados limites de detecção de nódulos em mamografia convencional e digital, que se mostraram similares entre si. Os resultados de SC, CNR e DgN obtidos também destacam a importância da escolha do modelo da mama e da base de dados de coeficiente de atenuação e espectros de raios X utilizados, uma vez que estes são responsáveis por uma grande variação nas grandezas estudadas. Além disso, os resultados de FOM mostram que, para mamas finas, a combinação Mo/Mo, tradicionalmente utilizada, apresenta o melhor desempenho, enquanto as combinações W/Rh e W/Ag são as mais indicadas para mamas espessas. Para mamas de espessuras médias, a melhor combinação depende da técnica utilizada (convencional ou digital). Finalmente, verificou-se que os modelos semianalíticos desenvolvidos permitem a obtenção de resultados de forma prática e rápida, com valores similares aos obtidos por simulação MC. Desta forma, estes modelos permitirão estudos futuros a respeito da otimização da mamografia, para outros tipos de mama e condições de irradiação. / In this work, semianalytical models were developed to study the image quality parameters (subject contrast, SC, and contrast-to-noise ratio, CNR) and the normalized average glandular dose (DgN) in conventional and digital mammography. The characteristics of 161 breast tissue samples (linear attenuation coefficient and density), and the mammographic x-ray spectra were determined experimentally, aiming to establish a consistent experimental database of these quantities to be used in the models. The linear attenuation coefficients were determined using a polyenergetic x-ray beam and a Si(Li) detector, and the densities were measured using the buoyancy method. The x-ray spectra from an industrial equipment, which reproduces the mammographic qualities, were measured using Si(Li), CdTe and SDD detectors. The responses of the detectors were determined using Monte Carlo (MC) simulation. The semianalytical models developed in this work allow computing the energy deposited in the breast and in the image receptor, and they were employed to study the SC, CNR and DgN, for different types of breast (thickness and glandularity) and incident x-ray spectra (anode/filter combination, tube potential and half-value layer). These models also allow evaluating the figure of merit (FOM) for conventional and digital mammography. The results of attenuation coefficient and density for the tissues analyzed show similar characteristics for the normal fibroglandular and neoplasic breast tissues, while the adipose tissue presents lower values of these quantities. From the x-ray spectra obtained using each detector, and corrected by their respective responses, it is observed that the three types of detectors can be used to determine mammographic spectra. Detection limits for nodules were estimated from the results of SC and CNR, and they were similar for both cases. The results of SC, CNR and DgN also show the importance of the choice of the breast model, and of the database of attenuation coefficient of breast tissues and x-ray spectra, since they largely influence the studied quantities. Besides, the results for FOM show that, for thin breasts, the Mo/Mo spectrum exhibits the better performance, while the W/Rh and W/Ag spectra are recommended for thicker breasts. For average thickness breasts, the more indicated spectra depend on the employed technique (conventional or digital). Finally, it was verified that the semianalytical models developed in this work provided results in a fast and simple way, with a good agreement with those obtained by using MC simulation. Therefore, these models allow further studies, regarding optimization of mammography, for other breast characteristics and irradiation parameters.
24

Caractéristiques et origines de la variabilité diurne des propriétés optiques / Characteristics and origins of the diel variability of optical properties

Ouhssain, Malika 25 April 2014 (has links)
Mon travail de thèse s’est développé, pour le cas particulier des observations satellitales à partir de l’orbite géostationnaire. Le but général a été de caractériser la variabilité diurne des propriétés optiques inhérentes (i.e. les coefficients d‘atténuation et de rétrodiffusion particulaire, cp et bbp) et apparentes (i.e. la réflectance, R) des eaux océaniques (« forme » du cycle diurne, amplitude, variations saisonnières, causes). Ces propriétés optiques déterminent le signal qu’un instrument embarqué à bord d’un satellite peut observer. Cette étude est une étape préliminaire permettant de comprendre la physique du problème, avant de pouvoir évaluer la possibilité de quantifier cette variabilité diurne à partir des observations satellitaires. La variabilité diurne de cp et bbp est donc étudiée en fonction des saisons définies selon les conditions physico-trophiques: le mélange, le bloom, son déclin, et l’oligotrophie. cp et bbp sont caractérisés par un cycle diurne, augmentation le jour et diminution la nuit, confirmant les tendances générales connues. Ce phénomène se produit durant toutes les saisons avec une variabilité intra-saisonnière qui différencie les cycles de cp et bbp: cp montre une amplitude plus large durant le bloom, contrairement à bbp les minima de cp et bbp sont synchronisés tandis que les maxima de bbp sont atteints 3 à 6 h avant ceux de cp, sauf pendant le bloom. L’augmentation journalière de bbp se reflète dans les changements de R. Toutefois, les résultats ont montré que l’inversion ne permet pas de reproduire l’augmentation journalière de bbp de façon satisfaisante. Les techniques d’inversion existantes ne sont pas adaptées pour une utilisation à haute fréquence. / My thesis is developed for the particular case of satellites observations from geostationary orbit. The overall aim was to characterize the diel variability of water inherent (i.e. the particulate beam attenuation and backscattering coefficients, cp and bbp) and apparent (i.e. reflectance, R) optical properties (“shape”of diel cycle, amplitude, seasonal variations, origins). These properties determine the signal which is observed from sensor aboard satellite. This study is a preliminary step in understanding the physical problem, before assessing the possibility of quantifying the diel variability from satellite observations. Diel variability of cp and bbp is studied by season, as defined by physical and trophic conditions: mixing, bloom proliferation, its decline, and oligotrophy. Both cp and bbp are characterized by a diel cycle of daytime increase and nighttime decrease, confirming known general trends. This occurs across all seasons, but intra-seasonal variability differed between cp and bbp cycles: unlike bbp, cp show larger amplitude of diurnal variation during the bloom cp and bbp minima are synchronized while bbp minima are attained 3-6 h before those of cp, except during the bloom. Daily changes of R are consistent with the variations of bbp. Nevertheless, it is still difficult to reproduce the diurnal increase of bbp by inversion of R. The differences observed between in situ and modeled values of bbp suggest that the performance of inversion is degraded when it is used at high frequency.
25

Development of a computational method for determining gamma energy escape from calorimeters at CLAB

Mehic, Amela January 2022 (has links)
Swedish Nuclear Fuel and Waste Management Company- SKB has conducted measurement campaigns at the Swedish central interim storage facility for spent nuclear fuel- CLAB over the years, extending from year 2003 to 2019 where the gamma energy escape was acquired. At CLAB the spent nuclear fuel assembly is inserted into the calorimeter; device intended to measure temperature increase due to decay heat from the fuel assembly. The calorimetric construction is surrounded by water the medium in which the temperature deviations occur and thus are also measured by the calorimeter. However, there is some leakage of gamma energy from the calorimetric construction and does not contribute to the heating of the water. Therefore, only considering the calorimetric measurements is not enough to estimate the total decay heat in the fuel assembly since these measurements fail to account for the gamma escape. Measurements of gamma energy escape acquired over the years at CLAB were observed to have some tendencies that where questionable, mainly some stochastic behavior indicating that their uncertainty was profound. In the scope of the thesis a computational method was developed to calculate the gamma energy escape and thus assist in determining which measurements to discard. Combination of two programs were used one being Spent Nuclear fuel- SNF and the second Monte Carlo N particle Simulator- MCNP, to obtain the computational gamma energy escape for different fuel assemblies and cooling times- CTs. It was established that the escape had a range between 1-3,5% and that it had a dependency on CT, fuel assembly type and operational history. Calculated radial exponential decay coefficient for fuel assemblies of the medium; water had also a clear dependency on CT where values of the coefficient increased over CT. Normalized gamma energy distribution over a rotation around the fuel assembly was calculated and it showed that the assembly tended to have the highest radiation coming from its corner rods. The verification of the computational gamma escape results with corresponding measurements yielded that the agreement was quite good for the earlier measurement campaigns. However, deviation became evident after the 2007 campaign where the calculated values were underestimated compared to the measured.
26

[en] AGING EFFECTS AND LIFETIME EXPECTATION OF SUBMARINE OPTICAL CABLES / [pt] EFEITOS DO ENVELHECIMENTO E EXPECTATIVA DE VIDA ÚTIL EM CABOS ÓPTICOS SUBMARINOS

ROQUE ANDRE CIUFO POEYS 30 January 2024 (has links)
[pt] Os cabos ópticos submarinos estão distribuídos por boa parte dos oceanos ao redor do globo terrestre. Esses cabos começaram a ser instalados com maior intensidade na década de 90, apesar de o primeiro cabo submarino óptico ter sido instalado em 1982 nas ilhas Canárias. Atualmente a importância dos cabos ópticos submarinos é de grande relevância para as comunicações mundiais e vem crescendo muito ao longo do tempo com a demanda por serviços de internet, liderada hoje pelas grandes empresas de tecnologia e de exploração de mídia social, tais como Google, Amazon, Meta, etc. Hoje cerca de 99 por cento de todo o tráfego da comunicação mundial da internet passa pelos cabos submarinos. Os custos para implantação desses cabos são muito altos e, portanto, prover alternativas para a ampliação da sua duração para um período maior do que a sua expectativa de vida útil representa um ganho considerável para todos. Considera-se atualmente pelos fabricantes e organismos de padronização internacional, como o ITU-T (União Internacional de Telecomunicações), uma expectativa média de vida útil de 25 anos. Esta expectativa de vida útil dada para os cabos ópticos foi a principal motivação para o desenvolvimento dessa pesquisa, cujos objetivos visam apresentar evidências que indiquem que a tendência de vida útil dos cabos ópticos submarinos pode superar os 25 anos previstos, e dessa forma contribuir para o atendimento da crescente demanda por transmissão de dados no mundo impulsionada pelos serviços de Internet. A metodologia adotada foi coletar dados de medições com o OTDR em cabos ópticos submarinos ao longo de 24 anos e avaliar a degradação sofrida pelo coeficiente de atenuação em dB/km ao longo do tempo das fibras ópticas dos cabos em operação, e comparar com a degradação sofrida pelos cabos sobressalentes, e avaliar também a degradação das perdas nas emendas submarinas e a sua correlação com a profundidade de instalação no mesmo período. As análises foram realizadas através da avaliação das curvas em arquivos na extensão .Sor obtidas com as medições realizadas pelo OTDR. Os resultados obtidos demostraram que os cabos ópticos em operação sofreram degradações compatíveis com os valores esperados e dados pelo ITU-T, mas também mostraram através da análise de curvas de tendência, que a degradação tem um comportamento logarítmico, e a projeção da curva de tendência para os próximos anos indicou que esses cabos poderão continuar em operação por muito mais anos do que os 25 anos, dados como limite anterior. Foi observado também que a penalidade de potência dada pela perda nas emendas é muito superior a degradação somente nas fibras ópticas, que existe uma correlação positiva entre a profundidade das caixas de emenda e a degradação na emenda e que os cabos sobressalentes degradam muito mais que os cabos em operação. / [en] Submarine optical cables are distributed over most of the oceans around the globe.These cables were installed with greater intensity in the 1990s, despite the fact that the firstoptical submarine cable was installed in 1982 in the Canary Islands. Currently, theimportance of submarine optical cables is very relevant for world communications and hasbeen growing a lot over time with the demand for internet services, led today by largetechnology and social media companies such as Google, Amazon, Meta, etc. Today around 99 percent of all world internet communication goes through undersea cables. The costs forimplanting these cables are very high and, therefore, to provide alternatives for optimizingtheir use by extending their duration for a period longer than their expected useful life,given by international standardization bodies, such as the ITU-T (InternationalTelecommunications Union), and by the manufacturers, which currently is 25 years, is ahuge gain for everyone. The life expectancy given for optical cables was the mainmotivation for the development of this research, whose objectives aim to present evidencethat indicates that the useful life trend of submarine optical cables can reach much morethan the 25 years predicted and in this way contribute to meeting the growing demand fordata transmission in the world, driven by Internet services. The adopted methodology wasto collect measurement data with the OTDR in submarine optical cables over 24 years andto evaluate the degradation suffered by the attenuation coefficient in dB/Km over time ofthe optical fibers of the cables in operation and to compare with the degradation sufferedby the spare cables, and also evaluate the degradation of the losses in the underwater splicesand its correlation with the depth of installation in the same period. The analyzes werecarried out by evaluating the .Sor curves obtained with the measurements performed by theOTDR. The conclusions showed that the optical cables in operation suffered degradationscompatible with the expected values and given by the ITU-T, but also showed through theanalysis of trend curves, that the degradation has a logarithmic behavior, and the projectionof the trend curve for the coming years indicated that these cables could continue to operatefor many more years than the 25 years given as the previous limit. It was also observed thatthe power penalty given by the loss in the splices is much higher than the degradation inthe optical fibers alone, that there is a positive correlation between the depth of the spliceboxes and the degradation in the splice, and that the spare cables degrade much more thanthe cables in operation.
27

Propriedades de atenuação da radiação: influência da textura e tamanho de agregado do solo

Tech, Lohane 26 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-06-06T14:39:52Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tech, Lohane.pdf: 2007649 bytes, checksum: ed3cf3b82a08ab6680c21d8be8071469 (MD5) / Made available in DSpace on 2018-06-06T14:39:52Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Tech, Lohane.pdf: 2007649 bytes, checksum: ed3cf3b82a08ab6680c21d8be8071469 (MD5) Previous issue date: 2018-02-26 / No presente trabalho foram analisadas 25 solos com diversas texturas, do estado do Paraná Brasil. Com o intuito de avaliar os parâmetros de interação da radiação com os solos, as amostras foram submetidas a análise semi-quantitativa por fluorescência de raios X (FRX) por dispersão de energia a fim de se obter os teores dos óxidos que compunham o solo. Dois tamanhos de partículas foram analisados, sendo eles: diâmetro de 45 μm, que é o padrão recomendado pelo fabricante do equipamento de FRX, e diâmetro de 2-1 mm. O teor dos óxidos, o coeficiente de atenuação de massa (⁄), a seção de choque molecular (), a seção de choque atômica (), a seção de choque eletrônica (), o número atômico efetivo () e a densidade eletrônica (), foram analisadas para os 25 solos para os dois tamanhos de partículas. Os resultados mostraram diferenças nos teores de óxidos dos solos entre um tamanho de agregado e outro, constatando mudanças nas porcentagens do óxidos de Al2O3, SiO2 e Fe2O3. Como consequência, houve alteração nos valores dos outros parâmetros analisados, as seções de choque, o número atômico efetivo e a densidade eletrônica. A seção de choque molecular e a densidade eletrônica mostrou dependência com o teor dos óxidos Al2O3 e SiO2, que são encontrados em maior porcentagem nos solos arenosos e nos solos com textura franco, para os dois tamanhos de agregados. A seção de choque atômica mostrou dependência com o número total de unidades de fórmulas moleculares presentes na composição do solo. Já os parâmetros restantes, coeficiente de atenuação de massa, seção de choque eletrônica e número atômico efetivo mostraram dependência com o óxido Fe2O3, que é encontrado em maior teor nas amostras com textura mais argilosa, para os dois tamanhos de agregados. Desta forma, observou-se dependência da textura e do tamanho de partículas ambas com a composição química elementar porque no primeiro caso, diferentes texturas são relacionadas a composição mineral e elementar nos diferentes solos e a segunda devido a conformação dos agregados nos dois conjuntos analisados. / This study analysed 25 soil samples from the State of Paraná, Brazil, with different textures. Aiming at evaluating the parameters of radiation interaction with the matter, the samples were submitted to the semi-quantitative analysis using energy dispersive X-ray (XRF) fluorescence, to obtain the content of oxides contained in the soil mixture. Two particle sizes were analysed, being: the 45 μm, wich is the standard required by the manufacturer of the X-ray fluorescence equipment, and the 2-1mm. The oxide content, mass attenuation coefficient (⁄), molecular cross section (), atomic cross section (), electronic cross section (), effective atomic number () and the electronic density () were analysed in the 25 samples and for the two particle sizes. The results showed differences in the soil oxide content between one aggregate size and the other, revealing changes in the percentage of the Al2O3, SiO2 and Fe2O3 oxides. With the difference observed, there was change in the values of other parameters under analysis, the cross sections, the effective atomic number and the electronic density. The molecular cross section and the effective electronic density showed dependence on the content of Al2O3 and SiO2 oxides, which were found in higher percentages in sandy and loam soils, for both aggregate sizes. The atomic cross section was seen to present dependence on the total number of molecular formula units contained in the soil composition. While the remaining parameters, mass attenuation coefficient, electronic cross sections and the effective atomic number showed dependence on the Fe2O3 oxide, whose higher contents were found in the clay textured samples, for both aggregate sizes. In this way, it was observed texture and size dependency, both with the elementary chemical composition because in the first case, different textures are related to elementary and mineral composition in the different soils and the second due to the conformation of the aggregated in both analyzed arrays.

Page generated in 0.0531 seconds