• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 50
  • 9
  • 8
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 124
  • 124
  • 47
  • 39
  • 34
  • 29
  • 24
  • 19
  • 15
  • 15
  • 14
  • 13
  • 12
  • 12
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

The Beta Decay of 79,80,81Zn and Nuclear Structure around the N=50 Shell Closure

Padgett, Stephen William 01 December 2011 (has links)
This dissertation reports on new information in the [beta minus] decay of the neutron-rich nucleus 81Zn, which populates states in its daughter nucleus 81Ga. This includes new [gamma]-ray transitions in the daughter nucleus, 81Ga, as well as a [beta]-delayed neutron branching ratio. This isotope was produced at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory through the Isotope Separation Online technique. They are fission fragments from proton-induced fission on a uranium carbide target. These fission fragments are ionized and both mass and isotopically separated before arriving at the Low Energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS). The [gamma]-ray and [beta] electron emissions from the decays are measured and analyzed in this work. A new [beta]-delayed neutron branching ratio is reported for this decay, which is in agreement with recent theoretical values. The core excited states in the daughter nucleus, 81Ga, populated through allowed Gamow-Teller decays are analyzed. A trend in core excited states with other N=50 isotones indicates an increasing gap between a deeply bound neutron hole and the valence neutron above the N=50 gap upon moving towards doubly magic 78Ni. This dissertation also reports on additions to the decay schemes of 79Zn and 80Zn decays. Their decay level schemes have been expanded upon and an improved picture of the total allowed Gamow-Teller decay strength is known from 79Zn to 81Zn. This work presents an improved, albeit still incomplete, picture of the energy of states populated through Gamow-Teller decays from below to above the N=50 shell gap in zinc isotopes.
62

Recherche de la nature du neutrino avec le détecteur SuperNEMO : simulations optiques pour l'optimisation du calorimètre et performances attendues pour le 82Se / Search of the neutrinos's nature for the SuperNEMO detector : optical simulations for the calorimeter's optimizations and expected performances for 82Se

Huber, Arnaud 29 September 2017 (has links)
Le démonstrateur de SuperNEMO est un détecteur de nouvelle génération pour la recherche de la décroissance double bêta sans émission de neutrinos. Comme son prédécesseur NEMO3, la technique expérimentale utilisée associe un trajectographe et un calorimètre afin de pouvoir identifier les électrons des décroissances double bêta tout en permettant la différenciation des différentes composantes du bruit de fond. Le démonstrateur est en cours d’installation au Laboratoire Souterrain de Modane et commencera à prendre des données à la fin de l’année 2017 afin d’atteindre une sensibilité supérieure à 1026 ans sur la demi-vie de la décroissance ββ0ν du 82Se dans la version finale du détecteur (100 kg d’isotopes pour une exposition totale de 5 ans).Ce travail de thèse a consisté à étudier la réponse en énergie et en temps des modules optiques du calorimètre (association d'un scintillateur plastique et d'un photomultiplicateur). Une simulation optique basée sur le logiciel GEANT4 a été développée afin de reproduire l'ensemble des phénomènes optiques ayant lieu au sein du scintillateur et du photomultiplicateur : scintillation, atténuation de Birks, émission Cerenkov, propagation et collection des photons. Ces travaux ont abouti à la mise au point de termes correctifs de hautes précisions sur l’énergie afin que le Monte Carlo de SuperNEMO soit au plus proche des données. Ces corrections ont alors été appliquées dans le cas du démonstrateur afin d’étudier l'impact sur la sensibilité au processus ββ0ν du 82Se. Ces simulations optiques ont également été étendues jusqu’à la modélisation de la forme temporelle des signaux du calorimètre. / The SuperNEMO demonstrator is a next generation experimental device, looking for neutrinoless double beta decay. Like its predecessor NEMO3, the experimental technique employed is based on a combination of a tracker and a calorimeter to identify the electrons from the double beta decay process while allowing the differentiation and identification of the different background components. The SuperNEMO’s demonstrator is currently being installed at the Modane Underground Laboratory and will begin to register data by the end of 2017. The aim is to reach a sensivity greater than 1026 years on the half-life of the 82Se ββ0ν process in the final version of the detector (100 kg of isotopes for a 5 years’ total exposure).This thesis contribution to the SuperNEMO, consisted in studying the energy and time response of the calorimeter optical modules (association of a plastic scintillator and a photomultiplier). To do so, an optical simulation based on the GEANT4 software was developed, which enabled to reproduce and simulate all the optical phenomena inside a scintillator and a photomultiplier: scintillation, Birks attenuation, Cerenkov emission, propagation and photon collection. The outcome and result of this thesis has been to develop high-precision corrective factors on the energy linked, so that the Monte-Carlo’s SuperNEMO is closest to the real data experimental records. These corrections were applied to the demonstrator simulation in order to study the impact on the ββ0ν sensitivity. These optical simulations have also been extended to the modeling of the temporal shape of the calorimeter signals.
63

Study and selection of scintillating crystals for the bolometric search for neutrinoless double beta decay / Etude et sélection de cristaux scintillants pour la recherche de la double désintégration bêta sans neutrino avec des bolomètres scintillants

Zolotarova, Anastasiia 24 September 2018 (has links)
L'observation de la désintégration double bêta sans émission de neutrino (0ν2β) fournirait des informations essentielles sur la nature du neutrino et son échelle de masse absolue. Ce processus consiste en la transformation simultanée de deux protons en deux neutrons avec l'émission de deux électrons et aucun neutrino. Cette transition n'est possible que si les neutrinos sont égaux aux antineutrinos (nature Majorana du neutrino). Les recherches pour une désintégration à ce point rare représentent un défi technique complexe, car les expériences de prochaine génération visent des sensibilités de l'ordre de 10^27-10^28 ans afin d'avoir un potentiel de découverte élevé. Cette thèse est focalisée sur les projets LUMINEU et CUPID-Mo, développant la technique des bolomètres scintillants pour la recherche de désintégration 0ν2β avec le radio-isotope 100Mo.Les bolomètres sont des détecteurs cryogéniques mesurant l'énergie des particules déposées via un changement de température dans l'absorbeur. Si des cristaux scintillants sont utilisés comme absorbeurs, les signaux lumineux peuvent être enregistrés avec un bolomètre auxiliaire, sensible à l'énergie totale déposée par les photons de scintillation. Une telle configuration permet de séparer les particules α des γ/β, en rejetant le fond le plus difficile. La technologie des bolomètres scintillants est décrite en détail comme une option pour une future expérience cryogénique à l'échelle d'une tonne, appelée CUPID, qui peut couvrir complètement la région de masses de neutrinos dans la hiérarchie inversée. / Neutrinoless double beta (0ν2β) decay is a process of great interest for neutrino physics: its observation would provide essential information on neutrino nature and its absolute mass scale. This process consists of the simultaneous transformation of two protons into two neutrons with the emission of two electrons and no neutrino, implying the violation of the total lepton number. Such transition is possible only if neutrinos are equal to antineutrinos (Majorana particles). The searches for such a rare decay are becoming a complicated technical challenge, as next generation of 0ν2β experiments aim at sensitivities of the order of half-life at 10^27-10^28 yr. This thesis is focused on LUMINEU and CUPID-Mo projects, developing the scintillating bolometers technique for 0ν2β decay search with 100Mo with Li2MoO4 crystals. Bolometers are cryogenic detectors measuring the deposited particle energy as a change of temperature in the absorber. The use of scintillating crystals allows to perform discrimination of α particles from γ/β ones due to different light output of these two particle types, rejecting the most challenging background. The scintillating bolometers technology is described in details as an option for a future ton-scale cryogenic experiment, named CUPID, which can completely cover the inverted hierarchy region of neutrino masses.
64

Neutrino physics with SoLid and SuperNEMO experiments / Physique du neutrino avec les expériences SoLid et SuperNEMO

Boursette, Delphine 13 September 2018 (has links)
Les neutrinos sont les particules fondamentales de matière les plus abondantes dans l’univers. Ils ont été détectés pour la première fois en 1956. Depuis lors, plusieurs expériences ont tenté de percer leurs mystères. Ils n’interagissent que par interaction faible, ils sont donc difficiles à détecter. On sait aujourd’hui qu’ils ont une masse très faible, et qu’ils peuvent osciller entre trois saveurs leptoniques. Cependant, de nombreuses questions perdurent sur leur masse, leur nature ou encore l’existence de neutrinos stériles. Cette thèse appréhende ces deux dernières questions à l’aide de deux expériences différentes : SuperNEMO et SoLid. Le but de l’expérience SuperNEMO est de rechercher la nature du neutrino, c’est-à-dire s’il est sa propre anti-particule (particule de Majorana) ou non (particule de Dirac). Pour cela, on cherche à détecter des doubles désintégrations bêta sans émission de neutrinos car ce processus n’est possible que si les neutrinos sont des particules de Majorana. Des feuilles sources de l’émetteur double bêta ⁸²Se seront installées au centre du démonstrateur SuperNEMO qui est actuellement en construction au Laboratoire Souterrain de Modane. Ce détecteur est composé d’une chambre à fils pour détecter les traces des deux électrons émis lors des désintégrations et d’un calorimètre pour mesurer leurs énergies. La mesure de la double désintégration bêta sans émission de neutrinos est très compliquée car si ce processus existe, il est extrêmement rare. Par conséquent, un travail important est fait pour réduire le bruit de fond des rayons cosmiques ou de la radioactivité naturelle. Dans cette thèse, des simulations des différents bruits de fonds ont été faites pour comprendre leur impact sur la mesure de l’énergie des électrons issus de la double désintégration bêta du ⁸²Se. Il est montré que la radioactivité du verre des photomultiplicateurs ne sera pas négligeable mais qu’elle pourra être mesurée précisément dans certains canaux d'analyse. Des feuilles de cuivre ont aussi été simulées à la place des sources de ⁸²Se pour montrer qu’elles peuvent aider à contrôler le bruit de fond efficacement. Suite à ces travaux, il a été décidé d’installer des feuilles de cuivre parmi les sources de ⁸²Se. La deuxième expérience sur laquelle porte cette thèse est l’expérience SoLid qui cherche à prouver l’existence de neutrinos stériles. Plusieurs anomalies expérimentales pourraient être expliquées par des oscillations d'antineutrinos de réacteurs vers des neutrinos stériles. Le détecteur SoLid cherche à mettre en évidence un signal d'oscillation auprès du réacteur BR2 en Belgique en mesurant le flux d’antineutrinos en fonction de leur énergie et de la distance parcourue, grâce à une grande segmentation. La détection des antineutrinos de réacteur se fait par désintégration bêta inverse. L’interaction d’un antineutrino se traduit donc par l’émission en coïncidence d’un positron et d’un neutron. Les positrons sont détectés dans des cubes de plastique scintillant en PVT et les neutrons sont détectés par des feuilles de ⁶LiF:ZnS posées sur chacun des cubes. Un premier prototype, SM1, a montré l’intérêt de cette technologie notamment pour discriminer les bruits de fonds. Une partie des travaux de cette thèse a consisté à développer et exploiter un banc de test afin d'optimiser la collection de lumière du détecteur pour améliorer la résolution en énergie de SoLid. En testant différents matériaux et différentes configurations du détecteur, les mesures sur le banc de test ont montré qu’une résolution en énergie de 14 % pouvait être atteinte pour le détecteur SoLid (contre 20 % pour le prototype SM1). Les améliorations proposées ont été prises en compte dans la construction du détecteur SoLid qui s’est achevée en 2017. Une analyse des premières données du détecteur est également présentée pour montrer la sensibilité de SoLid à la détection des antineutrinos de réacteur. / Neutrinos are the most abundant fundamental particles of matter in the Universe. They were detected for the first time in 1956. Since then, several experiments have tried to unveil their mysteries. They only interact weakly so they are difficult to detect. It is known that their masses are very low and that they can oscillate between three leptonic flavours. However, several questions remain about their masses, their nature or the existence of sterile neutrinos. This thesis addresses the last two questions with two different experiments: SuperNEMO and SoLid. The goal of the SuperNEMO experiment is to understand the nature of neutrinos, whether it is its own antiparticle (Majorana particle) or not (Dirac particle). This is investigated by searching for neutrinoless double beta decay as this process is possible only if neutrinos are Majorana particles. Source foils of the double beta emitter ⁸²Se are installed at the center of the SuperNEMO demonstrator which is being assembled at the Modane Underground Laboratory. This detector is composed of a wire chamber to detect the tracks of the two electrons emitted in the decays and a calorimeter to measure their energies. Neutrinoless double beta decay measurement is very difficult because if this process exists, it is extremely rare. An important work has thus to be done to decrease backgrounds from cosmic rays or natural radioactivity. In this thesis, different backgrounds have been simulated to understand their impact on the measurement of the energy of the two electrons from ⁸²Se double beta decay. It is shown that radioactivity from photomultipliers glasses will not be negligible but it will be possible to measure it precisely in dedicated channels. Copper foils have also been simulated in the source strips to demonstrate that they can help to control efficiently the backgrounds. Following this work, it has been decided to install copper foils in addition to ⁸²Se foils. The second experiment investigated in this thesis is the SoLid experiment which is looking for the existence of sterile neutrinos. Several experimental anomalies could be explained by oscillations of reactor antineutrinos toward sterile neutrinos. The SoLid detector is looking for an oscillation signal at the Belgian BR2 reactor by measuring the antineutrino flux as a function of their energy and their traveling distance thanks to a fine segmentation. The reactor antineutrinos are detected via inverse beta decay. The antineutrino interaction signal is thus the emission in coincidence of a positron and a neutron. Positrons are detected by plastic scintillator cubes in PVT and neutrons are detected by ⁶LiF:ZnS sheets placed on 2 faces of each cube. A first prototype, SM1, has demonstrated the advantages of this technology, particularly to discriminate backgrounds. A part of the work of this thesis consisted in developing and exploiting a test bench to optimize the light collection of the detector in order to improve the energy resolution of the SoLid detector. By testing different materials and configurations, the test bench measurement demonstrated that an energy resolution of 14 % can be achieved for SoLid phase I, while it was 20 % for the SM1 prototype. The improvements proposed have been taken into account for the SoLid detector construction that was achieved in 2017. An analysis of the first detector data is also presented to show SoLid sensitivity to reactor antineutrino detection.
65

Development of a high pressure xenon gas time projection chamber with a unique cellular readout structure to search for neutrinoless double beta decay / ニュートリノを伴わない二重ベータ崩壊探索のためのユニークなセル構造信号読み出し機構を持った高圧キセノンガスtime projection chamber の開発

Pan, Sheng 25 May 2020 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(理学) / 甲第22627号 / 理博第4616号 / 新制||理||1663(附属図書館) / 京都大学大学院理学研究科物理学・宇宙物理学専攻 / (主査)准教授 市川 温子, 教授 中家 剛, 准教授 窪 秀利 / 学位規則第4条第1項該当 / Doctor of Science / Kyoto University / DFAM
66

A study of neutron pairing correlations using the 136Ba(p, t) reaction

Jespere Calderone, Nzobadila Ondze January 2020 (has links)
>Magister Scientiae - MSc / Observation of neutrinoless double beta decay (0 ) is currently the only means by which one could establish the Majorana nature of neutrinos. Additionally, such an observation would determine the absolute neutrino mass scale. However, this requires that the matrix element for a given 0 decay process is accurately calculated. The objective of this project is to provide useful nuclear structure information that aim to improve future theoretical calculations for the nuclear matrix element (NME) of 136Xe 0 decay to 136Ba. We studied neutron pairing correlations in 134Ba using the 136Ba(p; t) reaction to stringently test the Bardeen-Cooper-Schrie er (BCS) approximation in the A = 136 mass region. This is because many theoretical calculations of the NME's for 0 decay are performed using the quasiparticle random phase approximation (QRPA), which uses the BCS approximation to describe the ground states of the even-even parent and daughter nuclei. Our results show a signi cant fragmentation of the neutron-pair transfer to excited 0+ states, implying a breakdown of the BCS approximation in this mass region.
67

Sensitivity enhancement of the CUORE experiment via the development of Cherenkov hybrid TeO₂ bolometers / Amélioration de la sensibilité de l'expérience CUORE par le développement de bolomètres de TeO₂ hybrides à “lumière Cherenkov

Novati, Valentina 21 November 2018 (has links)
CUORE est la plus grande expérience qui recherche la double désintégration bêta sans neutrino avec des bolomètres de TeO₂. La découverte de cette transition nucléaire aurait des conséquences décisives sur la scène actuelle de la physique. Les questions suivantes trouveraient une réponse : pourquoi la matière est-elle dominante dans l’Univers? Quelle est la masse du neutrino? Le neutrino est il un particule de Majorana ou de Dirac? Ce travail présente deux approches différentes pour l’amélioration de la sensibilité de CUORE en vue de sa prochaine phase : CUPID. Dans la première partie de ce travail, une étude du modèle thermique pour les bolomètres équipés avec des NTDs est présentée dans le but de mieux comprendre la réponse des détecteurs de CUORE. Les bolomètres sont des détecteurs extraordinaires utilisés pour un grand nombre d’applications en raison de leurs performances remarquables, mais leur modélisation et leur simulation sont loin d’être complètement comprises. Deux mesures ont été effectuées pour évaluer expérimentalement deux paramètres du modèle thermique : la conductance de la colle et celle entre les électrons et les phonons. Dans la deuxième partie de ce travail, la possibilité de détecter la faible lumière Cherenkov émise par le TeO₂ est étudiée à fin de rejeter des événements alpha, le fond principal de l’expérience CUORE. Le défi consiste dans la détection d’un signal de lumière de 100 eV à moyen d’un détecteur équipé avec un NTD qui a normalement un bruit de l’ordre de 100 eV. Cette question peut être résolue grâce à l’effet Neganov-Trofimov-Luke (NTL) qui a permis de baisser le seuil du détecteur de lumière et d'améliorer son rapport signal-sur-bruit. Cet effet exploite la présence d’un champ électrique pour amplifier les signaux thermiques des bolomètres. Le rejet complet du fond alpha a été prouvé avec un photo-bolomètre amélioré par l’effet NTL et couplé à un bolomètre de TeO₂ comme ceux utilisés par CUORE. Une solution convaincante pour le rejet de fond alpha a été démontrée en vue de l’expérience CUPID. / CUORE is the first tonne-scale experiment searching for the neutrinoless double beta decay with TeO₂ bolometers. The discovery of this nuclear transitionwould have decisive consequences on the present physics scene. The following questions would find an answer: why is matter dominant in the Universe? which is the neutrino mass? has the neutrino a Majorana or a Dirac nature? This work presents two different approaches for the enhancement of the CUORE sensitivity with a view to its upgrade: the CUPID experiment. In the first part, a study of the thermal model describing NTD-based bolometers is presented with the objective to achieve a better comprehension of the response of the CUORE detectors. Bolometers are amazing detectors used for a large number of applications because of their impressive high performance, but their modelisation and simulation is far to be completely understood. Two measurements have been performed for an experimental evaluation of two thermal-model parameters: the glue and the electron-phonon conductances. In the second part, the possibility to detect the tiny Cherenkov light emitted by TeO₂ to reject alpha events — the main background of the CUORE experiment — is studied. The challenge consists in the detection of a 100-eV light signal with a NTD-based light detector that usually is characterised by a baseline noise of the order of 100 eV. This issue is solved with the employment of the Neganov-Trofimov-Luke (NTL) effect to lower the energy threshold of the light detector and improve its signal-to-noise ratio. This effect exploits the presence of an electric field to amplify bolometric thermal signals. The full rejection of the alpha background has been proved with one NTL assisted photo-bolometer coupled to a CUORE-size TeO₂ bolometer. A convincing solution for the alpha background rejection has been demonstrated with a view to the CUPID experiment.
68

Monitorování energetické stupnice v neutrinovém experimentu KATRIN / Monitoring of the energy scale in the KATRIN neutrino experiment

Slezák, Martin January 2016 (has links)
The question of the absolute mass scale of neutrinos is of particular interest for particle physics, astrophysics, and cosmology. The KATRIN experiment (KArlsruhe TRItium Neutrino experiment) aims to address the effective electron antineutrino mass from the shape of the tritium β-spectrum with an unprecedented sensitivity of 0.2 eV/c2 . One of the major systematic effects concerns the experimental energy scale, which has to be stable at the level of only a few parts in a million. For its calibration and monitoring the monoener- getic electrons emitted in the internal conversion of γ-transition of the metastable isotope 83m Kr will be extensively applied. The aim of this thesis is to address the problem of KA- TRIN energy scale distortions and its monitoring in detail. The source of electrons based on 83m Kr embedded in a solid as well as the source based on gaseous 83m Kr are studied. Based on the experimental results an approach for the continuous stability monitoring is proposed. 1
69

The Tao and Zen of neutrinos: neutrinoless double beta decay in KamLAND-Zen 800

Li, Aobo 30 September 2020 (has links)
Neutrinoless Double Beta Decay(0𝜈𝛽𝛽) is one of the major research interests in neutrino physics. The discovery of 0𝜈𝛽𝛽 would answer persistent puzzles in the Standard Model of Elementary Particles. KamLAND-Zen is one of the leading efforts in the search of 0𝛽𝛽 and has acquired data from 745 kg of ^{136}Xe over 224 live-days. This data is analyzed using a Bayesian approach consisting of a Markov Chain Monte Carlo (MCMC) algorithm. The implementation of the Bayesian analysis, which is the focal point of this dissertation, yields a 90\% Credible Interval at T^{0𝜈}_{1/2} = 7.03 × 10^{25} years. Finally, a machine learning event classification algorithm, based on a spherical convolutional neural network (spherical CNN) was developed to increase the T^{0𝜈}_{1/2} sensitivity. The classification power of this algorithm was demonstrated on a Monte Carlo detector simulation, and a data driven classifier was trained to reject crucial backgrounds in the 0𝜈𝛽𝛽 analysis. After implementing the spherical CNN, an increase in T^{0𝜈}_{1/2} sensitivity of 11.0% is predicted. These early studies pave the way for substantial improvements in future 0𝜈𝛽𝛽 analyses.
70

Search for sterile neutrinos in β-decays / Recherche de neutrinos stériles dans les désintégrations β

Altenmüller, Konrad Martin 10 October 2019 (has links)
Le travail présenté dans cette thèse porte sur la recherche de neutrino stérile à l'aide de désintégrations β dans les expériences SOX et TRISTAN. Le neutrino stérile est une particule hypothétique, solidement établi théoriquement, qui ne prendrait part à aucune interaction fondamentale, gravité mise à part. Étant entendu que le neutrino stérile se mélange avec les neutrinos actifs connus, l'existence de ces premiers peut être étudiée directement en laboratoire. L'expérience SOX a été conçue pour explorer l'existence d'un neutrino stérile d'une masse autour de l'électronvolt (eV). Un neutrino stérile avec une telle masse permettrait d'expliquer plusieurs anomalies observées à courte distance de sources (quelques mètres) lors de mesures d'oscillations de neutrinos de basses énergies (quelques MeV). SOX avait pour projet d'utiliser le détecteur de neutrinos solaire déjà existant Borexino, et d'observer un signal d'oscillation vers le stérile à l'intérieur même du volume actif du détecteur. La source radioactive de 5.5 PBq et positionnée à 8.5 m du centre du détecteur, émettrait des antineutrinos électroniques via la désintégration β du ¹⁴⁴Ce et du ¹⁴⁴Pr. Une des clés de l'observation de cette oscillation, est la connaissance précise de l'activité de la source. Une telle activité peut être déterminée en mesurant la chaleur dégagée par la source. C'est la raison pour laquelle l'INFN Genova et la TUM ont développé conjointement un calorimètre dédié. La chaleur dégagée par la radioactivité est alors captée par un échangeur puis transmise à un circuit d'eau étroitement contrôlé. Le calorimètre a été assemblé, optimisé puis étalonné avec succès. La perte de chaleur du circuit fut déterminée lors des mesures d'étalonnage grâce à un chauffage électrique. Des variations des conditions expérimentales et une isolation thermique sophistiquée ont permis d'opérer avec des pertes de chaleur négligeables. Il a ainsi été démontré que la puissance thermique de la source pouvait être estimée, en 5 jours seulement, avec une précision supérieure à 0,2%. Malheureusement, le programme SOX a dû être annulé. Le projet TRISTAN, quant à lui, tend à démontrer l'existence d'un neutrino stérile avec une masse de l'ordre du kilo-électronvolt (keV). Si le neutrino stérile à l'eV tente d'apporter une réponse aux différentes anomalies observées lors de mesures d'oscillation, le neutrino stérile au keV, en tant que potentiel candidat matière noire. Le projet TRISTAN cherche à mesurer l'empreinte de ce nouvel état de masse sur le spectre du tritium dans le cadre de l'expérience KATRIN. Cette dernière vise à déterminer la masse effective du neutrino (actif) en mesurant l'extrémité du spectre de tritium avec une excellente résolution et un faible taux de comptage. Une fois la mesure achevée, le détecteur de KATRIN sera modifié afin d'effectuer une mesure différentielle et intégrale de l'ensemble du spectre en tritium: c'est le projet TRISTAN. Le détecteur actuel sera remplacé par un nouveau détecteur de silicium à dérive (SDD) de 3500 pixels permettant une résolution de 3% à 6 keV et pouvant supporter un taux de comptage montant jusqu'à 10⁸ coups par seconde, activité maximum attendue. Un prototype a été testé avec succès et une première mesure de tritium a été réalisé au spectromètre de masse neutrino Troitsk afin d'étudier les erreurs systématiques et de développer des méthodes d'analyses pertinentes. Un premier ajustement cohérent du spectre tritium différentiel acquis lors de cette installation, a démontré la faisabilité du projet. TRISTAN lui-même est toujours en cours de développement mais les caractérisations du détecteur et les études de systématiques sont plus qu'encourageantes pour la poursuite du projet. La première investigation de neutrino stérile avec le détecteur de TRISTAN sur le site de KATRIN est prévue après la mesure de masse, en cours à Karlsruhe, aux alentours de 2024. / The work presented in this thesis is about the sterile neutrino search with the two experiments SOX and TRISTAN based on the β-decay. Sterile neutrinos are theoretically well motivated particles that do not participate in any fundamental interaction except for the gravitation. With the help of these particles one could elegantly explain the origin of the neutrino mass, dark matter and the matter-antimatter asymmetry in the universe. As sterile neutrinos can mix with the known active neutrinos, they could be discovered in laboratory searches. The SOX experiment was designed to search for a sterile neutrino with a mass in the eV-range. This particular mass range is motivated by several anomalous observations at short-baseline neutrino experiments that could be explained by an additional oscillation with a length in the order of meters that arises from an eV-scale sterile neutrino. For SOX it was planned to use the existing Borexino solar neutrino detector to search for an oscillation signal within the detector volume. The neutrinos are emitted from a 5.5 PBq electron-antineutrino source made of the β-decaying isotopes ¹⁴⁴Ce and ¹⁴⁴Pr, located at 8.5 m distance from the detector center. For the analysis of the signal it is crucial to know the source activity. This parameter is determined by measuring the decay heat of the source with a thermal calorimeter that was developed by TUM and INFN Genova. The decay heat is measured through the temperature increase of a well-defined water flow in a heat exchanger that surrounds the source. The calorimeter was assembled, optimized and characterized. Heat losses were determined through calibration measurements with an electrical heat source. Adjustable measurement conditions and an elaborate thermal insulation allowed an operation with negligible heat losses. It was proven that the power of a decaying source can be measured with <0.2% uncertainty in a single measurement that lasts ~5 days. Unfortunately the SOX experiment was canceled after a technological problem rendered the source production with the required activity and purity impossible. The TRISTAN project is an attempt to discover sterile neutrinos with masses in the order of keV. In contrast to eV-scale sterile neutrinos that are motivated by several anomalies observed in terrestrial experiments, the existence of sterile neutrinos with masses in the keV range could resolve cosmological and astrophysical issues, as they are dark matter candidates. The TRISTAN project is an extension of the KATRIN experiment to search for the signature of keV-scale sterile neutrinos in the tritium β-spectrum. KATRIN itself is attempting to determine the effective neutrino mass by measuring the end point of the tritium spectrum at low counting rates. The KATRIN setup will be modified after the neutrino mass measurements are finished to conduct a differential and integral measurement of the entire tritium spectrum. This project is called TRISTAN. The current detector will be replaced by a novel 3500-pixel silicon drift detector system that has an outstanding energy resolution of a few hundred eV and can handle rates up to 10⁸ counts per second as they occur when the entire spectrum is scanned. Prototype detectors were successfully tested and first tritium data was taken at the Troitsk ν-mass spectrometer to study systematic effects and develop analysis methods. A successful fit of the differential tritium spectrum proved the feasibility of this approach. TRISTAN itself is still at an early stage, but the detector development and systematic studies are well on track and delivered so far encouraging results. The sterile neutrino search is scheduled after the KATRIN neutrino mass program is finished in ~2024.

Page generated in 0.0671 seconds