Spelling suggestions: "subject:"[een] COMFORT"" "subject:"[enn] COMFORT""
151 |
Conforto térmico em edificações /Oliveira, Lidiane Alves de. January 2003 (has links)
Orientador: Luiz Roberto Carrocci / Banca: Felipe Rinaldo Queiroz de Aquino / Banca: Luiz Octávio Mattos dos Reis / Resumo: Este trabalho analisa edifícios que, devido a sua arquitetura moderna, utilizam grande superfície de vidro nas fachadas apresentando, na maior parte das vezes, problemas de conforto térmico. Como objeto deste estudo decidiu-se por um prédio da UNESP, campus de Guaratinguetá. A análise realizada foi baseada no estudo da insolação (diagrama solar), em medidas locais de temperatura, umidade e no levantamento da carga térmica, objetivando avaliar as condições do edifício e propor soluções visando um melhor conforto térmico com a otimização do consumo de energia elétrica. / Abstract: This work analyzes buildings that, due to their modern architecture, use a great glass surface in the facades presenting, most of the time, problems of thermal comfort. As object of this study we chose a building of UNESP, campus of Guaratingueta. The accomplished analysis was based on the study of the heatstroke (solar diagram), in measuring temperature places, humidity and in the rising of the thermal load, aiming at evaluating the conditions of the building and to propose solutions seeking a better thermal comfort with the optimization of the consumption of electric energy. / Mestre
|
152 |
Getting Older and Getting Colder -The Impacts of Temperature on Health and ComfortJanuary 2013 (has links)
abstract: Research has demonstrated that temperature and relative humidity substantially influence overall perceptions of indoor air quality (Fang, Clausen, & Fanger, 1998). This finding places temperature quality as a high priority, especially for vulnerable adults over 60. Temperature extremes and fluctuation, as well as the perception of those conditions, affect physical performance, thermal comfort and health of older adults (Chatonnet & Cabanac, 1965, pp. 185-6; Fumiharu, Watanabe, Park, Shephard, & Aoyagi, 2005; Heijs & Stringer, 1988). The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) and the International Organization for Standardization (ISO) have developed thermal-comfort standards for working-age, healthy individuals. None of these standards address the physiological and psychological needs of older adults (ASHRAE Standard 55, 2010; ISO-7730, 2005). This dissertation investigates the impacts of thermal conditions on self-reported health and perceived comfort for older adults, hypothesizing that warmer and more-table indoor thermal conditions will increase the health and perceived comfort of these adults. To this end, a new set of thermal comfort metrics was designed and tested to address the thermal preferences of older adults. The SENIOR COMFORT Metrics 2013 outlined new thresholds for optimal indoor high and low temperatures and set limits on thermal variability over time based on the ASHRAE-55 2010 model. This study was conducted at Sunnyslope Manor, a multi-unit, public-housing complex in the North Phoenix. Nearly 60% (76 of 118) of the residents (aged 62-82) were interviewed using a 110-question, self-reporting survey in 73 apartment units. A total of 40 questions and 20 sub-questions addressing perceptions of comfort, pain, sleep patterns, injuries, and mood were extracted from this larger health condition survey to assess health and thermal comfort. Indoor environmental thermal measurements included temperature in three locations: kitchen, living area, and bedroom and data were recorded every 15 minutes over 5 full days and 448 points. Study results start to indicate that older adults for Sunnyslope Manor preferred temperatures between 76 and 82.5 degrees Fahrenheit and that lower temperatures as outlined by ASHRAE-55 2010 increases the rate of injuries and mood changes in older adults among other findings. / Dissertation/Thesis / Ph.D. Architecture 2013
|
153 |
The Effects of Facility Animals in the Courtroom on Juror Decision-MakingJanuary 2013 (has links)
abstract: Courthouse dogs (sometimes referred to as facility animals) are expertly trained canines which may be used to assist individuals with psychological, emotional, or physical difficulties in a myriad of courtroom situations. While these animals are increasingly used to assist young witness to court, the jury is still out on whether or not they are prejudicial to the defendant. No known research exists in this area, although research is necessary to determine the possibly prejudicial nature of these animals. Using a mock trial paradigm involving a child sexual abuse case, the current study employed a 2 (Witness type: victim vs. bystander) x 3 (Innovation type: courthouse dog vs. teddy bear vs. none) fully-crossed factorial design. It was hypothesized that witness type and innovation type would interact to differentially impact jurors' judgments about the trial, defendant, and child witness. In addition, it was posited that emotions, such as anger and disgust, would also affect judgments and decision-making. Results indicate that courthouse dogs and comfort toys did impact jurors' decision making in some ways. In addition, emotions and witness credibility predicted sentencing, verdict, and other trial judgments. / Dissertation/Thesis / M.S. Psychology 2013
|
154 |
Dynamic HVAC Operations Based on Occupancy Patterns With Real-Time Vision- Based SystemLu, Siliang 01 May 2017 (has links)
An integrated heating, ventilation and air-conditioning (HVAC) system is one of the most important components to determining the energy consumption of the entire building. For commercial buildings, particularly office buildings and schools, the heating and cooling loads are largely dependent on the occupant behavioral patterns such as occupancy rates and their activities. Therefore, if HVAC systems can respond to dynamic occupancy profiles, there is a large potential to reduce energy consumption. However, currently, most of existing HVAC systems operate without the ability to adjust supply air rate accordingly in response to the dynamic profiles of occupants. Due to this inefficiency, much of the HVAC energy use is wasted, particularly when the conditioned spaces are unoccupied or under-occupied (less occupants than the intended design). The solution to this inefficiency is to control HVAC system based on dynamic occupant profiles. Motivated by this, the research provides a real-time vision-based occupant pattern recognition system for occupancy counting as well as activity level classification. The proposed vision-based system is integrated into the existing HVAC simulation model of a U.S. office building to investigate the level of energy savings as well as thermal comfort improvement compared to traditional existing HVAC control system. The research is divided into two parts. The first part is to use an open source library based on neural network for real-time occupant counting and background subtraction method for activity level classification with a common static RGB camera. The second part utilizes a DOE reference office building model with customized dynamic occupancy schedule, including the number of occupant schedule, activity schedule and clothing insulation schedule to identify the potential energy savings compared with conventional HVAC control system. The research results revealed that vision-based systems can detect occupants and classify activity level in real time with accuracy around 90% when there are not many occlusions. Additionally, the dynamic occupant schedules indeed can bring about energy savings. Details of vision-based system, methodology, simulation configurations and results will be presented in the paper as well as potential opportunities for use throughout multiple types of commercial buildings, specifically focused on office and educational institutes.
|
155 |
Contribuição a melhora das condições ambientais de trabalho através do aprimoramento da iluminação em galpões e pátios cobertos na indústria mineral. / Contribution of environmental work conditions through improvement in lighting in closed stores and sheds in Mineral Industry.Vivien Jaglbauer 09 August 2007 (has links)
A questão ambiental e de higiene no trabalho é cada vez mais reconhecida e cobrada pela sociedade civil e pelos órgãos do governo em todas as suas instâncias. Alguns dos pátios de estocagem de minérios, que hoje estão a céu aberto, poderão precisar no futuro serem fechados para atender às normas ambientais cada vez mais rígidas, cobradas pela sociedade através dos órgãos ambientais de controle, que almejam que pátios de armazenamento tenham estanqueidade similar aos silos ou que haja um sistema de contenção de poeira e material particulado eficiente. Uma das saídas viáveis para esta questão é a estocagem do minério em galpões confinados, que demandam um custo de implantação mais elevado mas, que por outro lado, têm um baixo custo operacional. Nos pátios que possuírem fechamento, a iluminação passa a ser uma questão primordial, uma vez que proverá condições de funcionamento à produção, principalmente em caso de trabalho ininterrupto durante 24h. Desta forma, passam a ser consideradas, não somente as questões de segurança, como também de uma iluminação que estimule a produtividade através de um nível maior de iluminância, maior contraste, menor ofuscamento e seja confortável para as tarefas que serão realizadas no ambiente. Em áreas nas quais o material particulado é altamente combustível, tais como pátios de carvão mineral, uma iluminação adequada e segura é questão fundamental, pois se mal projetada, pode ser ignitora de incêndios, explosões e trágicos desastres acometendo trabalhadores e o ambiente de trabalho. Este trabalho é composto por uma extensiva revisão bibliográfica. A primeira parte apresenta os conceitos de iluminação; a segunda trata da higiene e segurança no trabalho, com ênfase no agente físico iluminação. A terceira parte comenta as normas nacionais e internacionais relacionadas à iluminação e analisa às suas solicitações. A quarta parte versa sobre áreas classificadas e atmosferas explosivas, procurando discriminar em linhas simples o que são áreas classificadas, quais os critérios envolvidos, os riscos de ignição de poeiras mais comuns e normas relacionadas a estas áreas. Na quinta parte comenta-se sobre a iluminação de galpões em áreas industriais, relacionando os critérios a serem utilizados para um projeto adequado. Na sexta parte o trabalho cita equipamentos de iluminação, lâmpadas e luminárias com aplicação industrial disponíveis no mercado. Por fim, apresenta-se de um estudo de caso realizado em uma empresa do interior de São Paulo que possui pátios para estocagem de carvão em pó, analisando-se os resultados através de dados obtidos no local e da medição dos níveis de iluminância, efetuada em horários alternados. Tais dados foram comparados às normas e recomendações de boas práticas para concluir sobre a adequação da iluminação do galpão e alternativas para solução dos problemas encontrados foram propostas. A conclusão a que se chega é que é possível contribuir para uma melhora significativa nas instalações que provêm iluminação em galpões de minérios, padronizando-as, fazendo uma manutenção adequada, substituindo equipamentos obsoletos e observando-se as normas, visando o aumento de produtividade, segurança e conforto dos trabalhadores. Estas ações implicam ainda em economia e um menor consumo de energia, cooperando com a sustentabilidade ambiental e atendendo a requisitos da família das normas NBR ISSO 14.000. / Environmental questions, occupational health and safety management are each time, more recognized and required by civil society and public agencies in all levels. Some of the ore stores that are opened today will need in the future to be closed to comply with stronger environmental regulations, required by society through controlling environmental agencies. Those agencies require the stores to be air tight or to have an efficient system of dust and particulate airbone. One feasible possibility for this question is the storage of the ore in closed sheds, which demand a higher cost of implementation, but on the other hand, it has a low cost of operation. In closed stores, the lighting is very important, since it provides necessary conditions for the workers productivity, particularly in the case of a continuous twenty four hour working day. Also, in addition to safety management, there are questions which should be considered, namely, an adjusted illumination that stimulates productivity, throughout higher illuminance, higher contrast, less glare and at the same time is comfortable for the tasks that will be carried through that environment. In environments in which the particulate material is highly combustible, such as coal stores, an adequate and safety illumination is an elementary question and if badly designed, can cause fires, explosions and tragic disasters that can injure people and destroy the working area. This work was composed by reference to an extensive bibliographical revision. The first part is a review of lighting concepts; the second refers to health and safety matters, security in the work place and also reference to the lighting. The third part highlights the national and international rules for lighting and analyzes it\'s requests. The fourth part deal with hazardous areas and explosive atmospheres, and explains in simple terms what are classified areas, which are the criteria involved, the risks of common different types of dusts and related regulations. The fifth part explains about lighting of industrial stores, with related criteria used in an adequate lighting design standard. In the sixth part it outlines the selection of lighting fixtures, light bulbs and lighting ancillaries used for industrial applications available in the market. A case in a company in the state of São Paulo, that possesses storage facilities of coal dust was carried out. The results were analyzed through data collected throughout the store and the measurement of the illumination realized at different times of the day. Such data was compared to rules, regulations and best practices in order to decide on lighting adequacy of the store and alternatives to solve the encountered problems were proposed. The conclusion is that it is possible to contribute to a significant improvement in the installations that provide illumination in the ore stores by, standardizing them, providing adequate maintenance, substituting obsolete equipment and observing rules and regulations. These measures increases the productivity, security and comfort of the workers. This action also results in cost savings, less energy consumption and ensures cooperation with environmental sustainability and complies with the requirements of NBR ISO 14.000 series.
|
156 |
Avaliação de sistemas de ventilação mecanizada por pressão positiva e negativa utilizados na avicultura de corte / Evaluation of positive and negative pressure ventilaation systems used in broiler productionLima, Karla Andrea Oliveira de 01 October 2011 (has links)
Orientador: Daniella Jorge de Moura / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-17T14:08:00Z (GMT). No. of bitstreams: 1
Lima_KarlaAndreaOliveirade_D.pdf: 5594209 bytes, checksum: 2fd1cc47487130c9ee71f42506d49d72 (MD5)
Previous issue date: 2011 / Resumo: A produção de gases no interior de galpões e suas emissões estão intimamente ligados ao microclima estabelecido no galpão pela sua temperatura, umidade e velocidade do ar. Sendo assim, o ambiente gerado no galpão, é por sua vez influenciado pela tipologia construtiva dos galpões e pelo sistema de ventilação. Este trabalho teve por objetivo geral avaliar os ambientes aéreo e térmico de galpões visando caracterizar as condições de criação de frango de corte, com base na qualidade da cama e do ar, gerados em galpões com ventilação mecânica positiva e negativa. Este projeto foi realizado em três granjas localizadas no estado de São Paulo pertencentes a duas integradoras distintas, onde oito aviários, sendo 4 do tipo pressão positiva e 4 do tipo do tipo pressão negativa, chamados de Blue house e Dark house. Foram avaliados Nestes galpões foi realizado o monitoramento das variáveis climáticas, a performance dos sistemas de ventilação utilizados, os níveis de concentração e emissão da amônia e dióxido de carbono, as condições da cama, seu pH, umidade, temperatura e condição microbiológica e serão correlacionadas a qualidade da cama gerada com a porcentagem de problemas locomotores e mortalidade dos lotes criados em galpões com ventilação mecânica positiva e negativa, em lotes com cama nova e reutilizada. Os resultados mostraram a influência dos galpões de pressão negativa na taxa de emissão de gases, CO2 e NH3 devido às suas maiores taxas de ventilação com valores que variaram de 0,25 - 0,51 gNH3/ave/dia e 387 a 907 KgCO2/galpão/dia. De acordo com o tipo de cama, se nova ou reutilizada os valores de emissão foram mais baixos para os galpões com cama nova, mesmo quando comparado os sistemas dentre si, p-valor <0,05. Os sistemas de ventilação negativa apresentaram maior consumo energético caracterizado pela potência dos seus exaustores e pelo manejo da ventilação constantemente usada durante todo o ciclo de criação. Os galpões não apresentaram diferenças estatisticamente significativas entre os seus dados zootécnicos o que caracterizou que o manejo adotado pelas integradoras foi satisfatório à produção. Através desta avaliação foi possível observar a distinção entre os sistemas de ventilação positiva e negativa quanto à emissão de gases, ao consumo energético e a sua produtividade e a viabilidade do sistema de pressão negativa na produção de frangos de corte. / Abstract: Gases production and its emission in broilers housing are related to the microclimate established in terms of temperature, humidity and air speed inside the housing. So, the environment generated in the housing is influenced by the constructive characteristics of the barn and by the adopted ventilation system. This work had as general objective to evaluate aerial and thermal environments of broiler housings aiming to characterize the conditions of broiler production, looking for the litter and air quality generated in barns with positive and negative ventilation systems. This project was carried out in three farms located in São Paulo State, under two different integrator companies responsible for the flocks management. In the total eight broiler houses were evaluated being four houses named positive pressure and four named negative pressure. Both systems were mechanically ventilated systems. Climatic variables, the performance of ventilation systems, gases concentration levels and emissions were monitored in these houses. Further research was carried out about the litter condition, its pH, humidity, temperature and its correlation between litter quality and mortality and lameness incidence on the flocks The results showed the influence of the negative pressure systems on the, CO2 and NH3 emission rate due to their higher ventilation rates with values ranging from 0.25 to 0.51 and from 387 to 907 gNH3/bird/day and KgCO2 /house /day. The emissions rates were lower according to the type of litter, new or built-up even when compared among the systems themselves, p-value <0.05. Negative pressure systems had higher energy consumption characterized by the power of exhausters motor and ventilation management that was constantly running throughout the growing period. The broiler houses showed no statistically significant differences between their data production that means that management adopted by integrator companies was satisfactory. Through this assessment it was possible to observe the distinction between the positive and negative ventilation systems on the emissions rates, energy consumption and its productivity where it was also noticed the viability of the negative pressure system in the broilers production. / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
|
157 |
O significado da tradição na autoconstrução de moradiasWatrin, Vanessa da Rosa 21 February 2003 (has links)
Orientador: Doris C. C. K. Kowaltowski / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-05T13:51:41Z (GMT). No. of bitstreams: 1
Watrin_VanessadaRosa_M.pdf: 5056574 bytes, checksum: 9c3e492b4f0de5a03e722ddb3715f321 (MD5)
Previous issue date: 2003 / Resumo: A presente pesquisa se concentra na área da habitação de interesse social e busca trazer contribuições para o conforto térmico de moradias autoconstruídas, a partir da experiência da arquitetura tradicional. O objetivo principal é investigar o que é considerado como tradição e qual é a noção de conforto térmico, em relação à moradia, que os autoconstrutores da cidade de Campinas-SP possuem. A arquitetura autoconstruída é uma forma de moradia muito presente na população de baixa renda e já chega a ser o modo predominante de se morar no Brasil, por isso a qualidade de vida que estas moradias proporcionam à população é de extrema importância. Como as condições climáticas locais não são rigorosas, não encontramos nas casas autoconstruídas uma presença sistemática de elementos arquitetônicos tradicionais positivos, demonstrando que a população de autoconstrutores não tem uma preocupação com, ou não prioriza as questões climáticas. Contudo, é de nosso interesse que o conhecimento acumulado pela arquitetura tradicional seja transmitido para os autoconstrutores, já que a arquitetura vernacular tradicional é internacionalmente conhecida por ter uma consciência profunda do clima e por garantir níveis satisfatórios de qualidade ambiental às construções / Abstract: The current research concentrates on low-income housing and tries to contribute knowledge on self-built houses and their thermal comfort, based on traditional architecture of the region. The main goal was to determine what self-builders consider to be tradition; how they relate this concept to house building and whether traditional methods contribute toward comfort. The self-built house can be said to be the most common solution to the housing deficit of lowincome families in Brazil. Results of the study showed that no systematic presence of positive traditional architectural elements was found in self-built houses. The local non-rigorous climate conditions also do not stimulate specific building techniques and designs. The simple self-built house of today was identified as the traditional house, demonstrating a lack of knowledge related to the historical development of the house in Brazil. The study found, on the whole, that good building practice is not transmitted from generation to generation, simple traditional construction techniques persist. For traditional positive elements to regain their place in house design consciousness must be stimulated amongst the self-builder population through technical aid and examples. This quest is based on the accumulated knowledge on traditional architecture and the well-known environmental comfort qualities of vernacular architecture worldwide / Mestrado / Edificações / Mestre em Engenharia Civil
|
158 |
Avaliação do conforto termico em industrias de calçadosVoltani, Eder Ricardo 13 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T19:58:30Z (GMT). No. of bitstreams: 1
Voltani_EderRicardo_M.pdf: 1781580 bytes, checksum: 4e5a97494a32fe55f6e8a82e215edab3 (MD5)
Previous issue date: 2009 / Resumo: Os métodos Predicted Mean Vote ¿ PMV e Predicted Percentage Dissatisfied ¿ PPD foram desenvolvidos por Ole Fanger e significaram um expressivo avanço nos estudos sobre avaliação de conforto térmico. No ano de 1984 estes métodos foram adotados pela International Organization for Standardization ¿ ISO como base da norma 7730. No entanto, diversas pesquisas foram realizadas com o objetivo de encontrar a sensação térmica para pessoas expostas a diferentes combinações das variáveis ambientais e pessoais, pois existiam alguns questionamentos a respeito da aplicabilidade desta norma em campo e para diferentes regiões climáticas. Dessa forma, esta pesquisa tem por objetivo obter informações para a análise da aplicabilidade do modelo PMV/PPD da norma ISO 7730 (2005) como meio de avaliação do conforto térmico em ambientes de trabalhos industriais, onde a atividade seja leve ou moderada. Esta pesquisa foi desenvolvida nas indústrias de calçado feminino da região de Jaú, SP. Quanto à metodologia, foram obtidos os dados da temperatura do ar, umidade relativa, velocidade relativa do ar e temperatura radiante média, conforme recomendações da norma ISO 7726 (1998). O isolamento térmico das vestimentas e as taxas de metabolismo foram estimados por meio de valores referenciais de tabelas das normas ISO 9920 (1995) e ISO 8996 (1990), respectivamente. Para calcular os valores de PMV e PPD foi utilizado o Software Conforto 2.03. Os votos de Sensação e Preferência Térmica foram obtidos através de um questionário aplicado junto à população pesquisada. Com o desenvolvimento de análises de Regressão Simples e Probit, foi possível encontrar a zona de conforto térmico da população pesquisada, comparar a correlação, temperatura de neutralidade e a porcentagem de pessoas insatisfeitas entre os votos obtidos dos trabalhadores com os resultados dos cálculos do PMV/ PPD. Através de simulações foi possível identificar que a interpretação das atividades desenvolvidas, o tipo de questionário aplicado e o controle das respostas da população provocam desvios de 8%, 12% e 7,6%, respectivamente, nos resultados da correlação entre os votos das sensações térmicas e os resultados do calculo de PMV. Por meio da análise Probit dos votos de sensação e preferência térmica da população com 1,4 met foi possível obter a temperatura de neutralidade de 23,35 °C, com 84,5% da população em conforto térmico e 15,5% em desconforto térmico. Conforme cálculo de PMV, para as mesmas condições, a temperatura de neutralidade é 22,4 °C / Abstract: The methods Predicted Mean Vote ¿ PMV and Predicted Percentage Dissatisfied ¿ PPD were developed by Ole Fanger and represent a meaningful advance in studies about assessment of thermal comfort. In 1984 these methods were adopted by the International Organization for Standardization -ISO as the basis for standard 7730. However, several researches were made with the purpose of finding the thermal sensation of people exposed to different combinations of environmental and personal variables because of some questionings regarding its applicability in field and in different climatic regions. Therefore, the aim of this work has been to collect information for the analysis of the applicability of the PMV/PPD methods in the standard ISO 7730 (2005), as a means to evaluate thermal comfort in industrial work environment with light sedentary or moderate activity. The research was carried out in female shoe-making industries in the region of Jaú, State of São Paulo. The adopted methodology was defined as follows: data collecting of air temperature, relative humidity, the relative air velocity, and mean radiant temperature, according to the recommendations of ISO 7726 (1998). The clothing insulation and the metabolic rates were estimated by means of the referential value tables in ISO 9920 (1995) and ISO 8996 (1990), respectively. The Comfort Software 2.03 was used to calculate the PMV and the PPD values. Questionnaires were applied among the workers with questions involving the personnel vote for the Thermal Sensation and Preferences. By running the analyses of Simple Regression and Probit, is was possible to compare the correlation between the temperature of neutrality and the percentage of dissatisfied people amongst the personnel votes to the outcomes of the PMV/PPD figures. Through simulations it was possible to identify that the interpretation of activities, the type of questionnaire applied and the control of the responses of the population caused deviations of 8%, 12% and 7.6%, respectively, in the results of the correlation between the votes for thermal sensations and the results of the calculation of PMV. The analyses Probit with the votes of sensation and thermal preference of people with activity 1.4 met the temperature of neutrality was 23.35 °C, with 84.5% of population in comfort and 15.5% in thermal discomfort. As for the calculation of PMV, in the same conditions, the temperature of neutrality is 22.4 °C / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil
|
159 |
Desempenho termico de vidros utilizados na construção civil : estudo em celulas-teste / Thermal performace of glasses in building construction: study in test-cellsCastro, Adriana Petito de Almeida Silva 26 June 2006 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-08T09:29:44Z (GMT). No. of bitstreams: 1
Castro_AdrianaPetitodeAlmeidaSilva_D.pdf: 2534532 bytes, checksum: 4ea70ab9e519a13a5ddf61c29646f7b7 (MD5)
Previous issue date: 2006 / Resumo: O desempenho térmico de uma edificação depende de fatores como implantação, orientação, materiais e componentes construtivos, que devem ser adequadamente definidos para diferentes condições climáticas. O edifício atua como mecanismo de controle das variáveis do clima, através de sua envoltória (paredes, piso, cobertura e aberturas) e dos elementos do entorno, e deve ser projetado de modo a proporcionar conforto e eficiência energética. Entre os componentes da construção, os vidros funcionam como um dos elementos de maior potencialidade de aquecimento interno. Devido à sua transparência à radiação solar, possibilitam facilmente o ingresso de grande parte dessa energia no ambiente. No presente rabalho estudou-se o comportamento de superfícies transparentes em fachadas, em situação real, através de medições em seis células-teste, de dimensões 2,00 x 2,50m. Analisou-se in loco o comportamento térmico de vidros, comercialmente disponíveis no mercado, cuja caracterização, do ponto de vista da transmissão espectral, já era conhecida através de técnica espectrofotométrica. Foram selecionados 14 tipos de vidros: cinco planos, quatro refletivos pirolíticos, três refletivos metalizados a vácuo e dois laminados, os quais foram instalados em aberturas de 1,00 X
1,20m nas células-teste, localizadas em fachadas com orientação norte e oeste. A análise foi realizada separadamente para as duas orientações. Avaliou-se o desempenho térmico de cada vidro, tendo o incolor, de espessura 4mm, como referência. A metodologia utilizada consistiu na aquisição de dados mensuráveis de parâmetros ambientais: temperaturas superficiais internas dos vidros, temperaturas de bulbo seco no ambiente interno e temperaturas do ar externo. O fator de ganho solar foi calculado a partir dos resultados de absortância dos diferentes materiais, obtidos por análise espectrofotométrica, e diferenças entre as temperaturas interna e externa. Os resultados mostram o alto ganho de calor através dos vidros planos, sendo o incolor o de pior desempenho térmico, com maior ganho, seguido pelo bronze, cinza e verde. Os vidros refletivos metalizados a vácuo apresentam o melhor desempenho térmico, dentre os materiais analisados, quando se tem como objetivo atenuar o ganho de calor e projetar edificações com menor consumo energético para refrigeração / Abstract: Thermal performance of buildings depends on several factors, such as implantation, orientation, materials and building components, which should be appropriately defined for different climate conditions. The building acts as a controller of the climatic variables, through the building envelope (walls, floor, roof and openings) and the nearby elements. Building design must provide indoor comfort and energy efficiency. Glazing easily allows the penetration of solar radiation into buildings, due to its transparency to solar radiation. So glasses must be carefully considered in building design, having in mind their potential for internal heating. In this work studies about the behavior of transparent façades, in real conditions, were carried out through measurements in six test-cells with dimensions 2,00 x 2,50m. Fourteen types of glasses were selected: five float glasses, four reflective glasses produced by pyrolitic process, three reflective ones obtained by vacuum metal deposition and two laminated glasses. Their spectral behavior was known from previous spectrophotometric studies. The glasses were installed in 1,00 X 1,20m openings in two façades facing north and west, separately. The colorless 4mm float glass was taken as reference. Internal surface temperatures of glasses, internal dry bulb temperatures and outdoor temperatures were collected. Solar gain factor was calculated on the basis of absortance values, obtained from spectrophotometrical nalysis, and temperature differences inside and outside the cells. Results show a high heat gain through float glasses, with the worst thermal behavior for the colorless one, followed by bronze, gray and green. Furthermore, reflective glasses obtained by vacuum metal deposition present the best thermal performance for the purpose of heat gain attenuation and to
design buildings with the least energy consumption for cooling / Doutorado / Edificações / Doutor em Engenharia Civil
|
160 |
Desempenho termico de edificações : um programa de simulação computacional utilizando o metodo da admitancia / Thermal performance of buildings : application of the admittance procedure in a simulation computer programPinto, Luciana da Rosa 22 February 2002 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-10T20:24:27Z (GMT). No. of bitstreams: 1
Pinto_LucianadaRosa_M.pdf: 3251047 bytes, checksum: dc3ceed89794d388aeedbb2eb8854fc5 (MD5)
Previous issue date: 2002 / Resumo: O conhecimento do comportamento térmico de uma edificação é necessário, não só para que seja possível planejar e obter ambientes confortáveis termicamente, como para minimizar o consumo de energia, principalmente para refrigeração, em climas quentes como o do Brasil. Na fase de projeto, ferramentas de simulação computacional são de grande valia para esse fim. Porém as ferramentas disponíveis em geral são de difícil utilização, necessitando de um treinamento especial para seu uso. O objetivo desse trabalho foi o de produzir uma ferramenta de simulação de desempenho térmico de edificações, de fácil utilização pelos projetistas. São analisados os conceitos envolvidos nas trocas térmicas entre a edificação e o ambiente, buscando um método simples para a avaliação de seu desempenho térmico. Entre vários modelos analisados, adotou-se o método da admitância, cuja principal vantagem é que a previsão das temperaturas e fluxos de energia aceitáveis é obtida através de um procedimento simples, onde os três parâmetros envolvidos: admitância, fator decremento e fator de superfície dão uma indicação qualitativa do provável comportamento das construções. Com base neste método foi desenvolvida uma ferramenta de simulação computacional que permite ao projetista, ainda na fase de concepção, utilizar se de uma planilha eletrônica, para simular e comparar as várias alternativas de projeto e avaliar o correspondente desempenho térmico da edificação em estudo / Abstract: It is well known the importance of a good knowledge of the thermal performa nce of a building, allowing the planning and design of thermally comfortable environments, as well as energy efficient buildings. Architectural design methods in their early development phases define building's internal environment, and computer simulation can be of great value for this purpose. The aim of this work was to develop a design tool for the simulation of thermal performance of buildings, which could be user friendly and presenting trustful results. The work analyzes the concepts involved in the thermal exchanges between the building and the environment, according to the admittance model. This method has as main advantage that acceptable temperature and energy determinations are given by a simple procedure, where the three involved parameters: admittance, decrement factor and surface factor provide a qualitative indication of the probable thermal behavior of the construction. Based on this method it was developed a computer simulation tool to allow the designer, still in the conception phase, to simulate and to compare the several design alternatives and to evaluate the corresponding thermal performance of the building in study / Mestrado / Edificações / Mestre em Engenharia Civil
|
Page generated in 0.0587 seconds