• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 162
  • 73
  • 42
  • 16
  • 13
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 368
  • 368
  • 72
  • 54
  • 51
  • 47
  • 44
  • 44
  • 34
  • 33
  • 31
  • 29
  • 25
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Fiber optic confocal imaging for in vivo detection and diagnosis of pre-cancerous lesions /

Smithpeter, Colin Lee. January 1997 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 1997. / Vita. Includes bibliographical references (leaves 188-199). Available also in a digital version from Dissertation Abstracts.
102

Estudo do efeito da quitosana utilizada no preparo biomecânico sobre as paredes dos canais radiculares mediante avaliação por espectroscopia e microscopia confocal a laser / The effects of chitosan on root canal walls in the diferente stages of the biomechanical preparation: a spectroscopy and laser confocal microscopy study

Vanessa Lessa Cavalcanti de Araujo 10 May 2017 (has links)
O objetivo deste estudo foi avaliar, in vitro, o efeito das soluções irrigadoras quitosana a 0,2%; hipoclorito de sódio a 1% e EDTA a 17% na superfície dentinária e na interface de união da dentina/material obturador resinoso. Sessenta fragmentos de dentina, obtidos de 10 caninos superiores humanos, com 4 mm2 de área foram distribuídos em quatro grupos (n=15) de acordo com o tratamento: G1 NaOCl + EDTA + NaOCl, G2 NaOCl + Quitosana + NaOCl, G3 Quitosana + Quitosana + Quitosana, G4 Quitosana + EDTA + Quitosana. As amostras foram imersas por 6 minutos na primeira solução irrigadora (Tempo 1), 3 minutos na segunda (Tempo 2) e 1 minuto na terceira (Tempo 3), simulando o tratamento endodôntico. Foi analisada a composição orgânica e inorgânica das amostras por meio da Espectroscopia Infravermelha por Transformada de Fourier (FTIR) após cada etapa de irrigação. Para segunda fase, 24 caninos superiores humanos, divididos em 4 grupos (n=6), tiveram suas coroas cortadas e as raízes instrumentadas mecanicamente com instrumentos K3 até o instrumento 60.04, irrigadaos com NaOCl a 1% e Quitosana a 0,2% durante o preparo e EDTA a 17% e Quitosana a 0,2% como irrigação final. As amostras foram cortados longitudinalmente para análise do número e do perímetro dos túbulos expostos nos diferentes tempos e a rugosidade da superfície antes (baseline) e após cada fase do tratamento, além da penetração do cimento endodôntico, e avaliação da interface material obturador/dentina, após a obturação (Tempo 3), por meio de microscopia confocal a laser. Os dados foram analisados pela ANOVA e pós-teste de Tukey (p<0,05). Por meio do FTIR, constatou-se que o G4 apresentou maiores valores de matéria orgânica quando comparado aos outros grupos (p<0,05), e foram observados maiores valores para o T3 quando comparado ao T0. Quanto aos valores de matéria inorgânica, o G1 apresentou valores superiores (p<0,05) aos G2 e G3. Não houve diferença quando comparado os tempos para o conteúdo inorgânico (p>0,05). O terço apical apresentou maior valores de conteúdo inorgânico quando comparado aos demais (p<0,05). Por meio do confocal, observou-se que apenas o G3 apresentou maiores valores de perímetro dos túbulos com diferença em relação ao G1,(p<0,05), que o T2 apresentou valores semelhantes ao T1 (p>0,05), e não houve diferença entre os terços radiculares. Na análise da contagem dos túbulos dentinários, observa-se que o G4 apresentou maiores valores, semelhantes ao G3 (p>0,05). O T2 apresentou os maiores valores e o T0 os menores (p<0,05), e o terço cervical apresentou maiores valores em relação aos demais (p<0,05). Na análise da rugosidade, não houve diferença entre os grupos, e nem entre os terços radiculares (p>0,05), sendo que o T0 apresentou maiores valores, com diferença em relação ao T1 e T2 (p<0,05). Na análise da interface material obturador/dentina, não houve diferença entre os grupos, e o terço apical apresentou menor extensão de tags formados (p<0,05). A Quitosana como solução irrigadora produziu efeitos favoráveis na dentina radicular sem afetar a interação do substrato com o cimento endodôntico. / The aim of this study was to evaluate, in vitro, the influence of irrigation solutions, used during instrumentation of root canals - chitosan at 0.2%; 1% sodium hypochlorite and 17% EDTA - on dentin, by means of Fourier Transform Infrared Spectroscopy (FTIR) and laser confocal microscopy. Sixty dentin fragments, obtained from 10 human canines, with 4 mm2 area were distributed in four groups (n = 15) according to the treatment: G1 NaOCl + EDTA + NaOCl, G2 NaOCl + Chitosan + NaOCl, G3 Chitosan + Chitosan + Chitosan, G4 Chitosan + EDTA + Chitosan. The samples were immersed for 6 minutes in the first irrigation solution (Time 1), 3 minutes in the second (Time 2) and 1 minute in the third (Time 3), simulating the endodontic treatment. The organic and inorganic composition of the samples were analyzed by Fourier Transform Infrared Spectroscopy (FTIR) after each irrigation step. In a second phase, 24 teeth were divided into 4 groups (n = 6), cut longitudinally to analyze the number and perimeter of the exposed tubules at different times, the surface roughness before and after each treatment phase. The penetration of the endodontic sealer, and evaluation of the dentin interface, after the obturation (Time 3), by laser confocal microscopy. Data were analyzed by ANOVA and Tukey post hoc test (p<0.05). Using FTIR, G4 presented higher values of organic content when compared to the others groups (p <0.05), and higher values were observed for T3 when compared to T0. There was no difference when comparing the times for the inorganic content (p> 0.05). The apical third had higher values of inorganic content when compared to the others (p <0.05). With the aid of the confocal analysis, it was observed that only G3 presented higher values of tubule perimeter with difference in relation to the G1, (p <0.05), that T2 presented values similar to T1 (p> 0.05), And there was no difference between the root thirds. In the analysis of the dentinal tubule count, it was observed that G4 presented higher values, similar to G3 (p> 0.05). The T2 presented the highest values and T0 the lowest (p <0.05), and the cervical third had higher values compared with the others (p <0.05). Regarding the analysis of roughness, there was no difference between the groups, nor between the root thirds (p> 0.05), and the T0 presenting higher values compared with T1 and T2 (p <0.05). In the analysis of the dentin interface, there was no difference between the groups, and the apical third had a smaller extension of the formed tags (p <0.05). Chitosan produced less chemical changes in root dentin when compared to the other solutions.
103

Analyse multi-échelle de la filtration sur microsive de particules modèles inertes et biologiques : caractérisation in situ du dépôt par microscopie confocale / In situ multiscale 3D characterization of model inert and biological particle cakes using confocal laser scanning microscopy

Ben Hassan, Ines 15 April 2014 (has links)
Durant les opérations de filtration membranaire, les industries font face à un problème majeur : le colmatage. En particulier, la formation d’un dépôt de particules sur la membrane provoque une chute de sa perméabilité et de sa sélectivité. L’étude a pour but de mieux caractériser la morphologie des dépôts de particules, en lien avec ses propriétés de transport, dans le but d’enrichir les modèles utilisés pour prédire les performances de filtration des dispositifs industriels. Des expériences de filtration de suspensions pures et mixtes de particules inertes et biologiques, sont réalisées sur des microsieves et observées in situ par microscopie confocale. Les propriétés spatiales du dépôt (arrangement des particules, épaisseur, porosité, taux de couverture de la membrane) sont déterminées par traitement d’images et corrélées aux variations de perméabilité. L’influence des paramètres tels que : la taille des particules, la géométrie de la microsieve (taille de pore, distance entre pores) et la nature des particules, est soigneusement analysée. Plusieurs mécanismes physiques sont mis en évidence : - La préfiltration de grosses particules avant la filtration des petites maintient un débit élevé.- Les particules déposées protègent les pores qui leurs sont périphériques lorsque le rapport « taille de particules / taille de pores » est élevé.-Dans les conditions expérimentales étudiées, la morphologie des dépôts de particules inertes et biologiques est identique.- Le dépôt est structuré en trois régions distinctes : une zone de germination en contact avec la membrane, une couche centrale dense, une région de capture superficielle / During the operations of filtration, the industries are facing a major problem: fouling. Indeed, the cake layer build-up on top of the membrane reduces its productivity and selectivity. The aim of this study is to characterize the particle deposit morphology at different operating conditions in order to enhance the models used to predict the filtration performances at the industrial level. Pure and mixed suspensions of inert and biological particles are filtrated with microsieves and observed in situ by Confocal Laser Scanning Microscopy (CLSM). The spatial properties of the cake (particle arrangement, thickness, porosity, microsieve coverage) are determined by image processing and correlated with the permeability reduction. The effect of the parameters such as: the particles size, the microsieve geometry (pore size, pore pitch) and the particles characteristics, is carefully analyzed. Several physical mechanisms are highlighted:- The prefiltration of large particles before the filtration of the small ones maintains a high flux.- Deposited particles protect the surrounding pores when the ratio "particles size/pores size" is high.- In the studied experimental conditions, the cake morphology of the inert and biological particles is similar.- The cake is structured in three regions: germination region in contact with the membrane, a central high particle concentration region and a superficial region, named capture region
104

Stanovení velikosti genomu jeseterů 2-D a 3-D obrazovou cytometrií. / The genome size determination in sturgeons using 2-D a 3-D image cytometry.

SRP, Jiří January 2012 (has links)
The genome size of evolutionary polyploid, neopolyploid and hybrid sturgeons is well known for its high variability. Aim of this study was 1) to specify the genome size of polyploid and neopolyploid sturgeons using an analysis of 2-D and 3-D images of specifically stained cells nuclei, 2) to evaluate the samples of populations for cytogenetic analysis needs and thereafter, 3) to compare both methods and record the data either for next research or for negative selection from the broodstock. This test has been done at the laboratory of molecular, cellular and quantitative genetics, Faculty of Fisheries and Protection of Waters USB in Vodňany using all sturgeons spawners and using samples obtained from some foreign fish farms which cooperated with the faculty. The samples included A. ruthenus, A. baerii, A. stellatus, A. gueldenstaedtii and Huso huso, intentionally bred hybrids of A. gueldenstaedtii (8n) x A. baerii (12n), A. baerii (8n) x A. ruthenus (4n), A. gueldenstaedtii (8n) x A. baerii (10n) a A. gueldenstaedtii (8n) x A. ruthenus (4n). As methods have been chosen image cytometry and confocal microscopy which use image digitalization and subsequently its computer analysis. The genome size was measured from the size of specifically stained nuclei of erythrocytes in specimens sampled. Result of this study was measuring the genome size in sturgeons under study using different methods, recording the obtained data, description of spatial conformation changes of cell nucleus with increasing ploidy level and deduction of impact to their physiology and comparing the methods between each other. The conclusion is necessity of another sturgeons genome size determination , choice of the best methods for more effective search and research of non-standard individuals and subsequently an examination of their physiological differences.
105

Efeito do laser ER:YAG e ponta diamantada na morfologia da camada híbrida obtida com um adesivo autocondicionante: resistência de união ao microcisalhamento análise por MEV e MLCF

Gonçalves, Aline de Oliveira [UNESP] 26 March 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-26Bitstream added on 2014-12-02T11:21:11Z : No. of bitstreams: 1 000738257_20160326.pdf: 483238 bytes, checksum: 55b8baebdfcf5e968a88fb759b4e6be6 (MD5) Bitstreams deleted on 2016-03-28T13:37:45Z: 000738257_20160326.pdf,. Added 1 bitstream(s) on 2016-03-28T13:38:48Z : No. of bitstreams: 1 000738257.pdf: 2384428 bytes, checksum: 2f5315a3ccb28b42496282478231b8fd (MD5) / Este estudo tem como objetivo avaliar o efeito de laser de Er: YAG (L) e ponta diamantada (B) sobre a força de resistência ao microcisalhamento (MPa) e o efeito sobre a interface adesiva de adesivos condiciona e lava (CL) – Adper Scotchbond Multiuso e autocondicionante (CS) – Adper EasyOne, ambos da 3M ESPE. Foram constituídos 4 grupos segundo instrumentos e adesivos: B_CL (controle); B_CS; L_CL e L_CS. 60 incisivos bovinos foram randomicamente divididos nos experimentos e grupos: 40 para força de resistência ao microcisalhamento (n=10) e 20 para morfologia da interface adesiva (6 para mensuração da espessura da camada hibrida (CH) e comprimento de tags (t) por MLCF (n=3); 12 para morfologia da interface adesiva por MEV (n=3) e 2 para ilustração o efeito dos instrumentos sobre dentina por MEV (n=1). Para o ensaio de microcisalhamento foram confeccionados 4 cilindros de resina composta Filtek Z350 XT – 3M ESPE (0,7 mm de diâmetro por 1 mm de altura e área de adesão de 0,38 mm2) sobre cada superfície de dentina tratada pelos instrumentos e adesivos. O ensaio de resistência de união ao microcisalhamento foi realizado em máquina de ensaio universal EMIC 2000, com célula de carga de 500 Kgf e velocidade de 0,5 mm/min. A interface adesiva foi caracterizada pela espessura da camada hibrida (CH) e comprimento de tags (t) em μm, com o software UTHSCSA Imagetool. Os valores de resistência adesiva ao microcisalhamento foram L_CL 34,10 ± 19,07 MPa, B_CL 24,26 ± 9,35 MPa, L_CN 33,18 ± 12,46 MPa, B_CN 21,24 ± 13,96 MPa. Anova two-way resultou em diferença estatisticamente significativa somente para instrumentos (p=0,047). Teste de Mann-Whitney identificou os instrumentos determinam diferenças significativas para de espessura de CH e comprimento de (t). Para adesivos estas diferenças só foram observadas para (t). Pode-se concluir que 1) Laser de Er:YAG resulta em maiores valores de... / This study aims to evaluate the effect of Er: YAG (L) and bur (B) on the strength of resistance microshear (MPa) and the effect on the interface adhesive stickers and wash conditions (CL) - Adper Scotchbond Multipurpose and self (CS) - Adper EasyOne, both from 3M ESPE. Were formed 4 groups according tools and adhesives: B_CL (control); B_CS; L_CL and L_CS. 60 bovine incisors were randomly divided into experimental and groups: 40 to force microshear resistance (n = 10) and 20 for the adhesive interface morphology (6 to measure the thickness of the hybrid layer (CH) and length of tags (t) by MLCF (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1). Microshear For testing four cylinders were fabricated composite Filtek Z350 XT - 3M ESPE (0.7 mm in diameter and 1 mm in height and area of adhesion of 0.38 mm) on each dentin surface treated by tools and adhesives. Testing of bond strength was performed in microshear FDMS universal testing machine 2000 with a load cell of 500 kgf and a speed of 0.5 mm / min. Adhesive interface was characterized by layer thickness hybrid (HC) and length of tags (t) in nm, with software UTHSCSA ImageTool. Values of bond strength to microshear L_CL were 34.10 ± 19.07, 24.26 ± 9.35 B_CL, L_CN 33.18 ± 12.46, 21.24 ± 13.96 B_CN. Anova two- way resulted in statistically significant only for instruments (p = 0.047). Mann-Whitney identified instruments to determine significant differences CH thickness and length (t). adhesives for these differences were only observed for (t). It can be concluded that 1) Laser Er: YAG results in higher bond strength to the microshear, regardless of the adhesive system (CL and CS). 2) The tags have no significant effect on bond strength to microshear. 3) The adhesive interface is affected by both instruments for cavity preparation and the type of adhesive system...
106

Efeito do laser ER:YAG e ponta diamantada na morfologia da camada híbrida obtida com um adesivo autocondicionante : resistência de união ao microcisalhamento análise por MEV e MLCF /

Gonçalves, Aline de Oliveira. January 2013 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Mirian Lacalle Turbino / Banca: Edson Alves de Campos / Resumo: Este estudo tem como objetivo avaliar o efeito de laser de Er: YAG (L) e ponta diamantada (B) sobre a força de resistência ao microcisalhamento (MPa) e o efeito sobre a interface adesiva de adesivos condiciona e lava (CL) - Adper Scotchbond Multiuso e autocondicionante (CS) - Adper EasyOne, ambos da 3M ESPE. Foram constituídos 4 grupos segundo instrumentos e adesivos: B_CL (controle); B_CS; L_CL e L_CS. 60 incisivos bovinos foram randomicamente divididos nos experimentos e grupos: 40 para força de resistência ao microcisalhamento (n=10) e 20 para morfologia da interface adesiva (6 para mensuração da espessura da camada hibrida (CH) e comprimento de tags (t) por MLCF (n=3); 12 para morfologia da interface adesiva por MEV (n=3) e 2 para ilustração o efeito dos instrumentos sobre dentina por MEV (n=1). Para o ensaio de microcisalhamento foram confeccionados 4 cilindros de resina composta Filtek Z350 XT - 3M ESPE (0,7 mm de diâmetro por 1 mm de altura e área de adesão de 0,38 mm2) sobre cada superfície de dentina tratada pelos instrumentos e adesivos. O ensaio de resistência de união ao microcisalhamento foi realizado em máquina de ensaio universal EMIC 2000, com célula de carga de 500 Kgf e velocidade de 0,5 mm/min. A interface adesiva foi caracterizada pela espessura da camada hibrida (CH) e comprimento de tags (t) em μm, com o software UTHSCSA Imagetool. Os valores de resistência adesiva ao microcisalhamento foram L_CL 34,10 ± 19,07 MPa, B_CL 24,26 ± 9,35 MPa, L_CN 33,18 ± 12,46 MPa, B_CN 21,24 ± 13,96 MPa. Anova two-way resultou em diferença estatisticamente significativa somente para instrumentos (p=0,047). Teste de Mann-Whitney identificou os instrumentos determinam diferenças significativas para de espessura de CH e comprimento de (t). Para adesivos estas diferenças só foram observadas para (t). Pode-se concluir que 1) Laser de Er:YAG resulta em maiores valores de... / Abstract: This study aims to evaluate the effect of Er: YAG (L) and bur (B) on the strength of resistance microshear (MPa) and the effect on the interface adhesive stickers and wash conditions (CL) - Adper Scotchbond Multipurpose and self (CS) - Adper EasyOne, both from 3M ESPE. Were formed 4 groups according tools and adhesives: B_CL (control); B_CS; L_CL and L_CS. 60 bovine incisors were randomly divided into experimental and groups: 40 to force microshear resistance (n = 10) and 20 for the adhesive interface morphology (6 to measure the thickness of the hybrid layer (CH) and length of tags (t) by MLCF (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1). Microshear For testing four cylinders were fabricated composite Filtek Z350 XT - 3M ESPE (0.7 mm in diameter and 1 mm in height and area of adhesion of 0.38 mm) on each dentin surface treated by tools and adhesives. Testing of bond strength was performed in microshear FDMS universal testing machine 2000 with a load cell of 500 kgf and a speed of 0.5 mm / min. Adhesive interface was characterized by layer thickness hybrid (HC) and length of tags (t) in nm, with software UTHSCSA ImageTool. Values of bond strength to microshear L_CL were 34.10 ± 19.07, 24.26 ± 9.35 B_CL, L_CN 33.18 ± 12.46, 21.24 ± 13.96 B_CN. Anova two- way resulted in statistically significant only for instruments (p = 0.047). Mann-Whitney identified instruments to determine significant differences CH thickness and length (t). adhesives for these differences were only observed for (t). It can be concluded that 1) Laser Er: YAG results in higher bond strength to the microshear, regardless of the adhesive system (CL and CS). 2) The tags have no significant effect on bond strength to microshear. 3) The adhesive interface is affected by both instruments for cavity preparation and the type of adhesive system... / Mestre
107

Espectroscopia de correlação de fluorescência aplicada em estudos de sistemas moleculares, biológicos e celulares / Fluorescence correlation spectroscopy applied in studies of molecular, biological and cellular systems

Fernando Massayuki Tsutae 24 May 2016 (has links)
A espectroscopia de correlação de fluorescência (FCS) é uma das diferentes técnicas de análise por imagens de alta resolução espacial e temporal de biomoléculas em concentrações extremamente baixas. Ela se tornou uma técnica extremamente poderosa e sensível em áreas como bioquímica e biofísica. Como uma técnica bem estabelecida, ela é utilizada para medir concentrações locais de biomoléculas, através da marcação com moléculas fluorescentes. Coeficientes de difusão e constantes cinéticas também podem ser medidos através de FCS assim como detecção de molécula única. Ela também pode dar informação precisa sobre interações de antígeno-anticorpo, ácidos nucleicos e proteínas. Através de uma combinação de marcadores de alto rendimento quântico, fontes de luz estável (lasers), detecção ultrassensível e microscopia confocal, é possível realizar medidas de FCS em volumes de fentolitros (fL) e em concentrações de nanomolar (nM) em soluções aquosas ou em células vivas. Em contraste com outras técnicas de fluorescência, a sensibilidade da FCS aumenta com a diminuição da concentração do fluoróforo marcador, porque o parâmetro de interesse não é a intensidade de emissão de fluorescência, mas sim as flutuações espontâneas da fluorescência. Durante o tempo em que a partícula ou molécula atravessa o volume de medida pode ocorrer mudanças conformacionais e reações químicas e fotofísicas que alteram as características de emissão do fluoróforo e causam flutuações no sinal detectado. Estas flutuações são então monitoradas e transformadas em uma curva de autocorrelação, por intermédio de um software comercial que emprega um modelo físico apropriado para FCS. Em nosso estudo, utilizamos um marcador comercial (ALEXA 488&reg;) para marcar proteínas. Primeiramente utilizamos a técnica de FCS para medir concentrações extremamente baixas de marcadores fluorescentes. Também realizamos um experimento testando a influência da viscosidade do meio na difusão livre do fluoróforo, assim como as melhores condições em que temos um melhor sinal de FCS. Por fim, estudamos a difusão de proteínas marcadas (PUC II e IV) em meio aquoso (PBS) e no interior de células. / Fluorescence correlation spectroscopy (FCS) is one of the many different modes of high-resolution spatial and temporal analysis of extremely low concentrated biomolecules. It has become a powerful and sensitive tool in fields like biochemistry and biophysics. As a well established technique, it is used to measure local concentrations of fluorescently labeled biomolecules, diffusion coefficients, kinetic constants and single molecule studies. Through a combination of high quantum yield fluorescent dyes, stable light sources (lasers), ultrasensitive detection and confocal microscopy is possible to perform FCS measurements in femtoliters volumes and nanomolar concentrations in aquous solution or in live cells. Unlike with other fluorescence technics, its sensibility increases with the decrease of dye concentrarion, because the main factor is not the emission intensity itself. Instead this, spontaneous statistical fluctuation of fluorescence becomes the main factor in FCS analisys. During the time that the conjugated-dye cross the volume detection can occur conformational changes, chemical reaction and photophysical processes that can change the emission properties of the dye and, then, change the detected sinal. This fluctuations are tracked and changed into a autocorrelation curve, by a specific software, appropriate to perform FCS analisys. In our study, we use comercial dye (Alexa 488) to label proteins. Firstly, we applied FCS to measure extremally diluted concentrations of dyes (~1 nM). We have performed experiments testing the influence of the viscosity medium in the free difusion of the dyes and the optical apparatus and conditions that result in the best FCS signal. We also have studied protein diffusion (PUC II e IV) in aquous medium (PBS) and toward the inner of the cells.
108

Método de mapeamento espaço-espectral em imagens multi-espectrais e sua aplicação em tecidos vegetais / Spatio-spectral mapping method in multispectral images and their application in plant tissues

Maurício Falvo 26 October 2015 (has links)
Imagens multiespectrais são utilizadas em diferentes aplicações, que vão desde sensoriamento remoto a processos médicos. No caso de imagens multiespectrais oriundas de microscopia confocal de varredura à laser (Confocal Laser Scanning Microscopy-CLSM), a extração da informação se inicia pela conversão das assinaturas espectrais, em uma imagem RGB. Esta imagem é a referência para a seleção da região de interesse, da qual se obtém a assinatura espectral média, originada do arquivo multiespectral (LSM). Mesmo utilizando um padrão muito bem estabelecido de conversão, alguns pontos devem ser considerados: i) o processo de conversão reduz a informação, a uma ordem de 10-145%; ii) a cor é uma experiência sensorial, subjetiva e pessoal, interferindo na seleção da região de interesse e; iii) a assinatura é obtida pela média espectral, da região de interesse, selecionada manualmente.Assim, esta tese de doutorado propõem um método de mapeamento e visualização das informações de imagens multiespectrais, combinando um algoritmo de agrupamento não supervisionado(kmeans) e um algoritmo que define uma paleta de cores coerentes com a informação espectral das regiões mapeadas. Aplicou-se o método em três casos de estudos de tecidos vegetais: i) no pré-tratamento de paredes celulares da cana-de-açúcar; ii) na plasticidade foliar do Jacaranda caroba e; iii) no uso de assinaturas espectrais na classificação de plantas do Cerrado. Os resultados demonstraram que o método é bastante robusto, permitindo de forma inovadora a: visualização, análise e comparação de imagens multiespectrais qualitativa e quantitativamente, e que seu uso é viável em qualquer área de pesquisa que utilize imagens multiespectrais. / Multispectral images are used in different applications, ranging from remote sensing images to medical images. In the case of multispectral images derived from confocal laser scanning microscopy (CLSM), the extraction of information begins with the conversion of spectral signatures in an RGB image. This is the reference for selecting the region of interest, from which it gets the average spectral signature, originated from multispectral file (LSM). Even using a very well established pattern of conversion, some points should be considered: i) the conversion process reduces the information on the order of 10-145%; ii) the color is a sensory experience, subjective and personal, interfering in the selection of the interest region and; the signature is obtained by the spectral average, from interest region which is selected manually. Thus, this doctoral thesis proposes a method of mapping and visualization of multispectral imaging information, combining an unsupervised clustering algorithm (kmeans) and an algorithm that defines a consistent color palette with the spectral information of mapped regions. The proposed method was applied in three cases plant tissue studies: i) in the pre-treating the cell walls of sugarcane; ii) in the leaf plasticity of Jacaranda caroba; iii) in the use of spectral signatures in the Cerrado plant classification. The results showed that the proposed method is quite robust. It presents innovation to the visualization and analysis of multispectral images and makes possible a qualitative and quantitative comparison of a group of multispectral images. Besides that, its use is feasible in any area of research, which are using multispectral images.
109

Influência da agitação de 4 cimentos com ultrassom na capacidade seladora, penetrabilidade dentinária e qualidade da obturação pela técnica da condensação lateral ativa / Influence of ultrasonic agitation of 4 root canal sealers on the sealing ability and obturation quality

Bruno Martini Guimarães 06 May 2013 (has links)
Avaliou-se a adaptação da obturação às paredes do canal, a penetrabilidade dos cimentos nos túbulos dentinários, a qualidade da obturação e a capacidade seladora utilizando-se quatro cimentos obturadores a base de resina epóxi (AH Plus, AcroSeal, AdSeal e Sealer 26), quando submetidos a agitação ultrassônica no momento da inserção do cimento. Foram utilizados 84 caninos humanos recém extraídos, unirradiculados e que foram divididos em dois grupos A e B (n=40), sendo que cada grupo foi dividido em quatro subgrupos de 10 dentes cada, conforme o cimento empregado: A1 e B1 - AH Plus, A2 e B2 Acroseal, A3 e B3 Adseal e A4 e B4 Sealer 26. O preparo biomecânico foi efetuado utilizando-se de instrumentação rotatória com sistema ProTaper, determinando um batente apical com o instrumento F5 (50.05) no comprimento real de trabalho. Foi realizada, em todos os dentes, a padronização do forame até o instrumento Protaper F3. Em seguida, os cimentos foram corados com a Rodamina B. Os canais foram então obturados por meio da técnica da condensação lateral, sendo os canais do grupo A previamente preenchidos pelos cimentos obturadores e submetidos à agitação ultrassônica enquanto que os do grupo B foram considerados como controle e não foram submetidos a agitação. Os dentes então foram submetidos ao teste de infiltração de fluídos após 7 e 30 dias de realizada a obturação. Após esse período, foram realizadas três secções transversais a 2, 4 e 6 mm do ápice e as imagens das secções foram obtidas em estereomicroscópio e microscopia a laser confocal. Para análise entre grupos, no período de 7 e 30 dias em relação ao teste de infiltração apical, foi selecionado o teste não-paramétrico de Kruskall-Wallis e Dunn (p<0.05). Para as demais análises, foi utilizado o teste não-paramétrico Mann Whitney e Wilcoxon. Os resultados indicaram que a agitação ultrassônica aumentou a infiltração apical de forma significante para o cimento AH Plus no período de 7 dias. No que diz respeito à penetração de cimento na dentina, houve um aumento significante para os cimentos AHPus, Acrosela e Sealer 26 no terço médio, e para o AH Plus e Sealer no terço cervical. Com relação às fendas, a agitação ultrassônica favoreceu menor presença desta para o AH Plus na porção apical, e para todos os cimentos na região média e cervical. Concluiu-se que a agitação ultrassônica não proporcionou melhorias no selamento apical e favoreceu maior penetração de cimento na dentina e menor presença de fendas na região média e cervical. / The aim of this study was to evaluate the adaptation of the filling of the canal walls, the penetration of cements in the dentinal tubules, the quality of the filling and sealing capacity utilizing four different epóxic based sealers (AH Plus, Acroseal, AdSeal and Sealer 26), when submitted to ultrasonic agitation at the time of the obturation. Eighty four extracted uniradicular human canines were utilized, and they were divided into two experimental groups A and B (n = 40), and each group was divided into four groups of 10 teeth each, in accordance with the cement used: A1 and B1 - AH Plus, A2 and B2 - Acroseal, A3 and B3-Adseal and A4 and B4 - Sealer 26. The biomechanical preparation was performed utilizing rotary instrumentation with theProTaper system, determining an apical stop with a F5 instrument (50.05) in the real working length. The standardization of the foramen was performed on all teeth until the Protaper F3 instrument. The cements were stained with Rhodamine B. Next the canals were filled by the lateral condensation technique. The canals of group A were previously filled by the sealers and submitted to ultrasonic agitation while those in Group B were considered as the controls and were not subjected to agitation. The teeth were then submitted to testing for leakage of fluids 7 and 30 days after the obturation. After this period, three transverse cross sections were performed at 2, 4 and 6 mm from the apex and the images of the sections were obtained in a stereomicroscope and confocal laser microscopy. For the analysis between the groups, in the period of 7 and 30 days, in relation to the apical leakage test, was selected the nonparametric Kruskal-Wallis and Dunn tests (p <0.05). For the other analyzes, the nonparametric Mann Whitney and Wilcoxon tests was used. The results indicated that the ultrasonic agitation significantly increased apical leakage for the AH Plus in the period of 7 days. With regard to the penetration of the cement into the dentin, there was a significant increase for the AHPus, Acroseal and Sealer 26 cements in the middle third, and the AH Plus and Sealer 26 in the cervical third when the ultrasonic agitation was performed. Regarding the cracks, the ultrasonic agitation favored a smaller presence for the AH Plus in the apical portion, and for all cements in the middle region and cervical. It was concluded that the ultrasonic agitation did not improve the apical seal and favored greater penetration of cement into the dentin and less presence of cracks in the middle and cervical region.
110

Análise da interface de adaptação de diferentes materias obturadores resinosos / Analysis of adaptation interface from different resin filling materials

Marcelo de Morais Vitoriano 25 June 2013 (has links)
Neste trabalho foi avaliado microscopicamente a interface de adaptação entre diferentes cimentos obturadores resinosos e dentina no interior do canal radicular de pré-molares humanos, identificando microscopicamente o nível de adaptação. Foram selecionadas 60 raízes de dentes uniradiculados, raízes retilíneas, com anatomia circular ou ovalada, ápices completos, obtidos por meio de doação feita por Cirurgião Dentistas e, consentidos seu emprego em pesquisas pelo paciente. Posteriormente as raízes foram divididas randomicamente em três grupos de acordo com o sistema de obturação empregado: Grupo 1 Guta-percha + cimento AHPlus; Grupo 2 Real Seal; Grupo 3 Sistema obturador smart-seal. Em seguida cada espécime recebeu cortes transversais em diferentes níveis, com 2mm de espessura, com disco diamantado, em máquina de corte de tecido duro (Isomet®) sob abundante irrigação. Após a realização dos cortes, as fatias a 2mm, 4mm, 6mm e 8mm foram analisadas em esteriomicroscópio, observando-se a área de adaptação cimento-dentina e em microscópio confocal para analisar a penetração do cimento em túbulos dentinários e a presença de fendas. As imagens obtidas foram analisadas pelo software de medida de área Image J®, em que as imagens foram devidamente calibradas. Os resultados apontaram uma superioridade do sistema Smart-seal na área de cimento no corte de 6mm (p<0,05), contudo uma inferioridade no que se tratou da penetração do cimento em túbulos dentinários nos cortes de 2mm, 6mm e 8mm (p<0,05). Em relação as fendas o smart-seal apresentou uma menor quantidade de fendas (p<0,05) apenas na medida de 8mm. Concluiu-se que apesar de sofrer expansão na tomada de presa, e melhor adaptação nas paredes do canal o sistema Smart Seal não apresentou penetrabilidade tubular satisfatória. / This study evaluated microscopically the interface adaptation between sealer and dentin within the root canal, identifying the level of sealing provided by different resin filling materials. 60 single rooted teeth were selected, roots straight with circular or oval anatomy, complete apexes, obtained through donation made by Surgeon Dentists and consented to its use in research by the patient. Subsequently the roots were randomly divided into three groups according to the system obturation: group 1 - Gutta-percha + cement AHPlus, Group 2 - Epiphany + Resilon, Group 3 - Smart Seal obturation system. Then each specimen received a transverse cut with 2 mm thick, with a diamond disc, cutting machine for hard tissue (Isomet ®) under abundant irrigation. After the cuts, slices to 2mm, 4mm, 6mm and 8mm were analyzed by esteriomicroscopy, observing the adaptation area between dentin and sealer, confocal microscopy was utilized to examine the penetration of cement into the dentinal tubules and the presence of gaps. The images were analyzed by software measurement area Image J ®, where the images have been properly calibrated. The results showed a superiority of Smart-seal in the area of cement in cutting 6mm (p <0.05), however inferiority in the penetration of the sealer into the dentinal tubules in sections of 2mm, 6mm and 8mm (p <0.05). Regarding the cracks Smart Seal had a smaller amount of cracks (p <0.05) only the extent of 8mm. It was concluded that although the Smart Seal system presentes expansion and better fit into the dentin walls of the canal, the system showed no satisfactory tubular penetration.

Page generated in 0.0296 seconds