• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 319
  • 144
  • 14
  • 10
  • 8
  • 6
  • 5
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 568
  • 568
  • 275
  • 248
  • 240
  • 203
  • 191
  • 143
  • 141
  • 127
  • 122
  • 107
  • 107
  • 106
  • 98
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Metodologia de análise de variações de tensão causadas pela proteção anti-ilhamento de geradores síncronos distribuídos / Methodology for analysis of voltage variations caused by anti-island protection of distributed synchronous generators

Klaus Vieira do Nascimento 17 June 2013 (has links)
Nos últimos anos, fatores como a reestruturação do setor de energia elétrica, a necessidade de aproveitamento de diferentes fontes primárias de energia, dificuldades na construção de grandes unidades geradoras e linhas de transmissão causadas por normas de proteção ambiental têm provocado o aumento considerável do interesse por geração distribuída. O conceito de geração distribuída tornou-se muito interessante, entretanto, sua aplicação pode provocar problemas de qualidade de energia elétrica, caso sua influência não seja devidamente estudada. Neste contexto, este documento caracteriza as variações de tensão causadas pela atuação da proteção anti-ilhamento de geradores síncronos distribuídos. Este problema pode ser considerado uma nova abordagem sobre os impactos dos geradores distribuídos na qualidade da energia elétrica, visto que as causas das variações de tensão são tipicamente relacionadas às tomadas ou alívios de grandes blocos carga, partidas de motores de indução, curtos-circuitos, desligamentos de linhas etc. Para estudar o problema, inicialmente foi feito um estudo sobre normatização técnica da área com um apanhado dos guias de diversas concessionárias. Posteriormente, simulações computacionais utilizando o programa SimPowerSystems e um sistema teste foram utilizados para que análises estáticas e dinâmicas do problema fossem feitas no intuito de investigar a natureza das variações de tensão e os fatores que influenciam suas magnitudes e durações. Índices para avaliar as variações de tensão foram criados, e um método para obtenção dos mesmos foi proposto. Tal método utiliza apenas ferramentas de análise estática (fluxo de carga) para a obtenção dos índices, evitando o uso de ferramentas dinâmicas (domínio do tempo) reduzindo o custo computacional e financeiro para análise do problema. Em seguida, o mesmo foi aplicado a um sistema que simula uma rede de distribuição real propondo-se a inserção de bancos de capacitores como medida mitigatória para o problema estudado neste trabalho. / In recent years, factors such as the restructuring of the electricity sector, the necessity to use different primary energy sources as a way to diversify sources of energy, barriers in the construction of large generating units and transmission lines caused by environmental protection standards, as well as technological advances in the generation of electricity, have caused a considerable increase in the interest for distributed generation. The concept of distributed generation has become very interesting; however, its application can result in poor power quality, if its influence is not well studied. In this context, this document characterizes voltage variations caused by the action of anti-islanding protection of distributed synchronous generators. This problem can be considered a new approach on the impact of distributed generators in power quality, since the cause of voltage variations are typically related load switching, induction motors start-up, short circuits, lines disconnection, etc. To investigate the problem, initially a study was carried out on technical standardization in the area with an overview of various utilities guides. Later, computer simulations using the SimPowerSystems software and a test system were employed for static and dynamic analysis of the problem, aiming at investigating the nature of voltage variations and the main factors that influence their magnitudes and durations. Indices to assess the voltage variations were created, and a method for obtaining them was proposed. This method uses only static approach tools (power flow calculations) to obtain the indices, avoiding the use of dynamic tools (time-domain simulations) and reducing computational and financial costs to analyses the problem. The proposed method was applied to a larger system and the insertion of capacitors bank was proposed as mitigating solution for the problem studied in this work.
182

Metodologia para avaliação da influência de geradores distribuídos nos níveis de curto-circuito em sistemas de distribuição de energia / Methodology for assessment of distributed generators Influence on short circuit levels of power distribution systems

Daniel Petean 27 February 2015 (has links)
A instalação de geração distribuída nas redes de distribuição e de subtransmissão de energia elétrica tem apresentado significativo crescimento em âmbito mundial, impulsionada pelos benefícios que pode proporcionar aos sistemas elétricos, pela necessidade de diversificação da matriz energética dos países, pela desregulamentação do setor de energia elétrica em diversos países e pela necessidade de gerar energia elétrica de forma sustentável. No entanto, para que os geradores distribuídos possam de fato beneficiar a operação das redes elétricas, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, destaca-se a elevação do nível de curto-circuito da rede, pois correntes de curto-circuito com valores elevados podem causar violação das capacidades dos equipamentos em suportar os esforços térmicos e dinâmicos e também provocar a perda da coordenação entre os dispositivos de proteção contra sobrecorrente. Neste contexto, este trabalho analisa a influência de geradores distribuídos baseados em inversores na corrente de curto-circuito trifásica em um sistema de distribuição de energia, e sobretudo, comprova que sua contribuição no valor da corrente de falta não supera o dobro de sua corrente nominal. Além disso, com base nesta comprovação, apresenta duas estratégias para inserção desse tipo de gerador nos cálculos de curto-circuito de um sistema de distribuição de energia elétrica. As duas estratégias apresentam resultados satisfatórios, utilizam conceitos básicos de circuitos elétricos, independem de dados minuciosos dos inversores e são validadas através de aplicações numéricas com resultados confrontados aos obtidos das simulações. / The installation of distributed generation in distribution and subtransmission systems has shown significant growth worldwide, driven by the benefits it can provide to electrical systems, the need to diversify the energy sources, deregulation of the electricity industry in several countries and the need to generate electricity in a sustainable manner. However, in order to evaluate if distributed generators benefit the operation of power networks, their technical impacts should be carefully studied, especially in distribution networks, which were originally designed to operate with unidirectional power flow. Among the aforementioned impacts, there is the increase of the short circuit level in the distribution network, since high short-circuit currents may exceed the capabilities of equipment to support the dynamic and thermal stresses and also cause loss of coordination between the overcurrent protection devices. Within this context, this thesis analyzes the influence of inverter based distributed generators on three-phase short circuit currents in a power distribution systems. Especially it confirms that the contribution to the fault current does not exceed twice its rated value. Furthermore, based on this issue, this work presents two strategies for the inclusion of this type of generator in short circuit calculations. Both strategies presented satisfactory results, use basic concepts of electrical circuits, they do not depend on detailed data from the inverters and the results are validated by using simulation results.
183

A integração da geração fotovoltaica distribuída à matriz elétrica brasileira: uma análise sob a ótica institucional / The integration of the photovoltaic distributed generation on Brazilian electric matrix: an analysis from the institutional perspective

João Marcos Mott Pavanelli 19 December 2016 (has links)
A matriz brasileira de energia elétrica foi construída historicamente como resultado da confrontação de interesses econômicos, políticos e sociais. Graças a avanços tecnológicos, o setor elétrico brasileiro passa por uma fase de possível inserção de novos modelos, como a geração distribuída de fontes energéticas alternativas, como eólica, biomassa e solar fotovoltaica. Este trabalho oferece uma análise institucional para a compreensão das possibilidades de inserção da geração distribuída fotovoltaica na rede elétrica. Essa análise institucional foi feita através de uma triangulação de técnicas, partindo de revisão bibliográfica de literatura científica, que gerou um modelo analítico para identificar e classificar os principais marcos históricos que direcionaram a estruturação da matriz energética brasileira. Os dados foram confrontados com as entrevistas em profundidade com especialistas do setor elétrico. Os resultados fundamentaram modelos que descrevem a formação histórica de instituições sob os aspectos econômicos, técnicos e normativos. Além disso, os resultados indicam um cenário favorável para investimentos em geração distribuída fotovoltaica até o final da década de 2020, mas também sugerem um possível conflito de equacionamento de custos entre os geradores distribuídos e as concessionárias de distribuição de energia elétrica / The Brazilian electric matrix was built historically as a result of the confrontation among economic, political and social interests. Given the technological advance, the Brazilians electric sector can introduce new models of electric generation, as the distributed generation from alternative energy sources as wind, biomass and photovoltaics. This study offers an institutional analysis to comprehend the perspectives of introducing distributed generation from photovoltaics on Brazilian electric network. This institutional analysis undertook a triangulation of techniques, starting from a literature review, which supported an analysis model. This model was used to identify and classify the main historic marks that constrained the choices concerning the Brazilians electric matrix composition. Historical data was confronted to in-depth interviews with specialists of the Brazilians electric sector. Results supported models which describe the historic formation of institutions under economic, technical and normative aspects. Furthermore the results indicate a favorable scenario to invest in distributed generation from photovoltaic systems in Brazil, at least until 2020, but they also forecast a possible conflict concerning the balance of some costs between the local energys distributor and the owners of distributed generation systems
184

Modelo de análise de pseudo-cooperação de geração distribuída em micro redes. / Analyse model of pseudo-cooperation of distributed generation in micro grid.

Paulo Henrique Ramalho Pereira Gama 10 April 2007 (has links)
A recente abertura de mercado, a carência de recursos públicos para investimentos em geração de energia, a dificuldade de realização de empreendimentos de grande porte por razão ambiental, bem como o programa de universalização do atendimento têm criado novas oportunidades no Setor Elétrico brasileiro, dentre as quais está a exploração de geração distribuída. Nesse âmbito, as micro redes que associam vários geradores de pequeno porte, operados por centro regional, vêm se revelando como uma interessante solução tanto para o investidor como para o atendimento de áreas de concessão específicas. Esta pesquisa apresenta um modelo de análise econômica da participação de geradores distribuídos, operando de forma pseudo-cooperativa, fundamentado na teoria dos jogos. O modelo foca o cliente, com futuro potencial de ser livre, capaz de gerar a sua própria energia através de geradores distribuídos. Uma micro-rede de geradores distribuídos pode ser constituída de vários agentes que, não obstante tenham toda ou parte de sua produção contratualmente comprometida, resolvem atuar de forma cooperada para auferir o ganho decorrente dos diferentes custos marginais de operação das máquinas, para cada nível de despacho de suas unidades. O modelo proposto prevê que a otimização da participação dos despachos das unidades cooperadas, em cada situação de carga, é obtida pela minimização global dos custos marginais totais, determinando a produção de cada gerador. O compartilhamento doganho advindo da cooperação é dado pela aplicação da Função de Shapley, que se fundamenta nas características técnicas e econômicas de operação de cada unidade. ) O modelo desenvolvido neste trabalho formulou o conceito pseudo-cooperação, que prevê a disponibilidade parcial da capacidade de geração de um ou mais agentes para produção dedicada à demanda cooperada da micro rede, de forma que a capacidade restante permanece para o agente oferecer a oportunidades do mercado. A otimização dos ganhos, tanto da rede cooperada como do agente que disponibiliza parte de sua capacidade ao mercado, é realizada através do compartilhamento do ganho da cooperação, da receita obtida da venda de energia ao mercado e do prêmio que o(s) agente(s) que transgride(m) sua(s) cota(s) mínima(s) de cooperação paga(m) aos participantes da cooperação. Com essa abordagem de cooperação parcial e otimização dos ganhos tornou-se possível maximizar os benefícios para os agentes e obter uma capacidade adicional, chamada neste trabalho de \"Sobra\", disponível para venda ao mercado. Desta forma, e como conclusão principal, pôde-se verificar que é possível a obtenção de ganhos adicionais sempre que um ou mais geradores trabalham de forma cooperada e que a pseudo-cooperação apresenta uma forma de aumentar esse ganho / The recent market expansion, the lack of public resources for investments in power generation, the difficulty of deployment of large projects due to environmental reasons, and also the program \"Universalização do Atendimento\" (program that aims to attend all country) has provided new opportunities on the Brazilian Electric Sector. One of these opportunities is the exploration of distributed generation. Under this idea, an interesting solution for the investor and also for the service provider in specific concession areas is the micro-grids. The micro-grids associate several small load generators it selves and these micro-grids are operated by regional centers. This research presents a model of economical analysis of the participation of distributed generators, operating in a pseudo-cooperative way, based in the game theory. The model adresses non free consumers that further may have the capability to be able to generate its own energy through distributed generators, as free consumers. A micro-grid of distributed generators can be composed by several agents that decide to act in a cooperative way aiming to earn from each level of dispatched power, through the different operational cost of the machines in the micro-grid. This is possible even having all or part the production already contractually committed. For each load situation, the proposed model foresees that the dispatch of power in each cooperated units is optimized by the global reduction of the costs thataffect the production of each generator. The share of the gain from the cooperation is given by the application of the Shapley function that is based in the technical and economical characteristics of operation of each unit. ) The developed model in this work has formulated a pseudo-cooperation concept, which foresees the partial availability of the generation capacity of one or more agents for dedicated production to the cooperated demand of the micro grid, so that the remaining capacity is available to be offered to opportunities of the market. The optimization of the gain over the cooperated grid, and also over the agent that make available its partial capacity to the market, is accomplished through the share of the cooperated gain, through the revenue obtained from the energy sold to the market, and also through the prize that the agents pay to other participants of the cooperation when they reach their minimal commitment. With the partial cooperation and gain optimization approach, it was possible to maximize the benefits for the agents and to obtain a surplus, called in this work of \"Sobra\", available to sell to the market. The main conclusion is that it is possible to obtain additional benefits whenever one or more generator work in a cooperative basis and that the pseudo-cooperation is a way to grown this benefits.
185

Controle e análise de conversores CC-CA conectados em redes de distribuição e utilizados em sistemas de geração distribuída / Analysis and control of DC-AC power converters connected to a distribution grid and use in distributed generation system

Amílcar Flamarion Querubini Gonçalves 14 March 2011 (has links)
O presente trabalho visa o desenvolvimento de metodologias para a conexão de sistemas de Geração Distribuída (GD) em redes de distribuição utilizando conversores CC-CA como também, a produção de energia elétrica dentro dos padrões estabelecidos por normas nacionais e internacionais. Para a produção de energia com índices de qualidade satisfatórios, duas situações vão ser consideradas: uma quando o sistema está conectado à rede e outra quando a rede está indisponível. Após a ocorrência do ilhamento, é necessária a mudança da variável a ser sintetizada pelo conversor CC-CA, ou seja, antes da contingência ocorrer a GD está sendo gerenciada no modo potência e/ou corrente e após passa a ser controlada no modo tensão. Além disso, espera-se que os resultados obtidos forneçam subsídios às concessionárias de energia elétrica e aos produtores e autoprodutores de energia para a conexão sistemas de geração distribuída em redes de distribuição como também, os procedimentos necessários a serem adotados por eles quando o sistema de distribuição estiver sob contingência (ilhamento). / This work proposes a set of analysis to connecting a distributed generation system to a distribution network using a three-phase power converter (DC-AC) as well as, the power generation produced by the DG (Distributed Generation) system must follow the national and international power quality standards. For producing energy with satisfactory power quality indexes, two situations will be considered: when the power converter operates connected to the grid, the power/current is used as control variable. However, if the power converter is operating in stand-alone mode (contingency or islanding mode) the control variable must be changed to voltage and the terminal voltage of the power converter must be controlled. Finally, the main concerning of the present study is to obtain results to the electrical energy companies and self-producers for connecting DG system to the grid as well as, the essential procedures that must be adopted by them when the distribution system is operating in contingency or islanding mode.
186

Avaliação da estabilidade de tensão nos sistemas de distribuição considerando a injeção de potência da geração distribuída / Voltage stability assessment in distribuition systems considering the power injection by distributed generation

Alves, Alessandro Arjona 01 April 2016 (has links)
Made available in DSpace on 2017-07-10T16:41:33Z (GMT). No. of bitstreams: 1 Dissertacao Alessandro Arjona Alves2 - Final.pdf: 1729270 bytes, checksum: eaef13266354526fc7d7558b8d6748d0 (MD5) Previous issue date: 2016-04-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The huge rise in electricity energy demand seen in recent decades, the growing interest in alternative and renewable energy sources have placed the distributed generation (DG) in evidence in the global energy landscape. This scenario brings a significant growth in the use of this energy source. Thus, different types of interface and primary sources of energy, with the possibility of allocating different points in the network and with different capabilities, distributed generation brings different impacts to the distribution systems, including power system voltage stability. The voltage stability in networks with distributed generation is the object of this study. To this end, it has been studied methods for power flow calculation, the fundamental concepts of voltage stability and methods of analysis. The aim of this research is to evaluate the distributed generation impact on the voltage stability. Therefore, it has been evaluated some technical aspects such as power factor, location and generation capacity. Through the development of the analysis it was possible to highlight the relationship between improvement in stability margin and the benefit in reducing losses caused by GD. Also it was found that, with a view to improving the margin of voltage stability, it is more efficient to inject power in the network with the same power factor of the system equivalent load. / O grande aumento de demanda por energia elétrica verificado nas últimas décadas, o crescente interesse por fontes alternativas e renováveis de energia tem colocado a geração distribuída (GD) em evidência no panorama energético mundial. Esse cenário propiciou um grande crescimento do uso deste tipo de fonte de energia. Assim, com diferentes tipos de interface e de fontes primárias de energia, com a possibilidade de alocação em distintos pontos da rede e com diferentes capacidades, a geração a distribuída traz diferentes impactos às redes de distribuição, inclusive à estabilidade de tensão dos sistemas. A estabilidade de tensão em redes com presença de geração distribuída é o objeto de estudo desta dissertação de mestrado. Neste sentido, são estudados os métodos para cálculo de fluxo de potência, os conceitos fundamentais da estabilidade de tensão e métodos de análise. O objetivo deste trabalho de pesquisa é avaliar os impactos da geração distribuída na estabilidade de tensão. Para tanto, foram avaliados alguns aspectos técnicos como fator de potência, localização e capacidade de geração. Através das análises desenvolvidas foi possível destacar a relação entre melhora na margem de estabilidade de tensão e o benefício em redução de perdas ocasionado pela GD. Também constatou-se que, com vistas à melhora da margem de estabilidade de tensão, é mais eficiente injetar potência na rede com o mesmo fator de potência da carga equivalente do sistema.
187

Análise do comportamento transitório de geradores distribuídos eólicos e fotovoltaicos conectados num mesmo alimentador / Analysis of the transient behavior of wind and photovoltaic distributed generators connected in the same electric feeder

Bainy, Rômulo Gonçalves 09 March 2015 (has links)
Made available in DSpace on 2017-07-10T17:11:49Z (GMT). No. of bitstreams: 1 Romulo Bainy2.pdf: 2925977 bytes, checksum: f7adb8982457ac4631549de0def5054e (MD5) Previous issue date: 2015-03-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work evaluated the effect of the variation of some factors over the transient behavior of a feeder from a Distribution Power System where there are Distributed Generator (DG) connected. Two types of distributed generation were evaluated, which are photovoltaic and wind power. The chosen Distribution Power System has 32 nodes and was presented by (de Abreu, 2005) and (Salim, 2010). First of all, this feeder was characterized and the nodes were separated on four clusters, comply some electric characteristics from each one. Each cluster has a chosen node that represents the center of the group from the cluster, which resulted on four candidates nodes. Than, it was time to build the scenarios for simulation, they were made by two candidate node and fault node, which means that there are six possible scenarios. To chose the fault node, there is some premises: None of GD can generate on a islanded operation; It is not necessary that all scenarios has the same fault node; and, the more important one, the fault node must have fault current similar on all scenarios. The studied factors were: Loading of the feeder; Power factor of the loads; X/R relation of lines; GFV conexion; FSIG conexion. The simulation evaluated the influence of each factors. Among the five , only two showed influence in the transient behavior of the system: the connection ratio X/R and the FSIG conexion . The other three did not shown influence. Thus, the two factors correspond to valuable study object , and should be considered when evaluating the transient behavior at Distribution System with DG. / Este trabalho avaliou a influência de alguns fatores sobre o comportamento transitório de um alimentador de um sistema de distribuição com geradores distribuídos conectados. Dois tipos de geração distribuída foram avaliados, sendo eles a fotovoltaica e a eólica. O sistema elétrico de distribuição (SED) escolhido possui 32 nós e foi apresen-tado por (de Abreu, 2005) e em (Salim, 2010). Primeiramente este alimentador foi caracterizado e os nós separados em 4 clusters, conforme algumas características elétricas de cada um. Para cada cluster um nó foi escolhido como representante das centroide, ou seja, mais similar com a identidade do grupo. O trabalho seguiu com a concepção dos cenários de simulação, estes compostos pela junção destes quatro nós em duplas, além do nó de falta, o que se traduz em seis possíveis cenários. A escolha do nó para inserção de um curto-circuito trifásico respeitou três premissas: não causar ilhamento em nenhum dos geradores distribuídos; não é necessário que o nó de falta de todos os cenários seja igual; e, a premissa mais importante, que ele deve gerar uma corrente de falta com valor similar em todos os cenários.Os fatores avaliados foram: Carregamento do Alimentador; Fator de Potência das Cargas; Relação X/R das linhas de distribuição; Conexão do GFV; Conexão do FSIG.Cada um dos fatores sofreu uma quantidade específica de variações para que seu efeito sobre o comportamento transitório fosse investigado. Dentre esses cinco, apenas dois se mostraram capazes de influenciar no comportamento transitório do sistema: a relação X/R e a conexão do FSIG. Os outros três não demonstraram grande influência, sendo sempre imperceptível o efeito de sua variação. Dessa forma, a variação dos dois fatores corresponde a valioso objeto de estudo, sendo necessário considerá-los quando se deseja avaliar o comportamento transitório de um Sistema de Distribuição com geradores distribuídos.
188

Análise de um mecanismo de compensação de reativos incorporado aos inversores de um sistema fotovoltaico conectado à rede elétrica / Analysis of a reactive power compensation mechanism incorporated into inverters of a grid-connected photovoltaic system

Benedito, Ricardo da Silva 14 November 2014 (has links)
No Brasil, quando uma unidade consumidora (UC) sob regime de microgeração ou de minigeração distribuída tem parte ou a totalidade da sua demanda por potência ativa suprida pela planta geradora, mas sua demanda por potência reativa é atendida exclusivamente pela rede elétrica, verifica-se uma aparente deterioração do fator de potência dessa UC, sob a ótica da concessionária. Esse efeito decorre do fato de que o fator de potência, de acordo com a regulamentação vigente, é determinado apenas a partir das medições dos fluxos de potência ativa e reativa trocados entre a UC e a rede elétrica e não também entre a planta geradora e UC. Para consumidores do Grupo A (tensão de fornecimento igual ou superior a 2,3 kV) nessa situação, de acordo com o perfil da carga, pode haver cobrança por excedentes de reativos, constituindo-se assim uma barreira. Especificamente no caso de sistemas fotovoltaicos conectados à rede, existe a possibilidade de se utilizar os próprios inversores c.c.-c.a para suprir a demanda de reativos da UC e, dessa forma, minimizar o problema apresentado. Com o objetivo de se avaliar essa alternativa no contexto brasileiro, tendo-se em vista condições reais de operação e os limites normativos de injeção de potência reativa para inversores de sistemas fotovoltaicos, foi realizado um estudo de caso de uma planta fotovoltaica instalada no telhado do prédio da Administração do Instituto de Energia e Ambiente da Universidade de São Paulo. O estudo mostrou que a compensação realizada por meio do inversor selecionado evitou a cobrança de excedentes de reativos sem afetar de forma significativa a produtividade do sistema fotovoltaico. Do ponto de vista elétrico, verificou-se que a injeção de reativos pelo inversor não provocou variações significativas de tensão no ponto de acoplamento ou no alimentador e, ainda, se verificou considerável liberação de capacidade do sistema supridor da concessionária. Dessa forma, a análise dos resultados indica uma tendência a se considerar a compensação de reativos proporcionada pelo próprio inversor a opção mais viável para se lidar com os excedentes de reativos, comparativamente a métodos convencionais de compensação ou à situação em que nenhuma ação compensatória seja implementada. / In Brazil, when a consumer unit (CU) under a distributed microgeneration or minigeneration scheme has part or all of its demand for active power supplied by the generating plant, but its demand for reactive power is served exclusively by the grid, the power factor of this CU appears deteriorated, from the perspective of the utility. This effect is due to the fact the power factor, according to the current regulations, is determined only from measurements of the flows of active and reactive power exchanged between the UC and the grid and not also between the generating plant and UC. Users of group A (supply voltage equal to or greater than 2.3 kV) in this situation, according to the CU load profile, may be charged due the reactive power excess, thus constituting a barrier. Specifically in the case of grid-connected photovoltaic systems, there is the possibility of using the d.c.- a.c. inverters to suply the CU reactive power demand and, thus, minimizing the presented problem. In order to evaluate this alternative in the Brazilian context, keeping in view real operating conditions and regulatory limits for the reactive power injection for photovoltaic inverters, we conducted a case study with a photovoltaic plant installed on the roof of the University of São Paulo Institute for Energy and Environment administration building. The study showed that the compensation performed by the selected inverter prevented the reactive power excess charging without affecting significantly the photovoltaic system productivity. From an electrical point of view, it was found that the injection of reactive power by the inverter did not cause significant voltage variations at the coupling point or at the transformer and, additionally, there was a significant release in the utility suply system capacity. Thus, the analysis results indicates a tendency to consider the compensation provided by the inverter itself the most viable option for dealing with the surplus of reactive power compared to conventional compensation methods or to the situation in which no compensatory action is implemented.
189

Barreiras e potencialidades à difusão de geração fotovoltaica, conectada à rede de distribuição, no estado do Tocantins

Paula, Juci José de 15 July 2016 (has links)
Submitted by Silvana Teresinha Dornelles Studzinski (sstudzinski) on 2016-09-21T13:59:53Z No. of bitstreams: 1 Juci José de Paula_.pdf: 8768993 bytes, checksum: 367b45dfb9f603b93805a677e010f61d (MD5) / Made available in DSpace on 2016-09-21T13:59:53Z (GMT). No. of bitstreams: 1 Juci José de Paula_.pdf: 8768993 bytes, checksum: 367b45dfb9f603b93805a677e010f61d (MD5) Previous issue date: 2016-07-15 / Nenhuma / Em países como Alemanha, Japão, Estados Unidos e China a geração fotovoltaica ocupa lugar de destaque entre suas principais fontes geradoras de energia elétrica. No Brasil a geração fotovoltaica está sendo timidamente introduzida, contudo, ainda, não se destaca como fonte de energia elétrica em sua matriz elétrica. Há evidências de que a inércia, em seu desenvolvimento, está relacionada a barreiras econômicas, regulatórias, institucionais e de mercado. No intuito de encontrar os fatores que impedem sua difusão no estado do Tocantins, este trabalho busca através de um estudo de caso com a aplicação do método do pensamento sistêmico, gerar conhecimento sobre as principais barreiras ao uso desta fonte, objetivando atender à crescente demanda por energia elétrica e possibilitando uma popularização das fontes renováveis. Na primeira fase gerou-se um entendimento melhor sobre o tema pesquisado. Após, realizou-se entrevistas com especialistas que proporcionaram o entendimento da atual situação da difusão de sistemas fotovoltaicos no estado, confirmando a existências de barreiras e criando base para elaboração de miniestruturas sistêmicas que, posteriormente, foram consolidadas em uma única estrutura apresentando os dados encontrados. Os resultados obtidos apresentaram os problemas enfrentados pela geração distribuída fotovoltaica no estado, confirmando a existência de barreiras econômicas, institucionais, de mercado e outras, que atrapalham a difusão desta fonte. Ao final, foram propostas ações que eliminam ou minimizam estas barreiras. / In countries like Germany, Japan, the United States and China, the photovoltaic power generation occupies a prominent place among their main electric energy generating source. In Brazil, the photovoltaic power generation is being timidly introduced. However, it does not stand out as an electric power source in its energetic matrix. There are evidences that its development inertia is related to economic, regulatory, institutional and market barriers. In an attempt to find the factors that prevent its dissemination in the State of Tocantins, this research seeks to engender knowledge about the main hindrances to the use of that source, through a case study, with the application of the systemic thinking method. It aims to meet the increasing demand of electric power and making it possible a popularization of the renewable sources. In the first phase, a better understanding of the studied topic was carried out. Thereupon, some interviews with specialists were performed. They provided the comprehension of the current situation of the photovoltaic systems diffusion in the state, thus confirming the existence of obstacles and creating a basis for the preparation of systemic mini structures that, subsequently, were consolidated into a single structure, presenting the data encountered. The obtained results demonstrated the problems confronted by the distributed photovoltaic generation in the state, reaffirming the existence of economic, institutional and market barriers among others, what obstruct the spreading of that source. Actions to eliminate or minimize those obstacles were proposed.
190

Programação estocástica aplicada ao planejamento de sistemas de distribuição considerando geração distribuída e emissões de CO2 /

Lima, Tayenne Dias de January 2019 (has links)
Orientador: John Fredy Franco Baquero / Resumo: A presença de Geração Distribuída (GD) no Sistema de Distribuição de Energia Elétrica (SDEE) tem se incrementado nos últimos anos devido a mudanças na regulação e a incentivos governamentais, proporcionando benefícios técnicos e econômicos. Em particular, é esperado que a GD renovável (eólica ou solar) seja integrada adequadamente no SDEE, visando contribuir na redução de emissões de gases de efeito estufa. Entretanto, a presença da GD renovável, junto com suas inerentes incertezas, aumenta a complexidade no planejamento do SDEE. Diante do exposto, neste trabalho propõe-se um modelo de programação estocástica de dois estágios para o problema de planejamento da expansão do SDEE multi-período. As incertezas da geração renovável (associadas à irradiação solar e velocidade do vento) e demanda são representadas por meio de cenários. A função objetivo minimiza o valor presente líquido dos investimentos (subestações, circuitos, e alocação de GD), custo da energia, manutenção e operação, assim como o custo das emissões de CO2. A operação das unidades de GD é representada limitando a potência ativa/reativa que pode ser injetada segundo as curvas de capabilidade e restrições de fator de potência. O modelo proposto foi implementado na linguagem de modelamento AMPL e resolvido com o solver CPLEX. Testes utilizando um SDEE de 24 e 54 nós comprovam a eficiência do modelo. / Abstract: The presence of Distributed Generation (DG) in Electrical Distribution Systems (EDSs) has been increased in recent years due to changes in regulation and government incentives, leading to technical and economic benefits. In particular, renewable DG (wind or solar power) is expected to be properly integrated into the EDS, aiming to contribute to the reduction of greenhouse gas emissions. However, the presence of renewable DG, along with its inherent uncertainties, increases the complexity in the planning of the EDS. In this context, this work proposes a two-stage stochastic programming model for the problem of EDSs expansion planning. The uncertainties of renewable generation (associated with solar irradiation and wind speed) and demand, are represented through scenarios. The objective function minimizes the net present value of investments (substations, circuits, and DG allocation), energy cost, maintenance and operation, as well as the cost of CO2 emissions. The operation of the DG units is represented by limiting the active/reactive power that can be injected according to capability curves and power factor constraints. The proposed model was implemented in the modeling language AMPL and solved with the solver CPLEX. Tests using a 24 and 54-nodes EDS prove the efficiency of the proposed model. / Mestre

Page generated in 0.0796 seconds