Spelling suggestions: "subject:"[een] NATURAL CONVECTION"" "subject:"[enn] NATURAL CONVECTION""
101 |
[en] SOLIDIFICATION AND FUSION OF PURE SUBSTANCES UNDER THE INFLUENCE OF LAMINAR AND TURBULENT NATURAL CONVECTION / [es] SOLIDIFICACIÓN Y FUSIÓN DE SUSTANCIAS PURAS SOBRE LA INFLUENCIA DE CONVECCIÓN NATURAL LAMINAR Y TURBULENTA / [pt] SOLIDIFICAÇÃO E FUSÃO DE SUBSTÂNCIAS PURAS SOB A INFLUÊNCIA DA CONVECÇÃO NATURAL LAMINAR E TURBULENTALUIZ JOAQUIM CARDOSO ROCHA 27 July 2001 (has links)
[pt] Solidificação e fusão fazem parte de uma classe de
problemas transientes de transferência de calor conhecidos
como problemas de mudança de fase ou de fronteira móvel. A
solução desta classe de problemas envolve uma dificuldade
inerente ao processo que é o movimento da interface entre
as fases sólida e líquida. Este movimento está relacionado
à absorção ou remoção do calor latente na interface. Como
conseqüência a localização da interface sólido/líquido não
é conhecida a priori tornando-se parte da solução.
No presente trabalho, considera-se a mudança de fase em
regime transiente de um material puro, na presença de
convecção natural, em uma cavidade fechada bidimensional.
A interface entre as fases sólida e líquida se comporta
como um contorno bem definido com temperatura igual à
temperatura de mudança de fase do material. O material na
fase líquida é considerado um fluido Newtoniano e a
aproximação de Boussinesq é utilizada.
Tanto na região líquida, quanto na região sólida, as
propriedades termofísicas são constantes e uniformes,
porém, diferentes entre si. O sistema de coordenadas
adotado é aquele onde suas coordenadas adaptam-se ao
contorno da geometria, e considera, quando
existe movimento de fronteira e/ou interface, sua
velocidade de deslocamento.
A intensidade na qual o fluido se movimenta provoca
mudanças na forma da interface e é de fundamental
importância no fenômeno da mudança de fase. No começo do
processo de mudança de fase, o modo de transferência de
calor na fase líquida é devido somente à condução de calor.
À medida que a velocidade do fluido aumenta, o processo de
transferência de calor por convecção começa a dominar. O
escoamento ocorre no regime laminar mas eventualmente torna-
se turbulento, o que aumenta significativamente as taxas
de transferência de calor ao longo da interface. Além
disso, como as partículas fluidas se deslocam mais
rapidamente há uma melhor distribuição destas taxas ao
longo da interface, com uma diminuição em sua curvatura.
O modelo de turbulência selecionado pertence à família de
modelos k-e. O modelo k-e tradicional é utilizado no núcleo
turbulento, e um outro conjunto de equaçõesdesenvolvido a
partir de dados de simulação numérica direta, é utilizado
na região próxima às paredes. A metodologia implementada
permite determinar naturalmente a transição do regime
laminar para o turbulento.
O presente trabalho apresenta uma nova metodologia no
tratamento da interface entre as regiões sólida e líquida.
Um volume de controle de espessura zero representa a posição
da interface. Uma vez resolvida a equação do balanço
combinado de massa e energia na interface, nenhum artifício
é necessário para se avaliar sua nova posição. Devido ao
salto de massa específica na interface alguma variação no
volume total do material é esperada.
Entretanto, o modelo atual não prevê aumento no volume
total do material e algum artifício deve ser utilizado para
adicionar ou retirar massa do domínio. A utilização do
volume de controle zero na interface permite retirar ou
adicionar massa sem a necessidade de termos de fonte
adicionais. Também é utilizado o artifício de redistribuir
os pontos nodais entre as fases sólida e líquida no intuito
de não alocar muitos pontos nodais em regiões de pequenas
espessuras. A redistribuição de pontos garante um
refinamento melhor junto à interface e, possibilita a
utilização de maiores intervalos de tempo sem introduzir
dificuldade de convergência.
Os resultados numéricos são comparados a dados
experimentais e resultados numéricos para os processos de
fusão e solidificação de materiais puros.
A boa concordância com dados experimentais revela que a
metodologia apresentada resulta numa melhora na resolução
deste tipo de problemas. / [en] Solidification and fusion belong to a class of transient
heat transfer problems known as phase change problems or
moving boundary problems. The solution of this class of
problems presents an additional difficulty concerning the
movement of the interface. This movement is due to the
absorption or removal of the latent heat at the interface.
As a consequence the position of the interface is not
known, being part of the solution.
At the present work, the transient phase change of a pure
substance is considered in the presence of natural
convection in a closed two dimensional cavity.
The interface is a well-defined boundary at the phase
change temperature. The liquid phase is assumed to be
Newtonian and the Boussinesq approximation is adopted. The
properties of both liquid and solid phases are constant,
although different of each other. A non-orthogonal
coordinate system, which adapts to the geometry, is
employed. This coordinate system moves with
time to adapt to the varying interface position.
The intensity of the fluid movement promotes changes in the
interface shape, and it is extremely important for the
phase change phenomena. At the beginning of the phase
change process, the heat transfer mechanism at the liquid
phase is due only to conduction.
As the fluid velocity increases, the heat transfer by
convection begins to dominate the process. The flow is
laminar, and eventually the fluid flow becomes turbulent,
substantially increasing the heat transfer rate along the
interface. Further, since the fluid particles move
more rapidly, theses heat fluxes along the interface are
better distributed, causing a reduction of the interface
curvature.
The turbulence model selected belongs to the k-e family.
The traditional k-e é employed at the turbulent core and
another set of equations, developed based on direct
numerical simulation data, is employed at the near wall
region. The methodology is capable of determining the
transition from laminar to turbulent flow.
The present works presents a new methodology to determine
the interface between solid and liquid regions. A zero
thickness control volume represents the interface position.
Once the mass and energy balance equations are solved at
the interface, no further schemeis necessary to evaluate
its new position. The zero thickness control volume at the
interface allows the mass to be conserved at the liquid
region without the need of any special treatment, in spite
of the specific mass jump across the interface. The grid
distribution is adjusted between the liquid and solid phase
during the phase change process, in order to optimize the
grid distribution in the domain. Further, the grid
redistribution allows the use of larger time steps, without
convergence difficulties.
The numerical results are compared with experimental and
numerical data available in the literature for fusion and
solidification of pure substances. The good agreement
reveals that the presented methodology furnishes an
improved solution for this type of problems. The point
redistribution allows the specification of larger time
steps without compromising the convergence and precision. / [es] Solidificación y fusión forman parte de una clase de problemas de transferencia de calor conocidos
como problemas de cambio de fase o de frontera movil. La solución de esta clase de problemas
envuelve una dificuldad inherente al proceso: el movimiento de la interfaz entre las fases sólida y
líquida. Este movimiento está relacionado con la absorción o extracción del calor latente en la
interfaz. Como consecuencia, la localización de la interfaz sólido/líquido no se conoce a priori, por
lo
que forma parte de la solución. En el presente trabajo, se considera el cambio de fase en régimen
transitorio de un material puro, en presencia de convección natural, en una cavidad cerrada
bidimensional. La interfaz entre las fases sólida y líquida se comporta como un contorno bien
definido con temperatura igual a la temperatura de cambio de fase del material. El material en
fase
líquida es considerado un fluido Newtoniano, por lo que se utiliza la aproximación de Bousinesq.
Tanto en la región líquida como en la sólida, las propiedades termofísicas son constantes y
uniformes,
aunque diferentes entre sí. El sistema de coordenadas adoptado es aquel donde las coordenadas se
adaptan al contorno de la geometría; y considera su velocidad de deslizamiento cuando existe
movimiento de fronteira y/o interfaz. La intensidad del fluido provoca cambios en la forma de la
interfaz lo que resulta de fundamental importancia en el fenómeno del cambio de fase. Al inicio del
proceso de cambio de fase, el modo de transferencia de calor en la fase líquida se debe solamente a
la conducción de calor. A medida que la velocidad del fluido aumenta, el proceso de transferencia
de calor por convección comienza a dominar. El fujo ocurre en el régimen laminar, pero
eventualmente se vuelve turbulento, lo que aumenta significativamente las tasas de transferencia de
calor a lo largo de la interfaz. Además de esto, como las partículas fluidas se desplazan más
rapidamente, hay una mejor distribución de estas tasas a lo largo de la interfaz, con una disminución
en su curvatura. El modelo de turbulencia seleccionado pertence a la família de modelos k-y. El
modelo k-y tradicional se utiliza en el núcleo turbulento, y se desarrolla otro conjunto de ecuaciones
a
partir de datos de simulación numérica directa, que es utilizado en la región próxima a las paredes.
La metodología implementada permite determinar naturalmente la transición del régimen laminar
para el turbulento. Este trabajo presenta una nueva metodología en el tratamiento de la interfaz
entre las regiones sólida y líquida. El volúmen de control de espesura cero representa la posición de
la interfaz. Una vez resuelta la ecuación del equilibrio combinado de masa y energía en la interfaz,
no se necesita evaluar su nueva posición. Debido al salto de masa específica en la interfaz, se
espera
alguna variación en el volúmen total del material. Sin embargo, el modelo actual no prevee un
aumento en el volumen total del material y se debe utilizar cierto artificio para adicionar o retirar
masa del dominio. La utilización del volumen de control cero en la interfaz permite retirar o
adicionar
masa sin necesidad de términos de fuente adicionales. También es utilizado el artificio de
redistribuir
los puntos nodales entre las fases sólida y líquida con el objetivo de no considerar muchos puntos
nodales en regiones de pequenas espesuras. Esta redistribución garantiza un mejor refinamiento
junto a la interfaz y, posibilita la utilización de mayores intervalos de tiempo sin introducir mayores
problemas de convergencia. Los resultados numéricos son comparados con datos experimentales y
con resultados numéricos para los procesos de fusión y solidificación de materiales puros. La
concordancia con datos experimentales revela que la metodología presentada mejora la resolución
de este tipo de problemas.
|
102 |
Avaliação numérica e experimental da convecção natural em coletor solar de tubos evacuadosManea, Tiago Francisco January 2016 (has links)
O coletor solar de tubos evacuados une uma alta absortividade de radiação solar a um ótimo grau de isolamento térmico. Estas características, aliadas a um custo relativamente baixo, fazem deste tipo de coletor o mais utilizado no mundo. Por isso, diversos tipos de abordagens estão sendo adotadas para descrever seu comportamento térmico. Nesta linha, este trabalho foi desenvolvido através de abordagem experimental e teórica, sendo a última subdividida em numérica por CFD e analítica. A abordagem experimental contou com a construção de uma bancada para medida de temperatura e radiação, em um coletor de 24 tubos evacuados acoplados em um reservatório de 178 L. A abordagem por CFD utilizou um modelo tridimensional transiente. Com o modelo numérico validado, utilizando resultados experimentais, simularam-se diferentes condições de operação, em termos de ângulo de inclinação, fluxo de calor sobre o coletor, tamanho do reservatório e temperatura de entrada da água. Em relação à abordagem analítica, esta é dividida em: modelo de irradiância, modelo do tubo e modelo do reservatório. O modelo de irradiância determina a distribuição da radiação solar ao longo da circunferência do tubo. Parte desta radiação é absorvida pelo coletor e transferida para água. Esta quantidade é determinada com o modelo do tubo, que é baseado no método de resistências térmicas. O modelo do reservatório descreve o comportamento térmico da água em seu interior, tanto em aquecimento quanto em resfriamento, analisando a interação energética com o coletor e com o meio externo. O desenvolvimento do modelo do tubo passa pela avaliação da vazão mássica entre o tubo e o reservatório, além disso, o coeficiente de transferência de calor por convecção no interior do tubo deve ser determinado. Tais variáveis são determinadas a partir de uma correlação para o número de Reynolds, a qual foi obtida com resultados da avaliação por CFD e é função dos números de Nusselt, Grashof e Prandtl. A correlação proposta apresentou bom ajuste com os resultados numéricos. Com a bancada de ensaio experimental foram feitas medidas de temperatura da água no reservatório ao longo de alguns dias. Para as mesmas condições do experimento, a temperatura média da água no reservatório foi estimada com resultados da integração dos modelos de irradiância, do tubo e do reservatório. A diferença entre os resultados experimental e teórico foi de 4,8% para a energia acumulada. / The evacuated tube solar collector combines high solar radiation absorptivity to a great thermal insulation degree. These characteristics, combined with a relatively low cost, make this type of collector the most used in the world. Therefore, various types of approaches are being adopted to describe its thermal behavior. In this way, this work was developed through experimental and theoretical approaches, the latter being subdivided into numeric, by CFD, and analytical analysis. For the experimental approach a test bench was built. The tests was carried on a solar collector with 24 evacuated tubes coupled to a 178 L tank, measuring temperature and solar radiation. The CFD approach used a transient three-dimensional model. After the numerical model validation using experimental data, simulations was carried over different operating conditions in terms of angle, heat flux on the collector, tank size and water inlet temperature. The analytical approach is divided into: irradiance model, tube model and tank model. The irradiance model determines the irradiance distribution of solar radiation along the circumference of the tube. Part of this radiation is absorbed by the collector and transferred to water, this amount is determined with the tube model, using the thermal resistance method. The tank model describes the thermal behavior of inside water, both in heating and in cooling, analyzing energy interaction with the collector and the external environment. The development of the tube model involves the assessment of the mass flow rate between the tube and the tank, furthermore the convection heat transfer coefficient inside the tube must be determined. These variables are determined from a correlation for the Reynolds number, which was obtained with evaluation results by CFD. Proposed Reynolds number is a function of the Nusselt, Prandtl and Grashof numbers. The correlation presented a good agreement with the numerical results. Using the experimental test bench the water temperature was measured into the tank over a few days. For the same experiment conditions, the average temperature of the water into the tank was estimated by results of integration of irradiance, tube and tank models. The difference between the experimental and theoretical results was 4.8% for the accumulated energy.
|
103 |
Estudo da formação de gelo durante o armazenamento a granel de vegetais congeladosUrquiola Mujica, Ana January 2018 (has links)
Este trabalho propõe um modelo de transferência de calor e massa para prever a formação de gelo em um container preenchido com legumes congelados. O problema físico é modelado como um meio poroso composto pelo próprio produto e o ar em seu entorno. O regime de convecção natural é assumido dentro do container, o qual promove o transporte de massa. Como uma primeira validação, o modelo é simulado considerando diferentes temperaturas de ar externo, causadas por flutuações da vizinhança. Resultados para quatro ciclos de temperaturas foram comparados, variando separadamente a temperatura média do ar, amplitude e frequência de oscilação. De modo geral, é observado que a temperatura do produto se comporta assim como era esperado e este resultado é diretamente associado à formação de gelo dentro do container. A formação de gelo cresce com uma maior amplitude de oscilação, porém decresce com um aumento na frequência e na temperatura média. Os parâmetros do modelo foram obtidos para dois diferentes produtos: fatias de cenouras congeladas e vagens congeladas, ambos em meio ao ar. As definições de parâmetros são oriundas de revisão bibliográfica, medições experimentais e simulações numéricas. Os parâmetros encontrados para a caracterização desses meios porosos foram similares para ambos os produtos, mesmo eles possuindo diferentes geometrias. A validação experimental foi feita para as fatias de cenoura considerando dois ciclos de temperatura O modelo numérico é capaz de prever o campo de velocidades do ar, as temperaturas do produto e a formação de gelo local. Os resultados foram validados em relação a um grupo independente de resultados numéricos, tal comparação apresentou uma boa concordância. A circulação de ar encontrada é, de fato, devido à convecção natural. O comportamento da temperatura dos produtos simulados concorda com os valores medidos e os valores de temperaturas diferem por menos de 12%. Com respeito à formação de gelo, o modelo é capaz de prevê-la corretamente nas regiões mais suscetíveis a este fenômeno. Porém, a quantidade de gelo formado prevista pelo modelo (1,56 g/semana) é menor do que a experimental (4,67 g/semana), apesar de serem de mesma ordem de magnitude. O efeito de cada parâmetro no modelo é estudado visando detectar maneiras de aprimorar o modelo. Foi encontrado que os parâmetros mais importantes para a formação de gelo total são a difusividade de massa efetiva e o coeficiente de transferência de calor convectivo dentro do container. Ajustando estes parâmetros duas vezes foi possível encontrar resultados melhores com respeito à formação de gelo (3,09 g/semana). / A model of heat and mass transfer is proposed in order to predict frost formation into a closed container filled with frozen vegetables. The physical problem is modeled as a macroporous media composed by the product itself and the surrounding air. Natural convection air flow is assumed into the container, who promotes water mass transport. As a first validation, the model is simulated for several exterior air temperatures, under environmental fluctuations (boundary conditions). Results of four temperature cycles were compared, varying average air temperature, amplitude and frequency of oscillation, one by one. As a general result, it is observed that the product temperature behavior is as expected, and it is directly associated with frost formation into the container. Frost formation increases with large amplitude of oscillation, but decreases with higher frequencies and higher mean temperatures. Model parameters were obtained for two assembling: frozen slices of carrots and air, and frozen extra thin green beans and air. Parameter definition and evaluation combines literature review, measurements and numerical simulation. In general, parameters which characterize these porous media were similar for both products, even though they display different geometries. The experimental validation is performed for carrot slices with two temperature cycles The numerical model is able to predict air velocity field, air and product temperatures, and local frost formation. Results are validated in respect to a set of independent experimental results that shown a good agreement. Air flow circulation is as expected due to natural convection. Product temperature simulated behavior agrees with measurements, and temperature values differ by less than 12%. Respect to frost formation predictions, the model predicts correctly the most susceptible regions to frost formation. However, the quantity of frost formed predicted by the model (1.56 g/ week)is lower than the experimental one (4.67g/week), despite being of the same order of magnitude. The effect of each parameter in the model is study in order to detect how to improve the model. The most important parameters affecting total frost formation are effective mass diffusivity and convective heat coefficient into the storage container. Adjusting these parameters to twice, better results in terms of frost formation could be obtained (3.09 g/ week).
|
104 |
Análise numérica da dinâmica do escoamento em circuitos de circulação natural / Numerical analysis of the fluid dynamics in a natural circulation loopANGELO, GABRIEL 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:20Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
105 |
Estabelecimento de um sistema padrão primário para raios X baixas com uma câmara de ionização de ar livre de energias / Establishment a primary standard system for low energy X-rays using a free air ionization chamberSILVA, NATALIA F. da 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:43:46Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:43:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
106 |
Avaliação numérica e experimental da convecção natural em coletor solar de tubos evacuadosManea, Tiago Francisco January 2016 (has links)
O coletor solar de tubos evacuados une uma alta absortividade de radiação solar a um ótimo grau de isolamento térmico. Estas características, aliadas a um custo relativamente baixo, fazem deste tipo de coletor o mais utilizado no mundo. Por isso, diversos tipos de abordagens estão sendo adotadas para descrever seu comportamento térmico. Nesta linha, este trabalho foi desenvolvido através de abordagem experimental e teórica, sendo a última subdividida em numérica por CFD e analítica. A abordagem experimental contou com a construção de uma bancada para medida de temperatura e radiação, em um coletor de 24 tubos evacuados acoplados em um reservatório de 178 L. A abordagem por CFD utilizou um modelo tridimensional transiente. Com o modelo numérico validado, utilizando resultados experimentais, simularam-se diferentes condições de operação, em termos de ângulo de inclinação, fluxo de calor sobre o coletor, tamanho do reservatório e temperatura de entrada da água. Em relação à abordagem analítica, esta é dividida em: modelo de irradiância, modelo do tubo e modelo do reservatório. O modelo de irradiância determina a distribuição da radiação solar ao longo da circunferência do tubo. Parte desta radiação é absorvida pelo coletor e transferida para água. Esta quantidade é determinada com o modelo do tubo, que é baseado no método de resistências térmicas. O modelo do reservatório descreve o comportamento térmico da água em seu interior, tanto em aquecimento quanto em resfriamento, analisando a interação energética com o coletor e com o meio externo. O desenvolvimento do modelo do tubo passa pela avaliação da vazão mássica entre o tubo e o reservatório, além disso, o coeficiente de transferência de calor por convecção no interior do tubo deve ser determinado. Tais variáveis são determinadas a partir de uma correlação para o número de Reynolds, a qual foi obtida com resultados da avaliação por CFD e é função dos números de Nusselt, Grashof e Prandtl. A correlação proposta apresentou bom ajuste com os resultados numéricos. Com a bancada de ensaio experimental foram feitas medidas de temperatura da água no reservatório ao longo de alguns dias. Para as mesmas condições do experimento, a temperatura média da água no reservatório foi estimada com resultados da integração dos modelos de irradiância, do tubo e do reservatório. A diferença entre os resultados experimental e teórico foi de 4,8% para a energia acumulada. / The evacuated tube solar collector combines high solar radiation absorptivity to a great thermal insulation degree. These characteristics, combined with a relatively low cost, make this type of collector the most used in the world. Therefore, various types of approaches are being adopted to describe its thermal behavior. In this way, this work was developed through experimental and theoretical approaches, the latter being subdivided into numeric, by CFD, and analytical analysis. For the experimental approach a test bench was built. The tests was carried on a solar collector with 24 evacuated tubes coupled to a 178 L tank, measuring temperature and solar radiation. The CFD approach used a transient three-dimensional model. After the numerical model validation using experimental data, simulations was carried over different operating conditions in terms of angle, heat flux on the collector, tank size and water inlet temperature. The analytical approach is divided into: irradiance model, tube model and tank model. The irradiance model determines the irradiance distribution of solar radiation along the circumference of the tube. Part of this radiation is absorbed by the collector and transferred to water, this amount is determined with the tube model, using the thermal resistance method. The tank model describes the thermal behavior of inside water, both in heating and in cooling, analyzing energy interaction with the collector and the external environment. The development of the tube model involves the assessment of the mass flow rate between the tube and the tank, furthermore the convection heat transfer coefficient inside the tube must be determined. These variables are determined from a correlation for the Reynolds number, which was obtained with evaluation results by CFD. Proposed Reynolds number is a function of the Nusselt, Prandtl and Grashof numbers. The correlation presented a good agreement with the numerical results. Using the experimental test bench the water temperature was measured into the tank over a few days. For the same experiment conditions, the average temperature of the water into the tank was estimated by results of integration of irradiance, tube and tank models. The difference between the experimental and theoretical results was 4.8% for the accumulated energy.
|
107 |
Estudo da formação de gelo durante o armazenamento a granel de vegetais congeladosUrquiola Mujica, Ana January 2018 (has links)
Este trabalho propõe um modelo de transferência de calor e massa para prever a formação de gelo em um container preenchido com legumes congelados. O problema físico é modelado como um meio poroso composto pelo próprio produto e o ar em seu entorno. O regime de convecção natural é assumido dentro do container, o qual promove o transporte de massa. Como uma primeira validação, o modelo é simulado considerando diferentes temperaturas de ar externo, causadas por flutuações da vizinhança. Resultados para quatro ciclos de temperaturas foram comparados, variando separadamente a temperatura média do ar, amplitude e frequência de oscilação. De modo geral, é observado que a temperatura do produto se comporta assim como era esperado e este resultado é diretamente associado à formação de gelo dentro do container. A formação de gelo cresce com uma maior amplitude de oscilação, porém decresce com um aumento na frequência e na temperatura média. Os parâmetros do modelo foram obtidos para dois diferentes produtos: fatias de cenouras congeladas e vagens congeladas, ambos em meio ao ar. As definições de parâmetros são oriundas de revisão bibliográfica, medições experimentais e simulações numéricas. Os parâmetros encontrados para a caracterização desses meios porosos foram similares para ambos os produtos, mesmo eles possuindo diferentes geometrias. A validação experimental foi feita para as fatias de cenoura considerando dois ciclos de temperatura O modelo numérico é capaz de prever o campo de velocidades do ar, as temperaturas do produto e a formação de gelo local. Os resultados foram validados em relação a um grupo independente de resultados numéricos, tal comparação apresentou uma boa concordância. A circulação de ar encontrada é, de fato, devido à convecção natural. O comportamento da temperatura dos produtos simulados concorda com os valores medidos e os valores de temperaturas diferem por menos de 12%. Com respeito à formação de gelo, o modelo é capaz de prevê-la corretamente nas regiões mais suscetíveis a este fenômeno. Porém, a quantidade de gelo formado prevista pelo modelo (1,56 g/semana) é menor do que a experimental (4,67 g/semana), apesar de serem de mesma ordem de magnitude. O efeito de cada parâmetro no modelo é estudado visando detectar maneiras de aprimorar o modelo. Foi encontrado que os parâmetros mais importantes para a formação de gelo total são a difusividade de massa efetiva e o coeficiente de transferência de calor convectivo dentro do container. Ajustando estes parâmetros duas vezes foi possível encontrar resultados melhores com respeito à formação de gelo (3,09 g/semana). / A model of heat and mass transfer is proposed in order to predict frost formation into a closed container filled with frozen vegetables. The physical problem is modeled as a macroporous media composed by the product itself and the surrounding air. Natural convection air flow is assumed into the container, who promotes water mass transport. As a first validation, the model is simulated for several exterior air temperatures, under environmental fluctuations (boundary conditions). Results of four temperature cycles were compared, varying average air temperature, amplitude and frequency of oscillation, one by one. As a general result, it is observed that the product temperature behavior is as expected, and it is directly associated with frost formation into the container. Frost formation increases with large amplitude of oscillation, but decreases with higher frequencies and higher mean temperatures. Model parameters were obtained for two assembling: frozen slices of carrots and air, and frozen extra thin green beans and air. Parameter definition and evaluation combines literature review, measurements and numerical simulation. In general, parameters which characterize these porous media were similar for both products, even though they display different geometries. The experimental validation is performed for carrot slices with two temperature cycles The numerical model is able to predict air velocity field, air and product temperatures, and local frost formation. Results are validated in respect to a set of independent experimental results that shown a good agreement. Air flow circulation is as expected due to natural convection. Product temperature simulated behavior agrees with measurements, and temperature values differ by less than 12%. Respect to frost formation predictions, the model predicts correctly the most susceptible regions to frost formation. However, the quantity of frost formed predicted by the model (1.56 g/ week)is lower than the experimental one (4.67g/week), despite being of the same order of magnitude. The effect of each parameter in the model is study in order to detect how to improve the model. The most important parameters affecting total frost formation are effective mass diffusivity and convective heat coefficient into the storage container. Adjusting these parameters to twice, better results in terms of frost formation could be obtained (3.09 g/ week).
|
108 |
Analise teorica e experimental da tranferencia de calor em placas de circuito impresso formando canais verticais abertos / Theoretical and experimental analysis of the heat transfer in printed circuit boards forming open vertical channelsAvelar, Ana Cristina 22 July 2018 (has links)
Orientador: Marcelo Moreira Ganzarolli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-22T20:18:14Z (GMT). No. of bitstreams: 1
Avelar_AnaCristina_M.pdf: 5757345 bytes, checksum: ab66436b252ec7b8b48d4756dd9e7f42 (MD5)
Previous issue date: 1997 / Resumo: Os constantes avanços tecnológicos em eletrônica e informática tem tornado os sistemas eletrônicos cada vez mais compactos, aumentando-se a quantidade de calor a ser removida dos componentes e placas de circuito impresso. Por este motivo, atualmente são exigidos sistemas de dissipação de calor altamente eficientes. Este estudo analisa teórica e experimentalmente a transferência de calor em canais verticais formados por placas de circuito impresso dispostas paralelamente, resfriadas por convecção natural e propõe uma modelagem, baseada em relações existentes na literatura, que busca prever a distribuição de temperaturas em pontos significativos nos canais e placas em função da potência dissipada e da distância entre as placas. Este estudo visa também analisar os efeitos do aquecimento não-uniforme das placas que formam o canal. Na simulação teórica, devido à pequena espessura da placa o gradiente de temperatura ao longo da espessura da mesma foi desprezado e resolveu-se numericamente a equação de transferência de calor em coordenadas cartesianas bidimensionais e em regime permanente. Equacionou-se balanços de energia para os componentes e para o ar no canal e o problema foi resolvido numericamente através de um programa computacional. As placas de circuito impresso utilizadas nos testes experimentais, concebidas exclusivamente para fins de estudos térmicos, possuem uma base de epóxi com 25 resistores discretamente distribuídos sobre sua superfície de 200x164mm. Realizou-se testes com aquecimento uniforme e não-uniforme, variando-se a potência por componentes nas placas. Variou-se também as potências por placas e as distâncias entre as mesmas. Testou-se as potências de 2, 4,6 e 8 W e as distâncias entre placas de 12,24, e 48mm. Verificou-se boa concordância entre os resultados numéricos e experimentais, principalmente para a menor distância entre placas, 12 mm, onde a diferença entre os resultados teóricos e experimentais foi muito pequena / Abstract: The constant technological advances in electronics and computations have made the electronic system increasingly more compact, thus increasing the amount of heat to be removed ITomthe components and printed circuit boards. For this reason, highly efficient system of heat removal are presently required. This study analyses both theoretically and experimentallyheat transfer in an array of vertical parallel printed circuit boards, cooled off by natural convection and proposes a modeling, based on correlation found in literature which tries to predict temperature distribution in significant places in the channels and boards as regards dissipated power and distance among boards. This study also aims at analyzing nonuniform heating effets of the channel made boards. In the theoritical simulation, due to the board' s small thickness, the temperature gradient across the board has been neglected, and the equation of heat transfer in two-dimensional Cartesian was numericallysolved, and on a steady state. Energy balances for the componentes were formulated, and the problem was numerically solved by a computer programo The printed circuit boards used in the experimental tests, manufactured speciallyfor heat trasnfer studies have an epoxy basis with 25 resistors discretely distributed on 200 x 164 mm. Uniform and non-uniform heating tests were performed, thus a variation of power and distance among them had a variation. The 2, 4, 6 and 8 W power and distance among 12, 24 and 48 mm boards were tested. Good agreements between numerical and experimentalresults were observed, mainlyfor the smaller distance among boards, 12 mm, the differencesbetween the theoretical and experimentalresults were small / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
|
109 |
Análise numérica da dinâmica do escoamento em circuitos de circulação natural / Numerical analysis of the fluid dynamics in a natural circulation loopANGELO, GABRIEL 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:20Z (GMT). No. of bitstreams: 0 / Circuitos de convecção natural ou sistemas de circulação natural são empregados em diversas áreas da engenharia. Reatores nucleares refrigerados a água utilizam circuitos de circulação natural como método passivo de seguranca. Em situações críticas, sem qualquer controle externo, o sistema permanece em segurança por suas próprias características de funcionamento (intrinsecamente seguro). O trabalho proposto consiste em estudar numericamente o circuito de circulação natural de água, localizado no Instituto de Pesquisas Energéticas e Nucleares / Comissão Nacional de Energia Nuclear em São Paulo, por meio do uso de modelos matemáticos, objetivando determinar o padrão do escoamento em condições sem mudança de fase líquido-vapor. A comparação dos resultados de temperatura obtidos por cada um dos modelos de turbulência aos pontos instrumentados no circuito experimental, na condição transitória, revelou desvios significativos nas respostas do modelo de zero equação. Desvios intermediário foram observados nos modelos de transporte da viscosidade turbulenta (EVTE), k - ω, SST e SSG e resultados melhores foram vericados nos modelos k - ε e DES (com significativa superioridade do primeiro modelo). / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
110 |
Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre / Establishment a primary standard system for low energy X-rays using a free air ionization chamberSILVA, NATALIA F. da 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:43:46Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:43:46Z (GMT). No. of bitstreams: 0 / Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0427 seconds