Spelling suggestions: "subject:"[een] RADIATION DETECTORS"" "subject:"[enn] RADIATION DETECTORS""
121 |
Padronização de feixes e metodologia dosimétrica em tomografia computadorizadaMAIA, ANA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:51Z (GMT). No. of bitstreams: 1
10890.pdf: 10562798 bytes, checksum: 063bd7e321751780a6d96cafecfe45bc (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:01/06837-2
|
122 |
Determinação do fator de pico de potência utilizando barras de controle, detectores ex-core e redes neuraisSOUZA, ROSE M.G. do P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:44Z (GMT). No. of bitstreams: 1
10895.pdf: 9491478 bytes, checksum: a17089904688d31b0c3d8e9056a263b2 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
123 |
Sobre a técnica de Rod Drop em medidas de reatividade integral em bancos de controle e segurança de reatores nucleares / About the technique of Rod Drop in measures of rod worth in security and control rods of nuclear reactorsSTEFANI, GIOVANNI L. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:23Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta um estudo sobre o efeito de sombreamento em detectores de nêutrons, quando estes são utilizados em medidas de reatividade com a técnica de rod drop. O sombreamento pode ser entendido como uma mudança na eciência dos detectores, quando esta é dada em nêutrons detectados/ssão ocorrida no reator, sendo mais evidente nos detectores mais próximos ao banco sendo inserido. O método de análise, fundamentalmente teórica, baseou-se em simulações do reator IPEN/MB-01 utilizando o código CITATION e o programa MCNP. Em ambos os casos, os resultados são estáticos, mostrando os uxos neutrônicos apenas em duas situações: antes da inserção do banco, e após sua inserção. A reatividade, neste caso, é obtida utilizandose a expressão derivada da técnica de source jerk. Em adição ao estudo teórico, os dados de um experimento de rod drop realizado no reator IPEN/MB-01 também foram utilizados. Neste caso, a reatividade foi obtida com o método de cinética inversa, já que os dados experimentais são constituídos de valores que variam no tempo. Em todos os casos, fatores de correção para o efeito de sombreamento são propostos. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
124 |
Modelo para determinacao da absorcao de substancias radioativas .Aplicacao em radiodosimetria e nutricaoMESQUITA, CARLOS H. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:08Z (GMT). No. of bitstreams: 1
04227.pdf: 2788884 bytes, checksum: 6ec206a76d3d65dff926c39d252535e5 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
125 |
Câmara de ionização aplicada a medidas de altas taxas de doseRODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Irradiadores comerciais de grande porte são projetados para processarem grandes quantidades de produtos com altas doses, por exposição à radiação gama. A irradiação em escala industrial é efetuada de forma dinâmica, em que os produtos percorrem um caminho em torno de uma fonte de radiação, geralmente de 60Co, cuja atividade é da ordem de TBq a PBq (kCi a MCi). A dose será diretamente proporcional ao tempo transcorrido pelo material para percorrer este trajeto em torno da fonte. Entretanto, em algumas situações, principalmente para pesquisas ou processos de validação de clientes seguindo a norma ISO 11137, se faz necessário irradiar pequenas amostras com doses fracionadas na posição de irradiação estática. Nesta posição as amostras são colocadas dentro da sala de irradiação a uma distância fixa da fonte e as doses recebidas são determinadas utilizando-se dosímetros. Portanto, a dose somente será conhecida depois da irradiação, pela leitura dos mesmos. Entretanto, em irradiadores industriais, diferentes tipos de produtos com diferentes densidades atravessam o caminho entre a fonte e a posição de irradiação estática, onde estão as amostras. Conseqüentemente, a taxa de dose variará dependendo da densidade do produto, que está sendo irradiado dinamicamente. Uma metodologia adequada seria monitorar a dose recebida pelas amostras em tempo real, medindo a dose por meio de um detector de radiação, com uma melhor precisão e exatidão. Neste trabalho foi desenvolvida uma câmara de ionização cilíndrica de 0.9 cm3, para monitorar as altas doses recebidas por amostras em tempo real, na posição de irradiação estática de um irradiador gama de 60Co. Os gases de nitrogênio e de argônio a pressão de 10exp5 Pa (1 bar) foram utilizados para preencherem a câmara de ionização e determinar uma configuração de trabalho apropriada, para o detector ser utilizado em medidas de altas doses. Cabos de isolação mineral foram soldados diretamente ao corpo da câmara de ionização, para a transmissão do sinal gerado pelo detector até a eletrônica associada, distante cerca de 20 m. O sinal obtido foi cerca de 100 vezes maior do que o ruído de fundo. Este sistema dosimétrico foi testado em um irradiador gama de categoria I e na posição de irradiação estática de um irradiador de grande porte, em que diferentes taxas de dose foram obtidas utilizando materiais absorvedores. Foi encontrada uma boa linearidade do detector entre a dose e a carga, independentemente das diferentes taxas de dose. As incertezas de todas as curvas ficaram abaixo dos +/- 5 %, valor de incerteza máxima recomendada para um sistema dosimétrico de rotina. A câmara de ionização desenvolvida se mostrou adequada para ser utilizada como um dosímetro em tempo real, independente da degradação do espectro causada pela absorção dos fótons da fonte de 60Co, pelo material em irradiação dinâmica. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
126 |
Estudo de incertezas no monitoramento in vivo utilizando a tecnica de Monte CarloVENTURINI, LUZIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 1
09672.pdf: 6449551 bytes, checksum: fc741e642f1069dc9671f312a9c4532b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
127 |
Obtenção de reatividade subcrítica por meio de medidas de APSD e CPSD utilizando detectores modo pulso no reator IPEN/MB-01 / Obtainment of subcritical reactivity by mean of measurement of APSD and CPSD employing pulse mode detectors in the IPEN/MB-01 reactorLEE, SEUNG M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:07Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho apresenta uma nova abordagem experimental para determinar a reatividade de sistemas subcríticos. O método a ser apresentado utiliza o modelo da cinética subcrítica desenvolvido por Gandini e Salvatores e baseia-se apenas em grandezas medidas, tais como a taxa de contagem no detector, e nos parâmetros que surgem do ajuste dos mínimos quadrados APSD (Auto Power Spectral Density) e CPSD (Cross Power Spectral Density), não sendo necessário lidar com as quantidades de maior complexidade como a eficiência de detector. A única hipótese feita neste método foi que a fração efetiva de nêutrons atrasados e o tempo de geração de nêutrons prontos fossem independentes do nível de subcriticalidade do sistema. O método proposto foi aplicado nas medidas de reatividade de várias configurações subcríticas do reator IPEN/MB-01. Foram realizadas medidas da APSD e CPSD em diversos graus de subcriticalidade (até em torno de -7000 pcm). Nos dados das densidades espectrais foram feitos ajustes por meio do método de mínimos quadrados para obter a constante de decaimento pronto (α) e outras grandezas. Com a finalide de melhorar as estatísticas de contagem de nêutrons, fonte externa de nêutrons de Am-Be foi instalada próximo ao núcleo, além da fonte de partida. O método experimental proposto mostra claramente que, a teoria da cinética pontual clássica não descreve a reatividade medida. Em vez disso, a reatividade inferida a partir do modelo da cinética pontual clássica é próxima, em seus valores absolutos, ao índice de subcriticalidade (ζ) para um determinado arranjo das fontes do experimeno. A concordância dos resultados obtidos por MCNP5 e GPT-TORT, ambos utilizando os dados nucleares da biblioteca ENDF/B-VII.0, com os resultados experimentais correspondentes são de boa qualidade. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:09/54838-0
|
128 |
Detectores gasosos de eletrodo resistivo: regime estacionario e transitorio de funcionamentoTOBIAS, CARMEN C.B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:20Z (GMT). No. of bitstreams: 1
09811.pdf: 7739701 bytes, checksum: 322f7fce8713f27550b470eff5575b73 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
129 |
Metodologia de aquisição de dados e análise por software, para sistemas de coincidências 4pß-? e sua aplicação na padronização de radionuclídeos, com ênfase em transições metaestáveis / Data acquisition with software analysis methodology for 4pß-? coincidence systems and application in radionuclide standardization, with emphasis on metastable transitionsBRANCACCIO, FRANCO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:33Z (GMT). No. of bitstreams: 0 / O Laboratório de Metrologia Nuclear (LMN) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) desenvolveu recentemente o Sistema de Coincidência por Software (SCS), para a digitalização e registro dos sinais de seus sistemas de coincidências 4πβ-γ utilizados na padronização de radionuclídeos. O sistema SCS possui quatro entradas analógicas independentes que possibilitam o registro simultâneo dos sinais de até quatro detectores (vias β e γ). A análise dos dados é realizada a posteriori, por software, incluindo discriminação de amplitudes, simulação do tempo-morto da medida e definição do tempo de resolução de coincidências. O software então instalado junto ao SCS estabeleceu a metodologia básica de análise, aplicável a radionuclídeos com decaimento simples, como o 60Co. O presente trabalho amplia a metodologia de análise de dados obtidos com o SCS, de modo a possibilitar o uso de detectores com alta resolução em energia (HPGe), para padronização de radionuclídeos com decaimentos mais complexos, com diferentes ramos de decaimento ou com transições metaestáveis. A expansão metodológica tem suporte na elaboração do programa de análise denominado Coincidence Analyzing Task (CAT). A seção de aplicação inclui as padronizações do 152Eu (diferentes ramos de decaimento) e do 67Ga (nível metaestável). A padronização do 152Eu utilizou uma amostra de uma comparação internacional promovida pelo BIPM (Bureau International des Poids et Mesures), podendo-se comparar a atividade obtida com o valores de laboratórios mundialmente reconhecidos, de modo a avaliar e validar a metodologia desenvolvida. Para o 67Ga, foram obtidas: a meia-vida do nível metaestável de 93 keV, por três diferentes técnicas de análise do conjunto de dados (βpronto-γatrasado-HPGe, βpronto-γatrasado-NaI e βpronto- βatrasado); as atividades de cinco amostras, normalizadas por Monte Carlo e as probabilidades de emissão gama por decaimento, para nove transições. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
130 |
Pesquisas propriedades e aplicacoes de detectores de faisca em problemas de fisica nuclear de energia atomicaGONCALVES, JOSEMARY A.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:06Z (GMT). No. of bitstreams: 1
02029.pdf: 4740189 bytes, checksum: ff05d787c5ab98b675cc36bbe2b0c062 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.0548 seconds