• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • 2
  • 1
  • Tagged with
  • 150
  • 150
  • 34
  • 33
  • 22
  • 20
  • 20
  • 20
  • 19
  • 19
  • 17
  • 17
  • 16
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Modelo para determinacao da absorcao de substancias radioativas .Aplicacao em radiodosimetria e nutricao

MESQUITA, CARLOS H. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:08Z (GMT). No. of bitstreams: 1 04227.pdf: 2788884 bytes, checksum: 6ec206a76d3d65dff926c39d252535e5 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
112

Câmara de ionização aplicada a medidas de altas taxas de dose

RODRIGUES JUNIOR, ARY de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:57Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
113

Estudo de incertezas no monitoramento in vivo utilizando a tecnica de Monte Carlo

VENTURINI, LUZIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 1 09672.pdf: 6449551 bytes, checksum: fc741e642f1069dc9671f312a9c4532b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
114

Obtenção de reatividade subcrítica por meio de medidas de APSD e CPSD utilizando detectores modo pulso no reator IPEN/MB-01 / Obtainment of subcritical reactivity by mean of measurement of APSD and CPSD employing pulse mode detectors in the IPEN/MB-01 reactor

LEE, SEUNG M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:07Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:09/54838-0
115

Detectores gasosos de eletrodo resistivo: regime estacionario e transitorio de funcionamento

TOBIAS, CARMEN C.B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:20Z (GMT). No. of bitstreams: 1 09811.pdf: 7739701 bytes, checksum: 322f7fce8713f27550b470eff5575b73 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
116

Metodologia de aquisição de dados e análise por software, para sistemas de coincidências 4pß-? e sua aplicação na padronização de radionuclídeos, com ênfase em transições metaestáveis / Data acquisition with software analysis methodology for 4pß-? coincidence systems and application in radionuclide standardization, with emphasis on metastable transitions

BRANCACCIO, FRANCO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:33Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
117

Pesquisas propriedades e aplicacoes de detectores de faisca em problemas de fisica nuclear de energia atomica

GONCALVES, JOSEMARY A.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:06Z (GMT). No. of bitstreams: 1 02029.pdf: 4740189 bytes, checksum: ff05d787c5ab98b675cc36bbe2b0c062 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
118

Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios X gerados no intervalo de 50 kV subp a 125 kV subp

NOGUEIRA, MARIA do S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:03Z (GMT). No. of bitstreams: 1 04674.pdf: 2960498 bytes, checksum: 31da12ce5904c3db2729e9982663d7fe (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
119

Desenvolvimento de sondas cirúrgicas radioguiadas com semicondutores de TlBr e com cristais cintiladores de CsI(Tl)

COSTA, FABIO E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:00Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
120

Análise das propriedades termoluminescentes e exoeletrônicas de dosímetros de CaSO4:Eu com adição de prata

Junot, Danilo Oliveira 25 February 2013 (has links)
The dosimetry of ionizing radiation is essential to procedures could be taken in order to maximize the beneficial effects that the use of such radiation can offer to society, as well as minimize damage from such radiation. As a result, different materials detectors have been proposed in the literature for use in personal and environmental dosimetry. Thermoluminescent detectors are widely used in these dosimetric procedures. The motivation of this work was to produce crystals of CaSO4 doped with unusual elements such as europium (Eu) and silver (Ag), including in the form of nanoparticles, prepared by an adaptation of the method developed by Yamashita (1971). The interest in the production of these materials was to investigate other methods of producing thermoluminescent materials. In the new growth route, the crystals were produced from calcium carbonate (CaCO3), by incorporating the dopants (Eu2O3 or Ag2O3) in a solution of sulfuric acid. Silver nanoparticles Ag(NP) were obtained through a synthesis route called polyol method, which is based on the reduction of Ag ions in a polyalcohol, in this case the ethylene glycol. The composites were obtained from the mixture of the base compound and glass or Teflon. The thermally stimulated exoeletronic emission of the new materials was investigated. Thermoluminescent characteristics as linearity, reproducibility, energy dependence, minimum detectable dose, fading and kinetics order were evaluated. The composites showed TL emission glow curves with a single peak centered around 200 ° C for samples containing Teflon and 230 ° C for samples with addition of glass. The new routes for the preparation of dosimeters were shown to be viable, being the dosimeter based on calcium sulfate doped with europium and silver nanoparticles (CaSO4:Eu,Ag(NP)), which provides the most intense TL emission between the preparations studied, being linear, reproducible, with low fading and low detection limit. / A dosimetria das radiações ionizantes é essencial para que procedimentos possam ser tomados com o objetivo de maximizar os efeitos benéficos que o uso dessas radiações pode oferecer à sociedade, assim como minimizar os danos decorrentes de tais radiações. Em decorrência disso, diferentes materiais detectores têm sido propostos na literatura para o emprego em dosimetria pessoal e ambiental. Detectores termoluminescentes têm larga utilização nesses procedimentos dosimétricos. A motivação deste trabalho foi produzir cristais de CaSO4 dopados com elementos não usuais como o európio (Eu) e a prata (Ag), inclusive na forma de nanopartículas, preparados por meio de uma adaptação do método desenvolvido por Yamashita (1971). O interesse na produção desses materiais foi o de investigar outras metodologias de produção de materiais termoluminescentes. Pela nova rota de crescimento, os cristais foram produzidos a partir do carbonato de cálcio (CaCO3), incorporando-se os dopantes (Eu2O3 ou Ag2O) numa solução de ácido sulfúrico. As nanopartículas de prata Ag(NP) foram obtidas através da rota de síntese chamada de método poliol, que se baseia na redução de cátions Ag em um poliálcool, neste caso o etileno glicol. Os compósitos foram obtidos a partir da mistura do composto base e da adição eletiva de vidro ou Teflon. A emissão exoeletrônica termicamente estimulada dos novos materiais produzidos foi investigada. Características termoluminescentes como linearidade, reprodutibilidade, dependência energética, dose mínima detectável, desvanecimento e ordem cinética foram avaliadas. Os compósitos apresentaram curvas de emissão TL com um único pico, centrado em torno de 200°C para as amostras contendo Teflon e 230°C para as amostras com adição de vidro. As novas rotas de preparação dos dosímetros termoluminescentes mostraram-se viáveis, sendo o dosímetro à base de sulfato de cálcio dopado com európio e nanopartículas de prata (CaSO4:Eu,Ag(NP)) o que apresenta a emissão TL mais intensa entre as preparações estudadas, sendo linear, reprodutível, com baixo desvanecimento e baixo limite inferior de detecção.

Page generated in 0.0262 seconds