• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 356
  • 344
  • 76
  • 51
  • 39
  • 14
  • 13
  • 13
  • 11
  • 11
  • 9
  • 9
  • 9
  • 8
  • 6
  • Tagged with
  • 1054
  • 196
  • 144
  • 143
  • 99
  • 80
  • 68
  • 68
  • 67
  • 64
  • 61
  • 60
  • 60
  • 60
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito de cargas compressivas oblíquas e da simulação de ciclos mastigatório sobre pilares para implantes cone morse / Effects of oblique compressive load and simulated chewing cycles on internal tapered implant-abutment connections

Moris, Izabela Cristina Mauricio 15 December 2011 (has links)
A literatura relata que a união osso/implante é extremamente confiável, porém limitações clínicas em relação à prótese ainda ocorrem. Recentemente foi proposto um pilar para implantes cone morse cujo desenho permite a escolha entre coroas cimentadas ou parafusadas, adicionalmente, este pilar também é apresentado em dois tamanhos, o convencional (ø 4,8 mm) e reduzido (ø 3,8 mm). O objetivo deste estudo foi avaliar a resistência à deformação dos pilares protéticos, a resistência de cimentação das coroas e os efeitos da simulação de ciclos mastigatórios sobre: adaptação marginal, perda de torque nos parafusos das coroas e perda de torque dos dois diferentes pilares. Para avaliar a resistência à deformação, 20 implantes/pilares com diâmetro de 4.8 e 3.8 foram submetidos à carga compressiva oblíqua. Para avaliar as outras situações, 40 implantes/pilares foram divididos nos seguintes grupos (N=10): G4.8P- pilar de 4.8 e coroas parafusadas; G4.8C-pilar de 4.8 e coroas cimentadas; G3.8P- pilar de 3.8 e coroas parafusadas; G3.8C- pilar de 3.8 e coroas cimentadas. Todas as coroas foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios e as coroas cimentadas foram submetidas ao teste de resistência à tração previamente ao ensaio. Os conjuntos foram submetidos a 300.000 ciclos de simulação de movimentos mastigatórios. A perda de torque das coroas parafusadas e de todos os pilares foi analisada antes a após o ensaio. Não houve diferenças significantes para a resistência à deformação entre os pilares; para a resistência de cimentação houve diferenças significantes entre os dois pilares (p≤0,05). Para a adaptação marginal houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre os grupos G3.8P (p=0,037) e G3.8C (p≤0,05); para a comparação da adaptação das coroas entre os pilares houve diferenças antes da simulação dos ciclos mastigatórios quando comparado os grupos 3.8C com 3.8P e antes e após da simulação quando comparado os grupos 4.8C com 4.8P, para as demais comparações não houve diferença. Quanto à perda de torque nos parafusos das coroas houve diferenças significantes antes e após a simulação dos ciclos mastigatórios para ambos os pilares, quanto às comparações entre os diferentes grupos antes e após a simulação de ciclos mastigatórios houve diferença apenas após (p=0,008) a simulação. Quanto à perda de torque para os pilares houve diferenças significantes apenas para o grupo 3.8C (p≤0,05) antes e após a simulação dos ciclos mastigatórios. Considerando as limitações deste estudo, conclui-se que em relação à resistência à deformação os pilares apresentaram valores próximos; quanto a retenção das coroas, cimentadas e parafusadas, os pilares de 4.8 foram estatisticamente superiores aos pilares de 3.8; a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das coroas e em relação a perda de torque dos pilares não foram encontradas diferenças estatísticas. / Reports in the literature have stated that the bone/implant interface is extremely reliable. However, clinical limitations in relation to the prosthesis still occur. A Morse taper implant-abutment design that allows choosing between cemented or screwed crowns has been recently proposed. The abutment is presented in two different diameter sizes (conventional (ø 4.8 mm) and narrow (ø 3.8 mm). The aim of this study was to evaluate the resistance to deformation of the implant/abutment interface, the tensile strength of the cemented crowns and the effects of simulated chewing cycles on: marginal fit, crown-screw torque loss and torque loss of the two different abutments. To evaluate the resistance to deformation, 20 abutments with diameter of 4.8 and 3.8 were subjected to compressive oblique load. To evaluate the other situations, 40 implants/abutments were divided into the following groups (N = 10): G4.8P-abutment 4.8 with screwed crowns; G4.8C-abutment 4.8 with cemented crowns; G3.8P abutment 3.8 with screwed crows; G3.8C-abutment 3.8 with cemented crowns. All crowns were evaluated for marginal fit before and after simulation of the chewing cycles. The cemented crowns were subjected to tensile strength test before the simulated chewing cycles. The specimens were subjected to 300,000 cycles that simulated the chewing movements. The torque loss of the screwed crowns and all abutments were analyzed before and after the cycling tests. No significant differences were found for the deformation resistance between the abutments. No significant differences were found in the tensile strength of the cemented crowns between the two abutments (p≤0.05). The marginal fit of the crowns found no significant differences before and after the simulation of the chewing cycles between groups G3.8P (p = 0.037) and G3.8C (p≤0.05). No differences were found in crown misfit between the abutments before simulating the chewing cycles when compared between groups 3.8C 3.8P. No differences were found between groups 4.8C and 4.8P before and after the chewing simulation. Torque loss of the screwed crowns was not significantly different before and after the simulation of the chewing cycles for both abutments. Comparisons between the different groups before and after simulation found significant differences after the simulation of the chewing cycles (p = 0.008). Group 3.8C was the only group that presented significant differences (p≤0.05) before and after the simulation cycles. Within the limitations of this study, it can be concluded that the resistance to deformation between both abutments was similar. Retention of cemented and screwed crowns was statistically higher for the 4.8 abutments when compared to the 3.8 abutments. The simulation of chewing cycles significantly influenced the marginal fit of the crowns. No differences statistically significant in torque loss were found between the two abutments.
42

Análise mecânica e da deformação da conexão de implantes de hexágono externo após a instalação com um novo tipo de montador /

Oliani, Marcelo Gallo. January 2019 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Tarcísio José de Arruda Paes Junior / Banca: Fernanda de Cassia Papaiz Gonçalves / Banca: Rodrigo Máximo de Araújo / Banca: Jean Soares Miranda / Resumo: A sobrecarga do hexágono durante a inserção dos implantes dentários de hexágono externo pode gerar danos irreversíveis ao mesmo ocasionando problemas futuros na reabilitação. Sendo assim, esse trabalho teve por objetivo avaliar a deformação e resistência ao contra-torque dos hexágonos com o uso de um montador modificado proposto pelo autor para inserção dos implantes tipo hexágono externo (HE) tendo como hipótese de que o montador modificado apresente resultados diferentes do montador padrão. Para isso, 44 implantes foram divididos em dois grupos, controle (montador normal MN; n=12) e o teste (montador modificado MM; n=12), e foram submetidos ao teste de torção seguindo os parâmetros da norma ISO 13498:2013. Em seguida, a deformação dos hexágonos e possíveis deformações causadas às roscas internas dos implantes foram analisadas, respectivamente, de forma qualitativa por meio de microscopia eletrônica de varredura. Já para o teste de fadiga, controle (MN; n=10) e teste (MM; n=10), os parâmetros utilizados foram da norma ISO 14801:2007. Ao final de 1,2 x 106 (4Hz) ciclos, o valor de destorque dos pilares foi registrado. A desadaptação da junta pilar/implante foi avaliada qualitativamente por meio da microscopia MEV. Como resultados pudemos observar maior manutenção da estrutura da conexão pelo grupo MM comparado ao grupo MN, sugerindo-se que o grupo MM apresentaram comportamento mais seguro e previsível quando comparado ao grupo MN / Abstract: Hexagon overload during the insertion of external hexagon dental implants can lead to irreversible damage, leading to future problems in rehabilitation. Thus, this study aimed to evaluate the deformation and reverse torque resistance of hexagons with the use of a modified mount proposed by the author for insertion of external hexagon (HE) implants with the hypothesis that the modified mount presents different results compared to the default assembler. For this, 44 implants were divided into two groups, control (normal mount MN; n = 12) and the test (modified mount MM; n = 12), and were submitted to torsion testing following the parameters of ISO 13498: 2013. Then, the deformation of the hexagons and possible deformations caused to the internal threads of the implants were analyzed qualitatively, respectively by scanning electron microscopy. For the fatigue test, control (MN; n = 10) and test (MM; n = 10), the parameters used were from ISO 14801: 2007. At the end of 1.2 x 106 (4Hz) cycles, the abutment value of the abutments was recorded. Abutment of the abutment / implant joint was qualitatively evaluated by SEM microscopy. As a result we could observe a better maintenance of the connection structure by the MM group compared to the MN group, suggesting that the MM group presented a safer and more predictable behavior when compared to the MN group / Doutor
43

Le fil orthodontique hybride et son influence sur les mouvements de troisième ordre : une étude comparative

Yacoub, Serge January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
44

Avaliação das características geométricas, dimensionais, de flexibilidade e resistência torcional dos instrumentos de NiTi do Sistema Pro Taper Universal para retratamento /

Hussne, Renata Pardini. January 2009 (has links)
Resumo: O presente trabalho se propôs a avaliar as características geométricas e dimensionais dos instrumentos de NiTi do sistema ProTaper Universal Retratamento bem como sua flexibilidade e resistência torcional. Um total de 102 instrumentos foram empregados neste estudo. Inicialmente, 12 instrumentos de cada formato foram submetidos a uma caracterização geométrica e dimensional por microscopia óptica. Foram avaliados os parâmetros ângulo, comprimento e diâmetro de ponta, comprimento de cada pitch ao longo das hastes e diâmetro do instrumento a cada milímetro da ponta. Após isto, todos os instrumentos foram aleatoriamente divididos em 3 grupos distintos: Grupo 1 contendo 36 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 12 unidades de cada formato para os ensaios de torção; Grupo 2 contendo 36 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 12 unidades de cada formato para os ensaios de flexibilidade; Grupo 3 contendo 30 instrumentos ProTaper Universal Retratamento D1, D2 e D3, sendo 10 unidades de cada formato para os ensaios de torção após estes instrumentos terem sido usados na desobturação de 15 canais radiculares. Tais ensaios de torção e flexibilidade foram executados de acordo com a especificação ISO 3630-1 em um dispositivo de bancada para testes utilizando um programa para aquisição e processamento dos dados especialmente desenvolvido para este fim. Os valores para torque máximo, deflexão angular até a fratura e momento de dobramento foram analisados estatisticamente pelo teste t de Student. Os resultados demonstraram que os instrumentos do Sistema ProTaper Universal Retratamento apresentaram boa padronização geométrica e características de superfície aceitáveis, embora tenham sido verificadas diferenças geométricas e dimensionais entre os instrumentos do sistema. O torque máximo e o momento de dobramento a 45o foram... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study has proposed to evaluate the geometric and dimensional features of NiTi ProTaper Universal Retreatment System's instruments as well as their flexibility and torsional resistance. It was used a total amount of 102 instruments. At the beginning, 12 instruments of each size were analyzed dimensional and geometrically by optical microscopy under parameters of angle, length and tip diameter, pitch's length along the blade and instrument's diameter from tip until the end of the active part. After that, all the instruments were randomly divided into 3 different groups: Group 1 having 36 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),12 samples from each size, to be submitted to torsion test; Group 2 having 36 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),12 samples from each size, to be submitted to bending test; Group 3 having 30 ProTaper Universal Retreatment instruments inside (D1, D2 and D3),10 samples from each size, to be submitted to torsion test after being used in 15 root canal unfilling. These torsion and bending tests were performed using a bench test device connected with a software to acquire and process data specially developed to this purpose, according to ISO 3630-1. Maximum torque, angular deflection until fracture and bending moment values were statistically analysed using Student's t test. The results showed that ProTaper Universal Retreatment System's instruments presented good geometric standardization and acceptable surface features, however differences were detected among the instruments. The maximum torque and the bending moment at 45º were higher for instruments with larger diameters (D1>D2>D3), even though angular deflection didn't show this same relationship. Besides, the new instruments showed a higher maximum torque value when compared to the ones who were used in 15 root canals unfilling. / Orientador: Fábio Luiz Camargo Villela Berbert / Coorientador: Maria Guiomar Azevedo Bahia / Banca: Celso Kenji Nishiyama / Banca: Carlos Eduardo da Silveira Bueno / Banca: Mário Tanomaru Filho / Banca: Idomeo Bonetti Filho / Doutor
45

Análise do exercício de agachamento utilizando o método de Kane

Nogueira, Rodrigo Pereira [UNESP] 14 December 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-12-14Bitstream added on 2014-06-13T20:18:21Z : No. of bitstreams: 1 nogueira_rp_me_guara.pdf: 931314 bytes, checksum: 6d876c670577d2caa4189e93a9106a4f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O sedentarismo é crescente na população mundial e com ele cresce a incidência das doenças crônicas degenerativas. Em contrapartida têm-se os exercícios físicos que são recomendados para a prevenção, tratamento e reabilitação dessas doenças. A musculação é um desses exercícios e sua prática cresce cada dia mais. Dentre todos os exercícios que podem ser realizados na musculação, está o agachamento, que é muito utilizado para fortalecer a musculatura dos membros inferiores, porém a execução errônea do mesmo pode acarretar lesões irreversíveis ao praticante. Atualmente são utilizados conceitos biomecânicos para estudar e compreender os esforços mecânicos acerca do agachamento visando a proteção do sistema musculoesquelético. A presente dissertação tem como objetivo aplicar o método de Kane a um modelo de corpo humano buscando analisar os torques articulares e as forças nos tendões musculares dos membros inferiores durante o exercício de agachamento. A instrumentação contou com modelo biomecânico bidimensional (2D) desenvolvido a partir do método de Kane, que consiste na análise do sistema multicorpo através de conceitos de velocidades, forças ativas e inércia generalizadas. Os resultados de pico de torque encontrados foram de 36,9 N.m no tornozelo, 51 N.m no joelho e 119,1 N.m no quadril. Os resultados de picos de força nos tendões musculares foram de 1290 N no gastrocnêmio, 723 N no quadríceps e 730 N nos isquiotibiais. O método se mostrou eficaz ao calcular os esforços mecânicos nas articulações de membros inferiores, porém são necessários mais estudos englobando um maior número de variáveis para completa elucidação do assunto. / Physical inactivity is increasing in the world population and with it the incidence of chronic degenerative diseases grows. In contrast, there are the exercises that are recommended for the prevention, treatment and rehabilitation of these diseases. Strength training is one of these exercises and their practice grows every day. Among all the exercises can be performed, is the squat, which is widely used to strengthen the muscles of the lower limbs, however the erroneous execution can result in irreversible damage. Biomechanical concepts are currently used to study and understand the mechanical stress on the squat in order to protect the musculoskeletal system. This study aims to apply the Kane’s method to a human body model seeking to analyze the joint torques and muscle forces in the tendons of the lower limbs during the squat. The instrumentation featured biomechanical model with two-dimensional (2D) developed from Kane’s method, which consists of analysis of multibody systems using concepts of generalized speed, generalized active forces and generalized inertia. The results of peak torque were 36.9 N.m in the ankle, 51 N.m in the knee and 119.1 N.m in the hip. The results of peak strength in the muscle tendons were 1290 N in the gastrocnemius, 723 N in the quadriceps to 730 N in the hamstrings. The method was reliable to calculate the mechanical stress on the joints of the lower limbs, but more studies are needed covering a larger number of variables to complete elucidation of this subject.
46

Efeito de cargas compressivas oblíquas e da simulação de ciclos mastigatório sobre pilares para implantes cone morse / Effects of oblique compressive load and simulated chewing cycles on internal tapered implant-abutment connections

Izabela Cristina Mauricio Moris 15 December 2011 (has links)
A literatura relata que a união osso/implante é extremamente confiável, porém limitações clínicas em relação à prótese ainda ocorrem. Recentemente foi proposto um pilar para implantes cone morse cujo desenho permite a escolha entre coroas cimentadas ou parafusadas, adicionalmente, este pilar também é apresentado em dois tamanhos, o convencional (ø 4,8 mm) e reduzido (ø 3,8 mm). O objetivo deste estudo foi avaliar a resistência à deformação dos pilares protéticos, a resistência de cimentação das coroas e os efeitos da simulação de ciclos mastigatórios sobre: adaptação marginal, perda de torque nos parafusos das coroas e perda de torque dos dois diferentes pilares. Para avaliar a resistência à deformação, 20 implantes/pilares com diâmetro de 4.8 e 3.8 foram submetidos à carga compressiva oblíqua. Para avaliar as outras situações, 40 implantes/pilares foram divididos nos seguintes grupos (N=10): G4.8P- pilar de 4.8 e coroas parafusadas; G4.8C-pilar de 4.8 e coroas cimentadas; G3.8P- pilar de 3.8 e coroas parafusadas; G3.8C- pilar de 3.8 e coroas cimentadas. Todas as coroas foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios e as coroas cimentadas foram submetidas ao teste de resistência à tração previamente ao ensaio. Os conjuntos foram submetidos a 300.000 ciclos de simulação de movimentos mastigatórios. A perda de torque das coroas parafusadas e de todos os pilares foi analisada antes a após o ensaio. Não houve diferenças significantes para a resistência à deformação entre os pilares; para a resistência de cimentação houve diferenças significantes entre os dois pilares (p≤0,05). Para a adaptação marginal houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre os grupos G3.8P (p=0,037) e G3.8C (p≤0,05); para a comparação da adaptação das coroas entre os pilares houve diferenças antes da simulação dos ciclos mastigatórios quando comparado os grupos 3.8C com 3.8P e antes e após da simulação quando comparado os grupos 4.8C com 4.8P, para as demais comparações não houve diferença. Quanto à perda de torque nos parafusos das coroas houve diferenças significantes antes e após a simulação dos ciclos mastigatórios para ambos os pilares, quanto às comparações entre os diferentes grupos antes e após a simulação de ciclos mastigatórios houve diferença apenas após (p=0,008) a simulação. Quanto à perda de torque para os pilares houve diferenças significantes apenas para o grupo 3.8C (p≤0,05) antes e após a simulação dos ciclos mastigatórios. Considerando as limitações deste estudo, conclui-se que em relação à resistência à deformação os pilares apresentaram valores próximos; quanto a retenção das coroas, cimentadas e parafusadas, os pilares de 4.8 foram estatisticamente superiores aos pilares de 3.8; a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das coroas e em relação a perda de torque dos pilares não foram encontradas diferenças estatísticas. / Reports in the literature have stated that the bone/implant interface is extremely reliable. However, clinical limitations in relation to the prosthesis still occur. A Morse taper implant-abutment design that allows choosing between cemented or screwed crowns has been recently proposed. The abutment is presented in two different diameter sizes (conventional (ø 4.8 mm) and narrow (ø 3.8 mm). The aim of this study was to evaluate the resistance to deformation of the implant/abutment interface, the tensile strength of the cemented crowns and the effects of simulated chewing cycles on: marginal fit, crown-screw torque loss and torque loss of the two different abutments. To evaluate the resistance to deformation, 20 abutments with diameter of 4.8 and 3.8 were subjected to compressive oblique load. To evaluate the other situations, 40 implants/abutments were divided into the following groups (N = 10): G4.8P-abutment 4.8 with screwed crowns; G4.8C-abutment 4.8 with cemented crowns; G3.8P abutment 3.8 with screwed crows; G3.8C-abutment 3.8 with cemented crowns. All crowns were evaluated for marginal fit before and after simulation of the chewing cycles. The cemented crowns were subjected to tensile strength test before the simulated chewing cycles. The specimens were subjected to 300,000 cycles that simulated the chewing movements. The torque loss of the screwed crowns and all abutments were analyzed before and after the cycling tests. No significant differences were found for the deformation resistance between the abutments. No significant differences were found in the tensile strength of the cemented crowns between the two abutments (p≤0.05). The marginal fit of the crowns found no significant differences before and after the simulation of the chewing cycles between groups G3.8P (p = 0.037) and G3.8C (p≤0.05). No differences were found in crown misfit between the abutments before simulating the chewing cycles when compared between groups 3.8C 3.8P. No differences were found between groups 4.8C and 4.8P before and after the chewing simulation. Torque loss of the screwed crowns was not significantly different before and after the simulation of the chewing cycles for both abutments. Comparisons between the different groups before and after simulation found significant differences after the simulation of the chewing cycles (p = 0.008). Group 3.8C was the only group that presented significant differences (p≤0.05) before and after the simulation cycles. Within the limitations of this study, it can be concluded that the resistance to deformation between both abutments was similar. Retention of cemented and screwed crowns was statistically higher for the 4.8 abutments when compared to the 3.8 abutments. The simulation of chewing cycles significantly influenced the marginal fit of the crowns. No differences statistically significant in torque loss were found between the two abutments.
47

Efeito do desajuste marginal, tipo de soldagem e material do parafuso sobre a força de destorque de parafusos protéticos e tensões induzidas aos pilares / Effect of marginal misfit, welding type and screw material on the strength of the detorque prosthetic screws and stress induced the abutments

Rodrigues, Sabrina Alessandra, 1986- 20 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Texto em português e inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T10:21:04Z (GMT). No. of bitstreams: 1 Rodrigues_SabrinaAlessandra_M.pdf: 1119923 bytes, checksum: 0658dc800fd1f207e56523b3a09bd2e2 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi analisar as tensões induzidas aos análogos de pilares protéticos, utilizando-se strain gauges; e avaliar a força de destorque de parafusos protéticos (ouro e titânio) em infraestruturas fundidas em titânio comercialmente puro (Ti cp), antes e após os procedimentos de soldagem laser e TIG (tungsten inert gas). Foram confeccionadas vinte infraestruturas fundidas em titânio comercialmente puro (Ti cp), simulando uma prótese fixa de três elementos; vinte modelos índex com análogos de pilares protéticos modificados para desenvolvimento da análise de tensão e vinte modelos índex com análogos de pilares protéticos convencionais para realização das soldagens e avaliação da força de destorque de parafusos protéticos. Os dois tipos de modelos índex foram confeccionados simulando desajuste marginal vertical de aproximadamente 200 'mi'm. A mensuração do nível de desajuste marginal vertical das infraestruturas foi realizada em microscópio de precisão, por meio do teste do parafuso único (antes e após a soldagem). As soldagens seguiram os seguintes parâmetros: Laser (370V/9ms), TIG (3:36A/2: 60 ms). As tensões induzidas nos análogos modificados de pilares protéticos foram avaliadas por análise extensométrica, utilizando-se strain gauges (antes e após as soldagens). O torque dos parafusos de ouro e titânio foi realizado utilizando-se a técnica de torque (10 N cm) e retorque (10 N cm), após 10 minutos. O destorque dos parafusos foi realizado após 10 minutos do retorque, utilizando-se torquímetro digital. Os resultados foram analisados estatisticamente (ANOVA/Tukey (?=0,05) e teste de correlação de Pearson). Observou-se redução dos níveis de desajuste marginal vertical das infraestruturas, após os procedimentos de soldagem (laser e TIG). Quanto aos níveis de tensão induzidos aos análogos de pilares protéticos pós-soldagem, foram menores para soldagem a laser quando comparados à TIG. Em relação ao destorque dos parafusos, após as soldagens, a força de destorque dos parafusos de ouro foi menor em relação a força de destorque dos parafusos de titânio, que aumentou após os procedimentos de soldagem. Não houve correlação entre desajuste marginal, tensão e força de destorque. Assim, conclui-se que o procedimento de soldagem a laser foi mais eficaz na melhora da adaptação das infraestruturas de três elementos implantossuportadas, quando comparado ao procedimento de soldagem a TIG; e que a os parafusos protéticos de titânio podem ser considerados mais estáveis que os parafusos protéticos de ouro quando torqueados em próteses que possuem satisfatória adaptação / Abstract: The aim of this study was to evaluate the stress induced to analogs of prosthetic abutment using strain gauges and to analyze the detorque strength of prosthetic screws (gold and titanium) of frameworks casted in commercially pure titanium (cp Ti) before and after laser and TIG (tungsten inert gas) welding procedures. Twenty frameworks were made simulating a three-element fixed prosthesis. Twenty index models with modified analogs of prosthetic abutments were obtained for stress analyses and twenty index models with conventional analogs of prosthetic abutments for welding (laser e TIG) and detorque analyses of the prosthetic screws. Both index models were made with 200 'mi'm vertical marginal misfit. An optic microscope was used to measure the vertical marginal misfit following the single-screw test protocol. The welding parameters were the following: laser welding (370V/9ms), TIG welding (3: 36A/2: 60ms). The stress induced on the analogs was evaluated through of the extensometric analysis using strain gauges (before and after welding). The torque of gold and titanium screws was performed with torque (10 Ncm) and retorque (10 Ncm) after 10 minutes. The detorque of the prosthetic screws was performed 10 minutes after the retorque using a digital torquemeter. The results were statistically analyzed (ANOVA/Tukey test (?=0.05)/ Pearson correlation test). A decrease in the levels of vertical marginal misfit was observed after the welding procedures (laser and TIG). Regarding the stress, after the welding procedures, stress levels were lower using laser welding than the TIG. The detorque values were lower for the gold screws than the titanium ones, which presented increased destorque values after welding procedures. There was no correlation between marginal misfit, stress and detorque strength. Thus, it can be concluded that the laser welding procedure was more effective for the improvement of adaptation of three-element implant-supported frameworks, when compared to TIG; and that titanium prosthetic screws can be considered more stable than the gold prosthetic screws when torqued in prostheses that present adaptation satisfactory / Mestrado / Protese Dental / Mestre em Clínica Odontológica
48

Forces, torques and accelerations involved in selected lifting and lowering techniques

Bhasin, Ramesh C January 2010 (has links)
Digitized by Kansas Correctional Industries
49

Torque expression and bracket deformation of the Orthos and OrthosTi orthodontic bracket

Lacoursiere, Ryan A. 11 1900 (has links)
Deformation of the orthodontic bracket upon wire engagement may result in torque dissipation within the bracket rather than transmission to the tooth and its supporting structures. The purpose of this study was: 1) quantify the amount of torque expression and 2) quantify any deformation as a result of such increasing torque expression. Digital image correlation is an accurate means of analyzing an orthodontic bracket's structural response to an applied moment of force created through archwire rotation in vitro. A sample of 30 Orthos and 30 OrthosTi brackets were tested with custom software using a novel application of digital image correlation. OrthosTi brackets produce significantly greater amounts of torque from 48 to 24 returning to a neutral position. Titanium brackets exhibit greater variance in torque expression but less variance in deformation. Orthos stainless steel brackets exhibit significantly greater amounts of bracket slot deformation in comparison to the OrthosTi. / Orthodontics
50

An Investigation of the Role of Dynamic Axial Torque on the Disc Herniation Mechanism

Marshall, Leigh January 2008 (has links)
Background: Disc herniations are common and have been demonstrated as one potential source of low back pain. To date epidemiological studies have found associations between lifting, lifting and twisting and twisting with increased risk in the development of disc herniations (Greenough and Fraser, 1994, Kelsey et al., 1984, Mundt et al., 1993). Subsequent, in vitro investigations were able to produce disc herniations through repeatitive flexion extension motions on cervical porcine functional spinal units (Callaghan and McGill, 2001). However, in vitro investigations on axial torque have drawn mixed conclusions and controversy remains on the role it plays with respect to disc herniations (Farfan et al., 1970, Adams et al., 1981). Therefore, the work in this thesis was to investigate the role of dynamic axial torque on the disc herniation mechanism. Methods: Porcine cervical spines were used as they are a good approximation to the human lumbar spine (Yingling et al., 1999). The study design involved repetitive flexion extension motions of the spinal units either preceded or followed by dynamic axial torque. During axial torque the spinal units were loaded to 17.5 Nm (standard deviation = 0.5 Nm) of dynamic axial torque for either 2000 or 4000 testing cycles. These spinal units were compared to spinal units that were loaded in repetitive flexion extension motions only and axial torque only. The spinal units were tested in a servohydraulic dynamic testing machine, combined with a custom jigs which allowed loading in flexion/extension, axial torque and compression. Plane film radiographs with contrast in the nucleus were obtained at regular intervals during and following the mechanical testing. Final dissection determined the disc injury patterns. Results and Discussion: Examination of the sectioned intervertebral discs indicated axial torque in combination with repetitive flexion extension motions, regardless of order, encouraged radial delamination. While, repetitive flexion extension motion alone encouraged posterior or posterolateral herniation patterns. Axial torque alone was unable to initiate a disc herniation. There was an increase in both rotation and stiffness of the intervertebral disc in response to repeated axial torque. There were no differences in rotation and stiffness between the groups. Both x-ray images and computed tomography scans were equally as good at identifying posterior or posterolateral herniations but were not good at detecting radial delamination.

Page generated in 0.0293 seconds