• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 1
  • Tagged with
  • 19
  • 19
  • 14
  • 14
  • 14
  • 13
  • 11
  • 10
  • 9
  • 9
  • 9
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] MODELING OF VOLTAGE CONTROL AND MULTIPLE SWING BUSES IN VOLTAGE STABILITY ASSESSMENT / [pt] MODELAGEM DO CONTROLE DE TENSÃO POR GERADORES E DE MÚLTIPLAS BARRAS SWING NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

MARCEL RENE VASCONCELOS DE CASTRO 14 February 2008 (has links)
[pt] O crescente aumento da complexidade dos sistemas elétricos de potência gera a necessidade de desenvolvimento de ferramentas que melhorem as condições de análise. O objetivo deste trabalho é aprimorar a ferramenta computacional de avaliação das condições de segurança (ou estabilidade) de tensão. No que diz respeito às barras associadas ao controle remoto de tensão por geração de potência reativa, são propostos novos modelos que representam mais adequadamente as condições operativas no momento do cálculo dos índices de segurança de tensão. Em relação à barra associada ao controle local de tensão por geração de potência reativa é proposta nova modelagem, aplicável tanto no problema de fluxo de potência, utilizando o método de Newton- Raphson, quanto no cálculo dos índices de segurança de tensão. Este modelo,mais robusto e flexível, inclui o controle de tensão local da barra no problema geral de fluxo de potência, formando um sistema de equações de ordem (2*número de barras+número de barras controladas localmente). Para o tratamento de múltiplas barras swing, é proposto um novo modelo, de novo para representar mais adequadamente as condições operativas. É aplicável tanto no problema básico de fluxo de potência, como no cálculo dos índices de segurança de tensão. O modelo proposto considera que apenas o ângulo de uma barra swing é especificado, com os ângulos das demais barras swing livres para variar. Testes numéricos com sistemas-teste (5 e 6 barras) comprovam a aplicabilidade e adequação dos modelos propostos comparando-os aos modelos usados atualmente. / [en] The crescent increase of the complexity of the electric power systems generates the need of development of tools to improve the analysis conditions. The objective of this work is to improve the computational tool of voltage security (stability) conditions assessment. As regards to the buses associated to remote voltage control by reactive power generation, new models that represent more appropriately the operatives conditions at the moment of the calculations of the voltage security indexes, are proposed. As regards to the bus associated to local voltage control by reactive power generation, it is proposed a new modeling, applicable as much in the power flow problem, using the Newton-Raphson method, as in the calculation of the voltage security indexes. This model, more robust and flexible, includes the local voltage control of the bus in the general power flow problem, constituting an equations system of order (2*number of system buses + number of buses with local voltage control). As regard to the multiples swing buses, it is proposed a new model, again to represents more appropriately the operatives conditions. It is applicable as much in the basic power flow problem, as in the calculation of the voltage security indexes. The proposed model considers that just one swing bus has your voltage angle specified and the others swing buses of the power system have your voltage angles free to vary.
2

[en] MODELLING SPECIAL EQUIPMENTS OF TRANSMISSION NETWORK FOR VOLTAGE SECURITY ASSESSMENT / [pt] MODELAGEM DE EQUIPAMENTOS ESPECIAIS DA REDE DE TRANSMISSÃO PARA AVALIAÇÃO DA SEGURANÇA DE TENSÃO

FAUSTO DE MARTTINS NETTO 19 May 2003 (has links)
[pt] Com o uso extremo das linhas de transmissão surgiram os problemas de estabilidade, ou mais apropriadamente, de segurança de tensão. A avaliação das condições de segurança de tensão é realizada pelo programa computacional ESTABTEN. Como os índices calculados são baseados em um ponto de operação do sistema e em um modelo linearizado das equações de fluxo de carga, assim como a função Fluxo de Carga do pacote computacional ANAREDE também o é, é importante que os modelos matemáticos do sistema, de equipamentos, de controles e de limites sejam compatíveis nos dois programas. Assim como o programa de fluxo de carga é continuamente estendido, o programa ESTABTEN deve continuar a ter sua capacidade estendida para atender as necessidades dos estudos.Estuda-se neste trabalho a modelagem em regime permanente de alguns equipamentos especiais da rede de transmissão e sua incorporação à função de avaliação da segurança de tensão. Os equipamentos contemplados foram: elos de corrente contínua (elo CC), compensadores estáticos de potência reativa (CER), esquemas de HVDC/CCC e linhas com compensação série controlada a tiristores (CSC). São mostrados exemplos numéricos que ilustram a necessidade de uma modelagem realista, na medida do possível. / [en] With the extreme use of the transmission lines, the voltage stability problem, or more properly, the voltage security problem has appeared. The voltage security condition assessment is achieved using the computational program ESTABTEN. The calculated indexes are based on a system operation point and on a linear model of load flow equations, likewise the ANAREDE load flow function. It is important that the mathematical models of systems, equipments, control devices and limits are compatible in both programs. As the load flow program is continually extended, the ESTABTEN program is to have its capability enhanced in order to attend the study requirements. This work is concerned with the steady-state modelling of some special equipments of the transmission network and its incorporation to the voltage security assessment function. The equipments considered were: direct current link (DC link), static VAR compensators (SVC), HVDC/CCC and lines with series controlled compensation (TSSC).Numerical examples are presented to illustrate the necessity of realistic modelling.
3

[en] TRANSMISSION CONGESTION ANALYSIS APPLIED ON VOLTAGE SECURITY REINFORCEMENT PROBLEM / [pt] ANÁLISE DO CONGESTIONAMENTO EM REDES DE TRANSMISSÃO APLICADA AO PROBLEMA DO REFORÇO DE SEGURANÇA DE TENSÃO

FELIPE ERNESTO LAMM PEREIRA 01 October 2003 (has links)
[pt] Após a incidência de inúmeros colapsos ocorridos nos sistemas de transmissão de energia devido ao uso extremo das linhas de transmissão, a estabilidade, ou mais adequadamente, a segurança de tensão tornou-se um assunto importante ao longo dos últimos anos. Este trabalho foi desenvolvido com o intuito de complementar um método de reforço das condições de estabilidade de tensão. O método consta de ações de controle para diminuir o fluxo de potência ativa no ramo crítico do caminho de transmissão mais carregado associado a uma barra crítica, conceitos estes apresentados nesta dissertação. Para o propósito citado, e considerando que o problema de estabilidade de tensão causa restrições nos fluxos de potência na rede de transmissão, são estudados métodos que analisam o congestionamento dessas redes. Se destacam algoritmos que, a partir dos fluxos de potência ativa e reativa que deixam um gerador, ou que chegam a uma carga, determinam a distribuição nos ramos de um sistema de transmissão, e o algoritmo que avalia os impactos no sistema de transmissão devido a uma determinada transação, entre barras geradoras e/ou de cargas. São mostrados exemplos numéricos que ilustram a possibilidade ou não da adequação destes métodos para o problema do reforço das condições de segurança de tensão. / [en] After a number of collapses due to the extreme use of the transmission lines, the voltage stability, or voltage security, became an important issue. This work was developed in order to contribute to a voltage security reinforcement method. The method calculates control actions to decrease the power flowing through the critical branch of the most loaded transmission path associated with the critical bus (concepts present in this dissertation). For this propose, and considering that the power flow in a transmission network may be restricted by voltage stability limits, transmission congestion analysis methods were study. Two of them deal with the contribution of real and reactive outflows of individual generator buses, and real and reactive inflows of individual load buses, in all network branches. Another method assess the impact of a given power transaction on the network. Numerical examples are presented to illustrate whether it is the possible or not to employ the studied methods in the voltage security reinforcement problem.
4

[en] VOLTAGE CONTROL SENSITIVITY CALCULATION FOR VOLTAGE STABILITY OPERATIONAL REINFORCEMENT / [pt] ADEQUAÇÃO DAS AÇÕES DE CONTROLE DE TENSÃO EM SISTEMAS ELÉTRICOS OBJETIVANDO O REFORÇO DAS CONDIÇÕES DE SEGURANÇA DE TENSÃO

LINDOMAR JACINTO DE SOUZA 23 July 2007 (has links)
[pt] O problema de estabilidade de tensão está intimamente ligado à falta de recursos e questões ambientais que limitam a expansão do sistema de transmissão. Esta realidade em conjunto com o crescimento da carga submete os sistemas elétricos a carregamentos pesados, podendo levar a situações de colapso de tensão. O desenvolvimento de métodos para avaliação do carregamento da rede de transmissão tornou-se necessário e imprescindível para que se possa entender o funcionamento do sistema nestas condições e possibilitar a sua operação de modo correto. Em relatório de força-tarefa internacional está explicitada a necessidade de uma ferramenta computacional capaz de verificar a eficácia das ações de controle de tensão na operação do sistema elétrico em tempo-real. Com esse objetivo, foi desenvolvida uma ferramenta computacional com base no sistema linearizado das equações de fluxo de carga, e de todas as outras equações de controles e limites, julgadas pertinentes, para avaliação do efeito das ações de controle de tensão. Determinase uma matriz de sensibilidade [VCS], voltage control sensitivity matrix, através da qual se pode estabelecer a relação existente entre as tensões controladas e as grandezas controladoras. Os elementos diagonais relacionam a grandeza controladora de cada equipamento com a respectiva tensão controlada. A análise do sinal desses elementos estabelece se uma determinada ação de controle será adequada ou não, isto é, se terá efeito esperado ou oposto. Os elementos fora da diagonal representam a interdependência existente entre os equipamentos controladores de tensão. A matriz de sensibilidade também permite que ações de controle de tensão sejam calculadas com o objetivo de mover um ponto de operação inadequado, ou que esteja suscetível à inadequacidade do controle de tensão, colocando-os em um ponto de operação seguro, onde ações operativas de controle de tensão tenham o efeito esperado. Os resultados da avaliação do método desenvolvido e aplicado a sistemas-teste e reais foram qualitativamente coerentes com aqueles obtidos pela resolução (analítica, iterativa por Newton ou iterativa continuada) das equações de fluxo de carga, validando a proposta. A dimensão da matriz [VCS] é proporcional ao número de barras com tensão controlada em análise. Esta matriz não é esparsa e então, quando utilizada para representar o controle de tensão realizado por um número elevado de equipamentos controladores, sua análise direta pode se tornar complexa. Portanto, uma análise baseada nos autovalores e autovetores associados à matriz [VCS] é aplicada objetivando identificar barras de tensão controlada com efeito reverso, ocorrendo de modo contrário ao esperado, e a existência de controles conflitantes. Buscam-se autovalores negativos, nulos ou próximos de zero. A localização das barras com problemas se dá através do exame dos autovetores e fatores de participação associados a esses autovalores. O cálculo e a análise da matriz de sensibilidade dos controles de tensão são executados de forma extremamente rápida e, portanto, o esforço computacional não impede que a ferramenta desenvolvida possa ser usada durante a operação em tempo-real. / [en] The voltage stability problem has been associated with environment questions and lack of financial resources for transmission system expansion. This reality together with the load growth makes the electrical system to be subject of heavy loadings, what can lead to situations of voltage collapse. The development of methods for evaluation of transmission network loading became necessary and indispensable in order to correct operation of the system under heavy loading conditions. In an international force-task report it is stated the need for analytical tools capable of verifying the voltage control action adequacy in the real-time operation. This work reports the development of a computation tool able to evaluate the effect of voltage control actions on the voltage itself. It is based the linearized load flow equations, including control and limit equations judged pertinent. The tool establishes a sensitive matrix, named [VCS] for voltage control sensitivity matrix, that relates the controlling variables and the controlled voltages. Through the analysis of the sign of each diagonal element, it is possible to know whether a specific control action is adequate or not. Moreover, the off-diagonal elements represent the interdependence among the voltage controller devices of the power system under analysis. The sensitivity matrix also allows the calculation of control actions necessary to move the operating point from an unstable area, or near by, to a secure operating region where all voltage control actions would have the expected effect. The results obtained with the voltage control sensitivity matrix applied on real and test-systems was qualitatively coherent with those calculated by analytical, iteractive by Newton-Raphson and/or continuationiteractive solution of power flow equations, validating the proposed method. The [VCS] dimension is proportional to the number of buses with controlled voltage in the system area under analysis. The matrix is not sparse and when there are a large number of voltage control equipments, its immediate analysis may be complex. Therefore, an analysis based on eigenvalues and eigenvectors associated with [VCS] matrix is used in order to identify voltage control action with opposite effect. In this case, the analysis is focused on negative eigenvalues. The identification of conflicting controls existence of any system area under analysis is a by-product. The voltage control sensitivity matrix computation and analysis are performed extremely fast. Therefore, the computational effort does not constrain its use in real-time operation.
5

[en] VOLTAGE STABILITY ASSESSMENT AND ENHANCEMENT IN VOLTAGE-CONTROLLED BUSES BY SYNCHRONOUS GENERATORS AND COMPENSATORS / [pt] AVALIAÇÃO E REFORÇO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO EM BARRAS DE TENSÃO CONTROLADA POR GERADORES E COMPENSADORES SÍNCRONOS

JORGE LEONIDAS LAFITTE VEGA 25 August 2009 (has links)
[pt] Após a incidência de alguns colapsos de tensão em sistemas de transmissão de energia a nível mundial, a segurança de tensão tornou-se um assunto de muito interesse nos últimos anos devido à importância do seu impacto. O fenômeno de estabilidade de tensão deve-se a fluxos de potência ativa e reativa excessivos na rede de transmissão e está associado às restrições ambientais e econômicas que impedem a expansão da rede. Atualmente, sabese da existência de uma máxima carga que pode ser alimentada pela rede e é a manifestação mais conhecida do fenômeno mas, também, é possível que o problema manifeste-se pela existência de uma máxima injeção de potência ativa e reativa na rede por geradores e compensadores síncronos. E mais, em situações de carregamento elevado da rede, é possível que ações de controle de tensão tenham efeito oposto ao usual. É apresentado um método seqüencial iterativo de avaliação e reforço para as condições de carregamento da rede em barras de tensão controlada, embora na literatura somente as barras de carga são analisadas. A verificação do comportamento do gerador e compensador síncrono como dispositivo de controle torna-se necessária já que, se funcionar de forma inversa, poderá levar o sistema ao colapso por problemas de tensão. Uma vez que a avaliação do carregamento da rede de transmissão detectou uma barra de geração crítica em um determinado ponto de operação, o reforço consiste do cálculo de ações de controle para aumentar a distância ou margem de potência entre a geração daquela barra e o novo máximo permitido. Muitas vezes isso pode ser conseguido através da alteração do perfil de tensão com a conseqüente redução nas perdas. Muitas outras vezes, o redespacho de potência ativa torna-se necessário. As etapas do método são: identificar a barra crítica, identificar a sub-rede utilizada para transmitir potência ativa dessa barra para as cargas, nessa sub-rede determinar o caminho e ramo mais carregados e, desviar o fluxo de potência do ramo mais carregado para outros. A seqüência é repetida até que as novas margens de potência sejam consideradas aceitáveis. Exemplos numéricos ilustrativos reais com o sistema brasileiro são apresentados. É verificado que o método proposto realmente produz os resultados desejados. / [en] After the incidence of some voltage collapses in the energy transmission systems in the world, the voltage security became an issue of great interest in the last years due to the importance of its impact. The phenomenon of voltage stability is due to the excessive active and reactive power flow in the electrical transmission network and has been associated with environment questions and lack of financial resources for transmission system expansion. Nowadays, it is well-known that there is a maximum power that the network can transmit to a load bus and is the best known manifestation of the phenomenon, but, is not familiar to many that there is a maximum power that can be injected by generators and synchronous compensators into the network. Moreover, in heavy loading conditions is possible that voltage control actions would have the inverse effect. It is shown a sequential iterative method for assessment and voltage security reinforcement in voltage-controlled buses, although the literature only the load buses are analyzed. The verification of the behaviour of the generator and synchronous compensator as control device becomes necessary since, if it works in an inverse way, it can take the system to the voltage collapse. Once the assessment is performed and is detected one generation critical bus in some operating point, the objective of the reinforcement function is to calculate adequate control actions in order to increase the distance or power margin between the actual generation and the new maximum power flow. Several times this may be achieved by voltage profile changes and consequent loss reduction. Sometimes that procedure is not enough and active generation rescheduling is recommended. The stages of the method are: identify the critical bus, identify the sub-network used to transmit active power flow from this bus to load buses, in this sub-network the critical transmission path and critical branch are determined and redirect the power flow from the branch more loaded to others. The sequence is repeated until resultant power margins are judged suitable. Illustrative real life numerical examples with the Brazilian system are provided. It is verified that the proposed method really produces the desired results.
6

Hoeffding-Tree-Based Learning from Data Streams and Its Application in Online Voltage Security Assessment

Nie, Zhijie 05 September 2017 (has links)
According to the proposed definition and classification of power system stability addressed by IEEE and CIGRE Task Force, voltage stability refers to the stability of maintaining the steady voltage magnitudes at all buses in a power system when the system is subjected to a disturbance from a given operating condition (OC). Cascading outage due to voltage collapse is a probable consequence during insecure voltage situations. In this regard, fast responding and reliable voltage security assessment (VSA) is effective and indispensable for system to survive in conceivable contingencies. This paper aims at establishing an online systematic framework for voltage security assessment with high-speed data streams from synchrophasors and phasor data concentrators (PDCs). Periodically updated decision trees (DTs) have been applied in different subjects of security assessments in power systems. However, with a training data set of operating conditions that grows rapidly, re-training and restructuring a decision tree becomes a time-consuming process. Hoeffding-tree-based method constructs a learner that is capable of memory management to process streaming data without retaining the complete data set for training purposes in real-time and guarantees the accuracy of learner. The proposed approach of voltage security assessment based on Very Fast Decision Tree (VFDT) system is tested and evaluated by the IEEE 118-bus standard system. / Master of Science / Voltage security is one of the most critical issues in the power systems operation. Given an operating condition (OC), Voltage Security Assessment (VSA) provides a tool to access whether the system is capable to withstand disturbances if there is one or more than one elements is not functioning appropriately on the power grid. Traditional methods of VSA require the knowledge of network topologies and the computational contingency analysis of various circumstances. With trained models, decision-tree-based VSA is able to assess the voltage security status by collectible measurements among the system in a real-time manner. The system topology may alter over and over by system operators in order to meet the needs of heavy load demand and power quality requirements. The proposed approach based on Very Fast Decision Tree (VFDT) system is capable of updating trained decision-tree models regarding to changes of system topology. Therefore, the updated decision-tree models is able to handle different system topology and to provide accurate security assessment of current OC again.
7

[en] INDEXES AND MARGINS FOR VOLTAGE SECURITY ASSESSMENT / [pt] ÍNDICES E MARGENS PARA AVALIAÇÃO DA SEGURANÇA DE TENSÃO

ROVER FIGUEIRO FRANCA 09 December 2003 (has links)
[pt] Apresenta-se uma abrangente ferramenta de avaliação das condições de segurança de tensão, composta de índices com significado físico / matemático, propícia para uso na operação em tempo real. A ferramenta identifica se a solução de tensão para uma carga conectada à barra i está na parte superior, na inferior e a distância ao máximo carregamento da curva V x P,Q. Neste trabalho a enfâse está no desenvolvimento da margem de potência, distância em MVA do atual ao máximo carregamento, assim como na análise do ângulo entre os vetores-gradiente dos fluxos de potência ativa e reativa chegando / saindo de barras de carga / geração. Mostra-se a evolução desses índices durante um horizonte de tempo correspondente a uma rampa de carregamento do sistema. A área Rio do sistema brasileiro foi escolhida para observação por ter seu desempenho fortemente influenciado pela coordenação entre os diversos recursos de controle internos e externos e, também por ser um grande centro de carga com sistema de suprimento radial. A implementação das lógicas desses recursos de controle, caracterizada pela escolha das barras controladas e faixas de tensão, refletiram a experiência acumulada na operação do sistema, respeitando-se todos os limites operativos Verifica-se a ocorrência de situações extremas que levariam o sistema ao colapso de tensão. Apresenta-se ainda um estudo de barras associadas à compensação série no tronco de transmissão entre Itaipu a Tijuco Preto, barras que apresentam índices com valores atípicos. Conclui-se que o método computacional de avaliação das condições de segurança de tensão é adequado para a operação em tempo real, quando é monitorada a evolução dos índices relativos a uma seqüência de diferentes pontos de operação. / [en] This work presents a comprehensive and meaningful tool for voltage security assessment adequate for real time operational monitoring. With this tool it is possible to verify if the voltage is in the upper or in the lower region of the V, P,Q curve, as well as to quantify voltage stability margin. The emphasis of this work is on the development of margins, the distance in MVA from the current to the maximum loading, as well as on the analysis of the angle between the gradient vectors of active and reactive power flow leaving / arriving generation / load buses. It is shown the evolution of the indexes during a period of time that corresponds to a system-loading ramp. The Rio and Espírito Santo area of the Brazilian electric system was chosen for observation because its performance is strongly influenced by the co-ordination between the several types of internal and external existing controls. Also because this area represents a large load centre with an almost radial transmission system. The logic implementation of these control resources, characterised by controlled buses and voltage limits choice, respecting all the operational limits, reflected the operational experience acquired by system operators. It is verified the occurrence of extreme situations that could lead to voltage collapse in the network. It is also presented a study on the buses associated with series compensation on the Itaipu - Tijuco Preto bulk transmission path that present unusual values for the indexes. It is concluded that the computational method of voltage security assessment is adequate for real time operation, when the evolution of indexes related to different operation points are monitored.
8

[en] ADEQUACY INDEXES OF VOLTAGE CONTROL ACTION FOR VOLTAGE SECURITY CONDITION REINFORCEMENT / [pt] ÍNDICES DE ADEQUAÇÃO DAS AÇÕES DE CONTROLE DE TENSÃO PARA REFORÇO DAS CONDIÇÕES DE SEGURANÇA DE TENSÃO

BERNARDO HENRIQUE TODT SEELIG 07 March 2005 (has links)
[pt] A falta de recursos e a questão ecológica têm limitado a expansão do sistema de transmissão. Esta realidade, em conjunto com o crescimento da carga, faz com que os sistemas elétricos trabalhem bastante carregados. Esta nova condição pode levar a situações de colapso de tensão. Métodos para avaliação do carregamento da rede de transmissão tornaram-se necessários e imprescindíveis para que se possa entender o funcionamento do sistema nestas condições e possibilitar a sua operação de modo correto. Ferramentas analíticas têm sido usadas para reforço das condições de segurança de tensão do sistema em tempo real, se for avaliado que o sistema não é suficientemente seguro. Ações operativas de controle são determinadas, para mover o estado do sistema para um ponto de operação seguro. Entretanto, ferramentas de avaliação e reforço não são a única necessidade. As mesmas ações de controle, que podem afastar o sistema de uma situação de instabilidade de tensão, também podem ter efeito oposto ao esperado e contribuir para o problema, podendo até mesmo levar o sistema ao colapso. Portanto, é necessário o desenvolvimento de uma ferramenta computacional para avaliar a adequação de ações de controle de tensão. Neste trabalho é proposta uma ferramenta computacional, desenvolvida com base no sistema linearizado das equações de fluxo de carga, incluindo equações de controle de tensão e limites, para a avaliação do efeito das ações de controle de tensão. São obtidos índices que permitem avaliar se a ação de controle é adequada ou não. Além disso, esses índices podem avaliar a interdependência entre os controles, porque além de indicarem o efeito do controle sobre a tensão da barra controlada, podem indicar também o efeito do controle sobre as outras barras de tensão controlada do sistema. Estes índices podem ser obtidos de forma extremamente rápida, e são adequados para uso em tempo-real. / [en] The lack of investments and the ecological matter have limited the expansion of the transmission system. This reality, together with the load growth, makes the electric systems to work heavy loaded. This new condition can lead to situations of voltage collapse. Methods for evaluation the transmission network loading became necessary and indispensable for understanding system performance under these conditions and for making possible secure operation. Analytic tools have been used to evaluate the voltage security of the system in real time. If it is evaluated that the system is not sufficiently secure in relation to voltage, control actions can be determined, in order to move the state of the system for a secure operation point. However, these tools are not the only need. The same control actions that can move away the system from a situation of voltage instability, can also have opposite effect and contribute for worsening the problem, perhaps leading to system collapse. Therefore, it is necessary the development of computational tools to evaluate the adequacy of these control actions. In this work it is proposed a computational tool, based on the linearized set of power flow equations, including equations for voltage control and limits, for the evaluation of the effect voltage control actions. Indexes that allow the evaluation whether the control action is adequate or not are obtained. The indexes can also evaluate the interdependence among the controls, because besides indicating the effect of the control action on the voltage of the controlled bus, they can also indicate the effect on the other voltage controlled buses. The indexes can be calculated in an extremely fast way, and are appropriate for use in real-time operation.
9

[en] STATIC AND DYNAMIC SIMULATION OF VOLTAGE CONTROL BY GENERATOR AND SYNCHRONOUS COMPENSATOR / [pt] SIMULAÇÃO ESTÁTICA E DINÂMICA DO CONTROLE DE TENSÃO POR GERADOR E COMPENSADOR SÍNCRONO

ARMANDO GONCALVES LEITE 17 October 2008 (has links)
[pt] O tema abordado neste trabalho é a observação e análise, em regime permanente e dinâmico, da ocorrência de um fenômeno que já foi observado em condições reais de operação do sistema elétrico brasileiro, que é a relação oposta entre a tensão de excitação de geradores e compensadores síncronos e a tensão controlada. Nessas situações, a capacidade nominal de um gerador / compensador síncrono, por exemplo, não seria útil para manter a tensão controlada. Em virtude da relação oposta, um aumento na excitação da máquina abaixaria a tensão controlada. O controle automático continuaria agindo, abaixando ainda mais a tensão. Este mecanismo pode levar o sistema ao colapso. A abordagem do problema baseou-se na verificação do comportamento do gerador / compensador como dispositivo de controle de tensão, em regime permanente e dinâmico, ante as diversas situações normais de um sistema elétrico, tais como variações do valor da tensão de referência (tensão controlada) e de carga. A análise em regime permanente utilizou um algoritmo de fluxo de carga, enquanto a análise em regime dinâmico utilizou a simulação no domínio do tempo. A real existência do fenômeno foi comprovada através de várias destas análises, mostrando inclusive a mudança da região de operação em algumas delas. Em outros casos, os resultados da análise em regime permanente não coincidiram com os da análise em regime dinâmico. / [en] The aim of this work is to investigate, in steady state and dynamic performance, the phenomenon of the opposite relationship, already observed at real operation conditions of the Brazilian Electric System, between generators and synchronous compensators excitation voltage and the controlled one. In these situations, the generator / synchronous compensator nominal capacity, for example, would not be useful to keep the voltage controlled. Due the opposite relationship, an increase in the excitation voltage would reduce the controlled voltage. The automatic control would keep acting and reducing more the voltage. This mechanism can lead the system to the collapse. The study of this problem was based in the generator / compensator behavior as a control voltage device, in steady- state and dynamic performance, front of several operation situations of electric power system, like reference voltage (controlled voltage) variation and load changing. The steady state analysis used a load flow algorithm, while the time domain simulation was utilized for the dynamic performance analysis. The real existence of the phenomenon was verified through these analyses, emphasizing the operation region changing in some of them. In other cases, the analyses results in the steady-state were different of the dynamic performance results.
10

Incorporating voltage security into the planning, operation and monitoring of restructured electric energy markets

Nair, Nirmal-Kumar 12 April 2006 (has links)
As open access market principles are applied to power systems, significant changes are happening in their planning, operation and control. In the emerging marketplace, systems are operating under higher loading conditions as markets focus greater attention to operating costs than stability and security margins. Since operating stability is a basic requirement for any power system, there is need for newer tools to ensure stability and security margins being strictly enforced in the competitive marketplace. This dissertation investigates issues associated with incorporating voltage security into the unbundled operating environment of electricity markets. It includes addressing voltage security in the monitoring, operational and planning horizons of restructured power system. This dissertation presents a new decomposition procedure to estimate voltage security usage by transactions. The procedure follows physical law and uses an index that can be monitored knowing the state of the system. The expression derived is based on composite market coordination models that have both PoolCo and OpCo transactions, in a shared stressed transmission grid. Our procedure is able to equitably distinguish the impacts of individual transactions on voltage stability, at load buses, in a simple and fast manner. This dissertation formulates a new voltage stability constrained optimal power flow (VSCOPF) using a simple voltage security index. In modern planning, composite power system reliability analysis that encompasses both adequacy and security issues is being developed. We have illustrated the applicability of our VSCOPF into composite reliability analysis. This dissertation also delves into the various applications of voltage security index. Increasingly, FACT devices are being used in restructured markets to mitigate a variety of operational problems. Their control effects on voltage security would be demonstrated using our VSCOPF procedure. Further, this dissertation investigates the application of steady state voltage stability index to detect potential dynamic voltage collapse. Finally, this dissertation examines developments in representation, standardization, communication and exchange of power system data. Power system data is the key input to all analytical engines for system operation, monitoring and control. Data exchange and dissemination could impact voltage security evaluation and therefore needs to be critically examined.

Page generated in 0.0471 seconds