• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 240
  • 9
  • 1
  • Tagged with
  • 250
  • 250
  • 249
  • 62
  • 61
  • 28
  • 28
  • 26
  • 25
  • 24
  • 22
  • 22
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

[en] PROPOSED NEW CRITERIA FOR PERFORMANCE EVALUATION OF CLINICAL LABORATORIES BY MEANS OF PROFICIENCY TESTS / [pt] PROPOSTA DE NOVOS CRITÉRIOS PARA AVALIAÇÃO DE DESEMPENHO DE LABORATÓRIOS CLÍNICOS POR MEIO DE ENSAIOS DE PROFICIÊNCIA

DIOGO JOSÉ DA SILVA JERÔNIMO 15 August 2017 (has links)
[pt] A participação de laboratórios clínicos em programas de ensaio de proficiência é uma importante ferramenta para gestão da qualidade. A maior parte das avaliações de desempenho de laboratórios clínicos por ensaio de proficiência se realiza com base no critério Z-Score, cujo valor designado é o consenso de resultados obtidos pelos participantes da rodada de proficiência, que é fortemente dependente da qualidade dos sistemas analíticos dos participantes. Utilizando uma base de dados fornecida por um provedor de ensaios de proficiência acreditado pelo INMETRO, este trabalho compara o desempenho de critérios para a avaliação da proficiência de laboratórios clínicos para medição de glicose. Consideraram-se não só critérios comumente utilizados, mas também novos critérios propostos que independem do consenso, baseados apenas em parâmetros associados ao valor designado pelo material de referência. As discrepâncias de classificação de desempenho dos laboratórios em função dos critérios de avaliação empregados indicaram inadequações da classificação baseada em critérios com parâmetros afetados pelo consenso entre participantes. O estudo também permitiu caracterizar o desempenho dos sistemas analíticos empregados pelos participantes, evidenciando-se uma discrepância significativa entre seus resultados. Os resultados do presente trabalho possibilitam analisar o impacto dos critérios utilizados no ensaio de proficiência para a adequada avaliação do desempenho dos laboratórios, contribuindo, assim, para a garantia da confiabilidade dos diagnósticos clínicos e condutas terapêuticas. / [en] The participation of clinical laboratories in proficiency testing programs is an important tool for quality management. Most evaluations of clinical laboratory performance by proficiency testing are carried out based on the Z-Score criterion; whose assigned value is the consensus of results obtained by the participants of the round, which is heavily dependent on the quality of analytical systems of participants. Using a database provided by a proficiency testing provider accredited by INMETRO, this paper compares the performance of criteria for the assessment of proficiency of clinical laboratories for measuring glucose. The analysis considered not only commonly used criteria, but also new proposed criteria that are independent of the consensus effect, based only on parameters associated with the assigned value defined by the reference material. The observed discrepancies in the performance rating of laboratories, according to the evaluation criteria employed, allowed the evidencing of inadequacies in the classifications based on criteria using parameters affected by the consensus among participants. The study also characterized the performance of analytical systems employed by the laboratories, evidencing a significant discrepancy between the results its. The present work allowed a better understanding of the impact of criteria applied in proficiency testing programs on the adequacy of evaluation of laboratories performance, thus contributing to ensuring the reliability of clinical diagnostics and therapeutical procedures.
162

[en] DESIGN OF HYDROMETER BASED ON A THIN-FILM RESISTIVE SENSOR FOR MEASURING / [pt] PROJETO DE HIDRÔMETRO BASEADO EM UM SENSOR RESISTIVO DE FILME FINO PARA MEDIÇÃO DE CONSUMO DE ÁGUA EM UNIDADES AUTÔNOMAS

LAIS DOS SANTOS GONCALVES 01 September 2022 (has links)
[pt] Em consequência de modificações econômicas, populacionais e nos padrões de consumo, a utilização de água doce aumentou significativamente nos últimos 100 anos. Notoriamente, a medição mostra-se primordial para estimular a conservação da água. Sendo assim, esta dissertação tem por intuito contribuir para o aprimoramento das tecnologias dos hidrômetros, mais especificamente para medição do volume de água escoado em uma tubulação de unidades autônomas em edifícios. Com isso, o presente estudo objetiva avaliar a aplicabilidade de um sensor resistivo de filme fino (bend sensor), com diferentes revestimentos e comprimentos, para implementação em sistemas de medição individualizada de água. Além disso, a motivação deste trabalho é propor um hidrômetro utilizando as válvulas de controle de fluxo que, normalmente, já estão presentes nas instalações hidráulicas condominiais, evitando, assim, a necessidade de obras maiores em prédios antigos, que possuem medição coletiva de consumo de água. Metodologicamente, apresenta-se o sistema desenvolvido para as caracterizações eletromecânica e térmica do sensor, a simulação computacional do sensor realizada por meio do software Ansys e do circuito eletrônico feita no software LTspice (marca registrada) , o treinamento de uma rede neural artificial e as estimativas de volume a partir de pulsos trapezoidais. Os resultados obtidos permitiram avaliar, levando em consideração o tipo de revestimento, que o sensor revestido com poliéster possui um melhor comportamento para o hidrômetro proposto. Além disso, esta avaliação permitiu concluir que o bend sensor demonstrou viabilidade para ser utilizado como transdutor deste medidor volumétrico, podendo ser facilmente inserido dentro de algum componente hidráulico, como uma válvula de controle de fluxo, por exemplo. / [en] As a result of economic, population, and consumption patterns changes, the use of freshwater has increased significantly in the last 100 years. Notably, measurement is essential to encourage water conservation. Therefore, this dissertation aims to contribute to the advancement of water meter technologies, specifically for measuring the volume of water drained in a pipeline of autonomous units in buildings. Thus, the present study aims to evaluate the applicability of a thin-film resistive sensor (bend sensor) with different coatings and lengths for implementation in individualized water measurement systems. In addition, the motivation of this work is to propose a volumetric meter using flow control valves that, ordinarily, are already present in the buildings hydraulic installations, thus avoiding the need for large-scale works in old buildings, which have collective measurement of water consumption. Methodologically, it is presented the system developed for the electromechanical and thermal characterization of the sensor, the computational simulation of the sensor performed using the Ansys software, and of the electronic circuit designed in LTSpice (trademark) software, the training of artificial neural network and the volume estimates from trapezoidal pulses. The results obtained allowed us to assess that, taking into account the type of coating, the sensor coated with polyester has better behavior for the proposed hydrometer. In addition, this evaluation allowed to conclude that the bend sensor demonstrated the feasibility to be used as a transducer of this volumetric meter and can be easily inserted inside a hydraulic component, as a flow control valve, for example.
163

[pt] AVALIAÇÃO DA INFLUÊNCIA DO TEOR DE ÁGUA EM ÓLEO SOBRE O DESEMPENHO METROLÓGICO DE SISTEMAS DE MEDIÇÃO DE VAZÃO DE PETRÓLEO / [en] EVALUATION OF THE INFLUENCE OF WATER CONTENT IN OIL ON THE METROLOGICAL PERFORMANCE OF OIL FLOW MEASUREMENT SYSTEMS

AUGUSTO PROENCA DA SILVA 07 November 2022 (has links)
[pt] Esta dissertação teve como objetivo de avaliar o desempenho metrológico de sistemas de medição de petróleo com medidores de vazão do tipo ultrassônico, Coriolis e deslocamento positivo quando submetidos a variadas condições de BSW, temperatura do fluido e vazão do escoamento por meio de Planejamento de Experimentos e da Metodologia de Superfície de Resposta. Conforme regulamentação brasileira vigente, caso os volumes produzidos de petróleo utilizados como referência para o pagamento de participações governamentais e a terceiros contenham um BSW superior a 2 por cento v/v, estes volumes devem ser majorados de forma arbitrária entre 1,44 por cento e 10,89 por cento em função exclusivamente do BSW, o que tem acarretado problemas operacionais às empresas petrolíferas como diferenças entre os volumes produzidos e os volumes comercializados, e pagamentos adicionais de participações governamentais e à terceiros. Os resultados dos experimentos realizados indicam que a contribuição de cada parâmetro analisado para o desempenho metrológico do sistema de medição varia conforme a tecnologia de medição utilizada pelo medidor de vazão, entretanto a temperatura do fluido demonstrou-se um parâmetro relevante comum para todas as tecnologias de medição avaliadas. Todas as tecnologias de medição avaliadas sofrem influência do BSW na faixa de 0 por cento a 10 por cento v/v, sendo o erro de medição inferior a 0,2 por cento, quando comparado a um medidor padrão do tipo deslocamento positivo, em quase todas as condições experimentais. O medidor de vazão do tipo Coriolis foi o que apresentou o menor erro dentre as tecnologias de medição avaliadas. / [en] This dissertation aimed to evaluate the metrological performance of oil measurement systems with ultrasonic, Coriolis and positive displacement flowmeters when subjected to various conditions of BSW, fluid temperature and flow rate by using Design of Experiments and Response Surface Methodology. According to current Brazilian regulations, if the produced oil volumes used as a reference for the payment of government takes and to landowners contain a BSW greater than 2 percent v/v, these volumes must be arbitrarily increased by 1.44 percent up to 10.89 percent due exclusively to the BSW value, which has caused operational problems for oil companies such as differences between the produced oil volumes and oil volumes sold, and additional payments of government takes and landowner fees. The results of the experiments carried out indicate that the contribution of each parameter analyzed to the metrological performance of the measurement system varies depending on the flowmeter measurement technology, however, the fluid temperature proved to be a relevant parameter common to all measurement technologies evaluated. All measurement technologies evaluated are influenced by BSW in the range of 0 percent to 10 percent v/v, with the measurement error being less than 0.2 percent, when compared to positive displacement master flowmeter, in almost every experimental condition. The Coriolis flowmeter was the one with the lowest error among all measurement technologies evaluated.
164

[en] DESIGN OF EXPERIMENTS FOR METROLOGICAL OPTIMIZATION AND RELIABILITY OF A NEW PH MEASUREMENT SYSTEM IN HYDRATED FUEL ETHANOL / [pt] PLANEJAMENTO DE EXPERIMENTOS PARA OTIMIZAÇÃO E CONFIABILIDADE METROLÓGICA DE UM NOVO SISTEMA DE MEDIÇÃO DE PH EM ETANOL HIDRATADO COMBUSTÍVEL

NATALIA CAMBIAGHI ATILIO 08 November 2022 (has links)
[pt] O pH constitui um dos parâmetros de controle de qualidade do etanol combustível, sendo estabelecido pela norma brasileira ABNT NBR 10891, cujo escopo é específico para etanol hidratado combustível, e pela norma americana ASTM D 6423, a qual o foco é o etanol anidro combustível. Neste contexto, o presente estudo apresenta uma análise crítica à composição dos eletrodos utilizados pelos diferentes sistemas de medições para pH de etanol, devido à presença de água na composição do eletrodo de vidro. Com isso, o objetivo do presente estudo consistiu em uma proposta de um novo sistema para medição de pH de etanol hidratado combustível, o qual foi o único solvente utilizado, empregando como referência indicadores ácido-base. Por meio do planejamento de experimentos Box-Behnken foi possível determinar a condição otimizada esperada para o novo sistema de medição, o qual foi comparado com os sistemas propostos pelos referenciais normativos e posteriormente com o intervalo de pH definido pelos indicadores. Os resultados revelaram que os valores de pH obtidos pelos diferentes sistemas utilizados, incluindo o proposto pelo presente estudo, são estatisticamente diferentes entre si, e que somente os valores obtidos pelo novo sistema de medição se adequa à faixa de pH encontrada pelos indicadores. O eletrodo otimizado apresentou uma sensibilidade de resposta adequada à equação de Nernst, tendo um comportamento operacional adequado ao novo sistema de medição proposto pelo presente estudo. / [en] The pH is one of the quality control parameters of fuel ethanol, established by the Brazilian standard ABNT NBR 10891, whose scope is specific for hydrated fuel ethanol, and by the American standard ASTM D 6423, which focuses on anhydrous ethanol fuel. In this context, the present study presents a critical analysis of the composition of the electrodes used by the different measurement systems for ethanol pH, due to the presence of water in the composition of the glass electrode. Thus, the objective of the present study was to propose a new system for measuring the pH of hydrated fuel ethanol, which was the only solvent used, using acid-base indicators as a reference. Box-Behnken Design made possible to determine the optimal condition expected for the new measurement system, which was compared with the systems proposed by the normative references and later with the pH range defined by the indicators. The results revealed that the pH values obtained by the different systems used, including the one proposed by the present study, are statistically different from each other, and that only the values obtained by the new measurement system are suitable for the pH range found by the indicators. The optimized electrode presented an adequate response sensitivity to the Nernst equation, having an operational behavior adequate to the new measurement system proposed by the present study.
165

[en] PROPOSAL OF A PORTABLE MULTISENSOR BIOMEDICAL DEVICE FOR DETECTION OF FERROMAGNETIC FOREIGN BODIES / [pt] PROPOSTA DE DISPOSITIVO BIOMÉDICO MULTISENSOR PORTÁTIL PARA LOCALIZAÇÃO DE CORPOS ESTRANHOS FERROMAGNÉTICOS

MELISSA CARVALHO COSTA 21 November 2022 (has links)
[pt] Os procedimentos atuais de localização de corpos estranhos ferromagnéticos utilizados na prática clínica envolvem as técnicas de imageamento de radioscopia e radiografia, que apresentam diversas limitações e riscos. Assim, técnicas de localização baseadas em magnetômetros como SQUID, GMI e GMR têm sido desenvolvidas, com variados graus de complexidade e sucesso. Uma das principais dificuldades de ordem prática, além do custo e das dimensões do sistema de medição no caso do SQUID, que opera a temperaturas criogênicas, é a necessidade de o paciente estar posicionado em uma estrutura móvel de grandes dimensões que permita a determinação das coordenadas da posição bidimensional do mapeamento magnético. Por outro lado, as pequenas dimensões dos sensores GMR ou GMI possibilitam o desenvolvimento de um sistema de medição portátil que poderia integrar outros sensores que em conjunto viabilizem a determinação da posição espacial do sensor magnético em relação ao paciente. Esta dissertação de mestrado investiga técnicas de determinação da posição espacial de um dispositivo portátil, baseado em uma plataforma Raspberry Pi, integrando sensor GMR, câmera, sensores inerciais e um sensor de distância, visando ao futuro desenvolvimento de um protótipo de dispositivo médico portátil para localização de corpos estranhos ferromagnéticos. A pesquisa também investiga técnicas de resolução do problema inverso magnético em tempo real baseadas em filtros de Kalman e ajuste por mínimos quadrados, de modo a acelerar o procedimento diagnóstico na futura aplicação clínica do dispositivo. / [en] The current procedures for locating ferromagnetic foreign bodies used in the clinic involve radioscopy and radiography image techniques, which presents several limitations and risks. Thus, localization techniques based on magnetometers were developed as SQUID, GMI and GMR, with varying degrees of complexity and success. One of the main difficulties, in addition to the cost and dimensions of the system, in the case of the SQUID, which operates at cryogenic temperatures, is the need for the patient to be positioned in a large structure that allows flexibility in the configurations of the two-dimensional position of the magnetic mapping. On the other hand, the small dimensions of the GMR or GMI sensors allow the development of a portable measurement system that could integrate other sensors that together make it possible to determine the spatial position of the magnetic sensor in relation to the patient. This master s dissertation investigates techniques for determining the spatial position of a portable device, based on a Raspberry Pi platform, integrating GMR sensor, camera, inertial sensors and a distance sensor, aiming at the future development of a prototype of a portable medical device for localization of ferromagnetic foreign bodies. The research also investigates real-time inverse magnetic problem solving techniques based on Kalman filters and least squares adjustment, in order to accelerate the diagnostic procedure in the future clinical application of the device.
166

[en] DESIGN OF A SYSTEM FOR DETECTION OF NONFERROMAGNETIC METALLIC FOREIGN BODIES BASED IN EDDY CURRENTS AND GMI MAGNETOMETER / [pt] PROJETO DE SISTEMA DE DETECÇÃO DE CORPOS ESTRANHOS METÁLICOS NÃO-FERROMAGNÉTICOS BASEADO EM EDDY CURRENTS E MAGNETÔMETRO GMI

VINICIUS TOSTES SEIXAS 21 November 2022 (has links)
[pt] Esta dissertação apresenta um projeto de sistema portátil de localização de corpos estranhos metálicos não ferromagnéticos por meio de mapeamento magnético. O sistema baseia-se na indução de correntes parasitas no corpo estranho por um estágio de excitação e na medição por um magnetômetro GMI comercial de elevada resolução (25 pT). A topologia do instrumento é baseada no desacoplamento dos estágios de excitação e medição, com uma configuração que produz linhas de campo magnético primário elevadas na região do corpo estranho e tênues na região do sensor. Esta característica supera as limitações de um instrumento previamente desenvolvido, permitindo aumentar o campo magnético primário de excitação sem saturar o magnetômetro. O projeto é baseado em simulações computacionais, considerando dois tipos de excitação e duas orientações para o eixo de sensibilidade do magnetômetro. Diretrizes internacionais para os limites de exposição à radiação não-ionizante, aspectos biometrológicos, construtivos e elétricos também foram levados em consideração no projeto. A análise de desempenho das configurações mais promissoras confirmou a viabilidade do instrumento de medição proposto, otimizando a operação linear do magnetômetro durante o procedimento de medição e contribuindo para a futura construção de um protótipo de sistema de medição completo, com características de desempenho e segurança asseguradas para a aplicação biomédica pretendida. / [en] This dissertation presents a portable system for the localization of nonferromagnetic foreign metal bodies by magnetic mapping. The system is based on the induction of eddy currents in the foreign body by an excitation stage and the measurement by a high resolution commercial GMI magnetometer (25 pT). The instrument topology is based on the decoupling of the stages of excitation and measurement, with a configuration that produces a high primary magnetic field in the foreign body region and a weak one in the sensor region. This feature surpasses the limitations of a previously developed instrument, allowing to increase the primary excitation magnetic field without saturating the magnetometer. The project is based on computational simulations, considering two types of excitation and two orientations for the magnetometer sensitivity axis. International guidelines for exposure limits to non-ionizing radiation, biometrological, constructive and electrical aspects were also taken into consideration in the project. The performance analysis of the most promising settings confirmed the viability of the proposed measurement instrument, optimizing the linear operation of the magnetometer during the measurement procedure and contributing to the future construction of a complete measurement system prototype, with performance and safety characteristics ensured for the intended biomedical application.
167

[pt] MEDIÇÃO DO TEOR DE ÁGUA EM MISTURAS ÓLEO-ÁGUA PELA VELOCIDADE DO SOM / [en] WATER CONTENT IN WATER-OIL MIXTURE BY SPEED OF SOUND MEASUREMENT

BRUNO NEPOMUCENO DOS SANTOS 11 October 2023 (has links)
[pt] Medidores do tipo ultrassônicos são calibrados para medição de vazão de um único fluido. Entretanto, ao extrair petróleo de um poço, a separação trifásica não é suficiente para separar totalmente a água do óleo e a medição de vazão indicada do fluido acaba sendo maior do que o mensurando devido à presença de água não contabilizada na mistura, o que muitas vezes acontece nos escoamentos dentro de tubulações. Foi desenvolvida uma metodologia para medição contínua e automática do teor de água na mistura óleo-água, medindo-se a velocidade do som, por medidores ultrassônicos que podem ser intrusivos ou não intrusivos (clamp-on) para medição de vazão que foram anteriormente instalados e compõem as malhas de processo das plantas de exploração e refino de petróleo, em conjunto com a determinação da velocidade do som e massas específicas da água pura e do óleo diesel. Este trabalho mostra uma redução da incerteza de medição quando a indicação da fração de água através da medição da velocidade do som na mistura óleo-água é diretamente relacionada a medições rastreáveis da fração de água e temperatura de uma mistura óleo-água previamente preparada e conhecida, que foi utilizada como sistema de calibração para medições do teor de água. A incerteza de medição calculada para medição da fração de água é de 0,25 por cento com um grau de confiança de 95,45 por cento, sendo obtida através de uma curva de ajuste dos dados em uma faixa de medição de 0 por cento - 2,5 por cento. A incerteza calculada é menor e, portanto, atende aos requisitos de medição fiscal (menor que 1 por cento) vigentes no país. / [en] Ultrasonic meters are calibrated for flowrate measurement of pure oil flows. However, the multiphase separation is not enough to totally separate water and oil and the indicated oil flow rate is larger than its true value when water is mixed with oil in the flow, as usual in pipeline flows. A methodology was developed to measure the water content of water-oil mixtures automatically, using the already measured speed of sound by installed intrusive or non-intrusive (clamp on type) ultrasonic meters for flowrate measurement. That measure together with the previously determined speed of sound and density of pure water and oil as a function of temperature, thus avoiding additional meters. This dissertation shows a reduction of the uncertainty of measurement when the meter indicated water-oil mixture speed of sound is directly related to the traceable measurements of water content and temperature of previously prepared water-oil mixtures, what turns out to be the meter calibration for water content measurement. Water content uncertainty value of 0.25 per cent, 95.45 per cent level of confidence, is obtained when curve fitting de data in the 0 per cent - 2.5 per cent range, that covers the fiscal measurement range (less than 1 per cent).
168

[en] ASSESSMENT OF ENERGY LOSSES AND CHARACTERIZATION OF THE RESALE AND MAINTENANCE MARKET OF REFURBISHED ELECTRIC MOTORS IN BRAZIL / [pt] AVALIAÇÃO DAS PERDAS ENERGÉTICAS E CARACTERIZAÇÃO DO MERCADO DE REVENDA E DE MANUTENÇÃO DE MOTORES ELÉTRICOS RECONDICIONADOS NO BRASIL

RODRIGO SANTOS VIEIRA 20 February 2019 (has links)
[pt] Os motores elétricos no Brasil são responsáveis pelo consumo de cerca de 25 porcento de toda a energia elétrica no país e, em sua grande parte, estão presentes na indústria. Estes equipamentos são fabricados para uso em bombas hidráulicas, compressores de ar, elevadores etc., podendo ser comercializados se atenderem aos índices de eficiência mínimos definidos pela Portaria INMETRO/MDIC N488 de 2010, garantindo o seu perfeito funcionamento e o consumo energético adequado. Contudo, alguns estabelecimentos estão comercializando produtos usados recondicionados, não atendendo à regulamentação desta Portaria, além de reformarem motores sem condições de uso. O objetivo desta dissertação é dimensionar e caracterizar o mercado de revenda e manutenção de motores elétricos de indução recondicionados no Brasil, estimando a perda de energia decorrente do recondicionamento incorreto. A metodologia do trabalho pode ser dividida em cinco etapas: estudo do estado da arte de recondicionamento de motores; quantificação de empresas e funcionários por meio de consultas às bases de dados governamentais; pesquisa de campo em amostras de empresas que fazem recondicionamento; extrapolação do estudo conduzido nas amostras para a população de empresas pesquisadas durante a pesquisa de campo; comparação dos resultados com estudos anteriores e dimensionamento das perdas elétricas do Brasil. Como resultado foi caracterizado e dimensionado o mercado de motores recondicionados, contendo: 6.503 empresas; 24,4 mil funcionários; 45 porcento das empresas realizando revenda de recondicionados; 6,9 milhões de motores recondicionados por ano, totalizando 7,46 porcento de perda, equivalentes a 2,9 Terawatt-hora. Além disso, dos 20 milhões de motores existentes no Brasil em 2016 há uma perda de 8,4 Terawatt-hora por uso de motores recondicionados e um grande aumento da venda de motores importados de baixa qualidade. Foram, assim, atingidos todos os objetivos propostos nesta pesquisa, sendo identificadas as novas tendências do mercado de motores brasileiro e gerando subsídios para o desenvolvimento de novas políticas de eficiência energética no país. / [en] Electric motors in Brazil are responsible for the consumption of about 25 percent of all electricity in the country and, being mostly presented in the industry. These equipments are manufactured for being used in hydraulic pumps, air compressors, elevators, etc., and can be commercialized in compliance with the energy efficiency levels defined by INMETRO/MDIC Ordinance N488 of 2010, ensuring adequate energy consumption. However, some establishments are commercializing refurbished motors, not complying with the regulation considered by the Ordinance, including reforming motors without a minimum condition of use. The aim of this dissertation is to evaluate the Brazilian market of refurbished motors, including resale market and maintenance market, estimating the energy losses due to incorrect reconditioning. The methodology of the work can be divided in five steps: state of the art of refurbished motors; quantifying companies and employees by querying the database come from the government; survey on samples of companies that are doing the refurbishing service; extrapolation of the study conducted in the surveyed samples of companies to the population of companies; comparison of results with previous studies and estimating of energy losses in Brazil. As a result, the market for refurbished motors was characterized and dimensioned, containing: 6 503 companies; 24.400 employees; 45 percent of companies performing resale of refurbished motors; 6.9 million motors being refurbished per year, totaling 7.46 percent of energy losses, equivalent to 2.9 TW h. In addition, of the 20 million motors remaining in Brazil in 2016, there is a loss of 8.4 TW h per use of refurbished motors, and a large increase of the sale of low quality imported motors. Thus, all the proposed objectives in this dissertation were achieved, having been identified the new trends in the Brazilian electric motor market and generating subsidies for energy efficiency policies in the country.
169

[pt] ESTRATÉGIA HÍBRIDA DAS ABORDAGENS QUALITY BY DESIGN E FAILURE MODE AND EFFECT ANALYSIS PARA APLICAÇÃO NO DESENVOLVIMENTO DE TECNOLOGIA BIOMÉDICA / [en] HYBRID STRATEGY OF QUALITY BY DESIGN AND FAILURE MODE AND EFFECT ANALYSIS APPROACHES FOR APPLICATION IN BIOMEDICAL TECHNOLOGY DEVELOPMENT

MARIA ALEXANDRA MATALLANA CASTELLANOS 12 January 2023 (has links)
[pt] Este trabalho apresenta a estratégia híbrida das abordagens Quality by Design e Failure Mode and Effects Analysis para aplicação no desenvolvimento de tecnologia biomédica. A qualidade e a gestão de riscos precisam evoluir com o avanço do desenvolvimento farmacêutico e tecnológico na saúde, permitindo um maior controle dos processos de fabricação de cada dispositivo biomédico. A Análise de Modo e Efeito de Falha (FMEA) tem sido amplamente utilizada na saúde para garantir a qualidade dos produtos fabricados. Ela se dedica a prevenir eventos ou incidentes adversos, identificando falhas para priorizar o risco e otimizando recursos, para uma melhor qualidade em dispositivos ou equipamentos médicos. A Qualidade por Projeto (QbD), por sua vez, tem sido aplicada na indústria farmacêutica para garantir a qualidade dos produtos desde a fase de desenvolvimento. Os resultados obtidos com a estratégia híbrida desenvolvida determinaram os atributos da qualidade e os parâmetros do processo mais críticos para aplicação no desenvolvimento de sistema de medição para localização de corpo estranho metálico em pacientes. A abordagem QbD-FMEA contribuiu para a determinação mais adequada e abrangente dos elementos críticos mais relevantes e associadas ações preventivas do que o emprego dessas sistemáticas isoladamente. / [en] This work presents the hybrid strategy of Quality by Design and Failure Mode and Effects Analysis approaches for application in biomedical technology development. Quality and risk management need to evolve with the advancement of pharmaceutical and technological development in healthcare, allowing greater control of the manufacturing processes of each biomedical device. Failure Mode and Effect Analysis (FMEA) has been widely used in healthcare to ensure the quality of manufactured products. It is dedicated to preventing adverse events or incidents, identifying failures to prioritize risk, and optimizing resources for better medical devices or equipment quality. In turn, Quality by Design (QbD) has been applied in the pharmaceutical industry to ensure product quality from the development phase. The results obtained with the developed hybrid strategy determined the most critical quality attributes and process parameters for application in developing a measurement system for metallic foreign body location in patients. The hybrid QbD-FMEA approach contributed to a more adequate and comprehensive determination of the most relevant critical elements, associating with preventive actions, than the isolated use of these approaches.
170

[en] FLEXABRASION APPLIED TO THE EVALUATION OF THE PHOTODEGRADATION OF HAIR FIBERS / [pt] FLEXABRASÃO APLICADA À AVALIAÇÃO DA FOTODEGRADAÇÃO DE FIBRAS CAPILARES

NATHALIA FERRO DE OLIVEIRA 30 April 2019 (has links)
[pt] A irradiação solar é vista como uma importante fonte de dano aos cabelos, contudo, medir instrumentalmente as consequências da sua interação com os diferentes constituintes da fibra capilar ainda é um desafio. Neste trabalho, investigou-se o potencial da metodologia de flexabrasão em medir as alterações nas propriedades mecânicas de fibras de cabelo decorrentes dos danos estruturais ocasionados pelas radiações solares. Para isto, desenvolveu-se um experimento in-vitro, no qual amostras de cabelo humano, simulando diferentes níveis de sensibilização química (natural, descolorido, colorido e alisado com formaldeído), foram submetidas a diferentes níveis de radiação emitida por uma lâmpada de xenônio. Após análise estatística dos dados obtidos, observou-se que a metodologia de flexabrasão é capaz de captar a influência da radiação solar na resistência mecânica de fibras de cabelo, sobretudo em cabelos naturais a partir de 60 horas de exposição à lâmpada de xenônio, o que equivale aproximadamente a 5 meses de exposição solar na cidade do Rio de Janeiro, para pessoas que ficam diretamente expostas ao sol por cerca de 1,5 h por dia. Desta forma, concluiu-se que a flexabrasão é uma possível metodologia para avaliação do fator de proteção solar oferecido por produtos cosméticos capilares. / [en] Solar radiation is an important source of damage to hair fibers. However, it is still a huge challenge to instrumentally measure the consequences of its interaction with the fibers constituents. In this work, the flexabrasion methodology has been investigated as a potential tool to quantify the alterations on hair mechanical properties due to structural damages caused by solar radiation. For that, an in-vitro experiment has been developed, in which human hair samples, simulating different levels of chemical sensitization (natural, bleached, dyed and straightened with formaldehyde), were submitted to different levels of radiation from a xenon lamp source. Statistical analysis of the data obtained with the methodology showed that it is able to capture the influence of solar radiation on hair mechanical resistance, especially when using natural fibers from 60 hours of exposure onwards, what would be equivalent to around 5 months of real solar exposure at Rio de Janeiro, on people that are directly exposed to the sun during 1,5 h per day. Thus, one can conclude that flexabrasion is a methodology option to evaluate the photo protection efficacy offered by hair care products.

Page generated in 0.035 seconds