• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 12
  • 12
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] TREATMENT OF EFFLUENTS CONTAINING CYANIDE BY SINGLET OXYGEN GENERATED BY THE REACTION OF HYDROGEN PEROXIDE AND SODIUM HYPOCHLORITE / [pt] TRATAMENTO DE EFLUENTES CONTENDO CIANETO POR OXIGÊNIO SINGLETE GERADO ATRAVÉS DA REAÇÃO DE PERÓXIDO DE HIDROGÊNIO E HIPOCLORITO DE SÓDIO

MERYELEM TANIA CHURAMPI ARELLANO 16 August 2013 (has links)
[pt] O presente trabalho teve como objetivo estudar a viabilidade da aplicação do processo oxidativo avançado que utiliza oxigênio singlete, gerado quimicamente por peróxido de hidrogênio e hipoclorito de sódio, para oxidar o cianeto livre. O processo foi estudado em batelada, simulando uma solução sintética de KCN com características de pH e concentração similares às condições típicas de um efluente real. A combinação aquosa do H2O2 e NaClO para gerar oxigênio singlete, foi eficaz para oxidar o cianeto, em uma faixa de pH 9 a 11. Com concentrações iniciais de cianeto de 10, 100, 500 e 1000 mg/L, e proporção molar de [H2O2maisNaClO]:[CN-]igual a 2:1, foi possível atingir uma concentração final de cianeto menor do que 0,2 mg/L, com 98,9 por cento e 99 por cento de remoção, a pH 11 e 9, em apenas 2 e 20 minutos, respectivamente. Quando o cianeto foi oxidado por H2O2 e NaClO separadamente, para as mesmas condições experimentais, o peróxido de hidrogênio apenas oxidou o cianeto em 30 por cento e 26 por cento, a pH 9 e 11, respectivamente, em 60 minutos de reação. Quando o cianeto foi oxidado com NaClO, o cianeto atingiu uma concentração final menor do que 0,2 mg/L, com uma remoção de 98 por cento e 99 por cento, a pH 9 e 11, em 60 e 5 minutos de reação, respectivamente. / [en] The synergistic combination of hydrogen peroxide and hypochlorite ion in water results in formation of the highly oxidizing intermediate species singlet oxygen (1O2), which is effective in the oxidation of free cyanide (CN-) in water. The process was fast and efficient over the studied pH range of 9-11, and up to an initial CN- concentration of 1000 mg/L. For an initial [CN-] equal 100 mg/L, pH equal 9, and molar ratio ([H2O2]more[NaClO])/[CN-] equal 1:1 it was possible to achieve a final concentration of [CN-] lower than 0.2 mg/L (99.8 per cent reduction) in t equal 20 min at 25 degrees celsius in a batch reaction. By comparison, the same reaction with either of the separate oxidants (H2O2 or NaClO) at the same molar ratio of oxidant/CN- equal 1:1 resulted in a maximum of 87 per cent breakdown of the cyanide (using NaClO) for the same 20 min reaction period.
2

[en] TREATMENT OF EFFLUENTS CONTAINING AMMONIA / [pt] TRATAMENTO DE EFLUENTES CONTENDO AMÔNIA

NATALI BELLIDO ORDONEZ 20 October 2003 (has links)
[pt] A presente dissertação investiga a capacidade de remoção de amônia de efluentes através de processos de oxidação química. Testes preliminares foram feitos com peróxido de hidrogênio (H2O2), peróxido de hidrogênio foto ativado (UV + H2O2), reagente Fenton (Fe2+ + H2O2) e Ácido de Caro (H2SO5). Os resultados dos mesmos indicaram apenas a possibilidade do Ácido de Caro oxidar a amônia. Em seguida avaliou-se o desempenho do Ácido de Caro no processo, utilizando soluções sintéticas de cloreto de amônia. Foi estudada a influência dos parâmetros pH, tempo, e razão estequiométrica (oxidante:amônia). O tratamento de soluções com Ácido de Caro, mostrou-se viável, visto que houve uma redução significativa da concentração inicial de amônia de 100 mg/L até valores inferiores a 5 mg/L (limite permitido pela legislação). Estes resultados foram obtidos a pH=1,3 razão estequiométrica oxidante:amônia = 8:1, em tempo de reação de 12 horas, a temperatura ambiente. / [en] This dissertation investigates the removal capacity of ammonia from effluents by chemical oxidation. Preliminary tests were done with hydrogen peroxide (H2O2), photo activated hydrogen peroxide (UV + H2O2), Fenton reagent (Fe2+ + H2O2) and Caro s Acid (H2SO5). The results indicated that only the use of Caro s acid is possible for ammonia oxidization. Afterwards, the Caro s acid process was evaluated, utilizing synthetic solutions of the ammonia chloride. The influence of parameters: pH, time, and stoichiometric ratio (oxidizing agent:ammonia) were studied. The treatment of the solutions with Caro s Acid was found to be viable, showing that there was a significant reduction of initial concentration of ammonia of 100mg/L down to 5mg/L (the limit permitted by legislation). These results were obtained for the following parameter: pH=1,3, stoichiometric ratio (oxidizing agent:ammonia) = 8:1, at reaction time of 12 hours and at ambient temperature.
3

[en] COOLING WATER TREATMENT USING HYDROGEN PEROXIDE / [pt] TRATAMENTO DE ÁGUAS DE RESFRIAMENTO COM PERÓXIDO DE HIDROGÊNIO

FERNANDO ANTONIO SERRAPIO PERES 24 August 2006 (has links)
[pt] O tratamento de águas de resfriamento normalmente é feito com a adição de cloro, porém este produto apresenta algumas desvantagens em sua aplicação. Como alternativa ao cloro, algumas indústrias no Brasil e no exterior estão começando a utilizar outros biocidas, dentre estes o peróxido de hidrogênio, um poderoso oxidante que apresenta forte ação biocida. O objetivo deste trabalho foi comparar a eficiência do cloro e do peróxido de hidrogênio como biocidas em diferentes condições, através de testes em água da torre de resfriamento de uma indústria siderúrgica localizada no Rio de Janeiro. A contaminação microbiológica desta água foi medida sem a adição dos biocidas e com a adição de cloro e peróxido de hidrogênio, permitindo assim comparar o desempenho destas substâncias no combate aos grupos bacterianos presentes na amostra. Foi realizado também um estudo sobre o efeito corrosivo destas substâncias através de testes de corrosão em aço carbono 1020, que permitiram avaliar a taxa de corrosão por perda de massa provocada pela aplicação destes produtos na água. Os resultados mostraram que o peróxido de hidrogênio possui uma ação biocida satisfatória para aplicações em águas de resfriamento. Foi constatado que o efeito biocida do peróxido de hidrogênio é mais limitado do que o cloro e que sua eficiência depende do tempo de contato e pode ser afetada pela presença de impurezas dissolvidas na água. Os ensaios de corrosão revelaram que o peróxido de hidrogênio provoca um efeito corrosivo comparável ao do cloro no material testado. / [en] Cooling water treatment generally is made with the addition of chlorine, although it´s application has some disadvantages. There is an active development in Brazil and other countries to use alternative chemical disinfectants in place of chlorine, such as hydrogen peroxide, a powerful oxidant which is known for its high biocidal efficiency. The aim of this research is to study the effectiveness of hydrogen peroxide as a disinfectant compared to chlorine in different operational conditions. The experiments were carried out using an water sample from a cooling water system of a steelmaking plant in the city of Rio de Janeiro. The microbial contamination of this water sample was measured without adding any kind of disinfectant. After that, water sample was treated by adding hydrogen peroxide and chlorine, in order to compare and evaluate the efficiency of the two biocides to control bacterial growth in water. Besides microbiological tests, experiments were conducted to compare the degree of corrosion caused by the addition of hydrogen peroxide and chlorine in water. The experimental methodology employed 1020 carbon steel specimens and corrosion rates were measured by weight loss determination after the period of exposure. The results showed that the application of hydrogen peroxide leads to satisfactory bacterial control. However, compared to chlorine, hydrogen peroxide is a rather poor disinfectant. The efficiency of hydrogen peroxide depends on reaction time and it is affected by dissolved polluants in water. Evaluation of corrosion rates showed that hydrogen peroxide causes basically the same corrosion rates than chlorine.
4

[en] TREATEMENT WASTEWATER EFFLUENTS CONTAINING HYDRAZINE / [pt] TRATAMENTO OXIDATIVO DE EFLUENTES CONTENDO HIDRAZINA

RONALD DA SILVA REIS 30 June 2004 (has links)
[pt] No Brasil está em larga expansão o uso de geração de eletricidade por termoeléctricas. Na geração de eletricidade por usinas térmicas são utilizados grandes quantidades de água e produtos químicos, que após utilização geram efluentes. A hidrazina é um produto químico usado para controle de corrosão em águas de caldeiras, sistemas de vapor e outros sistemas de usinas térmicas que após utilização acaba incorporada aos efluentes líquidos destas usinas. Com intuito de promover uma sistemática de controle de efluentes produzidos nas usinas, procurou-se, nesta dissertação, estudar efluentes contendo hidrazina com enfoque tecnológico. O processo abordado neste estudo consistiu no tratamento de efluentes contendo hidrazina, utilizando peróxido de hidrogênio com auxílio de catalisador de íons de cobre, para decomposição da hidrazina. Os ensaios foram feitos em laboratório, utilizando-se efluentes sintéticos com concentrações pré- determinadas de hidrazina que variaram entre 10 e 100 mg/L, com controle do pH que variou em 7 e 9,5, temperatura fixada em 220C, com adição de concentrações calculadas de peróxido de hidrogênio e catalisador de sulfato de cobre. Concluiu-se que o processo é viável para reduzir a concentração de hidrazina em efluentes a níveis inferiores aos limites da legislação (1 mg/L), utilizando-se quantidades estequiométricas de peróxido de hidrogênio em conjunto com sulfato de cobre em concentrações de 1 mg/L de Cu 2+ como catalisador, em efluentes com pH 9,5, a temperatura ambiente, em tempos inferiores a 30 minutos. Assim sendo, o trabalho mostrou-se adequado para satisfazer as condições de descarte de efluentes em águas brasileiras de acordo com a resolução CONAMA 20, carta P-031/01 cláusula 2 artigo V, de 9 de Fevereiro de 2001. / [en] In Brazil, the use of energy produced by power plant generators is in expansion. Power plants use large quantities of water and chemical products that after use end up in effluents. Hydrazine is used in water systems for corrosion control, because of its excelents oxygen scavenging capacity. The present work was conducted to study the treatment of effluents containing hydrazine, under a technological approach, with the purpose of contributing to a systematic of effluents control in power stations. The process studied in this work was the decomposition of hydrazine with hydrogen peroxid in presence catalyst cooper íon. The experiments were made in laboratory scale, using synthetic effluents with initial concentration of hydrazine at the levels 10 and 100 mg/L, with initial pH values 7 and 9,5, temperature fixed at 220C, with addition of st oichiometric amounts of hydrogen peroxide, with and without addition of cooper ion catalyst. It was conclued that the process its viable for reduction of hydrazine concentration in effluents with pH 9,5, below to levels under legislation (1mg/L), using stoichiometric amounts of hydrogen peroxide together with 1 mg/L of cooper ion, in times less that 30 minutes and ambient temperature. Therefore this work showed that the process is adequate in satisfying the Brazilian legislation for discharge of effluents into water bodies according to regulation CONAMA 20, letter P-031/01 clause 2 article V, 09 February 2001.
5

[en] ACCELERATED DEPURATION OF POLLUTED RIVERS USING HYDROGEN PEROXIDE / [pt] DEPURAÇÃO ACELERADA DE RIOS POLUÍDOS USANDO PERÓXIDO DE HIDROGÊNIO

NAIARA DE OLIVEIRA DOS SANTOS 05 July 2016 (has links)
[pt] Estudos prévios relacionam a ocorrência de episódios de mortandade de peixes em corpos hídricos como a Lagoa Rodrigo de Freitas (LRF) com a rápida disponibilização de espécies poluentes e nutrientes naturais na coluna d água especialmente durante altas precipitações de chuva, quando ocorre transbordo dos rios poluídos da bacia sobre a água da Lagoa, ocasionando uma demanda de oxigênio dissolvido maior do que o normal para depuração de tais espécies. Nesse contexto existe interesse em evitar episódios críticos de insuficiência de OD na água dos corpos hídricos que possam advir de tais eventos. Estudos realizados no presente trabalho tiveram como objetivo caracterizar as águas de rios da Sub-bacia hidrográfica da LRF através de DBO, COT, SST, Ptotal no canal a montante de deságue para a Lagoa em períodos de chuva e de tempo seco; e avaliar um possível tratamento que proporcione a depuração acelerada dos poluentes utilizando peróxido de hidrogênio, fornecendo oxigênio para as águas poluídas através do processo de decomposição do oxidante. Avaliaram-se diferentes dosagens de H2O2 em tempo reacional de 24h de acordo com limites de ecotoxicidade conhecidos. Testes realizados em amostras de rio coletadas em dias de baixa precipitação contendo concentrações de DBO de até 2,2 mg/L mostraram uma velocidade de decaimento de H2O2 inferior ao para amostras tanto coletadas também em dia de baixa precipitação porém com elevada DBO (24,0 mg/L), quanto para dia de alta precipitação (13,2 mm em 24 h) com relevante concentração de material orgânico. Observou-se uma dosagem suficiente de 15,0 mg/L para as amostras coletadas em baixa precipitação e alta DBO, e dosagem suficiente de 3,0 mg/L para amostras coletas em maior evento de precipitação (13,2 mm em 24 h), acima das quais, não ocorre mais aumento significativo da velocidade de decaimento da [H2O2] e também de velocidade de contribuição de OD para a água. Concluiu-se que a adição de H2O2 nas águas de rios durante eventos de poluição causados por chuvas intensas ou lançamento de esgoto pode contribuir para evitar episódios críticos de insuficiência de OD em rios poluídos por material orgânico e na pluma de poluentes que pode ser formada por transbordo dos rios para a LRF. / [en] Previous studies have associated the occurrence of episodes of death of fish in water bodies such as the Lagoa Rodrigo de Freitas (LRF) to to the rapid availability of pollutants and natural nutrients in the water column species especially during high rain precipitation events, which occur when the rivers overflow and pollute the water of the lagoon, causing a biochemical oxygen demand higher than usual for the rate of natural depuration of the contaminating species. In this context there is interest in avoiding critical episodes DO deficiency in the water bodies that may arise from such events. Studies conducted in the present work aimed at characterizing the rivers of sub-basin of LRF through BOD, TOC, TSS, Ptotal on the canal that overflows into the lagoon in periods of rain and dry weather; and evaluate a possible treatment offering the accelerated depuration of pollutants using hydrogen peroxide, providing oxygen to the polluted water through the self-decomposition process. The study evaluated the effect of different doses H2O2 in 24 hours of reaction time according to known ecotoxicity limits. In tests on samples collected from rivers in days of little rain containing BOD concentrations up to 2.2 mg / L, H2O2 showed a decay rate lower than those of other samples also collected on days of low precipitation, but with high BOD (24, 0 mg / L), and days of high rainfall (24 hours 13.2 mm), with a significant concentration of dissolved organic contaminants. A maximum sufficient dose of 15.0 mg / L was found for the low and high samples precipitation BOD, and a maximum sufficient dose of 3.0 mg / L for most of the samples collected during the precipitation event (13.2 mm 24 hours), above which there is no significant increase over the rate of decomposition of [H2O2], and the rate of generation of DO in the water. It was concluded that the addition of H2O2 into the waters of rivers during pollution events caused by heavy rains or sewage release can help to avoid critical episodes of DO deficiency in polluted rivers by organic matter and pollutant plume that can be formed by overflow of those rivers to the LRF lagoon.
6

[en] TREATMENT OF EFFLUENTS CONTAINING FREE CYANIDE THROUGH THE SYSTEM H2O2/UV / [pt] TRATAMENTO DE EFLUENTES CONTENDO CIANETO LIVRE ATRAVÉS DO SISTEMA H2O2/UV

ADRIANA CINOPOLI GONCALVES 10 March 2005 (has links)
[pt] O presente trabalho teve como objetivo estudar o tratamento de efluentes contendo cianeto livre através do sistema H2O2/UV e selecionar as condições operacionais mais adequadas para uma maior eficiência do processo. Para isso, foram empregadas soluções sintéticas de KCN com características de pH e concentração similares às condições de um efluente industrial real. O fotorreator utilizado nos testes de oxidação foi um reator cilíndrico de seção anular, equipado com uma lâmpada de baixa pressão de 28 W concêntrica com emissão em 254 nm, onde a solução ficava diretamente em contato com a mesma. Este fotorreator foi acoplado a um sistema de refrigeração que mantinha a temperatura de operação em 25oC.As variáveis avaliadas foram concentração inicial de cianeto em solução, pH inicial da solução, potência de UV irradiada e razão molar [H2O2]/[CN-]. Para soluções contendo uma concentração inicial de cianeto igual a 100 ppm, foi possível atingir uma eficiência remoção de 99,9 por cento em 25 minutos, em pH igual a 9,5, com uma razão molar [H2O2]:[CN-] igual a 3. Para efluentes contendo uma concentração inicial de cianeto igual a 300 ppm, nas mesmas condições operacionais, alcançou-se a mesma eficiência em 30 minutos. / [en] The present work had the objective of studying the treatment of effluents containing free cyanide through the system H2O2/UV, and of selecting the best operational conditions for best efficiency of the process. For that, it was employed synthetic solutions of KCN with characteristics of pH and concentration similar to those of a real effluent. The photoreactor employed in the oxidation tests was a cylindrical reactor of annular section, equipped with a concentrical low pressure lamp of 28 W with emission in 254 nm, where the solution was in direct contact with the lamp. This photoreactor was coupled with a cooling system which kept the operation temperature at 25oC. The evaluated variables were initial cyanide concentration in solution, initial pH of the solution, power of radiated UV and molar ratio [H2O2]/[CN-]. For solutions containing an initial concentration of cyanide equal to 100 ppm, it was possible to reach a removal efficiency of 99.9 per cent in 25 minutes, in pH equal to 9.5, with a molar ratio of [H2O2]:[CN-] equal to 3. For effluents containing an initial concentration of cyanide equal to 300 ppm, at the same operational conditions, it was possible to achieve the same removal efficiency in 30 minutes.
7

[en] PRODUCED WATER TREATMENT IN OIL AND GAS EXTRACTION BY ADVANCED OXIDATION / [pt] TRATAMENTO DE ÁGUA PRODUZIDA NA EXTRAÇÃO DE PETRÓLEO E GÁS POR OXIDAÇÃO AVANÇADA

FERNANDA MCCOMB DE OLIVEIRA 02 September 2024 (has links)
[pt] Água produzida (AP) é uma das fases geradas a partir da separação trifásica obtida após a extração do petróleo e gás e constitui um efluente industrial. O gerenciamento do seu tratamento para descarte face a alta vazão típica e sensibilidade dos ecossistemas marinhos, é um desafio para empresas que lidam com este tipo de fluido, principalmente na extração offshore. Como este efluente tem uma composição química complexa e variável chegando em até 500 mg/L de compostos orgânicos solúveis em água (WSO), os quais não são facilmente removidos pelos tratamentos físico-químicos convencionais como coagulação e floculação, diversas alternativas de tratamento são adotadas a fim de conseguir eliminar ao máximo óleos e micropartículas de sólidos presentes. Para tal, a AP deve ser tratada antes de ser lançada ao mar ou reutilizada no processo. Contudo, nem sempre as etapas do tratamento conseguem funcionar de maneira ótima para atender a qualidade ambiental regulatória, de modo que a busca por novos processos de tratamento segue sendo de interesse geral. Neste trabalho foram testados processos de oxidação catalisada com íons Fe para incrementar a degradação de WSO, usando amostras reais de AP da Bacia de Campos (RJ, Brasil). Os melhores resultados foram obtidos nas seguintes condições de H2O2 em dose de 1x sem necessidade de catalisador (Fe2+). Nessas ocorreu uma redução de 66 por cento dos orgânicos solúveis, suficiente para manter conformidade com as exigências das normas ambientais para descarte de AP no mar. / [en] Produced water (PW) is one of the phases generated from the three-phase separation obtained after the extraction of oil and gas and constitutes an industrial effluent. The management of its treatment for disposal due to the typical high flow and sensitivity of marine ecosystems is a challenge for companies that deal with this type of fluid, especially in offshore extraction. Since this effluent has a complex and variable chemical composition reaching up to 500 mg/L of water-soluble organic compounds (WSO), which are not easily removed by conventional physicochemical treatments such as coagulation and flocculation, several treatment alternatives are adopted in order to eliminate as much as possible oils and microparticles of solids present. To reach this goal, the PW must be treated before being released into the sea or reused in the process. However, the treatment stages are not always able to function optimally to meet the regulatory environmental quality, so the studies for new treatment processes continues to be part of general interest. In this work, Fe ion-catalyzed oxidation processes were tested to increase WSO degradation, using real PW samples from the Campos Basin (RJ, Brazil). The best results were obtained under the following conditions of H2O2 at a dose of 1x without the need for catalyst (Fe2+). In these, there was a 66 percent reduction in soluble organics, sufficient to maintain compliance with the requirements of environmental standards for water discharge.
8

[en] REMOVAL OF MANGANESE FROM WATERS AND INDUSTRIAL EFFLUENTS WITH USE OF HYDROGEN PEROXIDE / [pt] REMOÇÃO DE MANGANÊS DE ÁGUAS E EFLUENTES INDUSTRIAIS COM UTILIZAÇÃO DO PERÓXIDO DE HIDROGÊNIO

JULIANA SANTOS DOS SANTOS 07 April 2005 (has links)
[pt] Para remover metais de águas e efluentes aquosos, geralmente são empregados métodos tradicionais, os quais envolvem a neutralização, com posterior hidrólise e precipitação de hidróxidos, utilizando uma base.O manganês deve ser removido de águas e efluentes aquosos, até que sua concentração atinja um máximo exigido pela legislação brasileira, que é de 0,1mg/L para águas e 1mg/L para efluentes aquosos. O trabalho desenvolvido aqui investigou a remoção de manganês (II) utilizando os oxidantes: oxigênio, reagente Fenton e peróxido de hidrogênio, para procurar dentre estes um processo que fosse mais eficiente do que o de simples precipitação do hidróxido. São discutidos os resultados de ensaios realizados com a utilização de soluções sintéticas de manganês (II), cujo objetivo foi desenvolver um caminho que favorecesse a remoção deste metal, para que a concentração do mesmo tanto em águas quanto em efluentes aquosos esteja de acordo com os padrões exigidos pela legislação brasileira (resolução CONAMA 20/ 1986).Os ensaios foram realizados em pH de 7 a 10, a temperatura ambiente e em torno de 80ºC e com um tempo de reação de 5,15 e 30 minutos. Foi utilizado peróxido de hidrogênio em dosagem estequiométrica com excesso de 100% e 200%, para a reação: Mn2+ (aq) + H2O2 (aq) -> MnO2(s) + 2 H+ (aq) Dentre os testes realizados, ambos o peróxido de hidrogênio e o reagente Fenton mostraram-se bastante eficientes na remoção de manganês, permitindo atingir concentrações finais desse metal inferiores a 0,3 mg/L, a temperatura ambiente em valores de pH inferiores aos necessários para a precipitação sem oxidante, com O2. / [en] I order to remove metals from waters and aqueous effluents generally are employed traditional methods which involve neutralization, hydrolysis and precipitation of hydroxides using a base. Manganese must be removed from waters and aqueous effluents down to a concentration limited by Brazilian law which is of 0.1 mg/L for waters and 1.0 mg/L for aqueous effluents. The work carried out herein investigated the removal of manganese (II) using the following oxidants: oxygen, hydrogen peroxide, and Fenton reagent, with the aim to identify a process that could be more efficient than the simpler hydroxide precipitation. Results are discussed of experiments made with synthetic solutions of 1000 mg/L manganese (II) with the objective of developing a route that could favour the removal of that metal to the levels established by Brazilian environmental law (resolution CONAMA 20 / 1986).The experiments were conducted in pH 7 to 10, at temperature ambient and 80 oC, with reaction times of 5, 15 and 30 minutes. Hydrogen peroxide was used in excess levels of 100 and 200% for the reaction: Mn2+ (aq) + H2O2 (aq) -> MnO2 (s) + 2 H+ (aq) Amongst the conducted experiments, both hydrogen peroxide and the Fenton reagent were shown to be most effective, allowing final concentrations of manganese less than 0.3 mg/L, at ambient temperature, in pH values lower than those required for precipitation without oxidation or with O2 (air).
9

[en] OPTIMIZATION OF THE PARAMETERS OF DELIGNIFICATION OF SUGARCANE BAGASSE WITH ALKALINE HYDROGEN PEROXIDE THROUGH NEURAL MODEL / [pt] OTIMIZAÇÃO DOS PARÂMETROS DA DESLIGINIZAÇÃO DO BAGAÇO DE CANA-DE-AÇÚCAR COM PERÓXIDO DE HIDROGÊNIO ALCALINO ATRAVÉS DE MODELO NEURAL

ARTUR SERPA DE CARVALHO REGO 22 May 2018 (has links)
[pt] O Brasil é o maior produtor de cana-de-açúcar do mundo, produzindo a maior quantidade de resíduo em forma de bagaço, que atualmente é queimado na indústria para geração de energia elétrica, apesar de ainda possuir potencial para produzir outros compostos de maior valor agregado, como etanol de segunda geração, ácido lático, butanodiol e etc. Neste trabalho, foi avaliado o desempenho do pré-tratamento do bagaço de cana-de-açúcar utilizando peróxido de hidrogênio em meio alcalino. Com o intuito de retirar a lignina para liberar os carboidratos no meio, foram realizados experimentos variando a temperatura (25 graus Celsius – 45 graus Celsius) e concentração de peróxido de hidrogênio (1,5 por cento - 7,5 por cento) a pH 11,5 por 1 h em um shaker orbital a 100 rpm. O desempenho do pré-tratamento foi medido utilizando o método gravimétrico de Klason para quantificar a lignina, o HPLC para determinar as concentrações de xilose e glicose e o infravermelho para determinar mudanças na estrutura da biomassa. A análise de Klason indicou 45 graus Celsius /7,5 por cento como melhor condição de solubilização, com 75,4 por cento de solubilização, as análises de HPLC indicaram 45 graus Celsius/7,5 por cento como melhor condição para a obtenção de glicose com concentração de 1,66 g/L e 25 graus Celsius/7,5 por cento para obtenção de xilose com concentração de 0,82 g/L e as análises de FT-IR indicaram 25 graus Celsius /1,5 por cento como melhor condição de oxidação, com 66,9 por cento de oxidação de lignina. Para cada análise, foi proposto um modelo de rede neural artificial. A rede das análises de Klason teve a topologia trainlm/logsig/4 com SSE 0,00723 e R2 0,995, a rede das análises de glicose teve topologia trainlm/logsig/4 com SSE 0,0328 e R2 0,97384, a rede das análises de xilose teve topologia trainlm/logsig/5 com SSE 0,289 e R2 0,87441 e a rede das análises de FT-IR teve topologia trainlm/logsig/5 com SSE 0,0316 e R2 0,98414. / [en] Brazil leads the world in sugarcane production, consequently produces also the greatest amount of sugarcane bagasse. Currently, this sugarcane bagasse is leveraged for power generation in the mills, but this biomass still has a potential for production of others value-added compounds such as the second-generation ethanol, lactic acid, butanediol and etc. The present work was carried out in order to study the efficiency of the delignification process of sugarcane bagasse with alkaline hydrogen peroxide. Two variable were assessed experimentally: temperature (25 Celsius degrees - 45 Celsius degrees) and H2O2 concentration (1.5 percent -7.5 percent) at pH 11.5 for 1 h in an orbital shaker at 100 rpm. The Klason Method was used to measure concentration of extracted lignin, HPLC was used to measure the concentration of glucose and xylose and FT-IR analysis was applied to identify lignin structure in the samples. The Klason analysis indicated the 45 Celsius degrees/7,5 percent as the optimum condition with 75,4 percent of the lignin solubilidized, the glucose analysis indicated 45 Celsius degrees/7,5 percent as the optimum condition with a concentration of 1,66 g/L, the xylose analysis indicated 25 Celsius degrees/7,5 percent as the optimum condition with a concentration of 0,82 g/L, and the FT-IR analysis indicated 25 Celsius degrees/1,5 percent as the optimum condition with 66,9 percent of the lignin oxidized. For each analysis, an ANN model was proposed. The network of the Klason analysis had a trainlm/logsig/4 topology with SSE 0,00723 and R2 0,995, the network of the glucose analysis had a trainlm/logsig/4 topology with SSE 0,0328 and R2 0,97384, the network of the xylose analysis had a trainlm/logsig/5 topology with SSE 0,289 and R2 0,87441, the network of the FT-IR analysis had a trainlm/logsig/5 topology with SSE 0,0316 and R2 0,98414.
10

[pt] OTIMIZAÇÃO DE PROCESSO PARA PRODUÇÃO DO COAGULANTE SULFATO FÉRRICO PELA OXIDAÇÃO DE SULFATO FERROSO COM PERÓXIDO DE HIDROGÊNIO / [en] PROCESS OPTIMIZATION FOR THE PRODUCTION OF FERRIC SULFATE COAGULANT BY THE OXIDATION OF FERROUS SULFATE WITH HYDROGEN PEROXIDE

VERONICA BARBOSA MAZZA 25 March 2020 (has links)
[pt] Sabe-se que o coagulante sulfato férrico pode ser obtido através da reação de oxidação entre sulfato ferroso e peróxido de hidrogênio em meio ácido. Porém, o método conhecido de obtenção deste coagulante em escala industrial utilizando o peróxido de hidrogênio como agente oxidante não proporciona condições economicamente atrativas, frente aos demais processos. Este potente agente oxidante sofre forte influência da temperatura e da presença de íons ferro no seu processo de auto decomposição em água e oxigênio. Pode-se considerar que as condições do meio reacional, na etapa de adição do agente oxidante, são os fatores determinantes para a produção do coagulante férrico com o maior aproveitamento do peróxido de hidrogênio adicionado. O presente trabalho teve como objetivo investigar as condições necessárias para a produção do coagulante férrico utilizando o peróxido de hidrogênio, em um processo economicamente competitivo. A pesquisa foi fundamentada nas técnicas de planejamento de experimentos e otimização de processos. A modelagem matemática do processo possibilitou a definição da magnitude dos parâmetros a serem utilizados otimizando o processo e a especificação das características desejadas do produto final. As variáveis independentes estudadas na modelagem matemática foram: temperatura (7,5 – 27,5 graus celsius), quantidade de peróxido de hidrogênio (100 – 300 porcento) referente à sua quantidade estequiométrica e a diluição do meio utilizando água (100 – 300 porcento) referente à sua quantidade estequiométrica. As quantidades estequiométricas dos reagentes foram determinadas visando ao atingimento das especificações de um coagulante férrico comercial. O modelo desenvolvido foi sobre a Conversão de Fe2(+) em Fe3(+) (porcento) e avaliado através da Análise da Variância (ANOVA). As condições ótimas escolhidas para o ponto ótimo foram: temperatura igual a 17,5 graus celsius, 150 porcento da quantidade estequiométrica de peróxido de hidrogênio e 200 porcento da quantidade estequiométrica de água. A resposta da etapa de otimização indicou uma conversão de 96,17 porcento de Fe2(+) em Fe3(+), resultando em um coagulante dentro dos padrões especificados por norma técnica. O modelo matemático obtido previu uma conversão de 96,13 porcento de Fe2(+) em Fe3(+), resultando em um erro percentual de 0,043 porcento entre o resultado predito pelo modelo matemático e o resultado experimental. As análises das superfícies de resposta e da quantidade de peróxido de hidrogênio residual em solução indicaram que o controle do processo em baixas temperaturas contribui para o melhor aproveitamento do peróxido de hidrogênio na conversão de Fe2(+) em Fe3(+), devido à desaceleração da auto decomposição incitada pelo fator temperatura. A análise do potencial de redução ao longo da reação em função do perfil de conversão mostrou que conversões acima de 90 porcento de Fe2(+) em Fe3(+) apresentaram potencial redox (Eh) correspondente acima de 0,70 Volts, indicando a possibilidade da utilização deste parâmetro no controle da conversão em processos industriais. / [en] It is known that the coagulant ferric sulfate can be obtained by the oxidation reaction of ferrous sulfate with hydrogen peroxide in acidic medium. However, the known method of obtaining this coagulant on an industrial scale using hydrogen peroxide as an oxidizing agent do not provide economically attractive conditions compared to other processes. This potent oxidizing agent undergoes strong influence of the temperature and the presence of iron ions in its process of self-decomposition in water and oxygen. It can be considered that the conditions of the reaction medium in the step of adding the oxidizing agent are the determining factors for the production of the ferric coagulant with the greatest use of the added hydrogen peroxide. The present work had the objective of investigating the necessary conditions for the production of the ferric coagulant using the hydrogen peroxide as an economically competitive process. The research was based on the techniques of factorial design and process optimization. The mathematical modeling of the process allowed the definition of the magnitude of the parameters to be used, optimizing the process and specifying the desired characteristics of the final product. The independent variables studied in the mathematical modeling were: temperature (7,5 – 27,5 celsius degrees), amount of hydrogen peroxide (100-300 percent) relative to its stoichiometric amount, and dilution of the medium using water (100-300 percent) relative to its stoichiometric amount. The stoichiometric quantities of the reactants were determined in order to reach the specifications of a commercial ferric coagulant. The model developed was on Conversion of Fe2(+) to Fe3(+) (percent) and evaluated through Analysis of Variance (ANOVA). The optimum conditions chosen for the optimum were: temperature equal to 17,5 Celsius degrees, 150 percent of the stoichiometric amount of hydrogen peroxide and 200 percent of the stoichiometric amount of water. The optimization of the response surfaces indicated a conversion of 96.17 percent Fe2(+) to Fe3(+), resulting in a coagulant within the characteristics specified by the technical standard. The obtained mathematical model predicted a conversion of 96.13 percent Fe2(+) to Fe3(+), resulting in a percentage error of 0,043 percent between the predicted results by the mathematical model and the experimental results. The analysis of the response surfaces and the amount of residual hydrogen peroxide in solution indicated that the control of the process at low temperatures contributes to the better utilization of the hydrogen peroxide in the conversion of Fe2(+) into Fe3(+), due to the deceleration of the self-induced decomposition by the factor temperature. The analysis of the reduction potential along the conversion profile function showed that conversions above 90 percent of Fe2(+)into Fe3(+) presented a corresponding redox potential (Eh) above 0,70 Volts, indicating the possibility of using this parameter for the control of conversion into industrial processes.

Page generated in 0.0348 seconds