• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 133
  • 133
  • 62
  • 52
  • 34
  • 26
  • 26
  • 25
  • 22
  • 19
  • 17
  • 16
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Adsorção de antibióticos em meio aquoso utilizando diferentes adsorventes /

Silva, Niléia Cristina da. January 2015 (has links)
Orientador: Newton Luiz Dias Filho / Banca: Devaney Ribeiro do Carmo / Banca: Marcio José Tiera / Banca: Vitor de Cinque Almeida / Banca: Affonso Celso Gonçalves Junior / Resumo: A presença de compostos farmacológicos nos mananciais de abastecimento representa um comprometimento à qualidade das águas destinadas ao consumo humano. A introdução destes compostos no meio ambiente através de fontes antropogênicas constitui um risco latente para os organismos aquáticos e terrestres. Alguns estudos reportam para a reduzida efetividade na remoção dos fármacos presentes na água bruta durante seu tratamento em uma Estação de Tratamento. Diante deste tema, o presente estudo avaliou a capacidade de remoção dos antibióticos ampicilina, amoxicilina, cefalexina e ciprofloxacina, via processo de adsorção em batelada e coluna, utilizando seguintes adsorventes: PET (pós uso), bagaço de cana-de- açúcar (BCA), argila funcionalizada com N-dodecil-2-pirrolidona (Mo-DDP), sílica e oligômero poliédrico de silsesquioxano organomodificado com tiouréia (SG-TU e POSS-TU, respectivamente) e ciclodextrina modificada com sílica (β-CDSi). Os adsorventes foram caracterizados por titulação de Boehm, FTIR, pH de ponto de carga zero (pH PCZ ) e MEV. As concentrações dos fármacos foram determinadas por cromatografia líquida de alta eficiência. Os parâmetros de adsorção testados mostraram que de 120 a 240 min. de contato são suficientes para a adsorção dos adsorvatos nos adsorventes e que o pH inicial da solução interfere na adsorção em magnitudes diferentes, dependendo do sistema adsorvente-adsorvato avaliado. O equilíbrio da adsorção em batelada foi expresso por meio de isotermas de adsorção de acordo com os modelos de Langmuir, Freundlich, Temkin e D-R. A isoterma Freundlich foi a que melhor representou os dados experimentais para todos os adsorventes, exceto para β-CDSi, que teve o equilíbrio de adsorção melhor representado pelo modelo de Langmuir. A cinética de adsorção dos fármacos foi discutida utilizando os modelos cinéticos de Pseudo- primeira e... / Abstract: The presence of pharmacological compounds in water supply sources are a risk as to the quality of water intended for human consumption. The introduction of these compounds into the environment through anthropogenic sources is a latent risk to aquatic and terrestrial organisms. Some studies report to reduced effectiveness in removing the drugs present in raw water during its treatment in a Water Treatment Plant. Given this aspect, the present study evaluated the removal capacity of antibiotics ampicillin, amoxicillin, cephalexin and ciprofloxacin, via adsorption process in batch and column using the following adsorbents: plastic bottles (after use), sugar cane bagasse (SCB), functionalized clay with N-dodecyl-2- pyrrolidone (Mo-DDP), silica and oligomer polyhedral of organo silsesquioxane modified with thiourea (SG- TU and POSS-TU, respectively), and silica modified by cyclodextrin (β- CDSi). The adsorbents were characterized by Boehm titration, FTIR, pH zero point of charge (pH ZPC ) and SEM. The drug concentrations were determined by high performance liquid chromatography. The adsorption parameters tested showed that 120‟ to 240‟ of contact are sufficient for adsorbent adsorption in the adsorbents which the solution initial pH interferes in the adsorption in different magnitudes, depending on the adsorbent-adsorbate system rated. The adsorption balance batched was expressed through isotherms adsorption according to Langmuir, Freundlich, Temkin and D-R. The Freundlich isotherm was the one that best represented the experimental data for all adsorbents, except for β-CDSi, which had the best adsorption equilibrium represented by the Langmuir model. The kinetics of drugs adsorption was discussed using the kinetic models of Pseudo-first and second order, Elovich, intraparticle diffusion and film diffusion. The Pseudo-second kinetic model can better describe the adsorption of antibiotics in the ... / Doutor
42

Estudo hidrodinâmico de floculadores mecanizados aplicados ao tratamento de água /

Cestari, Jesus Leonardo. January 2011 (has links)
Resumo: Utilizando-se um floculador mecanizado com quatro câmaras foram realizados ensaios hidrodinâmicos com o traçador cloreto de sódio obtendo-se curvas de distribuição dos tempos de residência (DTR) e os tempos de residência médios para os tempos de residência teórico de 29,54 min, 22,15 min e 14,77 min respectivamente para o floculador operando com 04, 03 e 02 câmaras. Entre as câmaras de floculação havia quatro diferentes posições de passagens, sendo duas em cima "D" e "E" (respectivamente Direita superior e Esquerda superior) e duas embaixo "d" e "e" (respectivamente direita inferior e esquerda inferior). Levando-se em consideração que a entrada de água era realizada na passagem "e", foram combinadas quatro configurações de passagem para floculador de 04 câmaras (eEeEe , eDeDe , edede e eeeee) e uma quinta empregando-se anteparos (e/e/e/e/e). As mesmas configurações foram estendidas ao floculador operando com 03 e 02 câmaras. Procurou-se avaliar nos floculadores, operando sob as diferentes configurações de passagem apresentadas acima, a magnitude dos efeitos dos curtos-circuitos de acordo com os estudos pré- definidos. Tais estudos combinaram o sentido de rotação dos agitadores (sentido alternado e mesmo sentido de rotação ao longo das câmaras) com a constância ou a variação do gradiente de floculação, além de um estudo com os agitadores desligados. Observou-se, após a análise das curvas DTR, que as configurações edede e e/e/e/e/e para floculador de 04 câmaras, estendidas aos floculadores de 03 e 02 câmaras, apresentaram menor incidência de curtos-circuitos que a configuração eEeEe. A colocação do anteparo que gerou a configuração e/e/e/e/e para floculador de 04 câmaras, estendida aos floculadores de 03 e 02 câmaras, mostrou-se uma alternativa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Using a mechanical flocculator with four flocculation chambers, hydrodynamic tests were conducted using sodium chloride as a tracer resulting in curves of the residence time distribution (RTD) and the mean residence times for the theoretical residence time of 29.54 min, 22.15 min and 14.77 minutes, respectively for the flocculator with 04, 03 and 02 chambers. Between the flocculation chambers had four different positions of passages, two on top "D" and "E" (respectively upper right and upper left) and two down "d" and "e" (respectively lower right and lower left). Taking into account that the entry of water has always been held in the lower left passage "e" for the flocculator with 04 chambers, four different configurations were combined (eEeEe, eDeDe, edede and eeeee) and a fifth employing shields (e/e/e/e/e). The same settings were extended to the flocculator operating with three and two chambers. Was evaluated in flocculation unit, operating under the different configurations of passage, the magnitude of the effects of short circuits according to the studies previously defined. These studies combined the direction of rotation of the agitator with the velocity gradient and a study of the rioters off. Was observed after analysis of the curves RTD, that the settings edede and e/e/e/e/e to flocculators of 04, 03 and 02 chambers, showed a lower incidence of short-circuits that configuration eEeEe. The placement of the bulkhead, which generated the configuration e/e/e/e/e, showcases itself as an efficient alternative only in the absence of agitation, promoted by agitators. Flocculator with 04 chambers, one does not notice the influence of parameters direction of the agitator and the constancy or variation of velocity gradient on the RTD / Orientador: Marcelo Libânio / Coorientador: Tsunao Matsumoto / Banca: Milton Dall'Aglio Sobrinho / Banca: Luiz Di Bernardo / Mestre
43

Avaliação dos processos oxidativos UV/H2O2 e UV/PAA na degradação de matéria orgânica natural e 2-MIB/geosmina em água de abastecimento

Souza, Fernanda Scuissiatto Mares de 26 October 2012 (has links)
O cloro é o agente desinfetante e oxidante mais utilizado no mundo em sistemas de tratamento de água. Entretanto, a aplicação de cloro em águas superdiciais pode levar a formação de subprodutos de desinfecção, além da ineficiência do oxidante na degradação de micropoluentes. Este trabalho teve como objetivo avaliar a eficiência dos agentes peroxidados, peróxido de hidrogênio (H2)2) e ácidoperacético (PAA), em processo oxidativo avançado (POA) Assistido por UVC, na degradação de matéria orgânica natural e 2-MIB e geosmina em água de abastecimento. A matriz utilizada foi água do Rio Iratí, amostra na região metropolitana de Curitiba/PR. Como pré-tratamento da água, foram abordadas as etapas de coagulação, floculação, sedimentação e filtração com o agente coagulante PAC. Os POAs doram realizados em reatores UVC com lâmpadas de baixa pressão, em modo batelada e modo contímuo. No tratamento UV/H2O2, eficiência máxima de redução nos valores de UVA254 (92%) e fluorescência (95%), foram obtidas em modo contínuo após 15 minutos reacionais e 15 mg.L­­-¹ de H2)2, na ausência de 2-MIB/geosmina. A formação de TTHM foi reduzida, situando-se em 15,7 ÞL-¹ . A degradação dos contaminantes 2-MIB e geosmina, após prétratamento e processo UV/H2O2, resultou em teores à 0,1 þg.L-¹. A presença do solvente metanol nos contaminantes-padrão foi considerada como fator interferente negativo ao processo UV/H2O2. No tratamento UV/PAA, verificou-se a contribuição negativa de CODNP inerente ao próprio oxidante. No entanto o processo foi eficiente em até 89% na redução de intensidade de fluorescência, com formação de 21,5 þg.L-¹ de TTHM. A análise experimental indicou efeito positivo e significativo para a variável tempo de resistência em todos os ensaios e POAs realizados. Em nenhum dos ensaios foi possível obter a mineralização total do conteúdo carbônico presente nas amostragens. Os tratamentos UV/H2O2 e UV?PAA apresentaram um perfil de resposta não-linear, sendo necessários ajustes para o enquadramento em modelo quadrático. / As a disinfectant and an oxidizing agent, chlorine is the most used chemical in various water may lead the formation of desinfection byproducts, furthermore, the inefficiency on micropollutants degradation. the main purpose of this work is to evaluate the efficiency of hydrogen peroxide (H2O2) and peracetic acid (PAA), in advanced oxidation process under UVC radiation, on degradation of natural organic matter and contaminats 2-MIB/geosmin in supplying water. The environmental matrix involved was water from Iratí River, located near Curitiba/PR. Waterpretreatment included coagulation, floculation and sedimentation operations at jar test equipement, with PAC as coagulant agent. Advanced oxidative treatments were executed at UV reactors, with low-pressure lamps, in batch and continuous mode. in UV?H@O@ treatment, maximum efficiency on UVA254 reduction (92%) and fluorescence (95%), was obtained in continuos flowing mode, after 15 minutes (reaction taime) and 15 mg.L-¹ of hydrogen peroxide, in the absence of 2-MIB and geosmin. The formation of total trihalomethanes was one of the lowest at 15.7 þg.L-¹. Degradation of pollutants 2-MIB and geosmin, after pretreatment and AOP UV/H2O2, ended in concentrations lower than 0.1 þg.L-1. According to these UV/H2O2 tests, certain reduction was obsorved at efficiency results of all response factors monitored, since the presence of methanol intrinsic to the contaminat standard solution applied. In UV/PAA, was noticed some contribution of NPDOC provided by the own oxidizing agent (PAA). However, UV/PAA treatment was efficient at 89% according to fluorescence intensity reduction, associated with the formation of total trihalomethanes at 21,5 þg.L-¹. Experimental analysis indicated positive and significant effect for the variable retention time in all tests. None of the tests resulted in carbon complete mineralization. Treatment with UV/H2O2 and Uv/PAA presented non-linear response profile, being necessary adjustments for quadratic fitting.
44

Avaliação dos processos oxidativos UV/H2O2 e UV/PAA na degradação de matéria orgânica natural e 2-MIB/geosmina em água de abastecimento

Souza, Fernanda Scuissiatto Mares de 26 October 2012 (has links)
O cloro é o agente desinfetante e oxidante mais utilizado no mundo em sistemas de tratamento de água. Entretanto, a aplicação de cloro em águas superdiciais pode levar a formação de subprodutos de desinfecção, além da ineficiência do oxidante na degradação de micropoluentes. Este trabalho teve como objetivo avaliar a eficiência dos agentes peroxidados, peróxido de hidrogênio (H2)2) e ácidoperacético (PAA), em processo oxidativo avançado (POA) Assistido por UVC, na degradação de matéria orgânica natural e 2-MIB e geosmina em água de abastecimento. A matriz utilizada foi água do Rio Iratí, amostra na região metropolitana de Curitiba/PR. Como pré-tratamento da água, foram abordadas as etapas de coagulação, floculação, sedimentação e filtração com o agente coagulante PAC. Os POAs doram realizados em reatores UVC com lâmpadas de baixa pressão, em modo batelada e modo contímuo. No tratamento UV/H2O2, eficiência máxima de redução nos valores de UVA254 (92%) e fluorescência (95%), foram obtidas em modo contínuo após 15 minutos reacionais e 15 mg.L­­-¹ de H2)2, na ausência de 2-MIB/geosmina. A formação de TTHM foi reduzida, situando-se em 15,7 ÞL-¹ . A degradação dos contaminantes 2-MIB e geosmina, após prétratamento e processo UV/H2O2, resultou em teores à 0,1 þg.L-¹. A presença do solvente metanol nos contaminantes-padrão foi considerada como fator interferente negativo ao processo UV/H2O2. No tratamento UV/PAA, verificou-se a contribuição negativa de CODNP inerente ao próprio oxidante. No entanto o processo foi eficiente em até 89% na redução de intensidade de fluorescência, com formação de 21,5 þg.L-¹ de TTHM. A análise experimental indicou efeito positivo e significativo para a variável tempo de resistência em todos os ensaios e POAs realizados. Em nenhum dos ensaios foi possível obter a mineralização total do conteúdo carbônico presente nas amostragens. Os tratamentos UV/H2O2 e UV?PAA apresentaram um perfil de resposta não-linear, sendo necessários ajustes para o enquadramento em modelo quadrático. / As a disinfectant and an oxidizing agent, chlorine is the most used chemical in various water may lead the formation of desinfection byproducts, furthermore, the inefficiency on micropollutants degradation. the main purpose of this work is to evaluate the efficiency of hydrogen peroxide (H2O2) and peracetic acid (PAA), in advanced oxidation process under UVC radiation, on degradation of natural organic matter and contaminats 2-MIB/geosmin in supplying water. The environmental matrix involved was water from Iratí River, located near Curitiba/PR. Waterpretreatment included coagulation, floculation and sedimentation operations at jar test equipement, with PAC as coagulant agent. Advanced oxidative treatments were executed at UV reactors, with low-pressure lamps, in batch and continuous mode. in UV?H@O@ treatment, maximum efficiency on UVA254 reduction (92%) and fluorescence (95%), was obtained in continuos flowing mode, after 15 minutes (reaction taime) and 15 mg.L-¹ of hydrogen peroxide, in the absence of 2-MIB and geosmin. The formation of total trihalomethanes was one of the lowest at 15.7 þg.L-¹. Degradation of pollutants 2-MIB and geosmin, after pretreatment and AOP UV/H2O2, ended in concentrations lower than 0.1 þg.L-1. According to these UV/H2O2 tests, certain reduction was obsorved at efficiency results of all response factors monitored, since the presence of methanol intrinsic to the contaminat standard solution applied. In UV/PAA, was noticed some contribution of NPDOC provided by the own oxidizing agent (PAA). However, UV/PAA treatment was efficient at 89% according to fluorescence intensity reduction, associated with the formation of total trihalomethanes at 21,5 þg.L-¹. Experimental analysis indicated positive and significant effect for the variable retention time in all tests. None of the tests resulted in carbon complete mineralization. Treatment with UV/H2O2 and Uv/PAA presented non-linear response profile, being necessary adjustments for quadratic fitting.
45

Água tratada : formação de trialometanos pelo uso do cloro e os riscos potenciais à saúde pública em cidades da mesorregião do leste rondoniense

Leão, Vonivaldo Gonçalves January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Fernanda Weschenfelder (nandaweschenfelder@gmail.com) on 2009-10-01T16:37:34Z No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2010-02-12T22:44:01Z (GMT) No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) / Made available in DSpace on 2010-02-12T22:44:01Z (GMT). No. of bitstreams: 1 2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) Previous issue date: 2008 / Nos sistemas de abastecimento de água potável é comum o uso do cloro e de seus derivados. O poder de oxidação do cloro livre sobre bactérias reduz e protege a água contra as proliferações de microorganismos. A mesorregião leste do estado de Rondônia, composta pelos municípios Cacoal, Ji-Paraná, Espigão d’Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d’Oeste, Ministro Andreazza e Presidente Médici que fizeram parte do estudo desta dissertação, é caracterizada pela presença de rios que servem como captação de água a ser tratada e fornecida à população. Devido a vários estudos realizados com relação à presença de contaminantes químicos formados após a cloração da água, principalmente a formação de trialometanos, estudos estes que procuram correlacionar a possibilidade destes compostos serem carcinogênicos e mutagênicos, neste trabalho foram analisados os níveis de trialometanos formados nas estações de tratamento de água. As amostras foram coletadas em épocas sazonais e os resultados demonstraram a existência de pontos críticos quanto à formação de trialometanos, dentre eles alguns possíveis motivos são: em Ji-Paraná a água bruta contendo contaminação de trialometanos, principalmente diclorometano, e também a disposição dos equipamentos, provocando um maior contato do cloro livre com substâncias orgânicas. Em Alta Floresta d’Oeste a precariedade nos decantadores e filtros que não condiz com a vazão de tratamento. De acordo com este estudo em épocas chuvosas há diminuição dos níveis de trialometanos, diferentes dos apresentados em estudos em outras localidades. Há a possibilidade das características do solo na região de estudo influenciar e fazer com que haja diluição do leito conforme dados físicoquímicos apresentados. Também não é descartado o alto índice de partículas sólidas, produtos de combustão de matas na região durante o período de estiagem. A absorção de substâncias particuladas pode influenciar nos níveis de formação de subprodutos de cloração, além do alto índice de CO2 presente na atmosfera. Nas demais estações de tratamento de água, há formação de trialometanos, mas nos níveis abaixo dos especificados pela Portaria 518/2004 do Ministério da Saúde. Não há relato de estudos realizados quanto aos níveis de trialometanos nas águas de abastecimento público no Estado de Rondônia. É importante um acompanhamento periódico quanto à formação dos produtos e um estudo mais aprofundado de adequação de tempo de exposição com cloro livre para minimizar ainda mais os níveis formados de trialometanos. Importante também um monitoramento nas águas dos rios que já possuem formação ou apresentam uma certa quantidade de trialometanos, que podem ser resíduos industriais. A saúde pública é uma prioridade e a água contendo trialometanos pode estar correlacionada com doenças carcinogênicas e mutagênicas. ________________________________________________________________________________________ ABSTRACT / In the water supplies of drinking water is the common use of chlorine and its derivatives. The powers of oxidation of free chlorine on reducing bacteria and protect the water against the proliferations of microorganisms. The mesoregion eastern state of Rondonia, made by municipalities Cacoal, Ji-Parana, Espigão d'Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d'Oeste, Ministro Andreazza and Presidente Medici that were part of the study of this dissertation, is characterized by the presence of rivers that serve as abstraction of water to be treated and supplied to the population. Due to various studies with respect to the presence of chemical contaminants formed after the chlorination of water, mainly the formation of trihalomethanes, these studies seeking to correlate the possibility of these compounds are carcinogenic and mutagenic, in this study were analyzed the levels of trihalomethanes formed at stations water treatment plants. The samples were collected in times seasonal and the results demonstrated the existence of hot spots on the formation of trihalomethanes, including some possible reasons are: Ji-Parana in the contamination of raw water containing trihalomethanes, especially dichloromethane, and also the provision of equipment, causing a greater contact of free chlorine with organic substances. In Alta Floresta d'Oeste in the precarious decanters and filters that is not compliant with the flow of treatment. According to this study in rainy seasons are decreased levels of trihalomethanes, different from those presented in studies in other locations. There is the possibility of soil characteristics in the region of study and influence to make dilution of the bed as physical-chemical data submitted. It is not discarded the high rate of solid particles, products of burning of forests in the region during the drought. The absorption of particulate substances can influence the levels of training for byproducts of chlorination, in addition to this high rate of CO2 in the atmosphere. In other water treatment plants, there is formation of trihalomethanes, but at levels below those specified by the Ordinance 518/2004 of the Ministério da Saúse. There is no report of studies about the levels of trihalomethanes in public water supply in the state of Rondônia. It is important periodic monitoring on the training of products and further study of adequacy of time of exposure with free chlorine to minimize further the levels of trihalomethanes formed. Important also a tracking in the waters of rivers that already have training or have a certain amount of trihalomethanes, which can be industrial waste. Public health is a priority and water containing trihalomethanes can be correlated with disease carcinogenic and mutagenic.
46

Reuso de água em piscicultura no Distrito Federal : potencial para pós-tratamento de águas residuárias associado à produção de pescado

Felizatto, Mauro Roberto January 2000 (has links)
Dissertação (mestrado)-Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2000. / Submitted by Guilherme Lourenço Machado (gui.admin@gmail.com) on 2011-06-09T11:47:14Z No. of bitstreams: 1 2000_MauroRobertoFelizatto.pdf: 1241636 bytes, checksum: 69e2662a676fe34bcd4c86c4c95a0c6b (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2011-06-09T12:38:45Z (GMT) No. of bitstreams: 1 2000_MauroRobertoFelizatto.pdf: 1241636 bytes, checksum: 69e2662a676fe34bcd4c86c4c95a0c6b (MD5) / Made available in DSpace on 2011-06-09T12:38:45Z (GMT). No. of bitstreams: 1 2000_MauroRobertoFelizatto.pdf: 1241636 bytes, checksum: 69e2662a676fe34bcd4c86c4c95a0c6b (MD5) / O presente trabalho procurou avaliar o potencial do reúso de água em piscicultura, como pós-tratamento de efluentes de lagoas de estabilização em série associado à produção de pescado. O procedimento experimental incluiu a construção de uma unidade piloto contando com dois tanques operando em paralelo, sendo um cultivado com peixes e outro para controle. Neste trabalho foi explorado o policultivo de tilápias do Nilo (Oreochromis niloticus) consorciadas com carpas prateadas (Hipophthalmychtis molitrix). O crescimento dos peixes foi avaliado pela biometria mensal de amostras, e ao final do experimento foi verificada a condição higiênico-sanitária (Coliformes fecais, Salmonelas e Staphylococcus aureus) dos exemplares cultivados durante os quatro meses do experimento. A taxa de sobrevivência dos peixes foi determinada através da contagem inicial e final de exemplares. A eficiência do processo como pós-tratamento de efluentes de lagoas de estabilização em série foi avaliada pelas determinações de pH, alcalinidade, DQO total e filtrada, DBO, NTK total e filtrado, nitrogênio amoniacal, nitrogênio nitrificado, fósforo total e filtrado, ortofosfato, clorofila-a, sólido suspensos totais (SST), coliformes fecais e totais, nas amostras de afluente e efluente de ambos tanques (piscícola e controle). Foi verificada a total mortandade das carpas prateadas já no primeiro mês do ensaio, ao passo que as tilápias do Nilo, embora também sofrendo perda de exemplares ao longo do experimento, apresentaram um índice de 13% de sobrevivência. A justificativa para tal fato foi o elevado teor de amônio presente na amostra bruta (valor mediano igual a 8,11 mg/l). Entretanto, foi observada uma taxa de crescimento relativa de 1,21% (diária) para as tilápias remanescentes, as quais, mediante análises microbiológicas foram consideradas aptas ao consumo humano. Quanto ao aspecto específico de tratamento de efluentes utilizando peixes, foram obtidas remoções de 15% para SST e 12% para Clorofila-a. Não foi observada qualquer remoção de matéria orgânica, nutrientes e coliformes. _______________________________________________________________________________ ABSTRACT / This work intended to evaluate the direct reuse of wastewater in aquaculture, both as a post-treatment process to stabilization ponds effluents and food production. The experimental procedure comprised the building of a pilot plant with two parallel operating tanks, one of them reared with fishes and the other one acting as a control unity. Two species were selected, Nile tilapias (Oreochromis niloticus) and silver carps (Hypophthalmychtis molitrix) and its growth was evaluated by biometry. The sanitary condition of the reared fishes, at the end of the four month experiment, was evaluated by measuring fecal coliforms, Salmonellas sp. and Staphylococcus aureus. The survival rate of fishes was also determined. The process efficiency, as a post-treatment unity, was assessed by measuring pH, alkalinity, COD, BOD, TKN, ammonium, nitrate, total phosphorus, orthophosphate, chlorophyll-a, total suspended solids (TSS), total and fecal coliforms, for raw and treated samples. the first month of the experiment it was obsrved that all silver carps died, due to high ammonium concentration in the raw samples (median value of 8,11 mg/l), while the Nile tilapias, though also suffering some losses during the whole experiment, had a 13% survival rate. The remaining tilapias had a 1.21% daily relative growth rate, and were considered suitable for human consumption. As a post-treatment unity, the tank reared with fishes obtained removal rates of 15% for TSS and 12% for chlorophyll-a, while no removals of organic matter, nutrients and total and fecal coliforms were observed.
47

Tecnologia alternativa em drenagem urbana: telhado verde

SILVA, Thomas Fernandes da 07 August 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-23T19:30:12Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-29T22:11:43Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Made available in DSpace on 2018-08-29T22:11:43Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) Previous issue date: 2017-08-07 / FACEPE / A urbanização de forma desordenada das cidades brasileiras proporciona a redução das áreas verdes e o aumento das áreas impermeáveis, favorecendo o aumento na velocidade do escoamento superficial, fazendo com que a água seja deslocada do ambiente o mais rápido possível, gerando áreas de inundação a jusante. As novas alternativas propostas para resolver problemas de drenagem urbana buscam, de uma forma eficiente, trata-los o mais próximo possível da fonte. Uma alternativa, natural e sustentável é a implantação dos telhados verdes, que se caracteriza pela aplicação de vegetação sobre a cobertura de edificações com impermeabilização e drenagem adequadas. Este trabalho tem a finalidade de investigar a funcionalidade de um telhado verde instalado no IPA no município de Caruaru, com relação a sua capacidade de retenção da vazão da água pluvial escoada, e avaliar o tratamento do efluente do telhado verde pelo sistema de filtração descendente em areia. Utilizou-se vegetação típica de regiões semiáridas, Babosa (Aloe Vera) e Coroa-de-Frade (Melocactus Zehntneri), e comparou-se ao telhado convencional. Após o uso de simulador de chuva, analisou-se a capacidade de retenção do telhado através do balanço hídrico no sistema. Foram realizados ensaios de bancada para avaliar a eficiência de duas configurações de filtro de areia, com diferentes granulometrias, em relação ao melhoramento da qualidade do efluente dos telhados verdes e do efluente sintético, desenvolvido em laboratório. Os telhados verdes apresentaram boa capacidade de retenção, chegando a valores de 75% e 86%, para os telhados verdes Babosa e Coroa-de-Frade, respectivamente. Observou-se um retardo na ocorrência do pico de vazão de até 14 minutos no telhado verde Babosa em relação ao telhado Convencional (telha cerâmica) e um retardo de até 21 minutos no telhado verde Coroa-de-Frade em relação ao telhado Convencional (telha cerâmica). Sendo a vegetação Coroa-de-Frade uma boa possibilidade de uso para este fim em regiões semiáridas. O desempenho do filtro foi analisado, através dos parâmetros de qualidade da água para irrigação, condutividade elétrica, sólidos dissolvidos totais, cálcio, magnésio, sódio, carbonatos, bicarbonatos, cloretos, sulfatos, nitrogênio–nitrato, nitrogênio amoniacal, fósforo–fosfato, potássio, boro, acidez ou alcalinidade e razão de adsorção de sódio. Conforme as análises observou-se que o filtro de areia apresentou-se como uma alternativa para o tratamento do efluente gerado pelo telhado verde em estudo. / The urbanization in a disorderly way of the Brazilian cities causes the reduction of green areas and the increase of impermeable areas, favoring the increase in the speed of the surface runoff, causing the water to be displaced from the environment as quickly as possible, generating flood areas downstream. The new alternatives proposed to solve problems of urban drainage seek, in an efficient way, treat them as close as possible to the source. An alternative, natural and sustainable is the implementation of green roofs, which is characterized by the application of vegetation on the roof of buildings with adequate waterproofing and drainage. This work has the purpose of investigating the functionality of a green roof installed in the IPA in the city of Caruaru, in relation to its capacity of retention of the flow of the drained pluvial water, and to evaluate the treatment of the effluent of the green roof by the system of descending filtration in sand. Typical vegetation of semi-arid regions, Babosa (Aloe Vera) and Coroa-de-Frade (Melocactus Zehntneri) was used, and compared to the conventional roof. After the use of rainfall simulator, the retention capacity of the roof was analyzed through the water balance in the system. Bench tests were carried out to evaluate the efficiency of two sand filter configurations, with different particle sizes, in relation to the improvement of the quality of green roofs and synthetic effluent, developed in the laboratory. The green roofs showed good retention capacity, reaching values of 75% and 86%, for the green roofs of Babosa and Coroa de Frade, respectively. There was a delay in the occurrence of the peak flow of up to 14 minutes on the roof of the Babosa green roof compared to the conventional roof (ceramic tile) and a delay of up to 21 minutes on the roof green Crown of Frade in relation to the conventional Roof Ceramics). Since the Coroa-de-Frade vegetation is a good possibility of use for this purpose in semi-arid regions. The performance of the filter was analyzed through water quality parameters for irrigation, Electric Conductivity, Total Dissolved Solids, Calcium, Magnesium, Sodium, Carbonates, Bicarbonates, Chlorides, Sulphates, Nitrogen-Nitrate, Ammoniacal Nitrogen, Phosphorus-Phosphate, Potassium, Boron, Acidity or Alkalinity and Sodium Adsorption Ratio. According to the analyzes, it was observed that the sand filter was may be considered as an alternative for the treatment of the effluent generated by the green roof under study.
48

Desinfecção de agua para abastecimento com radiação ultravioleta : eficiencia bactericida e uma analise economica e energetica

Pires, Marco Roberto 14 May 1997 (has links)
Orientador: Roberto Feijo de Figueiredo, Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T18:40:13Z (GMT). No. of bitstreams: 1 Pires_MarcoRoberto_M.pdf: 4765440 bytes, checksum: 68b559c8fd33a90d801120162c2d3e21 (MD5) Previous issue date: 1997 / Resumo: A desinfecção de água com radiação ultravioleta tem demonstrado ser uma alternativa à cloração. Os objetivos deste trabalho são: estudo da inativação dos microrganismos; análise' econômica do sistema de uv comparativamente a um sistema equivalente de desinfecção com cloro; e comparação do consumo de energia elétrica entre estes sistemas. Utilizou-se um reator (câmara de desinfecção), equipado com lâmpada de uv, operando no sistema de batelada. Os Microrganismos inativados foram E.coli, P.aeruginosa, A.hydrophila, E.faecalis e V.cholera. A análise econômica foi realizada em termos de implantação, operação e manutenção dos sistemas de cloro e uv com base nos preço de mercado. A comparação energética foi baseada na relação de volume de água desinfetada pelo consumo de energia elétrica entre os sistemas. A E.coli se mostrou o microrganismo de maior resistência inicial, mas a maior constante de inativação; o E.faecalis foi o mais resistente. O sistema de uv fornece água desinfetada a um custo de R$ 0,037 por habitante por ano. O consumo de energia elétrica entre os sistemas é equivalente para baixa dose de cloro. A radiação uv para desinfecção de água demonstra ser eficiente bactericida e compete economicamente com o cloro / Abstract: Ultraviolet radiation has been accepted as an altemative to chlorination for disinfection of water. The main subjects in this work can be summarized as follows: microorganism inactivation survey; comparative economical analysis between uv system and chlorine disinfection;comparative electrical energy consumption between them. A batch reactor, equipped with uv lamp, was used in the tests. E. coli, P.aeruginosa, A.hydrophila, E.faecalis, V.cholera, were the microorganisms employed for the study of inactivation. The economical analysis was accomplished based on capital costs, operation and maintenance of uv and chlorine system based on current market prices of components. The energetic analysis comparison was based on the volume ratio between disinfected water and electrical energy consumption of both the systems. The E.coli was the bacteria with the strongest initial resistance but the greatest inactivation constant. E.faecalis was the most resistant. The uv system provide disinfected water by R$ 0,037 per person per year. For low chlorine doses the electrical energy consumption between the two systems are equivalent. Finally, the work shows that uv radiation used for water disinfection is an important tool as an efficient bactericidal and that it competes economically with chlorination / Mestrado / Mestre em Planejamento de Sistemas Energéticos
49

Ocorrencia de oocistos de Cryptosporidium spp. e cistos de Giardia spp. em diferentes pontos do processo de tratamento de agua, em Campinas, São Paulo, Brasil

Cantusio Neto, Romeu 03 August 2018 (has links)
Orientador: Regina Maura Bueno Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-03T20:53:37Z (GMT). No. of bitstreams: 1 CantusioNeto_Romeu_M.pdf: 1625548 bytes, checksum: e91f470bbd9fce0e7bb535b92359fbac (MD5) Previous issue date: 2004 / Mestrado
50

Avaliação do emprego de areia de britagem como leito filtrante de filtros rápidos para tratamento de água / Evaluation of the use of crushed rock sand as filter bed for rapid filters applied for drinking water treatment

Silva, Bruno Moreno Ramos 20 February 2018 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2018-06-14T17:22:23Z No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) / Made available in DSpace on 2018-06-14T17:22:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) Previous issue date: 2018-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste trabalho foi avaliar o emprego de areia de britagem como leito filtrante de filtros rápidos descendentes no tratamento de água para consumo humano. Testes preliminares em unidade de filtração de bancada (proveta de 2 L) indicaram: (i) que o leito de areia de britagem não afeta negativamente a qualidade da água filtrada (turbidez, pH e condutividade elétrica); (ii) elevado potencial de remoção de turbidez de água decantada; (iii) eficiência da retrolavagem para limpeza do leito filtrante. Na sequência, foram realizados ensaios em duas unidades piloto de filtração rápida (construídas em tubulação de acrílico com 19 cm de diâmetro interno e comprimento total de 267 cm): um com areia de britagem e outro, como unidade de controle, com areia natural de rio. Ambos os leitos filtrantes foram preparados com granulometria e profundidade de acordo com as especificações da norma da ABNT para filtração rápida com areia natural. As duas areias foram ainda caracterizadas em termos de: composição química, massa específica, densidade aparente, porosidade, solubilidade em ácido, potencial zeta dos grãos e coeficiente de esfericidade. Ao longo de quatro meses foram monitoradas 14 carreiras de filtração, as quais foram caracterizadas, para taxas de filtração de 180, 270 e 360 m3 m'2 d'1, em termos de: (i) duração das carreiras; (ii) perda de carga ao longo do leito filtrante; (iii) remoção de turbidez ao longo do leito filtrante; (iv) índices de filtrabilidade - Índice de Ives e Índice de Hudson. Em geral, o desempenho do filtro de areia de britagem foi similar ou superior ao filtro de areia natural, produzindo água filtrada com turbidez inferior a 0,50 uT ao longo de toda a carreira, com duração e desenvolvimento da perda de carga próximos aos do filtro de areia natural. Conclui- se que a areia de britagem apresenta elevado potencial de emprego como leito filtrante de filtros rápidos para o tratamento de água para consumo humano, sem desvantagens técnicas-operacionais e com atrativos ambientais / The objective of this work was to evaluate the use of crushed rock sand as a filter bed in rapid down flow filtration for drinking water treatment. Preliminary tests using a bench-scale filtration unit (2 L measuring cylinder) indicated: (i) that the crushed rock sand bed does not negatively affect the quality of the filtered water (turbidity, pH and electrical conductivity); (ii) a high potential for turbidity removal; (iii) backwashing is efficient in cleaning the filter bed. Then, trials were carried out using two pilot-scale rapid filtration units (acrylic tubes, internal diameter of 19 cm and total length of 267 cm): one with a crushed rock sand filter bed and the other (a control unit), with natural river sand. Both filter media were prepared in accordance with the Brazilian standards for rapid down flow sand filtration (particle size range and filter bed depth), and were further characterized in terms of: chemical composition, particles density, bulk density, porosity, acid solubility, zeta potential and sphericity coefficient. Over four months, 14 filter runs using filtration rates of 180, 270 and 360 m3.m'2.d'1 were monitored and characterized in terms of (i): filter run length; (ii) head loss increase along the filter bed depth; (iii) turbidity removal along the filter bed depth; (iv) filterability indexes - Ives Index and Hudson Index. Overall, the performance of the crushed rock sand filter was similar to or even better than that of the natural river sand filter, producing filtered water with turbidity lower than 0.50 NTU along the entire filter run, with duration and head loss increasing rates similar to those of the natural sand filter. It is concluded that crushed rock sand presents a high potential for use as a filter media for rapid filtration in drinking water treatment, with environmental advantages and no technical or operational disadvantages.

Page generated in 0.0437 seconds