• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 23
  • 23
  • 23
  • 13
  • 9
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de processos de caracterização e remediação de passivos ambientais de contaminação por hidrocarbonetos /

Silva, Palloma Ribeiro da. January 2009 (has links)
Orientador: José Augusto de Lollo / Banca: Maurício Augusto Leite / Banca: Lissandra Xavier Ito / Resumo: A remediação de solos e águas subterrâneas impactadas por derramamentos de petróleo é uma atividade que geralmente envolve altos custos e longos períodos de tempo. Técnicas convencionais como a escavação dos solos contaminados, seguida de tratamento ou disposição em aterros, têm sido utilizadas para efetuar a remediação de locais contaminados, apesar de apresentarem, muitas vezes, elevados custos, bem como possibilitarem impactos adicionais ao ambiente. Além destas, outras técnicas têm sido aprimoradas, testadas e avaliadas em relação a sua eficiência/eficácia e custo, incluindo a contenção, biorremediação, desorção térmica, oxidação química, extração de vapores, bombeamento e tratamento de águas subterrâneas. Uma técnica de bombeamento e tratamento do solo e água subterrânea é o MPE - Extração Multifásica. O presente estudo caracterizou duas ocorrências de passivos ambientais e o processo de remediação da fase livre das águas subterrâneas contaminadas por hidrocarbonetos derivados do petróleo utilizando o sistema de extração multifásica. No estudo de caso foram analisados dois postos. No posto 1 foi calculada uma área de 2.000m² de fase livre, resultando em um volume de 300m3. O posto 2 apresentou um volume menor de fase livre, foi calculada uma área de 40m², com volume de 1m3. Após 12 meses de operação do sistema MPE houve uma redução de 100% da espessura da fase livre no posto 1 . O posto 2, que possui solo mais argiloso, em 16 meses de operação houve uma redução de 99% da espessura da fase livre. Como esperado, a remoção da fase livre pelo sistema MPE foi mais eficiente no solo argiloarenoso, encontrado no posto1, mas contrariando a muitos autores também apresentou eficiência no solo argiloso do posto 2 / Abstract: Remediation of soil and groundwater impacted by oil spill is a process which normally involves elevated costs and long periods of time. Conventional techniques such as excavation of contaminated soils followed by special treatments or deposit on landfills has been used to remediate areas with contaminated soil. However this treatment can also create new impacts to the environment where contamination had been deposited. In addition, new techniques such as contention, bioremediation, thermal desorption, chemical oxidation, air stripping and pumping treatment has been developed, tested and evaluated by their efficiency, effectiveness and costs. The Multi Phase Extraction (MPE) is a pumping treatment technique used in the present study. The study characterised two episodes of environmental liabilities, as well as the process of remediation, applying the MPE technique to remediate the free phase of petroleum hydrocarbons present in the groundwater. The first area studied was a petrol station which had an area of 2000 square meters of petroleum hydrocarbon contaminated soil, resulting in a volume of 300 cubic meters of free phase in the groundwater. The second petrol station had a volume of free phase of petroleum hydrocarbon smaller than the first one. It had an area of 40 square meters of contaminated soil, resulting a volume of 1 cubic meter of free phase in the ground water. Twelve months after the MPE system was implanted, the thickness of the free phase had decreased 100%, at the first petrol station. The second area, where the MPE was implanted, took sixteen months to reduce 99% of the petroleum hydrocarbon thickness, owing to the second petrol station being situated in an area of clay soil. The remediation of the petroleum hydrocarbon in the groundwater by the MPE system was more efficient in the first area as expected, owing to the knowledge that the first petrol station is located in... (Complete abstract click electronic access below) / Mestre
2

Avaliação de processos de caracterização e remediação de passivos ambientais de contaminação por hidrocarbonetos

Silva, Palloma Ribeiro da [UNESP] 21 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-21Bitstream added on 2014-06-13T18:52:42Z : No. of bitstreams: 1 silva_pr_me_ilha.pdf: 5300308 bytes, checksum: ee87f9ce167be289acae69b3bea0a9d3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A remediação de solos e águas subterrâneas impactadas por derramamentos de petróleo é uma atividade que geralmente envolve altos custos e longos períodos de tempo. Técnicas convencionais como a escavação dos solos contaminados, seguida de tratamento ou disposição em aterros, têm sido utilizadas para efetuar a remediação de locais contaminados, apesar de apresentarem, muitas vezes, elevados custos, bem como possibilitarem impactos adicionais ao ambiente. Além destas, outras técnicas têm sido aprimoradas, testadas e avaliadas em relação a sua eficiência/eficácia e custo, incluindo a contenção, biorremediação, desorção térmica, oxidação química, extração de vapores, bombeamento e tratamento de águas subterrâneas. Uma técnica de bombeamento e tratamento do solo e água subterrânea é o MPE - Extração Multifásica. O presente estudo caracterizou duas ocorrências de passivos ambientais e o processo de remediação da fase livre das águas subterrâneas contaminadas por hidrocarbonetos derivados do petróleo utilizando o sistema de extração multifásica. No estudo de caso foram analisados dois postos. No posto 1 foi calculada uma área de 2.000m² de fase livre, resultando em um volume de 300m3. O posto 2 apresentou um volume menor de fase livre, foi calculada uma área de 40m², com volume de 1m3. Após 12 meses de operação do sistema MPE houve uma redução de 100% da espessura da fase livre no posto 1 . O posto 2, que possui solo mais argiloso, em 16 meses de operação houve uma redução de 99% da espessura da fase livre. Como esperado, a remoção da fase livre pelo sistema MPE foi mais eficiente no solo argiloarenoso, encontrado no posto1, mas contrariando a muitos autores também apresentou eficiência no solo argiloso do posto 2 / Remediation of soil and groundwater impacted by oil spill is a process which normally involves elevated costs and long periods of time. Conventional techniques such as excavation of contaminated soils followed by special treatments or deposit on landfills has been used to remediate areas with contaminated soil. However this treatment can also create new impacts to the environment where contamination had been deposited. In addition, new techniques such as contention, bioremediation, thermal desorption, chemical oxidation, air stripping and pumping treatment has been developed, tested and evaluated by their efficiency, effectiveness and costs. The Multi Phase Extraction (MPE) is a pumping treatment technique used in the present study. The study characterised two episodes of environmental liabilities, as well as the process of remediation, applying the MPE technique to remediate the free phase of petroleum hydrocarbons present in the groundwater. The first area studied was a petrol station which had an area of 2000 square meters of petroleum hydrocarbon contaminated soil, resulting in a volume of 300 cubic meters of free phase in the groundwater. The second petrol station had a volume of free phase of petroleum hydrocarbon smaller than the first one. It had an area of 40 square meters of contaminated soil, resulting a volume of 1 cubic meter of free phase in the ground water. Twelve months after the MPE system was implanted, the thickness of the free phase had decreased 100%, at the first petrol station. The second area, where the MPE was implanted, took sixteen months to reduce 99% of the petroleum hydrocarbon thickness, owing to the second petrol station being situated in an area of clay soil. The remediation of the petroleum hydrocarbon in the groundwater by the MPE system was more efficient in the first area as expected, owing to the knowledge that the first petrol station is located in... (Complete abstract click electronic access below)
3

Validação de metodologia para determinação de cadaverina e putrecina por LC-MS/MS e aplicação em água como indicador de contaminação por necrochorume /

Conrado, Marli, 1972-, Silva, Marcos Rivail da, 1956-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Química. January 2015 (has links) (PDF)
Orientador: Marcos Rivail da Silva. / Co-orientador: Martinho Rau. / Dissertação (Mestrado em Química) - Programa de Pós-Graduação em Química, Centro de Ciências Exatas e Naturais, Universidade Regional de Blumenau, Blumenau.
4

Risco e impactos de poluição nas águas subterrâneas pelo uso e ocupação do solo no Porto das Dunas - Aquiraz/CE / Risk and impact of pollution in groundwater by use and occupation of the soil in Porto das Dunas - Aquiraz/CE

Araújo, Karen Vendramini de January 2014 (has links)
ARAÚJO, K. V. Risco e impactos de poluição nas águas subterrâneas pelo uso e ocupação do solo no Porto das Dunas - Aquiraz/CE. 2014. 105 f. Dissertação (Mestrado em Geologia) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2015-01-15T17:06:36Z No. of bitstreams: 1 2014_dis_kvaraujo.pdf: 19618260 bytes, checksum: 8286027abf51b89e937eb1098ed9d728 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-03-22T13:03:13Z (GMT) No. of bitstreams: 1 2014_dis_kvaraujo.pdf: 19618260 bytes, checksum: 8286027abf51b89e937eb1098ed9d728 (MD5) / Made available in DSpace on 2016-03-22T13:03:13Z (GMT). No. of bitstreams: 1 2014_dis_kvaraujo.pdf: 19618260 bytes, checksum: 8286027abf51b89e937eb1098ed9d728 (MD5) Previous issue date: 2014 / This work was performed at Porto das Dunas, in the city of Aquiraz, aiming to assess the risk and impacts of pollution in groundwater, resulting from the use and occupation of area. The methodology consisted of a literature search, preparation of records of wells and thematic bases, updating the register of pre-existing wells, obtaining data for pH, total dissolved solids (TDS) and electrical conductivity (EC) in 32 wells, collecting 15 samples for physicochemical and bacteriological analysis and processing and data integration. Porto das Dunas has an intense tourism, being densely occupied by homes, hotels, resorts and tourist developments. However, the area does not have a water supply and sewerage system, being fully supplied by groundwater and the disposal of sewage accomplished through septic cesspools. The Dunes Aquifer is the most important in the area of research both in occurrence (90%) and in water potential. Based on the methodology GOD, the Dunes Aquifer in the area of research, has medium to high vulnerability. The vulnerability of the Dunes Aquifer associated with a constant contaminant load from septic cesspools existing in the area is a high risk of groundwater pollution from Porto das Dunas. The impacts of the use and occupation were assessed using qualitative study of groundwater in the area of research performed based on the parameters of pH, total dissolved solids (TDS) and electrical conductivity (EC) from the field and physicochemical and bacteriological analyzes. It was found that concentrations of pH, TDS and EC are within recommended by Ordinance nº 2914/2011 MS standards. Have the 15 physicochemical analyzes showed concentrations of hardness, turbidity, fluoride, sodium nitrite within the potability standards and concentrations of chloride (1 sample), iron (2 samples) and nitrate (1 sample) out of potability standards. In the microbiological quality of water, it was found that 94% of the samples showed total or fecal coliforms. The presence of coliforms indicates contamination in groundwater arising from existing domestic cesspools in the area. / Este trabalho foi realizado no Porto das Dunas, no município de Aquiraz, Ceará, com o objetivo de avaliar o risco e os impactos de poluição nas águas subterrâneas, decorrentes do uso e ocupação do solo. A metodologia de trabalho constou de pesquisa bibliográfica, elaboração do cadastro de poços e bases temáticas, atualização do cadastro de poços pré-existente, obtenção de dados de pH, sólidos totais dissolvidos (STD) e condutividade elétrica (CE) em 32 poços, coleta de 15 amostras para análises físico-químicas e bacteriológicas e tratamento e integração dos dados. O Porto das Dunas possui um turismo intenso, sendo densamente ocupado por casas de veraneio, hotéis, resorts e empreendimentos turísticos. Porém, a área não dispõe de rede de abastecimento de água e nem rede de esgoto, sendo totalmente abastecida por água subterrânea e o despejo de esgoto realizado através de fossas sépticas ou negras. O Aquífero Dunas é o mais importante na área de pesquisa tanto em ocorrência (90%) quanto em potencial hídrico. Com base na metodologia GOD, o Aquífero Dunas, na área de pesquisa, possui vulnerabilidade média a alta. A vulnerabilidade do Aquífero Dunas associada a uma carga contaminante constante proveniente das fossas sépticas existentes na área representa um alto risco de poluição das águas subterrâneas do Porto das Dunas. Os impactos decorrentes do uso e ocupação do solo foram avaliados através do estudo qualitativo das águas subterrâneas da área de pesquisa realizado com base nos parâmetros de pH, sólidos totais dissolvidos (STD) e condutividade elétrica (CE) obtidos em campo e análises físico-químicas e bacteriológicas. Verificou-se que as concentrações de pH, STD e CE encontram-se dentro dos padrões recomendados pela Portaria nº 2914/2011 do MS. Já as 15 análises físico-químicas realizadas apresentaram concentrações de dureza, turbidez, fluoretos, sódio e nitrito dentro dos padrões de potabilidade e concentrações de cloretos (1 amostra), ferro (2 amostras) e nitrato (1 amostra) fora dos padrões de potabilidade. Em relação à qualidade microbiológica das águas, verificou-se que 94% das amostras analisadas apresentaram coliformes totais ou fecais. A presença de coliformes nas águas subterrâneas indica contaminação oriunda das fossas domésticas existentes na área.
5

Avaliação do perigo à poluição das águas subterrâneas no município de Piracicaba SP /

Garcia, Claudinei. January 2018 (has links)
Orientador: Fabiano Tomazini da Conceição / Coorientadora: Anna Silvia Palcheco Peixoto / Banca: Rodrigo Braga Moruzzi / Banca: Luiz Roberto Moretti / Resumo: Este trabalho buscou a avaliação do perigo à poluição das águas subterrâneas no município de Piracicaba, através da interação entre os índices de vulnerabilidade intrínseca e vulnerabilidade específica dos aquíferos aflorantes no município de Piracicaba, motivado pela importância estratégica destas fontes, pela ausência de estudos específicos locais e pela crescente demanda de exploração de cunho econômico da área de estudo. Para a análise dos índices de vulnerabilidade intrínseca, que define-se como a capacidade de atenuação natural do meio local à contaminação de determinado aquífero imposta por uma carga contaminante, utilizou-se do método GOD - groundwater hydraulic confinement; overlaying strata; depth to groundwater table (FOSTER, 1987; FOSTER; HIRATA, 1988), e para a avaliação da vulnerabilidade específica que considera a probabilidade de determinado sistema aquífero ser exposto a um contaminante, classe de contaminantes ou atividade contaminante, utilizou-se do método POSH - pollutant origin, surcharge hydraulically (FOSTER, et al., 2006) e da análise do potencial de contaminação das áreas urbanas e rurais por fontes de nitrato. A manipulação de dados envolveu informações de poços profundos outorgados, pedologia e litologia da área de estudo, informações de uso do solo e de fontes potenciais de contaminação local, obtidos de fontes públicas e privadas. A avaliação do perigo à poluição das águas subterrâneas, que pode ser definido como a interação entre a vulnerabilida... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work sought to evaluate the danger to groundwater pollution in the municipality of Piracicaba through the interaction between intrinsic vulnerability indexes and specific vulnerability of outlying aquifers in the city of Piracicaba, motivated by the strategic importance of these sources due to the absence of specific local studies and by the growing demand for economic exploration of the study area. For the analysis of the intrinsic vulnerability indexes, which is defined as the natural attenuation capacity of the local environment to the contamination of a given aquifer imposed by a contaminant load, the GOD method was used - groundwater hydraulic confinement; overlaying strata; depth to groundwater table (FOSTER, HIRATA, 1988), and for the assessment of the specific vulnerability that considers the probability of a certain aquifer system being exposed to a contaminant, class of contaminants or contaminant activity, the POSH method - pollutant origin, surcharge hydraulically (FOSTER, et al., 2006) and the analysis of the potential of contamination of urban and rural areas by nitrate sources. Data manipulation involved information from deep wells, pedology and lithology of the study area, land use information and potential sources of local contamination obtained from public and private sources. The groundwater hazard assessment, which can be defined as the interaction between intrinsic vulnerability and specific vulnerability, was the interaction of the results obtained ... (Complete abstract click electronic access below) / Mestre
6

Estudo da qualidade de águas de poços no Iguape-CE / Study of quality of water wells in Iguape-CE

Rodrigues Neto, Miguel Paulo 05 June 2014 (has links)
RODRIGUES NETO, M. P. Estudo da qualidade de águas de poços no Iguape-CE. 2014. 63 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-04-10T19:02:48Z No. of bitstreams: 1 2014_dis_mprodriguesneto.pdf: 1557286 bytes, checksum: f244389a0f790e42e515f5cdf85cafd6 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-04-16T17:20:12Z (GMT) No. of bitstreams: 1 2014_dis_mprodriguesneto.pdf: 1557286 bytes, checksum: f244389a0f790e42e515f5cdf85cafd6 (MD5) / Made available in DSpace on 2015-04-16T17:20:12Z (GMT). No. of bitstreams: 1 2014_dis_mprodriguesneto.pdf: 1557286 bytes, checksum: f244389a0f790e42e515f5cdf85cafd6 (MD5) Previous issue date: 2014-06-05 / According to the United Nations (UN), the target of one of the objectives Development Goals of halving the number of people without access to water drinking was reached - however, 768 million people still do not enjoy this advance overall, especially in rural areas. In this context, the population of Iguape, a district of municipality of Aquiraz-EC, is part of this minority, lacking sewage and supply for water distribution network. Thus, a study was performed to During the year 2013 with the objective of determining if the water wells used by population - the main source of those goods - was in accordance with the parameters of potability provided for in the regulations. The results show that for the plurality of wells human consumption have parameters outside the limits accepted by the existing laws - presence of E. coli, for example. As a reference for this study the Quality Index Canadian Council of Ministers of the Environment was employed to facilitate the Understanding of the data set and revealed that the ten wells monitored only one presents water quality rated as Good / Segundo a Organização das Nações Unidas (ONU), a meta de um dos Objetivos de Desenvolvimento do Milênio de reduzir pela metade o número de pessoas sem acesso a água potável foi atingido – entretanto, 768 milhões de pessoas ainda não usufruem desse avanço global, especialmente nas áreas rurais. Nesse contexto, a população do Iguape, um distrito do município de Aquiraz-CE, faz parte dessa minoria, carecendo de coleta de esgoto e de abastecimento por rede de distribuição de água. Dessa forma, foi realizado um estudo ao longo do ano de 2013 com o objetivo de verificar se a água dos poços utilizados pela população – principal fonte desse bem – estava de acordo com os parâmetros de potabilidade previstos nas legislações vigentes. Os resultados mostram que diversos poços destinados ao consumo humano têm parâmetros fora dos limites aceitos pelas legislações vigentes – presença de E. Coli, por exemplo. Como referência para esse estudo o Índice de Qualidade do Conselho Canadense de Ministros do Meio Ambiente foi empregado para facilitar a compreensão do conjunto de dados e revelou que dos dez poços monitorados apenas um apresenta água com qualidade classificada como Boa
7

Remediação de águas subterrâneas contaminadas por compostos organoclorados (PCE/TCE) através do uso de carvão ativado e permanganato de potássio

Ávila, Luciano 02 March 2018 (has links)
Orientador : Prof. Dr. Jorg Metzger / Coorientadores: Prof. Dr. Marielle Feilstrecker e Profª Drª Patrícia Charvet / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 30/10/2012 / Inclui referências : f. 80-84 / Resumo: Este trabalho aborda os estudos realizados para remediação de águas subterrânea contaminada principalmente por tetracloroeteno (PCE) e tricloroeteno (TCE) no terreno de uma antiga indústria química. O desenvolvimento foi em três etapas distintas: remediação através da adsorção em carvão ativado; escala laboratorial para avaliação da degradabilidade dos compostos PCE/TCE com permanganato de potássio; e por fim aplicação de permanganato diretamente no freático na área da empresa. A remediação no terreno consistiu através de bombeamento da água subterrânea de nove poços, passando por uma coluna de carvão ativado. Na escala laboratorial foram realizados experimentos com amostras sintéticas e originais do poço de monitoramento de maior contaminação. A contaminação inicial diagnosticada era de 89.234 ?g/L de PCE e 65.567 de TCE. O emprego do permanganato ocorreu durante 10 campanhas de aplicação diretamente nos poços mais contaminados, em concentrações de 1, 4 e 10%. A adsorção em carvão ativado granular foi muito eficiente nos primeiros dez meses de operação obtendo uma remoção de 95% de PCE e 90% de TCE. O uso de permanganato em escala laboratorial foi muito eficiente para TCE e de difícil contato com o PCE. A aplicação em campo do permanganato, comprovou a necessidade de injeção sob pressão, a fim de aumentar o raio de influência do oxidante em solos argilosos. Os resultados obtidos comprovaram o êxito do tratamento de águas subterrâneas contaminadas com PCE/TCE mediante processos de oxidação com permanganato (in situ) e adsorção em carvão ativado granular (on site). Palavras-chave: PCE; TCE, remediação, carvão ativado e oxidação in-situ com permanganato. / Abstract: The present study was on the remediation of groundwater contaminated mainly by tetrachloroethene (PCE) and trichloroethene (TCE), in an area of an old chemical industry. The development was in three distinct steps: remediation through activated carbon, laboratory studies to evaluate the degradability of PCE/TCE with potassium permanganate and use of potassium permanganate directly on groundwater in the industry's area. The on-site remediation involved the pumping of groundwater from nine wells through an activated carbon column. Laboratory scale experiments were carried out with synthetic and original samples taken from the most contaminated monitoring well. The initial contamination diagnosed was of 89.234 ?g/L for PCE and of 65.567 ?g/L for TCE. The potassium permanganate was applied directly in the most contaminated wells in ten campaigns and in concentrations that varied from 1,4 to 10%. The granulated activated carbon adsorption was very efficient in the first months of operation and reached a removal of 95% of PCE and of 90% of TCE. The use of potassium permanganate was efficient for TCE removal but non effective for PCE. During the on-site applications it was concluded the need for pressurized injection and that there is a limit on the influence radius of the oxidant in clay soils. The results obtained were successful on the treatment of groundwater contaminated by PCE and TCE through granulated activated carbon and potassium permanganate oxidation. Keywords: PCE; TCE, remediation, activated charcoal, permanganate in-situ oxidation.
8

Avaliação da mobilidade de íons e metais da vinhaça através de ensaios de colunas em solo da Formação Rio Claro /

Ferreira, Thelma Maria. January 2018 (has links)
Orientador: Hung Kiang Chang / Banca: Miguel Angel Alfaro Soto / Banca: Sílvia Maria Ferreira Salvador / Resumo: No processo industrial da produção sucroalcooleira um dos efluentes gerados é a vinhaça, que se destaca pelo grande volume com que é produzida e pelo alto potencial fertilizante, característica que possibilita seu aproveitamento em atividades agrícolas, no entanto, a vinhaça também possui alto poder poluente. Neste contexto, o uso da vinhaça na fertilização de cana-de-açúcar, embora seja uma prática aceita, deve ser realizado de forma controlada, sendo regulamentado no Estado de São Paulo pela Companhia Ambiental do Estado de São Paulo - CETESB através da Norma Técnica P4.231. Devido a composição da vinhaça ser muito variável não há como estabelecer doses fixas, assim, atualmente as dosagens de aplicação no solo são calculadas em função das necessidades da planta em relação ao potássio, sendo consideradas a capacidade de troca catiônica do solo e as concentrações de potássio no solo e na vinhaça. Todavia, além da oscilação composicional da vinhaça, seus efeitos sobre cada tipo de solo também são muito diversos, podendo modificar parâmetros hidráulicos do solo e, consequentemente, alterar a velocidade de percolação da água e dos contaminantes presentes na solução. Diante desta problemática, para avaliar o uso da dosagem calculada pela Norma P4.231 da CETESB, foram realizados ensaios laboratoriais de percolação a carga constante, em colunas com amostras de solo arenoso da Formação Rio Claro previamente infiltradas com as doses de 0 (testemunho), 55 (equivalente a dose máxima pe... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the industrial production process of sugar and a lcohol, one of the effluents generated is vinasse, which stands out for the larg e volume produced and for the high fertilizing potential, allowing its use in agr icultural activities, however, the vinasse also has high pollution power. In this context, the use of vinasse in the fertilization of sugarcane, although it is an accepted practice, mus t be carried out in a controlled manner, being regulated in the State of São Paulo b y the Companhia Ambiental do Estado de São Paulo (CETESB) through Technical Stan dard P4. 231. Due to the composition of the vinasse being very variable, it is not possible to establish fixed doses, so, currently the dosages of application in the soil are calculated according to the needs of the plant in relation to potassium ion, considering the cation exchange capacity of the soil and the concentrations of pota ssium in soil and vinasse. In addition to the compositional oscillation of vinasse, its effects on each type of soil is also very diverse, being able to modify hydraulic p arameters of the soil and, consequently, to change the rate of percolation of the water and the contaminants present in the solution. In order to evaluate the u se of the dosage calculated by CETESB Standard P4.231, constant load percolation t ests were carried out in columns with samples of a sandy soil from the Rio C laro Formation previously infiltrated with the doses of 0 (control), 55 (equi valent to the maximum dos... (Complete abstract click electronic access below) / Mestre
9

O crescimento urbano e o risco à poluição das águas subterrâneas freáticas no entorno da lagoa da Parangaba, Fortaleza-Ceará

Oliveira, Magno Régis Barros de January 2013 (has links)
OLIVEIRA, Magno Régis Barros de. O crescimento urbano e o risco à poluição das águas subterrâneas freáticas no entorno da lagoa da Parangaba, Fortaleza-Ceará. 2013. 150 f. Dissertação (Mestrado em geologia)-Universidade Federal do Ceará, Fortaleza-CE, 2013. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-03T20:17:38Z No. of bitstreams: 1 2013_dis_mrboliveira.pdf: 15808452 bytes, checksum: f1104e7ae030bdd64677987d3fc76356 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-21T19:22:13Z (GMT) No. of bitstreams: 1 2013_dis_mrboliveira.pdf: 15808452 bytes, checksum: f1104e7ae030bdd64677987d3fc76356 (MD5) / Made available in DSpace on 2016-07-21T19:22:13Z (GMT). No. of bitstreams: 1 2013_dis_mrboliveira.pdf: 15808452 bytes, checksum: f1104e7ae030bdd64677987d3fc76356 (MD5) Previous issue date: 2013 / Este trabalho reúne informações referentes a um estudo geoambiental, no qual se utilizam dados geológicos e hidrogeológicos, além de ferramentas de Sistema de Informações Geográficas para qualificar o risco à poluição das águas subterrâneas freáticas no entorno da Lagoa da Parangaba no município de Fortaleza, Ceará. Os dados geológicos foram obtidos através de perfis de poços cedidos pelo Sistema de Informações de Águas Subterrâneas (SIAGAS), que foram essenciais para determinar os Sistemas Hidrogeológicos da área pesquisada. Foram utilizados fotos aéreas em diferentes épocas para avaliar o grau de modificação da paisagem da lagoa e a evolução urbana na região, avaliando os problemas ambientais provocados pelo crescimento urbano. Para qualificar a água subterrânea no entorno da lagoa, foram selecionados 20 poços para coletas de amostras de água, sendo avaliados parâmetros físico-químicos em 19 amostras no período de estiagem e 20 amostras no período chuvoso, além de 5 amostras referentes a qualidade microbiológica; nesse trabalho foram avaliadas as águas da Lagoa da Parangaba em três pontos de coleta, adotando-se os padrões de potabilidade da Portaria no 2914/2011 do Ministério da Saúde do Brasil. Os resultados demostraram que algumas amostras apresentaram valores inadequados com pH abaixo de 6, consideradas águas ácidas, turbidez acima de 5 UNT, ferro acima de 0,3 mg/L, cloreto superior a 250 mg/L e nitrato com valores elevados, acima de 10 mg/L N-NO3, além de todas as amostras avaliadas nos parâmetros microbiológicos manifestaram a presença de bactérias do grupo dos Coliformes Fecais, não sendo aprovadas pela Portaria supracitada, já que tais águas podem apresentar risco a saúde humana.
10

Vulnerabilidade dos recursos hídricos subsuperficiais na área urbana central do município de Araçatuba-SP /

Furtado, Zeide Nogueira de Camargo. January 2008 (has links)
Resumo: A intensificação da ocupação do solo e dos usos múltiplos dos recursos hídricos subterrâneos, nas áreas urbanas, vem comprometendo a qualidade natural das águas subterrâneas. Na zona central urbana do município de Araçatuba (SP), área de interesse do estudo de pesquisa, a exploração dessas águas por atividades comerciais e residenciais (solução alternativa de consumo) é elevada e apresenta um acréscimo acentuado em virtude do aumento populacional e desenvolvimento econômico da região. Localmente, o recurso hídrico subterrâneo de interesse é representado pelo Aqüífero Bauru que se comporta como um aqüífero livre, cujo lençol freático encontra-se em sub-superfície, nos sedimentos inconsolidados da formação Adamantina (Grupo Bauru). Com a utilização do método GOD (FOSTER, et al. 2002) adotado nesta pesquisa, foi possível a determinação dos índices de vulnerabilidade para o aqüífero local, classificando-o como de Extrema Vulnerabilidade, nos fundos dos vales das drenagens locais (Córregos Machadinho e Machado de Mello e Ribeirão Baguaçu); e de Alta Vulnerabilidade nas áreas mais elevadas situadas ao longo dos divisores de água. A Carta de Vulnerabilidade à Contaminação dos Recursos Hídricos Subsuperficiais da área de estudo reúne informações que podem subsidiar políticas públicas de prevenção, controle e restrição do uso do solo local frente às exigências das águas subterrâneas e do planejamento urbano. / Abstract: Intensification of urban land use and multiple uses of groundwater in urban areas has been responsible by damages in groundwater quality. This study was developed in Araçatuba (SP) central urban area, where groundwater exploitation to business and residential uses is high and shows great increase due to increasing population and economic development in the region. Locally, groundwater exploitation has been developed in Bauru Aquifer, whose behaves as a free aquifer, storing water in sand poorly consolidated sediments in Adamantina Formation (Bauru groundwater exploitation). Using GOD method (FOSTER, et al. 2002), this study makes possible vulnerability indices determination for the local aquifer, resulting High Vulnerability in elevated areas such hill tops, and Extreme Vulnerability in bottom valleys of local drainage courses (e.g. Machadinho and Machado de Mello Streams, Baguaçu River). Vulnerability Chart to Natural Contamination of Groundwater the area presents information that can support public policies for prevention, control and restriction of land use, considering groundwater demands and urban planning. / Orientador: José Augusto de Lollo / Coorientador: Jefferson Nascimento de Oliveira / Banca: Milton Dall'Aglio Sobrinho / Banca: Samir Felicio Barcha / Mestre

Page generated in 0.1099 seconds