71 |
Amplitude de pulso ocular em pacientes portadores de glaucoma primário de ângulo aberto assimétricoKac, Marcelo Jarczun January 2010 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-04T13:45:33Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-10-04T13:45:45Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5) / Made available in DSpace on 2017-10-04T13:45:45Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO MARCELO JARCZUN KAC.pdf: 1310344 bytes, checksum: 894e8b8ff1bbb98f54524b2bf42cfdc9 (MD5)
Previous issue date: 2010 / Prefeitura da Cidade do Rio de Janeiro / Objetivo: Avaliar a amplitude de pulso ocular (APO) utilizando o tonômetro de contorno dinâmico (TCD) em pacientes com glaucoma primário de ângulo aberto (GPAA) assimétrico e pressão intra-ocular (PIO) assimétrica. Métodos: 48 pacientes (96 olhos) com GPAA assimétrico foram recrutados. Três medidas da PIO e da APO foram aferidas utilizando o TCD. Para o diagnóstico de assimetria eram necessárias uma diferença de perda de campo visual maior que 6 dB no índice “mean deviation” (MD), e uma diferença de 5 mmHg na PIO medida com o tonômetro de aplanação de Goldmann (TAG) entre o olho mais afetado e o contra-lateral. Todos os participantes se submeteram a um exame oftalmológico completo, incluindo paquimetria ultrassônica e ecobiometira. Os critérios de exclusão consistiram de: doenças ou cicatrizes corneanas, uso de medicação anti-glaucomatosa tópica ou sistêmica e cirurgia ocular prévia. Resultados: Não houve diferença com significância estatística (p = 0,142) entre o comprimento axial dos olhos do grupo melhor (22,95 +/- 0,91 mm) e pior (22,85 +/- 0,97 mm). Houve diferença estatisticamente significativa (p = 0,011) entre a espessura corneana central do grupo de olhos melhores (537,08 +/- 29,54 μm) e do grupo de olhos piores (534,40 +/- 29,87 μm). Os valores da APO do grupo de olhos melhores (3.32 +/- 1.14 mmHg) foram significativamente menores (p = 0,001) do que os obtidos no grupo de olhos piores (3,83 +/- 1,27 mmHg). Quando corrigimos as medidas de APO pela diferença de PIO entre os olhos houve uma perda da significância estatística entre os grupos (p = 0,996). Conclusão: A APO é semelhante entre os dois olhos de pacientes portadores de GPAA assimétrico com PIO assimétrica. De acordo com esses dados não há evidência de que a APO possa ter um papel no GPAA hipertensivo assimétrico / Aim: To evaluate ocular pulse amplitude (OPA) using the dynamic contour tonometer (DCT) in patients with asymmetric primary open-angle glaucoma (POAG) and asymmetric intra-ocular pressure (IOP). Methods: The participants consisted of 48 patients (96 eyes) with asymmetric POAG. Three measurements of IOP and OPA were taken using DCT. The diagnosis of asymmetry required a difference of glaucomatous visual field loss greater than 6 dB in the global index MD and a difference of 5 mmHg in IOP measured by Goldmann aplannation tonometry (GAT) between the more affected and the contra-lateral eye. All participants underwent full ophthalmologic clinical assessment including ultrasonic pachymetry and biometric measurements. Exclusion criteria were corneal diseases or scars, topical or systemic glaucomatous medications, and previous ocular surgery. Results: No difference (p = 0.142) was found between the axial length measurements of the better eyes group (22.95 +/- 0.91 mm) and worse eyes group (22.85 +/- 0.97 mm). There was a statistically significant difference (p = 0.011) between the central corneal thickness values of the better eyes group (537.08 +/- 29.54 μm) and worse eyes group (534.40 +/- 29.87 μm). The OPA values of the better eyes group (3.32 +/- 1.14 mmHg) were significantly lower (p = 0.001) than those obtained on worse eyes group (3.83 +/- 1.27 mmHg). When correcting the OPA readings by the IOP there was a loss of statistical difference between groups (p = 0.996). Conclusion: OPA is similar in both eyes of asymmetric hypertensive POAG patients with asymmetric IOP. According to this data there was no evidence that OPA could play a role in asymmetric hypertensive POAG
|
72 |
Supressão de bandas laterais através da técnica de rotação da amostra em torno do ângulo mágico com frequência variável / Spinning sideband suppression by variable and low magic angle spinningVidoto, Ednalva Aparecida 11 October 1995 (has links)
Em experimentos de Ressonância Magnética Nuclear (RMN) com Rotação da Amostra em Tomo do Ângulo Mágico (MAS), as bandas laterais são um problema comum na obtenção de espectros de alta resolução em sólidos. Em espectrômetros de alto campo magnético ou então, em sistemas que não dispõem de rotores de amostra de freqüência elevada, este problema é mais grave. Para facilitar a interpretação do espectro de alta resolução torna-se necessário suprimir estas bandas laterais. Nesta dissertação descrevemos um método simples de supressão das bandas laterais que consiste em variar a freqüência de rotação da amostra durante a aquisição do sinal, assim como, a instrumentação necessária para realizar esse experimento. Este método, que denominamos de Supressão das Bandas Laterais utilizando-se Freqüência de Rotação Baixa e Variável, baseia-se na dependência da posição das bandas laterais com a freqüência de rotação, reduzindo as coincidências entre suas posições durante a promediação, enquanto o sinal isotrópico permanece estável sempre no mesmo ponto do espectro. Para ilustrar a utilização dessa nova técnica, realizamos experimentos de RMN com o núcleo de 13C em amostras de hexametilbenzeno, tirosina, lignina e ácido húmico, e com o núcleo quadrupolar 79Br em amostras de KBr e NaBr + KBr / Sidebands in Magic-Angle-Spinning Nuclear Magnetic Resonance (MAS-NMR) experiments are a common problem for high field spectrometers or low spinning frequency systems. Although these sidebands may be used to gain information after they have been identified, it is necessary to eliminate then to simplify the interpretation of the spectra; we have recently succeeded in suppressing spinning sidebands by continuously varying the speed during the signal acquisition. This method, that we called variable low speed sideband suppression, relies on the speed dependent of the sideband positions. The purpose of this work is to describe a simple method and apparatus to suppress spinning sidebands in MAS-NMR experiments. The method allows a quick acquisition of the isotropic chemical shift spectra and works well even when the highest available spinning cannot clearly resolve the spinning sidebands. To illustrate the method, we present the 13C MAS-NMR spectra of a variety of sample acquired using cross-polarization and high power proton decoupling. Among the samples studied were: hexamethylbenzene, tyrosine, lignin and humic acid. And quadrupolar nuclei 79Br in the samples Kbr and NaBr + KBr
|
73 |
Influência do ângulo entre a crista óssea e a superfície radicular na profundidade do sulco gengival clínico / Influence of the angle between the bone crest and root surfaces in the depth of the clinical gingival sulcusAlvarez, Carlos Federico Franco 26 October 2011 (has links)
Foi desenvolvido projeto de pesquisa clínica e radiográfica para avaliar a influência do ângulo formado entre a superfície dental e a crista óssea na determinação da profundidade de sondagem do sulco gengival e complementarmente no comportamento da margem gengival por vestibular de dentes molares inferiores inclinados para mesial. Para tanto foram incluídos 30 sítios mesiais e 30 distais no grupo teste, com igual número de sítios controles de molares inferiores com inclinação normal. Nos dentes que forneceram esses sítios também foi feita a determinação da profundidade do sulco gengival na região vestibular central do dente, identificando-se a qualidade e quantidade de gengiva ceratinizada, respectivamente pela metodologia de Kan et al. (2010) e pela mensuração com sonda periodontal da distância da margem gengival à junção mucogengival. Foram incluídos pacientes periodontal e sistemicamente saudáveis, excluindo-se pacientes que tivessem sido submetidos a procedimentos ósseos regenerativos prévios nas áreas de interesse, diabéticos relutantes ao controle médico, usuários de drogas e/ou álcool, portadores de alterações sistêmicas que interfiram no metabolismo ósseo (como por exemplo, osteoporose e hiperparatireoidismo). Os exames foram realizados por examinador competente, devidamente calibrado. Para análise radiográfica as imagens foram transferidas para o computador, realizando-se as mensurações dos ângulos interessados com o programa de computador MB-Ruler Pro (MB-Software solutions). A análise estatística foi realizada no programa GraphPad Prism versão 5.03 para Windows (GraphPad, Usa). Os resultados obtidos em linhas gerais mostraram que houve influência significativa do ângulo entre a superfície dental e a crista óssea (p > 0,0001) na determinação do sulco gengival proximal em áreas de dentes inclinados, porém não há essa influência na profundidade de sondagem do sulco gengival por vestibular para áreas com qualidade e quantidade de gengiva comparáveis ao controle (p=0,08). A despeito desses resultados, não se encontrou correlação definida entre nenhum dos parâmetros de interesse analisados. Dentro dos limites do estudo os resultados também evidenciaram que, embora possam ocorrer variações desses parâmetros, a saúde periodontal pode ser mantida pelo indivíduo nas condições analisadas. / A clinical and radiographic research project was developed to assess the influence of the angle formed between the tooth surface and the alveolar bone crest in determining the probing depth of the gingival sulcus and complementary also to evaluate the behavior of the buccal gingival margin of mesially inclined molars. Therefore, 30 mesial and 30 distal sites of inclined lower molars were included in the test group, with an equal number of sites of lower molars with normal inclination in the control group. In addition in all the teeth of both test and control groups the depth of the clinical gingival sulcus at the central buccal region of the tooth was assessed by measuring with a periodontal probe, identifying the quality of the keratinized gingiva through the methodology of Kan et al. (2010) and determining the width of keratinized gingiva by measuring the distance from the free gingival margin to the mucogingival junction. The study was done in systemic and periodontally healthy individuals, excluding patients who had undergone bone-regenerative procedures in the areas of interest, diabetics reluctant to medical control, alcohol and / or drug users, and individuals suffering from systemic conditions that might interfere with bone metabolism (like osteoporosis and hyperparathyroidism). The examinations were performed by a competent and properly calibrated examiner. The radiographic images were then transferred to a computer in order to analyze the measurements of the involved angles with the computer program MB-Ruler Pro (MB-Software solutions). Statistical analysis was performed using GraphPad Prism version 5.03 for Windows (GraphPad, Usa). The results in general showed that there was significant influence of the angle between the tooth surface and the alveolar bone crest on the depth of the gingival sulcus in proximal areas of inclined teeth (p > 0,0001), but there was no such influence in the probing depth of the buccal gingival sulcus of these inclined molars provided that the quality and quantity of gingiva were similar to controls comprised by molars with normal inclination (p=0,08). Despite this significance, there was no definite correlation between any of the analyzed parameters of interest. The results also showed that, although there may be variations of these parameters, within the limits of this study the conditions of periodontal health can be maintained by the individual.
|
74 |
FREEFLOW-AXI: um ambiente de simulação de escoamentos axissimétricos com superfícies livres. / FREEFLOW-AXI: an axisymmetric free surface flow simulation system.Oliveira, Maria Luísa Bambozzi de 28 June 2002 (has links)
Este trabalho apresenta um ambiente de simulação de escoamentos com simetria radial e superfícies livres, baseado no sistema Freeflow. O sistema é formado por três módulos: um modelador de moldes, um simulador e um visualizador de escoamentos. O simulador implementa o método GENSMAC para a solução das equações de Navier-Stokes em coordenadas cilíndricas, utilizando diferenças finitas em uma malha diferenciada. São introduzidos os efeitos da tensão superficial e do ângulo de contato nas simulações com simetria radial. Alguns resultados de simulações utilizando este sistema e uma validação do código são apresentados, comparando simulações com soluções analíticas e experimentais, e estudando a convergência do método. / This work presents an environment for the simulation of axisymmetric free surface flows, based on the Freeflow system. The system contains three modules: a geometric model modeller, a simulator and a visualizator. The simulator implements the GENSMAC method for the solution of the Navier-Stokes equations in cylindrical coordinates, using finite differences in a staggered grid. The effects of surface tension and contact angle are introduced in the axisymmetric simulations. Some results from simulations using this system and a validation of the code are presented, comparing the simulations with analytical and experimental solutions, and studying the convergence of the method.
|
75 |
Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems. / Modelagem e metodologia aplicadas a avaliação da performance de sistemas mult-infeed de transmissão HVDC.Pedroso, Felipe Rocha Velloso de Almeida 30 August 2017 (has links)
The Brazilian transmission system covers a large area, with a high concentration of consumer centres in the Southeast region and abundant hydro generation in the North. To connect these regions, some of the transmission lines might reach 2500 km length, creating a challenging situation. In this context, system planners have been defining the use of HVDC systems as the most feasible choice of transmission investment. It is so, recognized that the connections of power plants in the Northern region to the load centres in the Southeast will require a significant number of bipoles and, until the present moment, all the operational and planned HVDC lines are based on the converter technology known as LCC (Line Commutated Converter) and consequently subject to commutation failure. Currently, the Brazilian system has four LCC bipoles, with two other bipoles under construction. Although the Southeast grid is strong, the connection of two additional bipoles is a concern as the interaction between these inverters may cause strong effects on one another, a phenomenon known as multi-infeed interaction. In such a situation, the assessment of the system operation, possible outages and possible mitigation methods are of paramount importance. This document presents a different methodology for the analysis of the multi-infeed system mentioned and focuses on its validation by analysing operation under normal conditions and with the implementation of established mitigation methods. The investigation was carried out with EMT, power flow, short-circuit and electromechanical softwares in a very large AC system composed by 100 buses on EMT and full Brazilian system on the rest. The effects of faults were analysed and the areas containing the buses where a fault leads to multiple commutation failures were identified. / O sistema de brasileiro de transmissão abrange uma área ampla, com uma alta concentração de consumo na região Sudeste e abundante geração hidrelétrica no Norte. Para conectar essas regiões, algumas das linhas de transmissão podem alcançar comprimentos de 2500 km, criando uma situação desafiadora. Neste contexto, os planejadores de sistemas têm definido o uso de sistemas HVDC como a escolha mais viável de investimento em transmissão. É então reconhecido que as conexões de usinas na região Norte aos centros consumidores no Sudeste exigirão um número significativo de bipolos e, até o momento presente, todas as linhas HVDC operacionais e planejadas são baseadas na tecnologia de conversão conhecida como LCC (Line Commutated Converter) e consequentemente sujeito a falha de comutação. Atualmente, o sistema brasileiro tem quatro bipolos LCC, com outros dois bipolos em construção. Embora a rede do Sudeste seja considerada forte, a conexão de dois bipolos adicionais é uma preocupação, pois a interação entre esses inversores pode causar efeitos danosos uns sobre os outros, um fenômeno conhecido como interação multi-infeed. Em tal situação, a avaliação da operação do sistema, possíveis interrupções e possíveis métodos de mitigação são de suma importância. Este documento apresenta uma metodologia diferente para a análise do sistema multi-infeed mencionado e foca em sua validação, analisando a operação em condições normais e com a implementação de métodos de mitigação conhecidos. A investigação foi realizada com softwares EMT, de curto circuito, fluxo de potência e estabilidade eletromecância em um sistema CA muito grande composto por 100 barras em EMT e sistema brasileiro completo no resto. Os efeitos das falhas foram analisados e as áreas que contêm as barras onde uma falha leva a múltiplas falhas de comutação foram identificadas.
|
76 |
Mensuração do eixo mecânico e determinação do alinhamento do membro pélvico em cães com luxação de patela: estudo radiográfico no plano frontal e correlação com a fisiopatologia da doença / Measurement of the mechanical axis and determination of pelvic limb alignment of dogs with patellar luxation: radiographic study in the frontal plane and its correlation with the physiopathology of the diseaseGaleazzi, Viviane Sanchez 26 January 2016 (has links)
O mal alinhamento do membro pélvico de cães contribui para o desenvolvimento ósseo anormal e deslocamento medial ou lateral do aparelho extensor do quadríceps. De acordo com o aumento da incidência da luxação de patela em cães de médio e grande porte, o estudo do alinhamento do membro pélvico e das deformidades ósseas associadas recebeu destaque. Assim, o conhecimento do eixo mecânico e do alinhamento do membro pélvico, bem como de seus ângulos articulares no plano frontal, é essencial para o diagnóstico, classificação, quantificação do grau de desvio, e para o delineamento do tratamento cirúrgico corretivo. O presente estudo teve como objetivo mensurar e correlacionar os ângulos articulares do fêmur e da tíbia com o diferentes graus de luxação de patela. Foram obtidos exames radiográficos independentes do fêmur e da tíbia, nas projeções craniocaudal e caudocranial, respectivamente, de cães com e sem luxação de patela. As imagens radiográficas foram processadas digitalmente produzindo 92 exames radiográficos do membro pélvico em extensão total que foram divididos em grupos controle e luxação de patela. O grupo luxação foi subdividido de acordo com o tipo de luxação, medial ou lateral. Foram determinados os ângulos articulares, alinhamento e o eixo mecânico do membro pélvico correlacionando os resultados com a luxação de patela. Concluiu-se que o grau de luxação de patela interferiu na magnitude do desvio do eixo mecânico e no valor do ângulo mecânico femorotibial, e que o valor do ângulo mecânico lateral distal do fêmur foi maior nos cães com luxação de patela, sugerindo a presença de deformidade femoral distal. / The misalignment of the pelvic limb dogs contributes to abnormal bone development and medial or lateral displacement of the extensor mechanism. Increased incidences of the patellar dislocation in medium and large dogs stimulated alignment study and the associated bone deformities. Thus, knowledge of the mechanical axis and the pelvic limb alignment, as well as their joint angles in the frontal plane is essential for the diagnosis, classification, quantification of the degree of deviation and for the design of corrective surgery. The purpose of this study was to measure the femoral and tibial articular angles and and assess the relationship between it and the different degrees of patellar luxation. Independent radiographs of the femur and tibia of dogs with or without patellar luxation were obtained in the craniocaudal and caudocranial projections, respectively. The radiographic images were digitally processed producing 92 x-ray exams of the pelvic limb in full extension that were divided into control and patella luxation groups. The patellar luxation group was divided according to the type of dislocation, medial or lateral, and dislocation grade. The joint angles, alignment and the mechanical axis of the pelvic limb were determined and the results were correlated with the disease. In conclusion, the degree of patellar dislocation interfered with the magnitude of the mechanical axis deviation and the value of mechanical femorotibial angle, the value of the mechanical lateral distal femoral angle was higher in dogs with patellar dislocation, suggesting the presence of femoral distal deformity.
|
77 |
Estudo comparativo do ângulo de contato em tecidos de malha de poliamida tratados com plasma / Comparative study of the contact angle in knitted fabrics of polyamide treated with plasmaGondim, Maurício Lopes 03 August 2016 (has links)
Dentre as técnicas de modificação de propriedades das superfícies aplicadas na indústria, o tratamento por plasma é amplamente utilizado. Diversos estudos têm sido realizados, sobretudo na última década, analisando artigos têxteis de diferentes fibras quanto a melhoria das funcionalidades. O objetivo deste trabalho é estudar comparativamente as propriedades de umectação de tecidos de malha de poliamida 6.6 com elastano antes e após aplicação de descarga plasmática de dupla barreira dielétrica. As malhas foram fabricadas utilizando-se como matérias-primas fios e poliamida e de elastano. Os tecidos receberam a aplicação do tratamento de plasma, com potências de 1,2 e 1,5 kW. Foram realizadas três leituras de ângulo de contato dinâmico: logo após o tratamento, 2 horas após o tratamento e 24 horas após o tratamento. Foi feita uma única leitura em uma das amostras antes de submetê-la ao tratamento (controle). No tingimento das amostras foram utilizados corantes ácidos e reativos e realizados ensaios de solidez à lavagem e solidez da cor à lavagem doméstica. Observou-se uma redução significativa no valor do ângulo de contato das amostras tratadas com plasma, aumentando a capacidade de absorção do tecido de malha / Among the surfaces of the property modifying techniques used in the industry, plasma treatment is widely used. Several studies have been conducted, especially in the last decade, analyzing textiles articles of different fibers and improved features. The target of this job is study comparatively the wetting properties of polyamide 6.6 knitted fabrics with spandex before and after application of plasma discharge double dielectric barrier. The knitting were produced using as raw materials polyamide yarn and elastane. Fabrics received application of plasma treatment with potencies of 1.2 and 1.5 kW. three readings dynamic contact angle were made: immediately after treatment, 2 hours after treatment and 24 hours after treatment. a single reading was done on a sample before submitting it to treatment (control). In the dyeing of the samples were used acids and reactive dyes and performed strength tests to washing and color fastness to domestic laundering. a significant decrease was observed in the value of the contact angle of the samples treated with plasma, increasing the absorption capacity of the knitting fabric
|
78 |
Análise estrutural e de superfície de madeiras submetidas a tratamento térmico e degradadas pelo fungo Pycnoporus sanguineus / Structural analysis and surface of wood heat-treated and degraded by the fungus Pycnoporus sanguineusSantos, Sabrina Nicoleti Carvalho dos 17 July 2015 (has links)
Neste trabalho, analisou-se como o tratamento térmico e a degradação pelo fungo de podridão branca influenciaram as propriedades dos componentes das amostras de madeira das espécies Araucaria sp., Pinus sp., Erisma sp. e Hymenaea sp.. Essas amostras foram cortadas em diferentes planos de corte e submetidas inicialmente a um teor de umidade de equilíbrio de 12%. As caracterizações das amostras foram realizadas empregando a técnica de ângulo de contato, medidas de perda de massa (somente para amostras degradadas pelo fungo), a análise dinâmico-mecânica (DMA) e difração de raios X. Para as amostras degradadas pelo fungo, o valor de perda de massa foi maior para a espécie Pinus sp. e menor para Hymenaea sp.. Os difratogramas de raios X apontaram que o corte transversal apresentou um caráter mais amorfo em relação ao corte longitudinal. As medidas de ângulo de contato mostraram que com o aumento da temperatura de tratamento térmico a superfície se tornou mais hidrofóbica. O mesmo comportamento foi verificado para amostras submetidas à degradação pelo fungo. De forma que, tanto o tratamento térmico quanto a degradação pelo fungo, ocasionaram um aumento de grupos não-polares presentes na superfície. Já nas medidas de DMA foi observado que o módulo de armazenamento (E\') diminuiu com o aumento da temperatura. E o grau de mobilidade das cadeias poliméricas foi analisado por meio das temperaturas de transições vítreas das hemiceluloses e lignina (Tg), bem como, as relaxações secundárias através do fator de perda (tan δ). Esses resultados possibilitam uma maior elucidação sobre como o tratamento térmico e a degradação fúngica afetam diferentes tipos de amostras de várias espécies de madeira, essas informações são relevantes para a utilização e preservação dessas madeiras. / The present dissertation addresses the analysis of the influence of heat treatment and degradation by white rot fungus on the properties of the components of wood species Araucaria sp., Pinus sp., Erisma sp. and Hymenaea sp. Samples were cut at different cutting plans and initially subjected to a 12% equilibrium moisture content. They were then characterized by a contact angle technique, weight loss measurements (for samples degraded by the fungus), dynamic mechanical analysis (DMA) and X-ray diffraction. The mass loss values of samples degraded by the fungus were higher for Pinus sp. and lower for Hymenaea sp. The X-ray diffraction showed the transversal cut had an amorphous character in relation to the longitudinal cut. According to the contact angle measurements, showed that with increasing heat treatment temperature over the surface became hydrophobic. The same behavior was observed for samples submitted to degradation by fungus. In order, that both heat treatment and degradation by the fungus, caused an increase of non-polar groups on the surface. The DMA measurements showed the storage modulus (E\') decreases with increasing temperature. The degree of mobility of the polymer chains was analyzed through glass transition temperatures of hemicelluloses and lignin (Tg) and the secondary relaxations were assessed through the loss factor (tan δ). The results enabled greater elucidation on how the heat treatment and fungal degradation affect different types of samples of various wood species. Such information is relevant for the use and preservation of woods.
|
79 |
Método FD-BPM semivetorial de ângulo largo para a análise de estruturas tridimensionais utilizando a técnica ADI / not availableNascimento, Valtemir Emerencio do 28 June 2002 (has links)
O projeto de dispositivos ópticos integrados é de fundamental importância no desenvolvimento de sistemas de comunicações ópticas. Por esse motivo, várias técnicas de modelamento para estes dispositivos tem surgido na literatura. Esta corrida em direção à sofisticação das ferramentas de modelamento decorre da evolução natural dos processos de fabricação, que tem permitido a construção de estruturas com geometrias bastante complexas. Dentre as várias técnicas utilizadas atualmente nas simulações de dispositivos fotônicos destaca-se o método da propagação do feixe (BPM). Este método apresenta como grande atrativo o fato de ser de fácil implementação e de apresentar baixa carga computacional. Inicialmente, a técnica BPM foi empregada utilizando a equação de onda escalar de Helmholtz. Esta abordagem é eficiente desde que a diferença entre os índices de refração dos materiais utilizados no guia de onda seja pequena e que a geometria da estrutura não apresente variações na direção de propagação. Entretanto, a luz é uma onda eletromagnética que possui propriedades intrinsecamente vetoriais. As propriedades vetoriais (efeitos de polarização) tornam-se importantes quando estruturas que apresentam elevado contraste de índices de refração precisam ser investigadas. Neste trabalho o fenômeno da polarização é avaliado através da utilização da equação de onda semivetorial de Helmholtz em três dimensões, a qual é desenvolvida em termos das componentes transversais de campo magnético (Formulação H). A solução da equação de onda semivetorial de Helmholtz é obtida pelo método BPM expandido em diferenças finitas (FD). Os aproximantes de Padé de ordem (1,0), equivalentes à propagação no limite paraxial, e de ordem (1,1), equivalentes à propagação em ângulo largo, são implementados e seus resultados discutidos ) A propagação do campo no FD-BPM tridimensional proposto aqui se dá através da utilização da técnica implícita das direções alternadas (ADI), a qual proporciona uma ótima estabilidade com baixo esforço computacional. A validação deste método é feita através da simulação de guias de onda tipo rib, avaliando parâmetros numéricos como: passo de propagação longitudinal, largura da gaussiana de excitação inicial, passo de discretização transversal, número de iterações e índice de referência. Adicionalmente, também é investigada uma fibra óptica com geometria tipo D. Estes resultados serão comparados com os resultados existentes na literatura para estas estruturas a fim de garantir a eficácia do método. / It is well known that finite difference beam propagation methods have been a valuable tool for the simulation of a large variety of optical waveguides structures such as: Mach-Zehnder, Y junctions, directional couplers, switches, etc. The increasing complexity of these structures, either in terms of geometry or material composition, requires more accurate modeling techniques. Among the several techniques available nowadays the beam propagation method (BPM) is maybe the most celebrated one. This method has attracted a great deal of attention by virtue of its ease of implementation and low computational effort. Initially, the BPM was applied to solve the scalar Helmholtz equation. This approach can be quite efficient for waveguides exhibiting low refractive index contrast and no variation along the longitudinal direction. Light, by its turn, is an electromagnetic wave with intrinsically vectorial properties. The vectorial properties (polarization effects) become very important when high contrast and longitudinally varying structures are involved. In this work the polarization phenomenon is evaluated by means of the three-dimensional semivectorial Helmholtz equation, which is solved in terms of its transverse magnetic field components (H formulation). The solution of this semivectorial equation is obtained via the finite difference BPM method expanded in terms of the following Padé approximants: Padé(1,0), equivalent to the semivectorial equation in the paraxial limit, and Padé (1,1), the wide angle solution. The field propagation dynamics in both cases is performed via alternate direction implicit method (ADI), which provides good numerical stability and low computational effort. As far as the authors know, this is the first time that a wide-angle formalism based on Padé(1,1) and ADI technique is proposed to solve the semivectorial Helmholtz equation. The validation of this new wide-angle method is performed for three well known rib waveguides structures available in the literature, and its accuracy measured in terms of the following parameters: longitudinal step size, initial field (gaussian) width, transversal step size, iteration number, and reference refractive index. A D-shaped fiber is also investigated with this method for comparison purposes. The results obtained in all cases are checked against those available in the literature in order to guarantee the efficiency of the method.
|
80 |
Avaliação morfológica e morfométrica da articulação coxofemoral do buldogue inglês / Morphological and morphometric evaluation of hip joint from English BulldogFerrante, Bruno 06 May 2016 (has links)
A displasia coxofemoral é a afecção ortopédica mais frequente na espécie canina e, pela estatística apresentada pela Orthopaedic Foundation for Animals o buldogue inglês é a raça com maior acometimento proporcionalmente. Entretanto carece em literatura dados sobre o desenvolvimento e morbidade desta doença na raça. O objetivo desse estudo foi avaliar a morfologia e morfometria da articulação coxofemoral de cães da raça buldogue inglês por meio de exame radiográfico e por tomografia computadorizada comparando-os com achados da avaliação ortopédica e cinética. A hipótese proposta é de que buldogues podem apresentar alterações radiográficas compatíveis com a displasia coxofemoral sem apresentar manifestações clínicas da doença. De cada articulação avaliada foram adquiridos dados por meio de exame ortopédico, avaliação cinética, radiográfica e por tomografia computadorizada. Foram feitas avaliação subjetiva das alterações morfológicas radiográficas e aferição do ângulo de Norberg, ângulo de inclinação do colo femoral e o escore de subluxação dorsolateral. Os dados obtidos foram correlacionados por meio dos coeficiêntes de Spearman. Trinta cães foram avaliados, 20 machos e 10 fêmeas. As médias de idade e peso dos participantes do estudo foram de 3,5 anos e 26,1 kg respectivamente. 76,6% dos animais apresentaram escore de condição corporal acima do considerado ideal e 63,3% viviam em ambiente de piso liso. Entretanto esses fatores de risco avaliados não apresentaram correlação com nenhuma alteração pesquisada. 63,3% dos cães apresentaram alterações nas articulações dos joelhos e 40% nas articulações coxofemorais pela avaliação ortopédica. Pela palpação da articulação coxofemoral foram observadas alterações em 50% dos animais, sendo a crepitação leve representando 86,6% das alterações, e crepitação de grau moderado e discreta manifestação de dor em 13,3%. A frequência de alterações morfológicas radiográficas observada foi de 98,3% para subluxação coxofemoral, 81,6% para o achatamento da cabeça do fêmur, 70% para presença de osteófitos ou entesófitos periarticulares e 61,1% para o arrasamento acetabular. A conformação radiográfica da articulação coxofemoral mais frequente foi de cabeça femoral com formato discretamente elíptico e discretamente subluxada, bordas acetabulares craniolateral arredondada e dorsal encurtada com discreta presença de osteófitos. A média das mensurações morfológicas obtidas no estudo foram abaixo dos valores considerado de normalidade, sendo de 94,94° para o ângulo de Norberg, 27,13% para o escore de subluxação dorsolateral e 128,53° para o ângulo de inclinação do colo femoral. A presença de osteófitos periarticulares obteve correlação estatística com presença de crepitação à palpação da coxofemoral, assim como o arrasamento acetabular com a presença de dor ao exame ortopédico. Entretanto as manifestações clínicas não coincidiram proporcionalmente às alterações observadas pelos métodos de diagnóstico por imagem. É questionado se a conformação muscular da raça pode contribuir para contrabalancear a instabilidade articular apresentada pelos métodos avaliados / Hip dysplasia is the most common orthopedic disorder in dogs, and the statistics presented by the Orthopedic Foundation for Animals English Bulldog is the race with most animals affected proportionately. However it lacks in literature data of the development and morbidity of this disease in the race. The aim of this study was to evaluate the morphology and morphometry of the hip joint of English Bulldogs through radiographic examination and computed tomography comparing them with findings from orthopedic and kinetic evaluation. The hypothesis proposed is that Bulldogs may have radiographic changes compatible with hip dysplasia without showing clinical symptoms of the disease. From each joint evaluated were acquired data through orthopedic examination, and kinetics, radiographic and computed tomography evaluations. They were made subjective evaluation of radiographic morphological changes and measuring the Norberg angle, femoral neck inclination angle and the dorsolateral subluxation score. The data were correlated by the Spearman\'s rank. Thirty dogs were evaluated, 20 males and 10 females. The mean age and weight of the study participants was 3.5 years and 26.1 kg respectively. 76.6% of the animals had a body condition score considered above ideal and 63.3% lived in flat floor environment. However, these risk factors evaluated were not correlated with any changes searched. 63.3% of dogs showed changes in knee joints and 40% in hip joints by the orthopedic evaluation. Abnormalities were observed in 50% of animals by palpation of the hip joint, the slight crackle representing 86.6% of the changes, and moderate crackle and mild degree manifestation of pain in 13.3%. The frequency of morphological radiographic changes observed was 98.3% for hip subluxation, 81.6% for the femoral head flattening, 70% for the presence of periarticular osteophytes or entesophytes and 61.1% for the acetabular razing. The most common radiographic conformation of the hip joint was femoral head slightly elliptical shape and discreetly subdisluxated, rounded craniolateral acetabular edge and shrtened dorsal edge with discreet presence of osteophytes. The average morphological measurements obtained in the study were below the values considered normal, being 94.94° for the angle of Norberg, 27.13% for dorsolateral subluxation score and 128.53° for inclination angle of the femoral neck. The presence of periarticular osteophytes have statistical correlation with the presence of ckakle on palpation of the hip joint, as well as the acetabular razing with the presence of painful on orthopedic examination. However the clinical manifestations were not proportionaly coincidence with the changes observed by the diagnostic imaging methods. It questioned whether the muscle conformation of the race can help to counteract the instability joint presented by the evaluated methods
|
Page generated in 0.0439 seconds