Méthodologie de dimensionnement sur cycle de vie d'une distribution en courant continu dans le bâtiment : applications aux câbles et convertisseurs statiques DC/DC

Jaouen, Cédric, Jaouen, Cédric 09 July 2012 (has links) (PDF)
Avec l'apparition des systèmes PV en toiture et des véhicules électriques, le nouveau contexte énergétique au sein du bâtiment pose, sous un nouvel angle, la question de la distribution en courant continu au sein des bâtiments. Mais comment évaluer objectivement l'intérêt d'un réseau DC ? Dans un contexte où l'énergie et les impacts environnementaux prennent chaque jour plus d'importance, la quantification des performances d'un tel système selon sa seule phase d'usage ne répond pas complètement à la question son impact global. C'est pourquoi nous proposons d'aborder la question via l'éco-dimensionnement des composants constituant ce système. Pour simplifier un problème fondamentalement complexe (multi-critères), nous avons choisi d'effectuer ces dimensionnements sur la base de la minimisation de leur consommation d'énergie primaire sur l'ensemble de leur cycle de vie (pertes + énergie grise = Gross Energy Requirement GER). L'un des objectifs étant d'apporter à la fois une méthodologie mais aussi les premiers éléments qui permettront de déterminer un optimum du niveau de tension d'une distribution en courant continu dans les bâtiments.
2

Méthodologie de dimensionnement sur cycle de vie d’une distribution en courant continu dans le bâtiment : applications aux câbles et convertisseurs statiques DC/DC / Sizing methodology on the entire life cycle for building DC distribution : application on wiring and DC/DC converters

Jaouen, Cédric 09 July 2012 (has links)
Avec l’apparition des systèmes PV en toiture et des véhicules électriques, le nouveau contexte énergétique au sein du bâtiment pose, sous un nouvel angle, la question de la distribution en courant continu au sein des bâtiments. Mais comment évaluer objectivement l’intérêt d’un réseau DC ? Dans un contexte où l’énergie et les impacts environnementaux prennent chaque jour plus d’importance, la quantification des performances d’un tel système selon sa seule phase d’usage ne répond pas complètement à la question son impact global. C’est pourquoi nous proposons d’aborder la question via l’éco-dimensionnement des composants constituant ce système. Pour simplifier un problème fondamentalement complexe (multi-critères), nous avons choisi d’effectuer ces dimensionnements sur la base de la minimisation de leur consommation d’énergie primaire sur l’ensemble de leur cycle de vie (pertes + énergie grise = Gross Energy Requirement GER). L’un des objectifs étant d’apporter à la fois une méthodologie mais aussi les premiers éléments qui permettront de déterminer un optimum du niveau de tension d’une distribution en courant continu dans les bâtiments. / Since the development of roof PV systems and electric vehicles, the use of DC distribution for building has to be explored. However, an objective criterion has to be used to evaluate the interest of such distribution. While energy consumption and environmental impact criteria gain in importance, the performance quantification of such system over the use phase is not sufficient to illustrate its whole impact. That’s why we propose to tackle this evaluation through the eco-sizing of distribution component. In order to simplify this complex problem, based on a multi-criterion approach, we propose to size the components based on the minimization of their primary energy consumption over their entire life cycle. The resulting Gross Energy Requirement GER includes the embodied energy and the losses during the use phase. The objectives are to propose a methodology to determine the optimal voltage level for the building DC distribution, and also to illustrate the proposed approach from case studies. This methodology is applied on wiring and DC/DC converters.
3

L'expansion phénotypique et ses limites

Berthelot, Geoffroy 12 November 2013 (has links) (PDF)
Le développement futur des performances sportives est un sujet de mythe et de désaccord entre les experts. Un article, publié en 2004, a donné lieu à un vif débat dans le domaine universitaire. Il suggère que les modèles linéaires peuvent être utilisés pour prédire -sur le long terme- la performance humaine dans les courses de sprint. Des arguments en faveur et en défaveur de cette méthodologie ont été avancés par différent scientifiques et d'autres travaux ont montré que le développement des performances est non linéaire au cours du siècle passé. Une autre étude a également souligné que la performance est liée au contexte économique et géopolitique. Dans ce travail, nous avons étudié les frontières suivantes: le développement temporel des performances dans des disciplines Olympiques et non Olympiques, avec le vieillissement chez les humains et d'autres espèces (lévriers, pur sangs, souris). Nous avons également étudié le développement des performances d'un point de vue plus large en analysant la relation entre performance, durée de vie et consommation d'énergie primaire. Nous montrons que ces développements physiologiques sont limités dans le temps et que les modèles linéaires introduits précédemment sont de mauvais prédicteurs des phénomènes biologiques et physiologiques étudiés. Trois facteurs principaux et directs de la performance sportive sont l'âge, la technologie et les conditions climatiques (température). Cependant, toutes les évolutions observées sont liées au contexte international et à l'utilisation des énergies primaires, ce dernier étant un paramètre indirect du développement de la performance. Nous montrons que lorsque les indicateurs des performances physiologiques et sociétales -tels que la durée de vie et la densité de population- dépendent des énergies primaires, la source d'énergie, la compétition inter-individuelle et la mobilité sont des paramètres favorisant la réalisation de trajectoires durables sur le long terme. Dans le cas contraire, la grande majorité (98,7%) des trajectoires étudiées atteint une densité de population égale à 0 avant 15 générations, en raison de la dégradation des conditions environnementales et un faible taux de mobilité. Ceci nous a conduit à considérer que, dans le contexte économique turbulent actuel et compte tenu de la crise énergétique à venir, les performances sociétales et physiques ne devraient pas croître continuellement.