Spelling suggestions: "subject:"óssea""
21 |
Estudo comparativo entre os metodos de estimativa da idade ossea de Greulich & Pyle e Tanner & WitehouseLeite, Christiana Cordeiro 31 July 1997 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T15:00:53Z (GMT). No. of bitstreams: 1
Leite_ChristianaCordeiro_M.pdf: 3506134 bytes, checksum: 8807e48308a1dc307b90ac663c859490 (MD5)
Previous issue date: 1997 / Resumo: O presente estudo teve como objetivo verificar se os métodos de estimativa da idade óssea de GREULICH & PYLE e TANNER & WHITEHOUSE, utilizando radiografias de mão e punho, poderiam ser aplicados à população brasileira, e qual destes métodos seria o mais confiável, quando comparados à idade cronológica do indivíduo. A amostra estudada constituiu-se de 16.0 indivíduos pré-escolares e escolares brasileiros, leucodermas, residentes na cidade de Piracicaba, São
Paulo, de ambos os sexos, com idades variando de 6 anos e 10 meses a 14 anos e 9 meses, divididos em 16 faixas etárias e por sexo. Os resultados obtidos permitiram-nos concluir que, mesmo tendo sido propostos para populações diferentes da população em estudo, os métodos de estimativa da idade óssea de GREULICH & PYLE e TAN NER & WHITEHOUSE, apresentaram altas correlações, quando comparados com a idade cronológica. Ainda, foram estabelecidos fatores
de correção, de modo à tomá-los aplicáveis à população em estudo / Abstract: The purpose of this study was to verify whether the GREULICH & PYLE and T ANNER & WHITEHOUSE methods for estimating skeletal age, using hand and wrist radiographs, could be applied for the brazilian population; and which of tl;1ese two methods could be considered more reliable when compared to the chronological age of the individuals.
One hundred sixty pre schoolers and school aged, leucoderms, brazilians, living in the city of Piracicaba, São Paulo, of both sexes, with ages between 6 years, 10 months and 14 years, 9 months; alI subdivided in 16 age and sex groups.
The results obtained, allowed us to conclud that the GREULICH & I PYLE and T ANNER & WHITEHOUSE methods for estimating skeletal age, presented high interrelations when compared with chronological age of individuals. Correction factors were established to make these methods applied to brazilian population / Mestrado / Radiologia / Mestre em Ciências
|
22 |
Ação do laser de HeNe na osteogeneseFreitas, Ivania Garavello Forte 29 July 2018 (has links)
Orientadores : Vitor Baranauskas, Maria Alice da Cruz-Hofling / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:14:27Z (GMT). No. of bitstreams: 1
Freitas_IvaniaGaravelloForte_D.pdf: 3975298 bytes, checksum: 5fbdfa3f96bb2f89e7d7e4c148fce14c (MD5)
Previous issue date: 2001 / Doutorado
|
23 |
Avaliação intra e interobservadores de dois metodos de estimativa da idade ossea : Greulich & Pyle e Tanner & Whitehouse 3Villalobos, Ana Isabel Ortega 03 August 2018 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T06:02:17Z (GMT). No. of bitstreams: 1
Villalobos_AnaIsabelOrtega_M.pdf: 6346993 bytes, checksum: a16bcd6604c336a7074fc787f983dcb2 (MD5)
Previous issue date: 2003 / Mestrado
|
24 |
Artrodese subtalar após fratura do calcâneo com enxerto ósseo autólogo ou xenoenxerto liofilizadoHenning, Carlo January 2010 (has links)
Resumo não disponível
|
25 |
Análise biomecânica de próteses unitárias sobre implante cone Morse em região pré-maxilar variando-se o tamanho do implante e tipo de ancoragem óssea: estudo pelo método dos elementos finitos 3-D / Biomechanical analysis of unitary prostheses on Morse taper implants in premaxillary region varying the size of the implant and type of bone anchorage: study by finite elements 3-DOliveira, Hiskell Francine Fernandes e [UNESP] 08 March 2017 (has links)
Submitted by Hiskell Francine Fernandes e Oliveira null (hiskell@hotmail.com) on 2017-03-21T20:36:23Z
No. of bitstreams: 1
Hiskell Francine Fernandes e Oliveira_Final (1).pdf: 1563425 bytes, checksum: 0d9f4fbe344020b3396b55903e91e829 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-03-22T19:09:05Z (GMT) No. of bitstreams: 1
oliveira_hff_me_araca.pdf: 1563425 bytes, checksum: 0d9f4fbe344020b3396b55903e91e829 (MD5) / Made available in DSpace on 2017-03-22T19:09:05Z (GMT). No. of bitstreams: 1
oliveira_hff_me_araca.pdf: 1563425 bytes, checksum: 0d9f4fbe344020b3396b55903e91e829 (MD5)
Previous issue date: 2017-03-08 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho teve como objetivo analisar a distribuição das tensões em próteses unitárias implantossuportadas de cone morse, em região de maxila anterior, variando o tipo de ancoragem óssea em colocação convencional, bicorticalizado e bicorticalizado com levantamento de assoalho nasal, com diferentes comprimentos do implante, sendo eles de 8,5, 10 e 11,5mm e diâmetro de 4,0 mm, através do método dos elementos finitos tridimensionais. Foram simulados 3 modelos tridimensionais maxilares da região anterior envolvendo o elemento 11, com auxílio de programas de criação de modelos a partir de tomografias, o InVesalius (CTI, São Paulo, Brasil) e programas de desenho assistido, o Rhinoceros 3D 4.0 (NURBS Modeling for Windows, USA) e o SolidWorks 2011 (SolidWorks Corp, USA). Os modelos dos blocos ósseos foram reconstruídos a partir da tomografia computadorizada, com a presença de um implante nas dimensões citadas acima, com coroa livres de metal em zircônia e cimentadas. Os modelos 3D foram exportados para o programa de elementos finitos FEMAP v.11 (Siemens Product Lifecycle Management Software Inc.USA) para discretização dos modelos, geração da malha de elementos finitos e análise posterior a processamento no programa NEiNastran 11 (Noran Engineering, Inc., USA). Foram aplicadas cargas de 178N, em ângulo de 0o, 30o e 60o, considerando-se o longo eixo do implante como referência. Os resultados foram visualizados por meio de mapas de deslocamento, tensão de von Mises, tensão Máxima Principal e microdeformação. Diante da análise de todos os mapas de tensões, os modelos bicorticais foram os que se mostraram com melhores distribuições de tensões e deformações, tanto no implante, quanto na cortical óssea onde foram travados os implantes. Os modelos simulando a técnica de levantamento de assoalho, se mostraram  semelhante ao bicortical, sendo a técnica convencional a que mostrou distribuição inferior quando comparado aos demais. Dentro das limitações deste estudo, podemos concluir que: o carregamento oblíquo gera maior estresse e deformação tanto para o implante quanto para o tecido ósseo; a técnica de implantação bicortical (associada ou não a levantamento nasal) foi mais favorável para distribuição de tensões e deformações, principalmente no tecido ósseo. / The aim of this study was to analyze the distribution of tensions in morse tapper implants supporting single crowns in the anterior region of maxilla, varying the type of bone anchorage in conventional, bicorticalized and bicorticalized placement with nasal floor elevation, and different lengths of implants (8.5, 10 and 11.5mm) with 4.0 mm of diameter, using the 3D finite element analyses. Three 3-dimensional maxillary models of the anterior region including element #11 were simulated using software InVesalius for CT Scan recomposition (CTI, São Paulo, Brazil) and CAD-software Rhinoceros 3D 4.0 (NURBS Modeling For Windows, USA) and SolidWorks 2011 (SolidWorks Corp, USA). The bone block models were reconstructed from the computed tomography, with the presence of an implant in the dimensions mentioned above, with cemented zirconium metal free crowns. The 3D models were exported to the FEMAP v.11 finite element software (Siemens Product Lifecycle Management Software Inc.) for models discretizadion, mesh generation and post-processing analysis after processing progress in the NEiNastran 11 program (Noran Engineering, Inc ., USA). Loads of 178N were applied at angle of 0º, 30º and 60º, considering the implant long axis as reference. The results were visualized by means of displacement maps, von Mises maps, Max Principal maps and microstrain. Analyzing all stress maps, the bicortical models were the ones that showed with better stress and strain distributions, both in the implant as to the cortical bone where the implants were locked. The models simulating the technique of nasal floor elevation were similar to the bicortical one, being the conventional technique the one that showed more unfavorable stress distribution. Within this study limitation it was possible to conclude that: oblique loading showed better stress and strain distribution for the implant and bone tissue; bicortical techniques (associated or not with nasal floor elevation) were more favorable to stress and strain distribution, mainly for bone tissue. / CNPq: 130312/2015-0
|
26 |
Preservação da arquitetura tecidual de alvéolos com defeito ósseo vestibular : análise clínica e tomográfica de uma série de casos /Segnini, Bruno. January 2016 (has links)
Orientador: Elcio Junior Marcantonio / Co-orientador: Fausto Frizzera Borges Filho / Resumo: O objetivo deste estudo foi avaliar em humanos a preservação do contorno do tecido ósseo e gengival após a exodontia e enxertia com matriz de colágeno suíno (mucograft), membrana de colágeno (suíno) e osso bovino desproteinizado associado a colágeno suíno (collagen). Foram selecionados 6 pacientes provenientes da clínica da Faculdade de Odontologia de Araraquara que possuíam um pré-molar, canino ou incisivo superior indicado para exodontia e que apresentaram defeito ósseo vestibular. Todos os alvéolos receberam enxerto com matriz de colágeno suíno, membrana de colágeno e osso bovino desproteinizado acrescido de colágeno. Os dados clínicos e fotográficos foram coletados ao início do estudo, aos 7, 15, 30 e 120 dias após o procedimento cirúrgico. Foram realizados exames clínicos referentes ao aspecto da área operada, altura e espessura de gengiva queratinizada, nível gengival, biotipo gengival, assim como mensurações digitais da altura de margem gengival, e das papilas mesial e distal. Para verificação da estrutura óssea e gengival inicial e após os enxertos foram realizados exames tomográficos no início do estudo e após quatro meses do procedimento cirúrgico inicial. Os resultados mostraram que a técnica promoveu um ganho de osso vestibular, dessa forma foi concluído que a manutenção do alvéolo com a associação da matriz de colágeno suíno, membrana de colágeno e osso bovino desproteinizado promoveu boa estabilidade do volume do alvéolo com aumento do osso associado a parede ve... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate in vitro the primary stability of short and conventional sized implants with different platform types and bone densities. Material and methods: 120 implants were installed in polyurethane blocks wich simulate different bone densities (bone type I and IV). The implants were divided into 10 groups according to the type of prosthetic connections (external hexagon, and morse taper) and size of the implants (conventional, short, and short-modified). Insertion torque and resonance frequency analyzes were performed. The Kruskal- Wallis test complemented by Dunn test and the Mann-Whitney test were used for statistical analysis and were applied at the confidence level of 95 % (p < 0.05). Results: The implants inserted in the blocks with density type IV had lower insertion torque than the implants placed in the blocks with density type I. Implants with conventional external hexagon had lower insertion torque than the short, and short- modified implants with cone morse taper. Additionally, when the implants with conventional external hexagon and modified morse taper were used, the resonance frequency was higher in the block with bone density I. It was also showed that the short implants with morse taper had higher resonance frequency values than the short- modified implants with morse taper implants when the implants were placed in the blocks with bone density type IV. Conclusion: Short implants have primary stability equivalent to conventional implants regardless of platform type and density of the surgical site. Activities to be undertaken it still runs the analize of short implants with 6mm in length (IC6HE groups, IC6CM, ICM6HE and ICM6CM). It will increase...(Complete abstract electronic access below) / Mestre
|
27 |
Preparation of collagen-hydroxyapatite biocomposite scaffolds by cryogelation method for tissue engineering applicationsRodrigues, Sandra Cristina Vale January 2011 (has links)
Tese de mestrado. Engenharia Biomédica. Universidade do Porto. Faculdade de Engenharia. 2011
|
28 |
Estudo experimental do polietileno poroso de alta densidade (MEDPOR) fixado ao leito cirúrgico corticalizado e decorticalizado: análise histológica em cães /Santos Júnior, Paulo Villela. January 2001 (has links)
Banca: José Roberto Sá Lima / Banca: Rogério Lacaz Netto / Banca: Paulo Sérgio Perri de Carvalho / Banca: Sylvio Alves de Aguiar / Banca: Valdemar Malet da Rocha Barros / Resumo: Com finalidade de estudar a influência do leito receptor na integração do implante de polietileno poroso de alta densidade (Medpor), foram utilizados seis cães, com dois tipos diferentes de leitos receptores, a saber: corticalizado e decorticalizado. Após trinta, sessenta e noventa dias, procedemos ao sacrifício dos animais. Foram removidos blocos de implante e osso adjacente, os quais foram processados histologicamente e submetidos à análise em laboratório utilizando coloração de hematoxilinaeozina. Os resultados obtidos mostraram que o implante de polietileno poroso de alta densidade (Medpor) não apresentou reação de corpo estranho e nem causou processo infeccioso, permitindo a neoformação óssea e conjuntiva no interior dos poros. No grupo decorticalizado houve maior integração do implante, e este foi o que permitiu maior crescimento de tecido conjuntivo e ósseo no interior dos poros / Abstract: The aim of this study was to evaluate the influence of the bed in High Density Porous Polyethylene (Medpor) implants integration. Two different kind of beds -- corticalized and decorticalized -- were made in six dogs. The animals were killed thirty, sixty and ninety days after implantation. Blocks including implant and adjacent bone were harvested, submitted to histological procedures, stained in hematoxiline-eosine and analyzed in optic microscope. The results demonstrated an absence of infection and foreign body reaction associated with High Density Porous Polyethylene (Medpor) implants. Furthermore, bony and fibrovascular ingrowth could be observed into its pores. The best integration was noted in decorticalized group, in which occurred a greater bony and fibrovascular ingrowth in comparison to the corticalized group
|
29 |
Enxertos ósseos liofilizados e impactados humano e bovino em revisão de artroplastia total de quadrilGalia, Carlos Roberto January 2004 (has links)
O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ. / This is a non-concurrent cohort trial of 63 patients (66 hips) submitted to revision total hip arthroplasty (RTHA) using impacted freeze-dried cancellous bone grafts. The study was carried out in the Orthopedics and Traumatology Unit of Hospital de Clinicas de Porto Alegre (HCPA) from May 1997 to September 2003. The main purpose of the study was to compare clinical, radiographic and scintigraphic graft incorporation capability between human and bovine freeze-dried bone grafts. Patients were divided into two groups: Group 1 (n=35) was composed of those receiving human grafts and Group 2 (n=31) of those receiving grafts of bovine source. The median follow-up was 33 months and no death or major complications occurred in this series. The grafts were purified and freeze-dried at the Tissue Bank of the HCPA. The clinical analysis was based on the score of Merle, d’Aubigné and Postel; and the radiographic analysis on the criteria of radiolucency, density, trabecula formation, migration and “cotton flock” appearance by using these parameters, isolated or combined in an established score for radiographic bone incorporation (SCORBI). Thirty-five (53%) asymptomatic patients, 18 (51%) and 17 (49%) from Groups 1 and 2 respectively, were randomly selected to be assessed by 99mTc scintigraphy, as a complementary form of image analysis. No clinical, radiographic or scintigraphic differences were observed between the groups and both groups showed around 85% of graft integration both in the acetabular and in the femoral component. These results are comparable to those reported in the literature with the use of deep-frozen grafts. Therefore, bovine and human freeze-dried grafts can be safely and adequately used in RTHA.
|
30 |
Reparação inicial de enxertos ósseos autógenos em bloco ou em particulas : estudo microscópico em mandíbula de cães /Paleckis, Laura Guimarães Pagliuso. January 2004 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Alberto Consolaro / Banca: Luis Ronaldo Picosse / Banca: Edgard Franco Moraes Júnior / Resumo: A reabsorção óssea associada à perda dos dentes por vezes impossibilita a instalação imediata de implantes dentários. Nesta circunstância, pode ser necessária a reconstrução óssea prévia, realizada por meio de enxertos ósseos autógenos. A compreensão dos fenômenos iniciais da reparação dos enxertos é fundamental para favorecer sua consolidação clínica. Neste estudo, foram realizados enxertos ósseos autógenos em bloco ou em partículas na mandíbula de 6 cães, bilateralmente. Os leitos receptores foram preparados, os blocos foram rigidamente fixados e os enxertos em partículas foram adaptados e condensados. Três animais foram sacrificados após 7 dias e os outros 3, após 14 dias. Os espécimes foram submetidos a análise microscópica. Após 7 dias, os enxertos em bloco exibiram desvitalização, com canais vasculares vazios e interface enxerto-leito constituída por um tecido conjuntivo vascularizado e rico em fibras colágenas. As partículas, desvitalizadas, foram completamente envolvidas por tecido conjuntivo, com áreas de reabsorção osteoclástica. Aos 14 dias, os blocos já eram invadidos por canais de reabsorção, e os canais vasculares de Havers e Volkmann eram alargados e revascularizados junto ao leito. As partículas foram quase completamente reabsorvidas e o tecido conjuntivo circundante já exibia áreas de neoformação óssea. As perfurações do leito e a região adjacente ao parafuso de fixação foram sede de início de osteogênese. Os resultados mostraram que a reparação inicial dos enxertos em bloco caracteriza-se por lenta revascularização a partir do leito receptor, que requer alargamento dos canais vasculares préexistentes, enquanto as partículas são rapidamente reabsorvidas. / Abstract: Sometimes, bone resorption in association with loss of teeth makes it impossible to immediately perform dental implants. Under this circumstance, previous bone reconstruction would be necessary, through autogenous bone grafts. The understanding of the initial phenomena involved with bone grafting repair is fundamental for a clinical success. In this study, block or particulate autogenous bone grafts were placed bilaterally in mandibles of dogs. The host sites were prepared, the blocks rigidly fixated, and the particulate graft s were adapted and condensed. Three animals were sacrificed after 7 days, and the other 3, after 14 days. The samples were processed for microscopic analysis. After 7 days, the grafted blocks showed devitalization and empty vessel canals. The interface between the host site and the graft presented a vascularized connective tissue rich in collagen fibers. The grafted particles were devitalized and totally embedded in connective tissue. Areas of osteoclastic resorption were noticed in this group. At 14 days, resorption lacunae could be seen in the blocks. Harvers and Volkmann canals were elongated and revascularized at the host site. The particles had already been almost resorbed, and the surrounding connective tissue presented areas of new bone formation. The perforations of the host site and the region adjacent to the fixation screw represented areas where there was a beginning of osteogenesis. The results showed that the initial repair of block grafts was characterized by slow revascularization, starting from the host site, which required enlargement of pre-existing vascular canals. On the other hand, particulate bone grafts were rapidly resorbed and replaced by areas of forming bone. / Doutor
|
Page generated in 0.0367 seconds