• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 22
  • 15
  • Tagged with
  • 62
  • 62
  • 60
  • 31
  • 31
  • 31
  • 22
  • 18
  • 11
  • 11
  • 10
  • 10
  • 10
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modellversuch zur Rekonstruktion kraniomaxillofazialer Defekte mittels individueller 3D-pulverdruckgefertigter Calciumphosphatimplantate / Pilot project for reconstruction of craniomaxillofacial defects using individual 3D powder printing manufactured calcium phosphate implants

Rödiger, Jan January 2015 (has links) (PDF)
Ziel dieser Arbeit war die Etablierung einer Prozesskette zur Herstellung anatomischer PSI aus CaPC im 3D-Pulverdruck-Verfahren. Der Modellversuch sollte die klinische Anwendung des Verfahrens simulieren und gegenüber alternativen Verfahren einordnen. Weiterhin sollten wichtige Parameter der DCP erhoben werden, um deren Eignung als KEM für PSI darzulegen. Vier Defekte eines Kadaverschädels dienten der Prüfung der Prozesskette in Hinsicht auf Präzision und Praktikabilität des Verfahrens. Grundlage der Prozesskette waren dreidimensionale CT-Datensätze der Defektsituationen, welche eine computergestützte Rekonstruktion erlaubten. Eine eigens programmierte CAD-Software berechnete die virtuellen Entwürfe der individuellen Defektdeckungen anhand kontralateraler Strukturen. Abschließend wurden die PSI im 3D-Pulverdruck-Verfahren hergestellt und am Kadaverschädel bewertet. Zur Bewertung der DCP als geeignete KEM wurden mechanische, strukturelle und thermische Eigenschaften mit gängigen experimentellen Verfahren bestimmt. Die ermittelten Druck- und Biegefestigkeiten zeigten gute Ergebnisse für nicht bis gering lasttragende Bereiche, wie sie am Gesichts- und Hirnschädel vorliegen. Ebenso konnte die stabile Integration der Implantate durch osteosynthetische Fixierung im Schraubenausreißversuch nachgewiesen werden. Vorangegangene Untersuchungen zum klinischen Verhalten der Materialien konnten gute osteokonduktive Eigenschaften herausstellen und machen diese zu einer potentiellen Alternative zum autologen Transplantat. Die etablierte Prozesskette zeigte eine gute Praktikabilität und Wirtschaftlichkeit im Umgang mit DCPD / DCPA. Alle Modelldefekte konnten mit PSI rekonstruiert werden. Diese zeigten eine gute Passung in der Defektregion und eine gute äußere Kontur. Für eine tatsächliche klinische Anwendung 3D-pulvergedruckter CaPC-Implantate wird eine Validierung und schließlich Zertifizierung der gesamten Prozesskette einschließlich der Herstellung der Reaktanden erforderlich. Um das Verhalten der Implantate im menschlichen Organismus bewerten zu können, wäre zunächst der Einsatz als temporäres Implantat (z. B. als Platzhalter nach Unterkieferresektion vor definitiver autologer Rekonstruktion) als sinnvolle Erstanwendung denkbar. / The aim of this dissertation was to establish a process chain for the production of anatomical patient-specific implants of dicalcium phosphate in a 3D powder printing process. The pilot project was designed to evaluate the practicability and accuracy of this process chain. A human cadaver skull was dissected with several bone defects and then reconstructed according to its CT data using a self-programmed mirror-imaging software. The software was able to construct virtual implants which were processed with a 3D powder printer to obtain patient-specific implants. The success of the process chain was evaluated by the coverage of the skull defects in the model. Furthermore, dicalcium phosphates were tested for their suitability as an implant material regarding mechanical and thermal properties. The process chain turned out to be feasible. All defects were reconstructed with high precision and good anatomical contour. However, due to the low stability of the materials, the implants are only suitable for non-load-bearing defects.
2

Establishing and Improving Methods for Biofabrication / Etablierung und Verbesserung von Methoden für die Biofabrikation

Jüngst, Tomasz January 2019 (has links) (PDF)
Die Biofabrikation ist ein junges und sehr dynamisches Forschungsgebiet mit viel Potential. Dieses Potential spiegelt sich unter anderem in den ambitionierten Zielen wieder, die man sich hier gesetzt hat. Wissenschaftler in diesem Gebiet wollen eines Tages beispielsweise funktionale menschliche Gewebe nachbilden, die aus patienteneigenen Zellen bestehen. Diese Gewebe sollen entweder für die Testung neuer Arzneimittel und Therapien oder sogar als Implantate einsetzt werden. Der Schlüssel zum Erfolg soll hier die Verwendung automatisierter Prozesse in Verbindung mit innovativen Materialien sein, die es ermöglichen, die Hierarchie und Funktion des zu ersetzenden natürlichen Gewebes nachbilden. Obwohl in den letzten Jahren große Fortschritte gemacht worden sind, gibt es immer noch Hürden, die überwunden werden müssen. Ziel dieser Arbeit war es deshalb, die derzeit eingeschränkte Auswahl kompatibler Materialien für die Biofabrikation zu erweitern und bereits etablierte Verfahren wie den extrusionsbasierten Biodruck noch besser verstehen zu lernen. Auch neue Verfahren, wie etwa das Melt Electrospinning Writing (MEW) sollten etabliert werden. In Kapitel 3 dieser Arbeit wurde das MEW dazu verwendet, tubuläre Strukturen zu fertigen, die sich aus Polymerfasern mit einem durchschnittlichen Durchmesser von nur etwa 12 μm zusammensetzen. Die mit Hilfe von Druckluft in Verbindung mit einer hohen elektrischen Spannung aus einer Nadelspitze austretende Polymerschmelze wurde hierbei auf zylinderförmigen Kollektoren mit Durchmessern zwischen 0.5 und 4.8mm gesammelt. Auf diese Weise wurden röhrenförmige Faserkonstrukte generiert. Das Hauptaugenmerk lag auf dem Einfluss des Durchmessers, der Rotations- und Translationsbewegung des Kollektors auf die Morphologie der Faserkonstrukte. Hierzu wurden die Fasern erst auf unbewegten Kollektoren mit unterschiedlichen Durchmessern gesammelt und die entstehenden Muster analysiert. Es zeigte sich, dass das Fasermuster mit zunehmendem Durchmesser des Kollektors mehr den symmetrischen Konstrukten mit runder Grundfläche glich, die auch von flachen Kollektoren bekannt sind. Je kleiner der Kollektordurchmesser wurde, desto ovaler wurde die Grundfläche der Muster, was den Einfluss der Krümmung deutlich machte. In weiteren Experimenten wurden die zylindrischen Kollektoren mit Geschwindigkeiten von 4,2 bis 42 Umdrehungen pro Minute um ihre Längsachse gedreht. Die von flachen Kollektoren bekannten Übergänge der Fasermorphologie konnten auch für runde Kollektoren bestätigt werden. So änderte sich die Morphologie mit zunehmender Geschwindigkeit der Oberfläche von einer achterförmigen Gestalt über eine sinusförmige Ausrichtung der Fasern hin zu einer geraden Linie. Der Einfluss des Kollektordurchmessers wurde auch hier deutlich, da sich etwa die Amplitude der bei Rotationsgeschwindigkeiten im Bereich sinusförmiger Ausrichtung abgelegten Fasern mit abnehmendem Radius erhöhte. Im nächsten Schritt wurde neben der Rotation der Kollektoren auch eine Translation induziert. Durch geeignete Kombination von Rotation und Translation konnten Konstrukte mit definiertem Wickelwinkel hergestellt werden. Es zeigte sich, dass die Wiedergabe des vorher kalkulierten Winkels unter Verwendung von Oberflächengeschwindigkeiten, die nahe am Übergang zur geraden Faserausrichtung waren, am besten war. Im Rahmen dieser Arbeit konnten Winkel zwischen 5 und 60° mit hoher Präzision wiedergegeben werden. Im Falle von sich wiederholenden Mustern konnte auch in Bezug auf die Stapelbarkeit der Fasern aufeinander eine hohe Präzision erreicht werden. Kapitel 4 dieser Arbeit befasste sich mit dem extrusionsbasierten 3D-Druck. Das etabliere Verfahren wurde auf eine bisher wenig untersuchte Materialzusammensetzung von Nanopartikeln-beladenen Hydrogeltinten ausgeweitet. Die Tinte bestand aus einer Kombination von funktionalisierten Polyglyzidolen und einer unmodifizierten langkettingen Hyaluronsäure. Dieser wurden mesoporöse Silika-Nanopartikel mit unterschiedlicher Ladung zugesetzt und deren Freisetzung aus gedruckten Konstrukten mit einstellbarer Geometrien untersucht. Da die Hyaluronsäure selbst negativ geladen ist, wurde erwartet und auch gezeigt, dass aminofunktionalisierte Partikel mit positiver Ladung langsamer freigesetzt werden als carboxylfunktionalisierte Partikel mit negativer Ladung. Interessanterweise änderten die Partikel nicht die rheologischen Eigenschaften der Tinte und es konnten Hydrogele, die mit positiv geladenen Partikeln beladen waren, bei den gleichen Druckparametern verdruckt werden, wie Hydrogele, die mit negativ geladenen Partikeln beladen waren. Die guten Druckeigenschaften der Tinten ermöglichten die präzise Fertigung von Konstrukten mit einer Größe von 12x12x3mm^3, also von Konstrukten mit bis zu 16 aufeinanderfolgenden Lagen. Die Strangdurchmesser betrugen hierbei 627±31μm und die Verteilung der Partikel innerhalb der Stränge war sehr homogen. Zudem konnten auch Strukturen gedruckt werden, bei denen beide Tintenarten, mit positiven und mit negativen Partikeln beladene Hydrogele, in einem Konstrukt kombiniert wurden. Hierbei zeigte sich, dass die Freisetzung der Partikel, die über 6 Wochen hinweg untersucht wurde, auch stark von der Geometrie der zwei-Komponenten-Konstrukte abhing. Insbesondere die Auswirkung des direkten Kontakts zwischen den Komponenten innerhalb eines Konstruktes war hier sehr deutlich. Wurden die Stränge über Kreuz aufeinander abgelegt und hatten direkten Kontakt an den Kreuzungspunkten, konnte beobachtet werden, dass die positiv geladenen Partikel aus ihrem System in das mit den negativ geladenen Partikeln wanderten. Wurden die Stränge ohne direkten Kontakt parallel nebeneinander abgelegt, wurden die positiv geladenen Partikel in umgebendes Medium freigesetzt, konnten aber selbst nach 6 Wochen nicht in den Strängen mit den negativ geladenen Partikeln nachgewiesen werden. Dies verdeutlicht, dass Geometrie und Ladung der Partikel einen Einfluss auf die Freisetzung der Partikel hatten und sich die Freisetzung der Partikel durch eine geschickte Kombination beider Parameter steuern lässt. In Kapitel 5 dieser Arbeit wurde eine neue Materialklasse als Biotinte für den extrusionsbasierten Biodruck untersucht. Bei dem Material handelte es sich um Hydrogele auf Basis rekombinanter Spinnenseidenproteine. Diese konnten ab einer Proteinkonzentration von 3 %Gew./Vol. ohne die Verwendung von Verdickungsmittel oder anderen Additiven und auch ohne eine nachträgliche Vernetzung verdruckt werden. Sowohl Hydrogele auf Basis des rekombinanten Proteins eADF4(C16) als auch eine mit einer RGD-Sequenz versehene Modifikation (eADF4(C16)-RGD) konnten mit einer hohen Formtreue verdruckt werden. Die RGD-Sequenz zeigte einen positiven Effekt auf das Anhaften von humanen Fibroblasten, die auf gedruckte Konstrukte ausgesät wurden. Zudem konnten mit Hilfe der Hydrogele auch zellbeladene Konstrukte gefertigt werden. Hierzu wurden die Hydrogele mit einer Zellsuspension so vermengt, dass eine finale Konzentration von 1,2 Millionen Zellen/ml erreicht wurde. Die beladenen Gele wurden verdruckt und es konnte eine Überlebensrate von 70,1±7,6% nachgewiesen werden. Das in diesem Kapitel etablierte Materialsystem ermöglichte zum ersten Mal das Verdrucken lebender Zellen in einer neuen Klasse von Tinten, die weder die Beimengung von Verdickungsmittel noch einen zusätzlichen Nachhärtungsschritt für die Herstellung zellbeladener stabiler Konstrukte benötigt. / Biofabrication is an advancing new research field that might, one day, lead to complex products like tissue replacements or tissue analogues for drug testing. Although great progress was made during the last years, there are still major hurdles like new types of materials and advanced processing techniques. The main focus of this thesis was to help overcoming this hurdles by challenging and improving existing fabrication processes like extrusion-based bioprinting but also by developing new techniques. Furthermore, this thesis assisted in designing and processing materials from novel building blocks like recombinant spider silk proteins or inks loaded with charged nanoparticles. A novel 3D printing technique called Melt Electrospinning Writing (MEW) was used in Chapter 3 to create tubular constructs from thin polymer fibers (roughly 12 μm in diameter) by collecting the fibers onto rotating and translating cylinders. The main focus was put on the influence of the collector diameter and its rotation and translation on the morphology of the constructs generated by this approach. In a first step, the collector was not moving and the pattern generated by these settings was analyzed. It could be shown that the diameter of the stationary collectors had a big impact on the morphology of the constructs. The bigger the diameter of the mandrel (smallest collector diameters 0.5 mm, biggest 4.8 mm) got, the more the shape of the generated footprint converged into a circular one known from flat collectors. In a second set of experiments the mandrels were only rotated. Increasing the rotational velocity from 4.2 to 42.0 rpm transformed the morphology of the constructs from a figure-of-eight pattern to a sinusoidal and ultimately to a straight fiber morphology. It was possible to prove that the transformation of the pattern was comparable to what was known from increasing the speed using flat collectors and that at a critical speed, the so called critical translation speed, straight fibers would appear that were precisely stacking on top of each other. By combining rotation and translation of the mandrel, it was possible to print tubular constructs with defined winding angles. Using collections speeds close to the critical translation speed enabled higher control of fiber positioning and it was possible to generate precisely stacked constructs with winding angles between 5 and 60°. In Chapter 4 a different approach was followed. It was based on extrusion-based bioprinting in combination with a hydrogel ink system. The ink was loaded with nanoparticles and the nanoparticle release was analyzed. In other words, two systems, a printable polyglycidol/hyaluronic acid ink and mesoporous silica nanoparticles (MSN), were combined to analyze charge driven release mechanism that could be fine-tuned using bioprinting. Thorough rheological evaluations proved that the charged nanoparticles, both negatively charged MSN-COOH and positively charged MSN-NH2, did not alter the shear thinning properties of the ink that revealed a negative base charge due to hyaluronic acid as one of its main components. Furthermore, it could be shown that the particles did also not have a negative effect on the recovery properties of the material after exposure to high shear. During printing, the observations made via rheological testing were supported by the fact that all materials could be printed at the same settings of the bioprinter. Using theses inks, it was possible to make constructs as big as 12x12x3 mm3 composed of 16 layers. The fiber diameters produced were about 627±31 μm and two-component constructs could be realized utilizing the two hydrogel print heads of the printer to fabricate one hybrid construct. The particle distribution within those constructs was homogeneous, both from a microscopic and a macroscopic point of view. Particle release from printed constructs was tracked over 6 weeks and revealed that the print geometry had an influence on the particle release. Printed in a geometry with direct contact between the strands containing different MSN, the positively charged particles quickly migrated into the strand previously containing only negatively charged MSN-COOH. The MSN-COOH seemed to be rather released into the surrounding liquid and also after 6 weeks no MSN-COOH signal could be detected in the strand previously only containing MSN-NH2. In case of a geometry without direct contact between the strands, the migration of the positively charged nanoparticles into the MSN-COOH containing strand was strongly delayed. This proved that the architecture of the printed construct can be used to fine-tune the particle release from nanoparticle containing printable hydrogel ink systems. Chapter 5 discusses an approach using hydrogel inks based on recombinant spider silk proteins processed via extrusion-based bioprinting. The ink could be applied for printing at protein concentrations of 3 % w/v without the addition of thickeners or any post process crosslinking. Both, the recombinant protein eADF4(C16) and a modification introducing a RGD-sequence to the protein (eADF4(C16)-RGD), could be printed revealing a very good print fidelity. The RGD modification had positive effect on the adhesion of cells seeded onto printed constructs. Furthermore, human fibroblasts encapsulated in the ink at concentrations of 1.2 million cells per mL did not alter the print fidelity and did not interfere with the crosslinking mechanism of the ink. This enabled printing cell laden constructs with a cell survival rate of 70.1±7.6 %. Although the cell survival rate needs to be improved in further trials, the approach shown is one of the first leading towards the shift of the window of biofabrication because it is based on a new material that does not need potentially harmful post-process crosslinking and allows the direct encapsulation of cells staying viable throughout the print process.
3

Computergestütztes Auffinden obliterierter Wurzelkanäle mit Hilfe der Planungssoftware SicatEndo und CDX – eine In-vitro-Vergleichsstudie / Computer based access cavity preparation in teeth with pulp canal obliteration by using the software sicat endo and cdx - a comparative in vitro study

Reich, Sebastian January 2021 (has links) (PDF)
Ziel der Untersuchung: Verglichen wurden die räumlichen Abweichungen der Bohrpfade nach virtueller Planung von Schablonen geführten Trepanationen mit Hilfe der Softwaresysteme SicatEndo (SE) und coDiagnostiX (CDX) und der benötigte Arbeitsaufwand. Material und Methode: Basierend auf µCT-Datensätzen von humanen obliterierten Frontzähnen wurden identische Kunststoffzähne und acht Zahnmodelle (4 Ober-, 4 Unterkiefer) hergestellt. Es wurde jeweils ein DVT und ein Oberflächenscan angefertigt. Diese Datensätze (DICOM; STL) wurden in die Softwaresysteme importiert und fusioniert. Anschließend wurden die Bohrpfade für je 16 Probenzähne pro Software geplant. Mit Hilfe der erstellten Schablonen wurden alle Trepanationen an den im Phantomkopf fixierten Modellen von einem Behandler durchgeführt. Nach Erschließung des apikalen Wurzelkanalanteils wurde ein DVT angefertigt und mit dem präoperativen DVT überlagert. Die räumliche drei-dimensionale (3D) Abweichung zwischen virtuell geplantem und tatsächlichem Bohrpfad wurde über die Vektorlänge bestimmt und der Arbeitsaufwand anhand der Planungszeit und der Anzahl der Mausklicks pro Kiefer erfasst. Ergebnisse: Für die Trepanationen mit SE zeigten sich signifikant geringe Abweichungen an der Bohrerspitze vestibulär-oral [CDX 0,54mm ± 0,32mm; SE 0,12mm ± 0,11mm; p < 0.05], 3D [CDX 0,74mm ± 0,26 mm; SE 0,35mm ± 0,17mm; p < 0.05] und hinsichtlich des Winkels [CDX 1,57° ± 0,76°; SE 0,68° ± 0,41°; p < 0.05] als mit CDX. Für CDX war der Planungsaufwand signifikant geringer als für SE hinsichtlich Planungszeit [CDX Ø 10min 50sec; SE Ø 20min 28sec] und hinsichtlich der Anzahl der Klicks pro Kiefer [CDX Ø 107; SE Ø 341]. Zusammenfassung: Beide Planungssysteme ermöglichen ausreichend präzise Schablonen geführte Bohrungen zur Erschließung apikaler Wurzelkanalanteile. / Aim: To compare the accuracy and effort of digital workflow for guided endodontic access procedures using two different software applications in 3D-printed teeth modeled to simulate pulp canal obliteration in vitro. Materials and methods: 32 3D-printed incisors with simulated PCO were fabricated and mounted, four each on maxillary and mandibular study arches. Cone beam computed tomography (CBCT) and 3D surface scans were matched and used to virtually plan and prepare GEA by one operator using two different methods: 1) coDiagnostiX (CDX) with 3D-printed templates, and 2) SicatEndo (SE) with subtractive CAD/CAM-manufactured templates. Postoperative CBCT and virtual planning data were superimposed for analysis. Accuracy was assessed by measuring the discrepancies between planned and prepared cavities at the tip of the bur (three spatial dimensions, 3D vector, angle). Virtual planning effort was defined as the time and number of computer clicks. A 95% confidence interval (CI) was computed for each sample . Results: SE successfully located root canals for GEA in 16/16 cases (100%) and CDX in 15/16 cases (94%). SE resulted in less mean deviation at the tip of the bur with regard to distance in the labial-oral direction (0.12 mm), 3D vector (0.35 mm), and angle (0.68 degrees) compared with CDX (0.54 mm, 0.74 mm, 1.57 degrees, respectively; P < 0.001). CDX required less mean planning time and effort for each four-tooth arch (10 min 50 s, 107 clicks) than SE (20 min 28 s, 341 clicks; P < 0.05). Conclusions: Both methods enabled rapid drill path planning, a predictable GEA procedure, and the reliable location of root canals in teeth with PCO without perforation.
4

Rapid-Prototyping hydraulisch härtender Calcium- und Magnesiumphosphatzemente mit lokaler Wirkstoffmodifikation / Rapid-prototyping of hydraulic calcium- and magnesium phosphate cements with local drug modification

Vorndran, Elke January 2011 (has links) (PDF)
Ziel dieser Arbeit war die Herstellung individuell formbarer Strukturen mittels des 3D-Pulverdrucks auf Basis von bei Raumtemperatur hydraulisch abbindenden Knochenzementpulvern. Neben der Entwicklung neuartiger Zementformulierungen auf Basis von Magnesiumphosphaten war vor allem die gleichzeitige Ausstattung der Werkstoffe mit temperaturlabilen und bioaktiven Verbindungen ein wichtiger Entwicklungsschritt. Die Lokalisation der Wirkstoffe korreliert dabei mit entsprechenden Farbinformationen im Design der Konstrukte, die durch einen Mehrfarbendrucker physikalisch abgebildet werden. Das auf Calciumphosphat basierende System hat den Nachteil, dass die Abbindereaktion bei stark sauren pH-Werten abläuft, was negative Auswirkungen auf die gleichzeitige Ausstattung mit sensitiven Wirkstoffen hat. Zur Lösung dieser Problematik wurde ein neues Knochenzementpulver auf Magnesiumphosphatbasis entwickelt, welches unter neutralen pH-Bedingungen mit ammoniumhaltigem Binder zu dem Mineral Struvit abbindet. Das Zementpulver aus Trimagnesiumphosphat wurde bezüglich der pulvertechnologischen Eigenschaften, wie Partikelgröße, Partikelgrößenverteilung, Glättungseigenschaften und Schüttdichte sowie hinsichtlich des Abbindeverhaltens charakterisiert und für den Druckprozess optimiert. Die hohe Strukturgenauigkeit ermöglichte die Darstellung von makroporösen Strukturen mit einem minimalen Porendurchmesser von ca. 200 µm. Gute mechanische Kennwerte der gedruckten Strukturen, sowie eine hohe Umsetzungsrate zur gewünschten Phase Struvit wurden durch eine Nachhärtung in Ammoniumphosphatlösung erhalten. Die Druckfestigkeit betrug > 20 MPa und der Phasenanteil von Struvit konnte auf insgesamt 54 % gesteigert werden. Die Darstellung von wirkstoffmodifizierten Calciumphosphat- und Magnesiumphosphatstrukturen durch Verwendung eines Mehrfarbendruckers wurde beginnend vom Design der Strukturen bis hin zur experimentellen Bestimmung der Korrelation von Farbinformation und Binderapplikation etabliert. Zur Sicherstellung einer hohen Druckqualität und der Ortsständigkeit gedruckter Wirkstoffe erwies sich eine zusätzliche Modifikation des Tricalciumphosphatpulvers mit quellfähigen Polymeren (Hydroxypropylmethyl-cellulose (HPMC) bzw. Chitosan) als erfolgreich. Eine maximale Auflösung von ca. 400 µm konnte für eine HPMC/Chitosan/Calciumphosphat-Variante erreicht werden, während das hochreaktive Magnesiumphosphat/Magnesiumoxid-System eine Auflösung von 480 µm aufwies. Die Ortsständigkeit eingebrachter Lösungen war Voraussetzung für die Steuerung der Freisetzungskinetik. Das Freisetzungsverhalten in vitro wurde in Abhängigkeit von der Wirkstofflokalisation (homogen, Depot, Gradient) innerhalb der Matrix und unter Einbringung zusätzlicher polymerer Diffusionsbarrieren für den Wirkstoff Vancomycin untersucht. Dabei zeigte sich, dass die Modifikation der Matrices mit Polymeren zu einer verzögerten Freisetzung führte. Die lokale Wirkstoffmodifikation der Matrices in Form eines Depots oder Gradienten hatte Einfluss auf die Freisetzungskinetik, wobei eine lineare Freisetzung mit der Zeit (Kinetik 0. Ordnung) erreicht werden konnte. Die applizierten Wirkstoffe umfassten sowohl niedermolekulare Verbindungen, wie etwa das Antibiotikum Vancomycin oder das Polysaccharid Heparin, als auch proteinbasierte Faktoren wie den Knochenwachstumsfaktor rhBMP-2. Beurteilt wurde die pharmakologische Wirksamkeit der Verbindungen nach dem Druck, sowie nach der Freisetzung aus einer Calciumphosphatmatrix für den Wirkstoff Vancomycin. Es konnte belegt werden, dass die biologische Aktivität nach dem Druckprozess zu über 80 % erhalten blieb. Limitierend war der stark saure pH-Wert bei bruschitbasierten Systemen, der zu einer Inaktivierung des Proteins führte. Diesem Problem könnte durch die Nutzung des neutral abbindenden Magnesiumphosphatsystems entgegengewirkt werden. Abschließend erfolgten eine mikrostrukturelle Charakterisierung der Calciumphosphat- und Magnesiumphosphatmatrices mittels µ-CT-Analyse und Heliumpyknometrie, sowie eine quantitative Phasenanalyse nach Rietveld. Experimentell konnte nachgewiesen werden, dass mit Hilfe des 3D-Pulverdruck die Darstellung von Makroporen > 200 µm möglich ist. Die Analyse der Phasenzusammensetzung ergab, dass die Umsetzungsrate von Tricalciumphosphat und Trimagnesiumphosphat zu den gewünschten Phasen Bruschit und Struvit infolge des Nachhärtungsprozesses signifikant gesteigert werden konnte. Im Zuge dessen nahm die Porosität der gedruckten Matrices der Phase Struvit von 58 % auf 26 % und der Phase Bruschit von 47 % auf 38 % ab. / Aim of this study was the room temperature fabrication of individually formed structures via 3D-powder printing based on hydraulic bone cements. In addition to the development of a novel cement formulation composed of magnesium phosphate, the simultaneous modification of matrices during the printing process with temperature sensitive and bioactive drugs was an important part of the work. The drug localization within the matrices is hereby correlated with an analogous colour design of the structures, which is physically reproduced by the multi-colour-printer. The calcium phosphate based system has the disadvantage of a strongly acidic setting reaction, which has negative effects on the simultaneous modification with sensitive bioactive agents. To solve this problem a novel bone cement formulation based on magnesium phosphate was established. This cement reacts with ammonium based binder solution within seconds to form the mineral struvite at neutral pH. The technological properties of the of trimagnesium phosphate cement powder, including particle size, particle size distribution, spreadability, powder density, and the setting behaviour, were characterized and optimized for the printing process. The high structural accuracy enabled the production of macroporous structures with a minimal pore diameter of approximately 200 µm. Proper mechanical characteristics of the printed structures as well as a high degree of conversion to the struvite phase were achieved by post-hardening in ammonium phosphate solution. The compressive strength could be increased to more than 20 MPa and the phase fraction of struvite could be increased to a maximum value of a total of 54 %. The fabrication of drug loaded calcium phosphate and magnesium phosphate scaffolds using a multi-colour-printer was established, beginning with the structure design and following the experimental verification of the correlation between the colour information and the applied binder. To guarantee a high accuracy of printing and the localization of the printed drugs, a supplemental modification of the tricalcium phosphate powder with swellable polymers (hydroxypropylmethylcellulose (HPMC) or chitosan) was successful. A maximum resolution of about 400 µm was achieved by an HPMC/chitosan/calcium phosphate composition, whereas the highly reactive magnesium phosphate/magnesium oxide system showed a resolution of about 480 µm. The localization of the applied solutions was a prerequisite to control the release kinetics of the drugs. The release kinetic of vancomycin was investigated in vitro depending on the drug localization (homogeneous, depot, gradient-like) within the matrix and by adding additional polymeric diffusion barriers. It could be shown that the polymeric modification of the matrices resulted in a delayed drug release. By discrete and depot-like or graded drug distributions within the matrices the release kinetic could be controlled, achieving a linear release with time (zero order release). The administered agents involved both low molecular compounds like the antibiotic vancomycin or the polysaccharide heparin and protein based factors like bone morphogenic factor rhBMP-2. Evaluation of pharmacological activity of the agents after printing as well as after release of vancomycin from a calcium phosphate matrix was determined, indicating that the bulk biological activity of more than 80 % was retained during the printing process. The limiting factor of the brushite based system was the strong acidic pH, which resulted in an inactivation of protein-based bioactives. This problem may be solved by using neutrally setting magnesium phosphate systems. Finally a microstructural characterization of calcium phosphate and magnesium phosphate matrices by µ-CT analysis and helium pycnometry as well as a quantitative phase analysis by Rietveld was performed. It was demonstrated, that 3D-printing allows the manufacturing of macro pores > 200 µm. The analysis of phase composition showed a significant increase of the degree of conversion from tricalcium phosphate or trimagnesium phosphate to the phases brushite or struvite due to the post hardening process. Hence the porosity of the printed matrices decreased from 58 % to 26 % for struvite and from 47 % to 38 % for brushite.
5

Thiol-ene Cross-linked Poly(glycidol) / Hyaluronic Acid Based Hydrogels for 3D Bioprinting / Thilo-En vernetzte Hydrogele basierend auf Poly(glyzidolen) und Hyaluronsäure für das 3D-Biodrucken

Schäfer [geb. Stichler], Simone January 2019 (has links) (PDF)
The aim of the work was the development of thiol-ene cross-linked hydrogels based on functionalized poly(glycidol)s (PG) and hyaluronic acid (HA) for extrusion based 3D bioprinting. Additionally, the functionalization of the synthesized PG with peptides and the suitability of these polymers for physically cross-linked gels were investigated, in a proof of principle study in order to demonstrate the versatile use of PG polymers in hydrogel development. First, the precursor polymers of the different hydrogel systems were synthesized. For thiol-ene cross-linked hydogels, linear allyl-functionalized PG (P(AGE-co-G)) and three different thiol-(SH-)functionalized polymers, ester-containing PG-SH (PG SHec), ester-free PG-SH (PG-SHef) and HA-SH were synthesized and analysed, The degree of functionalization of these polymers was adjustable. For physically cross-linked hydrogels, peptide-functionalized PG (P(peptide-co-G)), was synthesized through polymer analogue thiol-ene modification of P(AGE-co-G). Subsequently, thiol-ene cross-linked hydrogels were prepared with the synthesized thiol- and allyl-functionalized polymers. Depending on the origin of the used polymers, two different systems were obtained: on the one hand synthetic hydrogels consisting of PG-SHec/ef and P(AGE-co-G) and on the other hand hybrid gels, consisting of HA-SH and P(AGE-co-G). In synthetic gels, the degradability of the gels was determined by the applied PG-SH. The use of PG-SHec resulted in hydrolytically degradable hydrogels, whereas the cross-linking with PG-SHef resulted in non-degradable gels. The physical properties of these different hydrogel systems were determined by swelling, mechanical and diffusion studies and subsequently compared among each other. In swelling studies the differences of degradable and non-degradable synthetic hydrogels as well as the differences of synthetic compared to hybrid hydrogels were demonstrated. Next, the stiffness and the swelling ratios (SR) of the established hydrogel systems were examined in dependency of different parameters, such as incubation time, polymer concentration and UV irradiation. In general, these measurements revealed the same trends for synthetic and hybrid hydrogels: an increased polymer concentration as well as prolonged UV irradiation led to an increased network density. Moreover, it was demonstrated that the incorporation of additional non-bound HMW HA hampered the hydrogel cross-linking resulting in gels with decreased stiffness and increased SR. This effect was strongly dependent on the amount of additional HMW HA. The diffusion of different molecular weight fluorescein isothiocyanate-dextran (FITC-dextran) through hybrid hydrogels (with/without HMW HA) gave information about the mesh size of these gels. The smallest FITC-dextran (4 kDa) completely diffused through both hydrogel systems within the first week, whereas only 55 % of 40 kDa and 5-10 % HMW FITC-dextrans (500 kDa and 2 MDa) could diffuse through the networks. The applicability of synthetic and hybrid hydrogels for cartilage regeneration purpose was investigated through by biological examinations. It was proven that both gels support the survival of embedded human mesenchymal stromal cells (hMSCs) (21/28 d in vitro culture), however, the chondrogenic differentiation was significantly improved in hybrid hydrogels compared to synthetic gels. The addition of non-bound HMW HA resulted in a slightly less distinct chondrogenesis. Lastly the printability of the established hydrogel systems was examined. Therefore, the viscoelastic properties of the hydrogel solutions were adjusted by incorporation of non-bound HMW HA. Both systems could be successfully printed with high resolution and high shape fidelity. The introduction of the double printing approach with reinforcing PCL allowed printing of hydrogel solutions with lower viscosities. As a consequence, the amount of additional HMW HA necessary for printing could be reduced allowing successful printing of hybrid hydrogel solutions with embedded cells. It was demonstrated that the integrated cells survived the printing process with high viability measured after 21 d. Moreover, by this reinforcing technique, robust hydrogel-containing constructs were fabricated. In addition to thiol-ene cross-linked hydrogels, hydrogel cross-linking via ionic interactions was investigated with a hybrid hydrogel based on HMW HA and peptide-functionalized PG. Rheological measurements revealed an increase in the viscosity of a 2 wt.% HMW HA solution by the addition of peptide-functionalized PG. The increase in viscosity could be attributed to the ionic interactions between the positively charge PG and the negatively charge HMW HA. In conclusion, throughout this thesis thiol-ene chemistry and PG were introduced as promising cross-linking reaction and polymer precursor for the field of biofabrication. Furthermore, the differences of hybrid and synthetic hydrogels as well as chemically and physically cross-linked hydrogels were demonstrated. Moreover, the double printing approach was demonstrated to be a promising tool for the fabrication of robust hydrogel-containing constructs. It opens the possibility of printing hydrogels that were not printable yet, due to too low viscosities. / Ziel der Arbeit war die Entwicklung von Thiol-En-vernetzten Hydrogelen basierend auf funktionalisierten Poly(glyzidolen) (PG) und Hyaluronsäure (HA) für das extrusionsbasierte 3D-Biodrucken. Um die vielseitigen Anwendungsmöglichkeiten von PG-Polymeren für die Hydrogelentwicklung zu zeigen, wurde darüber hinaus, in einer Proof-of-Principle-Studie, PG mit Peptiden funktionalisiert und die Eignung dieser Polymere für die Herstellung von physikalisch vernetzten Gelen untersucht. Zunächst wurden die Vorläuferpolymere für die verschiedenen Hydrogelsysteme synthetisiert. Für die Thiol-En-vernetzten Hydrogele wurde lineares Allyl-funktionalisiertes PG (P(AGE-co-G)) und drei verschiedene Thiol-(SH )funktionalisierte Polymere, Ester haltiges PG-SH (PG-SHec), Ester freies PG SH (PG-SHef) und HA-SH synthetisiert und analysiert. Dabei war der Funktionalisierungsgrad dieser Polymere einstellbar. Für physikalisch vernetzte Hydrogele wurde Peptid-funktionalisierte PGs (P(Peptid co-G)) mittels polymeranaloger Thiol-En-Modifikation von P(AGE-co-G) synthetisiert. Anschließend wurden Thiol-En-vernetzte Hydrogele auf Basis der synthetisierten Thiol- und Allyl-funktionalisierten Polymeren hergestellt. Je nach Ursprung der verwendeten Polymere wurden zwei verschiedene Systeme erhalten: einerseits synthetische Hydrogele bestehend aus PG-SHec/ef und P(AGE-co-G) und andererseits hybride Gele, bestehend aus HA-SH und P(AGE-co-G). Bei den synthetischen Gelen wurde die Abbaubarkeit der Gele durch das verwendete PG-SH bestimmt. Die Verwendung von PG-SHec resultierte in hydrolytisch abbaubaren Hydrogelen, während die Vernetzung mit PG-SHef zu nicht abbaubaren Gelen führte. Die physikalischen Eigenschaften der verschiedenen Hydrogelsysteme wurden mittels Quell-, mechanischen und Diffusionsexperimenten bestimmt und anschließend miteinander verglichen. Die Quellungsstudien zeigten die Unterschiede von abbaubaren und nicht abbaubaren synthetischen Hydrogelen, sowie die Unterschiede von synthetischen gegenüber hybriden Hydrogelen. Als nächstes wurden die Steifigkeit und das Quellverhältnis (SR) der etablierten Hydrogelsysteme in Abhängigkeit von verschiedenen Parametern wie Inkubationszeit, Polymerkonzentration und UV-Bestrahlung untersucht. Im Allgemeinen zeigten diese Messungen für synthetische und hybride Hydrogele die gleichen Trends: eine erhöhte Polymerkonzentration sowie eine verlängerte UV-Bestrahlung führten zu einer erhöhten Netzwerkdichte. Darüber hinaus wurde gezeigt, dass das Einbringen zusätzlicher, nicht gebundener HMW HA die Hydrogelvernetzung behinderte, was zu Gelen mit verringerter Steifigkeit und erhöhtem SR führte. Dieser Effekt war stark abhängig von der Menge an zusätzlich eingebrachter HMW HA. Die Diffusion von Fluorescein-Isothiocyanat-Dextran (FITC-Dextran) mit unterschiedlichem Molekulargewichten durch hybride Hydrogele (mit/ohne HMW HA) lieferte Informationen über die Maschengröße dieser Gele. Das kleinste FITC-Dextran (4 kDa) diffundierte innerhalb der ersten Woche vollständig durch beide Hydrogelsysteme, während nur 55 % der 40 kDa und 5-10 % HMW FITC-Dextrane (500 kDa und 2 MDa) durch die Netzwerke diffundieren konnten. Die Anwendbarkeit von synthetischen und hybriden Hydrogelen für Knorpelregenerationszwecke wurde durch biologische Experimente untersucht. Es wurde bewiesen, dass beide Gele das Überleben von eingebetteten humanen mesenchymalen Stromazellen (hMSCs) unterstützen (21/28 d in vitro Kultur), jedoch war die chondrogene Differenzierung in hybriden Hydrogelen im Vergleich zu synthetischen Gelen signifikant verbessert. Die Zugabe von nicht gebundenem HMW HA führte zu einer etwas weniger ausgeprägten Chondrogenese. Zuletzt wurde die Druckbarkeit der etablierten Hydrogelsysteme untersucht. Dafür wurden die viskoelastischen Eigenschaften der Hydrogellösungen durch das Einbringen von nicht gebundener HMW HA eingestellt. Beide Systeme konnten erfolgreich mit hoher Auflösung und hoher Formgenauigkeit gedruckt werden. Die Einführung des Doppeldruck-Konzeptes mit verstärkendem PCL ermöglichte das Drucken von Hydrogellösungen mit niedrigeren Viskositäten. Infolgedessen konnte die für den Druck notwendige Menge an HMW HA reduziert und hybride Hydrogellösungen mit eingebetteten Zellen erfolgreich gedruckt werden. Es wurde gezeigt, dass die integrierten Zellen den Druckprozess mit hoher Vitalität überlebten (gemessen nach 21 d). Darüber hinaus wurden mit dieser Verstärkungstechnik robuste Hydrogel-enthaltende Konstrukte hergestellt. Zusätzlich zu den Thiol-En-vernetzten Hydrogelen wurde die Hydrogelvernetzung mittels elektrostatischen Wechselwirkungen mit einem hybriden Gel auf der Basis von HMW HA und Peptid-funktionalisiertem PG untersucht. Rheologische Messungen ergaben eine Erhöhung der Viskosität einer 2 wt.% HMW HA Lösungen durch die Zugabe von Peptid-funktionalisiertem PG. Der Viskositätsanstieg konnte auf die elektrostatischen Wechselwirkungen zwischen dem positiv geladenen PG und der negativ geladenen HMW HA zurückgeführt werden. Zusammenfassend wurde in dieser Arbeit die Thiol-En-Chemie und PG als vielversprechende Vernetzungsreaktion bzw. Polymervorstufe für die Biofabrikation eingeführt. Des Weiteren wurden die Unterschiede von hybriden und synthetischen Hydrogelen sowie von chemisch und physikalisch vernetzten Hydrogelen aufgezeigt. Darüber hinaus wurde gezeigt, dass das Doppeldruck-Konzept eine vielversprechende Methode für die Herstellung von robusten Hydrogel-enthaltenden Konstrukten ist. Es eröffnet die Möglichkeit, Hydrogele zu drucken, die aufgrund zu geringer Viskositäten bis jetzt nicht druckbar waren.
6

3D-Druck mikrofluidischer Systeme mittels Stereolithografie / 3D printing of microfluidic systems by stereolithography

Link, Yasmin January 2020 (has links) (PDF)
Der 3D-Druck ist ein elementarer Bestandteil der Biofabrikation. Beispielsweise wird mittels Biotinten und einem geeigneten 3D-Druckverfahren Schicht für Schicht eine Geometrie aufgebaut. Durch die Gestaltung von mikrofluidischen Druckköpfen wird eine Möglichkeit geschaffen multiple Materialansätze im Druckkopf zu vermischen und so in einem bestimmten Mischungsverhältnis zu drucken. Mit dem DLP-SLA-Drucker Vida HD Crown and Bridge (EnvisionTEC) und dem Harz E-Shell 600 (EnvisionTEC) wurden zunächst die Auflösungsgrenzen des Druckers ermittelt sowie Komponenten für die Realisierung eines mikrofluidischen Druckkopfes prozessiert. Bei den Komponenten handelt es sich zum einen um Geometrien, die beispielsweise als Mischeinheit im Kanal dienen können und des Weiteren um senkrechte Kanäle die Biotinten führen können, sowie um Kanäle, die als Zuläufe für den Hauptkanal des mikrofluidischen Druckkopfs dienen können. Die Eigenschaften und die technische Realisierbarkeit der gedruckten Objekte wurden eruiert. Dabei wurden die jeweiligen Geometrien und Kanalöffnungen vermessen, große Aspektverhältnisse der Geometrien untersucht und die Durchgängigkeit der Kanäle geprüft. Zukünftig können die prozessierten Komponenten für einen mikrofluidischen Druckkopf variabel kombiniert werden und auf dieser Basis weiterführende Experimente stattfinden. / 3D printing is an essential part of biofabrication. For example, geometries are built up layer by layer using bio-inks and a suitable 3D printing process. New options are given by the fabrication of a microfluidic print head. The design of microfluidic print heads creates the possibility of mixing multiple materials inside the print head and thus start printing certain mixing ratios. The resolution limits of the DLP-SLA printer Vida HD Crown and Bridge (EnvisionTEC) using the resin E-Shell 600 (EnvisionTEC) were first determined and components for the layout of a microfluidic print head were processed. The components are, on one hand, geometries that can serve as a mixing device inside the channel, and on the other hand, vertical channels that can carry bio-inks and channels that serve as inlets for the main channel of the microfluidic print head. The properties of the printed objects were examined, the respective geometries and channel openings were measured, large aspect ratios of the geometries were examined and the consistency of the channels investigated. In future, the processed components for a microfluidic print head can be combined variably and further experiments can take place on this basis.
7

Simulation der Kariesentfernung an 3D-gedruckten Molaren: Analyse der Reliabilität und der Validität / Simulation of caries removal on 3D-printed molars: Analysis of reliability and validity

Kurum, Tamer January 2022 (has links) (PDF)
In der vorliegenden Studie wurde an 50 3D-gedruckten Molaren mit einer konstruierten Referenzkaries das Ausmaß der vollständigen Kariesentfernung flächenabhängig überprüft. Die untersuchten Zähne wurden mit einer simulierten, standardisierten und mehrflächigen Karies versehen. Studierende der Zahnmedizin haben die Karies entfernt, die Kavität mit einer Aufbaufüllung versorgt und die Zähne für eine Vollkrone präpariert. Um die Kariesentfernung zu bewerten, wurden DVT-Aufnahmen und dreidimensionale Scans angefertigt. Aus den DVT-Datensätzen im DICOM-Format wurden die Aufbaufüllungen der Zähne mithilfe digitaler Bildverarbeitung segmentiert und als eigenständige 3D-Modelle dargestellt. Anschließend erfolgte die Überlagerung der Aufbaufüllungen auf den Referenzzahn aus der Konstruktionsdatei der Zähne. Mit der Konstruktionssoftware Autodesk Fusion 360 wurden die Aufbaufüllungen in Volumenkörper umgewandelt und mit der Karies des Referenzzahnes verglichen. Da sich die Aufbaufüllungen mit der Referenzkaries überschneiden, konnte die Software mit ihrer Teilungsfunktion nicht überschneidende Teile separieren. Abhängig von der Lage der Kavität, in der sich die überschüssigen Volumenkörper befanden, wurden jene als Restkaries oder überexkavierte Zahnhartsubstanz identifiziert. Die gemessenen Volumina von Restkaries ergaben, dass an der distalen Zahnfläche im Vergleich zur bukkalen und okklusalen signifikant mehr Karies verblieben war. Ein weiterer signifikanter Unterschied konnte zwischen mesial und bukkal, jedoch nicht zwischen mesial und okklusal festgestellt werden. Bei der Überexkavation gab es zwischen den Zahnflächen keine Unterschiede. Die Ergebnisse zeigten, dass die Kariesentfernung an den approximalen Zahnflächen für die Studierenden eine höhere manuelle Herausforderung darstellte. Neben der volumetrischen Vermessung ermöglichte die dreidimensionale Visualisierung von Restkaries und der überexkavierten Zahnhartsubstanz eine objektive Bewertung des Behandlungsergebnisses für die Studierenden und deren Ausbilder. Besonders der Vergleich mit einer Referenz schaffte eine valide und nachvollziehbare Beurteilung der Kariesübung an 3D-gedruckten Zähnen. / In the present study, the extent of complete caries removal was checked on 50 3D-printed molars with a constructed reference caries depending on the tooth surface. The examined teeth were created with a simulated, standardized and multi-surface caries. Dental students removed the caries, filled the cavity with a buildup filling and prepared the teeth for a crown. To assess caries removal, CBCT and three-dimensional scans were taken. From the DVT datasets in DICOM format, the buildup fillings of the teeth were segmented using digital image processing and displayed as 3D models. Then the buildup fillings were matched with the reference tooth from the design file of the teeth. With the Autodesk Fusion 360 design software, the buildup fillings were converted into solids and compared to the caries of the reference tooth. Because the buildup fillings overlap with the reference caries, the software was able to separate non-overlapping parts with its splitting function. Depending on the location of the cavity in which the solids were located, those were identified as residual caries or over-excavated tooth structure. The measured volumes of residual caries showed that significantly more caries was left on the distal tooth surface compared to the buccal and occlusal. Another significant difference was found between mesial and buccal, but not between mesial and occlusal. There were no significant differences in overexcavation between the tooth surfaces. The results showed that caries removal on the approximal tooth surfaces is a higher manual challenge for the students. In addition to volumetric measurement, the three-dimensional visualization of residual caries and over-excavated tooth structure enabled an objective evaluation of the treatment result for the students and their trainers. Especially the comparison with a reference allowed a valid and comprehensible assessment of the caries exercise on 3D-printed teeth.
8

Enhancement of geometric complexity and predictability of melt electrowriting for biomedical applications / Fortentwicklung von geometrischer Komplexität und Kalkulierbarkeit des Melt Electrowriting für biomedizinische Anwendungen

Hrynevich, Andrei January 2021 (has links) (PDF)
This thesis encompasses the development of the additive manufacturing technology melt electrowriting, in order to achieve the improved applicability in biomedical applications and design of scaffolds. Melt electrowriting is a process capable of producing highly resolved structures from microscale fibres. Nevertheless, there are parameters influencing the process and it has not been clear how they affect the printing result. In this thesis the influence of the processing and environmental parameters is investigated with the impact on their effect on the jet speed, fibre diameter and scaffold morphology, which has not been reported in the literature to date and significantly influences the printing quality. It was demonstrated that at higher ambient printing temperatures the fibres can be hampered to the extent that the individual fibres are completely molten together and increased air humidity intensifies this effect. It was also shown how such parameters as applied voltage, collector distance, feed pressure and polymer temperature influence the fibre diameter and critical translation speed. Based on these results, a detailed investigation of the fibre diameter control and printing of scaffolds with novel architectures was made. As an example, a 20-fold diameter ratio is obtained within one scaffold by changing the collector speed and the feed pressure during the printing process. Although the pressure change caused fibre diameter oscillations, different diameter fibres were successfully integrated into two scaffold designs, which were tested for mesenchymal stromal cell suspension and adipose tissue spheroid seeding. Further design and manufacturing aspects are discussed while jet attraction to the printed structures is illuminated in connection with the fibre positioning control of the multilayer scaffolds. The artefacts that appear with the increasing scaffold height of sinusoidal laydown patterns are counteracted by layer-by-layer path adjustment. For the prediction of a printing error of the first deposited layer, an algorithm is developed, that utilizes an empirical jet lag equation and the speed of fibre deposition. This model was able to predict the position of the printing fibre with up to ten times smaller error than the of the programmed path. The same model allows to qualitatively assess the fibre diameter change along the nonlinear pattern as well as to indicate the areas of the greatest pattern deformation with the growing scaffold height. Those results will be used in the later chapters for printing of the novel MEW structures for biomedical applications. In the final chapter the concept of multimodal scaffold was combined with the suspended fibre printing, for the manufacturing of the MEW scaffolds with controlled pore interconnectivity in three dimensions. Those scaffolds were proven to be a promising substate for the control of the neurite spreading of the chick DRG neurons. / Diese Arbeit umfasst die Entwicklung der additiven Fertigungstechnologie Schmelzelektroschreiben, um die verbesserte Anwendbarkeit in biomedizinischen Anwendungen und die Konstruktion von Gerüsten zu erreichen. Schmelzelektroschreiben ist ein Verfahren, das in der Lage ist, hochaufgelöste Strukturen aus mikroskaligen Fasern zu erzeugen. Dennoch gibt es Parameter, die den Prozess beeinflussen, und es ist nicht klar, wie sie sich auf das Druckergebnis auswirken. In dieser Arbeit wird der Einfluss der Verarbeitungs- und Umweltparameter mit der Auswirkung auf deren Einfluss auf die Polymerstrahlgeschwindigkeit, den Faserdurchmesser und die Gerüstmorphologie untersucht, was bisher in der Literatur nicht berichtet wurde und die Druckqualität wesentlich beeinflusst. Es konnte gezeigt werden, dass bei höheren Umgebungstemperaturen die Entstehung von zylindrischen Fasern soweit behindert werden können, dass die einzelnen Fasern vollständig zusammengeschmolzen werden und eine erhöhte Luftfeuchtigkeit diesen Effekt verstärkt. Es wurde auch gezeigt, wie solche Parameter wie angelegte Spannung, Kollektorabstand, Vorschubdruck und Polymertemperatur den Faserdurchmesser und die kritische Translationsgeschwindigkeit beeinflussen. Basierend auf diesen Ergebnissen, wurde eine detaillierte Untersuchung der Faserdurchmessersteuerung durchgeführt und Gerüsten mit neuartigen Architekturen wurden gedruckt. Als Beispiel wird ein 20-fach Durchmesserverhältnis innerhalb eines Gerüstes durch die Änderung der Kollektorgeschwindigkeit und des Vorschubdrucks während eines Druckvorgangs erreicht. Obwohl die Vorschubdruckveränderung spürbare Oszillationen des Faserdurchmessers verursachte, wurden Fasern mit unterschiedlichen Durchmessern erfolgreich in zwei Scaffoldmuster integriert, die für mesenchymale Stromazell und L929 Zellsuspension und die Aussaat von Fettgewebe-Sphäroiden getestet wurden. Weitere Design- und Herstellungsaspekte werden diskutiert, während die Polymerstrahlanziehung auf die gedruckten Strukturen in Verbindung mit der Faserpositionierungssteuerung der mehrschichtigen Scaffolds beleuchtet wird. Den Artefakten, die mit zunehmender Gerüsthöhe sinusförmiger Ablagemuster auftreten, wird durch schichtweise Anpassung von Verfahrweg des Kollektors entgegengewirkt. Für die Vorhersage eines Druckfehlers der ersten abgelegten Schicht wurde ein Algorithmus entwickelt, der die empirischen Zusammenhänge zwischen Kollektorgeschwindigkeit, Nachlauf, und die Geschwindigkeit der Faserablage verwendet. Dieses Modell war in der Lage die Position der gedruckten Faser mit einem bis zu zehnmal kleinerem Fehler als die Position auf dem programmierten Pfad vorherzusagen. Dasselbe Modell erlaubt es, die Änderung des Faserdurchmessers entlang des nichtlinearen Musters qualitativ zu bewerten und die Bereiche mit der größten Musterdeformation mit zunehmender Gerüsthöhe anzuzeigen. Diese Ergebnisse werden in anderen Kapiteln für den Druck der neuartigen MEW-Strukturen für biomedizinische Anwendungen verwendet. Im letzten Kapitel wurde das Konzept des multimodalen Gerüstes mit dem Druck von hängenden Fasern kombiniert, um MEW-Gerüste mit kontrollierter Porenvernetzung in drei Dimensionen herzustellen. Diese Gerüste erwiesen sich als vielversprechendes Substrat für die Kontrolle der Neuritenausbreitung der Nervenzellen aus Spinalganglien.
9

Etablierung eines neuen Lehrkonzeptes für die Schienung von parodontal gelockerten Zähnen mithilfe des 3D-Druckverfahrens / Establishment of a new teaching method for periodontal splinting using the 3D printing process

Rehling, Sören Alexander January 2023 (has links) (PDF)
Im präklinischen Ausbildungsabschnitt des Zahnmedizinstudiums sollen die Studierenden möglichst umfassend und vielseitig auf die Behandlung von Patienten vorbereitet werden. Bislang zählt die Schienung parodontal gelockerter Zähne nicht zum Ausbildungsspektrum und es gibt kein Übungsmodell, mit welchem diese Art der Versorgung erlernt werden könnte. Ziel dieser Studie war es, Zähne für ein Übungsmodell zu entwickeln, dieses mithilfe des 3D-Druckes herzustellen, sowie zusätzlich die Handhabung von verschiedenen Schienungsmaterialien von ungeübten Behandlern bewerten zu lassen. Es wurden parodontal gelockerte Zähne digital designt und mithilfe eines Stereolithographie 3D-Druckers gedruckt. Insgesamt 43 Studierende des siebten Fachsemesters nahmen im Rahmen des Parodontologiekurses freiwillig an der Studie teil. Es wurden pro Teilnehmer zwei Garnituren Zähne jeweils mit dem Material everStick Perio (GC Dental) und dem Material Ribbond Ultra (Ribbond Inc.) geschient. Die Bewertung der gedruckten Übungszähne sowie der zwei Schienungsmaterialien durch die Teilnehmer erfolgte mithilfe eines Fragebogens unter Nutzung der Schulnoten von 1 (sehr gut) bis 6 (ungenügend). Die geschienten Modelle wurden gescannt und digital verglichen. Die Schienungsübung wurde insgesamt als „gut“ empfunden. Die Realitätstreue der Zahnlockerungen sowie die Repositionierung der Zähne in den Zahnbogen wurden mit der Note „befriedigend“ bewertet. Das Material everStick Perio bekam in der Handhabung die Note „befriedigend“, das Material Ribbond Ultra die Note „gut“. Der Lerneffekt der Übung wurde mit der Note „gut“ bewertet, wobei die Teilnehmer ihre eigenen Fähigkeiten vor dem Kurs als „mangelhaft“ und nach dem Kurs als „gut“ bewerteten. Die digitale Auswertung der geschienten Modelle ergab keinen signifikanten Unterschied zwischen den einzelnen Gruppen, welche sich nach Schienungsmaterial, Erst- oder Zweitversuch der Schienung sowie den einzelnen geschienten Zähnen aufgliederten. Die Anwendbarkeit dieses Trainingskonzeptes wurde bestätigt, da sich aus Sicht der Studierenden ein positiver Lerneffekt zeigte. / In preclinical dental education, students need to be sufficiently prepared for treating patients. Until now, there is no model available for learning the treatment of periodontal splinting. In this study, we used 3D printing to produce artificial teeth with variable degrees of mobility and compared the usage of two different splinting materials by unexperienced practitioners. Teeth with degrees of mobility were digitally designed and printed using the stereolithography 3D printing process. 43 dentistry students in the fourth year participated in this study. Each student had to splint two sets of teeth using the splinting materials Ribbond Ultra (Ribbond, Inc.) and everStick Perio (GC Dental). The study model and the splinting materials were evaluated through a digital questionaire with school grades from 1 (very good) to 6 (insufficient). The splinted teeth were digitally scanned and compared with an ideally splinted study model. The splinting practice was overall rated with „good“. The degrees of mobility compared to a clinical situation and the repositioning of the teeth were answered with „satisfactory“. The material everStick Perio was „satisfactory“, the material Ribbond Ultra was „good“. The overall learning effect was „good“, whereby the participants described their ability to splint teeth before the course as „inadequate“ and after the course as „good“. The digital comparison of the splinted models showed no significant difference between the splinting materials. There was also no significant difference between the first and second attempt of splinting and no differences between the teeth. The applicability of this training model was confirmed as the students experienced a learning success for periodontal splinting.
10

3D-gedruckte Kronen in der studentischen Lehre zum Erlernen der Passungsoptimierung / 3D printed crowns in dental education for training of fitment optimization

del Hougne, Frank Michael January 2024 (has links) (PDF)
71 Studierende nahmen am Universitätsklinikum Würzburg in der Abteilung für Zahnärztliche Prothetik an einem freiwilligen Übungsseminar zum Aufpassen von Kronen mit Störstellen, die im 3D-Druckverfahren hergestellt wurden, teil. Das Übungsseminar fand an zwei Terminen statt. Zum Identifizieren der Störstellen standen Xantopren und Okklusionsspray zur Verfügung. Nach dem praktischen Teil der Übung wurde ein Fragebogen ausgefüllt. Zusätzlich wurden die aufgepassten Kronen mittels Laborscanner digitalisiert und mit einer Krone ohne Störstellen überlagert. Dadurch konnten positive und negative Oberflächenabweichungen für die Bereiche der Störstellen sowie der Gesamtinnenfläche der Kronen ermittelt werden. Die flächenbezogenen Abweichungswerte zeigten einen signifikanten Lernerfolg – gemessen anhand der Passungsparameter - zwischen den beiden Terminen des Übungsseminars. Hierbei erreichten Kronen, die mit Okklusionsspray aufgepasst wurden, signifikant geringere flächenbezogene Abweichungswerte im Vergleich zu Kronen, die mit Xantopren aufgepasst wurden. Die Auswertung der mit Schulnoten skalierten Fragen ergab signifikante Unterschiede bei der Bewertung der Härte, eines realitätsnahen Gefühls beim Einschleifen bzw. beim Aufpassen und Details wie Randschluss. Beim Vergleich der Aufpassmethoden im Fragebogen ergaben die Einfachheit beim Aufpassen, das Identifizieren der Störstellen und das präferierte Material signifikante Unterschiede. Der subjektive Lernerfolg mit den Materialien zeigte ebenfalls signifikante Unterschiede. Insbesondere die Materialeigenschaften und die Randgenauigkeit der Druckkronen wurden häufig kritisiert, die schnelle und einfache Möglichkeit zur Herstellung von Übungsmaterialien sowie deren Reproduzierbarkeit wurden von den Studierenden hingegen begrüßt. / 71 students participated at the Department of Prosthetics of the University of Würzburg in a voluntary training course for fitment optimization of 3D printed crowns with implemented areas of interference. The training course was split into two sessions. Xantopren and a powder spray were utilized to identify interferences. After completing the practical part of the training course students answered a questionnaire. The adapted crowns were digitalized with a laboratory scanner and matched with a crown without interferences. Thus, positive and negative surface deviations were identified for both the areas with interferences and the crowns’ entire inner surface. The comparison of surface deviations between both sessions of the training course revealed a significant learning outcome. Crowns adapted with powder spray had significantly lower surface deviations than crowns adapted with Xantopren. The questionnaire, scaled with school grades, revealed significant differences for evaluation of the crowns’ hardness, realism of the feeling when removing interferences und adaption of the crowns, and details such as marginal fit. When comparing both materials utilized for fitment optimization, the following aspects revealed significant differences: ease for fitment optimization, identification of interferences and preferred material. The subjective learning outcome with both materials revealed significant differences as well. Material properties and accuracy of the crowns’ edges were criticized by the students, however, students appreciated the ease, speed and reproducibility of manufacturing the crowns.

Page generated in 0.0343 seconds