Sobre o comportamento estrutural e o dimensionamento de lajes mistas de aço e concreto com armadura adicional / On the structural behavior and the design of composite slabs with additional reinforcement

Luiz Gustavo Fernandes Grossi 25 October 2016 (has links)
Usualmente, em situações práticas de projeto de lajes mistas, procura-se uniformizar ao máximo a espessura das fôrmas de aço, normalmente por razões econômicas (produção em larga escala). Entretanto, em alguns casos, há a necessidade de se especificarem algumas fôrmas com maior espessura, solução essa pouco competitiva no mercado brasileiro. Uma alternativa economicamente interessante em relação ao aumento de espessura é a inserção de armadura adicional, mantendo-se assim a espessura padrão (em geral 0,80 mm) e obtendo-se aumento da área de aço por meio de vergalhões. No entanto, por se tratar de uma solução inusual, o comportamento estrutural das lajes mistas com armadura adicional e seus critérios e diretrizes de dimensionamento não são previstos em normas e manuais técnicos: a ABNT NBR 8800 (2008, p. 226) e o Eurocode 4 (2004, p. 104) mencionam que, caso haja armadura para resistir ao momento fletor positivo, a formulação apresentada deverá ser adequadamente ajustada, mas não apresentam os respectivos critérios e equacionamentos. O ANSI/ASCE 3-91 (1992), o CSSBI S2-2008 (2008) e o ANSI/SDI C-2011 (2011) não mencionam a possibilidade de armadura adicional. Diante desse cenário, investigou-se o comportamento estrutural de lajes mistas com vergalhões e, por meio de uma extensão matemática das formulações já existentes para o caso sem armadura, foram propostos critérios de dimensionamento para os estados-limites últimos (momento fletor e cisalhamento longitudinal) e de serviço (deslocamento vertical). Foram realizados ensaios de flexão em doze protótipos de lajes mistas de dimensões usuais, sendo oito sem barras adicionais e quatro com, variando-se as dimensões (altura e vão, conforme Eurocode 4 (2004)) e com quatro taxas de armadura. A partir desses resultados, pôde-se analisar o comportamento estrutural dos protótipos com armadura adicional, os quais apresentaram ductilidade e capacidade consideravelmente maiores que as correspondentes lajes sem as barras. Por fim, também foram validadas as formulações referentes ao cisalhamento longitudinal (extensões do Método m-k e do Método da Interação Parcial) e ao deslocamento vertical, para os casos mais usuais. / Usually, on the design of composite slabs with profiled steel decking, it is tended to standardize as much as possible the thickness of the steel decking, generally because of economic reasons (large-scale production). Nevertheless, in a few cases it must be necessary to specify thicker steel decking, which is not a competitive solution in the Brazilian market. An economic alternative regarding the increase of thickness is the insertion of additional bottom reinforcement, thus, keeping the standard thickness (in general 0.80 mm) and obtaining the steel area increment through rebars. Notwithstanding, since that is an unusual solution, the structural behavior of composite slabs with additional reinforcement, their criteria and design guidelines are not provided in standards and technical manuals: ABNT NBR 8800 (2008) and Eurocode 4 (2004) state that, if there are additional bars to resist positive bending moment, the formulation should be adapted, however they do not present the respective criteria and equating. CSSBI S2-2008 (2008), ANSI/ASCE 3-91 (1992) and ANSI/SDI C-2011 (2011) do not mention the possibility of using additional reinforcement. In this scenario, the structural behavior of composite slabs with rebars was investigated and, through a mathematic extension of the formulation already used to the unreinforced situation, design criteria were proposed for the ultimate (flexure and longitudinal shear) and serviceability (deflection) limit states. In addition, flexure tests were carried out in twelve composite slabs with usual dimensions, eight of those without additional bars and four with, following the recommendations by Eurocode 4 (2004) about the variation of the dimensions (height and span), with the latter having four reinforcement rates. With the results of those tests, the structural behavior of the reinforced prototypes was analysed, which have showed considerably higher ductility and resistance when compared to those with the unreinforced ones. Finally, the formulations for the usual cases related to longitudinal shear (extensions of the m-k Method and the Partial Interaction Method) and deflection were validated.
22

Vigas mistas com laje de concreto e perfis laminados tipo I: análise comparativa do comportamento estrutural entre conectores / Composite beams with reinforced concrete slab and rolled I beam: comparative analysis of the structural behavior of connectors

RIBEIRO NETO, Juliano Geraldo 19 March 2010 (has links)
Made available in DSpace on 2014-07-29T15:03:41Z (GMT). No. of bitstreams: 1 Juliano Geraldo Ribeiro Neto.pdf: 2086855 bytes, checksum: 3b65b93d36838091f2c1204a03908f1c (MD5) Previous issue date: 2010-03-19 / Among the many structural and building systems, it could be highlighted a system that is a mix of steel-concrete that allows the application of their structural and building advantages as whole. When dealing with metal structures, it was noticed some changes regarding the standards of the involved material due to its lack of availability; such measures do not always follow satisfactory structural procedures. This research aims to develop a comparative study about the technical behavior of mixed steel-concrete from three different types of shear connectors (U, U and L cold formed laminated), analyzing their connectors structural behavior when associated with steel beams (Type I rolled and concrete slab). There were three direct shear tests for each type of connector, resulting in a total of nine pieces, and six trials (simply supported composite beams) to evaluate the positive bending moment region. The results indicated that the direct shear behavior between the types of connectors had important and different outcomes; however, they didn t affect significantly the average resistance of the bending mixed beams. Such beams showed considerable results regarding their deflection and deformation performance due to their connectors stiffness. / Dentre os diversos sistemas estruturais e construtivos existentes, destacam-se os sistemas formados por elementos mistos aço-concreto, cuja combinação de perfis de aço e concreto visa aproveitar as vantagens de cada material, tanto em termos estruturais como construtivos. Um fato corriqueiro que pode ser observado na execução de obras metálicas é a substituição de perfis especificados em projeto por outros equivalentes. Essa substituição, muitas vezes motivada pela falta do material especificado, nem sempre atende a uma equivalência de comportamento estrutural satisfatória. Neste trabalho é abordado um estudo comparativo do comportamento estrutural de vigas com seção mista aço-concreto, para três diferentes tipos de conectores de cisalhamento em perfil U laminado, U e L formados a frio. O objetivo é estudar o comportamento estrutural desses conectores associados a vigas metálicas em perfil I laminado e laje de concreto. Para cada tipo de conector foram realizados três ensaios de cisalhamento direto, resultando num total de nove peças, além de seis ensaios em vigas mistas simplesmente apoiadas para avaliação da região de momento fletor positivo. Os resultados obtidos indicaram que o comportamento ao cisalhamento direto entre os diferentes tipos de conectores apresentam significativa diferença, entretanto não influenciaram significativamente na resistência média das vigas mistas à flexão. Estas porém, apresentaram diferenças consideráveis de deflexões e deformações em virtude das diferenças de rigidez dos conectores.
23

Análise teórico-experimental de pisos mistos de pequena altura / Experimental and theorical analysis of composite shallow floors

Juliana Teodoro Friedrich 13 August 2012 (has links)
O piso misto usual é formado pela laje mista, de aço e concreto, apoiada na mesa superior da viga metálica. No piso misto de pequena altura, a laje mista se apoia na mesa inferior da viga, diminuindo assim a altura total do piso. A forma de aço, utilizada nesse sistema, tende a ser três vezes mais alta, que as formas de aço usuais. No Brasil não há uma forma de aço para uso nos sistemas mistos de pequena altura, comercializada. Este estudo trata do desenvolvimento de uma forma de aço trapezoidal para pisos mistos de pequena altura. Foi desenvolvida uma geometria de forma de aço trapezoidal com mossas estampadas nas laterais. Foram realizados ensaios experimentais com modelos de lajes mistas, confeccionados com a forma de aço desenvolvida no presente estudo. Esses ensaios visaram avaliar a resistência e o comportamento de lajes mistas fabricadas com a forma desenvolvida. A geometria da forma de aço e das mossas apresentaram um bom comportamento frente aos esforços cisalhantes, com resistências comparáveis as formas de aço comercializadas, mostrando que podem ser utilizadas em trabalhos futuros. / The usual composite floor is formed by the composite slab, of steel and concrete, supported on the top flange of the steel beam. On the shallow floor systems, the steel beams are contained within the depth occupied by the floor. The steel form steel used in this composite shallow floor systems is around three times higher than usual forms of steel decking. In Brazil there is not a form of steel for use in shallow floor systems, marketed. This study concerns the development of a steel decking to shallow floor systems. Developed a geometry shape of trapezoidal steel and embossements on the sides. Experimental tests were conducted with composite slabs, made of steel the shape developed in this study. These tests were intended to assess the strength and behavior of composite slabs made with the developed form. The geometry of the steel form and embossements showed good behavior against shearing efforts, forms with resistances comparable steel deckings marketed, showing that may be used in future work.
24

Análise da viabilidade econômica do projeto estrutural de edifícios de múltiplos andares com estrutura de aço / Analysis of the economic viability of the structural design of multi-story buildings with steel structures

Rafael Tamanini Machado 20 August 2012 (has links)
O presente estudo traz uma revisão bibliográfica dos sistemas estruturais, da estabilidade e análise estrutural de edifícios de múltiplos andares com estrutura de aço e, ainda, do emprego de elementos mistos aço e concreto nesses sistemas, com ênfase às vigas mistas. É aplicável a duas áreas, a saber: acadêmica e prática. Na área acadêmica, contribui com informações que permitem iniciar linhas de pesquisas para diversos assuntos. Na área prática, através de exemplos, contribui com a análise da viabilidade do processo construtivo e estrutural. E por meio de instruções mínimas, contribui para o desenvolvimento de projetos de estruturas metálicas. A referida pesquisa é embasada na ABNT NBR 8800:2008 e, quando indispensável, nas normas ANSI/AISC 360-10 e EN 1994-1-1:2004. / The concerned study brings a literature review of structural systems, stability and structural analysis of multistory buildings with steel structures and also the use of steel-concrete composite elements in those systems, with emphasis on composite beams. It applies to two subjects, namely: academic and practical. In academics, it contributes with informations that allows you to start several lines of research. In the practice, through examples, it contributes with the assessment of the viability of the construction and structural process. And using minimal instructions, it contributes to the development of steel structure projects. The related research is based on the ABNT NBR 8800:2008 and, when necessary, on ANSI/AISC 360-10 and EN 1994-1-1:2004.
25

Análise da resposta dinâmica experimental de uma passarela tubular mista, aço-concreto, submetida ao caminhar humano. / Experimental analysis of dynamic response of a tubular composite steel-concrete footbridge, submitted to human walking.

José Eduardo Villarroel Zúñga 19 July 2011 (has links)
Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano. / This research has as main objective the development of a dynamical experimental investigation of a real structure a tubular composite steel-concrete footbridge. The structural system of this study corresponds to a footbridge composed by three spans (32,5m, 17,5m and 20,0m, respectively) and two overhangs (7,50m and 5,0m, respectively), spanning 82,5m. The investigated structural model is composed by a continuous tubular steel structure with welded connections supported by four double file steel columns. It is structurally composed of two plane trusses are intertwined by horizontal bracing set in upper and lower chord of the truss and slabs of concrete, forming effective composite with complete interaction. This structure is currently submitted to pedestrians and cyclists crossing. Experimental tests were carried out on the structural system and with the numerical results. For the numerical modeling, discretization techniques via finite element method were applied, based on the ANSYS program. The experimental results were analyzed according to the developed methodology, and a modal analysis was implemented to determine the dynamical properties: frequencies, mode shapes and modal damping ratio, while the structure results in terms of peak acceleration, was obtained and compared to the limit values proposed by several authors and design recommendations, for the structure performance by pedestrian walking regarding the acceptance criteria for human comfort.
26

Comportamento estrutural de vigas mistas de aço e concreto com protensão externa

Nelsen, Anna Carolina Haiduk 11 July 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:18Z (GMT). No. of bitstreams: 1 5306.pdf: 6510064 bytes, checksum: b7a3095b2eb1b62ba399cfe3a2684382 (MD5) Previous issue date: 2013-07-11 / Financiadora de Estudos e Projetos / This report investigates the structural behavior, procedures for analysis and design of externally prestressed steel-concrete composite beams. Based upon the requirements outlined in ABNT NRB 8800:2008 for conventional composite beams and in the literature review, a systematic procedure was developed to design of externally prestressed steel-concrete composite beams requested the positive bending moment. Was analyzed the main modes of global collapse, especially the ultimate limit state design (ELU), which may occur in this type of structure. Also, elaborated a parametric study aimed to analyze the influence of variation in the level of prestressing and the eccentricity of tendons, as well as the constructive methodology (pretensioning and posttensioning) adopted for the the prestressing steel profile that makes up the of steel-concrete composite beam. The parametric study showed that in both methods the predominant failure mode occurs in 2nd Stage of construction. In models of composite beams analyzed with application of pretensioned when the tendon is positioned above the bottom flange of the profile steel the failure mode occurred for the combined bending and axial compression .As for the composite beams evaluated with posttensioned, independent of the position of the tendon, the failure mode occurred in function of the bending moment more than the allowable flexural strength. However, it is noted that the level of prestressing can be adequately calculated to ensure that there is no loss of carrying capacity of the structure. It was also observed that regardless of the constructive methodology adopted, higher eccentricities result in higher bearing capacity for the steel beam, as exposed in the literature review. While in Brazil is largely unexplored, there was widespread interest in the international literature on the subject in question and their variances, giving rise to theoretical and experimental. Also been mentioned as potential applications in the design of new structures and the renovation and rehabilitation of existing structures. / O presente trabalho discorre sobre o comportamento estrutural, procedimentos de análise e dimensionamento de vigas mistas de aço e concreto protendidas externamente. Embasado nas prescrições expostas na norma ABNT NRB 8800:2008 para vigas mistas convencionais e na revisão bibliográfica, um procedimento de cálculo foi desenvolvido para o dimensionamento de vigas mistas de aço e concreto protendidas externamente e solicitadas a momento fletor positivo. Foram analisados os principais modos de colapso globais, com destaque nos estados limites de últimos (ELU), que podem ocorrer nesse tipo de estrutura. Além disso, elaborou-se um estudo paramétrico que teve como objetivo analisar a influência da variação do nível de protensão e da excentricidade dos cabos de protensão; bem como da metodologia construtiva (pré-tração e pós-tração) adotada para a protensão do perfil de aço que compõe a viga mista de aço e concreto. O estudo paramétrico demonstrou que em ambas as metodologias o modo de colapso predominante ocorre na 2ª Etapa de construção. Nos modelos de vigas mistas analisados com aplicação de pré-tração quando o cabo está posicionado acima da mesa inferior do perfil de aço o modo de falha ocorreu por flexo-compressão. Já para as vigas mistas avaliadas com pós-tração, independe da posição do cabo, ocorre em função do momento fletor solicitante superar o momento fletor resistente da seção. No entanto, observa-se que o nível de protensão pode ser adequadamente dimensionado de maneira que não provoque a perda da capacidade de suporte da estrutura. Observou-se ainda que independente da metodologia construtiva adotada, maiores excentricidades resultam em maior capacidade resistente para a viga de aço, corroborando os estudos expostos na revisão bibliográfica. Embora no Brasil seja pouco explorado, observou-se um amplo interesse na literatura internacional sobre o tema em questão e suas variâncias, dando origem a pesquisas teóricas e experimentais. Também se aponta como potencialidades de aplicação em projetos de novas estruturas bem como na recuperação e reabilitação de estruturas existentes.
27

Pilares mistos de aço e concreto parcialmente revestidos: comportamento isolado, inserção em galpões industriais e comparativos com pilares de sistemas estruturais usuais

Serafim, Jorge Augusto 16 May 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:19Z (GMT). No. of bitstreams: 1 5850.pdf: 3492179 bytes, checksum: a8bf8363cbcbb501bfa5251bc969c178 (MD5) Previous issue date: 2013-05-16 / Despite the great use in most developed countries, the composite structures have been little exploited in Brazil, including rare records the use of composite columns of steel and concrete partially coated in industrial sheds. The low-use leaves the impression of this being a structural solution viable. The aim of this work is to insert the composite columns of steel and concrete partially coated alternatively to the pillars of steel and precast, solutions commonly used in the composition of the structural system of industrial sheds. The development work was done to study the behavior of the isolated element and sizing criteria applicable, analysis of the structural design of systems where it can be employed and the phases of project highlighting, still, some steps involved in constructive phase of the industrial sheds. We analyzed the elements of 108 sheds with variation in the span between 20 to 50 m and height of 8 to 12 m. the porticos were designed considering coverage using steel beams with profile type I and type I section steel pillars, pillars of precast concrete with rectangular section, composite columns of steel and concrete partially coated consisting of metallic profile type I with filling of concrete between the tables. The porticoes were analyzed in 2nd order and scaled according to the specific Brazilian standards by comparing the results obtained between structural systems. Costs despite the difficulties have been raised for the central region of the State of São Paulo, where, after the composition were made comparisons between the solutions. The results obtained can realize that the use of composite columns of steel and concrete partially coated are perfectly viable with visa point economic values quite surprising, for the fact of being a solution less maid. The use of composite columns of steel and concrete partially coated is obviously viable as an alternative to the usual structural systems used in industrial sheds, comes in to advance contribution of Civil construction in General. / Apesar da grande utilização em países mais desenvolvidos, as estruturas mistas têm sido pouco exploradas no Brasil, inclusive com raros registros da utilização de pilar parcialmente revestido em galpões industriais. A pouca utilização deixa a impressão de esta não ser uma solução estrutural viável. O objetivo deste trabalho é inserir o pilar misto parcialmente revestido como alternativa aos pilares de aço e pré-moldados de concreto, soluções comumente empregados na composição do sistema estrutural de galpões industriais. Para o desenvolvimento do trabalho foi feito o estudo do comportamento do elemento isolado e dos critérios de dimensionamento aplicáveis, a análise da concepção estrutural dos sistemas onde possa ser empregado e das fases de projeto destacando, ainda, algumas etapas envolvidas na fase construtiva dos galpões. Foram analisados os elementos de 108 pórticos de galpão com variação do vão de 20 a 50 m e da altura de 8 a 12 m. Os pórticos foram projetados considerando cobertura utilizando-se vigas metálicas com perfil tipo I e, pilares metálicos de seção tipo I, pilares de concreto pré fabricado de seção retangular e, pilar misto parcialmente revestido constituído de perfil metálico tipo I com preenchimento de concreto entre as mesas. Os pórticos foram analisados em 2ª ordem e dimensionados de acordo com as normas brasileiras especificas comparando os resultados obtidos entre sistemas estruturais. Os custos apesar das dificuldades foram levantados para a região central do estado de São Paulo, onde, após a composição foram feitas as comparações entre as soluções. Pelos resultados obtidos pode-se perceber que a utilização dos pilares mistos de aço e concreto são perfeitamente viáveis com valores do ponto de visto econômico bastante surpreendentes pelo fato de ser uma solução pouco empregada. A utilização de pilares mistos de aço e concreto parcialmente revestidos é evidentemente viável como alternativa aos sistemas estruturais usuais utilizados em galpões industriais, vem contribuir em muito para o avanço da Construção Civil em geral.
28

Influência do comportamento das ligações na estabilidade de estruturas mistas de aço e concreto / Influence of the behavior of connections on the stability of concrete-steel composite structures

Pulido, Antonio Carlos 16 June 2014 (has links)
Made available in DSpace on 2016-06-02T20:09:21Z (GMT). No. of bitstreams: 1 6242.pdf: 8638338 bytes, checksum: 94fe90943d4b53e78099d6e565e290de (MD5) Previous issue date: 2014-06-16 / The objective of this work was to evaluate the influence of the rigidity of the beam-tocolumn connections as well as the transference of forces among the structural components in steel-concrete composite structures. to do this, data regarding the Moment vs. Rotation curve behavior of a concrete filled beam-to-column connection, previously evaluated on a different work was used for comparison. The experimental value of rigidity was inserted into models of plane frames and tridimensional models, in a way that the global stability parameters can be evaluated according to the rotational stiffness of the beam-to-column connections. In order to evaluate the stability, was led in consideration the ABNT NBR 8800:2008 Brazilian code recommendations. For the numeric simulations, the software SAP 2000® was used, in which it was simulated a plane frame model with ten floors, and also a tridimensional frame, varying the number of floors. Once constructed the numerical models, for the plane frame comparative analysis were performed study of the redistribution of forces, of consumption of steel and stability considering that the beam-to-column connections represented in the models, simulate the following situations regarding the system stiffness: rigid and semi-rigid connections and also ratios of experimental stiffness. For the tridimensional model, besides the variation of the stiffness connection the influence of number of floors on the parameters of stability and distribution of forces on structural elements was also analyzed in the present study. The results showed that the stiffness of the beam-to-connections alters the distribution of forces, and that the variation on the number of floors have influence on the global stability parameter. However, it is possible to design structures with semi-rigid beam-to-column connections respecting the normative limits for the parameters of stability and reducing the consumption of steel in the form of profiles. / O objetivo deste trabalho é avaliar a influência da rigidez das ligações viga-pilar no comportamento e na transferência de forças entre componentes estruturais de sistemas estruturados em elementos mistos de aço e concreto. Para isso, serão utilizados dados do comportamento Momento vs. Rotação de uma ligação viga-pilar misto preenchido já investigada experimentalmente. Os resultados experimentais de rigidez serão inseridos em modelos de pórticos planos e tridimensionais, de forma que os parâmetros de estabilidade global possam ser avaliados em função da rigidez da ligação viga-pilar. Para o estudo da estabilidade são consideradas as recomendações da norma brasileira de estruturas de aço e mistas ABNT NBR 8800:2008. Para as simulações numéricas foi utilizado o pacote computacional SAP 2000® no qual foi modelado um pórtico plano com dez pavimentos e um pórtico tridimensional, variando-se o número de pavimentos e a rigidez das ligações. Para o pórtico plano foram realizadas análises comparativas da distribuição de esforços, do consumo de aço e da estabilidade considerando que as ligações viga-pilar representadas no modelo simulem as seguintes situações quanto à rigidez: ligações rígida e semirrígida, cuja rigidez foi determinada experimentalmente, além de parcelas desta rigidez experimental. Para os pórticos tridimensionais, além da variação de rigidez, foi analisada a influência do número de pavimentos sobre os parâmetros de estabilidade e distribuição de esforços nos elementos estruturais. Os resultados mostraram que a rigidez das ligações altera a distribuição dos esforços e a variação no número de pavimentos influencia nos parâmetros de estabilidade global. No entanto, é possível conceber estruturas com ligações viga-pilar semirrígidas respeitando os limites normativos para os parâmetros de estabilidade e reduzindo o consumo de aço sob a forma de perfis.
29

Análise da resposta dinâmica experimental de uma passarela tubular mista, aço-concreto, submetida ao caminhar humano. / Experimental analysis of dynamic response of a tubular composite steel-concrete footbridge, submitted to human walking.

José Eduardo Villarroel Zúñga 19 July 2011 (has links)
Este trabalho de pesquisa apresenta como objetivo principal o desenvolvimento de investigação experimental dinâmica sobre estrutura real de uma passarela tubular mista aço-concreto. O sistema estrutural objeto deste trabalho corresponde a uma passarela composta por três vãos (32,5m, 17,5m e 20,0m, respectivamente) e dois balanços (7,50m e 5,0m, respectivamente), com comprimento total de 82,5m. A passarela com estrutura contínua de aço com as ligações soldadas se apoia em quatro pórticos também de aço. Estruturalmente está constituída por duas treliças planas que se interligam através de contraventamentos horizontais fixados na corda superior e inferior da treliça e lajes de concreto, formando um sistema misto com interação completa. A estrutura está submetida correntemente à travessia de pedestres e ciclistas. Testes experimentais foram realizados sobre o sistema estrutural e confrontados com resultados numéricos. Para a modelagem numérica do sistema são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa ANSYS. Os resultados experimentais são analisados de acordo com a metodologia desenvolvida, sendo realizada análise modal experimental para a determinação das propriedades dinâmicas: freqüências, modos e taxa de amortecimento, enquanto que os resultados da estrutura, em termos de aceleração de pico, são comparados com os valores limites propostos por diversos autores, normas e recomendações de projeto, para uma avaliação do desempenho da estrutura em relação a vibração quando solicitada pelo caminhar dos pedestres no que diz respeito a critério para conforto humano. / This research has as main objective the development of a dynamical experimental investigation of a real structure a tubular composite steel-concrete footbridge. The structural system of this study corresponds to a footbridge composed by three spans (32,5m, 17,5m and 20,0m, respectively) and two overhangs (7,50m and 5,0m, respectively), spanning 82,5m. The investigated structural model is composed by a continuous tubular steel structure with welded connections supported by four double file steel columns. It is structurally composed of two plane trusses are intertwined by horizontal bracing set in upper and lower chord of the truss and slabs of concrete, forming effective composite with complete interaction. This structure is currently submitted to pedestrians and cyclists crossing. Experimental tests were carried out on the structural system and with the numerical results. For the numerical modeling, discretization techniques via finite element method were applied, based on the ANSYS program. The experimental results were analyzed according to the developed methodology, and a modal analysis was implemented to determine the dynamical properties: frequencies, mode shapes and modal damping ratio, while the structure results in terms of peak acceleration, was obtained and compared to the limit values proposed by several authors and design recommendations, for the structure performance by pedestrian walking regarding the acceptance criteria for human comfort.